0% found this document useful (0 votes)
148 views1 page

Master Table: General Energy Conservation Special Notes

This document contains a summary of the electrical details for a building permit, including the building description, type of permit, electrical equipment details, total and active load details, meter details, and a note about energy conservation regulations. The building is a store with supply coming from an MV panel and a diesel generator. Equipment includes 500A breakers and MCCB/MCB sizes of 470.28A and 275.81A respectively. The meter is 800/5A with CT and DC/CT/VT details.

Uploaded by

Siyad p salam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views1 page

Master Table: General Energy Conservation Special Notes

This document contains a summary of the electrical details for a building permit, including the building description, type of permit, electrical equipment details, total and active load details, meter details, and a note about energy conservation regulations. The building is a store with supply coming from an MV panel and a diesel generator. Equipment includes 500A breakers and MCCB/MCB sizes of 470.28A and 275.81A respectively. The meter is 800/5A with CT and DC/CT/VT details.

Uploaded by

Siyad p salam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MASTER TABLE

Type of Breaker
Building Description Type of Building Permit
Size
Load Meter Description Energy Conservation Special Notes
Total Load Active Load E/Meter W/ Meter W/ Meter W/ Main Pipe W/ Service
Type Floor No. Flat No. BP No. MOC IN MCCB/A MCB/A
(KW) (KW)
Meter No.
Serial No.
CT/Ratio A/5 DC/CT/VT
No. No. size Pipe size
General
SUPPLY FROM Design and conservation of building shall comply with
STORE N/A N/2019/0007441 500 A 470.28 275.81 800/5A CT 22 22
MV PANEL
the provisions of the following KAHRAMAA regulations
DIESEL GENERATOR
STORE N/A N/2019/0007441 500 A 800/5A CT
SUPPLY
1) Regulation for the installation of electrical wiring,
electrical equipment and air conditioning equipment
KAHRAMAA NOTES: December 2010 edition
* The electrical installation shall be carried out in compliance with the
current edition of " The Regulations For Installation Of Electrical Wiring,
Electrical Equipment And Air Conditioning Equipment". Electrical installation
* MV panel details/manufacturer's drawings shall be submitted to Qatar
General Electricity And Water Corporation (KAHRAMAA) for prior All possible energy saving measures adopted in lighting sector
approval before it is manufactured.
Energy saving lamps is proposed wherever applicable
* Total voltage drop shall be not exceed 2.5%.
* Power factor shall not be lower than 0.90. Control systems are provided for lighting and A/C as applicable
* This approval covers only the revision/modification as indicated in the Timer and / or photocell control is ensured for the external lighting
SLD/drawing. All others details shall be as per the previous approval
under BP# ______.
HVAC Installation
Necessary provisions are included in design / construction to

FOR BOOSTER PUMP = 3.0KW

200 KVAR CAPACITOR BANK


FOR JOCKEY PUMP = 3.0KW
reduce the cooling load and corresponding electrical demands

FOR FIRE PUMP = 60.0KW


by properly selecting building materials, insulation to walls and

200 A TP ISOLATOR
roof and energy efficient windows as applicable

32 A TP ISOLATOR

32 A TP ISOLATOR
MSB4 = 153.90 KW
MSB2 = 70.90 KW

MSB5 = 77.50 KW

MSB6 = 37.38 KW
MSB3 = 36.4 KW
DBmv = 4.20 KW

MSB1 = 24.0KW
All air conditioning equipments are sized and selected as per
cooling load calculations

Energy efficiency and conservation measures are considered


while selecting HVAC systems and equipments
4Cx120mm²XLPE/SWA/PVC

4Cx120mm²XLPE/SWA/PVC

4Cx300mm²XLPE/SWA/PVC
4Cx35mm²XLPE/SWA/PVC

4Cx16mm²XLPE/SWA/PVC

4Cx70mm²XLPE/SWA/PVC

4Cx35mm²XLPE/SWA/PVC

4Cx16mm²XLPE/SWA/PVC

4Cx16mm²XLPE/SWA/PVC

4Cx50mm²XLPE/SWA/PVC
2Cx10mm²MICC CABLE

+1Cx150mm²PVC/ECC
+1Cx10mm²PVC/ECC

+1Cx16mm²PVC/ECC

+1Cx16mm²PVC/ECC

+1Cx70mm²PVC/ECC

+1Cx35mm²PVC/ECC

+1Cx16mm²PVC/ECC

+1Cx70mm²PVC/ECC

+1Cx16mm²PVC/ECC

+1Cx16mm²PVC/ECC

+1Cx25mm²PVC/ECC

VD=1.1 volts
L=36.7 mtrs.
U.D.D STAMP MUNICIPALITY STAMP

4Cx50mm²XLPE/SWA/PVC
SPACE

+1Cx25mm²PVC/ECC
40A TP* 80A TP 50A TP 200A TP 100A TP 80A TP 200A TP 32A TP 32A TP 200A TP 200A TP

VD=1.1 volts
L=36.7 mtrs.
MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB SPACE MCCB MCCB

Note for AMI provisioning :


800A, 4 POLE BUSBAR All required provisioning for AMI shall be implemented as per
AMPERE RATING MCCB
KAHRAMAA Regulations titled: Low Voltage Electricity & Water
PANEL BOARD
100A TP Installations Regulations-ADVANCED METERING INFRASTRUCTURE CODE 2016.
ATS

LVP Note:
4Cx50mm²XLPE/SWA/PVC THERMAL INSULATION SPECFICATION ARE AS PER Enquiry No. : xx / xxxx / xx Application No : xx / xxxx / xx
+1Cx16mm²PVC/ECC
MINISTERIAL DECREE NO. 108 OF THE YEAR 2015. CONSULTANT REG. No : 264/L GRADE : C CONSULTANT REG. No : 000000 GRADE : A
GCP CABLE SHOULD NOT BE LE AT WET AREA. CONSULTANT STAMP & SIGNATURE : SUB-CONSULTANT STAMP & SIGNATURE :

G 100 KVA GENERATOR

1-THE ELECTRICAL INSTALLATIONS SHALL BE CARRIED OUT IN COMPLIANCE


WITH THE CURRENT EDITION OF "REGULATIONS FOR INSTALLATIONS OF
ELECTRICAL WIRING, ELECTRICAL EQUIPMENT AND AIR CONDITIONING
EQUIPMENT".

2-MV PANEL DETAILS/MANUFACTURER'S DRAWINGS SHALL BE SUBMITTED TECHNIQAL MANAGER : MOHAMED DALAIN TECHNIQAL MANAGER XXXXX
TO QATAR GENERAL ELECTRICITY & WATER CORPORATION(KAHRAMAA) REGISTRATION No. : 2659 REGISTRATION No : XXXXX
FOR PRIOR APPROVAL BEFORE IT'S MANUFACTURED .
3-TOTAL VOLTAGE DROP SHALL NOT EXCEED 2.5 % .
4-POWER FACTOR SHALL NOT BE LOWER THAN 0.90 .
PANORAMA ENGENEERING CONSULTANCY
5-THIS APPROVAL COVERS ONLY THE REVISION/MODIFICATION AS
DESIGN - PLANING - SUPERVISION
INDICATED IN THE SLD/DRAWING.ALL OTHER DETAILS SHALL BE AS AND PROJECT MANAGEMENT

PER THE PREVIOUS APPROVAL UNDER BP# ________. [email protected]

NOTE : PRO. ACCOMMODATION(G+2)+STORE (G+M)+


ELECTRICITY & WATER SMART METERS SHALL
BE SUPPLIED AND INSTALLED BY OWNER AS
+SHOW ROOM+OFFICE & GUARD ROOM
PER KAHRAMAA SPECIFICATION AND SUBJECT
TO KAHRAMAA APPROVAL.
AL WAKRA-LOGISTICS PARK
LVP FOR MORE DETAILS ON METER TYPES;
REFER TO KAHRAMAA WEBSITE. VINTAGE DESIGN
22-12-2019

1:100

SAIFUDDIN ENG BILAL ENG SHAZA


REGISTRATION No. : REGISTRATION No. :
000000 000000
SIGNATURE SIGNATURE