1 2 3 4 5
D6 R49
S1M 27K
+Battery
R18
R42 20K
1M Q18 D7 C17
KST5551 BZV55-C15
Phase 1 B
A Q19 C D8 A
D1 Q1 KST5551 GND GND R27 BZV55-C15
SS310 C12 R43 R24 51K +3.3V
100k 560 IC2
GND LM2903
6.8K
D9 1 8
R1 A
16
R25 7 R32 R33
GND GND +3.3V
SS8550 4.7K 100K
2
Q6
Phase 2 3K 3 6
Q7 3 C7 4 5
D2 VOUT R17 R41
Q2 SS8050 2
SS310 VIN C10 100K
1 C15 C11
R8 C18 GND
6.8K 47uF GND R34
R2 SS8550 HT7533-1 Q15 100K
Q5 IC3 GND GND
16 D11 SS8050 GND GND
GND +3.3V
R13 R26 R29
4.7K GND 1.2K 10K 100K
Phase 3 GND R30 D10
B D3 Green-LED B
SS310 Q3 GND GND GND GND R19
RED-LED 200 (Charging)
R35 R36
(Break/Fully charged) Q14 47K
R3 +Battery +3.3V 10K R22
SS8050 10K
16 GND 1K
R20
IC1
C LM2901
C2 R45
100uF 5.1K
R47
R48 1 14 Q16
Q13
GND 10K 2 13 SS8050
47K SS8050
R44 3 12 C6
27K R40
R31 20K 4 11
GND 5 10 GND GND GND
A 20K
C14
L1 R46 R39
100uH 3A D5 10K 9.1K 6 9 +3.3V R21
D4 R50 7 8 10K
SS310 SS310 C8 27K C13
+Battery R23 R38
6.8K Q17 100K R16
GND GND SS8050 200K D
C R14 R51 C
C3 5.6K 27K
R4 C16
C1 B
16 100uF GND GND R37
Q4 C5 SS8550 2.7K Q12
R28 Q9 GND GND SS8550
10K Q10
SS8050 Q11
R7 R5 GND GND SS8550
3X 0.47 Ohm D R10 R11
GND SS8550 5.6K 5.1K
C9 Q8 120K
R6 R12
R15 R9
4.7K 10K GND
+Battery
GND GND
GND GND
C4
+ 1
- 2
D GND D
12V/24V
TITLE:
Reverse Engineering of MPPT Wind Charge Controller REV: 1.0
Company: Mousa - Simple Projects Sheet: 1/1
Date: 2020-06-03 Drawn By: Mousa
1 2 3 4 5