General Model SC4A Conductivity

Specifications Sensors and Fittings


for 2-electrode Systems
GS 12D07J04-01EN-P

The measurement of specific conductivity in aqueous solutions is becoming


increasingly important for the determination of impurities in water. The accuracy
of the measurement is strongly influenced by temperature variations, polarization
effects at the surface of the contacting electrodes, cable capacitances, etc. Yokogawa
has designed a full range of precision sensors and instruments to cope with these
measurements, even under extreme conditions.
The SC4A sensors are intended for the low conductivity applications found in the
semi-conductor, power, water and pharmaceutical industries; these sensors are in a
convenient compact style. There are several mounting possibilities one of which is
mounting by a compression gland, giving a simple effective method of direct insertion
in process pipework.The sensors are made from a combination of wetted materials
approved by FDA. This makes them ideally suited for the monitoring of pure water
systems used in the preparation of injectable solutions and the like, for this kind of
application, sanitary clamp mountings are used.
Model SC4A sensors, available in a Stainless Steel or Titanium version with fixed
cable or Variopin connector, in combination with WU10/WE10-cable are intended
for the low conductivity applications. These sensors are designed in a convenient
compact style and can be inserted directly in process pipework using available fittings
or adapters. There are several mounting possibilities, including a compression gland,
giving a simple effective method of direct insertion in process pipework.The sensors
are made from a combination of wetted materials approved by FDA. This makes them
ideally suited for the monitoring of pure water systems used in the preparation of
injectable solutions. For this kind of application, sanitary clamp mountings are most
often used.
All sensors have a pre-calibrated cell constant and a built-in temperature element
for automatic temperature compensation. Sensors with the Variopin connector are
equipped with an ID-chip in which calibration information is stored for easy setup when
connected to a SENCOM Smart Adapter model SA11-C1. The Variopin connector can
also be used without the SA11-C1 adapter. Not using the SA11 will not give you the
benefits of digital sensor use. For metal sensors, a 3.1 material certificate is included.
The sensors are certified for hazardous area when connected to a certified intrinsically
safe Yokogawa analyzer, model SC202S or FLXA-series or a certified intrinsically safe
circuit with defined output parameters.

FEATURES
• Compact style sensor
• Built-in temperature resistor: Pt1000
• Fast temperature response
• Plug and cable form a water tight connection to IP67
• Selection of two cell constant 0.02 cm-1 or 0.10 cm-1
• Sensor with 8 pin Variopin with ID chip for SENCOM SA11-C1 use
• Certified for hazardous area
• Direct process insertion
• Wide range of mountings
• Compatible with PR10 retractable assembly
• The sensor is polished to meet pharmaceutical requirements
• Standard quality inspection certificate with delivery of sensor
• Peek and O-rings according to FDA standard

System Configuration

Sensors Cables Fittings Transmitters Accessories

GS 12D07J04-01EN-P
2nd Edition November, 2021
2
1. SPECIFICATIONS
General Specifications

1.1 Measuring method : 2-electrode

1.2 Measuring element : Pt1000 temperature sensor

1.3 Wetted parts


Sensor Body and electrodes : SC4A-T-AD : Titanium grade 2 or 3
SC4A-S-AD Stainless Steel AISI 316L
SC4A-E-SA (SB, SC) Stainless Steel AISI 316L
SC4A-T-PR Titanium grade 2 or 3
SC4A-S-PR Stainless Steel AISI 316L

O-ring : SC4A-*-AD : Viton


SC4A-E-SA (SB, SC) EPDM FDA approved
SC4A-*-PR Viton

Insulation : All models : PEEK 450G, FDA migration tested

Connector Variopin : Contacts : gold plated


Material Nickel-plated brass
Insulation PEEK, UL94-V0

Wetted parts adapters/fitting : /PS, /FF for SC4A-*-AD : Stainless Steel AISI 316L
/PF for SC4A-*-AD PVDF
/SA1(2), /SB1(2), /SC1 for
SC4A-E-SA (SB, SC) Stainless Steel AISI 316L

Cable1 : Conductors : tinned copper 0.6 mm2


Outside shield braid, tinned copper, 85% coverage
Insulator Polyester for conductor*

* for colors see Section 5.1, TPE-O for outer jacket, color black
Note 1 : Cable is not considered as wetted part

1.4 Functional specifications (at 25 °C)


Temperature element2 : Pt1000 to IEC 751
Nominal Cell Constant : 0.02 cm-1 or 0.01 cm-1

Note 2: The temperature sensor included in the sensor is designed for process compensation and for indication.
It is NOT designed for process temperature control.

1.5 Dynamic specifications


Response time temperature (t90) : < 1 min.

1.6 Operating range


Conductivity range* at actual process temperature : 1 μS x C.C. – 200 mS x C.C. (See Fig. 1)

* measurement range dependent on input range analyzer.

GS 12D07J04-01EN-P
3

Figure 1. Measuring range of conductivity sensors section

Temperature @ 100 KPa : 0 °C ... 125 °C (32 °F to 257 °F) - For VarioPin type sensors
(1 Bar, 14.5 PSI) 0 °C ... 100 °C (32 °F to 212 °F) - For fixed cable type sensors

Remark:
For all types 135°C (275 °F) max. for a short period of time during sterilization.
In combination with a fitting or option, the specification of the most critical part is leading.

Pressure @ 25 °C : Stainless Steel & Titanium type


Over pressure 0 to 10 barg (7 to 142 PSIG)*
Under pressure 0 to 0.5 barng (0 to 7 PSIG)*

* Unit definition: barg = bar gauge, over pressure against atmosphere.


barng = under pressure against atmosphere

Process Pressure in combination with PVDF fitting: (See Fig. 2)

Figure 2. Process pressure in combination with fitting

GS 12D07J04-01EN-P
4
1.7 Shipping details
Package size (LxWxH) : 220 x 220 x 90 mm (8.7 x 8.7 x 3.6 inch) - Fixed cable version
300 x 100 x 75 mm (11.8 x 3.9 x 3.0 inch) - VarioPin type version

Package weight (max.) SC4A-*** connection type: -03/VS -05 -10 -15 -20
0.63 0.78 1.13 1.48 1.83 kg
1.4 1.7 2.5 3.0 4.0 lbs

1.8 Environmental conditions


Storage temperature : -30 ºC to +50 ºC (-22 ºF to +122 ºF)
Ingress Protection fixed cable type : IP65 (conform IEC 60529)
Ingress Protection VarioPin type : IP67 (conform IEC 60529)

1.9 Mechanical specifications


Surface roughness SC4A-*-AD : max. 0.8 μm
SC4A-E-SA/SB/SC : max. 0.5 μm
SC4A-*-PR : max. 0.8 μm

1.10 Regulatory compliances:

Item Description, Approval, Certification


ANSI/ISA 61010-1
LVD
CAN/CSA C22.2 No. 61010-1
EU Directive 2011/65/EU and Commission Delegated Directive (EU) 2015/863 amending Annex II, per
RoHS
EN-IEC 63000
PED EU Directive 2011/68/EU applying Article 4.3: Sound Engineering Practice.
EU directive 2012/19/EU
This sensor is intended to be sold and used only as a part of equipment which is excluded from the
WEEE directive, such as large-scale stationary industrial tools, a large-scale fixed installation etc., and
WEEE
therefore it is in principle fully compliant with WEEE directive.
The sensor should be disposed in accordance with applicable national legislations/regulations
respectively.
EU Directive 2014/34/EU
ATEX approval: DEKRA 14ATEX0074 X 0344
SC4A: II 1 G Ex ia IIC T4…T6 Ga
ATEX (EU)
SC42: II 1 G Ex ia IIC T3…T6 Ga
SX42: II 1 G Ex ia IIC T2…T6 Ga
Applied standards: EN IEC 60079-0, EN 60079-11
IECEx approval: IECEx DEK 14.0032X
SC4A: Ex ia IIC T4…T6 Ga
IECEx SC42: Ex ia IIC T3…T6 Ga
SX42: Ex ia IIC T2…T6 Ga
Applied standards: IEC 60079-0, IEC 60079-11
FM approval Canada: FM20CA0062X
SC4A: IS SI CL I, DIV 1, GP ABCD, T4…T6; CL I, ZN 0, Ex ia IIC, T4…T6 Ga
SC42: IS SI CL I, DIV 1, GP ABCD, T3…T6; CL I, ZN 0, Ex ia IIC, T3…T6 Ga
FM (Canada) SX42: IS SI CL I, DIV 1, GP ABCD, T2…T6; CL I, ZN 0, Ex ia IIC, T2…T6 Ga
Control Drawing: D&E 2020-024-A51
Applied standards: CAN/CSA-C22.2 No. 60079-0, CAN/CSA-C22.2 No. 60079-11,
CAN/CSA-C22.2 No. 61010-1
FM approval United States: FM20US0123X
SC4A: IS CL I, DIV 1, GP ABCD, T4…T6; CL I, ZN 0, AEx ia IIC, T4…T6 Ga
SC42: IS CL I, DIV 1, GP ABCD, T3…T6; CL I, ZN 0, AEx ia IIC, T3…T6 Ga
FM (United States) SX42: IS CL I, DIV 1, GP ABCD, T2…T6; CL I, ZN 0, AEx ia IIC, T2…T6 Ga
Control Drawing: D&E 2020-024-A50
Applied standards: FM Class 3600, FM Class 3610, ANSI/ISA 60079-0, ANSI/ISA 60079-11,
ANSI/ISA 61010-1
NEPSI approval: GYJ21.2892X
SC4A: Ex ia IIC T4…T6 Ga
NEPSI (China) SC42: Ex ia IIC T3…T6 Ga
SX42: Ex ia IIC T2…T6 Ga
Applied standards: GB 3836.1, GB 3836.4, GB 3836.20

GS 12D07J04-01EN-P
5
1.10 Regulatory compliances:

Item Description, Approval, Certification


PESO approval: PESO approval is based on ATEX approval
DEKRA 141ATEX0074 X, iss. 2 – 29.11.2019
PESO (India)
Equipment reference numbers: P512759/1
Applied standards: EN IEC 60079-0, EN 60079-11
TS approval: TS Safety Label is based on IECEx approval IECEx DEK 14.0032X
TS (Taiwan) Identification Number: TD04000C
Applied standards: IEC 60079-0, IEC 60079-11
EAC Ex certificate: RU C-NL.AA87.B.00754
SC4A: 0Ex ia IIC T6…T4 Ga X
SC42: 0Ex ia IIC T6…T3 Ga X
EAC Ex (Russia)
SX42: 0Ex ia IIC T6…T2 Ga X
Applied standards: GOST 31610.0 (IEC 60079-0), GOST 31610.11 (IEC 60079-11),
GOST IEC 60079-14

GS 12D07J04-01EN-P
6
2. SPECIFICATIONS SC4A-AD Dimensions SC4A-AD
General Specifications

2.1 Materials Wetted Parts


Body & electrodes : Stainless steel AISI 316L or
Titanium grade 2 or 3
O-ring : Viton
Mounting adapter : PVDF or Stainless steel AISI 316L
Insulation : PEEK (Polyether Ether Ketone)
FDA migration tested CFR

90 (3.55")
177 .2415 FDA migration tested 21
CFR 177.2415 +, PIM and

152 (5.98")

152 (5.98")
USP class VI
Surface Roughness : 0.8µm (R432)

Ø 19,1

2.2 Operating Specifications (Sensor) (0.75")

See paragraph 1.6 * units in mm (inch)

Figure 3. SC4A-AD-15 / SC4A-AD-09


2.3 Model and Suffix codes
Model SC4A-AD

Model Suffix Code Option Description


code

SC4A 19 mm conductivity sensor


Material -T Titanium Grade 2 or 3
-S Stainless steel AISI 316L (SS
Fitting- -AD For adapter mounting
type
Sensor- -09 9 cm 1)
length
-15 15 cm
Cell constant -002 0.02/cm
-010 0.1/cm
Connection type -03 Fixed cable with wirepins, 3 m
-05 Fixed cable with wirepins, 5 m
-10 Fixed cable with wirepins, 10 m
-15 Fixed cable with wirepins, 15 m
-20 Fixed cable with wirepins, 20 m
-VS No Cable; Variopin connector with SENCOM ID-chip
Temperature element -T1 Pt1000, IS for ATEX/IECEx/FM-US/FM-CAN
/PS 3/4” stainless steel adapter
/PF 3/4” PVDF adapter
Units: mm [inches]
/FF Flow fitting stainless steel AISI 316L 2)

1)
2)
Suffix -AD-09 not available with -VS.
With option /FF: option /PS is mandatory.
Figure 4. - Mounted sensor with the option /
PF and /PS

2.4 Spare parts SC4A-AD


Adapters SC4A-*-AD sensor
Part no. Description Process conn. Material Quantity
K1542DF /PS 3/4” NPT adapter Stainless Steel 1

K1542CW /PF 3/4” NPT adapter PVDF 1

K1598AC /FF Flow fitting Stainless Steel


Note 1 : For /FF is needed to have /PSz or PF.

GS 12D07J04-01EN-P
7

3/4 “NPT

1/4 “NPT

100 (3.94”)
1/4 “NPT
30(1.18”)

Units: mm [inches] * units in mm (inch)

Figure 5.1. Dimensional drawing /FF with the Figure 5. Dimensional drawing /FF with the
option /PS option /PS

GS 12D07J04-01EN-P
8
3. SPECIFICATIONS SC4A-SA/SB/SC Dimensions SC4A-SA
General Specifications

The SC4A-E is a conductivity sensor made of below materials


with full traceability and supporting documents.
• EPDM O-ring (21 CFR 177.2600)
• SS is 1.4435
• Double O-ring construction (EPDM 21 CFR 177.2450)
• Virgin PEEK isolator (21 CFR 177.2415) Ø 38 x 5
(1.50 x 0.20)
• Surface roughness Ra < 0.5µm (R416)
• Tested for sterilizability against EHEDG procedure 25
(1.00”) 19.8

• 5% accuracy for the Cell constant

95 (3.74")
Ø 25

95 (3.74")
(1.00")
Ø 24.9
3.1 Materials Wetted Parts
Body & electrodes : Stainless steel AISI 316L (1.4435)
O-ring : EPDM, FDA migration tested Ø 19.1
21 CFR 177.2600
Mounting adapter : Stainless steel AISI 316L Tri-clamp * units in mm (inch)

according to ISO 2852-1993 Figure 6. Sensor SC4A-SA


Insulation :PEEK (Polyether Ether Ketone)
FDA migration tested 21 CFR Dimensions SC4A-SB/SC Cable type
177.2415 + FDA, PIM European
Directive 10/2011/EC 1935/2004
and USP class VI
Surface Roughness : 0.5µm

3.2 Operating Specifications (Sensor)


(See paragraph 1.6) 2"
tri-clamp
1 - 1.5 "
tri-clamp

3.3 Model and Suffix codes Ø63,9


(2.52")
Ø50,4
(1.98")
Model Suffix Code Option Description
code Ø25
80 (3.15")

(1.00")
70 (2.75")

SC4A 19 mm conductivity sensor Ø19


(0.75")
Material -E Stainless steel AISI 316L (SS) with EPDM FDA
sealing
Fitting- -SA 25 mm port, for sanitary purposes
type
-SB 1-1½” tri-clamp
-SC 2” tri-clamp
* units in mm (inch)
Cell constant -002 0.02/cm
-010 0.1/cm Figure 7. Sensor SC4A-SB/SC
Connection type -03 Fixed cable with wirepins, 3 m
-05 Fixed cable with wirepins, 5 m
Dimensions SC4A-SB/SC Variopin type
-10 Fixed cable with wirepins, 10 m
-15 Fixed cable with wirepins, 15 m
-20 Fixed cable with wirepins, 20 m
-VS No Cable; Variopin connector with SENCOM ID-chip
Temperature element -T1 Pt1000, IS for ATEX/IECEx/FM-US/FM-CAN
/PS 3/4” stainless steel adapter
/PF 3/4” PVDF adapter
/FF Flow fitting stainless steel AISI 316L 1)
1)
With option /FF: option /PS is mandatory. 2"
tri-clover 1" - 11/2"
Ø 64 tri-clover

Ø 50.5
Ø 25
80

70

Ø 19.1 Ø 19.1

* units in mm (inch)

Figure 8. Sensor SC4A-SB/SC - VS Type

GS 12D07J04-01EN-P
9
3.4 Installation SC4A-SA/SB/SC

Units: mm [inches] Units: mm [inches]

Figure 9. Mounted Sensor SC4A -SA Figure 10. Mounting example

3.5 Adapters SC4A-E-SA sensor


Part number Description Max Temp Max pressure Process connection Material Quantity
K1542FA /SA1 135°C 10 bar(142 PSGI) Straight welding socket Stainless steel 1
K1542FB /SA2 135°C 10 bar(142 PSGI) Angled welding socket Stainless steel 1

3.6 Spare parts for adapters SC4A-E-SA sensor


Part number Description Quantity
K1520EJ Straight weld-in adapter without mounting nut, Stainless Steel 1
K1520EK Angled weld-in adapter without mounting nut, Stainless Steel 1

3.7 Spare parts for SC4A-E-SA sensor


Part number Description Quantity
K1542DL O-ring set, EPDM FDA, 20.3 x 2.62 3
K1542DK O-ring set, Viton, 20.3 x 2.62 3

3.8 Adapters SC4A-E-SA sensor


Part number Description Max Temp Max pressure Process connection Material Quantity
K1542FC /SB1 135°C 10 bar(142 PSGI) Tri-clamp 1” Stainless steel 1
K1542FF /SB2 135°C 10 bar(142 PSGI) Tri-clamp 1½“ Stainless steel 1

3.9 Spare parts for SC4A-E-SA sensor


Part number Description Quantity
K1500BN Clamp seal ring, EPDM FDA, 1” ~ 1½“ 1
K1542DG Clamp seal ring, Viton, 1“ 3
K1542DH Clamp seal ring, Viton, 1½“ 3

3.10 Adapters SC4A-E-SA sensor


Part number Description Max Temp Max pressure Process connection Material Quantity
K1542FE /SC1 135°C 10 bar(142 PSGI) Tri-clamp 2” Stainless steel 1

3.11 Spare parts for SC4A-E-SA sensor


Part number Description Quantity
K1500BP Clamp seal ring, EPDM FDA, 2“ 1
K1542DJ Clamp seal ring, Viton, 2“ 3

GS 12D07J04-01EN-P
10
4. SPECIFICATIONS SC4A-PR
General Specifications
Dimensions SC4A-PR
4.1 Materials Wetted Parts
Body & electrodes : Stainless steel AISI 316L
or Titanium grade 2 or 3
O-ring : Viton
Mounting adapter : Retractable fitting
Insulation :PEEK (Polyether Ether Ketone)

M19x1.5
4.2 Operating Specifications (Sensor)
See paragraph 1.6

4.3 Installation SC4A-*-PR


The installation of the SC4A-*-PR sensor is done using the Ø 27.5
Model PR10 retractable fitting. The mounting procedure of

48 (1.89")

52 (2.04)
(1.08)

41 (1.6)
the sensor is explained in the Instruction Manual of this fitting.

Ø 19.1
Part no. Description Quantity (0.75)
* units in mm (inch)
K1500BE O-ring set, Viton, 15.6 x 1.78 10
K1500ED O-ring set, Kalrez, 15.6 x 1.78 1 Figure 11. SC4A -PR

4.4 Model and Suffix codes

Model Suffix Code Option Description


code

SC4A 19 mm conductivity sensor


Material -T Titanium Grade 2 or 3
-S Stainless steel AISI 316L (SS)
Fitting- -PR For retractable mounting
type
Sensor- -NN Fixed length
length
Cell constant -002 0.02/cm
-010 0.1/cm
Connection type -03 Fixed cable with wirepins, 3 m
-05 Fixed cable with wirepins, 5 m
-10 Fixed cable with wirepins, 10 m
-15 Fixed cable with wirepins, 15 m
-20 Fixed cable with wirepins, 20 m
-VS No Cable; Variopin connector with SENCOM ID-chip
Temperature element -T1 Pt1000, IS for ATEX/IECEx/FM-US/FM-CAN

GS 12D07J04-01EN-P
11
5. ADDENDUM 1: Typical Installations

For optimum measurement results, the SC4A sensor should be installed in a location that offers an acceptable representation of the
process composition and DOES NOT exceed the specifications of the sensor.

5.1 Typical installation SC4A-*-AD with standard options


The SC4A-*-AD sensor can be installed in the process using optional ¾” NPT adapters. These adapters are available in Stainless Steel
(/PS) and in PVDF (/PF); see Figure 12 for the mounting sequence. The sensor can also be installed in an optional Stainless-Steel flow
fitting (/FF) using option /PS, see Figure 13 for details.

Units: mm [inches] Units: mm [inches]

Figure 12. Mounted sensor with option /PF and /PS Figure 13. Dimensional drawing /FF with
option /PS

5.2 Typical installation SC4A-E-SA (SB, SC) with standard options / spare parts
The typical installation of the SC4A-E-SA sensor is done by using a standardized 25 mm port. Stainless Steel welding sockets are
available as straight version (spare part /SA1) or 15° angled version (spare part /SA2). Both versions are delivered with mounting nut.
In Figure 14 an example is shown how to install the sensor using spare part /SA1. Sensors SC4A-E-SB and SC4A-E-SC are installed
by tri-clamp method, see Figure 15. For the SB version two Stainless Steel tri-clamps are available, in a 1” size (spare part /SB1) or in a
1½“ size (spare part /SB2). The SC version has just one Stainless Steel tri-clamp in a 2” size (spare part /SC1).

/SA1
51 (2.00")
55 (2.16")

* units in mm (inch) Units: mm [inches]

Figure 14. Mounted SC4A-E-SA sensor with Figure 15. Mounted SC4A-E-SB(-SC) sensor
spare part/ SA1

GS 12D07J04-01EN-P
12
5.3 Typical installation SC4A-*-PR
The installation of the SC4A-*-PR sensor is done using the Model PR10 retractable fitting.

Figure 16. Dimensional drawing PR10...-D32 Figure 17. Dimensional drawing PR10...-D50
with mounted SC4A sensor with mounted SC4A sensor

GS 12D07J04-01EN-P
13
6. ADDENDUM 2: Available model codes

SC4A-S-AD-09-002-03-T1 SC4A-T-AD-09-002-03-T1 SC4A-E-SB-NN-002-03-T1 SC4A-T-AD-15-002-VS-T1


SC4A-S-AD-09-002-05-T1 SC4A-T-AD-09-002-05-T1 SC4A-E-SB-NN-002-05-T1 SC4A-T-AD-15-010-VS-T1
SC4A-S-AD-09-002-10-T1 SC4A-T-AD-09-002-10-T1 SC4A-E-SB-NN-002-10-T1
SC4A-S-AD-09-002-15-T1 SC4A-T-AD-09-002-15-T1 SC4A-E-SB-NN-002-15-T1 SC4A-S-AD-15-002-VS-T1
SC4A-S-AD-09-002-20-T1 SC4A-T-AD-09-002-20-T1 SC4A-E-SB-NN-002-20-T1 SC4A-S-AD-15-010-VS-T1
SC4A-S-AD-09-010-03-T1 SC4A-T-AD-09-010-03-T1 SC4A-E-SB-NN-010-03-T1
SC4A-S-AD-09-010-05-T1 SC4A-T-AD-09-010-05-T1 SC4A-E-SB-NN-010-05-T1 SC4A-E-SC-NN-002-VS-T1
SC4A-S-AD-09-010-10-T1 SC4A-T-AD-09-010-10-T1 SC4A-E-SB-NN-010-10-T1 SC4A-E-SC-NN-010-VS-T1
SC4A-S-AD-09-010-15-T1 SC4A-T-AD-09-010-15-T1 SC4A-E-SB-NN-010-15-T1
SC4A-S-AD-09-010-20-T1 SC4A-T-AD-09-010-20-T1 SC4A-E-SB-NN-010-20-T1 SC4A-E-SB-NN-002-VS-T1
SC4A-E-SB-NN-010-VS-T1
SC4A-S-AD-15-002-03-T1 SC4A-S-PR-NN-002-03-T1 SC4A-E-SC-NN-002-03-T1
SC4A-S-AD-15-002-05-T1 SC4A-S-PR-NN-002-05-T1 SC4A-E-SC-NN-002-05-T1 SC4A-E-SA-NN-002-VS-T1
SC4A-S-AD-15-002-10-T1 SC4A-S-PR-NN-002-10-T1 SC4A-E-SC-NN-002-10-T1 SC4A-E-SA-NN-010-VS-T1
SC4A-S-AD-15-002-15-T1 SC4A-S-PR-NN-002-15-T1 SC4A-E-SC-NN-002-15-T1
SC4A-S-AD-15-002-20-T1 SC4A-S-PR-NN-002-20-T1 SC4A-E-SC-NN-002-20-T1 SC4A-T-PR-NN-002-VS-T1
SC4A-S-AD-15-010-03-T1 SC4A-S-PR-NN-010-03-T1 SC4A-E-SC-NN-010-03-T1 SC4A-T-PR-NN-010-VS-T1
SC4A-S-AD-15-010-05-T1 SC4A-S-PR-NN-010-05-T1 SC4A-E-SC-NN-010-05-T1
SC4A-S-AD-15-010-10-T1 SC4A-S-PR-NN-010-10-T1 SC4A-E-SC-NN-010-10-T1 SC4A-S-PR-NN-002-VS-T1
SC4A-S-AD-15-010-15-T1 SC4A-S-PR-NN-010-15-T1 SC4A-E-SC-NN-010-15-T1 SC4A-S-PR-NN-010-VS-T1
SC4A-S-AD-15-010-20-T1 SC4A-S-PR-NN-010-20-T1 SC4A-E-SC-NN-010-20-T1

SC4A-T-AD-15-002-03-T1 SC4A-E-SA-NN-002-03-T1 SC4A-T-PR-NN-002-03-T1


SC4A-T-AD-15-002-05-T1 SC4A-E-SA-NN-002-05-T1 SC4A-T-PR-NN-002-05-T1
SC4A-T-AD-15-002-10-T1 SC4A-E-SA-NN-002-10-T1 SC4A-T-PR-NN-002-10-T1
SC4A-T-AD-15-002-15-T1 SC4A-E-SA-NN-002-15-T1 SC4A-T-PR-NN-002-15-T1
SC4A-T-AD-15-002-20-T1 SC4A-E-SA-NN-002-20-T1 SC4A-T-PR-NN-002-20-T1
SC4A-T-AD-15-010-03-T1 SC4A-E-SA-NN-010-03-T1 SC4A-T-PR-NN-010-03-T1
SC4A-T-AD-15-010-05-T1 SC4A-E-SA-NN-010-05-T1 SC4A-T-PR-NN-010-05-T1
SC4A-T-AD-15-010-10-T1 SC4A-E-SA-NN-010-10-T1 SC4A-T-PR-NN-010-10-T1
SC4A-T-AD-15-010-15-T1 SC4A-E-SA-NN-010-15-T1 SC4A-T-PR-NN-010-15-T1
SC4A-T-AD-15-010-20-T1 SC4A-E-SA-NN-010-20-T1 SC4A-T-PR-NN-010-20-T1

GS 12D07J04-01EN-P
14
7. ADDENDUM 3: Control drawings
7.10 FM-United States
Applying standards : FM Class 3600
FM Class 3610
FM Class 3810
ANSI/ISA 60079-0
ANSI/ISA 60079-11
Certificate no.* : FM20US0123X
IS CL I, DIV 1, GP ABCD, T4…T6 CL I, ZN 0, AEx ia IIC, T4…T6 Ga
Control Drawing: D&E 2020-024-A50
Electrical data : (See Note)
Specific conditions of use : See Control Drawing D&E 2020-024-A50.
Temperature classes for SC4A models are defined T4…T6 (See Note).

Note: Intrinsically safe, entity, for Class I, Division 1, Groups A, B, C and D; Class I, Zone 0, AEx ia IIC, Ga (entity) for
hazardous (classified) locations when installed per control drawing D&E 2020-024-A50.
Maximum sensor input parameters:
Ui= 14.4 V; Ii= 116.5 mA; Pi= 0.3424 W
Li= 0.1 mH (models with fixed cable) or Li= 0 mH (VS type)
Ci= 150 nF (models with fixed cable) or Ci= 0.4 nF (VS type)
Ambient temperature:
-30°C to +40°C for temperature class T6,
-30°C to +95°C for temperature class T5,
-30°C to +125°C for temperature class T4 (VS type),
-30°C to +130°C for temperature class T4 (models with fixed cable).

When the sensor has been connected to non intrinsically safe


equipment which exceeds the restrictions regarding the sensor input
circuits, the sensor is not suitable anymore for intrinsically safe use.

* Certification is subject to change, due to new regulations or changes in the product itself.When a certificate is updated the
certificate is released under the same number with a new date.(FM-United States: FM20US0123X, effective from 03-2021)

GS 12D07J04-01EN-P
15
7.2 Control drawing: D&E 2020-024-A50 (part 1)

GS 12D07J04-01EN-P
16
7.3 Remarks:
1. No revision to this drawing without prior approval of FM.
2. Installation must be in accordance with the National Electrical Code (ANSI/NFPA 70), ANSI/ISA-RP12.06.01,
and relevant local codes.
3. The sensor shall be installed to a certified intrinsically safe HOST with the following maximum values: Uo= 14.4
V, Io = 116.5 mA, Po = 342.4 mW.
4. The sensor does not provide isolation from earth. Installers shall take necessary measures to prevent the
possibility of sparking resulting from differing earth potentials between the sensors and interconnecting
equipment. This can be realized for example by selecting interconnecting equipment which provides input-to-
output and input-to-earth isolation up to 500 V rms.
5. Sensor Model code:

7.4 Model and Suffix codes


Model Suffix Code Option Code
SC4A -a-bc-de-fgh-ij-kl /m
a Material T - Titanium
S - Stainless Steel, Viton sealing
E - Stainless Steel, EPDM sealing
bc Fitting type Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
de Sensor length Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
egh Cell Constant Three alphanumeric characters (A to Z, 0 to 9 or a hyphen)
VS - Connector with ID-chip. Two alphanumeric characters
ij Connection type identifying the length of the permanent cable, each
character from 0 to 9
kl Temp. sensor + Region T1 Pt1000, IS for ATEX/IECEx, FM-US, FM-CAN
m Option code Up to ten alphanumeric characters (A to Z, 0 to 9 or hyphen)

7.5 WARNING - POTENTIONAL ELECTROSTATIC CHARGING HAZARD (see instructions)


pH sensors containing accessible plastic parts and/or external conductive parts, must be installed and used in such
a way, that dangers of ignition due to hazardous electrostatic charges cannot occur, especially in the case that the
process medium is non-conductive.

WARNING - POTENTIONAL IGNITION HAZARD (see instructions)


Contact Conductivity sensors containing light metals, must be installed, and used in such a way that, even in the
event of rare incidents, ignition sources due to impact and friction sparks are excluded.

GS 12D07J04-01EN-P
17
7.6 Control drawing: D&E 2020-024-A50 (part 2)

GS 12D07J04-01EN-P
18
7.7 Remarks:
1. No revision to this drawing without prior approval of FM.
2. Installation must be in accordance with the National Electrical Code (ANSI/NFPA 70), ANSI/ISA-RP12.06.01,
and relevant local codes.
3. The sensor shall be installed to a certified intrinsically safe Smart Adapter, model SA11-C1, with the following
maximum values: Uo= 6.6 V, Io = 100 mA, Po= 165 mW.
4. The Installers shall take necessary measures to prevent the possibility of sparking resulting from differing earth
potentials between the sensors and interconnecting equipment. The sensor itself does not provide 500 V rms
isolation from e arth, the interconnecting equipment Model SA11-C1 Smart Adapter however provides this
required isolation.
5. Sensor Model code:

7.8 Model and Suffix codes


Model Suffix Code Option Code
SC4A -a-bc-de-fgh-ij-kl /m
a Material T - Titanium
S - Stainless Steel, Viton sealing
E - Stainless Steel, EPDM sealing
bc Fitting type Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
de Sensor length Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
egh Cell Constant Three alphanumeric characters (A to Z, 0 to 9 or a hyphen)
ij Connection type VS - Connector with ID-chip.
kl Temp. sensor + Region T1 Pt1000, IS for ATEX/IECEx, FM-US, FM-CAN
m Option code Up to ten alphanumeric characters (A to Z, 0 to 9 or hyphen)

7.9 WARNING - POTENTIONAL ELECTROSTATIC CHARGING HAZARD (see instructions)


pH sensors containing accessible plastic parts and/or external conductive parts, must be installed and used in such
a way, that dangers of ignition due to hazardous electrostatic charges cannot occur, especially in the case that the
process medium is non-conductive.

WARNING - POTENTIONAL IGNITION HAZARD (see instructions)


Contact Conductivity sensors containing light metals, must be installed, and used in such a way that, even in the
event of rare incidents, ignition sources due to impact and friction sparks are excluded.

GS 12D07J04-01EN-P
19
7.10 FM-Canada
Applying standards : CAN/CSA-C22.2 No. 60079-0
CAN/CSA-C22.2 No. 60079-11
Certificate no.* : FM20CA0062X
S CL I, DIV 1, GP ABCD, T4…T6 CL I, ZN 0, Ex ia IIC, T4…T6 Ga
Control Drawing: D&E 2020-024-A51
Electrical data : (See Note 1)
Specific conditions of use : See Control Drawing D&E 2020-024-A51.
Temperature classes for SC4A models are defined T4…T6 (See Note 1).

Note 1 : Intrinsically safe, entity, for Class I, Division 1, Groups A, B, C and D; Class I, Zone 0, Ex ia IIC, Ga (entity) for
hazardous (classified) locations When installed per control drawing D&E 2020-024-A51.
Maximum sensor input parameters:
Ui= 14.4 V; Ii= 116.5 mA; Pi= 0.3424 W;
Li= 0.1 mH (models with fixed cable) or Li= 0 mH (VS type);
Ci= 150 nF (models with fixed cable) or Ci= 0.4 nF (VS type
Ambient temperature:
- 30°C to +40°C for temperature class T6,
- 30°C to +95°C for temperature class T5,
- 30°C to +125°C for temperature class T4 (VS type),
- 30°C to +130°C for temperature class T4 (models with fixed cable).

When the sensor has been connected to non intrinsically safe


equipment which exceeds the restrictions regarding the sensor input
circuits, the sensor is not suitable anymore for intrinsically safe use.

* Certification is subject to change, due to new regulations or changes in the product itself. When a certificate is updated the
certificate is released under the same number with a new date. - FM-Canada: FM20CA0062X (effective from 03-2021)

GS 12D07J04-01EN-P
20
7.11 Control drawing: D&E 2020-024-A51 (part 1)

GS 12D07J04-01EN-P
21
7.12 Remarks:
1. No revision to this drawing without prior approval of FM.
2. Installation must be in accordance with the National Electrical Code (CEC) CSA22.1 and relevant local codes.
3. The sensor shall be installed to a certified intrinsically safe HOST with the following maximum values: Uo= 14.4
V, Io = 116.5 mA, Po = 342.4 mW.
4. The sensor does not provide isolation from earth. Installers shall take necessary measures to prevent the
possibility of sparking resulting from differing earth potentials between the sensors and interconnecting
equipment. This can be realized for example by selecting interconnecting equipment which provides input-to-
output and input-to-earth isolation up to 500 V rms.
5. Sensor Model code:

7.13 Model and Suffix codes


Model Suffix Code Option Code
SC4A -a-bc-de-fgh-ij-kl /m
a Material T - Titanium
S - Stainless Steel, Viton sealing
E - Stainless Steel, EPDM sealing
bc Fitting type Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
de Sensor length Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
egh Cell Constant Three alphanumeric characters (A to Z, 0 to 9 or a hyphen)
VS - Connector with ID-chip
ij Connection type Two alphanumeric characters identifying the length of the
permanent cable, each character from 0 to 9.
kl Temp. sensor + Region T1 Pt1000, IS for ATEX/IECEx, FM-US, FM-CAN
m Option code Up to ten alphanumeric characters (A to Z, 0 to 9 or hyphen)

7.14 WARNING - POTENTIONAL ELECTROSTATIC CHARGING HAZARD (see instructions)


pH sensors containing accessible plastic parts and/or external conductive parts, must be installed and used in such
a way, that dangers of ignition due to hazardous electrostatic charges cannot occur, especially in the case that the
process medium is non-conductive.

WARNING - POTENTIONAL IGNITION HAZARD (see instructions)


Contact Conductivity sensors containing light metals, must be installed, and used in such a way that, even in the
event of rare incidents, ignition sources due to impact and friction sparks are excluded.

GS 12D07J04-01EN-P
22
7.15 Control drawing: D&E 2020-024-A51 (part 2)

GS 12D07J04-01EN-P
23
7.16 Remarks:
1. No revision to this drawing without prior approval of FM.
2. Installation must be in accordance with the National Electrical Code (CEC) CSA22.1 and relevant local codes.
3. The sensor shall be installed to a certified intrinsically safe Smart Adapter, model SA11-C1, with the following
maximum values: Uo= 6.6 V, Io = 100 mA, Po = 165mW.
4. The Installers shall take necessary measures to prevent the possibility of sparking resulting from differing
earth potentials between the sensors and interconnecting equipment. The sensor itself does not provide 500 V
rms isolation from earth, the interconnecting equipment Model SA11-C1 Smart Adapter however provides this
required isolation.
5. Sensor Model code:

7.17 Model and Suffix codes


Model Suffix Code Option Code
SC4A -a-bc-de-fgh-ij-kl /m
a Material T - Titanium
S - Stainless Steel, Viton sealing
E - Stainless Steel, EPDM sealing
bc Fitting type Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
de Sensor length Two alphanumeric characters (A to Z, 0 to 9 or a hyphen)
egh Cell Constant Three alphanumeric characters (A to Z, 0 to 9 or a hyphen)
ij Connection type VS - Connector with ID-chip
kl Temp. sensor + Region T1 Pt1000, IS for ATEX/IECEx, FM-US, FM-CAN
m Option code Up to ten alphanumeric characters (A to Z, 0 to 9 or hyphen)

7.18 WARNING - POTENTIONAL ELECTROSTATIC CHARGING HAZARD (see instructions)


pH sensors containing accessible plastic parts and/or external conductive parts, must be installed and used in such
a way, that dangers of ignition due to hazardous electrostatic charges cannot occur, especially in the case that the
process medium is non-conductive.

WARNING - POTENTIONAL IGNITION HAZARD (see instructions)


Contact Conductivity sensors containing light metals, must be installed, and used in such a way that, even in the
event of rare incidents, ignition sources due to impact and friction sparks are excluded.

GS 12D07J04-01EN-P
Yokogawa has an extensive sales
and distribution network.
Please refer to the European website
(www.yokogawa.com/eu) to contact
your nearest representative.

All Rights Reserved. Copyright © 2021, Yokogawa Process Analyzers Europe BV GS 12D07J04-01EN-P Nov.11, 2021-02
Subject to change without notice. Printed in The Netherlands

You might also like