The MVS 3.8j Tur(n)key 4- System -- Version 1.
00 -- Update 07
Installation
1. It is strongly recommended to create a backup copy of the system. Although the
update process has been thoroughly tested a backup copy comes in handy if an
unforeseen error occurs.
2. Update 01, Update 02, Update 03, Update 04, Update 05 and Update 06 are
prerequisites for Update 07. Make sure Update 01, Update 02, Update 03, Update
04, Update 05 and Update 06 have been installed successfully before trying to install
Update 07.
3. Make sure that your tk4- folder does not contain a subfolder named update. If an
update folder has been left over from the installation of a previous update (i.e. from
Update 06) either delete it or rename it.
4. Unzip archive tk4-_v1.00_update_07.zip into the tk4- folder. Allow your unzip
utility to overwrite existing files and to merge into existing folders while unzipping the
archive.
5. a) Windows: Open folder tk4\update and click (or double click, depending on your
settings) apply_update.bat.
b) Linux or OS X: Open a shell window, change directory to the tk4-/update folder
and run ./apply_update.
6. You’ll be prompted for the credentials of an administrative user (i.e. HERC01/CUL8TR),
then the system will be IPLed, an update job will be executed and the system will be
shut down.
Note 1: Although lots of informational message are displayed during the update
process most of the time, there may be update steps that will not display any
messages for a couple of minutes. This must not be misinterpreted as a stall of the
update process. Please be patient during these pauses and refrain from manually
interrupting the update process.
7. Once the update process has finished check listing.txt in the update folder for
errors. The following outcome is expected:
14.39.07 JOB 1 IEF403I UPDATER - STARTED - TIME=14.39.07
14.39.07 JOB 1 IEFACTRT - Stepname Procstep Program Retcode
14.39.07 JOB 1 UPDATER DELCAT IEFBR14 RC= 0000
14.39.07 JOB 1 UPDATER DELVOL IEFBR14 RC= 0000
14.39.07 JOB 1 UPDATER ALLOC IEFBR14 RC= 0000
14.39.07 JOB 1 *IEC501A M 480,UPDATE,SL,6250 BPI,UPDATER,CREDITS
14.39.07 JOB 1 UPDATER CREDITS IEBGENER RC= 0000
14.39.08 JOB 1 UPDATER REVIEW IEBGENER RC= 0000
14.39.08 JOB 1 UPDATER TCPIP IEBGENER RC= 0000
14.39.08 JOB 1 UPDATER TCPIPTK4 IEBGENER RC= 0000
14.39.14 JOB 1 UPDATER ELEMENTS IEBCOPY RC= 0000
14.39.14 JOB 1 IEF234E K 480,UPDATE,PVT,UPDATER
14.39.14 JOB 1 IEF404I UPDATER - ENDED - TIME=14.39.14
IPL the system and verify that your regularly used functionality still works as
expected. If it does not, revert to your backup copy and report the problems to the
author.
8. Folder tk4-/update is not needed to operate the system, once the update has been
installed successfully. It is recommended to remove it to avoid interference with future
updates.
Fixes
none
New or Changed Function
RFE/REVIEW 45.6
RFE/REVIEW release 45.3 has been replaced with release 45.6. Thanks to Greg Price for
maintaining and continuously improving RFE/REVIEW and thus bringing capabilities similar
to those of ISPF/PDF to MVS 3.8j!
Basic TCP/IP Support
Jason Winter’s TCPIP instruction (opcode X’75’) has been re-fitted to work with the Hercules
version that comes with TK4-. The instruction dates back to 2002 and was last updated
around 2009. It allows the Hercules guest to access the IP stack of the host system on which
Hercules is running. The current implementation provides the complete functionality as
designed in 2002/2009.
However, from today’s point of view, the given implementation may compromise the TK4-
security concept and attract risks from the network. Before trying to use TCP/IP connectivity
it is strongly recommended to read TSO HELP member TCPIP. Besides providing detailed
usage instructions it also explains possible risks and strategies to avoid them.
Thanks to Jason Winter for making this functionality available!
--------------------------------
Jürgen Winkelmann, [email protected], February 19, 2015