Wind Turbines & Hybrid Systems
Wind Turbines & Hybrid Systems
MODERN
WIND TURBINES
AND HYBRID
SYSTEMS
www.hipar.pl
|2
100%
SCIENTIFIC POTENTIAL Polish products
13
Silent operation
landform, level of the average wind speed which makes it an unmatched on the wind direction quality
company in comparison to other companies.
years Resistance to strong wind Aesthetic appearance
Low starting speed
– approx. 1 m/s
on the market Simple mechanical
construction enabling High strength Service-free operation
failure-free operation
Possible operation at
Durability temperatures ranging Absence of friction devices
from -40°C to +70°C
Wings and arms Aluminium structure with resistance tested in extreme conditions
Aerodynamic shape
of the blades
Resistance to extreme Brake Electromagnetic Electromagnetic and electromechanical additionally
wind blasts
Operation system On-Grid/Off-Grid/Hybrid
Controller Microprocessor
24/48/96V DC
Inverter output voltage 1x230V AC or 3x230V AC 50Hz 3x230V AC 50Hz
or 230V AC
Efficient generator
Mast types Concrete posts, metal posts, lattice work, and roof platforms
/ gearless system
Possible structure manufacturing to individual order
Mast sizes 2 m to 25 m
Weather resistant
construction
Compliance with standards CE,IEC 61400-2, 61400-11
www.hipar.pl www.hipar.pl
5| | 6
USE OF TURBINES
TYPES OF MASTS
1. On-grid system/ On-grid hybrid system
6 9
a solution usually applied when a building is connected to power engineering network.
It is one of the simplest systems consisting of a wind turbine of any capacity, grid
1
inverter of the output voltage of 1 x 230 V AC or 3 x 230 V A, two-directional meter to
4 measure the power generated and consumed, security measures in the form of circuit
5
8 breakers and surge arresters, turbine stopping resistor and connection to the power
grid. On-Grid systems may also be developed for photovoltaic modules, thus creating PRE-STRESSED MAST
Hybrid systems. Moreover, batteries saving surplus power may be installed. In case of
frequent power failures from the grid, the system may be additionally provided with a
2 diesel generator.
An On-Grid system enables the use of directly generated power and resale of the are made by concrete pouring into a rotating conical mould,
7
power in case of energy surpluses or accumulation in the power grid. which ensures high technical parameters and smooth surface.
The masts are characterised with long-lasting operation and
durability. They are cheaper than other masts of similar
heights. An attachment with platform for turbine installation is
needed for a pre-stressed mast.
9
6 a solution combining the advantages of On-Grid and Off-Grid systems. An On/Off-Grid
system removes the problem of power failure, usually as a result of weather anomaly,
1 power grid repair, etc. The system first of all accumulates surplus energy in batteries
4 and uses the accumulated energy when the wind turbine combined with the additional
5
8 photovoltaic panels are not generating enough energy, or uses the batteries in case of
3
complete grid failure. The battery of specific capacity takes missing energy from the FLAT-ROOF MAST
power grid through the system controlling inverter as soon as the battery has been
2 completely discharged. The system may also output energy to the gird when the
have the form of latticework of large span between the legs,
batteries are fully loaded and the energy generated by the wind turbine and the
7 which ensures stability and durability of the structure. It is
photovoltaic panels is sufficient for the building supply.
possible to design a mast which does not reach higher than
three metres above the roof. Four structure elements ensure
simple transport, installation and dismantling. On flat roofs
two vibration damping connectors are additionally applied in
Legend
order to minimise the vibrations transferred to the building.
1. Ecorote wind turbine 2. Inverter/hybrid controller 3. Batteries 4. 230V receivers 5. Water heater / hot water / heating
6. Photovoltaic panels (in a hybrid system) 7.Generator (optional) 8. Switch /AC counter 9. Network
www.hipar.pl www.hipar.pl
7| | 8
Argentina Buenos Aires 5,5 3225 2612 Morocco Marrakech 5,8 3992 3234
Canada Ottawa 7,7 12287 9952 Portugal Lisbon 7,1 8955 7254
Czech Republic Prague 5,4 2994 2425 Vladivostok 6,5 6305 5107
Denmark Copenhagen 6,4 5926 4800 South Africa Capetown 7,4 10533 8532
Hungary
Athens
Budapest
6,2
6,6
5218
3224
4227
2611
Glasgow 6,7 7115 5763 Created for maximum use of solar energy
United Kingdom Liverpool 7,6 11683 9463
Iceland Reykjavik 8,8 20181 16347
London 5,3 2777 2249
India Mumbai 3,8 721 584
PV trackers (follow-up systems) are devices that increase the efficiency of a photovoltaic system by up to approx.
Kanzas 6,6 6701 5428
Dublin 7,8 12910 10457
Ireland USA 45% per year, by reducing the losses resulting from the sunlight angle. The movement of the panels prevents
New York 6,3 5564 4507
Waterford 8,3 16316 13216
the deposition of dust and other contaminants that can cause the effect of local overheating of the panels.
Israel Tel Aviv 5,7 3722 3015
The follow-up system increases productivity of inverters that control the process of electricity generating from
Catania 4,6 1567 1269
3000W 8000W
Vilnius 5,7 3722 3015
it is driven by two German K + G cylinders and coronary
Mexico Mexico 5,2 2572 2083
transmission designed for reliable operation in extreme to
weather conditions.
www.hipar.pl www.hipar.pl
9| |10
Resistance to
weather conditions Work safety Our turbines and trackers have been evaluated as products with unparalleled
performance and parameters by independent research units. With a specialized
technical and design personnel and over 20 years of experience in the mechanical
industry our company, in addition to production of turbines and tracker, deals
As well as Investors with the automotive industry used by companies such as Volvo, Volkswagen,
private Mercedes , BMW, Festo, Caterpillar and many others.
Noiseless
operation Reliability
of the device
Visual attractiveness
compared to stationary Reduction of area required
systems for the installation of PV
systems compared to stationary
systems,
Possibility of installation of the system
without building permits thanks
to use of the foundation placed
on the face of the ground.
www.hipar.pl www.hipar.pl
Producer
Wola Rafałowska 191a k/Rzeszowa
AUTHORIZED DISTIBUTOR