0% found this document useful (0 votes)
194 views3 pages

Spelling Bee Light Plot

The document contains a legend and lighting plot for a stage production. The legend lists various lighting fixtures that will be used, including ERS fixtures, fresnels, an LED PAR, and moving lights. The lighting plot diagram then shows the placement of numbered lighting instruments in a grid with 4 pipe batten positions and notes regarding circuiting and substitutions.

Uploaded by

Edward Hansen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
194 views3 pages

Spelling Bee Light Plot

The document contains a legend and lighting plot for a stage production. The legend lists various lighting fixtures that will be used, including ERS fixtures, fresnels, an LED PAR, and moving lights. The lighting plot diagram then shows the placement of numbered lighting instruments in a grid with 4 pipe batten positions and notes regarding circuiting and substitutions.

Uploaded by

Edward Hansen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

VECTORWORKS EDUCATIONAL VERSION LEGEND

6x9 ERS @ 500w

Selecon Pacific Zoom


23-50deg @ 575w

6" Fresnel @ 500w

8" Fresnel @ 1kw

Elation Fuze Wash Z120


@ 157w

RGBW LED PAR @ 60w

93

1 1 PIPE
R-351

13 13 2 12 1 11 11

1 2 3 4 5 6 7 2 PIPE
R-351 R-351 R-351 R-351 R-351

R-3208
1 82
91
16 16 15 14 101 14
R-3208 GENERAL NOTES
1 2 3 4 5 6 7 8 3 PIPE 1. Circuiting per production electrician.
2. No substitutions without the written approval of the
designer.
R-351 R-351 R-351 R-351 R-3208 R-351 3. Refer to hookup for all final color and template info.
83
L-218

1 102

R-4860
R-4860

42 1 R-3208 1 41

4 PIPE

R-60

R-60
R-60

R-60
34 1 23 2 33 3 23 4 5 21 6 32 7 21 8 31
TYPICAL NOTATION

L-202 COLOR
36º
PURPOSE

PURPOSE
1 UNIT NUMBER

1 CHANNEL

R-4860
R-4860

42 2 2 41 1 PRELIMINARY 9/8/2019
2 SHOP ORDER REVISION 9/10/2019
L-201 3 LOS ANGELES FINAL 9/18/2019
81 4 TECH REVISION 9/27/2019

5 PIPE

R-60

R-60
R-60

R-60

38 1 24 2 37 3 24 4 5 6 7 22 8 36 9 22 10 35 REV # REVISION DATE

N/C THE 25th ANNUAL PUTNAM


92 COUNTY SPELLING BEE
L-251

L-251
1 78 71 1
1 2 3 4 PIPE 5A
R-4860

R-4860
42 3 3 41
64 63 62 61
77 R-55 R-55 R-55 R-55 R-55 R-55 R-55 R-55 R-55 R-55 72
75 74
L-251

L-251
1 76 2 3 4 5 6 7 8 9 10 11 73 12 6 PIPE
2 56 53 2 56 53 55 52 54 51 1 54 51 2
PRODUCED BY
L-251 L-251 L-251 L-251 USC MUSCIAL THEATRE REPERTORY

DIRECTED BY: ………………………………… .………TYLER ELLIS


SCENERY DESIGNED BY: …………………… .……JORDAN FOX
LIGHTING DESIGNED BY: ……………………EDWARD HANSEN
ASST. LIGHTING DESIGNER: ……… ..……..ERICA AMMERMAN
111 111 PRODUCTION ELECTRICIAN: …………………… ..JORDAN FOX

7 PIPE
MASSMAN THEATRE
1 2 LOS ANGELES, CA

R-68 R-68

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND CONSTRUCTION


SUGGESTIONS ONLY. IT DOES NOT REPLACE THE KNOWLEDGE AND
ADVICE OF A LICENSED STRUCTURAL ENGINEER. THE DESIGNER IS

A PIPE B PIPE C PIPE D PIPE E PIPE F PIPE G PIPE H PIPE J PIPE


UNQUALIFIED TO DETERMINE THE STRUCTURAL APPROPRIATENESS OF
THE DESIGN AND WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING OR USE.

PLATE:
SCALE: 1/2" = 1'0"

1
DRAWN: ESH

DATE: 9/27/2019

VERSION: 1.0 OF 3
1 LIGHT PLOT
1 Scale: 1/2" = 1'-0"
LIGHT PLOT
VECTORWORKS EDUCATIONAL VERSION
VECTORWORKS EDUCATIONAL VERSION LEGEND

6x9 ERS @ 500w

Selecon Pacific Zoom


23-50deg @ 575w

6" Fresnel @ 500w

8" Fresnel @ 1kw

Elation Fuze Wash Z120


@ 157w

RGBW LED PAR @ 60w

PIPE 5A
PIPE 1

PIPE 2

PIPE 3

PIPE 4

PIPE 5

PIPE 6

PIPE 7
GENERAL NOTES
1. Circuiting per production electrician.
2. No substitutions without the written approval of the
designer.
3. Refer to hookup for all final color and template info.

TYPICAL NOTATION

L-202 COLOR
36º
PURPOSE

PURPOSE
1 UNIT NUMBER

1 CHANNEL

1 PRELIMINARY 9/8/2019
2 SHOP ORDER REVISION 9/10/2019
3 LOS ANGELES FINAL 9/18/2019
4 TECH REVISION 9/27/2019

REV # REVISION DATE

THE 25th ANNUAL PUTNAM


COUNTY SPELLING BEE

PRODUCED BY
USC MUSCIAL THEATRE REPERTORY

DIRECTED BY: ………………………………… .………TYLER ELLIS


SCENERY DESIGNED BY: …………………… .……JORDAN FOX
LIGHTING DESIGNED BY: ……………………EDWARD HANSEN
ASST. LIGHTING DESIGNER: ……… ..……..ERICA AMMERMAN
PRODUCTION ELECTRICIAN: …………………… ..JORDAN FOX

MASSMAN THEATRE
LOS ANGELES, CA

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND CONSTRUCTION


SUGGESTIONS ONLY. IT DOES NOT REPLACE THE KNOWLEDGE AND
ADVICE OF A LICENSED STRUCTURAL ENGINEER. THE DESIGNER IS
UNQUALIFIED TO DETERMINE THE STRUCTURAL APPROPRIATENESS OF
THE DESIGN AND WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING OR USE.

PLATE:
SCALE: 1/2" = 1'0"

2
DRAWN: ESH

DATE: 9/27/2019

VERSION: 1.0 OF 3
1 CL SECTION
2 Scale: 1/2" = 1'-0"
CL SECTION
VECTORWORKS EDUCATIONAL VERSION
VECTORWORKS EDUCATIONAL VERSION LEGEND

6x9 ERS @ 500w

Selecon Pacific Zoom


23-50deg @ 575w

6" Fresnel @ 500w

8" Fresnel @ 1kw

Elation Fuze Wash Z120


@ 157w

RGBW LED PAR @ 60w

4'-0"

3'-1 3/4"

GENERAL NOTES
1. Circuiting per production electrician.
2'-0" 2. No substitutions without the written approval of the
designer.
3. Refer to hookup for all final color and template info.

OUTLINE INTERIOR OF
SCENIC ARCHWAY WITH
RGBW LED TAPE

6'-0"

TYPICAL NOTATION

L-202 COLOR
36º
PURPOSE

PURPOSE
1 UNIT NUMBER

121 122 1 CHANNEL

1 PRELIMINARY 9/8/2019
2 SHOP ORDER REVISION 9/10/2019
3 LOS ANGELES FINAL 9/18/2019
4 TECH REVISION 9/27/2019

REV # REVISION DATE

THE 25th ANNUAL PUTNAM


COUNTY SPELLING BEE

PRODUCED BY
USC MUSCIAL THEATRE REPERTORY

DIRECTED BY: ………………………………… .………TYLER ELLIS


SCENERY DESIGNED BY: …………………… .……JORDAN FOX
LIGHTING DESIGNED BY: ……………………EDWARD HANSEN
ASST. LIGHTING DESIGNER: ……… ..……..ERICA AMMERMAN
PRODUCTION ELECTRICIAN: …………………… ..JORDAN FOX

MASSMAN THEATRE
LOS ANGELES, CA

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND CONSTRUCTION


SUGGESTIONS ONLY. IT DOES NOT REPLACE THE KNOWLEDGE AND
ADVICE OF A LICENSED STRUCTURAL ENGINEER. THE DESIGNER IS
UNQUALIFIED TO DETERMINE THE STRUCTURAL APPROPRIATENESS OF
THE DESIGN AND WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING OR USE.

PLATE:
SCALE: 1/2" = 1'0"

3
DRAWN: ESH

DATE: 9/27/2019

VERSION: 1.0 OF 3
1 FRONT ELEVATION
3 Scale: 1/2" = 1'-0"