0% found this document useful (0 votes)
295 views7 pages

Wind Turbines & Hybrid Systems

This document discusses wind turbines and hybrid energy systems made by Hipar Sp. z o.o. It provides details on the company's history and products. Some key points: - Hipar has been manufacturing wind turbines and photovoltaic trackers since 2015, enabling 45% more energy from PV panels. - Their wind turbines, called ECOROTE, come in power ratings from 300W to 9800W and have been developed in cooperation with a university research institution. - The turbines are designed for independent, off-grid operation and have advantages like high manufacturing quality, silent operation, and no required maintenance.

Uploaded by

sina aftasi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
295 views7 pages

Wind Turbines & Hybrid Systems

This document discusses wind turbines and hybrid energy systems made by Hipar Sp. z o.o. It provides details on the company's history and products. Some key points: - Hipar has been manufacturing wind turbines and photovoltaic trackers since 2015, enabling 45% more energy from PV panels. - Their wind turbines, called ECOROTE, come in power ratings from 300W to 9800W and have been developed in cooperation with a university research institution. - The turbines are designed for independent, off-grid operation and have advantages like high manufacturing quality, silent operation, and no required maintenance.

Uploaded by

sina aftasi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

GREEN WIND ENERGY

MODERN
WIND TURBINES
AND HYBRID
SYSTEMS

www.hipar.pl
|2

100%
SCIENTIFIC POTENTIAL Polish products

+ TECHNOLOGY PARK = SUCCESS


HIPAR Sp. z o.o. was created in 2004. The registered office of the Company
is in Wola Rafałowska. At the beginning the main object of the Company
operations was machining of steel and cast iron elements. Since 2006
the main products of the Company have been pulleys to Volkswagen motors. THE ADVANTAGES
At that time the Company became a supplier of the pulleys for the production
lines of new motors. OF OUR WIND TURBINES
Since 2015 Hipar Sp. z o.o. has also manufactured equipment for independent
ECOROTE Wind Turbines Line It is our flagship product. We produce turbines with
operation of power plants outside of the power grid. Among other things, power ratings from 300W to 9800W.
the Company offers innovative vertical axis wind turbines (VAWT)
and photovoltaic trackers enabling the generation of 45% more energy ECOROTE turbines have been developed by our team of designers and constructors
from the PV panels compared to the stationary system. in close cooperation with the Rzeszow University of Technology's flagship research
institution specializing in Aviation.

Hipar as a production-trade enterprise provides an individual approach


to each customer, adapting all its offered products to customer needs
and environmental conditions i.e.: the geographical location, insolation, Operation independent High manufacturing

13
Silent operation
landform, level of the average wind speed which makes it an unmatched on the wind direction quality
company in comparison to other companies.
years Resistance to strong wind Aesthetic appearance
Low starting speed
– approx. 1 m/s
on the market Simple mechanical
construction enabling High strength Service-free operation
failure-free operation
Possible operation at
Durability temperatures ranging Absence of friction devices
from -40°C to +70°C

Resistance to any weather High quality of the applied


No overhauls required
conditions materials

Possibility to operate in On-Grid Water heating No detrimental impact


/Off-Grid/Hybrid systems on the environment

Simple installation at hotels, Polish engineering and


shops, blocks of flats, production manufacturing
halls and other buildings
3| | 4

THE ADVANTAGES TURBINE


OF TURBINE CONSTRUCTION PARAMETERS
A wind turbine allows for processing 71% (0.42 of Betz number) of wind energy into electricity. 98% of materials of which our
products are made come from Polish manufacturers. Disc generator that converts the kinetic energy of wind into electricity has been Turbine name ECOROTE 300 ECOROTE 1500 ECOROTE 2800 ECOROTE 9800
developed so as not to have friction elements, by which it excludes maintenance. The blades of the turbine, thanks to the use
of extruded aluminum profile of seamless monolith construction, are characterized by resistance to thermal expansion caused
Turbine power 300W 1500W 2800W 9800W
by heat. In addition, a white, sunlight reflecting paint, of C5+M resistance class is applied on the turbines. In addition, steel elements
are galvanized and aluminum elements are anodized in order to ensure their effective corrosion protection.
Impeller diameter 1 2,2 2,2 4

Turbine height 1,2 1,5 3 5,5

Starting speed 3 m/s 1,5m/s 1,25m/s 1,2m/s

Rated speed 10m/s 12m/s

Total weight 48 kg 155 kg 175 kg 550 kg

Wings and arms Aluminium structure with resistance tested in extreme conditions
Aerodynamic shape
of the blades
Resistance to extreme Brake Electromagnetic Electromagnetic and electromechanical additionally
wind blasts
Operation system On-Grid/Off-Grid/Hybrid

Controller Microprocessor

24/48/96V DC
Inverter output voltage 1x230V AC or 3x230V AC 50Hz 3x230V AC 50Hz
or 230V AC

Inverter output voltage 1 1 or 3 3

Generator output voltage AC

Noise level acc. to PN-EN


< 46 dB at 8 m/s in the distance of 60 m
61400-11

Operating temperature -40°C to +70°C

Corrosion protection Anodizing, galvanizing, powder coating C5+M

Efficient generator
Mast types Concrete posts, metal posts, lattice work, and roof platforms
/ gearless system
Possible structure manufacturing to individual order

Mast sizes 2 m to 25 m
Weather resistant
construction
Compliance with standards CE,IEC 61400-2, 61400-11

www.hipar.pl www.hipar.pl
5| | 6

USE OF TURBINES
TYPES OF MASTS
1. On-grid system/ On-grid hybrid system
6 9
a solution usually applied when a building is connected to power engineering network.
It is one of the simplest systems consisting of a wind turbine of any capacity, grid
1
inverter of the output voltage of 1 x 230 V AC or 3 x 230 V A, two-directional meter to
4 measure the power generated and consumed, security measures in the form of circuit
5
8 breakers and surge arresters, turbine stopping resistor and connection to the power
grid. On-Grid systems may also be developed for photovoltaic modules, thus creating PRE-STRESSED MAST
Hybrid systems. Moreover, batteries saving surplus power may be installed. In case of
frequent power failures from the grid, the system may be additionally provided with a
2 diesel generator.
An On-Grid system enables the use of directly generated power and resale of the are made by concrete pouring into a rotating conical mould,
7
power in case of energy surpluses or accumulation in the power grid. which ensures high technical parameters and smooth surface.
The masts are characterised with long-lasting operation and
durability. They are cheaper than other masts of similar
heights. An attachment with platform for turbine installation is
needed for a pre-stressed mast.

2. Off-grid system / Off-grid hybrid system


6
a perfect solution for buildings which are not connected to the power grid, e.g.
recreational houses, or in case the house residents wish to be completely
independent of the energy suppliers. The system is identical as the On-Grid one 1
but the battery is a must in order to store the surplus of the energy generated.
5
The system does not have to be connected to the power grid, so there is no need
for a two-directional meter. The system may be extended for photovoltaic panels
STEEL MAST WITH CABLE STAYS
and diesel generator, identically as in the case of an On-Grid system.
3
Both solutions have their advantages and disadvantages. An On-Grid system is
supplied by the power from the grid, so at the moment of power failure in the 2 are made of combined thin-wall tubes. Lightweight
grid the electric equipment in the house does not operate (except for the case
when a diesel generator is additionally installed). An Off-Grid system is connected
construction and the possibility of the mast disassembly into
7
to batteries, so there is no fear of power failure. The latter system is more short sections ensure comfortable transport. The stays fixed
expensive and there is no possibility to resale the generated power to the gird. to concrete anchors balance the stress that may be present.
The turbine is mounted directly on the mast, without any
additional attachments.

9
6 a solution combining the advantages of On-Grid and Off-Grid systems. An On/Off-Grid
system removes the problem of power failure, usually as a result of weather anomaly,
1 power grid repair, etc. The system first of all accumulates surplus energy in batteries
4 and uses the accumulated energy when the wind turbine combined with the additional
5
8 photovoltaic panels are not generating enough energy, or uses the batteries in case of

3
complete grid failure. The battery of specific capacity takes missing energy from the FLAT-ROOF MAST
power grid through the system controlling inverter as soon as the battery has been
2 completely discharged. The system may also output energy to the gird when the
have the form of latticework of large span between the legs,
batteries are fully loaded and the energy generated by the wind turbine and the
7 which ensures stability and durability of the structure. It is
photovoltaic panels is sufficient for the building supply.
possible to design a mast which does not reach higher than
three metres above the roof. Four structure elements ensure
simple transport, installation and dismantling. On flat roofs
two vibration damping connectors are additionally applied in
Legend
order to minimise the vibrations transferred to the building.
1. Ecorote wind turbine 2. Inverter/hybrid controller 3. Batteries 4. 230V receivers 5. Water heater / hot water / heating
6. Photovoltaic panels (in a hybrid system) 7.Generator (optional) 8. Switch /AC counter 9. Network

www.hipar.pl www.hipar.pl
7| | 8

Productivity analysis of ECOROTE 2800 turbine


for selected regions
PV TRACKERS
(follow-up systems)
Average Annual Co2 emissions Average Annual Co2 emissions
wind energy wind energy
production savings production savings
Country City speed in a year Country City speed in a year
[m/s] [kWh] [kg CO2] [m/s] [kWh] [kg CO2]

Argentina Buenos Aires 5,5 3225 2612 Morocco Marrakech 5,8 3992 3234

Melbourne 8,9 21006 17015 Netherlands Amsterdam 6,6 6701 5428


Australia
Sydney 8,1 14896 12066 Abuja 4,1 983 796
Nigeria
Austria Vienna 5,9 4276 3464 Lagos 5,5 3224 2611

Belarus Minsk 5,5 3224 2611 Bergen 8,4 17053 13813


Norway
Belgium Brussels 5,8 3992 3234 Oslo 7,2 9462 7664

Brazil Rio De Janeiro 6 4575 3706 Gdansk 6,8 7547 6113

Sofia 3,8 721 584 Poland Cracow 5,2 2572 2083


Bulgaria
Varna 5,4 2994 2425 Warsaw 5,4 2994 2425

Canada Ottawa 7,7 12287 9952 Portugal Lisbon 7,1 8955 7254

Beijing 5,5 3224 2611 Qatar Doha 5,8 3992 3234


China
Shanghai 6,7 7115 5763 Novosibirsk 5,9 4276 3464

Moscow 5,9 4276 3464


Dubrovnik 6,8 7547 6113 Russia
Croatia
Zagreb 4,5 1434 1162 St. Petersburg 6,9 7998 6478

Czech Republic Prague 5,4 2994 2425 Vladivostok 6,5 6305 5107

Denmark Copenhagen 6,4 5926 4800 South Africa Capetown 7,4 10533 8532

Barcelona 5,4 2994 2425


Estonia Tallinn 7,1 8955 7254
Spain Madrit 4,8 1862 1508
Finland Helsinki 7,2 9462 7664

Bordeaux 5,9 4276 3464 Malaga 6,4 5926 4800

Goteborg 7,1 8955 7254


France Marseille 7,8 12910 10457 Sweden
Paris 5,7 3722 3015 Sztokholm 6,7 7115 5763

Turkey Istanbul 6,6 6701 5428


Berlin 5 2195 1778
UAE Abu Dhabi 4 889 720
Germany Hamburg 6,3 5564 4507

Hannover 5,1 2378 1926 Kiev 5,3 2777 2249


Ukraine
Odessa 6,3 5564 4507
Greece

Hungary
Athens

Budapest
6,2

6,6
5218

3224
4227

2611
Glasgow 6,7 7115 5763 Created for maximum use of solar energy
United Kingdom Liverpool 7,6 11683 9463
Iceland Reykjavik 8,8 20181 16347
London 5,3 2777 2249
India Mumbai 3,8 721 584
PV trackers (follow-up systems) are devices that increase the efficiency of a photovoltaic system by up to approx.
Kanzas 6,6 6701 5428
Dublin 7,8 12910 10457
Ireland USA 45% per year, by reducing the losses resulting from the sunlight angle. The movement of the panels prevents
New York 6,3 5564 4507
Waterford 8,3 16316 13216
the deposition of dust and other contaminants that can cause the effect of local overheating of the panels.
Israel Tel Aviv 5,7 3722 3015
The follow-up system increases productivity of inverters that control the process of electricity generating from
Catania 4,6 1567 1269

Italy Milan 3,3 405 328


sunlight. The inverters work best at a high load, which is obtained only by using the follow-up systems. Through
Roma 4,1 983 796 the use of wind and snow/ice sensors in the control automation, we protect the tracker against adverse weather
An example amount of energy
Japan Tokyo 5,9 4276 3464 conditions.
Aktau 7,3 9988 8090
produced of the ECOROTE 2800
Kazakhstan
Almaty 6,4 5926 5926 turbine
Astana 6,9 7998 6478

Atyrau 7,6 11683 9463


(mounted at 15m height, taking with terrain PERFECTLY PRODUCED Hipar's offer includes trackers from
Latvia Riga 7,1 8955 7254 roughness class of 1 and a Weibull factor of k=2.6)
Klaipeda 6,6 6701 5428
Lithuania The structure is entirely made of steel and aluminum,

3000W 8000W
Vilnius 5,7 3722 3015
it is driven by two German K + G cylinders and coronary
Mexico Mexico 5,2 2572 2083
transmission designed for reliable operation in extreme to
weather conditions.

www.hipar.pl www.hipar.pl
9| |10

Advantages of the PV trackers produced BEST QUALITY


of products
by us include, e.g.:
Products Wind Turbines and Trackers produced by our company are of the utmost
manufactured quality. This is confirmed by the strength and agility results carried out byz:
by our company
collect more and more
Very high utilization of sunlight,
Flexible range of motion for each interest among
characterized by the possibility Increasing the efficiency
geographical location:
of the tracker perpendicular of the panels by approx.
adjusting towards the sun 45% per annum - The tilt angle of the panels:
at any time of the day from 1 deg. to 90 deg.
- The angle of rotation of panels:
from 0 deg. to 350 deg.
Polish Academy of Sciences, which placed our
turbine in the Polish Antarctic Station at the South
Pole (wind speed reaches up to 71 m / s)

Resistance to
weather conditions Work safety Our turbines and trackers have been evaluated as products with unparalleled
performance and parameters by independent research units. With a specialized
technical and design personnel and over 20 years of experience in the mechanical
industry our company, in addition to production of turbines and tracker, deals
As well as Investors with the automotive industry used by companies such as Volvo, Volkswagen,
private Mercedes , BMW, Festo, Caterpillar and many others.
Noiseless
operation Reliability
of the device

Increasing the Protection of


efficiency panel against
of inverters dust, dirt.

Visual attractiveness
compared to stationary Reduction of area required
systems for the installation of PV
systems compared to stationary
systems,
Possibility of installation of the system
without building permits thanks
to use of the foundation placed
on the face of the ground.

www.hipar.pl www.hipar.pl
Producer
Wola Rafałowska 191a k/Rzeszowa

tel.: +48 17 230 49 00


faks: +48 17 230 49 03
e-mail: [email protected]

AUTHORIZED DISTIBUTOR

You might also like