0% found this document useful (0 votes)
142 views1 page

Radiographic Examination Report: TC-6677

1. The report details the radiographic testing of two welds - one by welder Ramesh Sahani and another on a 21.3 diameter joint. Both welds were found to have no significant defects and were accepted. 2. The material tested was 3.73mm thick stainless steel 304. Radiographs were taken using an X-ray source at 150kV with a 1.5x1.5mm focal spot. Two films were produced at 5x4 inches each. 3. The radiographic testing was performed according to ASME Section

Uploaded by

Charles Jacob
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views1 page

Radiographic Examination Report: TC-6677

1. The report details the radiographic testing of two welds - one by welder Ramesh Sahani and another on a 21.3 diameter joint. Both welds were found to have no significant defects and were accepted. 2. The material tested was 3.73mm thick stainless steel 304. Radiographs were taken using an X-ray source at 150kV with a 1.5x1.5mm focal spot. Two films were produced at 5x4 inches each. 3. The radiographic testing was performed according to ASME Section

Uploaded by

Charles Jacob
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PALLAKKI NDT EXCELLENCE CENTER PVT. LTD.

No. 411/A, 11th Cross, 4th Phase, Peenya Industrial Area,


Bangalore - 560 058 (Karnataka, India), Phone : 080-28360717, 41270949, 41147312
Mobile : +91 94480 60717, +91 94483 70954, +91 80889 38938
Email : [email protected], [email protected], [email protected]
TC-6677

RADIOGRAPHIC EXAMINATION REPORT


Customer : STAINLESS VESSELS FABRICATORS ULR : TC667721000024849F
No.117/D,9th 'A' Cross,Ganapathi Nagar, Report No. : PNEC/RT/21-22/N/3701 Date : 09/12/2021
3rd Phase,Peenya Indl.Area. Exam. Date : 08/12/2021
Bengaluru - 560 058. (Karnataka, India) Test Carr. Out At : Our Lab
Customer Client :
Customer DC. No.: 2352
TS RT No. : SL.No : 1283
Type of Job : Weld Zone Sensitivity : 2%
Job Description : Weld Test Coupon Source Used : X-Rays
Material : SS 304 Serial No. : X - Ray 1-XXG-2505 (250 kv)
Material Thick. : 3.73 Source Strength/KV : 150
PO No. : SVF/PO/39/2021-22 Source Size / Focal Spot : 1.5 X 1.5mm
Density Range : 2 to 4 Radiation Source : X-Rays
Exposure Tech. : DWDI
Ref. Code/Std. : ASME Sec V Art 2 Placement of IQI : Source Side
Proc. & Rev. No. : PNECPL/RT/W/01 Rev 2 Placement of Lead Symbol B : Yes
Acc. Criteria : ASME Sec IX,QW-191.1.2 IQI Type : Wire
Extent of Exam. : 100% Exposure Time : 0.4 Mim
Screen (F&B) : 0.1 mm Processing Time : 05 Min
UOM : Shim (in mm) : N/A
Reinforcement Thick. : -
Sr. Thick. RFC Optical Film
Identification SFD SOD IQI Loc. Find. Lev. Result
No. (mm) Thick. Density Size
1 Welder Name : Ramesh 3.73 - 762 - 1A06 2 to 4 5 X 4" A NSD NAP ACCEPTED
Sahani
Welder Code : SVF W-8
2 Dia 21.3 Joint : J1 3.73 - 762 - 1A06 2 to 4 5 X 4" B NSD NAP ACCEPTED

Total No. of Films :2 Film Size : 5 X 4" - 2


Total Sq. Inches : 40.00 Film Brand & Speed : Film - Agfa D7
Special Note
:
Loc. = Location , Find. = Finding, Lev. = Level, SFD = Source to Film Distance, SOD = Source to Object Distance, SSOFD = Source Side of Object to Film Distance
WELDING STANDARD DEFECTS
NSD: No Significant Defect, P: Porosity, LOF: Lack of Fusion, RT: Root Cavity, SDP: Surface Depression, LOP: Lack of Penetration,
GH: Gas Hole, BT: Burn Through, SP: Scattered Porosity, AP: Aligned Porosity, TI: Tungsten Inclusion, CP: Cluster Porosity, SI: Slag Inclusion,
SB: Suck Back, UC: Under Cut, EP: Excessive Penetration, MM: Mismatch, GW: Gas Worms, CK: Crack, NAP: Not Applicable

Notes : ● Report relates items tested only. ● Test Results are in compliance with requirements and / or specifications of technique used. ● Test Reports shall not be
reproduced except full in written approval of the Laboratory. ● If balance material is available after testing, it will be retained for 15 days maximum. ● Any complaints
about this test report should be communicated in writing within 7 Days of issue of this report.
Examined By Witnessed / Reviewed By For, Pallakki NDT Excellence Center Pvt. Ltd.
Shivakumar S Shashidhar P Pallakki Sowmya R. C

ASNT & ISNT Level III


PNEC/RT/F/03 This is Electronically generated Document, Authorised to consider without Seal. Page 1 of 1
*** END OF REPORT ***

You might also like