DC and Ac Power Circuits Training System: Labvolt Series
DC and Ac Power Circuits Training System: Labvolt Series
579282 (8010-15)
LabVolt Series
Datasheet
Festo Didactic
en 220 V - 50 Hz
* The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section of
each product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice. 12/2021
DC and AC Power Circuits Training System, LabVolt Series
Table of Contents
General Description_________________________________________________________________________________ 2
Courseware _______________________________________________________________________________________ 3
Modular Approach__________________________________________________________________________________ 4
elearning Formats __________________________________________________________________________________ 4
Features & Benefits _________________________________________________________________________________ 4
List of Equipment___________________________________________________________________________________ 5
List of Manuals ____________________________________________________________________________________ 5
Table of Contents of the Manual(s) ____________________________________________________________________ 5
Additional Equipment Required to Perform the Exercises _________________________________________________ 6
Optional Equipment ________________________________________________________________________________ 6
System Specifications_______________________________________________________________________________ 6
Equipment Description ______________________________________________________________________________ 7
Optional Equipment Description _____________________________________________________________________ 21
General Description
The DC and AC Power Circuits Training System combines a modular design approach with computer-based data
acquisition and control to introduce students to the fundamentals of electricity, such as direct current (dc),
alternating current (ac), voltage, resistance, and Ohm's Law. The training system is designed to operate at a low
voltage to ensure the safety of students beginning their training in electric power technology.
The DC and AC Power Circuits Training System is part of the Electric Power Technology Training Systems, Series
8010. Each training system in Series 8010 is based on the Electric Power Technology Training Program and
provides a turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive
courseware provided with each training system covers all the theory required to perform the laboratory
exercises, while review questions and unit tests allow students to test the knowledge they have gained.
The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of
this, courses and equipment from the program are available as required, either individually or in the context of a
specific training system. The program covers several different subjects in the field of electrical energy, such as
rotating machines, electrical power transmission, power electronics, home energy production from renewable
resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid
technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive
systems for small electric vehicles and cars.
© Festo Didactic 2
DC and AC Power Circuits Training System, LabVolt Series
The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the
training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this
training system.
Courseware
Each course in the training system includes a full-color student manual providing all the theoretical matter
required, guided lab-exercise procedures to be performed with the training equipment, and review questions
that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to
actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to
questions is also included with each course.
3 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Modular Approach
The modular approach for designing the training program and lab equipment enables instructors to start
building their electrical-energy laboratory with a basic package of courses and equipment and add new courses
and equipment over time without needless duplication of equipment.
All lab equipment consists of modules that can be inserted into a workstation. Module dimensions vary
between two standard EMS sizes: full-size and half-size. Symbols and diagrams representing the electrical
components in each module are clearly silk-screened on the front panel. Standard, color-coded safety banana
jacks are used to provide access to the various components in each module.
elearning Formats
The courseware is also available in three eLearning formats for users preferring a computer-based approach:
Please refer to our website at www.labvolt.com for more information about the Mind-Sight, SCORM, and Stand-
Alone eLearning formats.
© Festo Didactic 4
DC and AC Power Circuits Training System, LabVolt Series
List of Equipment
Model
Qty Description
number
1 Three-Module Workstation ________________________________________________________ 579483 (8131-00)
1 Resistive Load __________________________________________________________________ 763359 (8311-00)
1 Resistive Load __________________________________________________________________ 579512 (8311-05)
1 Inductive Load __________________________________________________________________ 579517 (8321-05)
1 Capacitive Load _________________________________________________________________ 579545 (8331-05)
1 Connection Lead Set _____________________________________________________________ 579638 (8951-L0)
1 Four-Quadrant Dynamometer/Power Supply _________________________________________ 579651 (8960-C5)
1 Data Acquisition and Control Interface ______________________________________________ 579680 (9063-B0)
1 24 V AC Power Supply ___________________________________________________________ 579697 (30004-25)
List of Manuals
Manual
Description
number
DC Power Circuits (Workbook) ________________________________________________________579339 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________579341 (86350-10)
Single-Phase AC Power Circuits (Workbook) _____________________________________________579366 (86358-00)
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)
Computer-Based Instruments for EMS (User Guide) ______________________________________585219 (86718-E0)
Single-Phase AC Power Circuits (Workbook (Instructor)) _________________________________ 8141434 (86358-15)
5 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Mobile Workstation _____________________________________________________________ 579755 (8110-20) 2
1 Tabletop Workstation ___________________________________________________________ 579484 (8134-20) 3
1 Storage Shelves _________________________________________________________________ 579756 (8150-10)
1 Full-Size Blank EMS Module _______________________________________________________ 579757 (8160-00)
1 Half-Size Blank EMS Module ______________________________________________________ 579758 (8161-00)
1 Multimeters Module ____________________________________________________________ 586888 (8946-A0) 4
1 DC and AC Power Circuits Training System (Manuals on CD-ROM) _______________________ 579716 (86358-A0)
System Specifications
Parameter Value
Power Requirements
Service Installation A standard single-phase ac outlet
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in)
Net Weight TBE
EMS Modules
Full-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in)
Half-Size Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
1 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
2 Can replace the Three-Module Workstation, Model 8131.
3 Can replace the Three-Module Workstation, Model 8131.
4 Can replace the Digital Multimeter, Model 8946-2.
© Festo Didactic 6
DC and AC Power Circuits Training System, LabVolt Series
Equipment Description
Three-Module Workstation
579483 (8131-00)
The Three-Module Workstation is a fully assembled workstation
that serves the same purpose as the Mobile Workstation, Model
8110, but without any storage cabinet or pull-out work surface.
This workstation is intended for use on a bench (not supplied)
and is fitted with wooden feet to protect the bench top.
The Three-Module Workstation consists of a single row of three
full-height compartments that can accommodate up to three full-
size EMS modules or six half-size EMS modules.
Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. A front-mounted push lever allows all EMS modules on the workstation to be released for easy
removal.
7 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Additional Information
Three holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of
2 kW machines to their interconnection modules. Assembly of the workstation before painting ensures that
each EMS module in the workstation is correctly grounded.
Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)
Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation __________________________________________ 581243 (3105-A0) 5
1 Industrial Controls Double-Rail Workstation _________________________________________ 585964 (3105-B0) 6
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136-PC)
1 Dust Cover for Workstation 8131 ___________________________________________________ 587005 (8991-10)
Specifications
Parameter Value
Physical Characteristics
5 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer
© Festo Didactic 8
DC and AC Power Circuits Training System, LabVolt Series
Parameter Value
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 375 x 930 x 530 mm (14.8 x 36.6 x 20.9 in)
Net Weight TBE
Resistive Load
763359 (8311-00)
The Resistive Load consists of a module housing nine wire-
wound power resistors arranged in three identical banks. Each
bank consists of three resistors connected in parallel that can be
switched on or off with toggle switches to obtain various
resistance values. This allows the total (equivalent) resistance of
each bank to be increased or decreased by steps. Six safety
banana jacks on the module front panel provide access to each
resistor bank. The three resistor banks can be connected
separately for operation in three-phase circuits. Also, the three
resistor banks can be connected together for operation in single-
phase circuits.
The Resistive Load is commonly used in conjunction with other basic load modules, like the Inductive Load and
the Capacitive Load to experiment with the effects of different types of load on a circuit.
Specifications
Parameter Value
Resistors
Quantity Three identical banks of three resistors
Resistance Values (Each Group) 1100/2200/4400 Ω
Nominal Voltage 220 V ac/dc
Resistance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Power 11-77 W
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 4.5 kg (9.9 lb)
Color
Front panel color Blue
Resistive Load
579512 (8311-05)
The Resistive Load consists of a module housing nine wire-
wound power resistors arranged in three identical banks. Each
bank consists of three resistors connected in parallel that can be
switched on or off with toggle switches to obtain various
resistance values. This allows the total (equivalent) resistance of
each bank to be increased or decreased by steps. Six safety
banana jacks on the module front panel provide access to each
resistor bank. The three resistor banks can be connected
separately for operation in three-phase circuits. Also, the three
9 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Specifications
Parameter Value
Resistors
Quantity Three identical banks of three resistors
Resistance Values (Each Group) 1100/2200/4400 Ω
Nominal Voltage 220 V ac/dc
Resistance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Power 11-77 W
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 4.5 kg (9.9 lb)
Color
Front panel color Blue
Inductive Load
579517 (8321-05)
The Inductive Load consists of a module housing nine iron-core
power inductors arranged in three identical banks. Each bank
consists of three inductors connected in parallel that can be
switched on or off with toggle switches to obtain various
inductance values. This allows the equivalent inductance of each
bank to be increased or decreased by steps. Six safety banana
jacks on the module front panel provide access to each inductor
bank. The three inductor banks can be connected separately for
operation in three-phase circuits. Also, the three inductor banks
can be connected together for operation in single-phase circuits.
The Inductive Load is commonly used in conjunction with other basic load modules, like the Resistive Load and
the Capacitive Load to experiment with the effects of different types of load on a circuit.
Specifications
Parameter Value
Inductors
Quantity Three identical banks of three inductors
Inductance Values (Each Bank) 3.5/7/14 H
Reactance Values (Each Bank) 1100/2200/4400 Ω
Nominal Voltage 220 V – 50 Hz
Inductance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Reactive Power 11-77 var
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 10.1 kg (22.3 lb)
© Festo Didactic 10
DC and AC Power Circuits Training System, LabVolt Series
Capacitive Load
579545 (8331-05)
The Capacitive Load consists of a module housing nine
capacitors arranged in three identical banks. Each bank consists
of three capacitors connected in parallel that can be switched on
or off with toggle switches to obtain various capacitance values.
This allows the equivalent capacitance of each bank to be
increased or decreased by steps. Six safety banana jacks on the
module front panel provide access to each capacitor bank. The
three capacitor banks can be connected separately for operation
in three-phase circuits. Also, the three capacitor banks can be
connected together for operation in single-phase circuits.
A permanently connected discharge resistor reduces the voltage across the terminals of each bank of capacitors
to 5% of the applied voltage within 25 seconds after the load is disconnected from the supply. The Capacitive
Load may be used with both dc and ac power.
The Capacitive Load is commonly used in conjunction with the other basic load modules, the Resistive Load and
the Inductive Load to experiment with the effects of different types of load on a circuit.
Specifications
Parameter Value
Capacitors
Quantity Three identical banks of three capacitors
Capacitance Values (Each Bank) 0.72/1.45/2.89 μF
Reactance Values (Each Bank) 1100/2200/4400 Ω
Nominal Voltage 220 V – 50 Hz
Maximum Voltage 440 V
Capacitance Value Accuracy ± 5%
Load at Nominal Voltage (Each Bank)
Reactive Power 11-77 var
Current 0.05-0.35 A
Steps Seven, of equal increment
Current Increment 0.05 A
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 5.7 kg (12.6 lb)
Specifications
Parameter Value
4 mm Safety Banana Plug Leads Characteristics
Cross Section 1 mm² (1974 cmil)
Rated Current 19 A
Rated Voltage 600 V, CAT II
4 mm Safety Banana Plug Leads Quantities
Yellow, 30 cm (12 in) 20
Red, 60 cm (24 in) 10
Blue, 90 cm (36 in) 4
2 mm Safety Banana Plug Leads Characteristics
11 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Parameter Value
Cross Section 0.5 mm² (987 cmils)
Rated Current 10 A
Rated Voltage 30 V ac / 60 V dc
2 mm Safety Banana Plug Leads Quantities
Red, 60 cm (24 in) 4
7 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user. Note
© Festo Didactic 12
DC and AC Power Circuits Training System, LabVolt Series
Specifications
Parameter Value
Dynamometer Mode
Magnetic Torque 0 to 3 N·m (0 to 27 lbf·in)
Direction of Rotation CW / CCW
Speed 0 to 2500 r/min
Nominal Power 350 W
Power Supply Mode
DC Voltage 0 to ± 150 V
AC Voltage (RMS) 0 to 105 V (no-load)
DC Current 0 to ± 5 A
AC Current (RMS) 0 to 3.5 A
Maximum Output Power 500 W
AC Frequency 10 to 120 Hz
Control Functions
Activated Sets Standard Functions (Manual Control), Model 8968-1
Standard Functions (Computer-Based Control), Model 8968-2
Liquid-Crystal Display (LCD) 76 mm (3 in), monochrome, background-illuminated, 240 x 160 dots
Control Inputs
Command Input 0 to ± 10 V
Thermistor Input 10 kΩ, type 1
Control Outputs
Shaft Encoder Quadrature encoder (A-B) - 360 pulses/revolution - TTL compatible
Torque Output Sensitivity 0.3 N·m/V (2.655 lbf·in/V)
Speed Output Sensitivity 500 r/min/V
Communication Port USB 2.0
Power Requirements 220 V - 3 A - 50 Hz, must include live, neutral, and ground wires
A currently available personal computer with USB 2.0 ports, running under one of the following operating
Computer Requirements
systems: Windows® 7 or Windows® 8.
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 490 mm (12.1 x 11.3 x 19.3 in)
Net Weight 19.5 kg (43.0 lb)
13 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Specifications
Parameter Value
Control Functions
Control Functions Two-Quadrant, Constant-Torque Brake
Clockwise Prime Mover/Brake
Counterclockwise Prime Mover/Brake
Clockwise Constant-Speed Prime Mover/Brake
Counterclockwise Constant-Speed Prime Mover/Brake
Positive Constant-Torque Prime Mover/Brake
Negative Constant-Torque Prime Mover/Brake
Positive Voltage Source
Negative Voltage Source
Positive Current Source
Negative Current Source
50 Hz Power Source
60 Hz Power Source
200 V DC Bus
Lead-Acid Battery Float Charger
Two-Quadrant, Constant-Torque Brake
Torque 0-3 N·m (26.55 lbf·in)
Clockwise/Counterclockwise Prime Mover/Brake
Speed 0-2500 r/min
Clockwise/Counterclockwise Constant-Speed Prime
Mover/Brake
Speed 0-2500 r/min
Positive/Negative Constant-Torque Prime Mover/
Brake
Torque 0-3 N·m (26.55 lbf·in)
Positive/Negative Voltage Source
Voltage 0 to ±150 V
Positive/Negative Current Source
Current 0 to ±5 A
50 Hz/60 Hz Power Source
No-Load Voltage 0-140 V
200 V DC Bus
Status On or off
Lead-Acid Battery Float Charger
Float Voltage 0-150 V
© Festo Didactic 14
DC and AC Power Circuits Training System, LabVolt Series
Specifications
Parameter Value
Control Functions
Control Functions Two-Quadrant, Constant-Torque Brake
Clockwise Prime Mover/Brake
Counterclockwise Prime Mover/Brake
Clockwise Constant-Speed Prime Mover/Brake
Counterclockwise Constant-Speed Prime Mover/Brake
Positive Constant-Torque Prime Mover/Brake
Negative Constant-Torque Prime Mover/Brake
15 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Parameter Value
Four-Quadrant, Constant-Speed Prime Mover/Brake
Speed Sweep
Mechanical Load
Positive Voltage Source
Negative Voltage Source
DC Voltage Source
Positive Current Source
Negative Current Source
DC Current Source
50 Hz Power Source
60 Hz Power Source
AC Power Source
Lead-Acid Battery Float Charger
Two-Quadrant, Constant-Torque Brake
Torque Control Software knob, 8960 module knob, or 8960 command input
Torque 0-3 N·m (26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Clockwise/Counterclockwise Prime Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Clockwise/Counterclockwise Constant-Speed Prime
Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Positive/Negative Constant-Torque Prime Mover/
Brake
Torque Control Software knob, 8960 module knob, or 8960 command input
Torque 0-3 N·m (26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Four-Quadrant, Constant-Speed Prime Mover/Brake
Speed Control Software knob, 8960 module knob, or 8960 command input
Speed 0-2500 r/min
Pulley Ratio 24:24, 24:12, or 24:32
Speed Sweep
Start Speed -3000 r/min to 3000 r/min
Finish Speed -3000 r/min to 3000 r/min
Number of Steps 0-50 steps
Step Duration 2-10 s
Record Data to Table Yes or no
Pulley Ratio 24:24, 24:12, or 24:32
Mechanical Load
Load Type Flywheel, fan, grinder, conveyor, calender, crane, user defined
Inertia 0.005-1 kg·m² (0.119-23.73 lb·ft²)
Friction Torque 0.05-3 N·m (0.44-26.55 lbf·in)
Pulley Ratio 24:24, 24:12, or 24:32
Positive/Negative Voltage Source
Voltage Control Software knob, 8960 module knob, or 8960 command input
Voltage 0 V to 147 V / -147 V to 0 V
DC Voltage Source
Voltage Control Software knob, 8960 module knob, or 8960 command input
Voltage -147 V to 147 V
Positive/Negative Current Source
Current Control Software knob, 8960 module knob, or 8960 command input
Current 0 A to 5 A / -5 A to 0 A
DC Current Source
Current Control Software knob, 8960 module knob, or 8960 command input
Current -5 A to 5 A
50 Hz/60 Hz Power Source
© Festo Didactic 16
DC and AC Power Circuits Training System, LabVolt Series
Parameter Value
Voltage Control Software knob, 8960 module knob, or 8960 command input
No-Load Voltage 0-140 V
AC Power Source
No-Load Voltage 0-140 V
DC Offset Correction -1000 to 1000
Frequency 10-100 Hz
Lead-Acid Battery Float Charger
Float Voltage 0-150 V
Manual
Manual
Description
number
Computer-Based Instruments for EMS (User Guide) ______________________________________585219 (86718-E0)
17 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Optional Controller
Model
Qty Description
number
1 Complete Function Set ___________________________________________________________ 581451 (9069-00)
1 Chopper/Inverter Control Function Set ______________________________________________ 581453 (9069-20)
1 Thyristor Control Function Set _____________________________________________________ 581454 (9069-30)
1 Home Energy Production Control Function Set ________________________________________ 581455 (9069-40)
1 Three-Phase PWM Rectifier/Inverter Control Function Set _______________________________ 581456 (9069-50)
1 BLDC Motor/PMSM Control Function Set ____________________________________________ 581457 (9069-60)
1 High-Voltage DC (HVDC) Transmission System Control Function Set ______________________ 579790 (9069-70)
1 Static Var Compensator (SVC) Control Function Set ____________________________________ 581458 (9069-80)
1 Software Development Kit (SDK) _________________________________________________ 581459 (9069-90) 10
1 Synchronous Generator Control Function Set _________________________________________ 579788 (9069-A0)
1 Static Synchronous Compensator (STATCOM) Control Function Set _______________________ 581460 (9069-B0)
1 Synchroscope Function ___________________________________________________________ 579789 (9069-C0)
1 Doubly-Fed Induction Generator (DFIG) Control Function Set ____________________________ 587056 (9069-D0)
1 Power Line Series Compensation Function Set ________________________________________ 581461 (9069-S0)
Optional Equipment
Model
Qty Description
number
1 SCADA for LVDAC-EMS ________________________________________________________ 8094377 (8973-00) 11
Specifications
Parameter Value
Insulated Voltage Inputs (4)
Range (Low / High Scales) -80 to +80 V / -800 to + 800 V (user-selectable through software)
Impedance (Low / High Scales) 326.6 kΩ / 3.25 MΩ
Bandwidth DC to 65 kHz (-3 dB)
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Maximum Voltage (Any Terminal vs GND) 283 V ac / 400 V dc
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Insulated Current Inputs (4)
Range (Low / High Scales) -4 to +4 A / -40 to + 40 A (25 A rms)
Impedance (Low / High Scales) 5 mΩ / 50 mΩ
Bandwidth DC to 65 kHz (-3 dB)
8 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user. Only
one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo representative
to obtain the correct part number.
9 Required if power is not supplied by the Power Supply, Model 8821-2. This model is available in multiple voltage- and frequency dependent
© Festo Didactic 18
DC and AC Power Circuits Training System, LabVolt Series
Parameter Value
Accuracy 1% (dc to 10 kHz)
Insulation 800 V
Maximum Voltage (Any Terminal vs GND) 283 V ac / 400 V dc
Measurement Category CAT II (283 V ac/400 V dc versus ground)
Analog Inputs (8)
Voltage Range -10 to +10 V
Impedance > 10 MΩ
Bandwidth DC to 125 kHz
Measured Parameters User-selectable through software
Parameter-to-Voltage Ratio User-determined through software
A/D Converter for Insulated and Analog Inputs (16)
Type Successive approximation
Resolution 12 bits
Integral Non-Linearity ≤ ±1.5 LSB
Differential Non-Linearity ≤ ±1 LSB
Maximum Sampling Rate 600 ksamples/s (one channel)
FIFO Buffer Size 16 ksamples
Analog Outputs (2)
Voltage Range -10 to +10 V
Operational Load Impedance > 600 Ω
D/A Converter for Analog Outputs (2)
Type Resistor string
Resolution 12 bits
Integral Non-Linearity ≤ ±8 LSB
Differential Non-Linearity -0.5 to +0.7 LSB
Digital Inputs (3)
Types Encoder (2), synchronization (1)
Signal Level 0-5 V (TTL compatible)
Maximum Input Frequency 50 kHz
Impedance 5 kΩ
Digital Outputs (9)
Types Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector)
Signal Level 0-5 V (TTL compatible)
Maximum Output Frequency 20 kHz (software-limited)
Impedance 200 Ω
Control Functions
Activated Set Computer-Based Instrumentation Function, Model 9069-1
Computer I/O Interface USB 2.0 full speed via type-B receptacle
Power Requirements 24 V - 0.4 A - 50/60 Hz
Accessories
Included Accessories 2 m USB interconnection cable (1)
24 V power cable (1)
2 mm banana plug test leads (3)
DB9 connector control cable (1)
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight 3.9 kg (8.6 lb)
19 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
• Metering
• Data Table and Graph
• Oscilloscope
• Phasor Analyzer
• Harmonic Analyzer
Specifications
Parameter Value
Metering
Number of Meters 18
Sampling Window 320 ms or user adjusted through software (11.4-819 ms)
Sampling Frequency (each meter) 6.4 kHz or user adjusted through software (2.5-179.2 kHz)
Display Type Digital or analog, user selectable through software
Oscilloscope
Number of Channels 8
Vertical Sensitivity 2-500 V/div.
Time Base 0.0001-10 s/div.
Sampling Window 20 x selected time base (software triggering) / 10 x selected time base (hardware triggering)
Sampling Frequency 512 samples per measured parameter per horizontal sweep, up to a maximum of 512 kHz
Phasor Analyzer
Voltage Sensitivity 2-200 V/div.
Current Sensitivity 0.1-5 A/div.
Sampling Window 2-409 ms
Sampling Frequency (Each Phasor) 5-102.4 kHz
Harmonic Analyzer
Fundamental-Frequency Range 1-1400 Hz
Number of Harmonic Components 5 to 40, user selectable through software
Vertical Scale (Relative Scale) 0.1-10%/div.
Vertical Scale (Absolute Scale) 0.1-50 V/div., 0.01-10 A/div.
Sampling Window 10 ms to 1 s
Sampling Frequency 16-102 kHz
© Festo Didactic 20
DC and AC Power Circuits Training System, LabVolt Series
24 V AC Power Supply
579697 (30004-25)
The 24 V AC Power Supply is used to power specific
modules of the Electric Power Technology Training
Systems, such as the Data Acquisition and Control
Interface, the IGBT Chopper/Inverter, and the Power
Thyristors.
Specifications
Parameter Value
Power Requirements
Maximum Current TBE
AC Power Network Installation 220 V – 50/60 Hz, must include live, neutral, and ground wires
Power Outputs
Fixed, Single-Phase AC 24 V – 2,5 A
21 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal.
Additional Information
Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2
kW machines to their interconnection modules. Assembly of the workstation before painting ensures that each
EMS module in the workstation is correctly grounded.
Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)
© Festo Didactic 22
DC and AC Power Circuits Training System, LabVolt Series
Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation _________________________________________ 581243 (3105-A0) 12
1 Industrial Controls Double-Rail Workstation ________________________________________ 585964 (3105-B0) 13
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136-PC)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _________ 8108708 (8990-A0)
1 External Shelf for the Mobile Workstation _________________________________________ 581465 (36653-00) 14
1 Mounting Stand with Articulating Arm _____________________________________________ 8108710 (36653-A0)
Specifications
Parameter Value
Physical Characteristics
Intended Location On the floor (stands on casters)
Dimensions (H x W x D) 1660 x 935 x 665 mm (65.4 x 36.8 x 26.2 in)
Net Weight 77.1 kg (170 lb)
12 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer
23 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Module Installation
The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the
workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A
holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the
workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal.
© Festo Didactic 24
DC and AC Power Circuits Training System, LabVolt Series
Additional Information
Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2
kW machines to their interconnection modules. Assembly of the workstation before painting ensures that each
EMS module in the workstation is correctly grounded.
Manual
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________584778 (38486-E0)
Optional Equipment
Model
Qty Description
number
1 Industrial Controls Single-Rail Workstation _________________________________________ 581243 (3105-A0) 15
1 Industrial Controls Double-Rail Workstation ________________________________________ 585964 (3105-B0) 16
1 Mounting Frame (DIN A4) for EMS Workstations _____________________________________ 8138160 (8136-PC)
1 All-in-One Touch Screen Computer (including Monitor Stand with Articulating Arm) _________ 8108708 (8990-A0)
1 Dust Cover for Workstations _______________________________________________________ 587004 (8991-00)
1 Mounting Stand with Articulating Arm _____________________________________________ 8108710 (36653-A0)
1 Mobile Base ___________________________________________________________________ 587518 (88863-00)
15 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer
25 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Model
Qty Description
number
1 Mobile Storage Cabinet _________________________________________________________ 587519 (89117-10)
Specifications
Parameter Value
Physical Characteristics
Intended Location On a table able to support the weight of the workstation and installed equipment
Dimensions (H x W x D) 890 x 935 x 465 mm (35.0 x 36.8 x 18.3 in)
Net Weight 31.8 kg (70 lb)
Optional Equipment
Model
Qty Description
number
1 Dust Cover for EMS Storage Cabinet ________________________________________________ 587006 (8992-00)
Specifications
Parameter Value
Physical Characteristics
Intended Location On the floor and attached to a wall
Dimensions (H x W x D) 1980 x 1225 x 480 mm (78 x 48.2 x 18.9 in)
Net Weight TBE
© Festo Didactic 26
DC and AC Power Circuits Training System, LabVolt Series
Specifications
Parameter Value
Physical Characteristics
Dimensions (H x W x D) 308 x 287 x 415 mm (12.1 x 11.3 x 16.3 in)
Net Weight TBE
Specifications
Parameter Value
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in)
Net Weight TBE
27 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Specifications
Parameter Value
Voltage
Ranges 0-600 V ac/dc
Current
Range 0-10 A ac/dc
Resistance
Range 0-40 MΩ
Physical Characteristics
Dimensions (H x W x D) 182 x 90 x 45 mm (7.17 x 3.54 x 1.77 in)
Net Weight 354 g (0.78 lb)
Specifications
Parameter Value
Multimeters
Quantity 3
Voltage Range 0-600 V dc and ac
Current Range 0-10 A dc
Resistance Range 0-20 MΩ
Physical Characteristics
Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
© Festo Didactic 28
DC and AC Power Circuits Training System, LabVolt Series
Parameter Value
Net Weight TBE
Specifications
Parameter Value
Power Requirements
Current 1.05 A
Service Installation Standard single-phase ac outlet
List of Manuals
Manual
Description
number
Electric Power Technology Training Equipment (User Guide) ________________________________591259 (38486-E0)
DC Power Circuits (Workbook) ________________________________________________________591809 (86350-00)
DC Power Circuits (Workbook (Instructor)) ______________________________________________591812 (86350-10)
Single-Phase AC Power Circuits (Workbook) _____________________________________________591848 (86358-00)
Single-Phase AC Power Circuits (Workbook (Instructor)) ___________________________________591850 (86358-10)
Computer-Based Instruments for EMS (User Guide) ______________________________________592016 (86718-E0)
29 © Festo Didactic
DC and AC Power Circuits Training System, LabVolt Series
Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production,
installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification.
Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible
for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered
trademarks of their respective holders. © Festo Didactic Inc. 2021. All rights reserved.
Festo Didactic SE
Rechbergstrasse 3
73770 Denkendorf
Germany
P. +49(0)711/3467-0
F. +49(0)711/347-54-88500
www.labvolt.com
www.festo-didactic.com
© Festo Didactic 30