DC and AC Power Circuits Training System

579282 (8010-15)

LabVolt Series

Datasheet

Festo Didactic
en 220 V - 50 Hz
* The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section of
each product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice. 12/2021
DC and AC Power Circuits Training System, LabVolt Series

Table of Contents

General Description_________________________________________________________________________________ 2
Courseware _______________________________________________________________________________________ 3
Modular Approach__________________________________________________________________________________ 4
elearning Formats __________________________________________________________________________________ 4
Features & Benefits _________________________________________________________________________________ 4
List of Equipment___________________________________________________________________________________ 5
List of Manuals ____________________________________________________________________________________ 5
Table of Contents of the Manual(s) ____________________________________________________________________ 5
Additional Equipment Required to Perform the Exercises _________________________________________________ 6
Optional Equipment ________________________________________________________________________________ 6
System Specifications_______________________________________________________________________________ 6
Equipment Description ______________________________________________________________________________ 7
Optional Equipment Description _____________________________________________________________________ 21

General Description
The DC and AC Power Circuits Training System combines a modular design approach with computer-based data
acquisition and control to introduce students to the fundamentals of electricity, such as direct current (dc),
alternating current (ac), voltage, resistance, and Ohm's Law. The training system is designed to operate at a low
voltage to ensure the safety of students beginning their training in electric power technology.
The DC and AC Power Circuits Training System is part of the Electric Power Technology Training Systems, Series
8010. Each training system in Series 8010 is based on the Electric Power Technology Training Program and
provides a turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive
courseware provided with each training system covers all the theory required to perform the laboratory
exercises, while review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.

© Festo Didactic 2
DC and AC Power Circuits Training System, LabVolt Series

The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.

Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.

3 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Modular Approach
The modular approach for designing the training program and lab equipment enables instructors to start
building their electrical-energy laboratory with a basic package of courses and equipment and add new courses
and equipment over time without needless duplication of equipment.
All lab equipment consists of modules that can be inserted into a workstation. Module dimensions vary
between two standard EMS sizes: full-size and half-size. Symbols and diagrams representing the electrical
components in each module are clearly silk-screened on the front panel. Standard, color-coded safety banana
jacks are used to provide access to the various components in each module.

elearning Formats
The courseware is also available in three eLearning formats for users preferring a computer-based approach:

• Model 21001- E: eSeries format, facilitated by the Mind-Sight eLearning system.


• Model 21001-F: SCORM-based format, designed to be hosted by a third-party, SCORM 1.2 compliant management
system.
• Model 21001-G: Stand-alone format, available on CD-ROM. This format runs on a web browser and does not require
any management system.

Please refer to our website at www.labvolt.com for more information about the Mind-Sight, SCORM, and Stand-
Alone eLearning formats.

Features & Benefits


• The training system teaches simply and effectively the basic principles of electrical power for both direct current
(dc) and alternating current (ac).
• The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a
multitude of different customized training solutions.
• The courseware includes student manuals and instructor guides with all the theory required to perform the
hands-on experiments.
• All workstations, modules, and components are very sturdy to ensure a prolonged service life in a demanding
environment such as a training laboratory.
• The modular design approach of the training equipment allows a large variety of courses to be performed using
a small number of modules, without unnecessary duplication of equipment.
• All electrical components can be interconnected without electric shock hazard since all live parts of the
connection leads are concealed and insulated.
• All electrical symbols representing the components used in a laboratory exercise are clearly silk-screened on the
front panel of the modules.
• The training system includes two highly versatile USB peripherals:
▪ Four-Quadrant Dynamometer/Power Supply, Model 8960-2. This module is used as a dc and ac power
source.
▪ Data Acquisition and Control Interface, Model 9063. This module gives access to a large variety of
computer-based measuring instruments via the LVDAC-EMS software.
• Software upgrades for LVDAC-EMS and firmware upgrades for the Four-Quadrant Dynamometer/Power Supply
and Data Acquisition and Control Interface are available for download free of charge on the Festo Didactic
website.

© Festo Didactic 4
DC and AC Power Circuits Training System, LabVolt Series

List of Equipment
Model
Qty Description
number
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Resistive Load __________________________________________________________________ 579512 (8311-05)
1 Inductive Load __________________________________________________________________ 579517 (8321-05)
1 Capacitive Load _________________________________________________________________ 579545 (8331-05)
1 Connection Lead Set _____________________________________________________________ 579638 (8951-L0)
1 Four-Quadrant Dynamometer/Power Supply _________________________________________ 579651 (8960-C5)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063-B0)
1 24 V AC Power Supply ___________________________________________________________ 579697 (30004-25)

List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________579341 (86350-10)
Single-Phase AC Power Circuits (Workbook) _____________________________________________579366 (86358-00)
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________585219 (86718-E0)
Single-Phase AC Power Circuits (Workbook (Instructor)) _________________________________ 8141434 (86358-15)

Table of Contents of the Manual(s)


DC Power Circuits (Workbook) (579339 (86350-00))
• 1 Voltage, Current, and Ohm’s Law
• 2 Equivalent Resistance
• 3 Power in DC Circuits
• 4 Series and Parallel Circuits

Single-Phase AC Power Circuits (Workbook) (579366 (86358-00))


• 1-1 The Sine Wave
• 1-2 Phase Angle and Phase Shift
• 1-3 Instantaneous Power and Average Power
• 2-1 Inductive Reactance
• 2-2 Capacitive reactance
• 2-3 Impedance
• 3-1 Active and Reactive Power
• 3-2 Apparent Power and the Power Triangle
• 4-1 Solving Simple AC Circuits Using Circuit Impedance Calculation
• 4-2 Solving AC Circuits Using the Power Triangle Method

Electric Power Technology Training Equipment (User Guide) (584778 (38486-E0))


• 1 General Safety Recommendations
• 2 System Power Requirements
• 3 Quick Start Installation Guide
• 4 Equipment Installation
• 5 Modules Handling, Installation, and Removal
• 6 Equipment Maintenance

5 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

• A Connection of the Power Supply to the AC Power Network


• B Description, Specifications, and Operation of the EMS Modules

Computer-Based Instruments for EMS (User Guide) (585219 (86718-E0))


• 1 Familiarization with the Metering Window and the Data Table
• 2 Familiarization with the Oscilloscope
• 3 Familiarization with the Phasor Analyzer
• 4 Familiarization with the Harmonic Analyzer
• 5 Measuring Three-Phase Power Using the Metering Window

Additional Equipment Required to Perform the Exercises


Model
Qty Description
number
2 Digital Multimeter _______________________________________________________________ 579782 (8946-20)
1 Personal Computer _____________________________________________________________ 579787 (8990-05) 1

Optional Equipment
Model
Qty Description
number
1 Mobile Workstation _____________________________________________________________ 579755 (8110-20) 2
1 Tabletop Workstation ___________________________________________________________ 579484 (8134-20) 3
1 Storage Shelves _________________________________________________________________ 579756 (8150-10)
1 Full-Size Blank EMS Module _______________________________________________________ 579757 (8160-00)
1 Half-Size Blank EMS Module ______________________________________________________ 579758 (8161-00)
1 Multimeters Module ____________________________________________________________ 586888 (8946-A0) 4
1 DC and AC Power Circuits Training System (Manuals on CD-ROM) _______________________ 579716 (86358-A0)

System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)

1 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
2 Can replace the Three-Module Workstation, Model 8131.
3 Can replace the Three-Module Workstation, Model 8131.
4 Can replace the Digital Multimeter, Model 8946-2.

© Festo Didactic 6
DC and AC Power Circuits Training System, LabVolt Series

Equipment Description
Three-Module Workstation
579483 (8131-00)
The Three-Module Workstation is a fully assembled workstation
that serves the same purpose as the Mobile Workstation, Model
8110, but without any storage cabinet or pull-out work surface.
This workstation is intended for use on a bench (not supplied)
and is fitted with wooden feet to protect the bench top.
The Three-Module Workstation consists of a single row of three
full-height compartments that can accommodate up to three full-
size EMS modules or six half-size EMS modules.

Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. A front-mounted push lever allows all EMS modules on the workstation to be released for easy
removal.

Safety Padlock Bars


Two safety padlock bars on the front of the workstation prevent students from removing EMS modules during
laboratory exercises. The bars can be removed and locked to the side of the workstation when the safety lock is
not necessary.

7 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Additional Information
Three holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of
2 kW machines to their interconnection modules. Assembly of the workstation before painting ensures that
each EMS module in the workstation is correctly grounded.

Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)

Table of Contents of the Manual(s)


Electric Power Technology Training Equipment (User Guide) (584778 (38486-E0))
• 1 General Safety Recommendations
• 2 System Power Requirements
• 3 Quick Start Installation Guide
• 4 Equipment Installation
• 5 Modules Handling, Installation, and Removal
• 6 Equipment Maintenance
• A Connection of the Power Supply to the AC Power Network
• B Description, Specifications, and Operation of the EMS Modules

Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation __________________________________________ 581243 (3105-A0) 5
1 Industrial Controls Double-Rail Workstation _________________________________________ 585964 (3105-B0) 6
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136-PC)
1 Dust Cover for Workstation 8131 ___________________________________________________ 587005 (8991-10)

Specifications
Parameter Value
Physical Characteristics

5 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer

to the 8036 datasheet for more information.


6 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer

to the 8036 datasheet for more information.

© Festo Didactic 8
DC and AC Power Circuits Training System, LabVolt Series

Parameter Value
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 375 x 930 x 530 mm (14.8 x 36.6 x 20.9 in)
Net Weight TBE

Resistive Load
763359 (8311-00)
The Resistive Load consists of a module housing nine wire-
wound power resistors arranged in three identical banks. Each
bank consists of three resistors connected in parallel that can be
switched on or off with toggle switches to obtain various
resistance values. This allows the total (equivalent) resistance of
each bank to be increased or decreased by steps. Six safety
banana jacks on the module front panel provide access to each
resistor bank. The three resistor banks can be connected
separately for operation in three-phase circuits. Also, the three
resistor banks can be connected together for operation in single-
phase circuits.
The Resistive Load is commonly used in conjunction with other basic load modules, like the Inductive Load and
the Capacitive Load to experiment with the effects of different types of load on a circuit.

Specifications
Parameter Value
Resistors
Quantity Three identical banks of three resistors
Resistance Values (Each Group) 1100/2200/4400 Ω
Nominal Voltage 220 V ac/dc
Resistance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Power 11-77 W
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 4.5 kg (9.9 lb)
Color
Front panel color Blue

Resistive Load
579512 (8311-05)
The Resistive Load consists of a module housing nine wire-
wound power resistors arranged in three identical banks. Each
bank consists of three resistors connected in parallel that can be
switched on or off with toggle switches to obtain various
resistance values. This allows the total (equivalent) resistance of
each bank to be increased or decreased by steps. Six safety
banana jacks on the module front panel provide access to each
resistor bank. The three resistor banks can be connected
separately for operation in three-phase circuits. Also, the three

9 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

resistor banks can be connected together for operation in single-phase circuits.


The Resistive Load is commonly used in conjunction with other basic load modules, like the Inductive Load and
the Capacitive Load to experiment with the effects of different types of load on a circuit.

Specifications
Parameter Value
Resistors
Quantity Three identical banks of three resistors
Resistance Values (Each Group) 1100/2200/4400 Ω
Nominal Voltage 220 V ac/dc
Resistance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Power 11-77 W
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 4.5 kg (9.9 lb)
Color
Front panel color Blue

Inductive Load
579517 (8321-05)
The Inductive Load consists of a module housing nine iron-core
power inductors arranged in three identical banks. Each bank
consists of three inductors connected in parallel that can be
switched on or off with toggle switches to obtain various
inductance values. This allows the equivalent inductance of each
bank to be increased or decreased by steps. Six safety banana
jacks on the module front panel provide access to each inductor
bank. The three inductor banks can be connected separately for
operation in three-phase circuits. Also, the three inductor banks
can be connected together for operation in single-phase circuits.
The Inductive Load is commonly used in conjunction with other basic load modules, like the Resistive Load and
the Capacitive Load to experiment with the effects of different types of load on a circuit.

Specifications
Parameter Value
Inductors
Quantity Three identical banks of three inductors
Inductance Values (Each Bank) 3.5/7/14 H
Reactance Values (Each Bank) 1100/2200/4400 Ω
Nominal Voltage 220 V – 50 Hz
Inductance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Reactive Power 11-77 var
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 10.1 kg (22.3 lb)

© Festo Didactic 10
DC and AC Power Circuits Training System, LabVolt Series

Capacitive Load
579545 (8331-05)
The Capacitive Load consists of a module housing nine
capacitors arranged in three identical banks. Each bank consists
of three capacitors connected in parallel that can be switched on
or off with toggle switches to obtain various capacitance values.
This allows the equivalent capacitance of each bank to be
increased or decreased by steps. Six safety banana jacks on the
module front panel provide access to each capacitor bank. The
three capacitor banks can be connected separately for operation
in three-phase circuits. Also, the three capacitor banks can be
connected together for operation in single-phase circuits.
A permanently connected discharge resistor reduces the voltage across the terminals of each bank of capacitors
to 5% of the applied voltage within 25 seconds after the load is disconnected from the supply. The Capacitive
Load may be used with both dc and ac power.
The Capacitive Load is commonly used in conjunction with the other basic load modules, the Resistive Load and
the Inductive Load to experiment with the effects of different types of load on a circuit.

Specifications
Parameter Value
Capacitors
Quantity Three identical banks of three capacitors
Capacitance Values (Each Bank) 0.72/1.45/2.89 μF
Reactance Values (Each Bank) 1100/2200/4400 Ω
Nominal Voltage 220 V – 50 Hz
Maximum Voltage 440 V
Capacitance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Reactive Power 11-77 var
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 5.7 kg (12.6 lb)

Connection Lead Set


579638 (8951-L0)
This Connection Lead Set consists of extra-flexible leads terminated with stacking 4 mm safety banana plugs. In
addition, the set includes stacking 2 mm banana plug leads of the same length and color.

Specifications
Parameter Value
4 mm Safety Banana Plug Leads Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
4 mm Safety Banana Plug Leads Quantities
Yellow, 30 cm (12 in) 20
Red, 60 cm (24 in) 10
Blue, 90 cm (36 in) 4
2 mm Safety Banana Plug Leads Characteristics

11 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Parameter Value
Cross Section 0.5 mm² (987 cmils)
Rated Current 10 A
Rated Voltage 30 V ac / 60 V dc
2 mm Safety Banana Plug Leads Quantities
Red, 60 cm (24 in) 4

Four-Quadrant Dynamometer/Power Supply


579651 (8960-C5)
The Four-Quadrant Dynamometer/Power Supply is a highly
versatile USB peripheral designed to be used in the Electric
Power Technology Training Systems. Two operating modes are
available: Dynamometer and Power Supply. A wide variety of
user-selectable functions is available in each operating mode.
In the Dynamometer mode, the unit becomes a four-quadrant
dynamometer that can act as either a fully configurable brake
(i.e., a mechanical load) or a fully configurable prime mover (i.e.,
a motor drive). In the Power Supply mode, the unit becomes a
four-quadrant power supply that can act as a dc voltage source,
dc current source, ac power source, etc.
In each operating mode, key parameters related to the selected function are displayed. Speed, torque,
mechanical power, and energy are displayed in the Dynamometer mode while voltage, current, electrical power,
and energy are displayed in the Power Supply mode. Optional functions, such as a small wind-turbine emulator,
a hydraulic turbine emulator, a solar panel emulator, battery chargers, an SDK (Software Development Kit) etc.,
can be added to the standard functions to further enhance the training possibilities of the Four-Quadrant
Dynamometer/Power Supply.
Two modes are available to control the function which the Four-Quadrant Dynamometer/Power Supply
performs: Manual and Computer-Based.
In the Manual control mode, the module operates as a stand-alone unit, and the function performed is selected,
set, and monitored using front-panel mounted controls and display. This mode provides access to all basic
functions. In the Computer-Based control mode, the function performed by the module is selected, set, and
monitored using the LVDAC-EMS software. In this mode, communication between the Four-Quadrant
Dynamometer/Power Supply and the host computer running the LVDAC-EMS software is achieved through a
USB connection. This mode provides access to all basic functions, as well as to additional advanced functions.
Model 8960-C includes the Four-Quadrant Dynamometer/Power Supply, Model 8960-3, with the following
function sets activated:

• Standard Functions (Manual Control), Model 8968-1


• Standard Functions (Computer-Based Control), Model 8968-2

Additional Equipment Required to Perform the Exercises


Model
Qty Description
number
1 Personal Computer _____________________________________________________________ 579787 (8990-05) 7

7 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user. Note

that only one computer is required per station.

© Festo Didactic 12
DC and AC Power Circuits Training System, LabVolt Series

Specifications
Parameter Value
Dynamometer Mode
Magnetic Torque 0 to 3 N·m (0 to 27 lbf·in)
Direction of Rotation CW / CCW
Speed 0 to 2500 r/min
Nominal Power 350 W
Power Supply Mode
DC Voltage 0 to ± 150 V
AC Voltage (RMS) 0 to 105 V (no-load)
DC Current 0 to ± 5 A
AC Current (RMS) 0 to 3.5 A
Maximum Output Power 500 W
AC Frequency 10 to 120 Hz
Control Functions
Activated Sets Standard Functions (Manual Control), Model 8968-1
Standard Functions (Computer-Based Control), Model 8968-2
Liquid-Crystal Display (LCD) 76 mm (3 in), monochrome, background-illuminated, 240 x 160 dots
Control Inputs
Command Input 0 to ± 10 V
Thermistor Input 10 kΩ, type 1
Control Outputs
Shaft Encoder Quadrature encoder (A-B) - 360 pulses/revolution - TTL compatible
Torque Output Sensitivity 0.3 N·m/V (2.655 lbf·in/V)
Speed Output Sensitivity 500 r/min/V
Communication Port USB 2.0
Power Requirements 220 V - 3 A - 50 Hz, must include live, neutral, and ground wires
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight 19.5 kg (43.0 lb)

Standard Functions (manual control) Set


581436 (8968-10)
The Standard Functions (manual control) Set is a package of control functions that can be activated in the Four-
Quadrant Dynamometer/Power Supply, Model 8960-3, enabling the module to perform a wide variety of
functions in each of its two operating modes (Dynamometer and Power Supply).
The set allows only manual control of the functions. This means that the Four-Quadrant Dynamometer/Power
Supply operates as a stand-alone unit, and the function performed is selected, set, and monitored using front-
panel mounted controls and display. The following control functions are available in the set:
Dynamometer operating mode

• Two-Quadrant, Constant-Torque Brake


• Clockwise Prime Mover/Brake
• Counterclockwise Prime Mover/Brake
• Clockwise Constant-Speed Prime Mover/Brake
• Counterclockwise Constant-Speed Prime Mover/Brake
• Positive Constant-Torque Prime Mover/Brake
• Negative Constant-Torque Prime Mover/Brake

Power Supply operating mode

• Positive Voltage Source

13 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

• Negative Voltage Source


• 200 V DC Bus
• Positive Current Source
• Negative Current Source
• 50 Hz Power Source
• 60 Hz Power Source
• Lead-Acid Battery Float Charger

Specifications
Parameter Value
Control Functions
Control Functions Two-Quadrant, Constant-Torque Brake
Clockwise Prime Mover/Brake
Counterclockwise Prime Mover/Brake
Clockwise Constant-Speed Prime Mover/Brake
Counterclockwise Constant-Speed Prime Mover/Brake
Positive Constant-Torque Prime Mover/Brake
Negative Constant-Torque Prime Mover/Brake
Positive Voltage Source
Negative Voltage Source
Positive Current Source
Negative Current Source
50 Hz Power Source
60 Hz Power Source
200 V DC Bus
Lead-Acid Battery Float Charger
Two-Quadrant, Constant-Torque Brake
Torque 0-3 N·m (26.55 lbf·in)
Clockwise/Counterclockwise Prime Mover/Brake
Speed 0-2500 r/min
Clockwise/Counterclockwise Constant-Speed Prime
Mover/Brake
Speed 0-2500 r/min
Positive/Negative Constant-Torque Prime Mover/
Brake
Torque 0-3 N·m (26.55 lbf·in)
Positive/Negative Voltage Source
Voltage 0 to ±150 V
Positive/Negative Current Source
Current 0 to ±5 A
50 Hz/60 Hz Power Source
No-Load Voltage 0-140 V
200 V DC Bus
Status On or off
Lead-Acid Battery Float Charger
Float Voltage 0-150 V

© Festo Didactic 14
DC and AC Power Circuits Training System, LabVolt Series

Standard Functions (computer-based control) Set


581437 (8968-20)
The Standard Functions (computer-based control) Set is
a package of control functions that can be activated in
the Four-Quadrant Dynamometer/Power Supply, Model
8960-3, enabling the module to perform a wide variety
of functions in each of its two operating modes
(Dynamometer and Power Supply).
The set allows only computer-based control of the
functions. This means that the function performed by
the Four-Quadrant Dynamometer/Power Supply is
selected, set, and monitored using the LVDAC-EMS
software. The following control functions are available
in the set:
Dynamometer operating mode

• Two-Quadrant, Constant-Torque Brake


• Clockwise Prime Mover/Brake
• Counterclockwise Prime Mover/Brake
• Clockwise Constant-Speed Prime Mover/Brake
• Counterclockwise Constant-Speed Prime Mover/Brake
• Positive Constant-Torque Prime Mover/Brake
• Negative Constant-Torque Prime Mover/Brake
• Four-Quadrant Constant-Speed Prime Mover/Brake
• Speed Sweep

Power Supply operating mode

• Positive Voltage Source


• Negative Voltage Source
• DC Voltage Source
• Positive Current Source
• Negative Current Source
• DC Current Source
• 50 Hz Power Source
• 60 Hz Power Source
• AC Power Source
• Lead-Acid Battery Float Charger

Specifications
Parameter Value
Control Functions
Control Functions Two-Quadrant, Constant-Torque Brake
Clockwise Prime Mover/Brake
Counterclockwise Prime Mover/Brake
Clockwise Constant-Speed Prime Mover/Brake
Counterclockwise Constant-Speed Prime Mover/Brake
Positive Constant-Torque Prime Mover/Brake
Negative Constant-Torque Prime Mover/Brake

15 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Parameter Value
Four-Quadrant, Constant-Speed Prime Mover/Brake
Speed Sweep
Mechanical Load
Positive Voltage Source
Negative Voltage Source
DC Voltage Source
Positive Current Source
Negative Current Source
DC Current Source
50 Hz Power Source
60 Hz Power Source
AC Power Source
Lead-Acid Battery Float Charger
Two-Quadrant, Constant-Torque Brake
Torque Control Software knob, 8960 module knob, or 8960 command input
Torque 0-3 N·m (26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Clockwise/Counterclockwise Prime Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Clockwise/Counterclockwise Constant-Speed Prime
Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Positive/Negative Constant-Torque Prime Mover/
Brake
Torque Control Software knob, 8960 module knob, or 8960 command input
Torque 0-3 N·m (26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Four-Quadrant, Constant-Speed Prime Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Speed Sweep
Start Speed -3000 r/min to 3000 r/min
Finish Speed -3000 r/min to 3000 r/min
Number of Steps 0-50 steps
Step Duration 2-10 s
Record Data to Table Yes or no
Pulley Ratio 24:24, 24:12, or 24:32
Mechanical Load
Load Type Flywheel, fan, grinder, conveyor, calender, crane, user defined
Inertia 0.005-1 kg·m² (0.119-23.73 lb·ft²)
Friction Torque 0.05-3 N·m (0.44-26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Positive/Negative Voltage Source
Voltage Control Software knob, 8960 module knob, or 8960 command input
Voltage 0 V to 147 V / -147 V to 0 V
DC Voltage Source
Voltage Control Software knob, 8960 module knob, or 8960 command input
Voltage -147 V to 147 V
Positive/Negative Current Source
Current Control Software knob, 8960 module knob, or 8960 command input
Current 0 A to 5 A / -5 A to 0 A
DC Current Source
Current Control Software knob, 8960 module knob, or 8960 command input
Current -5 A to 5 A
50 Hz/60 Hz Power Source

© Festo Didactic 16
DC and AC Power Circuits Training System, LabVolt Series

Parameter Value
Voltage Control Software knob, 8960 module knob, or 8960 command input
No-Load Voltage 0-140 V
AC Power Source
No-Load Voltage 0-140 V
DC Offset Correction -1000 to 1000
Frequency 10-100 Hz
Lead-Acid Battery Float Charger
Float Voltage 0-150 V

Data Acquisition and Control Interface


579680 (9063-B0)
The Data Acquisition and Control Interface (DACI) is a versatile
USB peripheral used for measuring, observing, analyzing, and
controlling electrical and mechanical parameters in electric
power systems and power electronics circuits. For these
purposes, a set of computer-based instruments as well as a
variety of control functions are available for the DACI. These
instruments and control functions are accessed through the
LVDAC-EMS software. The LVDAC-EMS software, as well as all
available upgrades, is free and can be downloaded anytime on
the Festo Didactic website.
Together, the DACI and the LVDAC-EMS software allow training in
various areas such as electric power technology, ac/dc
machines, renewable energy, transmission lines, and power electronics using modern and versatile measuring
instruments and control functions. LVDAC-EMS also offers the possibility to use pre-built SCADA interfaces for
several applications to ease the view and understanding of the process taking place. The user guide provided
allows students to quickly become familiar with the instruments and control functions available.
Model 9063-B includes the DACI, Model 9063, with the following function set activated:

• Computer-Based Instrumentation Function, Model 9069-1

Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________585219 (86718-E0)

Table of Contents of the Manual(s)


Computer-Based Instruments for EMS (User Guide) (585219 (86718-E0))
• 1 Familiarization with the Metering Window and the Data Table
• 2 Familiarization with the Oscilloscope
• 3 Familiarization with the Phasor Analyzer
• 4 Familiarization with the Harmonic Analyzer
• 5 Measuring Three-Phase Power Using the Metering Window

17 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Additional Equipment Required to Perform the Exercises


Model
Qty Description
number
1 Personal Computer _____________________________________________________________ 579785 (8990-00) 8
1 24 V AC Power Supply __________________________________________________________ 579696 (30004-20) 9
1 24 V AC Power Supply ___________________________________________________________ 579698 (30004-2A)

Optional Controller
Model
Qty Description
number
1 Complete Function Set ___________________________________________________________ 581451 (9069-00)
1 Chopper/Inverter Control Function Set ______________________________________________ 581453 (9069-20)
1 Thyristor Control Function Set _____________________________________________________ 581454 (9069-30)
1 Home Energy Production Control Function Set ________________________________________ 581455 (9069-40)
1 Three-Phase PWM Rectifier/Inverter Control Function Set _______________________________ 581456 (9069-50)
1 BLDC Motor/PMSM Control Function Set ____________________________________________ 581457 (9069-60)
1 High-Voltage DC (HVDC) Transmission System Control Function Set ______________________ 579790 (9069-70)
1 Static Var Compensator (SVC) Control Function Set ____________________________________ 581458 (9069-80)
1 Software Development Kit (SDK) _________________________________________________ 581459 (9069-90) 10
1 Synchronous Generator Control Function Set _________________________________________ 579788 (9069-A0)
1 Static Synchronous Compensator (STATCOM) Control Function Set _______________________ 581460 (9069-B0)
1 Synchroscope Function ___________________________________________________________ 579789 (9069-C0)
1 Doubly-Fed Induction Generator (DFIG) Control Function Set ____________________________ 587056 (9069-D0)
1 Power Line Series Compensation Function Set ________________________________________ 581461 (9069-S0)

Optional Equipment
Model
Qty Description
number
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 11

Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Maximum Voltage (Any Terminal vs GND) 283 V ac / 400 V dc
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)

8 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user. Only

one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo representative
to obtain the correct part number.
9 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent

variants. Contact a Festo representative to obtain the correct part number.


10 For MatLab, LabView, etc.
11 Allows monitoring of up to 5 Stations through OPC.

© Festo Didactic 18
DC and AC Power Circuits Training System, LabVolt Series

Parameter Value
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Maximum Voltage (Any Terminal vs GND) 283 V ac / 400 V dc
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Set Computer-Based Instrumentation Function, Model 9069-1
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)

19 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Computer-Based Instrumentation Function Set


581452 (9069-10)
The Computer-Based Instrumentation
Function Set, Model 9069-1, includes the
following computer-based instruments:

• Metering
• Data Table and Graph
• Oscilloscope
• Phasor Analyzer
• Harmonic Analyzer

Specifications
Parameter Value
Metering
Number of Meters 18
Sampling Window 320 ms or user adjusted through software (11.4-819 ms)
Sampling Frequency (each meter) 6.4 kHz or user adjusted through software (2.5-179.2 kHz)
Display Type Digital or analog, user selectable through software
Oscilloscope
Number of Channels 8
Vertical Sensitivity 2-500 V/div.
Time Base 0.0001-10 s/div.
Sampling Window 20 x selected time base (software triggering) / 10 x selected time base (hardware triggering)
Sampling Frequency 512 samples per measured parameter per horizontal sweep, up to a maximum of 512 kHz
Phasor Analyzer
Voltage Sensitivity 2-200 V/div.
Current Sensitivity 0.1-5 A/div.
Sampling Window 2-409 ms
Sampling Frequency (Each Phasor) 5-102.4 kHz
Harmonic Analyzer
Fundamental-Frequency Range 1-1400 Hz
Number of Harmonic Components 5 to 40, user selectable through software
Vertical Scale (Relative Scale) 0.1-10%/div.
Vertical Scale (Absolute Scale) 0.1-50 V/div., 0.01-10 A/div.
Sampling Window 10 ms to 1 s
Sampling Frequency 16-102 kHz

© Festo Didactic 20
DC and AC Power Circuits Training System, LabVolt Series

24 V AC Power Supply
579697 (30004-25)
The 24 V AC Power Supply is used to power specific
modules of the Electric Power Technology Training
Systems, such as the Data Acquisition and Control
Interface, the IGBT Chopper/Inverter, and the Power
Thyristors.

Specifications
Parameter Value
Power Requirements
Maximum Current TBE
AC Power Network Installation 220 V – 50/60 Hz, must include live, neutral, and ground wires
Power Outputs
Fixed, Single-Phase AC 24 V – 2,5 A

Optional Equipment Description


Mobile Workstation (Optional)
579755 (8110-20)
The Mobile Workstation is a ready-for-use workstation that consists of two
fully assembled modules: a Workstation, Model 8134-2, mounted on a Mobile
Storage Cabinet, Model 89117-1. Four rubber-tire swivel casters allow easy
movement of the workstation in the laboratory classroom. The lower portion of
the workstation serves as a storage cabinet with two hinged panels and a lock
handle. Immediately above the storage cabinet is a pullout work surface with a
scuff- and burn-resistant laminate finish. The upper portion of the workstation
consists of three rows of compartments designed to house EMS modules. Two
of these rows have full-height compartments while the other row has half-
height compartments. Each row of full-height compartments can
accommodate up to three full-size EMS modules or six half-size EMS modules,
whereas the row of half-height compartments can accommodate up to three
half-size EMS modules.

21 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal.

Safety Padlock Bars


Two safety padlock bars on the front of the workstation prevent students from removing EMS modules during
laboratory exercises. The bars can be removed and locked to the side of the workstation when the safety lock is
not necessary.

Additional Information
Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2
kW machines to their interconnection modules. Assembly of the workstation before painting ensures that each
EMS module in the workstation is correctly grounded.

Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)

© Festo Didactic 22
DC and AC Power Circuits Training System, LabVolt Series

Table of Contents of the Manual(s)


Electric Power Technology Training Equipment (User Guide) (584778 (38486-E0))
• 1 General Safety Recommendations
• 2 System Power Requirements
• 3 Quick Start Installation Guide
• 4 Equipment Installation
• 5 Modules Handling, Installation, and Removal
• 6 Equipment Maintenance
• A Connection of the Power Supply to the AC Power Network
• B Description, Specifications, and Operation of the EMS Modules

Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation _________________________________________ 581243 (3105-A0) 12
1 Industrial Controls Double-Rail Workstation ________________________________________ 585964 (3105-B0) 13
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136-PC)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _________ 8108708 (8990-A0)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 14
1 Mounting Stand with Articulating Arm _____________________________________________ 8108710 (36653-A0)

Specifications
Parameter Value
Physical Characteristics
Intended Location On the floor (stands on casters)
Dimensions (H x W x D) 1660 x 935 x 665 mm (65.4 x 36.8 x 26.2 in)
Net Weight 77.1 kg (170 lb)

12 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer

to the 8036 datasheet for more information.


13 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer

to the 8036 datasheet for more information.


14 Extra shelf to be mounted on side of the Mobile Workstation.

23 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Tabletop Workstation (Optional)


579484 (8134-20)
The Workstation is a fully assembled workstation that serves the
same purpose as the Mobile Workstation, Model 8110-2, but has
no storage cabinet or pull-out work surface. This workstation is
intended for use on a bench (not supplied) and is fitted with
rubber feet to protect the bench top. Alternatively, this
workstation can be mounted on either a Mobile Storage Cabinet,
Model 89117-1, to make a Mobile Workstation, Model 8110-2, or
on a Mobile Base, Model 88863, to make a mobile workstation
without storage cabinet. In that case, it is possible to mount and
lock a second Workstation, Model 8134-2, on top of the first
Workstation to double the space available for EMS modules.
The Workstation consists of three rows of compartments
designed to house EMS modules. Two of these rows have full-
height compartments while the other row has half-height
compartments. Each row of full-height compartments can
accommodate up to three full-size EMS modules or six half-size
EMS modules whereas the row of half-height compartments can accommodate up to three half-size EMS
modules.

Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal.

Safety Padlock Bars


Two safety padlock bars on the front of the workstation prevent students from removing EMS modules during
laboratory exercises. The bars can be removed and locked to the side of the workstation when the safety lock is
not necessary.

© Festo Didactic 24
DC and AC Power Circuits Training System, LabVolt Series

Additional Information
Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2
kW machines to their interconnection modules. Assembly of the workstation before painting ensures that each
EMS module in the workstation is correctly grounded.

Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)

Table of Contents of the Manual(s)


Electric Power Technology Training Equipment (User Guide) (584778 (38486-E0))
• 1 General Safety Recommendations
• 2 System Power Requirements
• 3 Quick Start Installation Guide
• 4 Equipment Installation
• 5 Modules Handling, Installation, and Removal
• 6 Equipment Maintenance
• A Connection of the Power Supply to the AC Power Network
• B Description, Specifications, and Operation of the EMS Modules

Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation _________________________________________ 581243 (3105-A0) 15
1 Industrial Controls Double-Rail Workstation ________________________________________ 585964 (3105-B0) 16
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136-PC)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _________ 8108708 (8990-A0)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Mounting Stand with Articulating Arm _____________________________________________ 8108710 (36653-A0)
1 Mobile Base ___________________________________________________________________ 587518 (88863-00)

15 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer

to the 8036 datasheet for more information.


16 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer

to the 8036 datasheet for more information.

25 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Model
Qty Description
number
1 Mobile Storage Cabinet _________________________________________________________ 587519 (89117-10)

Specifications
Parameter Value
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 890 x 935 x 465 mm (35.0 x 36.8 x 18.3 in)
Net Weight 31.8 kg (70 lb)

Storage Shelves (Optional)


579756 (8150-10)
The Storage Shelves module contains five shelves, each of which can
accommodate four full-size EMS modules or eight half-size EMS modules.
Stainless steel rails guide the modules on the storage shelves and protect
them against wear. The Storage Shelves module requires assembly. A diagram
is provided to facilitate assembly. Note that this model cannot stand by itself
and must be attached to a wall.

Optional Equipment
Model
Qty Description
number
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)

Specifications
Parameter Value
Physical Characteristics
Intended Location On the floor and attached to a wall
Dimensions (H x W x D) 1980 x 1225 x 480 mm (78 x 48.2 x 18.9 in)
Net Weight TBE

© Festo Didactic 26
DC and AC Power Circuits Training System, LabVolt Series

Full-Size Blank EMS Module (Optional)


579757 (8160-00)
The Full-Size Blank EMS Module is used to fill unused locations
in a workstation, preventing students from accessing electrical
or moving parts inside the other modules. Combined with the
use of safety bars to prevent students from removing modules,
blank EMS modules ensure student safety during lab exercises.

Specifications
Parameter Value
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 415 mm (12.1 x 11.3 x 16.3 in)
Net Weight TBE

Half-Size Blank EMS Module (Optional)


579758 (8161-00)
The Half-Size Blank EMS Module is used to fill unused locations
in a workstation, preventing students from accessing electrical
or moving parts inside the other modules. Combined with the
use of safety bars to prevent students from removing modules,
blank EMS modules ensure student safety during lab exercises.

Specifications
Parameter Value
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight TBE

27 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Digital Multimeter (Optional)


579782 (8946-20)
The Digital Multimeter consists of an Amprobe AM-510 Tool Kit
Digital Multimeter with Battery Test. It is ideal to perform
voltage, current, and resistance measurements in exercises.

Specifications
Parameter Value
Voltage
Ranges 0-600 V ac/dc
Current
Range 0-10 A ac/dc
Resistance
Range 0-40 MΩ
Physical Characteristics
Dimensions (H x W x D) 182 x 90 x 45 mm (7.17 x 3.54 x 1.77 in)
Net Weight 354 g (0.78 lb)

Multimeters Module (Optional)


586888 (8946-A0)
The Multimeters Module, Model 8946-A, consists of three Digital
Multimeters, Model 8946-2, installed on the front panel of a
half-size module. This allows the Multimeters Module to be
inserted in a Workstation, just like any other module.

Specifications
Parameter Value
Multimeters
Quantity 3
Voltage Range 0-600 V dc and ac
Current Range 0-10 A dc
Resistance Range 0-20 MΩ
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)

© Festo Didactic 28
DC and AC Power Circuits Training System, LabVolt Series

Parameter Value
Net Weight TBE

Personal Computer (Optional)


579787 (8990-05)
The Personal Computer consists of a desktop computer running
under Windows® 10. A monitor, keyboard, and mouse are
included.

Specifications
Parameter Value
Power Requirements
Current 1.05 A
Service Installation Standard single-phase ac outlet

DC and AC Power Circuits Training System (Manuals on CD-ROM) (Optional)


579716 (86358-A0)

List of Manuals
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________591259 (38486-E0)
DC Power Circuits (Workbook) ________________________________________________________591809 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________591812 (86350-10)
Single-Phase AC Power Circuits (Workbook) _____________________________________________591848 (86358-00)
Single-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________591850 (86358-10)
Computer-Based Instruments for EMS (User Guide) ______________________________________592016 (86718-E0)

29 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series

Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production,
installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification.

Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible
for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered
trademarks of their respective holders. © Festo Didactic Inc. 2021. All rights reserved.

Festo Didactic SE
Rechbergstrasse 3
73770 Denkendorf
Germany
P. +49(0)711/3467-0
F. +49(0)711/347-54-88500

Festo Didactic Inc.


607 Industrial Way West
Eatontown, NJ 07724
United States
P. +1-732-938-2000
F. +1-732-774-8573

Festo Didactic Ltée/Ltd


675 rue du Carbone
Québec QC G2N 2K7
Canada
P. +1-418-849-1000
F. +1-418-849-1666

www.labvolt.com
www.festo-didactic.com

© Festo Didactic 30