Data Sheet HPL 50 1/2SF AST M2839: Black Polyethylene Jacket

This document provides specifications for an HPL 50-1/2SF black polyethylene jacket coaxial cable. It lists details on the inner conductor, dielectric, outer conductor, and jacket materials. It also specifies mechanical characteristics like minimum bending radii, tensile strength, and operating temperature range. Electrical characteristics include impedance, capacitance, attenuation, and power handling capabilities over a frequency range of 30 MHz to 3800 MHz. Testing is in accordance with various IEC standards.

Uploaded by

EugeneZarubin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views1 page

Data Sheet HPL 50 1/2SF AST M2839: Black Polyethylene Jacket

This document provides specifications for an HPL 50-1/2SF black polyethylene jacket coaxial cable. It lists details on the inner conductor, dielectric, outer conductor, and jacket materials. It also specifies mechanical characteristics like minimum bending radii, tensile strength, and operating temperature range. Electrical characteristics include impedance, capacitance, attenuation, and power handling capabilities over a frequency range of 30 MHz to 3800 MHz. Testing is in accordance with various IEC standards.

Uploaded by

EugeneZarubin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DATA SHEET AST

HPL 50‐1/2SF M2839


Black Polyethylene Jacket Page: 1/1

1 ‐ Inner Conductor : Copper ‐clad Aluminium


Diameter :3.60 ± 0.05 mm
2 ‐ Dielectric : Foam Polyethylene
Diameter : 9.0 ± 0.10 mm
Eccentricity : < 2%
3 ‐ Outer Conductor : Helically corrugated copper tube
Diameter over outer conductor : 12.10 ± 0.15 mm
Diameter inside bottom : 8.75 ± 0.15 mm
Section length : 3.0 ± 0.15 mm
4 ‐ Jacket : Black Polyethylene
Diameter : 13.40 ± 0.20 mm
5 ‐ Ink marking : Metric length
ACOME HYPERCELL COAX HPL 50‐1/2 SUPER FLEXIBLE M2839 LOT X lot N°

Mechanical Characteristics
Packaging : 500 meters Installation Bending radius : 25 mm ‐ Min.
Halogen content : IEC754‐1 Operating Bending radius : 50 mm ‐ Min.
Installation temperature range : ‐25°C / + 60°C Tensile Strength : 700 N
Operating temperature range : ‐40°C / + 85°C Bending moment at 90° :4.4 Nm
Weight approx : 181kg/km

Electrical Characteristics Operating frequency : 10 GHz


Impedance : 50 ± 1Ω   Peak power rating : 16 kW
Capacitance : 78 ± 1.5 pF/m Operating voltage : 1.27 kV RMS
Intermodulation IM3 (GSM‐UMTS) maxi : ‐158 dBc (‐163 dBc Test voltage : 2.6 kV RMS
typical)
Insulation Resistance : > 10000 MΩ.km
Velocity : 85%, Dielectric constant : 1.38, typical values
DC resistance : Inner conductor : < 2.90Ω /km
Screening effectiveness : > 120 dB
: Outer conductor : < 3.67Ω /km
Test methods are meeting the requirements of :
IEC60096‐0‐1,IEC61196‐1,IEC60966‐1
A tte nuation Power kW Attenuation Power kW
Frequency Frequency
db/10 0m @ 20 °C @ 40°C ‐A mbient T emp db/1 00m @ 2 0°C @ 40 °C ‐A mbient Temp
MH z MH z
T ypical Inner conductor : 100°C Typical Inner conductor : 100°C
30 1 .77 5.58 2000 16 .00 0 .61
80 2 .92 3.38 2200 16 .87 0 .58
150 4 .03 2.45 2300 17 .29 0 .56
450 7 .15 1.38 2400 17 .71 0 .55
824 9 .86 1.00 2500 18 .12 0 .54
900 1 0.34 0.95 3000 20 .12 0 .49
960 1 0.71 0.92 3300 21 .20 0 .47
1000 1 0.95 0.90 3400 21 .56 0 .46
1500 1 3.65 0.72 3500 21 .92 0 .45
1700 1 4.62 0.67 3600 22 .28 0 .43
1800 1 5.09 0.65 3800 22 .98 0 .41
1900 1 5.55 0.63

This technical specification is for reference only and is subject to change without notice

Edition :2009‐07‐15

DIVISION TELECOMMUNICATION‐52, rue du Montparnasse‐75014 PARIS‐France


Tel:+(33)1 42 79 14 00 ‐Fax(33) 1 42 79 15 00‐E‐mail:[email protected]

You might also like