0% found this document useful (0 votes)
119 views2 pages

AR252 Humidity & Temperature Sensor

This document provides technical specifications for the AR252 humidity and temperature transducer. Key details include: - It uses an SHT31 sensor from Sensirion with an ABS and stainless steel mesh cover. - It can measure humidity from 0-100% RH with ±2% accuracy and temperature from -30-80°C with ±0.3°C accuracy. - Outputs include 4-20mA current, 0-10V voltage, or RS485 digital. It can be powered via current loop or external supply. - Programming and configuration can be done via keypad, RS485, or ARsoft-CFG software. It has an IP65 rating for dust and water resistance.

Uploaded by

costelchelariu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views2 pages

AR252 Humidity & Temperature Sensor

This document provides technical specifications for the AR252 humidity and temperature transducer. Key details include: - It uses an SHT31 sensor from Sensirion with an ABS and stainless steel mesh cover. - It can measure humidity from 0-100% RH with ±2% accuracy and temperature from -30-80°C with ±0.3°C accuracy. - Outputs include 4-20mA current, 0-10V voltage, or RS485 digital. It can be powered via current loop or external supply. - Programming and configuration can be done via keypad, RS485, or ARsoft-CFG software. It has an IP65 rating for dust and water resistance.

Uploaded by

costelchelariu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AR252 Humidity and temperature transducer

TECHNICAL DATA (the detailed data can be found in the user’s instruction)

Sensor SHT31 made by Sensirion, an ABS cover (slot width 1mm)


and a stainless steel wire mesh (slot width 0.15mm)
Measurement range 0÷100 %RH, -30÷80 °C
Measurement humidity ±2 %RH in the entire measurement range
acurancy
temperature ±0,3 °C in the entire measurement range
Hysteresis and stability ±0,8 %RH, long-term stability < 0,25 %RH / year
Okres pomiarowy 1s
AR252 Response time (63%) 8s (for air flow > 3,6km/h)
standard
Display (optional) LCD, 4 digits 10 mm
Outputs current (IH, IT) 2 x 4÷20 mA (2P), load RO< (Uzas-12) / 22 mA
voltage (UH, UT) 2 x 0÷10 V (3P), load IO<4,5 mA (Rw > 2,5 kΩ)
digital (not separated) RS485, MODBUS-RTU (slave)
Power supply for the 4÷20 mA 12÷36 Vdc (2-wire, 2P) supply from the current loop
AR252/L150
probe on for the 0÷10 V 18÷30 Vdc, current consumption: ~7mA (with and without an LCD)
a stainless steel
pipe version with RS485 9÷28 Vac or 9÷36 Vdc, current cons.: ~5mA (with and without an LCD)
PROGRAMMING Operating conditions air and neutral gases (do not pour water on the measurement probe)
standard -30÷80 °C, <100 %RH (no condensation)
AR252/LCD AR956 with an LCD display -20÷70 °C, <100 %RH (no condensation)
with a display COPYING
INSTALLATION DATA
a high class digital relative humidity and temperature sensor with a protective
n
filter (ABS material as a standard, slot width 1 mm, and steel wire mesh with Dimensions 58x94x35 mm
mesh size of 0.15 mm); Material polycarbonate
a probe integrated with the enclosure, external or on a stainless steel pipe
n
94 58
a current output, 4÷20 mA (2-wire, with power supply from the current loop); a
n 80
voltage output 0÷10 V (3-wire), or an RS485 interface 64

calculation of the dew/frost point [°C], relative humidity [g/m3] (calculations for
n 35
atmospheric pressure of 1,013 hPa) with possibility to link the calculated values to
Φ9
an analog output;
temperature compensation of humidity measurement, high measurement
n 58
45
stability Probe
Probe integrated with
programmable processing ranges for humidity and temperature
n integrated the enclosure
an LCD display with a keypad (option) that enables configuration of parameters
n with the enclosure channel design
45 AR252 AR252/T
configuration of parameters with the keypad, through the RS485 or PRG port
n
(programmer AR956 or AR955) and free ARsoft-CFG software that enables quick
setting and copying of all configuration parameters TERMINAL
protection rating IP65 provided by the enclosure which improves reliability of
n
AR252/I
operation thanks to high resistance to penetration of water and dust and surface ~1500
IT
condensation of steam inside of the device; an IP40 probe
100 lub 200

1 +
mA
_ R
power supply
available accessory filter with a metal wire mesh to protect the sensor against
o
n 2 IH 12÷36 Vdc
140 lub 240

mA _
dust V+
+ _ Ro
62 3 +

Contents of the package: Available accessories: NOTE:


- a transducer - a metal wire mesh filter (mesh size approx. 25 μm) The current loop IH must ALWAYS be closed
15
- a user instruction - an AR956 (or AR955) programmer even when it is not in use
External
- a warranty card - a RS485/USB converter Probe
probe AR252/U
Ordering method wit a wire on a stainless UT +
steel pipe 1
AR252 / o
/o
/o
/o AR252/2 AR252/L150 Rw V
GND _
AR252/L250 2
Probe intsalation method Code UH +
radial (standard) - 3
Rw V
Display Code back (to pipe, channel) T ~1500 4 GND _
power supply
LCD * LCD
without a display - Measurement probe type Code
5 GND 18÷30 Vdc
_
integrated with the enclosure (standard) - 6 V+ +
Output Code external with a 1,5m wire* 2
output 4÷20 mA I external in an enclosure with a 1,5m wire* 3
58 AR252/R485
output 0÷10 V U on a stainless steel pipe, 140 mm long* L150
interface RS485 RS485 on a stainless steel pipe, 240 mm long* L250
1 power supply
Order example: * options charged separately 9÷36 Vdc
2 9÷28 Vac
Note: for the standard design, only the output type must be stated e.g.: External probe
AR252 / I 45 JP1
in an enclosure 3 + RS
AR252 w/o display, outputs 4÷20mA, radially mounted probe and integrated with the enclosure with a wire
AR252 / LCD / U / L150 / T AR252/3 4 - RS
AR252 with a display, analog output 0÷10V, probe on a stainless steel pipe, 140mm long, installed in the back 94
of the enclosure (for channel installations) Version 3.0.0 2016-09-30

www.apar.pl APAR - Sales Office, 05-090 Raszyn, ul. Gałczyńskiego 6, tel. +48 22 101-27-31, +48 22 853-48-56 • email: [email protected]
CALIBRATION CERTIFICATE - DIGITAL HUMIDITY AND TEMPERATURE SENSORS
MADE BY SENSIRION

You might also like