0% found this document useful (0 votes)
66 views3 pages

TeSys F Contactor LC1F1504 Specs

1. This document provides product data for a TeSys F contactor with 4 NO poles rated for 250A at 440V AC-1. 2. It has a control circuit voltage of 24-575V AC or 24-460V DC and is intended for resistive loads in an overvoltage category III environment. 3. The contactor has terminals for power and control circuit wiring and meets various industry standards for safety and performance.

Uploaded by

ramiz raza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views3 pages

TeSys F Contactor LC1F1504 Specs

1. This document provides product data for a TeSys F contactor with 4 NO poles rated for 250A at 440V AC-1. 2. It has a control circuit voltage of 24-575V AC or 24-460V DC and is intended for resistive loads in an overvoltage category III environment. 3. The contactor has terminals for power and control circuit wiring and meets various industry standards for safety and performance.

Uploaded by

ramiz raza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Product data sheet LC1F1504

Characteristics TeSys F contactor - 4P(4 NO)-AC-1 <= 440V


250A with coil LX9 - 24...575V AC 40/400Hz,
LX4 - 24...460V DC, LXE - 100...250V AC
50/60Hz or 100…380V DC

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range TeSys
Product name TeSys F
Product or component type Contactor

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Device short name LC1F

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Contactor application Resistive load
Utilisation category AC-1
Poles description 4P
Pole contact composition 4 NO
[Ue] rated operational voltage <= 690 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 250 A (at <40 °C) at <= 440 V AC-1

Complementary
[Uc] control circuit voltage 24...575 V AC 40...400 Hz with LX1/LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage 8 KV
Overvoltage category III
[Ith] conventional free air thermal current 250 A (at 40 °C)
Irms rated making capacity 1500 A conforming to IEC 60947-4-1
Rated breaking capacity 1200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 1200 A 40 °C - 10 s
700 A 40 °C - 30 s
600 A 40 °C - 1 min
450 A 40 °C - 3 min
350 A 40 °C - 10 min
Associated fuse rating 250 A gG at <= 440 V
Average impedance 0.35 MOhm - Ith 250 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole 22 W AC-1

Oct 9, 2021
1
Control circuit voltage limits Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.15...0.2 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
Heat dissipation 5.9…7.2 W
2.2…2.5 W
Operating time 35 ms closing for with LX1/LX9 coil
130 ms opening for with LX1/LX9 coil
30...40 ms closing for with LX4 coil
30...50 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
Mounting support Plate
Standards EN 60947-1
JIS C8201-4-1
IEC 60947-1
IEC 60947-4-1
EN 60947-4-1
Product certifications ABS
CSA
BV
CB
RINA
RMRoS
DNV
LROS (Lloyds register of shipping)
UL
UKCA
Connections - terminals Power circuit: lugs-ring terminals 1 cable(s) 120 mm² - busbar cross sec-
tion: 25 x 3 mm
Power circuit: connector 1 cable(s) 120 mm²
Power circuit: bar 2 cable(s)
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without ca-
ble end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without ca-
ble end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without-
cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with ca-
ble end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without ca-
ble end
Tightening torque Power circuit: 18 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
Mechanical durability 10 Mcycles
Inrush power in VA 690…855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
543…665 VA (at 20 °C)with LX4 coil
280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
270…320 VA (at 20 °C)with LXE coil
Hold-in power consumption in VA 6.6…8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
3.94…4.83 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
Maximum operating rate 2400 Cyc/H 55 °C
Compatibility code LC1F

2
Environment
IP degree of protection IP2x front face with shrouds conforming to IEC 60529
IP2x front face with shrouds conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -40…60 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the de- 60…70 °C at Uc
vice
Operating altitude 3000 m without derating
Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 6 Gn, 5...300 Hz
Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height 170 Mm
Width 200.5 Mm
Depth 171 Mm
Product weight 3.83 Kg

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 4.27 Kg
Package 1 Height 22 Cm
Package 1 width 20 Cm
Package 1 Length 27 Cm
Unit Type of Package 2 P06
Number of Units in Package 2 18
Package 2 Weight 86.008 Kg
Package 2 Height 77 Cm
Package 2 width 60 Cm
Package 2 Length 80 Cm

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and-
lead compounds, which is known to the State of California to cause can-
cer and birth defects or other reproductive harm. For more information go-
to www.P65Warnings.ca.gov

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised