© Siemens 2021

SENTRON • SIVACON • ALPHA

Low-Voltage Power
Distribution and Electrical
Installation Technology
Miniature Circuit Breakers

Catalog
Extract Edition
LV 10 10/2021 siemens.com/lowvoltage
© Siemens 2021

Innovative solutions for industrial


controls and power distribution
In ensuring smooth operation of digital production environments and in the construction and
operation of industrial or commercial buildings, the underlying power distribution and industrial
controls are decisive:

SIRIUS, SENTRON, SIVACON and ALPHA provide a broad portfolio of systems and components for this
purpose that can be used for standard-compliant, requirement-based electrification.

Efficient engineering tools and cloud-based solutions are part of the portfolio, which you can flexibly
adapt to your specific requirements over the entire value-added process.

We are there when you need us


Your personal contact can be found at
www.siemens.com/lowvoltage/contact

Catalog LV 10 · 10/2021 The products and systems described in this catalog are manufactured/
distributed under application of a certified quality management system
You will find the latest edition and all future editions in accordance with EN ISO 9001 (for the Certified Registration Nos., see
in the Siemens Industry Online Support at www.siemens.com/system-certificates/ep).
www.siemens.com/lowvoltage/catalogs The certificate is recognized by all IQNet countries.
Refer to the Industry Mall for current prices Technical specifications
www.siemens.com/industrymall The technical specifications are for general information purposes only.
Always heed the operating instructions and notices on individual products
during assembly, operation and maintenance.
All illustrations are not binding.
© Siemens 2021
© Siemens 2021
SENTRON · SIVACON · ALPHA

Low-Voltage Power Distribution and


Electrical Installation Technology
I
Introduction   I/2

1
Protecting Air Circuit Breakers   1/1

2
Molded Case Circuit Breakers   2/1

3
Miniature Circuit Breakers   3/1

4
Residual Current Protective Devices/Arc Fault Detection Devices (AFDDs)   4/1

5
Switching Devices   5/1

6
Overvoltage Protection Devices   6/1

7
Fuse Systems   7/1

8
Protecting, Switching and Isolating Switch Disconnectors   8/1

9
Switching and Isolating Transfer Switching Equipment and Load Transfer Switches   9/1

10
Measuring and Monitoring Measuring Devices, Power Monitoring and Digitalization Solutions   10/1

11
Monitoring Devices   11/1

12
Distribution Transformers, Power Supply Units and Socket Outlets   12/1

13
Busbar Systems   13/1

14
Terminal Blocks   14/1

15
Power Distribution Boards, Motor Control Centers and Distribution Boards   15/1

16
Busbar Trunking Systems   16/1

17
System Cubicles, System Lighting and System Air-Conditioning   17/1

A
Appendix   A/1
© Siemens 2021
Miniature Circuit Breakers

Protecting electrical installations


from damage
The number of electrical loads is constantly
increasing, which places an ever greater load on
the electrical installation.

In the event of an overload or short-circuit,


miniature circuit breakers safely cut off the
connected circuit and reliably protect electrical
installations and equipment from damage.
Miniature circuit breakers with communication
and measuring function create transparency right
down to the final circuit and increase system
availability.

Miniature circuit breakers from the SENTRON


portfolio are also simple to mount and install.
The devices have a uniform design and, with
the appropriate accessories, can be expanded by
many additional functions.

For industry, buildings or infrastructure – with


our versatile portfolio, you will find a suitable
miniature circuit breaker for any application.
© Siemens 2021
Miniature Circuit Breakers

Miniature Circuit Breakers

All the information you need   3/2

Devices for all applications   3/4

System overview   3/5

Quick selection guide   3/6

Miniature circuit breakers   3/6

Device protection switches   3/10


3
Basic units   3/12

5SL3 miniature circuit breakers   3/12

5SL6 miniature circuit breakers   3/14

5SL4 miniature circuit breakers   3/16

5SJ6...-.KS miniature circuit breakers   3/18

5SL30 miniature circuit breakers   3/20

5SL60 miniature circuit breakers   3/22

5SY6 miniature circuit breakers   3/24

5SY4 miniature circuit breakers   3/26

5SP4 miniature circuit breakers   3/28

5SY5 miniature circuit breakers   3/30

5SY7 miniature circuit breakers   3/32

5SY8 miniature circuit breakers   3/34

5SJ4..HG.. miniature circuit breakers   3/36

5SL6 COM miniature circuit breakers with


communication and measuring functions new    3/38

5SP3 selective main miniature circuit breakers (SHU)   3/40

5SY17 device protection switches   3/42

5SK9 device protection switches   3/43

Accessories   3/44

Overview of the modular system   3/44

Electrical accessories   3/46

Mechanical accessories   3/56

Standard busbars   3/58

Compact busbars   3/69

Accessories for busbars   3/74

Distribution blocks for standard rail mounting   3/80

SIKclip wiring system   3/83

Siemens LV 10 · 10/2021 3/1


© Siemens 2021
Miniature Circuit Breakers | All the information you need

A multitude of additional information ...

Information + ordering

  All the important things at a glance   Everything you need for your order

For information about miniature circuit breakers, Refer to the Industry Mall for an overview of your
3 please visit our websites products
www.siemens.com/mcb
• Miniature circuit breakers sie.ag/2kTFXI5
www.siemens.com/protection-concept
Direct forwarding to the individual products in the
Industry Mall by clicking on the article number in the cata-
log or by entering this web address incl. article number
  Your product in detail www.siemens.com/product?Article No.

The Siemens Industry Online Support (SIOS) provides


comprehensive information
www.siemens.com/lowvoltage/product-support
• Technical basic information – SENTRON protection
concept (109767456)
• Technology primer – Miniature circuit breakers
(109482304)
The relevant tender specifications can be found at
www.siemens.com/lowvoltage/tenderspecifications
Use our conversion tool for quick and easy conversion to
Siemens products www.siemens.com/conversion-tool

  Siemens YouTube channel

• Miniature circuit breakers (general)


bit.ly/2kJP2Dq

  The fast track to the experts

Contact persons in your region


We offer a comprehensive portfolio of services. Competent expert advice on technical questions with a wide
You can find your local contacts at range of demand-optimized services for all our products and
www.siemens.com/lowvoltage/components/contact systems.
You can find further information on services at Assistance with technical queries is provided at
www.siemens.com/service-catalog www.siemens.com/support-request

3/2 Siemens LV 10 · 10/2021


© Siemens 2021
All the information you need | Miniature Circuit Breakers

... can be found in our online services

Commissioning + operation

  Your product in detail  Manuals

The Siemens Industry Online Support (SIOS) provides Manuals are available for downloading in Siemens
detailed technical information Industry Online Support (SIOS) at
www.siemens.com/lowvoltage/product-support www.siemens.com/lowvoltage/manuals
• Operating instructions • Configuration manual – Miniature circuit breakers
• Characteristic curves (45302792)
• Certificates • Installation manual – Circuit protection devices with
Comprehensive mobile support via the Siemens Industry communication and measuring function (109791805)
Online Support app available for download from the • System manual – Circuit protection devices with
App Store and Play Store communication and measuring function (109791806)
You will find further information under:
www.siemens.com/support-app

Provision of 3D data (step and u3d data formats)


  Classroom or online training
• Siemens Industry Mall
www.siemens.com/lowvoltage/mall Our training courses can be found at
• Image database www.siemens.com/sitrain-lowvoltage
www.siemens.com/lowvoltage/picturedb • SENTRON circuit protection devices with measuring and
communication function (WT-LVBCOM)
Engineering data for CAD or CAE systems are available in
• Basic principles of electrical engineering (WT-LVBGET)
the CAx Download Manager at
• Protection concept (WT-LVBPC)
www.siemens.com/cax

  Technical overview – Miniature circuit breakers

The fast way to get you to our online services


This page provides you with comprehensive information and links on miniature circuit breakers
www.siemens.com/lowvoltage/product-support (109769082)

Siemens LV 10 · 10/2021 3/3


© Siemens 2021
Miniature Circuit Breakers | Devices for all applications

Devices for all applications

Miniature circuit breakers Miniature circuit breakers Device protection switches


for basic applications for advanced ­applications for advanced ­applications

              

Ideal for standard applications Ideal for industrial applications Ideal for devices in industry
The 5SL miniature circuit breakers are For circuits with motors or large lamps, Device protection switches from
the new standard with B and C tripping semiconductors or strong pulse­ Siemens offer optimum protection for
characteristics for applications up to generating equipment such as transfor- all applications in AC and DC control
63 A. They can be used to disconnect or mers and solenoid valves – the 5SY and circuits in industrial applications and
isolate equipment. 5SP devices are optimized for industrial plant engineering.
applications and are proven in use.
The 5SL devices are mainly installed in Thermomagnetic 5SY17 device
meter panels and small distribution The 5SY devices offer you top quality protection switches are used to protect
boards to protect circuits for lamps, and functionality for installation in solenoid valves, servo motors, signal
cookers and even machines, for complex buildings and industry. With a lamps or even PLC inputs. Everywhere
example, in residential or commercial rated breaking capacity of up to 25 kA, where loads have to be precisely
buildings. they are able to handle the most protected from overloads and short-
challenging requirements at a rated circuits.
current of 0.3 to 80 A.
Electronic 5SK9 device protection
Special features switches are optimally suited to
• Dual-chamber terminals protecting, for example, relays,
• Simple to detach without tools using programmable controllers, motors,
sliding catches sensors, actuators and valves. A current
• Separate switching position indication analysis in conjunction with fast tripping
• A wide range of accessories in the event of a fault avoid the danger
• 5SL60 available as communication- of overloading the switched-mode
capable miniature circuit breaker power supply.

5SL6 COM miniature circuit breakers and 5ST3 COM auxiliary switches/fault signal
contacts with communication and measuring functions new
The new communication-capable protective devices and auxiliary components record measured values and status information and
transmit this data wirelessly to higher-level systems.
• Recording of energy and active power, current, voltage, line
frequency and temperature
• Integrated status acquisition, operating hours counter and trip
counter
• Higher system availability through early response to warning
messages
• Convenient integration into new and existing systems thanks to
compact widths of 1 MW
• Fast parameterization and commissioning with the SENTRON
5SL6 COM 5ST3 COM 7KN POC1000 powerconfig mobile app or the SENTRON powerconfig software
see page 3/38 see page 3/50 see page 10/17 • Wireless transmission of measurement data from up to
24 communication-capable devices to the 7KN Powercenter 1000
data transceiver, see page 10/16

3/4 Siemens LV 10 · 10/2021


© Siemens 2021
System overview | Miniature Circuit Breakers

System overview
Basic units and accessories

Miniature circuit breakers for basic applications

5SL3 5SL6 5SL4 5SJ6...-.KS 5SL30 5SL60 5SP3


3
Miniature circuit breakers for advanced applications

5SY6 5SY4 5SP4 5SY5 5SY7 5SY8 5SJ4..HG.. 5SL6 COM new

Device protection switches for advanced applications

5SY17 5SK9

Electrical accessories

Auxiliary switches Fault signal Auxiliary switches and fault signal Shunt trips Undervoltage Remote controlled 5SM6 arc fault
(AS) contacts (FC) contacts (AS+FC)/(AS+FC) COM new (ST) releases (UR) mechanisms (RC mech.) detection units

Mechanical accessories


Rotary operating Spacers Terminal covers Wall enclosures Molded-plastic Holders for front Intermediate
mechanisms enclosures panel installation frames

Busbars and accessories

Compact busbars Standard busbars Terminals Touch protection End caps Series connectors Distribution
blocks
Note:
You will find a detailed range of accessories with the basic units and in the Accessories section.

Siemens LV 10 · 10/2021 3/5


© Siemens 2021
Miniature Circuit Breakers | Quick selection guide

Miniature circuit breakers


For basic applications for buildings and infrastructure

5SL3 5SL6
Standards

3 Standards
Basic data
IEC/EN 60898-1 IEC/EN 60898-1

Breaking capacity Icn for AC (230/400 V) kA 4.5 6


Rated current A 0.3 … 63 0.3 … 63
Number of poles 1P | 2P | 3P | 4P | 1P+N | 3P+N 1P | 2P | 3P | 4P | 1P+N | 3P+N
Tripping characteristic B|C B|C
Approvals
General product approvals VDE, CEBEC, TSE VDE, CEBEC, TSE
Marine classifications – –
Operational voltage
Max. AC V 250/440 250/440
Max. DC per pole Acc. to EN 60898-2, EN 60947-2 V 72 72
Max. AC Acc. to UL 1077, CSA C22.2 No.235 V – –
Rated voltage AC Acc. to UL 489 V – –
Rated impulse withstand voltage Uimp kV 4 4
Rated frequency fn Hz 50/60 50/60
Connection
Dual-chamber terminal – –
Conductor cross-section Solid/stranded mm2 0.75 … 35 0.75 … 35
1 wire Finely stranded with end sleeve mm2 0.75 ... 25 0.75 ... 25
Finely stranded without end sleeve mm2 1 … 35 1 … 35
Conductor cross-section Solid/stranded mm2 0.75 … 10 0.75 … 10
2 wires (same cross-section and same Finely stranded with end sleeve mm2 0.75 … 4 0.75 … 4
conductor type)
Finely stranded without end sleeve mm2 1…4 1…4
Conductor cross-section Solid/stranded mm2 10 … 25 10 … 25
1-wire + busbar Finely stranded with non-insulated end sleeve mm2 6 … 25 6 … 25
(pin thickness 1.5 mm)
Finely stranded with insulated end sleeve mm2 6 … 16 6 … 16
Ambient conditions
Ambient temperature 5) °C –25 … +45 1) –25 … +45 1)
Storage temperature °C –40 … +75 3) –40 … +75 3)
Shock acc. to IEC 60068-2-27 150 m/s at 11 ms half-sine
2
– –
Resistance to vibrations acc. to IEC 60068-2-6: 5 ... 25 Hz (±1mm) and – –
at 25 ... 150 Hz (50 m/s2)
Resistant to shock and vibrations – –
acc. to EN 61373 and EN 50155 "1B" (railway engineering)
Fire behavior of materials acc. to EN 45545-2 – –
(fire protection on railway vehicles)
Pollution degree for overvoltage category 2/III 2/III
More information
See page 3/12 See page 3/14
1)
Periodically +55 °C, max. 95% humidity The device properties specified, for example, in the product standards, such as service
5)

2)
Max. 95% humidity life, breaking capacity and surface temperature, cannot be guaranteed at the specified
3)
95% humidity up to 55 °C ambient temperatures that lie outside the specified product standards.
55% humidity up to 70 °C
30% humidity up to 75 °C
4)
Max. 85% rel. humidity, > 45°C max. 0.056kg/m³ abs. humidity

System overview, page 3/5


3/6 Siemens LV 10 · 10/2021
© Siemens 2021
Quick selection guide | Miniature Circuit Breakers

5SL4 5SJ6...-.KS 5SL30 5SL60 5SP3


IEC/EN 60898-1 IEC/EN 60898-1 IEC/EN 60898-1 IEC/EN 60898-1 DIN VDE 0641-21
3
10 6 4.5 6 25
0.3 … 63 10 … 20 2 … 40 2 … 40 16 … 63
1P | 2P | 3P | 4P | 1P+N | 3P+N 1P | 2P | 3P | 1P+N 1P+N 1P+N 1P | 2P | 3P | 4P
B|C|D B|C C B|C E

VDE, CEBEC, IMQ VDE VDE, IMQ, NF, CCC VDE, IMQ, NF, CCC VDE
– – – DNV-GL –

250/440 250/440 250 250 –


72 60 72 72 –
– – – – –
– – – – –
4 4 4 4 4
50/60 50/60 50/60 50/60 50/60

– Plug-in terminal on outgoing side – – –


0.75 … 35 1.5 … 4 (top) | 0.75 … 25 (bottom) 0.75 … 16 0.75 … 16 2.5 … 50 (bottom)
0.75 ... 25 1.5 … 2.5 (top) | 0.75 … 25 (bottom) 0.75 … 10 0.75 … 10 2.5 … 50 (bottom)
1 … 35 1.5 … 4 0.75 … 16 0.75 … 16 2.5 … 16 (top)
0.75 … 10 – 0.75 … 4 0.75 … 4 –
0.75 … 4 – 0.75 … 1.5 0.75 … 1.5 –
1…4 – 0.75 … 4 0.75 … 4 –
10 … 25 – – – –
6 … 25 – 6 … 10 6 … 10 –
6 … 16 – 6 … 10 6 … 10 –

–25 … +55 2) –25 … +45 1) –25 … +60 –25 … +60 4) –25 … +55
–40 … +75 3) –40 … +75 3) –40 … +75 –40 … +75 –40 … +70
– – – – –
– – – – –

– – – – –

– – – – –

2/III 2/III 2/III 2/III 3/IV

See page 3/16 See page 3/18 See page 3/20 See page 3/22 See page 3/40

System overview, page 3/5


Siemens LV 10 · 10/2021 3/7
© Siemens 2021
Miniature Circuit Breakers | Quick selection guide

Miniature circuit breakers


For advanced applications for buildings and infrastructure and
for industry and machine manufacturing

5SL6 COM 5SY6 5SY4


Standards
Standards IEC/EN 60898-1 IEC/EN 60898-1 IEC/EN 60898-1
IEC/EN 60947-2 IEC/EN 60947-2
3 UL 1077 UL 1077
Basic data
Breaking capacity Icn For AC (230/400 V) acc. to IEC/EN 60898-1 AC kA 6 6 10
Acc. to UL1077 and CSA C22.2 No.235 – Suplementary Suplementary
protector, OC, protector, OC,
FW 0, OL 0, TC 3 at FW 0, OL 0, TC 3 at
50 °C 50 °C
SC – U2: see Certificate U2: see Certificate
of Compliance of Compliance
Rated breaking capacity Icu In 0.3 … 2 A kA – 30 | 30 35 | 35
acc. to IEC/EN 60947-2 at Ue 230 V | at Ue 400 V In 3 … 6 A kA – 30 | 30 35 | 35
(1P, 1P+N) | (2P, 3P, 4P, 3P+N) In 8 … 10 A kA – 15 | 15 20 | 20
In 13 … 32 A kA – 15 | 15 20 | 20
In 35 … 40 A kA – 10 | 10 15 | 15
In 50 … 63 A kA – 10 | 10 15 | 15
In 80 … 125 A kA – –|– 10 | 10
Rated current A 2 … 32 0.3 … 63 0.3 … 80
Number of poles 1P+N 1P | 2P | 3P | 4P | 1P | 2P | 3P | 4P |
1P+N | 3P+N 1P+N | 3P+N
Tripping characteristic B|C B|C A|B|C|D
Approvals
General product approvals VDE, RED VDE, IMQ, CCC, VDE, IMQ, CCC,

Marine classifications – DNV-GL, LR, BV, DNV-GL, LR, BV,


RINA, ABS RINA, ABS
Operational voltage
Max. AC Acc. to EN 60898-1/-2, EN 60947-2 V 250 250/440 250/440
Acc. to UL 1077, CSA C22.2 No.235 V – 277/480 277/480
Max. DC per pole Acc. to EN 60898-1/-2, EN 60947-2 V 72 72 1) 72 1)
Rated voltage AC Acc. to UL 489 V – – –
Rated impulse withstand voltage Uimp kV 4 4 4
Rated frequency fn Hz 50/60 50/60 50/60
Connection
Dual-chamber terminal – ■ ■
Conductor cross-section Solid/stranded mm2 0.75 … 16 0.75 … 35 0.75 … 35
1 wire Finely stranded, with end sleeve mm2 0.75 … 10 0.75 … 25 0.75 … 25
Conductors (Cu 60/75 °C In ≤40 A; 60 °C In >40 A) – AWG 18 … 4 AWG 18 … 4
Terminal tightening torque Nm 1.5 … 2.5 max. 2.5 … 3.5 max. 2.5 … 3.5 max.
lb-in 13 … 22 22 … 26 22 … 26
Ambient conditions
Ambient temperature 7) °C –25 … +60 5) –25 … +55 4) –40 … +70 3)
Storage temperature °C –40 … +75 –40 … +75 3) –40 … +75 3)
Shock acc. to IEC 60068-2-27 150 m/s2 at 11 ms half-sine – ■ ■
Resistance to vibrations acc. to IEC 60068-2-6: 5 ... 25 Hz (±1mm) and – ■ ■
at 25 ... 150 Hz (50 m/s2)
Resistant to shock and vibrations acc. to EN 61373 and EN 50155 ″1B″ (railway engineering) – – ■
Fire behavior of materials acc. to EN 45545-2 (fire protection on railway vehicles) – ■
Pollution degree for overvoltage category 2/ III 3/III 3/III
Additional functions
Communication and measuring function 8) ■ – –
More information
See page 3/38 See page 3/24 See page 3/26
1)
Exempt: C/D 0.3 A … 0.5 A 4)
Max. 95% humidity
2)
5SY54.. 4-pole, degree of pollution 2 for overvoltage category II 5)
Max. 85% rel. humidity, > 45°C max. 0.056kg/m³ abs. humidity
3)
95% humidity up to 55 °C 6)
When used with a busbar at the front or 2 conductors, the terminal area at the rear is
55% humidity up to 70 °C restricted, see notes on the Internet
30% humidity up to 75 °C

System overview, page 3/5


3/8 Siemens LV 10 · 10/2021
© Siemens 2021
Quick selection guide | Miniature Circuit Breakers

5SP4 5SY5 5SY7 5SY8 5SJ4..HG..


IEC/EN 60898-1 IEC/EN 60898-2 IEC/EN 60898-1 IEC/EN 60947-2 IEC/EN 60947-2
UL 1077 UL 1077 IEC/EN 60947-2 UL 1077 UL 489
UL 1077 3
10 10 15 25 –
Suplementary protector, OC, Suplementary protector, OC, Suplementary protector, OC, Suplementary protector, OC, –
FW 0, OL 0, TC 3 at 50°C FW 0, OL 0, TC 3 at 50°C FW 0, OL 0, TC 3 at 50°C FW 0, OL 0, TC 3 at 50°C

U2: see Certificate of U2: see Certificate of U2: see Certificate of U2: see Certificate of –
Compliance Compliance Compliance Compliance
–|– –|– 50 | 50 70 | 70 10
–|– –|– 40 | 40 50 | 50 10
–|– –|– 30 | 30 40 | 40 10
–|– –|– 25 | 25 30 | 30 10
–|– –|– 20 | 20 25 | 25 10
–|– –|– 15 | 15 20 | 20 10
10 | 10 –|– –|– –|– –
80 … 125 0.3 … 63 0.3 … 63 0.3 … 63 0.3 … 63
1P | 2P | 3P | 4P 1P | 2P | 4P 1P | 2P | 3P | 4P | 1P+N | 3P+N 1P | 2P | 3P | 4P | 1P+N | 3P+N 1P | 2P | 3P

B|C|D B|C B|C|D C|D B|C|D

VDE, CCC, VDE, CCC, VDE, IMQ, CCC, VDE, CCC,

LR ABS DNV-GL, LR, BV, RINA, ABS ABS –

250/440 250/440 250/440 250/440 250/440


277/480 – 277/480 277/480 –
72 250 72 1) 72 1) 60
– – – – 277/480
4 4 4 4 4
50/60 50/60 50/60 50/60 50/60

– ■ ■ ■ ■
10 … 50 0.75 … 35 0.75 … 35 0.75 … 35 0.75 … 25 (16) 6)
10 … 35 0.75 … 25 0.75 … 25 0.75 … 25 0.75 … 25 (10)
AWG 3 … 1 AWG 18 … 4 AWG 18 … 4 AWG 18 … 4 AWG 18 … 4 (5)
2.5 … 3.5 max. 2.5 … 3.5 max. 2.5 … 3.5 max. 2.5 … 3.5 max. 2.5 … 3.5 max.
22 … 31 22 … 26 22 … 26 22 … 26 22 … 26

–25 … +55 4) –40 … +70 3) –40 … +70 3) –25 … +55 4) –25 … +55 4)
–40 … +75 3) –40 … +75 3) –40 … +75 3) –40 … +75 3) –40 … +75 3)
– ■ ■ – ■
■ ■ ■ ■ ■

– ■ ■ – –
■ ■ ■ – –
3/III 3/III 4) 3/III 3/III 3/III

– – – – –

See page 3/28 See page 3/30 See page 3/32 See page 3/34 See page 3/36
The device properties specified, for example, in the product standards, such as service
7) 8)
Please note the country-specific radio licenses of the products in SIOS:
life, breaking capacity and surface temperature, cannot be guaranteed at the specified www.siemens.com/lowvoltage/certificates
ambient temperatures that lie outside the specified product standards.

System overview, page 3/5


Siemens LV 10 · 10/2021 3/9
© Siemens 2021
Miniature Circuit Breakers | Quick selection guide

Device protection switches


For advanced applications for industry and machine manufacturing

5SY17
Standards
Standards IEC/EN 60934
UL 1077
3
Basic data
Breaking capacity Icn At rated voltage kA 3
Rated current A 0.5 … 16
Number of poles 1P+AS
DC tripping Magnetic F1 (2.5 … 4 × In) | F2 (4 … 7 × In)
Thermal 1.05 × holding current | 1.35 × tripping current | TC3 1.35 × In
Electronic –
Service life Actuations 6000
Approvals
General product approvals CCC,

Operational voltage
Min. AC Acc. to EN 60934 V 12 2)
Acc. to UL 1077, CSA C22.2 No.235 V 12 2)
Max. AC Acc. to EN 60934 V 250
Acc. to UL 1077, CSA C22.2 No.235 V 277
Min. DC per pole V 12 2)
Max. DC per pole V 72
Rated voltage Acc. to IEC/EN 60934 V 230
Acc. to UL 1077 V 277
Rated impulse withstand voltage Uimp kV 4
Rated frequency fn Hz 50/60
Auxiliary switch
MIn. operational voltage (AC) V 12
Max. operational voltage (AC) V 250
MIn. operational voltage (DC) V 12
Max. operational voltage (DC) V 60
Utilization category AC-12 6A at 230 V AC
Utilization category AC-14 6A at 230 V AC
Utilization category DC-13 1A at 60 V DC
Connection
Dual-chamber terminal –
Conductor cross-section 1 wire Solid/stranded mm2 0.75 … 16
Finely stranded with end sleeve mm2 0.75 … 10
Finely stranded with insulated end sleeve mm2 0.75 … 10
Finely stranded without end sleeve mm2 0.75 … 16
Conductor cross-section AWG –
2-wire (same cross-section) Solid/stranded mm2 0.75 … 4
Finely stranded with end sleeve mm2 0.75 … 2.5
Finely stranded with insulated end sleeve mm2 0.75 … 1.5
Finely stranded without end sleeve mm2 0.75 … 4
Terminal tightening torque Nm 2.0 … 2.5 max.
lb-in 17.7 ... 22.1
Ambient conditions
Ambient temperature °C –25 … +60 3)
Storage temperature °C –40 … +70
Shock acc. to IEC 60068-2-27 150 m/s2 at 11 ms half-sine –
Resistance to vibrations acc. to IEC 60068-2-6: 5 ... 25 Hz (±1mm) and at 25 ... 150 Hz (50 m/s2) –
Resistant to shock and vibrations acc. to EN 61373 and EN 50155 "1B" (railway engineering) –
Fire behavior of materials acc. to EN 45545-2 (fire protection on railway vehicles) –
Pollution degree for overvoltage category Acc. to IEC 2/III
More information
See page 3/42
1)
Max. 95% humidity 2)
At a minimum current of 100 mA

System overview, page 3/5


3/10 Siemens LV 10 · 10/2021
© Siemens 2021
Quick selection guide | Miniature Circuit Breakers

5SK9
EN 61000-6-2, EN 61000-6-3, EN 60068-2-78,
EN 50178, EN 60068-2-6, EN 60068-2-27,
UL 508, UL 2367 3

1…8
1P+AS


Overload 1.2 × In/1s | Short-circuit 2 × In/<10 ms






30


0.5








0.2 … 4
0.2 … 2.5
0.2 … 2.5

AWG 24 ... 12





–25 … +60 1)
–40 … +70




See page 3/43


3)
Max. 85% rel. humidity, > 45°C max. 0.056kg/m³ abs. humidity

System overview, page 3/5


Siemens LV 10 · 10/2021 3/11
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SL3 miniature circuit breakers


4.5 kA

1P 1P+N 2P 3P
230/400 V AC 230 V AC 400 V AC 400 V AC
Mounting width 1 MW 2 MW 2 MW 3 MW
1 1 N 1 3 1 3 5

2 2 N 2 4 2 4 6
3 Rated current In Characteristic Characteristic Characteristic Characteristic
B C B C B C B C
0.3 A – 5SL3114-7 – 5SL3514-7 – 5SL3214-7 – –
0.5 A – 5SL3105-7 – 5SL3505-7 – 5SL3205-7 – –
1A – 5SL3101-7 – 5SL3501-7 – 5SL3201-7 – 5SL3301-7
1.6 A – 5SL3115-7 – 5SL3515-7 – 5SL3215-7 – –
2A – 5SL3102-7 – 5SL3502-7 – 5SL3202-7 – 5SL3302-7
3A – 5SL3103-7 – 5SL3503-7 – 5SL3203-7 – 5SL3303-7
4A – 5SL3104-7 – 5SL3504-7 – 5SL3204-7 – 5SL3304-7
6A 5SL3106-6 5SL3106-7 5SL3506-6 5SL3506-7 5SL3206-6 5SL3206-7 5SL3306-6 5SL3306-7
8A – 5SL3108-7 – 5SL3508-7 – 5SL3208-7 – –
10 A 5SL3110-6 5SL3110-7 5SL3510-6 5SL3510-7 5SL3210-6 5SL3210-7 5SL3310-6 5SL3310-7
13 A 5SL3113-6 5SL3113-7 5SL3513-6 5SL3513-7 5SL3213-6 5SL3213-7 – –
16 A 5SL3116-6 5SL3116-7 5SL3516-6 5SL3516-7 5SL3216-6 5SL3216-7 5SL3316-6 5SL3316-7
20 A 5SL3120-6 5SL3120-7 5SL3520-6 5SL3520-7 5SL3220-6 5SL3220-7 5SL3320-6 5SL3320-7
25 A 5SL3125-6 5SL3125-7 5SL3525-6 5SL3525-7 5SL3225-6 5SL3225-7 5SL3325-6 5SL3325-7
32 A 5SL3132-6 5SL3132-7 5SL3532-6 5SL3532-7 5SL3232-6 5SL3232-7 5SL3332-6 5SL3332-7
40 A 5SL3140-6 5SL3140-7 5SL3540-6 5SL3540-7 5SL3240-6 5SL3240-7 5SL3340-6 5SL3340-7
50 A 5SL3150-6 5SL3150-7 5SL3550-6 5SL3550-7 5SL3250-6 5SL3250-7 5SL3350-6 5SL3350-7
63 A 5SL3163-6 5SL3163-7 5SL3563-6 5SL3563-7 5SL3263-6 5SL3263-7 5SL3363-6 5SL3363-7

Mounting concept
18-22 mm

9 mm

9 mm
9 mm

optionally
or
and

5SL30 AS AS AS
basic unit FC FC + FC
AS+FC AS+FC AS+FC

AS Auxiliary switches See page 3/46


FC Fault signal contacts See page 3/48
AS+FC Auxiliary switches and fault signal contacts See page 3/49

Quick selection guide, page 3/6


3/12 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P+N 4P
400 V AC 400 V AC
4 MW 4 MW
1 3 5 N 1 3 5 7

2 4 6 N 2 4 6 8
Characteristic Characteristic 3
B C B C
– – – –
– – – –
– 5SL3601-7 – 5SL3401-7
– – – –
– 5SL3602-7 – 5SL3402-7
– 5SL3603-7 – 5SL3403-7
– 5SL3604-7 – 5SL3404-7
5SL3606-6 5SL3606-7 – 5SL3406-7
– 5SL3608-7 – –
5SL3610-6 5SL3610-7 – 5SL3410-7
5SL3613-6 5SL3613-7 – 5SL3413-7
5SL3616-6 5SL3616-7 – 5SL3416-7
5SL3620-6 5SL3620-7 – 5SL3420-7
5SL3625-6 5SL3625-7 – 5SL3425-7
5SL3632-6 5SL3632-7 – 5SL3432-7
5SL3640-6 5SL3640-7 – 5SL3440-7
5SL3650-6 5SL3650-7 – 5SL3450-7
5SL3663-6 5SL3663-7 – 5SL3463-7

Accessories
Auxiliary switches (AS) Article No. Fault signal contacts (FC) Article No.
1 NO + 1 NC Standard 5ST3010 1 NO + 1 NC 5ST3020
For low power 5ST3013 2 NO 5ST3021
For low power (with diode) 5ST3013-0XX01 2 NC 5ST3022
2 NO Standard 5ST3011 Auxiliary switches and fault signal contacts (AS+FC) Article No.
For low power 5ST3014 1 CO (AS) + 1 CO (FC) 5ST3062
2 NC Standard 5ST3012 5ST3 COM (AS+FC) new 5ST3062-0MC
For low power 5ST3015
1 CO Standard 5ST3016

Quick selection guide, page 3/6


Siemens LV 10 · 10/2021 3/13
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SL6 miniature circuit breakers


6 kA

1P 1P+N 2P 3P
230/400 V AC 230 V AC 400 V AC 400 V AC
Mounting width 1 MW 2 MW 2 MW 3 MW
1 1 N 1 3 1 3 5

2 2 N 2 4 2 4 6
3 Rated current In Characteristic Characteristic Characteristic Characteristic
B C B C B C B C
0.3 A – 5SL6114-7 – 5SL6514-7 – 5SL6214-7 – 5SL6314-7
0.5 A – 5SL6105-7 – 5SL6505-7 – 5SL6205-7 – 5SL6305-7
1A – 5SL6101-7 – 5SL6501-7 – 5SL6201-7 – 5SL6301-7
1.6 A – 5SL6115-7 – 5SL6515-7 – 5SL6215-7 – 5SL6315-7
2A 5SL6102-6 5SL6102-7 – 5SL6502-7 – 5SL6202-7 – 5SL6302-7
3A – 5SL6103-7 – 5SL6503-7 – 5SL6203-7 – 5SL6303-7
4A 5SL6104-6 5SL6104-7 – 5SL6504-7 – 5SL6204-7 – 5SL6304-7
6A 5SL6106-6 5SL6106-7 5SL6506-6 5SL6506-7 5SL6206-6 5SL6206-7 5SL6306-6 5SL6306-7
8A – 5SL6108-7 – 5SL6508-7 – 5SL6208-7 – 5SL6308-7
10 A 5SL6110-6 5SL6110-7 5SL6510-6 5SL6510-7 5SL6210-6 5SL6210-7 5SL6310-6 5SL6310-7
13 A 5SL6113-6 5SL6113-7 5SL6513-6 5SL6513-7 5SL6213-6 5SL6213-7 5SL6313-6 5SL6313-7
16 A 5SL6116-6 5SL6116-7 5SL6516-6 5SL6516-7 5SL6216-6 5SL6216-7 5SL6316-6 5SL6316-7
20 A 5SL6120-6 5SL6120-7 5SL6520-6 5SL6520-7 5SL6220-6 5SL6220-7 5SL6320-6 5SL6320-7
25 A 5SL6125-6 5SL6125-7 5SL6525-6 5SL6525-7 5SL6225-6 5SL6225-7 5SL6325-6 5SL6325-7
32 A 5SL6132-6 5SL6132-7 5SL6532-6 5SL6532-7 5SL6232-6 5SL6232-7 5SL6332-6 5SL6332-7
40 A 5SL6140-6 5SL6140-7 5SL6540-6 5SL6540-7 5SL6240-6 5SL6240-7 5SL6340-6 5SL6340-7
50 A 5SL6150-6 5SL6150-7 5SL6550-6 5SL6550-7 5SL6250-6 5SL6250-7 5SL6350-6 5SL6350-7
63 A 5SL6163-6 5SL6163-7 5SL6563-6 5SL6563-7 5SL6263-6 5SL6263-7 5SL6363-6 5SL6363-7

Mounting concept
18 – 72 mm

27 – 36 mm

9 mm

9 mm
9 mm

optionally optionally
or
and and

5SL3 RC mech. AS AS AS
basic unit and FC FC + FC
AS+FC AS+FC AS+FC

Adapter

AS Auxiliary switches See page 3/46


FC Fault signal contacts See page 3/48
AS+FC Auxiliary switches and fault signal contacts See page 3/49
RC mech. Remote controlled mechanisms See page 3/54

Quick selection guide, page 3/6


3/14 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P+N 4P
400 V AC 400 V AC
4 MW 4 MW
1 3 5 N 1 3 5 7

2 4 6 N 2 4 6 8
Characteristic Characteristic 3
B C B C
– 5SL6614-7 – 5SL6414-7
– 5SL6605-7 – 5SL6405-7
– 5SL6601-7 – 5SL6401-7
– 5SL6615-7 – 5SL6415-7
– 5SL6602-7 – 5SL6402-7
– 5SL6603-7 – 5SL6403-7
– 5SL6604-7 – 5SL6404-7
5SL6606-6 5SL6606-7 5SL6406-6 5SL6406-7
– 5SL6608-7 – 5SL6408-7
5SL6610-6 5SL6610-7 5SL6410-6 5SL6410-7
5SL6613-6 5SL6613-7 5SL6413-6 5SL6413-7
5SL6616-6 5SL6616-7 5SL6416-6 5SL6416-7
5SL6620-6 5SL6620-7 5SL6420-6 5SL6420-7
5SL6625-6 5SL6625-7 5SL6425-6 5SL6425-7
5SL6632-6 5SL6632-7 5SL6432-6 5SL6432-7
5SL6640-6 5SL6640-7 5SL6440-6 5SL6440-7
5SL6650-6 5SL6650-7 5SL6450-6 5SL6450-7
5SL6663-6 5SL6663-7 5SL6463-6 5SL6463-7

Accessories
Auxiliary switches (AS) Article No. Auxiliary switches and fault signal contacts (AS+FC) Article No.
1 NO + 1 NC Standard 5ST3010 1 CO (AS) + 1 CO (FC) 5ST3062
For low power 5ST3013 5ST3 COM (AS+FC) new 5ST3062-0MC
For low power (with diode) 5ST3013-0XX01 Remote controlled mechanisms (RC mech.) Article No.
2 NO Standard 5ST3011 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
For low power 5ST3014 177 … 270 V AC 5ST3054
2 NC Standard 5ST3012 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
For low power 5ST3015 177 … 270 V AC 5ST3056
1 CO Standard 5ST3016 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3058
1 NO + 1 NC 5ST3020 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
2 NO 5ST3021 function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
2 NC 5ST3022 Adapters for remote controlled mechanisms (RC mech.) Article No.
1–2 MW 5ST3820-6
3–4 MW 5ST3820-7

Quick selection guide, page 3/6


Siemens LV 10 · 10/2021 3/15
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SL4 miniature circuit breakers


10 kA

1P 1P+N 2P
230/400 V AC 230 V AC 400 V AC
Mounting width 1 MW 2 MW 2 MW
1 1 N 1 3

2 2 N 2 4
3 Rated Characteristic Characteristic Characteristic
current In B C D B C D B C D
0.3 A – 5SL4114-7 5SL4114-8 – 5SL4514-7 5SL4514-8 – 5SL4214-7 5SL4214-8
0.5 A – 5SL4105-7 5SL4105-8 – 5SL4505-7 5SL4505-8 – 5SL4205-7 5SL4205-8
1A 5SL4101-6 5SL4101-7 5SL4101-8 5SL4501-6 5SL4501-7 5SL4501-8 5SL4201-6 5SL4201-7 5SL4201-8
1.6 A – 5SL4115-7 5SL4115-8 – 5SL4515-7 5SL4515-8 – 5SL4215-7 5SL4215-8
2A 5SL4102-6 5SL4102-7 5SL4102-8 5SL4502-6 5SL4502-7 5SL4502-8 5SL4202-6 5SL4202-7 5SL4202-8
3A 5SL4103-6 5SL4103-7 5SL4103-8 5SL4503-6 5SL4503-7 5SL4503-8 5SL4203-6 5SL4203-7 5SL4203-8
4A 5SL4104-6 5SL4104-7 5SL4104-8 5SL4504-6 5SL4504-7 5SL4504-8 5SL4204-6 5SL4204-7 5SL4204-8
6A 5SL4106-6 5SL4106-7 5SL4106-8 5SL4506-6 5SL4506-7 5SL4506-8 5SL4206-6 5SL4206-7 5SL4206-8
8A 5SL4108-6 5SL4108-7 5SL4108-8 5SL4508-6 5SL4508-7 5SL4508-8 5SL4208-6 5SL4208-7 5SL4208-8
10 A 5SL4110-6 5SL4110-7 5SL4110-8 5SL4510-6 5SL4510-7 5SL4510-8 5SL4210-6 5SL4210-7 5SL4210-8
13 A 5SL4113-6 5SL4113-7 5SL4113-8 5SL4513-6 5SL4513-7 5SL4513-8 5SL4213-6 5SL4213-7 5SL4213-8
16 A 5SL4116-6 5SL4116-7 5SL4116-8 5SL4516-6 5SL4516-7 5SL4516-8 5SL4216-6 5SL4216-7 5SL4216-8
20 A 5SL4120-6 5SL4120-7 5SL4120-8 5SL4520-6 5SL4520-7 5SL4520-8 5SL4220-6 5SL4220-7 5SL4220-8
25 A 5SL4125-6 5SL4125-7 5SL4125-8 5SL4525-6 5SL4525-7 5SL4525-8 5SL4225-6 5SL4225-7 5SL4225-8
32 A 5SL4132-6 5SL4132-7 5SL4132-8 5SL4532-6 5SL4532-7 5SL4532-8 5SL4232-6 5SL4232-7 5SL4232-8
40 A 5SL4140-6 5SL4140-7 5SL4140-8 5SL4540-6 5SL4540-7 5SL4540-8 5SL4240-6 5SL4240-7 5SL4240-8
50 A 5SL4150-6 5SL4150-7 5SL4150-8 5SL4550-6 5SL4550-7 5SL4550-8 5SL4250-6 5SL4250-7 5SL4250-8
63 A 5SL4163-6 5SL4163-7 5SL4163-8 5SL4563-6 5SL4563-7 5SL4563-8 5SL4263-6 5SL4263-7 5SL4263-8

Mounting concept
18 mm

36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm
optionally optionally
or or or or
and and

5SM6 5SL4 AS AS AS ST ST AS ST AS AS
AFDD basic unit FC FC + FC UR UR + FC UR + FC + FC
(1P+N) up to AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC
max. 40 A
18 – 72 mm

27 – 36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

5SL4 RC mech. AS AS AS ST ST AS ST AS AS
basic unit and FC FC + FC UR UR + FC UR + FC + FC
AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC

Adapter

AFDD Arc fault detection units See page 3/55 AS+FC Auxiliary switches and UR Undervoltage releases See page 3/53
AS Auxiliary switches See page 3/46 fault signal contacts See page 3/49 RC mech. Remote controlled mechanisms See page 3/54
FC Fault signal contacts See page 3/48 ST Shunt trips See page 3/52

Quick selection guide, page 3/6


3/16 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P 3P+N 4P
400 V AC 400 V AC 400 V AC
3 MW 4 MW 4 MW
1 3 5 1 3 5 N 1 3 5 7

2 4 6 2 4 6 N 2 4 6 8
Characteristic Characteristic Characteristic 3
B C D B C D B C D
– 5SL4314-7 5SL4314-8 – 5SL4614-7 5SL4614-8 – 5SL4414-7 5SL4414-8
– 5SL4305-7 5SL4305-8 – 5SL4605-7 5SL4605-8 – 5SL4405-7 5SL4405-8
5SL4301-6 5SL4301-7 5SL4301-8 5SL4601-6 5SL4601-7 5SL4601-8 5SL4401-6 5SL4401-7 5SL4401-8
– 5SL4315-7 5SL4315-8 – 5SL4615-7 5SL4615-8 – 5SL4415-7 5SL4415-8
5SL4302-6 5SL4302-7 5SL4302-8 5SL4602-6 5SL4602-7 5SL4602-8 5SL4402-6 5SL4402-7 5SL4402-8
5SL4303-6 5SL4303-7 5SL4303-8 5SL4603-6 5SL4603-7 5SL4603-8 5SL4403-6 5SL4403-7 5SL4403-8
5SL4304-6 5SL4304-7 5SL4304-8 5SL4604-6 5SL4604-7 5SL4604-8 5SL4404-6 5SL4404-7 5SL4404-8
5SL4306-6 5SL4306-7 5SL4306-8 5SL4606-6 5SL4606-7 5SL4606-8 5SL4406-6 5SL4406-7 5SL4406-8
5SL4308-6 5SL4308-7 5SL4308-8 5SL4608-6 5SL4608-7 5SL4608-8 5SL4408-6 5SL4408-7 5SL4408-8
5SL4310-6 5SL4310-7 5SL4310-8 5SL4610-6 5SL4610-7 5SL4610-8 5SL4410-6 5SL4410-7 5SL4410-8
5SL4313-6 5SL4313-7 5SL4313-8 5SL4613-6 5SL4613-7 5SL4613-8 5SL4413-6 5SL4413-7 5SL4413-8
5SL4316-6 5SL4316-7 5SL4316-8 5SL4616-6 5SL4616-7 5SL4616-8 5SL4416-6 5SL4416-7 5SL4416-8
5SL4320-6 5SL4320-7 5SL4320-8 5SL4620-6 5SL4620-7 5SL4620-8 5SL4420-6 5SL4420-7 5SL4420-8
5SL4325-6 5SL4325-7 5SL4325-8 5SL4625-6 5SL4625-7 5SL4625-8 5SL4425-6 5SL4425-7 5SL4425-8
5SL4332-6 5SL4332-7 5SL4332-8 5SL4632-6 5SL4632-7 5SL4632-8 5SL4432-6 5SL4432-7 5SL4432-8
5SL4340-6 5SL4340-7 5SL4340-8 5SL4640-6 5SL4640-7 5SL4640-8 5SL4440-6 5SL4440-7 5SL4440-8
5SL4350-6 5SL4350-7 5SL4350-8 5SL4650-6 5SL4650-7 5SL4650-8 5SL4450-6 5SL4450-7 5SL4450-8
5SL4363-6 5SL4363-7 5SL4363-8 5SL4663-6 5SL4663-7 5SL4663-8 5SL4463-6 5SL4463-7 5SL4463-8

Accessories
Auxiliary switches (AS) Article No. Undervoltage releases (UR) Article No.
1 NO + 1 NC Standard 5ST3010 With integrated 230 V AC 5ST3040
For low power 5ST3013 auxiliary switch 110 V DC 5ST3041
For low power (with diode) 5ST3013-0XX01 24 V DC 5ST3042
2 NO Standard 5ST3011 Without integrated 230 V AC 5ST3043
For low power 5ST3014 auxiliary switch 110 V DC 5ST3044
2 NC Standard 5ST3012 24 V DC 5ST3045
For low power 5ST3015 Remote controlled mechanisms (RC mech.) Article No.
1 CO Standard 5ST3016 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3054
1 NO + 1 NC 5ST3020 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
2 NO 5ST3021 177 … 270 V AC 5ST3056
2 NC 5ST3022 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Auxiliary switches and fault signal contacts (AS+FC) Article No. 177 … 270 V AC 5ST3058
1 CO (AS) + 1 CO (FC) 5ST3062 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
5ST3 COM (AS+FC) new 5ST3062-0MC function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
Shunt trips (ST) Article No. Adapters for remote controlled mechanisms (RC mech.) Article No.
110 … 415 V AC, 110 … 220 V DC 5ST3030 1–2 MW 5ST3820-6
24 ... 48 V AC/DC 5ST3031 3–4 MW 5ST3820-7
12 V DC 5ST3031-0XX01 Arc fault detection units (AFDD) Article No.
For basic units 1P+N (2 MW), In up to 16 A 5SM6021-2
not in combination with RC mech. In up to 40 A 5SM6024-2

Quick selection guide, page 3/6


Siemens LV 10 · 10/2021 3/17
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SJ6...-.KS miniature circuit breakers


6 kA – plug-in terminal on outgoing side

1P 1P+N 2P 3P
230/400 V AC 230/400 V AC 230/400 V AC 230/400 V AC
Mounting width 1 MW 2 MW 2 MW 3 MW
1 1 N 1 3 1 3 5

2 2 N 2 4 2 4 6
3 Rated current In Characteristic Characteristic Characteristic Characteristic
B C B C B C B C
10 A 5SJ6110-6KS 5SJ6110-7KS 5SJ6510-6KS 5SJ6510-7KS 5SJ6210-6KS 5SJ6210-7KS 5SJ6310-6KS 5SJ6310-7KS
13 A 5SJ6113-6KS 5SJ6113-7KS 5SJ6513-6KS 5SJ6513-7KS 5SJ6213-6KS 5SJ6213-7KS 5SJ6313-6KS 5SJ6313-7KS
16 A 5SJ6116-6KS 5SJ6116-7KS 5SJ6516-6KS 5SJ6516-7KS 5SJ6216-6KS 5SJ6216-7KS 5SJ6316-6KS 5SJ6316-7KS
20 A 5SJ6120-6KS 5SJ6120-7KS 5SJ6520-6KS 5SJ6520-7KS 5SJ6220-6KS 5SJ6220-7KS 5SJ6320-6KS 5SJ6320-7KS

Quick selection guide, page 3/6


3/18 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

Quick selection guide, page 3/6


Siemens LV 10 · 10/2021 3/19
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SL30 miniature circuit breakers


1P+N 4.5 kA compact miniature circuit breakers

1P+N (N pole right) 1P+N (N pole left)


230 V AC 230 V AC
Mounting width 2 MW 2 MW
1 N N 1

2 N N 2
3 Rated current In Characteristic Characteristic
C C
2A 5SL3002-7 5SL3002-7KL
4A 5SL3004-7 5SL3004-7KL
6A 5SL3006-7 5SL3006-7KL
8A 5SL3008-7 5SL3008-7KL
10 A 5SL3010-7 5SL3010-7KL
13 A 5SL3013-7 5SL3013-7KL
16 A 5SL3016-7 5SL3016-7KL
20 A 5SL3020-7 5SL3020-7KL
25 A 5SL3025-7 5SL3025-7KL
32 A 5SL3032-7 5SL3032-7KL
40 A 5SL3040-7 5SL3040-7KL

Mounting concept
18 mm

9 mm

9 mm
9 mm

optionally
or
and

5SL30 AS AS AS
basic unit FC FC + FC
AS+FC AS+FC AS+FC

AS Auxiliary switches See page 3/46


FC Fault signal contacts See page 3/48
AS+FC Auxiliary switches and fault signal contacts See page 3/49

Quick selection guide, page 3/6


3/20 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

Accessories
Auxiliary switches (AS) Article No. Fault signal contacts (FC) Article No.
1 NO + 1 NC Standard 5ST3010 1 NO + 1 NC 5ST3020
For low power 5ST3013 2 NO 5ST3021
For low power (with diode) 5ST3013-0XX01 2 NC 5ST3022
2 NO Standard 5ST3011 Auxiliary switches and fault signal contacts (AS+FC) Article No.
For low power 5ST3014 1 CO (AS) + 1 CO (FC) 5ST3062
2 NC Standard 5ST3012 5ST3 COM (AS+FC) new 5ST3062-0MC
For low power 5ST3015
1 CO Standard 5ST3016

Quick selection guide, page 3/6


Siemens LV 10 · 10/2021 3/21
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SL60 miniature circuit breakers


1P+N 6 kA compact miniature circuit breakers

1P+N (N pole right) 1P+N (N pole left)


230 V AC 230 V AC
Mounting width 1 MW 1 MW
1 N N 1

2 N N 2
3 Rated current In Characteristic Characteristic
B C C
2A – 5SL6002-7 5SL6002-7KL
4A – 5SL6004-7 5SL6004-7KL
6A 5SL6006-6 5SL6006-7 5SL6006-7KL
8A – 5SL6008-7 5SL6008-7KL
10 A 5SL6010-6 5SL6010-7 5SL6010-7KL
13 A 5SL6013-6 5SL6013-7 5SL6013-7KL
16 A 5SL6016-6 5SL6016-7 5SL6016-7KL
20 A 5SL6020-6 5SL6020-7 5SL6020-7KL
25 A 5SL6025-6 5SL6025-7 5SL6025-7KL
32 A 5SL6032-6 5SL6032-7 5SL6032-7KL
40 A 5SL6040-6 5SL6040-7 5SL6040-7KL

Mounting concept
18 mm

18 mm

9 mm

9 mm
9 mm

optionally optionally
or
and and

AFDD 5SL60 AS AS AS
basic unit FC FC + FC
(not for KL types) AS+FC AS+FC AS+FC
27 – 36 mm
18 mm

9 mm

9 mm
9 mm

optionally optionally
or
and and

5SL60 RC mech. AS AS AS
basic unit and FC FC + FC
AS+FC AS+FC AS+FC

Adapter

AFDD Arc fault detection units See page 3/55


AS Auxiliary switches See page 3/46
FC Fault signal contacts See page 3/48
AS+FC Auxiliary switches and fault signal contacts See page 3/49
RC mech. Remote controlled mechanisms See page 3/54

Quick selection guide, page 3/6


3/22 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

Accessories
Auxiliary switches (AS) Article No. Remote controlled mechanisms (RC mech.) Article No.
1 NO + 1 NC Standard 5ST3010 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
For low power 5ST3013 177 … 270 V AC 5ST3054
For low power (with diode) 5ST3013-0XX01 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
2 NO Standard 5ST3011 177 … 270 V AC 5ST3056
For low power 5ST3014 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
2 NC Standard 5ST3012 177 … 270 V AC 5ST3058
For low power 5ST3015 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
1 CO Standard 5ST3016 function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
Fault signal contacts (FC) Article No. Adapters for remote controlled mechanisms (RC mech.) Article No.
1 NO + 1 NC 5ST3020 1 MW 5ST3820-6
2 NO 5ST3021 Arc fault detection units (AFDD) Article No.
2 NC 5ST3022 For basic units 1P + N (1 In up to 16 A 5SM6011-2
Auxiliary switches and fault signal contacts (AS+FC) Article No. MW), In up to 40 A 5SM6014-2
1 CO (AS) + 1 CO (FC) 5ST3062 not for KL types
5ST3 COM (AS+FC) new 5ST3062-0MC

Quick selection guide, page 3/6


Siemens LV 10 · 10/2021 3/23
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SY6 miniature circuit breakers


6 kA

1P 1P+N 2P 3P
230/400 V AC 230 V AC 400 V AC 400 V AC
Mounting width 1 MW 2 MW 2 MW 3 MW
1 1 N 1 3 1 3 5

2 2 N 2 4 2 4 6
3 Rated current In Characteristic Characteristic Characteristic Characteristic
B C B C B C B C
0.3 A – 5SY6114-7 – 5SY6514-7 – 5SY6214-7 – 5SY6314-7
0.5 A – 5SY6105-7 – 5SY6505-7 – 5SY6205-7 – 5SY6305-7
1A – 5SY6101-7 – 5SY6501-7 – 5SY6201-7 – 5SY6301-7
1.6 A – 5SY6115-7 – 5SY6515-7 – 5SY6215-7 – 5SY6315-7
2A 5SY6102-6 5SY6102-7 – 5SY6502-7 – 5SY6202-7 – 5SY6302-7
3A – 5SY6103-7 – 5SY6503-7 – 5SY6203-7 – 5SY6303-7
4A 5SY6104-6 5SY6104-7 – 5SY6504-7 – 5SY6204-7 – 5SY6304-7
5A – 5SY6111-7 – – – 5SY6211-7 – 5SY6311-7
6A 5SY6106-6 5SY6106-7 5SY6506-6 5SY6506-7 5SY6206-6 5SY6206-7 5SY6306-6 5SY6306-7
8A – 5SY6108-7 – 5SY6508-7 – 5SY6208-7 – 5SY6308-7
10 A 5SY6110-6 5SY6110-7 5SY6510-6 5SY6510-7 5SY6210-6 5SY6210-7 5SY6310-6 5SY6310-7
13 A 5SY6113-6 5SY6113-7 5SY6513-6 5SY6513-7 5SY6213-6 5SY6213-7 5SY6313-6 5SY6313-7
15 A – 5SY6118-7 – – – 5SY6218-7 – 5SY6318-7
16 A 5SY6116-6 5SY6116-7 5SY6516-6 5SY6516-7 5SY6216-6 5SY6216-7 5SY6316-6 5SY6316-7
20 A 5SY6120-6 5SY6120-7 5SY6520-6 5SY6520-7 5SY6220-6 5SY6220-7 5SY6320-6 5SY6320-7
25 A 5SY6125-6 5SY6125-7 5SY6525-6 5SY6525-7 5SY6225-6 5SY6225-7 5SY6325-6 5SY6325-7
30 A – 5SY6130-7 – – – 5SY6230-7 – 5SY6330-7
32 A 5SY6132-6 5SY6132-7 5SY6532-6 5SY6532-7 5SY6232-6 5SY6232-7 5SY6332-6 5SY6332-7
40 A 5SY6140-6 5SY6140-7 5SY6540-6 5SY6540-7 5SY6240-6 5SY6240-7 5SY6340-6 5SY6340-7
50 A 5SY6150-6 5SY6150-7 5SY6550-6 5SY6550-7 5SY6250-6 5SY6250-7 5SY6350-6 5SY6350-7
63 A 5SY6163-6 5SY6163-7 5SY6563-6 5SY6563-7 5SY6263-6 5SY6263-7 5SY6363-6 5SY6363-7

Mounting concept
18 mm

36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm
optionally optionally
or or or or
and and

AFDD 5SY6 AS AS AS ST ST AS ST AS AS
basic unit FC FC + FC UR UR + FC UR + FC + FC
(1P+N) AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC
up to
max. 40 A
18 – 72 mm

27 – 36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

5SY6 RC mech. AS AS AS ST ST AS ST AS AS
basic unit and FC FC + FC UR UR + FC UR + FC + FC
AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC

Adapter

AFDD Arc fault detection units See page 3/55 AS+FC Auxiliary switches and UR Undervoltage releases See page 3/53
AS Auxiliary switches See page 3/46 fault signal contacts See page 3/49 RC mech. Remote controlled mechanisms See page 3/54
FC Fault signal contacts See page 3/48 ST Shunt trips See page 3/52

Quick selection guide, page 3/8


3/24 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P+N 4P
400 V AC 400 V AC
4 MW 4 MW
1 3 5 N 1 3 5 7

2 4 6 N 2 4 6 8
Characteristic Characteristic 3
B C B C
– 5SY6614-7 – 5SY6414-7
– 5SY6605-7 – 5SY6405-7
– 5SY6601-7 – 5SY6401-7
– 5SY6615-7 – 5SY6415-7
– 5SY6602-7 – 5SY6402-7
– 5SY6603-7 – 5SY6403-7
– 5SY6604-7 – 5SY6404-7
– – – –
5SY6606-6 5SY6606-7 5SY6406-6 5SY6406-7
– 5SY6608-7 – 5SY6408-7
5SY6610-6 5SY6610-7 5SY6410-6 5SY6410-7
5SY6613-6 5SY6613-7 5SY6413-6 5SY6413-7
– – – –
5SY6616-6 5SY6616-7 5SY6416-6 5SY6416-7
5SY6620-6 5SY6620-7 5SY6420-6 5SY6420-7
5SY6625-6 5SY6625-7 5SY6425-6 5SY6425-7
– – – –
5SY6632-6 5SY6632-7 5SY6432-6 5SY6432-7
5SY6640-6 5SY6640-7 5SY6440-6 5SY6440-7
5SY6650-6 5SY6650-7 5SY6450-6 5SY6450-7
5SY6663-6 5SY6663-7 5SY6463-6 5SY6463-7

Accessories
Auxiliary switches (AS) Article No. Undervoltage releases (UR) Article No.
1 NO + 1 NC Standard 5ST3010 With integrated 230 V AC 5ST3040
For low power 5ST3013 auxiliary switch 110 V DC 5ST3041
For low power (with diode) 5ST3013-0XX01 24 V DC 5ST3042
2 NO Standard 5ST3011 Without integrated 230 V AC 5ST3043
For low power 5ST3014 auxiliary switch 110 V DC 5ST3044
2 NC Standard 5ST3012 24 V DC 5ST3045
For low power 5ST3015 Remote controlled mechanisms (RC mech.) Article No.
1 CO Standard 5ST3016 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3054
1 NO + 1 NC 5ST3020 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
2 NO 5ST3021 177 … 270 V AC 5ST3056
2 NC 5ST3022 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Auxiliary switches and fault signal contacts (AS+FC) Article No. 177 … 270 V AC 5ST3058
1 CO (AS) + 1 CO (FC) 5ST3062 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
5ST3 COM (AS+FC) new 5ST3062-0MC function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
Shunt trips (ST) Article No. Adapters for remote controlled mechanisms (RC mech.) Article No.
110 … 415 V AC, 110 … 220 DC 5ST3030 1–2 MW 5ST3820-1
24 ... 48 V AC/DC 5ST3031 3–4 MW 5ST3820-2
12 V DC 5ST3031-0XX01 Arc fault detection units (AFDD) Article No.
For basic units 1P+N (2 MW), In up to 16 A 5SM6021-2
not in combination with RC mech. In up to 40 A 5SM6024-2

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/25
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SY4 miniature circuit breakers


10 kA

1P 1P+N 2P
230/400 V AC 230 V AC 400 V AC
Mounting 1 MW 2 MW 2 MW
width
1 1 N 1 3

2 2 N 2 4
3 Rated Characteristic Characteristic Characteristic
­current In A B C D A B C D A B C D
0.3 A – – 5SY4114-7 5SY4114-8 – – 5SY4514-7 5SY4514-8 – – 5SY4214-7 5SY4214-8
0.5 A 5SY4105-5 – 5SY4105-7 5SY4105-8 – – 5SY4505-7 5SY4505-8 5SY4205-5 – 5SY4205-7 5SY4205-8
1A 5SY4101-5 5SY4101-6 5SY4101-7 5SY4101-8 5SY4501-5 – 5SY4501-7 5SY4501-8 5SY4201-5 5SY4201-6 5SY4201-7 5SY4201-8
1.6 A 5SY4115-5 5SY4115-6 5SY4115-7 5SY4115-8 5SY4515-5 5SY4515-6 5SY4515-7 5SY4515-8 5SY4215-5 5SY4215-6 5SY4215-7 5SY4215-8
2A 5SY4102-5 5SY4102-6 5SY4102-7 5SY4102-8 5SY4502-5 – 5SY4502-7 5SY4502-8 5SY4202-5 5SY4202-6 5SY4202-7 5SY4202-8
3A 5SY4103-5 5SY4103-6 5SY4103-7 5SY4103-8 5SY4503-5 – 5SY4503-7 5SY4503-8 5SY4203-5 5SY4203-6 5SY4203-7 5SY4203-8
4A 5SY4104-5 5SY4104-6 5SY4104-7 5SY4104-8 5SY4504-5 5SY4504-6 5SY4504-7 5SY4504-8 5SY4204-5 5SY4204-6 5SY4204-7 5SY4204-8
5A – – 5SY4111-7 – – – – – – – 5SY4211-7 –
6A 5SY4106-5 5SY4106-6 5SY4106-7 5SY4106-8 5SY4506-5 5SY4506-6 5SY4506-7 5SY4506-8 5SY4206-5 5SY4206-6 5SY4206-7 5SY4206-8
8A 5SY4108-5 5SY4108-6 5SY4108-7 5SY4108-8 5SY4508-5 – 5SY4508-7 5SY4508-8 5SY4208-5 5SY4208-6 5SY4208-7 5SY4208-8
10 A 5SY4110-5 5SY4110-6 5SY4110-7 5SY4110-8 5SY4510-5 5SY4510-6 5SY4510-7 5SY4510-8 5SY4210-5 5SY4210-6 5SY4210-7 5SY4210-8
13 A 5SY4113-5 5SY4113-6 5SY4113-7 5SY4113-8 5SY4513-5 5SY4513-6 5SY4513-7 5SY4513-8 5SY4213-5 5SY4213-6 5SY4213-7 5SY4213-8
15 A – – 5SY4118-7 – – – – – – – 5SY4218-7 –
16 A 5SY4116-5 5SY4116-6 5SY4116-7 5SY4116-8 5SY4516-5 5SY4516-6 5SY4516-7 5SY4516-8 5SY4216-5 5SY4216-6 5SY4216-7 5SY4216-8
20 A 5SY4120-5 5SY4120-6 5SY4120-7 5SY4120-8 5SY4520-5 5SY4520-6 5SY4520-7 5SY4520-8 5SY4220-5 5SY4220-6 5SY4220-7 5SY4220-8
25 A 5SY4125-5 5SY4125-6 5SY4125-7 5SY4125-8 5SY4525-5 5SY4525-6 5SY4525-7 5SY4525-8 5SY4225-5 5SY4225-6 5SY4225-7 5SY4225-8
30 A – – 5SY4130-7 – – – – – – – 5SY4230-7 –
32 A 5SY4132-5 5SY4132-6 5SY4132-7 5SY4132-8 5SY4532-5 5SY4532-6 5SY4532-7 5SY4532-8 5SY4232-5 5SY4232-6 5SY4232-7 5SY4232-8
35 A – – 5SY4135-7 – – – – – – – 5SY4235-7 –
40 A 5SY4140-5 5SY4140-6 5SY4140-7 5SY4140-8 5SY4540-5 5SY4540-6 5SY4540-7 5SY4540-8 5SY4240-5 5SY4240-6 5SY4240-7 5SY4240-8
45 A – – 5SY4145-7 – – – – – – – 5SY4245-7 –
50 A 5SY4150-5 5SY4150-6 5SY4150-7 5SY4150-8 5SY4550-5 5SY4550-6 5SY4550-7 5SY4550-8 5SY4250-5 5SY4250-6 5SY4250-7 5SY4250-8
60 A – – 5SY4160-7 – – – – – – – 5SY4260-7 –
63 A 5SY4163-5 5SY4163-6 5SY4163-7 5SY4163-8 5SY4563-5 5SY4563-6 5SY4563-7 5SY4563-8 5SY4263-5 5SY4263-6 5SY4263-7 5SY4263-8
80 A – 5SY4180-6 5SY4180-7 – – – 5SY4580-7 – – 5SY4280-6 5SY4280-7 –

Mounting concept
18 mm

36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

AFDD 5SY4 AS AS AS ST ST AS ST AS AS
basic unit (1P+N) FC FC + FC UR UR + FC UR + FC + FC
up to max. 40 A AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC
18 – 72 mm

27 – 36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

5SY4 RC mech. AS AS AS ST ST AS ST AS AS
basic unit and FC FC + FC UR UR + FC UR + FC + FC
AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC

Adapter

Quick selection guide, page 3/8


3/26 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P 3P+N 4P
400 V AC 400 V AC 400 V AC
3 MW 4 MW 4 MW
1 3 5 1 3 5 N 1 3 5 7

2 4 6 2 4 6 N 2 4 6 8
Characteristic Characteristic Characteristic 3
A B C D A B C D A B C D
– – 5SY4314-7 5SY4314-8 – – 5SY4614-7 5SY4614-8 – – 5SY4414-7 5SY4414-8
5SY4305-5 – 5SY4305-7 5SY4305-8 – – 5SY4605-7 5SY4605-8 – – 5SY4405-7 5SY4405-8
5SY4301-5 5SY4301-6 5SY4301-7 5SY4301-8 5SY4601-5 – 5SY4601-7 5SY4601-8 5SY4401-5 – 5SY4401-7 5SY4401-8
5SY4315-5 5SY4315-6 5SY4315-7 5SY4315-8 5SY4615-5 – 5SY4615-7 5SY4615-8 5SY4415-5 – 5SY4415-7 5SY4415-8
5SY4302-5 5SY4302-6 5SY4302-7 5SY4302-8 5SY4602-5 – 5SY4602-7 5SY4602-8 5SY4402-5 – 5SY4402-7 5SY4402-8
5SY4303-5 5SY4303-6 5SY4303-7 5SY4303-8 5SY4603-5 – 5SY4603-7 5SY4603-8 5SY4403-5 – 5SY4403-7 5SY4403-8
5SY4304-5 5SY4304-6 5SY4304-7 5SY4304-8 5SY4604-5 – 5SY4604-7 5SY4604-8 5SY4404-5 – 5SY4404-7 5SY4404-8
– – 5SY4311-7 – – – – – – – – –
5SY4306-5 5SY4306-6 5SY4306-7 5SY4306-8 5SY4606-5 5SY4606-6 5SY4606-7 5SY4606-8 5SY4406-5 5SY4406-6 5SY4406-7 5SY4406-8
5SY4308-5 5SY4308-6 5SY4308-7 5SY4308-8 5SY4608-5 – 5SY4608-7 5SY4608-8 5SY4408-5 – 5SY4408-7 5SY4408-8
5SY4310-5 5SY4310-6 5SY4310-7 5SY4310-8 5SY4610-5 5SY4610-6 5SY4610-7 5SY4610-8 5SY4410-5 5SY4410-6 5SY4410-7 5SY4410-8
5SY4313-5 5SY4313-6 5SY4313-7 5SY4313-8 5SY4613-5 5SY4613-6 5SY4613-7 5SY4613-8 5SY4413-5 5SY4413-6 5SY4413-7 5SY4413-8
– – 5SY4318-7 – – – – – – – – –
5SY4316-5 5SY4316-6 5SY4316-7 5SY4316-8 5SY4616-5 5SY4616-6 5SY4616-7 5SY4616-8 5SY4416-5 5SY4416-6 5SY4416-7 5SY4416-8
5SY4320-5 5SY4320-6 5SY4320-7 5SY4320-8 5SY4620-5 5SY4620-6 5SY4620-7 5SY4620-8 5SY4420-5 5SY4420-6 5SY4420-7 5SY4420-8
5SY4325-5 5SY4325-6 5SY4325-7 5SY4325-8 5SY4625-5 5SY4625-6 5SY4625-7 5SY4625-8 5SY4425-5 5SY4425-6 5SY4425-7 5SY4425-8
– – 5SY4330-7 – – – – – – – – –
5SY4332-5 5SY4332-6 5SY4332-7 5SY4332-8 5SY4632-5 5SY4632-6 5SY4632-7 5SY4632-8 5SY4432-5 5SY4432-6 5SY4432-7 5SY4432-8
– – 5SY4335-7 – – – – – – – – –
5SY4340-5 5SY4340-6 5SY4340-7 5SY4340-8 5SY4640-5 5SY4640-6 5SY4640-7 5SY4640-8 5SY4440-5 5SY4440-6 5SY4440-7 5SY4440-8
– – 5SY4345-7 – – – – – – – – –
5SY4350-5 5SY4350-6 5SY4350-7 5SY4350-8 5SY4650-5 5SY4650-6 5SY4650-7 5SY4650-8 5SY4450-5 5SY4450-6 5SY4450-7 5SY4450-8
– – 5SY4360-7 – – – – – – – – –
5SY4363-5 5SY4363-6 5SY4363-7 5SY4363-8 5SY4663-5 5SY4663-6 5SY4663-7 5SY4663-8 5SY4463-5 5SY4463-6 5SY4463-7 5SY4463-8
– 5SY4380-6 5SY4380-7 – – – 5SY4680-7 – – 5SY4480-6 5SY4480-7 –

Accessories
Auxiliary switches (AS) Article No. Arc fault detection units (AFDD) Article No.
1 NO + 1 NC Standard 5ST3010 For basic units 1P+N In up to 16 A 5SM6021-2
For low power 5ST3013 (2 MW) In up to 40 A 5SM6024-2
For low power (with diode) 5ST3013-0XX01 Undervoltage releases (UR) Article No.
2 NO Standard 5ST3011 With integrated 230 V AC 5ST3040
For low power 5ST3014 auxiliary switch 110 V DC 5ST3041
2 NC Standard 5ST3012 24 V DC 5ST3042
For low power 5ST3015 Without integrated 230 V AC 5ST3043
1 CO Standard 5ST3016 auxiliary switch 110 V DC 5ST3044
Fault signal contacts (FC) Article No. 24 V DC 5ST3045
1 NO + 1 NC 5ST3020 Remote controlled mechanisms (RC mech.) Article No.
2 NO 5ST3021 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
2 NC 5ST3022 177 … 270 V AC 5ST3054
Auxiliary switches and fault signal contacts (AS+FC) Article No. Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
1 CO (AS) + 1 CO (FC) 5ST3062 177 … 270 V AC 5ST3056
5ST3 COM (AS+FC) new 5ST3062-0MC Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Shunt trips (ST) Article No. 177 … 270 V AC 5ST3058
110 … 415 V AC, 110 … 220 DC 5ST3030 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
24 … 48 V AC/DC 5ST3031 function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
12 V DC 5ST3031-0XX01 Adapters for remote controlled mechanisms (RC mech.) Article No.
1–2 MW 5ST3820-1
3–4 MW 5ST3820-2

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/27
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SP4 miniature circuit breakers


10 kA

1P 2P
230/400 V AC 400 V AC
Mounting width 1.5 MW 3 MW
1 1 3

2 2 4
3 Rated current In Characteristic Characteristic
B C D B C D
80 A 5SP4180-6 5SP4180-7 5SP4180-8 5SP4280-6 5SP4280-7 5SP4280-8
100 A 5SP4191-6 5SP4191-7 5SP4191-8 5SP4291-6 5SP4291-7 5SP4291-8
125 A 5SP4192-6 5SP4192-7 – 5SP4292-6 5SP4292-7 –

Mounting concept
27 – 108 mm

36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

5SP4 RC mech. AS AS AS ST ST AS ST AS AS
basic unit and FC FC + FC UR UR + FC UR + FC + FC
AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC

Adapter

AS Auxiliary switches See page 3/46


FC Fault signal contacts See page 3/48
AS+FC Auxiliary switches and fault signal contacts See page 3/49
ST Shunt trips See page 3/52
UR Undervoltage releases See page 3/53
RC mech. Remote controlled mechanisms See page 3/54

Quick selection guide, page 3/8


3/28 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P 4P
400 V AC 400 V AC
4.5 MW 6 MW
1 3 5 1 3 5 7

2 4 6 2 4 6 8
Characteristic Characteristic 3
B C D B C D
5SP4380-6 5SP4380-7 5SP4380-8 5SP4480-6 5SP4480-7 5SP4480-8
5SP4391-6 5SP4391-7 5SP4391-8 5SP4491-6 5SP4491-7 5SP4491-8
5SP4392-6 5SP4392-7 – 5SP4492-6 5SP4492-7 –

Accessories
Auxiliary switches (AS) Article No. Undervoltage releases (UR) Article No.
1 NO + 1 NC Standard 5ST3010 With integrated 230 V AC 5ST3040
For low power 5ST3013 auxiliary switch 110 V DC 5ST3041
For low power (with diode) 5ST3013-0XX01 24 V DC 5ST3042
2 NO Standard 5ST3011 Without integrated 230 V AC 5ST3043
For low power 5ST3014 auxiliary switch 110 V DC 5ST3044
2 NC Standard 5ST3012 24 V DC 5ST3045
For low power 5ST3015 Remote controlled mechanisms (RC mech.) Article No.
1 CO Standard 5ST3016 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3056
1 NO + 1 NC 5ST3020 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
2 NO 5ST3021 177 … 270 V AC 5ST3058
2 NC 5ST3022 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
Auxiliary switches and fault signal contacts (AS+FC) Article No. function
1 CO (AS) + 1 CO (FC) 5ST3062 Adapters for remote controlled mechanisms (RC mech.) Article No.
5ST3 COM (AS+FC) new 5ST3062-0MC 1.5 MW 5ST3820-1
Shunt trips (ST) Article No. 3–6 MW 5ST3820-2
110 … 415 V AC, 110 … 220 DC 5ST3030
24 ... 48 V AC/DC 5ST3031
12 V DC 5ST3031-0XX01

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/29
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SY5 miniature circuit breakers


10 kA

1P 2P 4P
230/400 V AC, 220 V DC 400 V AC, 440 V DC 400 V AC, 880 V DC
Mounting width 1 MW 2 MW 4 MW
1 1 3 1 3 5 7

2 2 4 2 4 6 8
3 Rated current In Characteristic Characteristic Characteristic
B C B C B C
0.3 A – 5SY5114-7 – 5SY5214-7 – 5SY5414-7
0.5 A – 5SY5105-7 – 5SY5205-7 – 5SY5405-7
1A – 5SY5101-7 – 5SY5201-7 – 5SY5401-7
1.6 A – 5SY5115-7 – 5SY5215-7 – 5SY5415-7
2A 5SY5102-6 5SY5102-7 5SY5202-6 5SY5202-7 – 5SY5402-7
3A – 5SY5103-7 – 5SY5203-7 – 5SY5403-7
4A 5SY5104-6 5SY5104-7 5SY5204-6 5SY5204-7 – 5SY5404-7
6A 5SY5106-6 5SY5106-7 5SY5206-6 5SY5206-7 5SY5406-6 5SY5406-7
8A 5SY5108-6 5SY5108-7 5SY5208-6 5SY5208-7 – 5SY5408-7
10 A 5SY5110-6 5SY5110-7 5SY5210-6 5SY5210-7 5SY5410-6 5SY5410-7
13 A 5SY5113-6 5SY5113-7 5SY5213-6 5SY5213-7 5SY5413-6 5SY5413-7
16 A 5SY5116-6 5SY5116-7 5SY5216-6 5SY5216-7 5SY5416-6 5SY5416-7
20 A 5SY5120-6 5SY5120-7 5SY5220-6 5SY5220-7 5SY5420-6 5SY5420-7
25 A 5SY5125-6 5SY5125-7 5SY5225-6 5SY5225-7 5SY5425-6 5SY5425-7
32 A 5SY5132-6 5SY5132-7 5SY5232-6 5SY5232-7 5SY5432-6 5SY5432-7
40 A 5SY5140-6 5SY5140-7 5SY5240-6 5SY5240-7 5SY5440-6 5SY5440-7
50 A 5SY5150-6 5SY5150-7 5SY5250-6 5SY5250-7 5SY5450-6 5SY5450-7
63 A 5SY5163-6 5SY5163-7 5SY5263-6 5SY5263-7 5SY5463-6 5SY5463-7

Mounting concept
18 – 72 mm

27 – 36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

5SY5 RC mech. AS AS AS ST ST AS ST AS AS
basic unit and FC FC + FC UR UR + FC UR + FC + FC
AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC

Adapter

AS Auxiliary switches See page 3/46


FC Fault signal contacts See page 3/48
AS+FC Auxiliary switches and fault signal contacts See page 3/49
ST Shunt trips See page 3/52
UR Undervoltage releases See page 3/53
RC mech. Remote controlled mechanisms See page 3/54

Quick selection guide, page 3/8


3/30 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

Accessories
Auxiliary switches (AS) Article No. Undervoltage releases (UR) Article No.
1 NO + 1 NC Standard 5ST3010 With integrated 230 V AC 5ST3040
For low power 5ST3013 auxiliary switch 110 V DC 5ST3041
For low power (with diode) 5ST3013-0XX01 24 V DC 5ST3042
2 NO Standard 5ST3011 Without integrated 230 V AC 5ST3043
For low power 5ST3014 auxiliary switch 110 V DC 5ST3044
2 NC Standard 5ST3012 24 V DC 5ST3045
For low power 5ST3015 Remote controlled mechanisms (RC mech.) Article No.
1 CO Standard 5ST3016 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3054
1 NO + 1 NC 5ST3020 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
2 NO 5ST3021 177 … 270 V AC 5ST3056
2 NC 5ST3022 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Auxiliary switches and fault signal contacts (AS+FC) Article No. 177 … 270 V AC 5ST3058
1 CO (AS) + 1 CO (FC) 5ST3062 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
5ST3 COM (AS+FC) new 5ST3062-0MC function 170 … 277 V AC, 77 … 286 V DC5ST3071 new
Shunt trips (ST) Article No. Adapters for remote controlled mechanisms (RC mech.) Article No.
110 … 415 V AC, 110 … 220 DC 5ST3030 1–2 MW 5ST3820-1
24 ... 48 V AC/DC 5ST3031 4 MW 5ST3820-2
12 V DC 5ST3031-0XX01

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/31
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SY7 miniature circuit breakers


15 kA

1P 1P+N 2P
230/400 V AC 230 V AC 400 V AC
Mounting width 1 MW 2 MW 2 MW
1 1 N 1 3

2 2 N 2 4
3 Rated Main MCB, line Characteristic Characteristic Characteristic
­current In side of meter B C D B C D B C D
0.3 A – – 5SY7114-7 5SY7114-8 – 5SY7514-7 5SY7514-8 – 5SY7214-7 5SY7214-8
0.5 A – – 5SY7105-7 5SY7105-8 – 5SY7505-7 5SY7505-8 – 5SY7205-7 5SY7205-8
1A – – 5SY7101-7 5SY7101-8 – 5SY7501-7 5SY7501-8 – 5SY7201-7 5SY7201-8
1.6 A – – 5SY7115-7 5SY7115-8 – 5SY7515-7 5SY7515-8 – 5SY7215-7 5SY7215-8
2A – – 5SY7102-7 5SY7102-8 – 5SY7502-7 5SY7502-8 – 5SY7202-7 5SY7202-8
3A – – 5SY7103-7 5SY7103-8 – 5SY7503-7 5SY7503-8 – 5SY7203-7 5SY7203-8
4A – – 5SY7104-7 5SY7104-8 – 5SY7504-7 5SY7504-8 – 5SY7204-7 5SY7204-8
6A – 5SY7106-6 5SY7106-7 5SY7106-8 5SY7506-6 5SY7506-7 5SY7506-8 5SY7206-6 5SY7206-7 5SY7206-8
■ 5SY7106-6KK13 – – – – – – – –
8A – – 5SY7108-7 5SY7108-8 – 5SY7508-7 5SY7508-8 – 5SY7208-7 5SY7208-8
10 A – 5SY7110-6 5SY7110-7 5SY7110-8 5SY7510-6 5SY7510-7 5SY7510-8 5SY7210-6 5SY7210-7 5SY7210-8
■ 5SY7110-6KK13 – – – – – – – –
13 A – 5SY7113-6 5SY7113-7 5SY7113-8 5SY7513-6 5SY7513-7 5SY7513-8 5SY7213-6 5SY7213-7 5SY7213-8
16 A – 5SY7116-6 5SY7116-7 5SY7116-8 5SY7516-6 5SY7516-7 5SY7516-8 5SY7216-6 5SY7216-7 5SY7216-8
20 A – 5SY7120-6 5SY7120-7 5SY7120-8 5SY7520-6 5SY7520-7 5SY7520-8 5SY7220-6 5SY7220-7 5SY7220-8
25 A – 5SY7125-6 5SY7125-7 5SY7125-8 5SY7525-6 5SY7525-7 5SY7525-8 5SY7225-6 5SY7225-7 5SY7225-8
32 A – 5SY7132-6 5SY7132-7 5SY7132-8 5SY7532-6 5SY7532-7 5SY7532-8 5SY7232-6 5SY7232-7 5SY7232-8
40 A – 5SY7140-6 5SY7140-7 5SY7140-8 5SY7540-6 5SY7540-7 5SY7540-8 5SY7240-6 5SY7240-7 5SY7240-8
50 A – 5SY7150-6 5SY7150-7 5SY7150-8 5SY7550-6 5SY7550-7 5SY7550-8 5SY7250-6 5SY7250-7 5SY7250-8
63 A – 5SY7163-6 5SY7163-7 5SY7163-8 5SY7563-6 5SY7563-7 5SY7563-8 5SY7263-6 5SY7263-7 5SY7263-8

Mounting concept
18 mm

36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm
optionally optionally
or or or or
and and

AFDD 5SY7 AS AS AS ST ST AS ST AS AS
basic unit (1P+N) FC FC + FC UR UR + FC UR + FC + FC
up to max. 40 A AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC
18 – 72 mm

27 – 36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

5SY7 RC mech. AS AS AS ST ST AS ST AS AS
basic unit and FC FC + FC UR UR + FC UR + FC + FC
AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC

Adapter

AFDD Arc fault detection units See page 3/55 AS+FC Auxiliary switches and UR Undervoltage releases See page 3/53
AS Auxiliary switches See page 3/46 fault signal contacts See page 3/49 RC mech. Remote controlled mechanisms See page 3/54
FC Fault signal contacts See page 3/48 ST Shunt trips See page 3/52

Quick selection guide, page 3/8


3/32 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P 3P+N 4P
400 V AC 400 V AC 400 V AC
3 MW 4 MW 4 MW
1 3 5 1 3 5 N 1 3 5 7

2 4 6 2 4 6 N 2 4 6 8
Characteristic Characteristic Characteristic 3
B C D B C D B C D
– 5SY7314-7 5SY7314-8 – 5SY7614-7 5SY7614-8 – 5SY7414-7 5SY7414-8
– 5SY7305-7 5SY7305-8 – 5SY7605-7 5SY7605-8 – 5SY7405-7 5SY7405-8
– 5SY7301-7 5SY7301-8 – 5SY7601-7 5SY7601-8 – 5SY7401-7 5SY7401-8
– 5SY7315-7 5SY7315-8 – 5SY7615-7 5SY7615-8 – 5SY7415-7 5SY7415-8
– 5SY7302-7 5SY7302-8 – 5SY7602-7 5SY7602-8 – 5SY7402-7 5SY7402-8
– 5SY7303-7 5SY7303-8 – 5SY7603-7 5SY7603-8 – 5SY7403-7 5SY7403-8
– 5SY7304-7 5SY7304-8 – 5SY7604-7 5SY7604-8 – 5SY7404-7 5SY7404-8
5SY7306-6 5SY7306-7 5SY7306-8 5SY7606-6 5SY7606-7 5SY7606-8 5SY7406-6 5SY7406-7 5SY7406-8
– – – – – – – – –
– 5SY7308-7 5SY7308-8 – 5SY7608-7 5SY7608-8 – 5SY7408-7 5SY7408-8
5SY7310-6 5SY7310-7 5SY7310-8 5SY7610-6 5SY7610-7 5SY7610-8 5SY7410-6 5SY7410-7 5SY7410-8
– – – – – – – – –
5SY7313-6 5SY7313-7 5SY7313-8 5SY7613-6 5SY7613-7 5SY7613-8 5SY7413-6 5SY7413-7 5SY7413-8
5SY7316-6 5SY7316-7 5SY7316-8 5SY7616-6 5SY7616-7 5SY7616-8 5SY7416-6 5SY7416-7 5SY7416-8
5SY7320-6 5SY7320-7 5SY7320-8 5SY7620-6 5SY7620-7 5SY7620-8 5SY7420-6 5SY7420-7 5SY7420-8
5SY7325-6 5SY7325-7 5SY7325-8 5SY7625-6 5SY7625-7 5SY7625-8 5SY7425-6 5SY7425-7 5SY7425-8
5SY7332-6 5SY7332-7 5SY7332-8 5SY7632-6 5SY7632-7 5SY7632-8 5SY7432-6 5SY7432-7 5SY7432-8
5SY7340-6 5SY7340-7 5SY7340-8 5SY7640-6 5SY7640-7 5SY7640-8 5SY7440-6 5SY7440-7 5SY7440-8
5SY7350-6 5SY7350-7 5SY7350-8 5SY7650-6 5SY7650-7 5SY7650-8 5SY7450-6 5SY7450-7 5SY7450-8
5SY7363-6 5SY7363-7 5SY7363-8 5SY7663-6 5SY7663-7 5SY7663-8 5SY7463-6 5SY7463-7 5SY7463-8

Accessories
Auxiliary switches (AS) Article No. Undervoltage releases (UR) Article No.
1 NO + 1 NC Standard 5ST3010 With integrated 230 V AC 5ST3040
For low power 5ST3013 auxiliary switch 110 V DC 5ST3041
For low power (with diode) 5ST3013-0XX01 24 V DC 5ST3042
2 NO Standard 5ST3011 Without integrated 230 V AC 5ST3043
For low power 5ST3014 auxiliary switch 110 V DC 5ST3044
2 NC Standard 5ST3012 24 V DC 5ST3045
For low power 5ST3015 Remote controlled mechanisms (RC mech.) Article No.
1 CO Standard 5ST3016 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3054
1 NO + 1 NC 5ST3020 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
2 NO 5ST3021 177 … 270 V AC 5ST3056
2 NC 5ST3022 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Auxiliary switches and fault signal contacts (AS+FC) Article No. 177 … 270 V AC 5ST3058
1 CO (AS) + 1 CO (FC) 5ST3062 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
5ST3 COM (AS+FC) new 5ST3062-0MC function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
Shunt trips (ST) Article No. Adapters for remote controlled mechanisms (RC mech.) Article No.
110 … 415 V AC, 110 … 220 V DC 5ST3030 1–2 MW 5ST3820-1
24 … 48 V AC/DC 5ST3031 3–4 MW 5ST3820-2
12 V DC 5ST3031-0XX01 Arc fault detection units (AFDD) Article No.
For basic units 1P+N In up to 16 A 5SM6021-2
(2 MW) In up to 40 A 5SM6024-2

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/33
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SY8 miniature circuit breakers


25 kA

1P 1P+N 2P 3P
230/400 V AC 230 V AC 400 V AC 400 V AC
Mounting width 1 MW 2 MW 2 MW 3 MW
1 1 N 1 3 1 3 5

3 2 2 N 2 4 2 4 6
Rated current In Characteristic Characteristic Characteristic Characteristic
C D C D C D C D
0.3 A 5SY8114-7 5SY8114-8 5SY8514-7 5SY8514-8 5SY8214-7 5SY8214-8 5SY8314-7 5SY8314-8
0.5 A 5SY8105-7 5SY8105-8 5SY8505-7 5SY8505-8 5SY8205-7 5SY8205-8 5SY8305-7 5SY8305-8
1A 5SY8101-7 5SY8101-8 5SY8501-7 5SY8501-8 5SY8201-7 5SY8201-8 5SY8301-7 5SY8301-8
1.6 A 5SY8115-7 5SY8115-8 5SY8515-7 5SY8515-8 5SY8215-7 5SY8215-8 5SY8315-7 5SY8315-8
2A 5SY8102-7 5SY8102-8 5SY8502-7 5SY8502-8 5SY8202-7 5SY8202-8 5SY8302-7 5SY8302-8
3A 5SY8103-7 5SY8103-8 5SY8503-7 5SY8503-8 5SY8203-7 5SY8203-8 5SY8303-7 5SY8303-8
4A 5SY8104-7 5SY8104-8 5SY8504-7 5SY8504-8 5SY8204-7 5SY8204-8 5SY8304-7 5SY8304-8
6A 5SY8106-7 5SY8106-8 5SY8506-7 5SY8506-8 5SY8206-7 5SY8206-8 5SY8306-7 5SY8306-8
8A 5SY8108-7 5SY8108-8 5SY8508-7 5SY8508-8 5SY8208-7 5SY8208-8 5SY8308-7 5SY8308-8
10 A 5SY8110-7 5SY8110-8 5SY8510-7 5SY8510-8 5SY8210-7 5SY8210-8 5SY8310-7 5SY8310-8
12.5 A – – – – – – – –
13 A 5SY8113-7 5SY8113-8 5SY8513-7 5SY8513-8 5SY8213-7 5SY8213-8 5SY8313-7 5SY8313-8
16 A 5SY8116-7 5SY8116-8 5SY8516-7 5SY8516-8 5SY8216-7 5SY8216-8 5SY8316-7 5SY8316-8
20 A 5SY8120-7 5SY8120-8 5SY8520-7 5SY8520-8 5SY8220-7 5SY8220-8 5SY8320-7 5SY8320-8
25 A 5SY8125-7 5SY8125-8 5SY8525-7 5SY8525-8 5SY8225-7 5SY8225-8 5SY8325-7 5SY8325-8
32 A 5SY8132-7 5SY8132-8 5SY8532-7 5SY8532-8 5SY8232-7 5SY8232-8 5SY8332-7 5SY8332-8
40 A 5SY8140-7 5SY8140-8 5SY8540-7 5SY8540-8 5SY8240-7 5SY8240-8 5SY8340-7 5SY8340-8
50 A 5SY8150-7 5SY8150-8 5SY8550-7 5SY8550-8 5SY8250-7 5SY8250-8 5SY8350-7 5SY8350-8
63 A 5SY8163-7 5SY8163-8 5SY8563-7 5SY8563-8 5SY8263-7 5SY8263-8 5SY8363-7 5SY8363-8

Mounting concept
36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm
optionally
or or or or
and

5SY8 AS AS AS ST ST AS ST AS AS
basic unit FC FC + FC UR UR + FC UR + FC + FC
(1P+N) AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC
18 – 72 mm

27 – 36 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally optionally
or or or or
and and

5SY8 RC mech. AS AS AS ST ST AS ST AS AS
basic unit and FC FC + FC UR UR + FC UR + FC + FC
AS+FC AS+FC AS+FC AS+FC AS+FC AS+FC

Adapter

AFDD Arc fault detection units See page 3/55 AS+FC Auxiliary switches and UR Undervoltage releases See page 3/53
AS Auxiliary switches See page 3/46 fault signal contacts See page 3/49 RC mech. Remote controlled mechanisms See page 3/54
FC Fault signal contacts See page 3/48 ST Shunt trips See page 3/52

Quick selection guide, page 3/8


3/34 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

3P+N 4P
400 V AC 400 V AC
4 MW 4 MW
1 3 5 N 1 3 5 7

2 4 6 N 2 4 6 8 3
Characteristic Characteristic
C D C D
5SY8614-7 5SY8614-8 5SY8414-7 5SY8414-8
5SY8605-7 5SY8605-8 5SY8405-7 5SY8405-8
5SY8601-7 5SY8601-8 5SY8401-7 5SY8401-8
5SY8615-7 5SY8615-8 5SY8415-7 5SY8415-8
5SY8602-7 5SY8602-8 5SY8402-7 5SY8402-8
5SY8603-7 5SY8603-8 5SY8403-7 5SY8403-8
5SY8604-7 5SY8604-8 5SY8404-7 5SY8404-8
5SY8606-7 5SY8606-8 5SY8406-7 5SY8406-8
5SY8608-7 5SY8608-8 5SY8408-7 5SY8408-8
5SY8610-7 5SY8610-8 5SY8410-7 5SY8410-8
– – – –
5SY8613-7 5SY8613-8 5SY8413-7 5SY8413-8
5SY8616-7 5SY8616-8 5SY8416-7 5SY8416-8
5SY8620-7 5SY8620-8 5SY8420-7 5SY8420-8
5SY8625-7 5SY8625-8 5SY8425-7 5SY8425-8
5SY8632-7 5SY8632-8 5SY8432-7 5SY8432-8
5SY8640-7 5SY8640-8 5SY8440-7 5SY8440-8
5SY8650-7 5SY8650-8 5SY8450-7 5SY8450-8
5SY8663-7 5SY8663-8 5SY8463-7 5SY8463-8

Accessories
Auxiliary switches (AS) Article No. Undervoltage releases (UR) Article No.
1 NO + 1 NC Standard 5ST3010 With integrated 230 V AC 5ST3040
For low power 5ST3013 auxiliary switch 110 V DC 5ST3041
For low power (with diode) 5ST3013-0XX01 24 V DC 5ST3042
2 NO Standard 5ST3011 Without integrated 230 V AC 5ST3043
For low power 5ST3014 auxiliary switch 110 V DC 5ST3044
2 NC Standard 5ST3012 24 V DC 5ST3045
For low power 5ST3015 Remote controlled mechanisms (RC mech.) Article No.
1 CO Standard 5ST3016 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3054
1 NO + 1 NC 5ST3020 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
2 NO 5ST3021 177 … 270 V AC 5ST3056
2 NC 5ST3022 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Auxiliary switches and fault signal contacts (AS+FC) Article No. 177 … 270 V AC 5ST3058
1 CO (AS) + 1 CO (FC) 5ST3062 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
5ST3 COM (AS+FC) new 5ST3062-0MC function 170 … 277 V AC, 77 … 286 V DC5ST3071 new
Shunt trips (ST) Article No. Adapters for remote controlled mechanisms (RC mech.) Article No.
110 … 415 V AC, 110 … 220 V DC 5ST3030 1–2 MW 5ST3820-1
24 … 48 V AC/DC 5ST3031 3–4 MW 5ST3820-2
12 V DC 5ST3031-0XX01

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/35
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SJ4..HG.. miniature circuit breakers


According to UL489, 14/10 kA

1P "same polarity only" 1P


240 V AC 240 V AC 240 V AC 240 V AC 480Y/277 V AC 240 V AC 480Y/277 V AC
Mounting width 1 MW 1 MW
1 1

2 2
3 Rated current In Characteristic Characteristic
B C D C C D D
0.3 A – 5SJ4114-7HG40 5SJ4114-8HG40 5SJ4114-7HG41 5SJ4114-7HG42 5SJ4114-8HG41 5SJ4114-8HG42
0.5 A – 5SJ4105-7HG40 5SJ4105-8HG40 5SJ4105-7HG41 5SJ4105-7HG42 5SJ4105-8HG41 5SJ4105-8HG42
1A – 5SJ4101-7HG40 5SJ4101-8HG40 5SJ4101-7HG41 5SJ4101-7HG42 5SJ4101-8HG41 5SJ4101-8HG42
1.6 A – 5SJ4115-7HG40 5SJ4115-8HG40 5SJ4115-7HG41 5SJ4115-7HG42 5SJ4115-8HG41 5SJ4115-8HG42
2A – 5SJ4102-7HG40 5SJ4102-8HG40 5SJ4102-7HG41 5SJ4102-7HG42 5SJ4102-8HG41 5SJ4102-8HG42
3A – 5SJ4103-7HG40 5SJ4103-8HG40 5SJ4103-7HG41 5SJ4103-7HG42 5SJ4103-8HG41 5SJ4103-8HG42
4A – 5SJ4104-7HG40 5SJ4104-8HG40 5SJ4104-7HG41 5SJ4104-7HG42 5SJ4104-8HG41 5SJ4104-8HG42
5A – 5SJ4111-7HG40 5SJ4111-8HG40 5SJ4111-7HG41 5SJ4111-7HG42 5SJ4111-8HG41 5SJ4111-8HG42
6A 5SJ4106-6HG40 5SJ4106-7HG40 5SJ4106-8HG40 5SJ4106-7HG41 5SJ4106-7HG42 5SJ4106-8HG41 5SJ4106-8HG42
8A – 5SJ4108-7HG40 5SJ4108-8HG40 5SJ4108-7HG41 5SJ4108-7HG42 5SJ4108-8HG41 5SJ4108-8HG42
10 A 5SJ4110-6HG40 5SJ4110-7HG40 5SJ4110-8HG40 5SJ4110-7HG41 5SJ4110-7HG42 5SJ4110-8HG41 5SJ4110-8HG42
13 A 5SJ4113-6HG40 5SJ4113-7HG40 5SJ4113-8HG40 5SJ4113-7HG41 5SJ4113-7HG42 5SJ4113-8HG41 5SJ4113-8HG42
15 A 5SJ4118-6HG40 5SJ4118-7HG40 5SJ4118-8HG40 5SJ4118-7HG41 5SJ4118-7HG42 5SJ4118-8HG41 5SJ4118-8HG42
16 A 5SJ4116-6HG40 5SJ4116-7HG40 5SJ4116-8HG40 5SJ4116-7HG41 5SJ4116-7HG42 5SJ4116-8HG41 5SJ4116-8HG42
20 A 5SJ4120-6HG40 5SJ4120-7HG40 5SJ4120-8HG40 5SJ4120-7HG41 5SJ4120-7HG42 5SJ4120-8HG41 5SJ4120-8HG42
25 A 5SJ4125-6HG40 5SJ4125-7HG40 5SJ4125-8HG40 5SJ4125-7HG41 5SJ4125-7HG42 5SJ4125-8HG41 5SJ4125-8HG42
30 A 5SJ4130-6HG40 5SJ4130-7HG40 5SJ4130-8HG40 5SJ4130-7HG41 5SJ4130-7HG42 5SJ4130-8HG41 5SJ4130-8HG42
32 A 5SJ4132-6HG40 5SJ4132-7HG40 5SJ4132-8HG40 5SJ4132-7HG41 5SJ4132-7HG42 5SJ4132-8HG41 5SJ4132-8HG42
35 A 5SJ4135-6HG40 5SJ4135-7HG40 5SJ4135-8HG40 5SJ4135-7HG41 5SJ4135-7HG42 5SJ4135-8HG41 –
40 A 5SJ4140-6HG40 5SJ4140-7HG40 5SJ4140-8HG40 5SJ4140-7HG41 5SJ4140-7HG42 5SJ4140-8HG41 –
45 A 5SJ4145-6HG40 5SJ4145-7HG40 5SJ4145-8HG40 5SJ4145-7HG41 – 5SJ4145-8HG41 –
50 A 5SJ4150-6HG40 5SJ4150-7HG40 5SJ4150-8HG40 5SJ4150-7HG41 – 5SJ4150-8HG41 –
60 A 5SJ4160-6HG40 5SJ4160-7HG40 5SJ4160-8HG40 5SJ4160-7HG41 – 5SJ4160-8HG41 –
63 A 5SJ4163-6HG40 5SJ4163-7HG40 5SJ4163-8HG40 5SJ4163-7HG41 – 5SJ4163-8HG41 –

Mounting concept
18 – 54 mm

18 mm

18 mm

18 mm
9 mm

9 mm
9 mm

9 mm

9 mm
9 mm

optionally
or or or or
and

5SJ4..HG.. AS AS AS ST ST AS ST AS AS
+ + + +
basic unit FC FC FC FC FC FC

AS Auxiliary switches See page 3/46


FC Fault signal contacts See page 3/48
ST Shunt trips See page 3/52

Quick selection guide, page 3/8


3/36 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

2P 3P
240 V AC 480Y/277 V AC 240 V AC 480Y/277 V AC 240 V AC 480Y/277 V AC 240 V AC 480Y/277 V AC
2 MW 3 MW
1 3 1 3 5

2 4 2 4 6
Characteristic Characteristic 3
C C D D C C D D
5SJ4214-7HG41 5SJ4214-7HG42 5SJ4214-8HG41 5SJ4214-8HG42 5SJ4314-7HG41 5SJ4314-7HG42 5SJ4314-8HG41 5SJ4314-8HG42
5SJ4205-7HG41 5SJ4205-7HG42 5SJ4205-8HG41 5SJ4205-8HG42 5SJ4305-7HG41 5SJ4305-7HG42 5SJ4305-8HG41 5SJ4305-8HG42
5SJ4201-7HG41 5SJ4201-7HG42 5SJ4201-8HG41 5SJ4201-8HG42 5SJ4301-7HG41 5SJ4301-7HG42 5SJ4301-8HG41 5SJ4301-8HG42
5SJ4215-7HG41 5SJ4215-7HG42 5SJ4215-8HG41 5SJ4215-8HG42 5SJ4315-7HG41 5SJ4315-7HG42 5SJ4315-8HG41 5SJ4315-8HG42
5SJ4202-7HG41 5SJ4202-7HG42 5SJ4202-8HG41 5SJ4202-8HG42 5SJ4302-7HG41 5SJ4302-7HG42 5SJ4302-8HG41 5SJ4302-8HG42
5SJ4203-7HG41 5SJ4203-7HG42 5SJ4203-8HG41 5SJ4203-8HG42 5SJ4303-7HG41 5SJ4303-7HG42 5SJ4303-8HG41 5SJ4303-8HG42
5SJ4204-7HG41 5SJ4204-7HG42 5SJ4204-8HG41 5SJ4204-8HG42 5SJ4304-7HG41 5SJ4304-7HG42 5SJ4304-8HG41 5SJ4304-8HG42
5SJ4211-7HG41 5SJ4211-7HG42 5SJ4211-8HG41 5SJ4211-8HG42 5SJ4311-7HG41 5SJ4311-7HG42 5SJ4311-8HG41 5SJ4311-8HG42
5SJ4206-7HG41 5SJ4206-7HG42 5SJ4206-8HG41 5SJ4206-8HG42 5SJ4306-7HG41 5SJ4306-7HG42 5SJ4306-8HG41 5SJ4306-8HG42
5SJ4208-7HG41 5SJ4208-7HG42 5SJ4208-8HG41 5SJ4208-8HG42 5SJ4308-7HG41 5SJ4308-7HG42 5SJ4308-8HG41 5SJ4308-8HG42
5SJ4210-7HG41 5SJ4210-7HG42 5SJ4210-8HG41 5SJ4210-8HG42 5SJ4310-7HG41 5SJ4310-7HG42 5SJ4310-8HG41 5SJ4310-8HG42
5SJ4213-7HG41 5SJ4213-7HG42 5SJ4213-8HG41 5SJ4213-8HG42 5SJ4313-7HG41 5SJ4313-7HG42 5SJ4313-8HG41 5SJ4313-8HG42
5SJ4218-7HG41 5SJ4218-7HG42 5SJ4218-8HG41 5SJ4218-8HG42 5SJ4318-7HG41 5SJ4318-7HG42 5SJ4318-8HG41 5SJ4318-8HG42
5SJ4216-7HG41 5SJ4216-7HG42 5SJ4216-8HG41 5SJ4216-8HG42 5SJ4316-7HG41 5SJ4316-7HG42 5SJ4316-8HG41 5SJ4316-8HG42
5SJ4220-7HG41 5SJ4220-7HG42 5SJ4220-8HG41 5SJ4220-8HG42 5SJ4320-7HG41 5SJ4320-7HG42 5SJ4320-8HG41 5SJ4320-8HG42
5SJ4225-7HG41 5SJ4225-7HG42 5SJ4225-8HG41 5SJ4225-8HG42 5SJ4325-7HG41 5SJ4325-7HG42 5SJ4325-8HG41 5SJ4325-8HG42
5SJ4230-7HG41 5SJ4230-7HG42 5SJ4230-8HG41 5SJ4230-8HG42 5SJ4330-7HG41 5SJ4330-7HG42 5SJ4330-8HG41 5SJ4330-8HG42
5SJ4232-7HG41 5SJ4232-7HG42 5SJ4232-8HG41 5SJ4232-8HG42 5SJ4332-7HG41 5SJ4332-7HG42 5SJ4332-8HG41 5SJ4332-8HG42
5SJ4235-7HG41 5SJ4235-7HG42 5SJ4235-8HG41 – 5SJ4335-7HG41 5SJ4335-7HG42 5SJ4335-8HG41 –
5SJ4240-7HG41 5SJ4240-7HG42 5SJ4240-8HG41 – 5SJ4340-7HG41 5SJ4340-7HG42 5SJ4340-8HG41 –
5SJ4245-7HG41 – 5SJ4245-8HG41 – 5SJ4345-7HG41 – 5SJ4345-8HG41 –
5SJ4250-7HG41 – 5SJ4250-8HG41 – 5SJ4350-7HG41 – 5SJ4350-8HG41 –
5SJ4260-7HG41 – 5SJ4260-8HG41 – 5SJ4360-7HG41 – 5SJ4360-8HG41 –
5SJ4263-7HG41 – 5SJ4263-8HG41 – 5SJ4363-7HG41 – 5SJ4363-8HG41 –

Accessories
Auxiliary switches (AS) acc. to UL 489 Article No.
1 NO + 1 NC 5ST3010-0HG
2 NO 5ST3011-0HG
2 NC 5ST3012-0HG
Fault signal contacts (FC) acc. to UL 489 Article No.
1 NO + 1 NC 5ST3020-0HG
2 NO 5ST3021-0HG
2 NC 5ST3022-0HG
Shunt trips (ST) acc. to UL 489 Article No.
110 … 415 V AC, 110 … 220 V DC 5ST3030-0HG
24 ... 48 V AC/DC 5ST3031-0HG

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/37
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SL6 COM miniature circuit breakers with


communication and measuring function new
1P+N 6 kA compact miniature circuit breakers
1P+N (N pole right) Mounting concept
230 V AC
Mounting 1 MW
width

18 mm

18 mm
optionally optionally

9 mm

9 mm
9 mm
or
1 N and and

3
AFDD 5SL60 AS AS AS
2 N basic unit FC FC + FC
Rated Characteristic (not for KL types) AS+FC AS+FC AS+FC
current In B C
2A 5SL6002-6MC 5SL6002-7MC
4A 5SL6004-6MC 5SL6004-7MC
6A 5SL6006-6MC 5SL6006-7MC

27 – 36 mm
8A – 5SL6008-7MC

18 mm
optionally optionally

9 mm

9 mm
9 mm
or
10 A 5SL6010-6MC 5SL6010-7MC and and
13 A 5SL6013-6MC 5SL6013-7MC
16 A 5SL6016-6MC 5SL6016-7MC
20 A 5SL6020-6MC 5SL6020-7MC 5SL60 RC mech. AS AS AS
25 A 5SL6025-6MC 5SL6025-7MC basic unit and FC FC + FC
AS+FC AS+FC AS+FC
32 A 5SL6032-6MC 5SL6032-7MC
Adapter

Note:
Please note the country-specific radio licenses of the products in SIOS:
www.siemens.com/lowvoltage/certificates

Accessories
Auxiliary switches (AS) Article No. Remote controlled mechanisms (RC mech.) Article No.
1 NO + 1 NC Standard 5ST3010 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
For low power 5ST3013 177 … 270 V AC 5ST3054
For low power (with diode) 5ST3013-0XX01 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
2 NO Standard 5ST3011 177 … 270 V AC 5ST3056
For low power 5ST3014 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
2 NC Standard 5ST3012 177 … 270 V AC 5ST3058
For low power 5ST3015 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
1 CO Standard 5ST3016 function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
Fault signal contacts (FC) Article No. Adapters for remote controlled mechanisms (RC mech.) Article No.
1 NO + 1 NC 5ST3020 1 MW 5ST3820-6
2 NO 5ST3021 Arc fault detection units (AFDD) Article No.
2 NC 5ST3022 For basic units 1P + N (1 In up to 16 A 5SM6011-2
Auxiliary switches and fault signal contacts (AS+FC) Article No. MW), In up to 40 A 5SM6014-2
1 CO (AS) + 1 CO (FC) 5ST3062 not for KL types
5ST3 COM (AS+FC) new 5ST3062-0MC

AFDD Arc fault detection units See page 3/55 AS+FC Auxiliary switches and fault signal contacts See page 3/49
AS Auxiliary switches See page 3/46 RC mech. Remote controlled mechanisms See page 3/54
FC Fault signal contacts See page 3/48

Quick selection guide, page 3/8


3/38 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

7KN Powercenter 1000 data transceiver

• Wireless radio transmission of


SENTRON SENTRON
powerconfig powerconfig mobile measured values and data to the
or other 7KN Powercenter 1000 data
Software
Solutions
transceiver 3
• Commissioning, parameter assign-
Modbus TCP ment, firmware updates and
further processing of the data via
the 7KN Powercenter 1000 data
transceiver

7KN Powercenter 1000 Article No.


I201_20143

7KN1110-0MC00
7KN Powercenter 1000
See page 10/17
You will find further information under:
Installation manual – Circuit
protection devices with
... ... ... ... communication and measuring
function (109791805)
System manual – Circuit protection
5SL6 COM 5ST3 COM 5SV6 COM 3NA COM
MCB AS+FC AFDD Fuse devices with communication and
max. 24 measuring function (109791806)
Wireless Protocol

Monitoring functions with limit monitoring


• Trip monitoring • Limit values for:
• Counters incl. limit monitoring for: − Overcurrent alarm 1 and alarm 2
− Operating hours − Undercurrent alarm 1 and alarm 2
− Operating hours with load current − Temperature
− Operating cycles (ON/OFF))
− Tripping operations
− Short circuits

Measured values Unit Memory


Temperature °C 1 hour in 1-minute intervals; 7 days in 15-minute intervals
Average temperature °C
Current A Min. and max. values over 10 days; 1 hour in 10-second intervals; 7 days in 15-minute intervals
Average current A
Maximum current A
Voltage V Min. and max. values over 10 days
Line frequency Hz Min. and max. values over 10 days
Active power W Min. and max. values over 10 days
Apparent power VA Min. and max. values over 10 days
Reactive power Var
Power factor
Active energy imported Wh 7 days in 15-minute intervals; 30 days in 1-day intervals
Active energy exported Wh
Reactive energy imported Varh
Reactive energy exported Varh

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/39
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SP3 selective main miniature


circuit breakers (SHU)
25 kA, mounting on a 40 mm busbar
1P 3× 1P
230/400 V AC 230/400 V AC
Mounting width 1.5 MW 4.5 MW
1 1 3 5

S S S S
3 2 2 4 6

Rated current In Characteristic Characteristic


E E
L1 L2 L3 L1 + L2 + L3
16 A 5SP3716-2KK01 5SP3716-2KK02 5SP3716-2KK03 5SP3716-2 5SP3816-2
20 A 5SP3720-2KK01 5SP3720-2KK02 5SP3720-2KK03 5SP3720-2 5SP3820-2
25 A 5SP3725-2KK01 5SP3725-2KK02 5SP3725-2KK03 5SP3725-2 5SP3825-2
35 A 5SP3735-2KK01 5SP3735-2KK02 5SP3735-2KK03 5SP3735-2 5SP3835-2
40 A 5SP3740-2KK01 5SP3740-2KK02 5SP3740-2KK03 5SP3740-2 5SP3840-2
50 A 5SP3750-2KK01 5SP3750-2KK02 5SP3750-2KK03 5SP3750-2 5SP3850-2
63 A 5SP3763-2KK01 5SP3763-2KK02 5SP3763-2KK03 5SP3763-2 5SP3863-2

Quick selection guide, page 3/8


3/40 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

25 kA, mounting on a mounting rail


1P 3× 1P 2P 3P 4P
230/400 V AC 230/400 V AC 230/400 V AC 230/400 V AC 230/400 V AC
Mounting width 1.5 MW 4.5 MW 3 MW 4.5 MW 6 MW
1 1 3 5 1 3 1 1 1 1 3 5 7

S S S S S S S S S S S S S
2 2 4 6 2 4 2 2 2 2 4 6 8
3
Rated current In Characteristic Characteristic Characteristic Characteristic Characteristic
E E E E E
16 A 5SP3716-3 5SP3816-3 5SP3216-3 5SP3316-3 5SP3416-3
20 A 5SP3720-3 5SP3820-3 5SP3220-3 5SP3320-3 5SP3420-3
25 A 5SP3725-3 5SP3825-3 5SP3225-3 5SP3325-3 5SP3425-3
35 A 5SP3735-3 5SP3835-3 5SP3235-3 5SP3335-3 5SP3435-3
40 A 5SP3740-3 5SP3840-3 5SP3240-3 5SP3340-3 5SP3440-3
50 A 5SP3750-3 5SP3850-3 5SP3250-3 5SP3350-3 5SP3450-3
63 A 5SP3763-3 5SP3863-3 5SP3263-3 5SP3363-3 5SP3463-3

Quick selection guide, page 3/8


Siemens LV 10 · 10/2021 3/41
© Siemens 2021
Miniature Circuit Breakers | Basic units

5SY17 device protection switches


Electromechanical

1P+AS
230 V AC/12 … 72 V DC
Mounting width 1 MW (18 mm)
1 13

2 14
3 Rated current In Characteristic
F1 (quick) F2 (slow)
0.5 A 5SY1705-2 5SY1705-4
1A 5SY1701-2 5SY1701-4
2A 5SY1702-2 5SY1702-4
4A 5SY1704-2 5SY1704-4
6A 5SY1706-2 5SY1706-4
8A 5SY1708-2 5SY1708-4
10 A 5SY1710-2 5SY1710-4
16 A 5SY1716-2 5SY1716-4

Mounting concept
27 – 36 mm
18 mm

9 mm

9 mm
9 mm

optionally optionally
or
and and

5SY17 RC mech. AS AS AS
basic unit and FC FC + FC
AS+FC AS+FC AS+FC

Adapter

AS Auxiliary switches See page 3/46


FC Fault signal contacts See page 3/48
AS+FC Auxiliary switches and fault signal contacts See page 3/49
RC mech. Remote controlled mechanisms See page 3/54

Accessories
Auxiliary switches (AS) Article No. Auxiliary switches and fault signal contacts (AS+FC) Article No.
1 NO + 1 NC Standard 5ST3010 1 CO (AS) + 1 CO (FC) 5ST3062
For low power 5ST3013 5ST3 COM (AS+FC) new 5ST3062-0MC
For low power (with diode) 5ST3013-0XX01 Remote controlled mechanisms (RC mech.) Article No.
2 NO Standard 5ST3011 Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053
For low power 5ST3014 177 … 270 V AC 5ST3054
2 NC Standard 5ST3012 Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055
For low power 5ST3015 177 … 270 V AC 5ST3056
1 CO Standard 5ST3016 Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057
Fault signal contacts (FC) Article No. 177 … 270 V AC 5ST3058
1 NO + 1 NC 5ST3020 Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070
2 NO 5ST3021 function 170 … 277 V AC, 77 … 286 V DC 5ST3071 new
2 NC 5ST3022 Adapters for remote controlled mechanisms (RC mech.) Article No.
1 MW 5ST3820-6

Quick selection guide, page 3/10


3/42 Siemens LV 10 · 10/2021
© Siemens 2021
Basic units | Miniature Circuit Breakers

5SK9 device protection switches


Electronic

1P+AS
24 V DC
Mounting width 6.2 mm
1 13

2 14
Rated current In 3
1A 5SK9101-1
2A 5SK9102-1
3A 5SK9103-1
4A 5SK9104-1
6A 5SK9106-1
8A 5SK9108-1

Specific accessories
Connecting combs
Type Number of poles Max. load current Imax Article No.
For parallel infeed 2-pole 24 A 8WH9020-6BC10
32 A 8WH9020-6CC10
5-pole 24 A 8WH9020-6BF10
32 A 8WH9020-6CF10
For remote signal – group signal 2-pole 32 A 8WH9020-6CC10
Reducing combs for 10 mm2 terminal blocks
Type Number of poles Max. load current Imax Article No.
For bypassing the power supply 2-pole 40 A 8WH9020-0AC10

See general accessories from page 3/56 onwards

Quick selection guide, page 3/10


Siemens LV 10 · 10/2021 3/43
© Siemens 2021
Miniature Circuit Breakers | Accessories

Overview of the modular system


Miniature circuit breakers

5SL60/
5SL3 5SL6 5SL4 5SJ6...-.KS 5SL30 5SY
5SL6 COM
Auxiliary switches (AS) Article No.
1 NO + 1 NC Standard 5ST3010 ■ ■ ■ – ■ ■ ■
3 For low power 5ST3013 ■ ■ ■ – ■ ■ ■
For low power (with diode) 5ST3013-0XX01 ■ ■ ■ – ■ ■ ■
2 NO Standard 5ST3011 ■ ■ ■ – ■ ■ ■
For low power 5ST3014 ■ ■ ■ – ■ ■ ■
2 NC Standard 5ST3012 ■ ■ ■ – ■ ■ ■
For low power 5ST3015 ■ ■ ■ – ■ ■ ■
1 CO Standard 5ST3016 ■ ■ ■ – ■ ■ ■
5ST1010-0FP – – – – – – –
Fault signal contacts (FC) Article No.
1 NO + 1 NC 5ST3020 ■ ■ ■ – ■ ■ ■
2 NO 5ST3021 ■ ■ ■ – ■ ■ ■
2 NC 5ST3022 ■ ■ ■ – ■ ■ ■

Auxiliary switches and fault signal contacts (AS+FC) Article No.


1 CO (AS) + Standard 5ST3062 ■ ■ ■ – ■ ■ ■
1 CO (FC)
5ST3 COM (AS+FC) new With communication and 5ST3062-0MC ■ ■ ■ – ■ ■ ■
measuring function

Shunt trips (ST) Article No.


110 ... 415 V AC, 110 ... 220 V DC 5ST3030 – – ■ – – – ■
24 ... 48 V AC/DC 5ST3031 – – ■ – – – ■
12 V DC 5ST3031-0XX01 – – ■ – – – ■

Undervoltage releases (UR) Article No.


With integrated auxiliary 230 V AC 5ST3040 – – ■ – – – ■
switch 110 V DC 5ST3041 – – ■ – – – ■
24 V DC 5ST3042 – – ■ – – – ■
Without integrated auxiliary 230 V AC 5ST3043 – – ■ – – – ■
switch 110 V DC 5ST3044 – – ■ – – – ■
24 V DC 5ST3045 – – ■ – – – ■
Remote controlled mechanisms (RC mech.) Article No.
Basic 12 ... 30 V AC, 12 ... 48 V DC 5ST3053 – ■ ■ – – ■ ■
177 … 270 V AC 5ST3054 – ■ ■ – – ■ ■
Power 12 ... 30 V AC, 12 ... 48 V DC 5ST3055 – ■ ■ – – ■ ■
177 … 270 V AC 5ST3056 – ■ ■ – – ■ ■
Power with ARD 12 ... 30 V AC, 12 ... 48 V DC 5ST3057 – ■ ■ – – ■ ■
177 … 270 V AC 5ST3058 – ■ ■ – – ■ ■
Power with extended 12 ... 30 V AC, 12 ... 48 V DC 5ST3070 – ■ ■ – – ■ ■
function 170 ... 277 V AC, 77 ... 286 V DC 5ST3071 new – ■ ■ – – ■ ■
5SM6 arc fault detection units Article No.
Rated current up to 16 A Standard 5SM6021-2 – – □ – – – □
For compact devices 1P+N in 1 5SM6011-2 – – – – – □ –
MW
Rated current up to 40 A Standard 5SM6024-2 – – □ – – – □
For compact devices 1P+N in 1 5SM6014-2 – – – – – □ –
MW
Standard busbars Article No.
Cannot be cut 5ST36.. ■ ■ ■ ■ ■ ■ ■
Can be cut 5ST37.. ■ ■ ■ ■ ■ ■ ■
Compact busbars Article No.
Cannot be cut 5ST36.. □ □ □ – ■ ■ –
Can be cut 5ST37.. □ □ □ – ■ ■ –
From page 3/12

■ Suitable for all versions □ Suitable for some versions

System overview, page 3/5


3/44 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

Device protection switches Arc fault detection


devices Switching​
Residual current protective devices devices

5SM2 +  5SM2 +  5SU1 5SU1...FP/ 5SV6/


5SP4 5SJ4..HG.. 5SY17 5SV 5SU1 5SV1 5SM6 5TE8 5TL
LS 5SP4 (125 A) FR 5SV6 COM

■ ...-0HG ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■
■ – ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■ 3
■ – ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■
■ ...-0HG ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■
■ – ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■
■ ...-0HG ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■
■ – ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■
■ – ■ ■ ■ ■ ■ ■ – ■ □ ■ ■ ■
– – – – – – – – ■ – – – – –

■ ...-0HG ■ ■ ■ ■ ■ ■ – ■ □ ■ – –
■ ...-0HG ■ ■ ■ ■ ■ ■ – ■ □ ■ – –
■ ...-0HG ■ ■ ■ ■ ■ ■ – ■ □ ■ – –

■ – ■ ■ ■ ■ ■ ■ – ■ □ ■ – –

■ – ■ ■ ■ ■ ■ ■ – ■ □ ■ – –

■ ...-0HG – ■ ■ ■ ■ ■ – – □ – – –
■ ...-0HG – ■ ■ ■ ■ ■ – – □ – – –
■ – – ■ ■ ■ ■ ■ – – □ – – –

■ – – ■ ■ ■ ■ ■ – – □ – – –
■ – – ■ ■ ■ ■ ■ – – □ – – –
■ – – ■ ■ ■ ■ ■ – – □ – – –
■ – – ■ ■ ■ ■ ■ – – □ – – –
■ – – ■ ■ ■ ■ ■ – – □ – – –
■ – – ■ ■ ■ ■ ■ – – □ – – –

– – ■ – – – ■ – – ■ – – – ■
– – ■ – – – ■ – – ■ – – – ■
■ – ■ ■ ■ – ■ – – ■ – – – ■
■ – ■ ■ ■ – ■ – – ■ – – – ■
■ – ■ ■ ■ – ■ – – ■ – – – ■
■ – ■ ■ ■ – ■ – – ■ – – – ■
■ – ■ ■ ■ – ■ – – ■ – – – –
– – ■ ■ – – ■ – – ■ – – – –

– – – – – – ■ – – – – – – –
– – – – – – – – – ■ – – – –

– – – – – – ■ – – – – – – –
– – – – – – – – – ■ – – – –

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ □ ■ □ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ □ ■ □ ■

– – ■ ■ – – – – – ■ ■ ■ – –
– – – ■ – – – – – ■ ■ ■ – –
From page 3/12 From From page 4/18 From page 4/52 From page 5/6
page
3/42

System overview, page 3/5


Siemens LV 10 · 10/2021 3/45
© Siemens 2021
Miniature Circuit Breakers | Accessories

Electrical accessories
Auxiliary switches (AS)
• Signals the contact position of the mounted device
• Version for the switching of small currents and voltages
according to EN 61131-2 for control of programmable control
systems (PLCs)
• Test button enables the testing of control circuits without the
need to switch the mounted device

For combining with basic units Contacts Version Mounting Article No.
Miniature Device RCCBs RCBOs Arc fault ON/OFF width
3 circuit
breakers
protection
switches
detection
devices
switches (1 MW =
18 mm)
Auxiliary switches (AS)
5SL, 5SY, 5SY17 5SV 5SU1 1), 5SV6 5TL1, 5TE8 1 NO + 1 NC Standard 0.5 MW 5ST3010
5SP4 5SV1 For low power 0.5 MW 5ST3013
For low power 0.5 MW 5ST3013-0XX01
(with diode)
2 NO Standard 0.5 MW 5ST3011
For low power 0.5 MW 5ST3014
2 NC Standard 0.5 MW 5ST3012
For low power 0.5 MW 5ST3015
1 CO Standard 0.5 MW 5ST3016
Auxiliary switches (AS) with TEST button
5SL, 5SY, 5SY17 5SV 5SU1 1), 5SV6 5TL1, 5TE8 1 NO + 1 NC Standard 0.5 MW 5ST3010-2
5SP4 5SV1 For low power 0.5 MW 5ST3013-2
2 NO Standard 0.5 MW 5ST3011-2
For low power 0.5 MW 5ST3014-2
2 NC Standard 0.5 MW 5ST3012-2
For low power 0.5 MW 5ST3015-2
Auxiliary switches (AS) acc. to UL 489
5SJ4...-.HG – – – – 1 NO + 1 NC Standard 0.5 MW 5ST3010-0HG
2 NO Standard 0.5 MW 5ST3011-0HG
2 NC Standard 0.5 MW 5ST3012-0HG
1)
5ST3805-1 handle coupler required

Quick selection guide, page 3/44


3/46 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5ST3010, 5ST3013,
5ST3011, 5ST3010-0HG, 5ST3010-2, 5ST3014, 5ST3013-2,
5ST3012, 5ST3011-0HG, 5ST3011-2, 5ST3015, 5ST3014-2,
Further technical specifications 5ST3016 5ST3012-0HG 5ST3012-2 5ST3013-0XX01 1) 5ST3015-2
Standards
Standards IEC/EN IEC/EN 62019, IEC/ – IEC/EN 62019, IEC/EN 60947-5-1
EN 60947-5-1
UL, CSA UL 1077, UL 489, – UL 1077, –
CSA C22.2 No. 235 CSA 22.2 No. 5-02 CSA C22.2 No. 235
Contacts
Minimum contact load 50 mA, 24 V 1 mA, 5 V DC 5 mA, 5 V DC 3
Maximum contact load – 100 mA, 30 V DC 50 mA, 30 V DC
Contact load acc. to IEC/EN 62019 230 V AC, AC-12 –
and IEC/EN 60947-5-1 230 V AC, AC-13 6 A/6 A –
400 V AC, AC-13 2 A/2 A –
230 V AC, AC-14 6 A/6 A –
400 V AC, AC-14 2 A/2 A –
24 V DC, DC-13 6 A/3 A –
30 V DC, DC-14 – 0.1 A
60 V DC, DC-13 3 A/1.5 A –
110 V DC, DC-13 1 A/0.75 A –
220 V DC, DC-12 –
220 V DC, DC-13 1 A/0.5 A –
Contact load acc. to UL 120 V AC – 6A –
125 V AC 3A –
240 V AC 4A –
277 V AC – 3A –
480 V AC 1,5 A –
60 V DC – 3A –
125 V DC 1,1 A 1A –
250 V DC 0,55 A –
Service life, on average, with rated load Actuations 20000 12000 20000
Safety
Short-circuit protection 5SY… 6A miniature circuit breaker or gG 6 A fuse
Connections
Conductor cross-sections 0.5 … 2.5 mm2 (AWG 22 … 14)
Terminals Max. tightening torque 0.5 Nm (4.5 lb-in)
Ambient conditions
Permissible ambient temperature –40 ... +70 °C
Permissible storage temperature –40 ... +75 °C
Resistance to climate Acc. to IEC 60068-2-30 28 cycles
Mounting position Any
Shock at 11 ms half-sine Acc. to IEC 60068-2-27 150 m/s2
Resistance to vibrations at 5 ... 150 Hz Acc. to IEC 60068-2-6 50 m/s2
1)
No approvals

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/47
© Siemens 2021
Miniature Circuit Breakers | Accessories

Electrical accessories
Fault signal contacts (FC)
• Signals automatic tripping of the protective switching device in the event
of a fault, such as an overload or a short circuit
• If the fault signal contact is activated, the contact position does not change
if the protective switching device is tripped manually
• Version with TEST and RESET buttons enable the testing of control circuits
without operation of the protective switching device
• Red RESET button in the operating handle indicates automatic tripping
of the mounted protective switching device

3 For combining with basic units Contacts Mounting width Article No.
Miniature circuit Device protection RCCBs RCBOs Arc fault (1 MW = 18 mm)
breakers switches detection devices
Fault signal contacts (FC)
5SL, 5SY, 5SP4 5SY17 5SV 5SU1 1), 5SV1 5SV6 1 NO + 1 NC 0.5 MW 5ST3020
2 NO 0.5 MW 5ST3021
2 NC 0.5 MW 5ST3022
Fault signal contacts (FC) with TEST and RESET button
5SL, 5SY, 5SP4 5SY17 5SV 5SU1 1), 5SV1 5SV6 1 NO + 1 NC 0.5 MW 5ST3020-2
2 NO 0.5 MW 5ST3021-2
2 NC 0.5 MW 5ST3022-2
Fault signal contacts (FC) acc. to UL 489
5SJ4...-.HG – – – – 1 NO + 1 NC 0.5 MW 5ST3020-0HG
2 NO 0.5 MW 5ST3021-0HG
2 NC 0.5 MW 5ST3022-0HG
1)
5ST3805-1 handle coupler required

5ST3020, 5ST3020-2, 5ST3020-0HG,


5ST3021, 5ST3021-2, 5ST3021-0HG,
Further technical specifications 5ST3022 5ST3022-2 5ST3022-0HG
Standards
Standards IEC/EN IEC/EN 62019, IEC/EN 60947-5-1
UL, CSA UL 1077, CSA C22.2 No. 235 – UL 489, CSA 22.2 No. 5-02
Contacts
Minimum contact load 50 mA, 24 V
Contact load acc. to 230 V AC, AC-13 6 A/6 A
IEC/EN 62019/IEC/EN 60947-5-1 400 V AC, AC-13 6 A/6 A
230 V AC, AC-14 2 A/2 A
400 V AC, AC-14 2 A/2 A
24 V DC, DC-13 6 A/3 A
60 V DC, DC-13 3 A/1.5 A
110 V DC, DC-13 1 A/0.75 A
220 V DC, DC-13 1 A/0.5 A
Contact load acc. to UL 120 V AC – 6A
125 V AC 3A –
240 V AC 4A –
277 V AC – 3A
480 V AC 1.5 A –
60 V DC – 3A
125 V DC 1.1 A – 1A
250 V DC 0.55 A –
Service life, on average, with rated load Actuations 20000 12000
Safety
Short-circuit protection Miniature circuit breaker or gG 6 A fuse
Connections
Conductor cross-sections 0.5 … 2.5 mm2 (AWG 22 … 14)
Terminals Max. tightening torque 0.5 Nm (4.5 lb-in)
Ambient conditions
Permissible ambient temperature –25 … +55 °C
Permissible storage temperature –40 ... +75 °C
Resistance to climate Acc. to IEC 60068-2-30 28 cycles
Mounting position Any
Shock at 11 ms half-sine Acc. to IEC 60068-2-27 150 m/s2
Resistance to vibrations at 10 ... 150 Hz Acc. to IEC 60068-2-6 50 m/s2

Quick selection guide, page 3/44


3/48 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

Auxiliary switches and fault signal contacts (AS+FC)


• Combines the function of both switches in a width of only 0.5 MW (9 mm)
• Signals the contact position of the mounted device
• Signals automatic tripping of the protective switching device in the event of a fault,
such as an overload, a short circuit or a fault current
• If the fault signal contact is activated, the contact position does not change
if the protective switching device is tripped manually

For combining with basic units Contacts Mounting width Article No.
Miniature circuit Device protection RCCBs RCBOs Arc fault (1 MW = 18 mm)
breakers switches detection devices 3
Auxiliary switches and fault signal contacts (AS+FC)
5SL, 5SY, 5SP4 5SY17 5SV 5SU1 1), 5SV1 5SV6 1 CO (AS) + 1 CO (FC) 0.5 MW 5ST3062

1)
5ST3805-1 handle coupler required

Further technical specifications 5ST3062


Standards
Standards IEC/EN IEC/EN 62019, IEC/EN 60947-5-1
UL, CSA UL 1077, CSA C22.2 No. 235
Contacts
Minimum contact load 50 mA, 24 V
Maximum contact load –
Contact load acc. to 230 V AC, AC-13 6 A/6 A
IEC/EN 62019/IEC/EN 60947-5-1 400 V AC, AC-14 2 A/2 A
Contact load acc. to 24 V DC, DC-13 3 A/3 A
IEC/EN 62019/IEC/EN 60947-5-1 60 V DC, DC-13 3 A/1 A
110 V DC, DC-13 0.5 A/0.5 A
220 V DC, DC-13 0.5 A/0.3 A
Contact load acc. to UL 125 V AC 2A
240 V AC 1.5 A
480 V AC 0.75 A
125 V DC 0.5 A
250 V DC 0.3 A
Service life, on average, with rated load Actuations 20000
Safety
Short-circuit protection Miniature circuit breaker or gG 6 A fuse
Connections
Conductor cross-sections 0.5 … 2.5 mm2 (AWG 22 … 14)
Terminals Max. tightening torque 0.5 Nm (4.5 lb-in)
Ambient conditions
Permissible ambient temperature –25 … +55 °C
Permissible storage temperature –40 ... +75 °C
Resistance to climate Acc. to IEC 60068-2-30 28 cycles
Mounting position Any
Shock at 11 ms half-sine Acc. to IEC 60068-2-27 150 m/s2
Resistance to vibrations at 10 ... 150 Hz Acc. to IEC 60068-2-6 50 m/s2

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/49
© Siemens 2021
Miniature Circuit Breakers | Accessories

Electrical accessories
5ST3 COM auxiliary switches and fault signal contacts (AS+FC)
with communication and measuring function new

For combining with basic units Mounting width Article No.


Miniature circuit Device protec- RCCBs RCBOs Arc fault Communication (1 MW = 18 mm)
breakers tion switches detection devices
5ST3 COM auxiliary switches and fault signal contacts (AS+FC) with communication and measuring function
5SL, 5SY, 5SP4 5SY17 5SV 5SU1 1), 5SV1 5SV6 Radio link to 7KN 0.5 MW 5ST3062-0MC
Powercenter 1000
1)
5ST3805-1 handle coupler required

3 Note:
Please note the country-specific radio licenses of the products in SIOS:
www.siemens.com/lowvoltage/certificates

Further technical specifications 5ST3062-0MC


Standards
Standards IEC/EN; UL, CSA 60669-2-5
RED 2014/53/EU
Power supply
Power supply 24 V DC ±20%, SELV
Conductor cross-sections 0.2 … 1.5 mm²
Connection type Plug-in terminal
Safety
Pollution degree for overvoltage category 2/II
Degree of protection IP40, with front cover
Ambient conditions
Permissible ambient temperature –25 … +60 °C
Permissible storage temperature –40 … +85 °C
Humidity 93% at 40 °C
Resistance to climate Acc. to IEC 60068-2-30 28 cycles
Mounting position Any
Schock 150 m/s2
Resistance to vibrations at 10 … 150 Hz Acc. to IEC 60068-2-6 50 m/s2
Service life 10000
Communication
Interface 7KN Powercenter 1000 Radio link
Temperature Measuring accuracy of 2.5 °C with limit monitoring incl. storage
(1 hour in 1-minute intervals and 7 days in 15-minute intervals)
Operating cycle counters Mechanical operation with limit monitoring
Trip counter Trip of the mounted circuit protection device with limit monitoring

Quick selection guide, page 3/44


3/50 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

7KN Powercenter 1000 data transceiver

SENTRON SENTRON
• Wireless radio transmission of 3
powerconfig powerconfig mobile measured values and data to the
or other 7KN Powercenter 1000 data
Software transceiver
Solutions
• Commissioning, parameter assign-
Modbus TCP ment, firmware updates and
further processing of the data via
the 7KN Powercenter 1000 data
transceiver

7KN Powercenter 1000 Article No.


I201_20143

7KN1110-0MC00
7KN Powercenter 1000
See page 10/17
You will find further information under:
Installation manual – Circuit
protection devices with
... ... ... ... communication and measuring
function (109791805)
System manual – Circuit protection
5SL6 COM 5ST3 COM 5SV6 COM 3NA COM
MCB AS+FC AFDD Fuse devices with communication and
max. 24 measuring function (109791806)
Wireless Protocol

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/51
© Siemens 2021
Miniature Circuit Breakers | Accessories

Electrical accessories
Shunt trips (ST)
• For remote-controlled tripping of the mounted device

For combining with basic units Rated operational voltage Ue Mounting width Article No.
Miniature circuit breakers RCCBs RCBOs (1 MW = 18 mm)
Shunt trips (ST)
5SL4, 5SY, 5SP 5SV 5SU1 1) 110 … 415 V AC, 110 … 220 V DC 1 MW 5ST3030
24 ... 48 V AC/DC 1 MW 5ST3031
12 V DC new 1 MW 5ST3031-0XX01
Shunt trips (ST) acc. to UL 489
3 5SJ4...-.HG – – 110 … 415 V AC, 110 … 220 V DC 1 MW 5ST3030-0HG
24 ... 60 V AC/DC 1 MW 5ST3031-0HG
1)
5ST3805-1 handle coupler required

Further technical specifications 5ST3030 5ST3031 5ST3031-0XX01 5ST3030-0HG 5ST3031-0HG


Standards
Standards IEC/EN EN 60947-1 IEC/EN 60947-1
UL, CSA – UL 489, UL-File E321559,
CSA 22.2 No. 5-02
Supply
Primary operating range 0.7 … 1.1 × Un
Rated frequency fn 50 … 60 Hz – 50 … 60 Hz
Contacts
Minimum contact load 50 mA, 24 V 1 mA, 5 V 50 mA, 24 V
Tripping operations Max. 2000
Service life, on average, Actuations 20000 12000
with rated load
Safety
Short-circuit protection Miniature circuit breaker B/C 6 A or fuse gG 6 A
Connections
Conductor cross-sections 0.5 … 2.5 mm2 (AWG 22 … 14)
Terminals Max. tightening torque 0.8 Nm (6.8 lb-in)
Ambient conditions
Permissible ambient temperature –25 … +55 °C –40 ... +70 °C –25 … +55 °C
Permissible storage temperature –40 ... +75 °C
Resistance to climate Acc. to IEC 60068-2-30 28 cycles
Mounting position Any
Shock at 11 ms half-sine Acc. to IEC 60068-2-27 150 m/s2
Resistance to vibrations Acc. to IEC 60068-2-6 50 m/s2
at 10 ... 150 Hz

Quick selection guide, page 3/44


3/52 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

Undervoltage releases (UR)


• Integrated, for example, in EMERGENCY-STOP loops
• Ensure that the mounted device trips in the event of an emergency, guaranteeing
disconnection of the control circuit according to EN 60204
• Trip the mounted device if the voltage is interrupted or too low, i.e. prevents
activation of the mounted device

For combining with basic units Rated operational voltage Ue Mounting width Article No.
Miniature circuit breakers RCCBs RCBOs (1 MW = 18 mm)
With integrated auxiliary switch
5SL4, 5SY, 5SP4 5SV 5SU1 1) 230 V AC 1 MW 5ST3040 3
110 V DC 1 MW 5ST3041
24 V DC 1 MW 5ST3042
Without integrated auxiliary switch
5SL4, 5SY, 5SP4 5SV 5SU1 1) 230 V AC 1 MW 5ST3043
110 V DC 1 MW 5ST3044
24 V DC 1 MW 5ST3045
1)
5ST3805-1 handle coupler required

Further technical specifications 5ST304.


Standards
Standards IEC/EN EN 60947-1
Supply
Primary operating range 0.85 … 1.1 × Un
Rated frequency fn 50/60 Hz
Contacts
Minimum contact load 50 mA, 24 V
Tripping operations Max. 2000
Service life, on average, with rated load Actuations 20000
Safety
Short-circuit protection Miniature circuit breaker B/C 6 A or fuse gG 6 A
Connections
Conductor cross-sections 0.5 … 2.5 mm2 (AWG 22 … 14)
Terminals Max. tightening torque 0.8 Nm (6.8 lb-in)
Ambient conditions
Permissible ambient temperature –25 … +55 °C
Permissible storage temperature –40 ... +75 °C
Resistance to climate Acc. to IEC 60068-2-30 28 cycles
Mounting position Any
Shock at 11 ms half-sine Acc. to IEC 60068-2-27 150 m/s2
Resistance to vibrations at 10 ... 150 Hz Acc. to IEC 60068-2-6 50 m/s2

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/53
© Siemens 2021
Miniature Circuit Breakers | Accessories

Electrical accessories
5ST3 remote controlled mechanisms (RC mech.)
• For locations that are spread out over a wide area or not permanently attended
• Permits direct and immediate access to the installation even if it is remote or in a location
that is hard to access
• Permits fast reconnection after a fault
• Version with ARD with automatic restart
• Versions with ARD and Power with integrated auxiliary switches and fault signal contacts

Type of remote Display Ambient Vibration and shock Rated operational voltage Ue Mounting width Article No.
operating mechanism temperature requirements (1 MW = 18 mm)
3 Basic – –25 °C … +45 °C – 12 ... 30 V AC, 12 ... 48 V DC 1.5 MW 5ST3053
177 … 270 V AC 2 MW 5ST3054
Power LED –25 °C … +45 °C – 12 ... 30 V AC, 12 ... 48 V DC 2 MW 5ST3055
177 … 270 V AC 2 MW 5ST3056
Power with ARD LED –25 °C … +45 °C – 12 ... 30 V AC, 12 ... 48 V DC 2 MW 5ST3057
177 … 270 V AC 2 MW 5ST3058
Power with extended LED –40 °C … +70 °C Acc. to EN 61373/ 12 ... 30 V AC, 12 ... 48 V DC 2 MW 5ST3070
function EN 50155 "1B" 170 ... 277 V AC, 77 ... 286 V DC 2 MW 5ST3071 new

Further technical specifications 5ST3053 5ST3054 5ST3055 5ST3056 5ST3057 5ST3058 5ST3070 5ST3071
Standards
Standards EN 50557 (VDE 0640-20)
Supply
Rated frequency fn 50 ... 60 Hz
Rated power dissipation in standby ≤1 VA
Contacts
Service life, on average, Actuations 10000
with rated load
Number of remote switching 2
operations per minute
Number of automatic reclose attempts – 3 –
Cable length in the control circuit ≤1500 m ≤1500 m (DC)/
≤200 m (AC)
Sliding selector with locking device – ■
Integrated auxiliary switches – 1W (1CO);
2 A; 250 V
Integrated fault signal contact – 1W (1CO);
2 A; 250 V
Connections
Conductor cross-sections 0.5 … 1.5 mm2 (AWG 14 … 30)
Terminal tightening torque 0.2 … 0.25 Nm (2.0 lb-in)
Ambient conditions
Permissible storage temperature –40 … +55 °C –40 … +70 °C
Degree of protection IP20
Pollution degree for overvoltage category 3/II

Suitable adapters for combination with basic units

Basic units Mounting width Article No.


1–2 MW 3–4 MW 3–6 MW
5SY4/5/6/7/8 ■ – – 5ST3820-1
– ■ – 5ST3820-2
5SL3/4/6 ■ – – 5ST3820-6
– ■ – 5ST3820-7
5SL60/5SY17 ■ – – 5ST3820-6
5SP4 ■ – – 5ST3820-1
– – ■ 5ST3820-2

Quick selection guide, page 3/44


3/54 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5SM6 arc fault detection units (AFDD)


• Detects arcing faults
• Offers extremely effective protection against fires
started by electrical faults
• Ensures adequate fire protection even in applications
without residual current protective device

For combining with basic units Rated current Ie Mounting width Article No.
Width of basic unit Miniature circuit breakers RCBOs (1 MW = 18 mm)
1 MW 5SL60 1P + N (no KL types) 5SV1 Up to 16 A 1 MW 5SM6011-2
Up to 40 A 1 MW 5SM6014-2 3
2 MW 5SY , 5SL4 (1P+N devices only)
1)
5SU1.5 Up to 16 A 1 MW 5SM6021-2
Up to 40 A 1 MW 5SM6024-2
1)
Not suitable for use with 5SY5, 5SY8

Further technical specifications 5SM6


Standards
Standards IEC/EN 62606
Supply
Rated voltage Un 230 V
Rated current In Up to 16/40 A
Rated frequency 50 Hz
Power loss 0.6 W
Contacts
Number of poles 2-pole
Service life Average number of operating cycles >10000
Safety
Touch protection Acc. to EN 50274 (VDE 0660-514) Finger and back-of-hand safe
Degree of protection Acc. to EN 60529 (VDE 0470-1) IP20, with connected conductors
Overvoltage category III
Tripping in the event of overvoltage >275 V
Connections
Terminal/conductor cross-sections Solid and stranded 0.75 … 16 mm2
Finely stranded with end sleeve 0.75 … 10 mm2
Terminal tightening torque 2.0 ... 2.5 Nm
Mains connection Bottom
Ambient conditions
Permissible ambient temperature –25 … +40 °C
Permissible storage temperature –40 ... +75 °C
Resistance to climate at 95% relative air humidity Acc. to IEC 60068-2-30 28 cycles, 55 °C
Pollution degree 2
CFC and silicone-free Yes
Mounting position Any

Suitable busbars, page 3/58 onwards


Suitable terminals and end caps, page 3/74 onwards

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/55
© Siemens 2021
Miniature Circuit Breakers | Accessories

Mechanical accessories

Mechanical rotary operating mechanisms complete with handle


• For 5SY, 5SP4, 5SL (but not for 5SL.0 1P + N in 1TE), 5TL1, 5TE2, 5TE8, 5SU1
Types Article No.
Handle black 5ST3060
Handle red / yellow 5ST3061

Terminal cover
• For miniature circuit breakers, but not for 5SL60..
• For additional covering of the screw openings per pole
3 • Lockable
• In the case of 5SY, also prevents removal of device from the standard mounting rail
Article No.
5ST3800
Handle locking devices
• To prevent undesired mechanical ON/OFF switching
• Sealable and lockable
For miniature circuit breakers For padlocks with Article No.
5SP4, 5SY Max. 3 mm shackle 5ST3801

5SL, 5TL1 3 … 6 mm shackle 5ST3806

Padlocks
• For 5ST3801 and 5ST3806 handle locking devices and remote operating mechanisms
5ST3054 … 58, 5ST3070
Article No.
5ST3802

Locking devices
• Comprising 5ST3801 or 5ST3806 handle locking device and 5ST3802 padlock
For miniature circuit breakers Comprising Article No.
5SP4 and 5SY 5ST3801 handle locking device, 5ST3803
5ST3802 padlock
5SL, 5SV, 5TL1 5ST3806 handle locking device, 5ST3807
5ST3802 padlock
Spacers
• Can be placed on either side of the standard mounting rail. Two spacers allow for convenient cable routing
Mounting width Article No.
0.5 MW 5TG8240

System overview, page 3/5


3/56 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

Device labels
• Adhesive
• For modular installation devices, e.g. 5SY, 5SL, 5TL1
Types Article No.
15 x 6 mm, white (WIN 098) 8WH8210-0AA35
15 x 6 mm, yellow (WIN 099) 8WH8210-0AA36

Terminal covers, gray


• For surface mounting, degree of protection IP40
• Sealable
• Can be used with 35 mm mounting rail
3
For widths up to Article No.
2.5 MW 5SW3004
4.5 MW 5SW3005
Wall enclosures, gray
• For flush mounting, degree of protection IP40
• Can be used with 35 mm mounting rail
For widths up to Article No.
2.5 MW 5SW3006
4.5 MW 5SW3007

Molded-plastic enclosures, gray


• For surface mounting, degree of protection IP54
• Sealable
• Can be used with 35 mm mounting rail
• With transparent hinged lid
For widths up to Article No.
4.5 MW 5SW1200

Covers
• Can be assembled as mini distribution board
• Suitable for all devices
• Cover parts prepared for rail mounting of conventional label caps
Comprising Article No.
End plate 5ST2134
Angled profile 5ST2135
Alternatively flat profile 5ST2136
Holders for front panel installation
• Universal use for devices from 1 to 6 MW
Cutout height Cutout width Article No.
45+0.5 mm 23, 41, 59, 77, 95 or 113 mm 7LF9006

Intermediate frames
• For 70 mm devices in 55 mm ALPHA SIMBOX small distribution boards
Types Article No.
1-tier 8GB4561
2-tier 8GB4562
3-tier 8GB4563
4-tier 8GB4564

System overview, page 3/5


Siemens LV 10 · 10/2021 3/57
© Siemens 2021
Miniature Circuit Breakers | Accessories

Standard busbars
General information

Infeed
At the start or end of the busbar Along the busbar or midpoint infeed
3 2 1 1 2 3

3
I201_13755

S I201_13754a

S1 S2

Maximum busbar current IS/phase Maximum busbar current IS/phase


• Cross-section 10 mm2: 63 A • Cross-section 10 mm2: 100 A
• Cross-section 16 mm2: 80 A • Cross-section 16 mm2: 130 A

Quick selection guide, page 3/44


3/58 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

Fixed length, cannot be cut


For miniature circuit breakers (MCBs)
Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 10 mm2 16 mm2
1-phase Article No. Article No.
1 For 2 MCBs 1P 2 MW 33 mm 5ST3600 5ST3630

L1 L1
14

3,4

1 For 6 MCBs 1P 6 MW 105 mm 5ST3601 5ST3631 3


For 12 MCBs 1P 12 MW 212 mm 5ST3602 5ST3632
L1 L1
14

3,4

2-phase/1-phase + N Article No. Article No.


1 1 For 2 MCBs (2P/1P+N) 4 MW 76 mm 5ST3606 5ST3636
For 3 MCBs (2P/1P+N) 6 MW 105 mm 5ST3607 5ST3637
For 6 MCBs (2P/1P+N) 12 MW 210 mm 5ST3608 5ST3638
15,2

L1 L2/N L1 L2
19

6,6 7,3

∅ 10 mm2 ∅ 16 mm2
3-phase Article No. Article No.
1 1 1 1 For 2 MCBs 3P 6 MW 102 mm 5ST3613 5ST3643
For 3 MCBs 3P 9 MW 157.5 mm 5ST3614 5ST3644
L3L1 L2 L3 For 4 MCBs 3P 12 MW 210 mm 5ST3615 5ST3645
15,2

L1 L2
19

For 14 MCBs 1P new 14 MW 250 mm 5ST3613-4 –


9,2 10,3
Combi pack: 5ST3656 –
∅ 10 mm 2
∅ 16 mm 2
20× 5ST3613 + 10× 5ST3614 +
50× 5ST3615 + 50× 5ST3655
Combi pack: – 5ST3657
20× 5ST3643 + 10× 5ST3644 +
50× 5ST3645 + 50× 5ST3655
4-phase/3-phase + N Article No. Article No.
1 1 1 1 1 1 For 2 MCBs (4P/3P+N) 8 MW 138 mm/ 5ST3621 5ST3651
140 mm
For 3 MCBs (4P/3P+N) 12 MW 210 mm 5ST3622 5ST3652
15,2

L1 L2 L3L1 N L2 L3 N
19

11,8 13,3

∅ 10 mm2 ∅ 16 mm2
1 1 11 11 11 1 1 For 6 MCBs (1P+N) 12 MW 210 mm 5ST3623 5ST3653
For 7 MCBs (1P+N) new 14 MW 248 mm 5ST3623-4 –
15,2

L1 N L2L1 N N L3L2 N N L3 N
19

11,8 13,3

∅ 10 mm2 ∅ 16 mm2

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/59
© Siemens 2021
Miniature Circuit Breakers | Accessories

Standard busbars
Fixed length, cannot be cut
For MCBs equipped with auxiliary switch (AS) or fault signal contact (FC)
Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 10 mm2 16 mm2
1-phase Article No. Article No.
1,5 For 2 MCBs 1P 2 MW 40 mm 5ST3603 5ST3633
9 mm

L1 AS L1
14

FC

3
3,4

1,5 For 6 MCBs 1P 6 MW 158 mm 5ST3604 5ST3634


For 9 MCBs 1P 9 MW 237 mm 5ST3605 5ST3635
9 mm

L1 AS L1
14

FC

3,4

2-phase/1-phase + N Article No. Article No.


1 1,5 For 2 MCBs 4 MW 76 mm – 5ST3640
(2P/1P+N)
9 mm

For 3 MCBs 6 MW 121 mm – 5ST3641


L1 L2/N AS L1 (2P/1P+N)
19

FC
For 5 MCBs 10 MW 210 mm – 5ST3642
7,3
(2P/1P+N)
3-phase Article No. Article No.
1 1 1
1,5 1 1,5 For 2 MCBs 3P 6 MW 115 mm 5ST3616 5ST3646
For 4 MCBs 3P 12 MW 237 mm 5ST3617 5ST3647
9 mm
9 mm

AS
L3L1 AS L2L1 L3 FC L1
15,2

L1 L2
19

FC

9,2 10,3

∅ 10 mm2 ∅ 16 mm2
1,5 1,5 1,5 1,5 1,5 1,5 For 6 MCBs 1P 9 MW 156 mm/ 5ST3618 5ST3648
158 mm
9 mm
9 mm

9 mm
9 mm
9 mm

9 mm

For 9 MCBs 1P 12 MW 227 mm 5ST3620 5ST3650


AS AS
L1 AS L2 L1 AS AS
L3 L2
AS
L1 L3 FC L1
15,2

19

FC FC FC FC FC

9,2 10,3

∅ 10 mm2 ∅ 16 mm2

Accessories
Terminals for 5ST36 and 5ST37 Article No. Terminals for infeed at side Article No.
For conductors up to Cable entry on the left 5ST3768-4 For conductors up to Short 5ST3768
25 mm2 Cable entry in the center 5ST3768-3 25 mm2
Cable entry on the right 5ST3768-5 Short, IP20 5ST3771-2
For conductors up to Cable entry on the left 5ST3760-4 Touch protection Article No.
50 mm2 Cable entry in the center 5ST3760-3 For free connections, yellow (RAL 1004) 5× 1 pin 5ST3655
Cable entry on the right 5ST3760-5

Quick selection guide, page 3/44


3/60 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

For MCBs with RCCB


Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 10 mm2 16 mm2
3-phase Article No. Article No.
1 1 12 1 1 21 11 11 11 11 11 1 1 For 8 MCBs 1P 12 MW 210 mm 5ST3624 5ST3654
with 1 RCCB 3P+N,
72 mm

72 mm

N right

15,2
L1 L2 L3L1 NL2 L1L3 L2N L3L1 L1L2 L2L3 L3L1 L1L2 L2L3 L1 L2

19
3
9,2 10,3

∅ 10 mm2 ∅ 16 mm2
1 1 2 1 1 1 1 1 1 1 1 1 For 10 MCBs 1P 14 MW 249 mm 5ST3624-4 –
with 1 RCCB 3P+N new
72 mm

or for 1 RCCB 3P+N,


,B
1 MCBs 3P and 7

15,2
L1 L2 L3 N L1 L2 L3 L1 L2 L3 L1 L2 L3 L1
MCBs 1P
8,6

1 1 2 1 1 1 1 1 For 6 MCBs 1P with 10 MW 176 mm 5ST3624-1 –


1 RCCB 3P+N or new
72 mm

for 1 RCCB 3P+N,


,B

1 MCB 3P and
15,2

L1 L2 L3 N L1 L2 L3 L1 L2 L3
3 MCBs 1P
8,6

1 1 11 11 11 11 11 11 11 11 1 1 For 8 MCBs 1P with 11 MW 192 mm 5ST3667 5ST3668


1 RCCB 3P+N, N left
72 mm
72 mm

N L1 N
L2 L1
L3 L2
L1 L3
L2 L1
L3 L2
L1 L3
L2 L1
L3 L2
L1 L3
L2 L1 L2
15,2

19

9,2 10,3

∅ 10 mm2 ∅ 16 mm2
4-phase/3-phase + N Article No. Article No.
1 1 1 1 1 1 1 1 1 1 1 1 1 For 1 RCCB 3P+N, 14 MW 248 mm 5ST3724-4 –
1 MCBs 3P+N and new
6 MCBs 1P
,B

15,2

L1 L2 L3 N L1 L2 L3 N L1 L2 L3 L1 L2 L3

10,7

1 1 1 1 1 1 1 1 1 1 1 1 1 For 1 RCCB 3P+N, 14 MW 248 mm 5ST3725-4 –


1 MCBs 3P+N and new
3 MCBs 1P+N
,B

15,2

L1 L2 L3 N L1 L2 L3 N L1 N L2 N L3 N

10,7

1 1 1 1 1 1 1 1 1 1 1 1 For 1 RCCB 3P+N, 13 MW 230 mm 5ST3725-3 –


1 MCBs 3P and new
3 MCBs 1P+N
,B

15,2

L1 L2 L3 N L1 L2 L3 L1 N L2 N L3 N

10,7

1 1 1 1 1 1 1 1 1 1 1 1 1 For 1 RCCB 3P+N 14 MW 248 mm 5ST3625-4 –


and 5 MCBs 1P+N new
,B

15,2

L1 L2 L3 N L1 N L2 N L3 N L1 N L2 N

10,7

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/61
© Siemens 2021
Miniature Circuit Breakers | Accessories

Standard busbars
Can be cut
For miniature circuit breakers (MCBs)
Pin spacing in MW (1 MW = 18 mm) Application No. of Length End caps Color Conductor cross-section
MW incl. 10 mm2 16 mm2
1-phase, straight Article No. Article No.
1 For MCBs 1P+N 12 MW 216 mm ■ Gray 5ST3762 –
compact Blue 5ST3687-0 –
L1 L1 56 MW 1016 mm – Gray 5ST3764 –
10

5,6 Blue 5ST3787-0 –

3 1-phase, angled 45° Article No. Article No.


1 1 For MCBs 1P+N 12 MW 216 mm ■ Blue 5ST3763 –
compact 56 MW 1016 mm – Blue 5ST3765 –
10

5,6

1-phase, angled 90° Article No. Article No.


1 For MCBs 1P 12 MW 214 mm ■ 5ST3730 5ST3700
3,5

56 MW 1016 mm – 5ST3731 5ST3701


L1 L1 13

2-phase/1-phase + N Article No. Article No.


1 For 2MW devices 12 MW 214 mm ■ 5ST3734 5ST3704
(2P/1P+N) 56 MW 1016 mm – 5ST3735 5ST3705
L1 L2/N
15

18

3-phase Article No. Article No.


1 1 For MCBs 3P 12 MW 214 mm ■ 5ST3738 5ST3708
56 MW 1016 mm – 5ST3740 5ST3710
L1 L2 L3
15

18

4-phase/3-phase + N Article No. Article No.


1 1 1 For MCBs 4P or 12 MW 214 mm ■ 5ST3745 5ST3715
3P+N 56 MW 1016 mm – 5ST3746 5ST3716
L1 L2 L3 N
18

20

1 1 1 1 1 1 1 1 1 1 1 1 For RCCB/MCBs or 56 MW 1000 mm – 5ST3770-2 5ST3770-3


MCBs 1P+N
17,3
17,3

L1
L1 N
N L2 L1 N N
N N L1 L3 L2 N N L3
L2 N N L3 N N L1 L3
L2 L1 N N N
N L1
L1
19,7 21,4

∅ 10 mm2 ∅ 16 mm2

Accessories
Terminals for 5ST36 and 5ST37 Article No. End caps Article No.
For conductors up to Cable entry on the left 5ST3768-4 For 1-phase busbars (MCB 1P+N compact) Gray 5ST3766
25 mm2 Cable entry in the center 5ST3768-3 Blue 5ST3767
Cable entry on the right 5ST3768-5 White 5ST3748
For conductors up to Cable entry on the left 5ST3760-4 For 2-phase busbars 5ST3750
50 mm2 Cable entry in the center 5ST3760-3 Touch protection Article No.
Cable entry on the right 5ST3760-5 For free connections, yellow (RAL 1004) 5× 1 pin 5ST3655
Terminals for Infeed at side Article No.
For conductors up to Short 5ST3768
25 mm2 Short, IP20 5ST3771-2

Quick selection guide, page 3/44


3/62 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

For MCBs equipped with auxiliary switch (AS) or fault signal contact (FC)
Pin spacing in MW Application No. of Length End caps Conductor cross-section
(1 MW = 18 mm) MW incl. 10 mm2 16 mm2
1-phase, angled 90° Article No. Article No.
1,5 For MCBs 1P 12 MW 214 mm ■ 5ST3732 5ST3702
56 MW 1016 mm – 5ST3733 5ST3703
9 mm

3,5

L1 AS L1 13
FC

2-phase/1-phase + N Article No. Article No. 3


1 1,5 For 2 MW devices 12 MW 214 mm ■ 5ST3736 5ST3706
(2P/1P+N) 56 MW 1016 mm – 5ST3737 5ST3707
9 mm

L1 L2/N AS L1
15

FC

18

3-phase Article No. Article No.


1 1 1,5 For MCBs 3P 12 MW 214 mm ■ 5ST3741 5ST3711
56 MW 1016 mm – 5ST3742 5ST3712
9 mm

L1 L2 L3 AS L1
15

FC

18

1,5 1,5 1,5 For MCBs 1P 12 MW 214 mm ■ 5ST3743 5ST3713


56 MW 1016 mm – 5ST3744 5ST3714
9 mm
9 mm

9 mm

L1 AS L2 AS L3 AS L1
15

FC FC FC

18

4-phase/3-phase + N Article No. Article No.


1 1,5 1 1,5 1 For MCBs 1P+N 56 MW 1016 mm – 5ST3746-2 –
9 mm

9 mm

L1 N AS L2 N AS L3 N
17

FC FC

20

For MCBs equipped with undervoltage release (UR) or shunt trips (ST)
Pin spacing in MW Application No. of Length End caps Conductor cross-section
(1 MW = 18 mm) MW incl.
10 mm2 16 mm2
2-phase Article No. Article No.
2 2 For MCBs 1P 56 MW 1016 mm – 5ST3735-2 –
with UR/ ST
18 mm

18 mm

L1 UR L2 UR L1
17

ST ST

14

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/63
© Siemens 2021
Miniature Circuit Breakers | Accessories

Standard busbars
Can be cut
For MCBs with line-side RCCB or RCCBs equipped with AS/FC devices
Pin spacing in MW Application No. of Length End caps Conductor cross-section
(1 MW = 18 mm) MW incl. 10 mm2 16 mm2
4-phase/3-phase + N Article No. Article No.
1 1,5 1 1,5 1 For RCCB / MCBs 56 MW 1016 mm – 5ST3746-2 –
9 mm

9 mm

L1 N AS L2 N AS L3 N
17

FC FC

3 1 1 1 1 1
20

1 For 6 MCBs 1P+N 16 MW 292 mm ■ 5ST3770-4 5ST3770-5


with 1 RCCB 3P+N,
N right
18,3

L1 L2 L3 N L2 N L3 N

22,1

Accessories
Terminals for 5ST36 and 5ST37 Article No. End caps Article No.
For conductors up to Cable entry on the left 5ST3768-4 For 3-phase busbars 5ST3750
25 mm2 Cable entry in the center 5ST3768-3 For 4-phase busbars 5ST3718
Cable entry on the right 5ST3768-5 Touch protection Article No.
For conductors up to Cable entry on the left 5ST3760-4 For free connections, yellow (RAL 1004) 5× 1 pin 5ST3655
50 mm2 Cable entry in the center 5ST3760-3
Cable entry on the right 5ST3760-5

Quick selection guide, page 3/44


3/64 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5ST37 acc. to UL 508, can be cut


For miniature circuit breakers (MCBs)
Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 18 mm2 25 mm2
1-phase Article No. Article No.
1 For MCBs 1P 56 MW 1000 mm 5ST3701-0HG –
or fuse holders 10 x 38 mm/class CC
5

L1 L1 15

1,5 For MCBs 1P 56 MW 1000 mm – 5ST3701-2HG


or fuse holders 14 x 51 mm 3
5

L1 L1 15

2-phase Article No. Article No.


1 For MCBs 2P 56 MW 1000 mm 5ST3705-0HG –
or fuse holders 10 x 38 mm/class CC
L1 L2
23

21

1,5 For MCBs 2P 56 MW 1000 mm – 5ST3705-2HG


or fuse holders 14 x 51 mm
L1 L2
23

21

3-phase Article No. Article No.


1 1 For MCBs 3P 56 MW 1000 mm 5ST3710-0HG –
or fuse holders 10 x 38 mm/class CC
L1 L2 L3
23

21

1,5 1,5 For MCBs 3P 56 MW 1000 mm – 5ST3710-2HG


or fuse holders 14 x 51 mm
L1 L2 L3
23

21

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/65
© Siemens 2021
Miniature Circuit Breakers | Accessories

Standard busbars
5ST37 acc. to UL 508, can be cut
For MCBs equipped with auxiliary switch (AS) or fault signal contact (FC)
Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 18 mm2 25 mm2
1-phase Article No. Article No.
1,5 For MCBs 1P 56 MW 1000 mm 5ST3703-0HG –
9 mm

L1 AS L1 15
FC

3 2-phase Article No. Article No.


1 1,5 For MCBs 2P 56 MW 1000 mm 5ST3707-0HG –
9 mm

L1 L2 AS L1
23

FC

21

3-phase Article No. Article No.


1 1 1,5 For MCBs 3P 56 MW 1000 mm 5ST3712-0HG –
9 mm

L1 L2 L3 AS L1
23

FC

21

1,5 1,5 1,5 For MCBs 1P 56 MW 1000 mm 5ST3714-0HG –


9 mm
9 mm

9 mm

L1 AS L2 AS L3 AS L1
23

FC FC FC

21

Accessories
Terminals according to UL 489 Article No. Touch protection according to UL 508 Article No.
For infeed at the device 35 mm2 5ST3770-0HG For open terminals, yellow 5× 1 pin 5ST3655-0HG
For infeed at the busbar 50 mm2 5ST3770-1HG
End caps according to UL 508 Article No.
For 1-phase busbars 5ST3748-0HG
For 2 and 3-phase busbars 5ST3750-0HG

Quick selection guide, page 3/44


3/66 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5ST3.. acc. to UL 489 specially for 5SJ4... -.HG..


Fixed length, cannot be cut, for miniature circuit breakers (MCBs) 1)
Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 16 mm2
1-phase Article No.
L1 L1 For 6 MCBs 1P 6 MW 100 mm 5ST3663-0HG
For 12 MCBs 1P 12 MW 205 mm 5ST3663-1HG
For 18 MCBs 1P 18 MW 310 mm 5ST3663-2HG
1 15

2-phase Article No.


L1 L2 For 3 MCBs 2P 6 MW 100 mm 5ST3664-0HG 3
For 6 MCBs 2P 12 MW 205 mm 5ST3664-1HG
For 9 MCBs 2P 18 MW 310 mm 5ST3664-2HG
1 15

3-phase Article No.


L1 L2 L3 For 2 MCBs 3P 6 MW 100 mm 5ST3665-0HG
For 4 MCBs 3P 12 MW 205 mm 5ST3665-1HG
For 6 MCBs 3P 18 MW 310 mm 5ST3665-2HG
1 1 15

1)
All unassigned pins of the busbars that cannot be cut must be covered with 5ST3666-1HG touch protection covers.

Can be cut, for MCBs


Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 18 mm2
1-phase Article No.
L1 L1 For MCBs 1P 56 MW 1016 mm 5ST3701-3HG

1 19,3

2-phase Article No.


L1 L2 For MCBs 2P 56 MW 1016 mm 5ST3705-3HG

1 19,3

3-phase Article No.


L1 L2 L3 For MCBs 3P 56 MW 1016 mm 5ST3710-3HG

1 1 19,3

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/67
© Siemens 2021
Miniature Circuit Breakers | Accessories

Standard busbars
5ST3.. according to UL 489 speziell For 5SJ4... -.HG..
Can be cut, for MCBs equipped with auxiliary switch (AS) or fault signal contact (FC)
Pin spacing in MW Application No. of MW Length Conductor cross-section
(1 MW = 18 mm) 18 mm2
1-phase Article No.
L1 AS L1 For MCBs 1P 56 MW 1016 mm 5ST3703-3HG
FC
9 mm

19,3
1,5

3 2-phase Article No.


L1 L2 AS L1 For MCBs 2P 56 MW 1016 mm 5ST3707-3HG
FC
9 mm

19,3
1 1,5

3-phase Article No.


L1 L2 L3 AS L1 For MCBs 3P 56 MW 1016 mm 5ST3712-3HG
FC
9 mm

19,3
1 1 1,5

L1 AS L2 AS L3 AS L1 For MCBs 1P 56 MW 1016 mm 5ST3714-3HG


FC FC FC
9 mm
9 mm

9 mm

19,3
1,5 1,5 1,5

Accessories
Terminals according to UL 489 Article No. Touch protection acc. to UL 489 Article No.
For infeed at the 5SJ4... -.HG.. miniature 16 mm2 5ST3666-0HG For open terminals, yellow For 5ST37..-.HG busbars that 5ST3666-1HG
circuit breaker 18 mm2 5ST3770-3HG 3× 1 pin cannot be cut
For infeed at the busbar 16 mm2 5ST3666-2HG For 5ST37..-3HG busbars that 5ST3655-3HG
can be cut
End caps acc. to UL 489 Article No.
For 1, 2 and 3-phase busbars 5ST3750-3HG

Quick selection guide, page 3/44


3/68 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

Compact busbars
General information

Infeed
At the start or end of the busbar Along the busbar or midpoint infeed
3 2 1 1 2 3

3
I201_13755

S I201_13754a

S1 S2

Maximum busbar current IS/phase Maximum busbar current IS/phase


• Cross-section 10 mm2: 63 A • Cross-section 10 mm2: 100 A
• Cross-section 16 mm2: 80 A • Cross-section 16 mm2: 130 A

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/69
© Siemens 2021
Miniature Circuit Breakers | Accessories

Compact busbars
5ST36, fixed length, cannot be cut
Pin spacing in MW Application No. of Length End caps Conductor cross-
(1 MW = 18 mm) MW incl. section
10 mm2
2-phase/1-phase + N, for infeed via RCCB Article No.
1 2 2 For 1× RCCB 1P+N and 5× compact devices 12 MW 216 mm ■ 5ST3685-0
equipped with 5SM6 arc fault detection unit
AFDD

AFDD

13,7
L1 N L1 N L1 N
42,4

3 2-phase/1-phase + N Article No.


1 1 For compact devices 6 MW 113 mm ■ 5ST3674-6
9 MW 166 mm ■ 5ST3674-7
12 MW 218 mm ■ 5ST3674-0
13,7

L1 N L1 N L1 N
42,4

1 1 For 12x 5SY17 CBE 12 MW 218 mm ■ 5ST3674-1


(device protection switch)
13,7

+ AS + AS + AS
42,4

2 For 6× compact devices equipped with 11 MW 200 mm ■ 5ST3676-0


5SM6 arc fault detection unit
AFDD

AFDD

AFDD

13,7

L1 N L1 N
42,4

4-phase/3-phase + N Article No.


1 1 1 For compact devices 6 MW 113 mm ■ 5ST3673-6
9 MW 116 mm ■ 5ST3673-7
12 MW 218 mm ■ 5ST3673-0
13,7

L1 N L2 N L3 N L1 N
42,4 14 MW 254 mm ■ 5ST3673-4

2 2 For 6× compact devices equipped with 11 MW 200 mm ■ 5ST3675-0


5SM6 arc fault detection unit
AFDD

AFDD

AFDD

13,7

L1 N L2 N L3 N
42,4

Quick selection guide, page 3/44


3/70 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5ST37, can be cut


Pin spacing in MW Application No. of Length End Conductor cross-
(1 MW = 18 mm) MW caps section
incl. 10 mm2
2-phase/1-phase + N, for infeed via RCCB Article No.
1 1 1 1 For 1× RCCB 1P+N 12 MW 215 mm ■ 5ST3784-0
and 10× compact
devices
13,7
L1 N L1 N L1 N L1 N
42,4

1 1 1 1 For 1× RCCB 1P+N 12 MW 215 mm ■ 5ST3784-0KL


(RCCB N left only) 3
and 10× compact
13,7

N L1 L1 N L1 N L1 N devices
42,4

2-phase/1-phase + N Article No.


1 1 For compact 60 MW 1060 – 5ST3774-0
devices mm

L1 N L1 N L1 N
13

40,8

2 For compact 59 MW 1042 – 5ST3776-0


devices equipped mm
AFDD

AFDD

AFDD

with 5SM6 arc


fault detection
L1 N L1 N
13

unit
40,8

1,5 1,5 For compact 59.5 1055 – 5ST3778-0


devices equipped MW mm
9 mm

9 mm

9 mm

with auxiliary
switch
L1 N AS L1 N AS L1 N AS
13

40,8

2,5 For compact 58.5 1036 – 5ST3780-0


devices equipped MW mm
AFDD

AFDD

AFDD
9 mm

9 mm

with 5SM6 arc


fault detection
L1 N AS L1 N AS
13

unit and auxiliary


40,8 switch
1 2,5 For 2 MW units 54 MW 956 mm – 5ST3786-0
(MCBs or RCBOs)
AFDD

AFDD
9 mm

with mounted
5SM6 arc fault
L1 N AS L1 N
13

FC detection unit and


40,8 auxiliary switch

Accessories
Terminals for infeed at side Article No. Touch protection Article No.
For conductors up to 25 mm2 Short, IP20 5ST3771-2 For free connections, For pins L1, N 5ST3655
End caps Article No. yellow (RAL 1004) For pins L2, L3 5ST3655-0HG
2 and 4-phase busbars 5ST3788-0

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/71
© Siemens 2021
Miniature Circuit Breakers | Accessories

Compact busbars
5ST37, can be cut
Pin spacing in MW Application No. of Length End Conductor cross-
(1 MW = 18 mm) MW caps section
incl. 10 mm2
4-phase/3-phase + N, for infeed via RCCB Article No.
1 1 1 1 1 For 1× RCCB 3P+N 10 MW 181 mm ■ 5ST3783-1 new
and 6× compact
devices

13,7
L1 L2 L3 N L1 N L2 N L3 N
For 1× RCCB 3P+N 12 MW 216 mm ■ 5ST3783-0
42,4 and 8× compact
devices
3 For 1× RCCB 3P+N 14 MW 251 mm ■ 5ST3783-4 new
and 10× compact
devices
1 1 1 1 1 For 1× RCCB 3P+N 10 MW 181 mm ■ 5ST3783-1KL new
(RCCB N left only)
and 6× compact
13,7

N L1 L2 L3 L1 N L2 N L3 N devices
42,4 For 1× RCCB 3P+N 12 MW 216 mm ■ 5ST3783-0KL
(RCCB N left only)
and 8× compact
devices
1 1 1 1 1 1 1 1 1 1 1 1 For 1× RCCB 14 MW 253 mm ■ 5ST3785-4 new
3P+N,
1× MCBs 3P and
,B

13,7

L1 L2 L3 N L1 L2 L3 L1 N L2 N L3 N L1 N L2 N L3 N L1 N 7× compact
42,4 devices
1 1 1 1 1 1 1 1 1 1 1 1 1 For 1× RCCB 24 MW 430 mm ■ 5ST3790-1 new
3P+N,
2× MCBs 3P+N
,B

13,7

L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 N L2 N and 12× compact


42,4 devices
1 1 1 1 1 1 1 1 1 1 1 1 1 For 1× RCCB 57 MW 1009 mm – 5ST3790-2 new
3P+N,
2× MCBs 3P+N
,B

L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 N L2 N and 45× compact


13

40,8 devices
1 1 1 1 1 1 1 1 1 1 1 For 1× RCCB 12 MW 217 mm ■ 5ST3795-0 new
3P+N,
1x MCBs 3P+N
,B

13,7

L1 L2 L3 N L1 L2 L3 N L1 N L2 N L3 N L1 N and 4× compact
42,4 devices
1 1 1 1 1 1 1 1 1 1 1 For 1× RCCB 14 MW 253 mm ■ 5ST3795-4 new
3P+N,
1× MCBs 3P+N
,B

13,7

L1 L2 L3 N L1 L2 L3 N L1 N L2 N L3 N L1 N L2 N L3 N and 6× compact
42,4 devices

Quick selection guide, page 3/44


3/72 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

Pin spacing in MW Application No. of Length End Conductor cross-


(1 MW = 18 mm) MW caps section
incl. 10 mm2
4-phase/3-phase + N Article No.
1 1 1 For compact 60 MW 1060 mm – 5ST3773-0
devices

L1 N L2 N L3 N L1 N
13

40,8

2 2 For compact 59 MW 1042 mm – 5ST3775-0


devices equipped 3
AFDD

AFDD

AFDD

with 5SM6 arc


fault detection
L1 N L2 N L3 N
13

unit
40,8

1,5 1,5 1,5 For compact 59.5 1055 mm – 5ST3777-0


devices equipped MW
9 mm

9 mm

9 mm

with auxiliary
switch
L1 N AS L2 N AS L3 N AS L1
13

40,8

Accessories
Terminals for infeed at side Article No. Touch protection Article No.
For conductors up to 25 mm2 Short, IP20 5ST3771-2 For free connections, For pins L1, N 5ST3655
End caps Article No. yellow (RAL 1004) For pins L2, L3 5ST3655-0HG
2 and 4-phase busbars 5ST3788-0

Quick selection guide, page 3/44


Siemens LV 10 · 10/2021 3/73
© Siemens 2021
Miniature Circuit Breakers | Accessories

Accessories for busbars


General accessories

Terminals
For conductors Version Cable entry Infeed Article No.
Up to 25 mm2 Short – Side 5ST3768
Short, IP20 – Side 5ST3771-2

Up to 25 mm2 – Center – 5ST3768-3


3 Left – 5ST3768-4
Right – 5ST3768-5

Up to 30 mm2 – – Busbar 5ST3770-1HG

Up to 35 mm2 – – Device 5ST3770-0HG

Up to 35 mm2 For 5SJ4... -.HG.. – Miniature circuit breaker 5ST3666-0HG


For 5ST37..-3HG that can be cut – Miniature circuit breaker 5ST3770-3HG

Up to 50 mm2 – Center – 5ST3760-3


Left – 5ST3760-4
Right – 5ST3760-5

Up to 50 mm2 – – Busbar 5ST3666-2HG

System overview, page 3/5


3/74 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5ST36 5ST37 5ST37 (acc. to UL 508) 5ST3.. (acc. to UL 489) 5ST3 compact

■ ■
■ ■


■ 3




System overview, page 3/5


Siemens LV 10 · 10/2021 3/75
© Siemens 2021
Miniature Circuit Breakers | Accessories

Accessories for busbars


General accessories

Touch protection
Version Scope of supply Version Article No.
For free connections, 5× 1 pin – 5ST3655
yellow (RAL 1004) 5ST3655-0HG
3× 1 pin – 5ST3666-1HG
– 5ST3655-3HG
For 10 mm2 conductors 20× 5ST3613 + 10× 5ST3614 + 50× 5ST3615 + 50× 5ST3655 – 5ST3656
For 16 mm2 conductors 20× 5ST3643 + 10× 5ST3644 + 50× 5ST3645 + 50× 5ST3655 For 5ST337..-3HG 5ST3657
3 End caps
Version Color Article No.
For 1-phase busbars Gray 5ST3748
For 2 and 3-phase busbars Gray 5ST3750
For 4-phase busbars Gray 5ST3718
For 1, 2 and 3-phase busbars Gray 5ST3750-3HG
– Gray 5ST3766
– Blue 5ST3767

For 1-phase busbars Gray 5ST3748-0HG


For 2 and 3-phase busbars Gray 5ST3750-0HG

For 2 and 4-phase compact busbars Gray 5ST3788-0

System overview, page 3/5


3/76 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5ST36 5ST37 5ST37 (acc. to UL 508) 5ST3.. (acc. to UL 489) 5ST3 compact

■ ■
■ ■




3






System overview, page 3/5


Siemens LV 10 · 10/2021 3/77
© Siemens 2021
Miniature Circuit Breakers | Accessories

Accessories for busbars


General accessories

Series connectors
Conductor cross-section Length of cable Color Number of phases Article No.
10 mm2 125 mm N conductor blue 1 5ST3781-0
Cable black 1 5ST3791-0
3 5ST3793-0
150 mm N conductor blue 1 5ST3781-1
Cable black 1 5ST3791-1
3 5ST3793-1
3
16 mm2 125 mm N conductor blue 1 5ST3782-0
Cable black 1 5ST3792-0
3 5ST3794-0
150 mm N conductor blue 1 5ST3782-1
Cable black 1 5ST3792-1
3 5ST3794-1
200 mm N conductor blue 1 5ST3781-2
Cable black 1 5ST3791-2
3 5ST3793-2
3× cables black and 3 + N 5ST3793-3
1× N conductor blue

System overview, page 3/5


3/78 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

5ST36 5ST37 5ST37 (acc. to UL 508) 5ST3.. (acc. to UL 489) 5ST3 compact







3









System overview, page 3/5


Siemens LV 10 · 10/2021 3/79
© Siemens 2021
Miniature Circuit Breakers | Accessories

Distribution blocks for standard rail mounting


Acc. to IEC
Distribution blocks acc. to IEC
Number of poles Rated operational Rated current Ie Mounting width Article No.
voltage Ue
4-pole 690 V AC 80 A 5 MW 5ST2501

125 A 5.5 MW 5ST2502


3
160 A 9 MW 5ST2503

Further technical specifications 5ST2501 5ST2502 5ST2503


Standards
Standards IEC 60947-7-1
Supply
Rated operational voltage AC 690 V
Max. rated current 80 A 125 A 160 A
Conductor cross-section
Inputs per pole Solid/stranded 1× 2.5 … 16 mm2 1× 6 … 35 mm2 1× 10 … 50 mm2
Finely stranded with end sleeve 1× 1.5 … 10 mm2 1× 6 … 25 mm2 1× 10 … 35 mm2
Outputs per pole Solid/stranded 8× 1.5 … 10 mm 2
5× 1.5 … 6 mm 2
8× 2.5 … 16 mm2
2× 4 … 16 mm2 3× 10 … 35 mm2
Finely stranded with end sleeve 8× 1.5 … 10 mm2 5× 1.5 … 6 mm2 (small) 8× 1.5 … 16 mm2 (small)
2× 4 … 10 mm2 (large) 3× 10 … 25 mm2 (large)
Tightening torque
Inputs Screw terminals 13.5 lb-in (1.5 Nm) 3.5 … 5 lb-in (2 Nm)
Tools PZ2
Outputs Screw terminals Large 13.5 lb-in (1.5 Nm)
Small – 7.2 lb-in (0.8 Nm) 13.5 lb-in (1.5 Nm)
Tools Large PZ1 PZ2
Small – PZ1 PZ2
Safety
Rated peak withstand current Ipk 21.6 kA 24 kA 20 kA
Rated short-time withstand current Icw (1 s) 3 kA 4.2 kA 6.2 kA
Ambient conditions
Permissible ambient temperature –25 … +70 °C
Degree of protection Acc. to EN 60529 IP20
Approved cable Copper

System overview, page 3/5


3/80 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

According to IEC and UL


Distribution blocks acc. to IEC and UL
Number of poles Rated operational Rated current Ie Mounting width Article No.
voltage Ue
1-pole 600 V AC 80 A 1.5 MW 5ST2504
125 A 1.5 MW 5ST2505
160 A 2 MW 5ST2507
250 A 2.5 MW 5ST2508
350 A 2.5 MW 5ST2511
Connector for 5ST2505 distribution board
• Touch protection 3
• 20 mm2
• 32 mm
Version Article No.
1-phase 5ST2506
Terminal lug for ring terminal ends
Types Article No.
For 5ST2508 distribution block 5ST2510
For 5ST2511 distribution block 5ST2512

Further technical specifications 5ST2504 5ST2505 5ST2507 5ST2508 5ST2511


Standards
Standards UL 1059/UL 486E/IEC 60947-7-1
UL File No. E80027/XCFR2
C22.2 No. 158 -1987/XCFR8
Supply
Rated operational voltage UL 600 V AC
IEC 1000/1500 V AC/DC
Max. rated current UL 80 A 115 A 160 A 230 A 310 A
IEC 80 A 125 A 160 A 250 A 400 A
Conductor cross-section
Inputs per pole Solid/stranded Large 3× 2.5 … 25 mm2 10 … 35 mm2 10 … 70 mm2 35 … 120 mm2 95 … 185 mm2
AWG 3× 14 … 4 AWG 1× 8 … 2 AWG 1× 8 … 2/0 AWG 1× 2 … 4/0 AWG 1× 3/0 … 350 MCM
Small – 2.5 … 25 mm2 –
– AWG 1× 14 … 6 –
Finely stranded Large 3× 2.5 … 16 mm2 10 … 35 mm2 10 … 50 mm2 35 … 95 mm2 95 … 150 mm2
with end sleeve AWG 3× 14 … 6 AWG 1× 8 … 2 AWG 1× 8 … 1 AWG 1× 2 … 3/0 AWG 3/0 … 300 MCM
Small – 2.5 … 25 mm2 –
– AWG 1× 14 … 6 –
Outputs per pole Solid/stranded Top 2.5 … 6 mm2 2.5 … 16 mm2 2.5 … 16 mm2 2.5 … 10 mm2 2× 2.5… 35 mm2
AWG 4× 14 … 10 AWG 6× 14 … 4 AWG 6× 14 … 4 AWG 4× 16 … 8 AWG 2× 14 … 2
Center – 2.5 … 16 mm2 5× 2.5 … 16 mm2
– AWG 5 x 14 … 6
Bottom 2.5 … 6 mm2 – 2× 2.5… 35 mm2 4× 2.5 … 10 mm2
AWG 4× 14 … 10 – AWG 2 x 14 … 2 AWG 4 x 14 … 8
Finely stranded Top 2.5 … 6 mm2 2.5 … 16 mm2 2× 2.5… 25 mm2
with end sleeve AWG 4× 14 … 10 AWG 6× 14 … 6 AWG 6× 14 … 4 AWG 2× 14 … 4
Bottom 2.5 … 6 mm2 – 2× 2.5… 25 mm2 4× 2.5 … 25 mm2
AWG 4× 14 … 10 – AWG 2 x 14 … 4 AWG 5 x 14 … 4

Continued on next page

System overview, page 3/5


Siemens LV 10 · 10/2021 3/81
© Siemens 2021
Miniature Circuit Breakers | Accessories

Distribution blocks for standard rail mounting


According to IEC and UL (continued)

Further technical specifications 5ST2504 5ST2505 5ST2507 5ST2508 5ST2511


Tightening torque
Inputs Screw terminals 13.2 … 26.5 lb-in 31 … 44 lb-in 44 … 53 lb-in 170 … 186 lb-in 222 lb-in
(1.5 … 3 Nm) (3.5 … 5 Nm) (5 … 6 Nm) (19 … 21 Nm) (25 Nm)
Tools PZ2 Allen key 4 mm Allen key 5 mm Allen key 6 mm Allen key 8 mm
Outputs Screw terminals Large 13.2 … 26.5 lb-in 17.7 … 26.5 lb-in 13.2 … 26.5 lb-in 31 … 62 lb-in
(1.5 … 3 Nm) (2 … 3 Nm) (1.5 … 3 Nm) (3.5 … 7 Nm)
Small 7 … 13.2 lb-in – 18 … 27 lb-in

3 Tools Large
(0.8 … 1.5 Nm)
PZ2
(2 … 3 Nm)
Standard screwdriver
Small PZ1 PZ2 Standard screwdriver
Safety
Rated peak withstand current Ipk 2.7 kA 30 kA 51 kA
Rated short-time withstand current Icw (1 s) 1.9 kA 4.2 kA 11 kA 21 kA
Overcurrent protection class J
Short circuit RMS Sym A 100 kA
current rating
(SCCR)
Electrical isolation Creepage distances 1/2" (12.7 mm)
Clearances 3/8" (9.5 mm)
Ambient conditions
Permissible ambient temperature –25 … +70 °C
Degree of protec- Acc. to EN 60529 IP20
tion
Fire class UL 94V-0
Approved cable Copper

System overview, page 3/5


3/82 Siemens LV 10 · 10/2021
© Siemens 2021
Accessories | Miniature Circuit Breakers

SIKclip wiring system

SIKclip busbar
Length Article No.
12 MW 5ST2520
24 MW 5ST2521
36 MW 5ST2522
Connecting cables with plug
Length Conductor cross-section Color Article No.
120 mm 6 mm2 Black 5ST2523
Blue 5ST2524
10 mm2 Black 5ST2525 3
Blue 5ST2526
200 mm 6 mm2 Black 5ST2527
Blue 5ST2528
10 mm2 Black 5ST2530
Blue 5ST2531
Crimp connector
• For connection to cables 4/6 mm2
Article No.
5ST2532

Mounting brackets
• For mounting on the rear of the standard mounting rail (pair)
Article No.
5ST2533

Further technical specifications 5ST25..


Standards
Test specifications EN 60947-1, EN 61439-1
Rated values
Rated operational voltage Un 400 V AC
Max. rated current In 250 A
Max. rated output current In (at 40 °C ambient temperature) 63 A
Rated insulation voltage 660 V AC
Test voltage (50 Hz) 2.5 kV
Ambient conditions
Degree of protection IP20
Connecting cables 40 A (6 mm2), 63 A (10 mm2)
Connecting cable type H07VK
Ambient temperature –5 … +60 °C

System overview, page 3/5


Siemens LV 10 · 10/2021 3/83
© Siemens 2021
Appendix
© Siemens 2021
Appendix

Appendix

Conditions of sale and delivery   A/2

Link directory   A/4

Siemens LV 10 · 10/2021 A/1


© Siemens 2021
Appendix | Conditions of sale and delivery

Conditions of sale and delivery

1. General Provisions 1.2 For customers with a seat or registered office outside
By using this catalog you can purchase products (hardware, European Union
software and services) described therein from Siemens Aktien­ For customers with a seat or registered office outside European
gesellschaft subject to the following Terms and Conditions of Union, the following terms and conditions apply subordinate to
Sale and Delivery (hereinafter referred to as „T&C“). Please note T&C:
that the scope, the quality and the conditions for supplies and
• for products, which include specific terms and conditions in
services, including software products, by any Siemens entity
the description text, these specific terms and conditions shall
having a registered office outside Germany, shall be subject
apply and subordinate thereto,
exclusively to the General Terms and Conditions of the respective
• for consulting services the „Standard Terms and Conditions for
Siemens entity. The following T&C apply exclusively for orders
Consulting Services of the Division DF for Customers with a
placed with Siemens Aktiengesellschaft, Germany.
Seat or Registered Office Outside of Germany“1) and/or
1.1 For customers with a seat or registered office in • for other services the „International Terms & Conditions for
European Union Services“1) supplemented by „Software Licensing Conditions“1)
For customers with a seat or registered office in European Union, and/or
the following terms and conditions apply subordinate to T&C: • for other supplies of hard- and software the „International
Terms & Conditions for Products“1) supplemented by „Software
• for products, which include specific terms and conditions in Licensing Conditions“1)
the description text, these specific terms and conditions shall
apply and subordinate thereto, 1.3 For customers with master or framework agreement
• for stand-alone software products and software products To the extent our supplies and/or services offered are covered by
forming a part of a product or project, the „General License an existing master or framework agreement, the terms and
Conditions for Software Products for Automation and Drives conditions of that agreement shall apply instead of T&C.
for Customers with a Seat or registered Office in Germany“1)
2. Additional Terms and Conditions
and/or
The dimensions are in mm. In Germany, according to the German
• for consulting services the “Allgemeine Geschäftsbedingungen
law on units in measuring technology, data in inches apply only
für Beratungsleistungen der Division DF – Deutschland”
to devices for export.
(available only in German) and/or
• for other services, the „Supplementary Terms and Conditions Illustrations are not binding.
for Services (“BL”)1) and/or
Insofar as there are no remarks on the individual pages of this
• for other supplies the „General Conditions for the Supply of
catalog – especially with regard to data, dimensions and weights
Products and Services of the Electrical and Electronics
given – these are subject to change without prior notice.
Industry“1).
In case such supplies should contain Open Source Software,
the conditions of which shall prevail over the „General
Conditions for the Supply of Products and Services of the
Electrical and Electronics Industry“1), a notice will be contained
in the scope of delivery in which the applicable conditions for
Open Source Software are specified. This shall apply mutatis
mutandis for notices referring to other third party software
components.

1)
The text of the Terms and Conditions of Siemens AG can be downloaded at
https://mall.industry.siemens.com/legal/ww/en/terms_of_trade_en.pdf

A/2 Siemens LV 10 · 10/2021


© Siemens 2021
Conditions of sale and delivery | Appendix

3. Export Regulations
We shall not be obligated to fulfill any agreement if such Prior to any transfer of goods, works and services provided by us
fulfillment is prevented by any impediments arising out of to a third party you shall in particular check and guarantee by
national or international foreign trade or customs requirements appropriate measures that
or any embargoes and/or other sanctions. • there will be no infringement of an embargo imposed by the
Export may be subject to license. We shall indicate in the delivery European Union, by the United States of America and/or by the
details whether licenses are required under German, European United Nations by such transfer, by brokering of contracts
and US export lists. concerning those goods, works and services or by provision of
other economic resources in connection with those goods,
Our products are controlled by the U.S. Government (when works and services, also considering the limitations of
labeled with „ECCN“ unequal „N“) and authorized for export only domestic business and prohibitions of by-passing those
to the country of ultimate destination for use by the ultimate embargos;
consignee or end-user(s) herein identified. They may not be • such goods, works and services are not intended for use in
resold, transferred, or otherwise disposed of, to any other connection with armaments, nuclear technology or weapons,
country or to any person other than the authorized ultimate if and to the extent such use is subject to prohibition or
consignee or end-user(s), either in their original form or after authorization, unless required authorization is provided;
being incorporated into other items, without first obtaining • the regulations of all applicable Sanctioned Party Lists of the
approval from the U.S. Government or as otherwise authorized European Union and the United States of America concerning
by U.S. law and regulations. Products labeled with „AL“ unequal the trading with entities, persons and organizations listed
„N“ are subject to European/national export authorization. therein are considered.
The export indications can be viewed in advance in the descrip­ If required to enable authorities or us to conduct export control
tion of the respective goods on the Industry Mall, our online checks, you, upon request by us, shall promptly provide us with
catalog system. Only the export labels „AL“ and „ECCN“ indicated all information pertaining to the particular end customer, the
on order confirmations, delivery notes and invoices are authori- particular destination and the particular intended use of goods,
tative. works and services provided by us, as well as any export control
restrictions existing.
Products without label, with label „AL:N“/„ECCN:N“, or label
„AL:9X9999“/„ECCN: 9X9999“ may require authorization from You acknowledge that under the EU embargo regulations against
responsible authorities depending on the final end-use, or the Iran, Syria and Russia respectively the sale of certain listed goods
destination. and related services is subject to authorization by the competent
export control authorities of the European Union. If (1) the goods
If you transfer goods (hardware and/or software and/or technolo- or services ordered by you are destined for Iran, Syria or Russia,
gy as well as corresponding documentation, regardless of the and (2) the contract for our supplies and/or services is subject to
mode of provision) delivered by us or works and services prior authorization of the competent export control authorities of
(including all kinds of technical support) performed by us to a the European Union, the contract between you and us shall
third party worldwide, you shall comply with all applicable come into force in this respect only upon granting of such
national and international (re-)export control regulations. In any authorization.
event of such transfer of goods, works and services you shall
comply with the (re-) export control regulations of the Federal The products listed in this catalog may be subject to European/
Republic of Germany, of the European Union and of the United German and/or US export regulations. Any export requiring
States of America. approval is therefore subject to authorization by the relevant
authorities. Errors excepted and subject to change without prior
notice.

Siemens LV 10 · 10/2021 A/3


© Siemens 2021
Appendix | Link directory

Link directory
Catalog LV 10

General information
Information on low-voltage power distribution and electrical www.siemens.com/lowvoltage
installation technology
Tender specifications www.siemens.com/lowvoltage/tenderspecifications
Conversion tool www.siemens.com/conversion-tool
Image database www.siemens.com/lowvoltage/picturedb
CAx download manager www.siemens.com/cax
Newsletter system www.siemens.com/lowvoltage/newsletter
Siemens YouTube channel www.youtube.com/Siemens
Brochures/catalogs www.siemens.com/lowvoltage/catalogs
Operating instructions/manuals www.siemens.com/lowvoltage/manuals
Siemens Industry Online Support (SIOS) www.siemens.com/lowvoltage/product-support
Siemens Industry Online Support app www.siemens.com/support-app
My Documentation Manager (MDM) www.siemens.com/lowvoltage/mdm
Configurators www.siemens.com/lowvoltage/configurators
Siemens Industry Mall – product catalog and www.siemens.com/lowvoltage/mall
online ordering system
Direct forwarding to the Industry Mall www.siemens.com/product?Article No.
Training www.siemens.com/sitrain-lowvoltage
Local contacts www.siemens.com/lowvoltage/contact
www.siemens.com/lowvoltage/components/contact
www.siemens.com/lowvoltage/systems/contact
www.siemens.com/lowvoltage/software/contact
Technical Support www.siemens.com/support-request
Information on services www.siemens.com/service-catalog
Manual for the generation, transmission and distribution www.siemens.com/power-engineering-guide
of electrical energy
Control panels for the North American market www.siemens.com/northamerican-standards
Control panel building www.siemens.com/controlpanel
Energy savings and amortization www.automation.siemens.com/sinasave
Energy Suite www.siemens.com/energysuite
SITOP power supplies www.siemens.com/sitop
Power distribution with Totally Integrated Power www.siemens.com/tip

A/4 Siemens LV 10 · 10/2021


© Siemens 2021

Catalogs and further information

LV 10 LV 14
Low-Voltage Power Distribution and Power Monitoring Made Simple
Electrical Installation Technology SENTRON
SENTRON • SIVACON • ALPHA
PDF (E86060-K1814-A101-A8-7600)
Protection, Switching, Measuring and
SENTRON • SIVACON • ALPHA

Low-Voltage Power
Distribution and Electrical
SENTRON

Installation Technology

Monitoring Devices, Switchboards and


Power Monitoring
Protection, Switching, Measuring and Monitoring
Devices, Switchboards and Distribution Systems Made Simple
Catalog Edition Catalog Edition
LV 10 10/2021 siemens.com/lowvoltage LV 14 11/2021 siemens.com/powermonitoring

Distribution Systems
PDF (E86060-K8280-A101-B4-7600)

LV 18 ET D1
Air Circuit Breakers and Molded Case Switches and Socket Outlets
Circuit Breakers with UL Certification DELTA
SENTRON
PDF
SENTRON

Air Circuit Breakers and


Molded Case Circuit Breakers
PDF (E86060-K8280-E347-A7-7600)
with UL Certification
Catalog Edition
LV 18 10/2021 siemens.com/lowvoltage

IC 10 Industry Mall
© Siemens 2021

Industrial Controls Information and Ordering Platform


SIRIUS on the Internet:
PDF (E86060-K1010-A101-B3-7600) www.siemens.com/industrymall
SIRIUS

Industrial Controls
Catalog Edition
IC 10 2021 siemens.com/sirius

Siemens TIA Selection Tool SITRAIN


for the selection, configuration and ordering Digital Industry Academy
of TIA products and devices
www.siemens.com/sitrain
www.siemens.com/tst

The catalogs listed above and additional catalogs are Further information on low-voltage power distribution
available in PDF format at Siemens Industry Online Support and electrical installation technology is available on the
www.siemens.com/lowvoltage/catalogs Internet at www.siemens.com/lowvoltage
© Siemens 2021

Get more information Security information


www.siemens.com/lowvoltage Siemens provides products and solutions with industrial
security functions that support the secure operation of
plants, systems, machines and networks.
Published by For the U.S. published by
Siemens AG Siemens Industry Inc. In order to protect plants, systems, machines and networks
against cyber threats, it is necessary to implement – and
Smart Infrastructure continuously maintain – a holistic, state-of-the-art indus-
Electrical Products 100 Technology Drive trial security concept. Siemens’ products and solutions
Siemensstraße 10 Alpharetta, GA 30005 constitute one element of such a concept.
93055 Regensburg, Germany United States
Customers are responsible for preventing unauthorized
access to their plants, systems, machines and networks.
PDF (Catalog Extract E86060-K8280-A101-B4-7600)
KG 1021 90 En
Such systems, machines and components should only be
Produced in Germany connected to an enterprise network or the Internet if and
© Siemens 2021 to the extent such a connection is necessary and only
when appropriate security measures (e.g. firewalls and/or
network segmentation) are in place.
Subject to changes and errors. The information given in this document
only contains general descriptions and/or performance features which For additional information on industrial security measures
may not always specifically reflect those described, or which may
that may be implemented, please visit
undergo modification in the course of further development of the
products. The requested performance features are binding only when
https://www.siemens.com/industrialsecurity
they are expressly agreed upon in the concluded contract.
Siemens’ products and solutions undergo continuous
All product designations may be trademarks or other rights of development to make them more secure. Siemens strongly
Siemens AG, its affiliated companies or other companies whose recommends that product updates are applied as soon as
use by third parties for their own purposes could violate the rights
they are available and that the latest product versions are
of the respective owner.
used. Use of product versions that are no longer supported,
and failure to apply the latest updates may increase
customer's exposure to cyber threats.
To stay informed about product updates, subscribe to the
Siemens Industrial Security RSS Feed under
https://www.siemens.com/industrialsecurity

You might also like