1. Prior to test make sure that all glassware and equipments are ok and neat & clean.
2. Lactometer must not touch the walls of cylinder.
3. Foam must be removed over the sample.
4. Temperature of milk sample must be maintained at 20° C.
Hygiene requirements:
After performing the test clean and wash all the related apparatus and glassware.
Reference:
1. FAO Manual of Food Quality Control, 14/8, page 12-1986-determination of total solid
(Rapid method) milk.
2. Sommer, Hugo H. 1938. Page 179 in Market Milk and Related Products. Madison.
Wisconsin.
Page 10 of 23
Milk Analysis Methods For Dairies of Pakistan
Page 11 of 23
Milk Analysis Methods For Dairies of Pakistan
Page 12 of 23
Milk Analysis Methods For Dairies of Pakistan
Page 13 of 23
Milk Analysis Methods For Dairies of Pakistan
Hygiene requirements:
After performing taking the sample clean and wash all the accessories and place them at their
proper and designated places.
Reference:
Manufacturer Literature.
Page 14 of 23
Milk Analysis Methods For Dairies of Pakistan
Description of a rapid direct potentiometer method that measures sodium in fresh milk and
reconstituted milk powder using an ion-selective electrode and a potentiometer.
Standard:
Reagents/Chemicals Required: 1. Nitric acid (65%), sodium chloride (extra pure)
2. Triethanolamine,
3. ISA solution
4. Electrode rinsing solution
5. Electrode storage solution
6. Sodium standard solution
Apparatus Required: 1. Magnetic stirring bar.
2. CSCE with BNC connector.
3. pH meter with BNC connector.
4. Plastic lab. Ware.
5. Volumetric flask.
Sample Preparation:
Fresh Milk:
Take 50 mL of fresh milk into a 100 mL beaker. Adjust pH of milk sample to above 9 by addition
of ISA solution (approx. 1.7 mL).
Milk Powder:
Weigh 5 g of powder in a 100 mL volumetric flask and add 60 mL warm wate (60°C) and mix
well.
Cool it to room temperature, adjust pH to above 9.0 by adding approx. 1.7 mL of ISA solution
and make up to the mark with water.
Instrument Check:
1. Make sure that the pH meter is operating the mV mode. Perform an electrode slope check
before commencing analysis of sample solution the change in potential observed when the
sodium concentration changes by a factor of10 should be 56±2 mV.
Calibration Procedure:
As per brochure of Equipment
Procedure 1:
1. Transfer 50ml sample solution into a 100 ml beaker.
2. Add 1.7 ml ISA solution check that the pH>9.0.
3. Immerse the electrode into the beaker and measure under slow magnetic stirring. It takes
10-20 seconds for the reading to stabilize; in the case of the Hach meter, an acoustic signal
is emitted and “ready “ will be display on the right side of the LED display.
4. Note the mV reading and remove the electrode.
5. Rinse the electrode thoroughly with rinsing solution and keep the electrode between
measurements in the electrode storage solution (5.3).
Procedure 2:
Following is the procedure for Sodium determination of the raw milk
1. Take sample and heat it till temperature 20-25°C.
2. Take 50-60 ml of this sample in 100 ml plastic beaker.
3. Place that beaker on the magnetic stirrer and start stirring it (100-rpm aprox.
Not more than it).
Page 15 of 23
Milk Analysis Methods For Dairies of Pakistan
V. {(C.D)-B}/m
Where
F= 1.034 Factor to compensate dilution of milk with ISA solution)
V= Volume of analytical solution in mL (normally 100 mL)
C=Conc. Sodium in analytical solution, in mg/L
D= Dilution factor if required
B= conc. Of sodium in blank solution, in mg/L
m=mass of milk powder analyzed, in gram
Repeatability & The difference between two independent single test results, within
Reproducibility: a short interval of time should not exceed 5% of their average
value
Precautions:
1. Always use plastic beaker for this test.
2. Sodium meter require calibration after at least 48 hrs or when needed.
3. Always store the electrode after proper washing and cleaning in its storage
bottle when not in use.
4. Reading stabilizes in 3-4 minutes but some times take more or less time
depending upon the sample condition.
5. If reading is not stabilizing then contact the under signed.
Reference:
1. Instruction Manual, hach Model 50310 Combination Sodium calomel Electrode (pp 1-30).
2. AOAC Official method 976.25. Sodium in Foods for Special Dietry Use. Ion Selective
Electrode Method. AOAC 1995.
3. Ion Selective Electrodes, Honold, F. & camman, K., Chapter 4, Pg 75. In: Rapid methods
for Analyses of Food and Food Raw Material. (Ed.) baltes, W. technomic Publishing Co.,
Lancaster, basel, 1990.
Page 16 of 23
Milk Analysis Methods For Dairies of Pakistan
Page 17 of 23
Milk Analysis Methods For Dairies of Pakistan
Page 18 of 23
Milk Analysis Methods For Dairies of Pakistan
Page 19 of 23
Milk Analysis Methods For Dairies of Pakistan
Page 21 of 23
Milk Analysis Methods For Dairies of Pakistan
4. Heats that cream in spoon on either direct flame of fire or any other heating source so that
fat is chard out from cream (with least possible water in it).
Cream:
Take some cream sample in spoon and heat it either on direct flam of fire or any other heating
source so that fat is chard out from cream with least possible water in it.
Ghee and oils:
No need to prepare sample for refractive index/BR value determination.
Page 22 of 23
Milk Analysis Methods For Dairies of Pakistan
Acid and heat coagulate the casein of fresh milk; the coagulated casein is separated from serum
by filtration. The brix value of filtrate indicates the total solids present in it except casein protein.
So by subtracting the value of brix from SNF of milk sample we obtained the amount of casein
that is coagulated. The lesser the amount means more the adulterants present in milk.
Reagents Required: 1. Sulphuric Acid (d=1.816 ± 0.003 g/ml, 90 – 91% purity
with clear color).
Glass Ware & Equipment 1. Glass funnel
Required: 2. Stand.
3. Filter Paper (Whatman # 42).
4. Glass Beaker 100 ml.
5. Hand Refrectometer (0-32 % brix).
Procedure:
1. Rinse the milk sample well and take 10.94 ml in a 100 ml beaker with the help of a milk
pipette.
2. Add 0.05 ml Conc. H2SO4 and mix thoroughly.
3. Heat the sample in hot water bath at 60-65°C for 5-10 seconds.
4. Filter the contents with filter paper.
5. Cool down the filtrate to 20°C.
6. Find the Brix of filtrate with the help of Hand Refrectometer and note it.
Calculations: (SNF of milk sample – Brix value) X 9
________________________________
SNF of milk sample
Results: For pure milk the resultant value must always be upto
1.25 or more, the value below 1 indicates any type of
adulteration in milk.