Optical Fibre Cable Technical Specification
Version ADSS-V1.0
Optical Fibre Cable Technical Specification
Aerial Cable
ADSS-SS-100M-6/12/24/48B1.3
Yangtze Optical Fibre and Cable Joint Stock Limited Company
All rights reserved
www.yofc.com All Rights Reserved Copyright © 2014
Optical Fibre Cable Technical Specification
1. Optical Cable
1.1 Technical Characteristics
The unique second coating and stranding technology provide the fibres with enough space and bending
endurance, which ensure good optical property of the fibres in the cable
Accurate process control ensures good mechanical and temperature performance
High quality raw material guarantees the long service life of cable
1.2 Cross Section of Cable
Fiber
Tube Filling Compound
Loose Tube
Water Blocking Tape
Aramide Yarn
Water Blocking Yarn
FRP Strength Member
PE Sheath
Rip Cord
Filler
ADSS-SS-100M-6B1.3
Fiber
Tube Filling Compound
Loose Tube
Water Blocking Tape
Aramide Yarn
Water Blocking Yarn
FRP Strength Member
PE Sheath
Rip Cord
Filler
ADSS-SS-100M-12B1.3
www.yofc.com All Rights Reserved Copyright © 2014
Page: 2 of 6
Optical Fibre Cable Technical Specification
Fiber
Tube Filling Compound
Loose Tube
Water Blocking Tape
Aramide Yarn
Water Blocking Yarn
FRP Strength Member
PE Sheath
Rip Cord
Filler
ADSS-SS-100M-24B1.3
Fiber
Tube Filling Compound
Loose Tube
Water Blocking Tape
Aramide Yarn
Water Blocking Yarn
FRP Strength Member
PE Sheath
Rip Cord
Filler
ADSS-SS-100M-48B1.3
1.3 Fibre and Loose Tube Identification
The color code of fibres and loose tube will be identification in accordance with the following color
sequence, other sequence also is available.
1 2 3 4 5 6
Blue Orange Green Brown Grey White
Color Code
7 8 9 10 11 12
Red Black Yellow Violet Pink Aqua
The color of the fillers will be natural.
www.yofc.com All Rights Reserved Copyright © 2014
Page: 3 of 6
Optical Fibre Cable Technical Specification
1.4 Dimensions and Descriptions
The standard structure of ADSS cable is shown in the following table, other structure and fibre count are
also available according to customer requirements.
Value
Item contents
6 12 24 48
number 1 2 4
Loose
tube Outer diameter
2.1 2.4
(mm)
Filler number 4 3 1
Max.
fiber
G.652D 6 12
counts
per tube
material FRP
Central diameter (mm) 1.6 1.8
strength
member PE layer
-
diameter (mm)
Water
Blocking Material Water Blocking Tape & Yarn
Material
Strength
Material Braided aramid yarn
member
Material HDPE, with UV protection, anti fungi
Color Black
Sheath
Thickness
Nominal: 1.5
(mm)
Ripcord number 2 (opposite sides)
Color Color and
-
Strip Dimension
Cable diameter(mm) 9.4 10.3
Cable weight(kg/km) 65 75
Approx.
www.yofc.com All Rights Reserved Copyright © 2014
Page: 4 of 6
Optical Fibre Cable Technical Specification
1.5 Main Mechanical and Environmental Performance
Crush(N/100mm)
Short term Long term
2200 1100
Environmental and installation condition:
Max. wind speed Max. ice thickness Initial Installation sag Tempreture
25m/s Our 90Km/h 0 1.0% -40~+70℃
2 Mechanical, Physical and Environmental Test Characteristics
The mechanical and environmental performance of the cable are in accordance with the following table.
Unless otherwise specified, all attenuation measurements required in this section shall be performed at
1550nm.
Items Test Method Requirements
IEC 60794-1-2-E1
Load: According to 3.5 Additional attenuation: ≤0.1dB after test
Tension
Sample length: Not less than 50m. No damage to outer jacket and inner elements
Duration time: 1min.
IEC 60794-1-2-E3
Additional attenuation: ≤0.1dB after test
Crush Load: According to 3.5
No damage to outer jacket and inner elements
Duration of load: 1min
IEC 60794-1-2-E4
Radius: 300 mm
Additional attenuation: ≤0.1dB
Impact Impact energy: 10 J
Impact number: 1 No damage to outer jacket and inner elements
Impact points: 3
IEC 60794-1-2-E11A
Mandrel radius: 10*D Additional attenuation: ≤0.1dB
Bend
Turns:4 No damage to outer jacket and inner elements
Cycles:3
IEC 60794-1-2-E6
Repeated Bending radius: 20*D Additional attenuation: ≤0.1dB
bending Cycles: 25 No damage to outer jacket and inner elements
Load: 150N
IEC 60794-1-2-E7
Cycles:10
Additional attenuation: ≤0.1dB
Torsion Length under test: 1m
No damage to outer jacket and inner elements
Turns: 180°
Load: 150N
IEC 60794-1-2-F5B
Water
Time : 24 hours No water leakage.
Penetration
Sample length : 3m
www.yofc.com All Rights Reserved Copyright © 2014
Page: 5 of 6
Optical Fibre Cable Technical Specification
Water height : 1m
IEC 60794-1-2-F1
Sample length: at least 1000m
Temperature Temperature range: -40℃~+70℃ The change in attenuation coefficient shall be
cycling Cycles: 2 less than 0.05 dB/km at 1310 and 1550nm.
Temperature cycling test dwell
time: 12 hours
Other
According to IEC 60794-1
parameters
3 Packaging and Drum
3.1 Cable Sheath Marking
Unless otherwise specified, the cable sheath marking shall be as follows:
Color: white
Contents: YOFC, the year of manufacture, the type of cable, cable number, length marking
Interval: 1±0.2% m
Outer sheath marking legend can be changed according to user’s requests.
3.2 Reel Length
Standard reel length: 4 km/reel, other length is also available.
3.3 Cable Drum
The cables are packed in fumigated wooden drums.
3.4 Cable Packing
Both ends of the cable will be sealed with suitable plastic caps to prevent the entry of moisture during
shipping, handling and storage. The inner end is available for testing.
www.yofc.com All Rights Reserved Copyright © 2014
Page: 6 of 6