Display TFT MARLIN – EVO
TFT EVO Ver 1.0
Pag. 1/8
MoviLift 29 May 2017
INTRODUCTION
MOVILIFT TFT display EVO is multi-parallel and serial in cabin to indicate number/stop, up/down direction
and service messages..
Number of floor range is from -9 to 31
FW Firmware DESCRIPTION
1.0 Start Version
1.1 “7 segments” mode added
Assembly
This display can be used in Horizontal or vertical by dedicated software named ATLANTIS EVO.
HORIZONTAL: 800x480 pixel. To can install correctly please check reading of words OK, UP and DOWN on
back side.
VERTICAL: 480x800 pixel. To Install correctly check CAN connector and POWER connector, they have to be
on LEFT side (backside view).
SERIAL Connection
Serial mode is by CANbus. It is connected to BRXXX board by CANbus. Connection is made by 4 wires (2 for
data + 2 power supply) by J1 and J2 connectors.
WARNING: power supply is provided by MOTHERBOARD , do not connect ALIM connector
If CANbus system is closed by TFT display it is necessary to move J1 to ON to can close ending resistor.
J1- J2 Connectors
Pin MEANING
1 CAN-L
2 GND
3 CAN-H
4 +12/24V
( pin 1 is indicated by copper square)
MULTI-PARALLEL Connection
TFT multi-parallel working uses digital input by P! and P2 connectors… next pages full description.
Use ALIM1 connector for power supply.
TFT EVO Ver 1.0
Pag. 2/8
MoviLift 29 May 2017
TECHINAL DATA
DIMENSION 7 inch
RESOLUTION 800 x 480 pixel
ORIENTATION Programmable Horizontal/Vertical
POWER SUPPLY 12-24 VDC ± 10%
CURRENT 250mA – xxx mA max.
CODING Serial or parallel
PROGRAMMING By buttons on board, by microSD card and PC Tool
WORKING TEMPERATURE -°C a +°C
LOUD SPEAKER 4-8Ω 1-5W to be connected to the SP1 connector
MESSAGES With a Micro SD Card, 4 Gb
AUDIO
MARLIN EVO TFT has a programmable voice synthetizer for the services messages and floor messages in 9
different languages. All the messages are available in a micro SD card, which needs to be always inserted
into its slot.
Background audio (like music or promo messages) , are memorized on the onto the micro SD card, in the
“BkGr” folder.
There can be more than one file in MP3 format. Maximu file number is 100. Files needs to renamed from
“00.wav” up to “99.wav” . they don’t need to be placed in a progressive manner.
Any operation like: add, modify, cancel of any file, can be performed easily with a normal PC , directly from
the user.
Do not remove the SD card when the indicator is on!
PROGRAMMING
There are 3 ways:
By button UP, DOWN, OK embedded on board
By PC Tool ATLANTIS
Programming by buttons
It allows to change only MAIN parameters:
StandBy, WORK MODE (Interface, Demo), Luminosity, Fatcory retsore, Offset first floor (in parallel mode)
To enter in MENU press OK
To move intomenu use UP and DOWN button
To confirm any value press OK
To not save the value wait 10 seconds without any action. ESC button does not exist.
TFT EVO Ver 1.0
Pag. 3/8
MoviLift 29 May 2017
Programming by Tool ATLANTIS
By Tools is possible to configure all parameter and also images. Tool gives file ‘TFT.INI’ and ‘TFTIMG.HEX’
that are necessary to put on SD card. When SD card is ready b(with two files inside), power OFF the display,
insert SD in TFT, power ON the display and wait LOADING MESSAGE and then power OFF again and remove
SD card.
PARALLEL CODE – BOARD INPUT
All input of P1 and P2 connectors are common positive. To activate an input is necessary provide a signal
Ground.
MAN Inspection
OOS OutOfService
FS UP Arrow
FD Down Arrow
SVR Overload
In table is showed the different meaning of inputs in according to working mode selected.
CONNECTOR P1
Pin 9 10 11 12/MAN 13/OOS 14/FS 15/FD 16/SVR
1 ppp 8 9 10 MAN OOS FS FD SVR
Binary MAN OOS FS FD SVR
Binary Neg. MAN OOS FS FD SVR
BCD MAN OOS FS FD SVR
GRAY MAN OOS FS FD SVR
CONNECTOR P2
Pin 1 2 3 4 5 6 7 8
1 ppp 0 1 2 3 4 5 6 7
Bin. A B C D E SIGN
Bin. Neg. A B C D E SIGN
BCD A B C D TEN SIGN
GRAY A B C D E SIGN
On Board there is also J5 connector, provided by 3 differential and independent inputs that gives further
signals:
AA+ AA- Activated Alarm
AR+ AR- Received Alarm
LE+ LE- Emergency Lamp
Emergency lamp
LE Input has priority on other signals. When it is activated display will be WHITE and Luminosity will be max.
TFT EVO Ver 1.0
Pag. 4/8
MoviLift 29 May 2017
WORKING MODE
Display can work in some MODE, in according to digital inputs programming:
WORKING Description
MODE
1 line/floor Each input is for each floor. If more inputs actived in same moment or any inputed activated
displsy show ‘ - - ‘‘
Binary Use only 5 inputs to calculate floor number in binary code (range from 0 to 31). Input 6 is
used for sign.
Binary Neg Use only first 5 input, denied logical, to calculate floor number in binary code (range from 0
to 31). Input 6, denied, is used for sign.
BCD Use first 4 input to calculate the unit digit in binary code and input 5 to calculate the ten
digit. Input 6 is for sign
GRAY Use only first 5 input to calculate floor number in GRAY code (range from 0 to 31). Input 6 is
for sign
Stand-alone Two magnetic N.O. sensors in the shaft, like appendix 1, the selector follows the car
sensors movements giving the right signal to the indicator for showing floor number and arrow.
Selector sensors IF and ICV must be wired to inputs number 1 and 2 of the pcb. Reset can
be performed having the two sensors at the lowest floor zone, this will allow an indicator
reset.
7 Segments 7 segments. Each input corresponds to a specific segment of the indicator digit.
CODING
Binary, binary NEg, BCD and GRAY use only first 5 inputs to calculate number of floor, from 0 to 31. The
table shows the value in according to working mode.
Input 1, named A, is less significative. Input 5, named E, is more significative. Naturally is possible use few
input when floor number is lower than 32.
OFF: input not active (input open) - ON: input active (input close)
INPUT
5/E 4/D 3/C 2/B 1/A BINARY BINARY GRAY BCD
NEG
OFF OFF OFF OFF OFF 0 31 0 0
OFF OFF OFF OFF ON 1 30 1 1
OFF OFF OFF ON OFF 2 29 3 2
OFF OFF OFF ON ON 3 28 2 3
OFF OFF ON OFF OFF 4 27 7 4
OFF OFF ON OFF ON 5 26 6 5
OFF OFF ON ON OFF 6 25 4 6
OFF OFF ON ON ON 7 24 5 7
OFF ON OFF OFF OFF 8 23 15 8
OFF ON OFF OFF ON 9 22 14 9
OFF ON OFF ON OFF 10 21 12 --
OFF ON OFF ON ON 11 20 13 --
OFF ON ON OFF OFF 12 19 8 --
OFF ON ON OFF ON 13 18 9 --
OFF ON ON ON OFF 14 17 11 --
OFF ON ON ON ON 15 16 10 --
ON OFF OFF OFF OFF 16 15 -- 10
TFT EVO Ver 1.0
Pag. 5/8
MoviLift 29 May 2017
ON OFF OFF OFF ON 17 14 -- 11
ON OFF OFF ON OFF 18 13 -- 12
ON OFF OFF ON ON 19 12 -- 13
ON OFF ON OFF OFF 20 11 -- 15
ON OFF ON OFF ON 21 10 -- 15
ON OFF ON ON OFF 22 9 -- 16
ON OFF ON ON ON 23 8 -- 17
ON ON OFF OFF OFF 24 7 16 18
ON ON OFF OFF ON 25 6 17 19
ON ON OFF ON OFF 26 5 19 --
ON ON OFF ON ON 27 4 18 --
ON ON ON OFF OFF 28 3 -- --
ON ON ON OFF ON 29 2 22 --
ON ON ON ON OFF 30 1 20 --
ON ON ON ON ON 31 0 21 --
Signal Priority
In case of more events in the same moment, there are priority on visualization: Received Alarm ->
Activated alarm-> Inspection -> Out of service -> Overload
In case UP and DOWN arrow ON in same moment they will be both OFF.
DIAGNOSTIC
Board has green LED named RDY and red LED named ERR to support the user during diagnostic and
programming steps.
LED RDY
OFF Error showed by LED ERR
Short flash: one per second Board operative in normal mode
Long flash: one per second Board Operative in Programming or DEMO mode
LED ERR
OFF NO error
1 flash and 1 sec pause Auto test error
2 flash and 1 sec pause Missed reception of CAN signal for more than 5 sec.
3 flash and 1 sec pause Can bus transmission error
4 flash and 1 sec pause EEPREOM parameters reading Error
5 flash and 1 sec pause EEPREOM parameters writing Error
FIRMWARE UPDATES
It is possible to update firmware in this way:
- Put file ‘TFTPROG.HEX’ in the MAIN route of MicroSD
- Insert SD into TFT when it id POWER OFF
- HOLD push button OK and power ON the display
- Check messages showed, then POWER OFF the display and remove SD.
Il file per l’aggiornamento viene ovviamente fornito dalla MoviLift, per esempio via email.
TFT EVO Ver 1.0
Pag. 6/8
MoviLift 29 May 2017
Appendix 1: ATLANTIS EVO - PC tool
This tool allows to configure completely TFT in very simple way. When configuration completed it is
necessary to save both generated file on microSD (‘TFT.INI’ and ‘TFTIMG.HEX’) and load both on display
TFT.
It is possible to modify:
Interface Typology (serial/parallel)
Working Mode PARALLEL (1line/floor, binary, etc.)
Brightness
Normal/demo MODE
Background (Image or color)
Text “numero di matricola”
Text “numero dell’impianto”
Text “portata”
Text “numero di persone”
Note (3 rows)
It is possible to modify for each scene:
Font of number of floor (3 different fonts)
Type of Arrow (3 different type)
Background (Fixed Image or fixed color)
Image and position of LOGO
Image and Position CE mark
Image and position NO SMOKE
Position Registration Number
Position Lift Number
Position Capacity
Position Note
TFT EVO Ver 1.0
Pag. 7/8
MoviLift 29 May 2017
FIG 1. Magnets location in the shaft for stand alone system
TFT EVO Ver 1.0
Pag. 8/8
MoviLift 29 May 2017