SEISMIC COEFFICIENT AS PER NBC 105:2020
Seismic Zoining Factor (Z)= 0.35
Importance Factor (I)= 1
Height of Building (h)= 6
Soil Type A
Period of Vibration:
For Reinforced Moment Resisting Frame Kt= 0.075
T1=1.25*Kt*h^0.75 (Sec) 0.359405
Lower Period of the Flat Part of the Spectrum Ta= 0
Upper Period of the Flat of the Spectrum Tc= 0.5
Peak Spectral Acceleration Normalized by PGAo= 2.5
Coefficient to control the descending branch of the Spectrum K= 1.8
Calculation of Spectral Shape Factor : Ch (T)
Since Ta<=T1<=Tc
Ch(T)= 2.5
Elastic Site Spectra for the Horizontal Loading ( Clause 4.1.1 NBC 105-2020)
C(T)=Ch(T)*Z*I= 0.875
Elastic Site Spectra for the SLS state ( Clause 4.2 NBC 105-2020)
Cs(T1)=0.2*C(T)= 0.175
Horizontal Base Shear Coefficient for Equivalent Static Method:
Ref Table 5.2 NBC 105:2020
Ductility Factor for ULS State (Ru)= 4
Overstrenght Factor for ULS State (Wu)= 1.5
Overstrenght Factor forSLS State (Ws)= 1.25
Horizontal Base Shear Coefficient at the ULS State
Cd(T1)=C(T)/(Ru*Wu)= 0.145833
Horizontal Base Shear Coefficient at the ULS State
Cd(T1)=Cs(T1)/*Ws= 0.14
Exponent related to the structural period (K)= 1
Displacement Criteria For Equivalent Static Method: ALONG X DIR.
Allowable ratio ULS 0.025 mm
Allowable Displacement ULS=0.025*H/Ru= 37.5 mm
Allowable ratio SLS 0.006 mm
Allowable Displacement SLS=0.006H/Rs= 36 mm
Drift Criteria For Equivalent Static Method: ALONG X DIR.
Storey Drift From ETABS ULS 0.025 OK
Allowable Drift ULS=0.025/Ru= 0.00625
Storey Drift From ETABS SLS 0.006 OK
Allowable Drift SLS=0.006/Rs= 0.006
Displacement Criteria For Equivalent Static Method: ALONG Y DIR.
Allowable ratio ULS 0.025 mm
Allowable Displacement ULS=0.025*H/Ru= 0 mm
Allowable ratio SLS 0.006 mm
Allowable Displacement SLS=0.006H/Rs= 0 mm
Drift Criteria For Equivalent Static Method: ALONG Y DIR.
Storey Drift From ETABS ULS 0.025 OK
Allowable Drift ULS=0.025/Ru= 0.025
Storey Drift From ETABS SLS 0.006 OK
Allowable Drift SLS=0.006/Rs= 0.006