0% found this document useful (0 votes)
2K views350 pages

HISENSE - Unutrasnje Jedinice

This document is an indoor unit technical catalog that contains specifications, dimensions, component details, electrical diagrams, and installation instructions for various indoor unit models, including: - Ceiling ducted units (low and high static pressure) - Low-height and slim low-height ceiling ducted units - DC low height ducted units - 4-way and mini 4-way cassette units - Ceiling and floor units - Wall mounted and floor concealed units - All fresh air and 1-way and 2-way cassette units - Console units It provides general technical data, selection data, and installation guidelines for proper handling and installation of the different indoor unit series.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views350 pages

HISENSE - Unutrasnje Jedinice

This document is an indoor unit technical catalog that contains specifications, dimensions, component details, electrical diagrams, and installation instructions for various indoor unit models, including: - Ceiling ducted units (low and high static pressure) - Low-height and slim low-height ceiling ducted units - DC low height ducted units - 4-way and mini 4-way cassette units - Ceiling and floor units - Wall mounted and floor concealed units - All fresh air and 1-way and 2-way cassette units - Console units It provides general technical data, selection data, and installation guidelines for proper handling and installation of the different indoor unit series.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 350

INDOOR UNITS Technical Catalog

INDOOR UNITS
Technical Catalog
Technical Data

Series

<Indoor Units>
• Ceiling Ducted Type (Low Static Pressure)
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd. • Ceiling Ducted Type (High Static Pressure)
• Low-Height Ceiling Ducted Type
Add: Hisense Information Industry Park 218,Qianwangang
Road, Qingdao Economic Development Zone,China • DC Low Height Ducted Type
Tel:+86-532-80879968 Fax:+86-532-80875929 • Slim Ceiling Ducted Type
Http: //www.hisensehitachi.com
E-mail: [email protected] • 4-Way Cassette Type
• Mini 4-Way Cassette Type
TC2 2017003E

• Ceiling & Floor Type


Specifications in this catalogue are subject to change without notice,in order that Hisense may bring the latest innovations to their customers.
• Wall Mounted Type
• Floor Concealed Type
• All Fresh Air Indoor Unit
• 2-Way Cassette Type
• 1-Way Cassette Type
TC2 2017003E
• Console Type
TC2 2017003E
Hisense

Hisense

Hisense
IMPORTANT NOTICE

Correct Disposal of this product


This marking indicates that this product should not be disposed with other
household wastes. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device, please use
the return and collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.

Hisense's
Hisense's
l The appliance is not to be used by children or person with reduced physical, sensory or mental
capabilities,or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.

l Children should be supervised that they do not play with the appliance.
l The appliance should not be installed in the laundry.


-CONTENTS-
1. Connectable Outdoor Units and Working Range ............................................................ 1
1.1 Connectable Outdoor Units .......................................................................................... 1
1.2 Working Range.............................................................................................................. 1
2.Necessary Tools.................................................................................................................. 2
3.Transportation and Handling ............................................................................................... 2
3.1 Transportation .............................................................................................................. 2
3.2 Handing of Indoor Unit ................................................................................................ 2
4. Indoor Unit Installation ...................................................................................................... 2
5.Celling ducted type (Low/High Static Pressure AVD) ......................................................... 3
5.1 General Data ............................................................................................................... 3
5.2 Dimensional Data ....................................................................................................... 10
5.3 Selection Data ............................................................................................................ 12
5.4 Component Data ........................................................................................................ 29
5.5 Control System ........................................................................................................... 33
5.6 Electrical Data ............................................................................................................. 35
5.7 Electrical Wiring Diagram ......................................................................................... 38
5.8 Indoor Unit Optional Parts ....................................................................................... 41
5.9 Factory-Supplied Accessories .................................................................................. 42
5.10 Installation................................................................................................................ 43
6. Low-Height / Slim Low-Height / DC Low Height Ducted Type (AVE)............................ 54
6.1 General Data ............................................................................................................. 54
6.2 Dimensional Data...................................................................................................... 58
6.3 Selection Data........................................................................................................... 59
6.4 Component Data ...................................................................................................... 70
6.5 Refrigeration Cycle ................................................................................................... 72
6.6 Electrical Data .......................................................................................................... 73
6.7 Electrical Wiring Diagram ...................................................................................... 75
6.8 Indoor Unit Optional Parts ..................................................................................... 77
6.9 Factory-Supplied Accessories ................................................................................ 78
6.10 Install ..................................................................................................................... 79
6.11 Refrigerant Piping Work ........................................................................................ 81
6.12 Electrical Wiring ..................................................................................................... 84
6.13 Test Run ................................................................................................................ 86
6.14 Common .................................................................................................................. 86
6.15 Setting of Dip Switches .......................................................................................... 87
6.16 Setting of Extemal Static Pressure.......................................................................... 88
7. 4-Way Cassette Type ...................................................................................................... 89
7.1 General Data ............................................................................................................... 89
7.2 Dimensional Data ....................................................................................................... 92
7.3 Selection Data ............................................................................................................ 93
7.4 Electrical Wiring Diagram............................................................................................ 104
7.5 Indoor Unit Optional Parts.......................................................................................... 105
7.6 Factory-Supplied Accessories ................................................................................... 106
7.7 Installation................................................................................................................... 111
7.8 Refrigerant Piping Work ............................................................................................. 110
7.9 Drain Piping ................................................................................................................ 111
7.10 Electrical Wiring ........................................................................................................ 112
7.11 Test Run ................................................................................................................... 114
7.12 Common.................................................................................................................... 115
8. Mini 4-Way Cassette Type ............................................................................................. 116
8.1 General Data ............................................................................................................... 116
8.2 Dimensional Data ....................................................................................................... 118
8.3 Selection Data ............................................................................................................ 119
8.4 Component Data ........................................................................................................ 124
8.5 Refrigeration Cycle ..................................................................................................... 125
8.6 Electrical Data ............................................................................................................. 126
8.7 Electrical Wiring Diagram .......................................................................................... 127
8.8 Indoor Unit Optional Parts ........................................................................................ 128
8.9 Factory-Supplied Accessories ................................................................................... 129
8.10 Install ........................................................................................................................ 130
8.11 Refrigerant Piping Work ........................................................................................... 135
8.12 Drain Piping .............................................................................................................. 136
8.13 Electrical Wiring ........................................................................................................ 137
8.14 Test Run .................................................................................................................... 139
8.15 Field Operation.......................................................................................................... 140
8.16 Filter Cleaning ............................................................................................................ 141
8.17 Troubleshooting ........................................................................................................ 142
9. Ceiling & Floor Type(AVV) ............................................................................................ 143
9.1 General Data ............................................................................................................... 143
9.2 Dimensional Data ....................................................................................................... 145
9.3 Selection Data ............................................................................................................ 146
9.4 Component Data ........................................................................................................ 149
9.5 Refrigeration Cycle ..................................................................................................... 150
9.6 Electrical Data ............................................................................................................. 151
9.7 Electrical Wiring Diagram .......................................................................................... 152
9.8 Indoor Unit Optional Parts ........................................................................................ 153
9.9 Factory-Supplied Accessories ................................................................................... 154
9.10 Install ........................................................................................................................ 156
9.11 Refrigerant Piping Work ........................................................................................... 159
9.12 Drain Piping .............................................................................................................. 160
9.13 Electrical Wiring ........................................................................................................ 162
9.14 Test Run .................................................................................................................. 163
9.15 Common .................................................................................................................. 164
9.16 Setting of Automatic Swing Louver ........................................................................ 165
9.17 Filter Cleaning .......................................................................................................... 165
9.18 Troubleshooting ...................................................................................................... 166
10. Wall Mounted Type ........................................................................................................ 167
10.1 General Data ............................................................................................................. 167
10.2 Dimensional Data ..................................................................................................... 169
10.3 Selection Data .......................................................................................................... 171
10.4 Component Data ...................................................................................................... 178
10.5 Refrigeration Cycle ................................................................................................... 180
10.6 Electrical Data ........................................................................................................... 181
10.7 Electrical Wiring Diagram ........................................................................................ 182
10.8 Indoor Unit Optional Parts ...................................................................................... 183
10.9 Factory-Supplied Accessories ................................................................................. 184
10.10 Installation............................................................................................................... 184
10.11 Refrigerant Piping Work ......................................................................................... 188
10.12 Drain Piping ............................................................................................................ 190
10.13 Electrical Wiring ...................................................................................................... 191
10.14 Test Run ................................................................................................................ 193
10.15 Common ................................................................................................................ 193
10.16 Setting of Automatic Swing Louver ....................................................................... 198
10.17 Automatic Control .................................................................................................. 198
10.18 Filter Cleaning ........................................................................................................ 198
10.19 Troubleshooting ..................................................................................................... 199
11. Floor Concealed Type(AVH) ........................................................................................... 200
11.1 General Data ............................................................................................................. 200
11.2 Dimensional Data ..................................................................................................... 201
11.3 Selection Data .......................................................................................................... 202
11.4 Component Data ...................................................................................................... 204
11.5 Refrigeration Cycle ................................................................................................... 205
11.6 Electrical Data ........................................................................................................... 206
11.7 Electrical Wiring Diagram ........................................................................................ 207
11.8 Indoor Unit Optional Parts ...................................................................................... 208
11.9 Factory-Supplied Accessories ................................................................................. 209
10.10 Installation Check ................................................................................................... 210
11.11 Installation.............................................................................................................. 210
11.12 Refrigerant Piping Work ......................................................................................... 211
11.13 Drain Piping ............................................................................................................ 213
11.14 Electrical Wiring ...................................................................................................... 213
11.15 Test Run ................................................................................................................ 214
11.16 Common ................................................................................................................ 215
11.17 Troubleshooting .................................................................................................... 216
12. All Fresh Air Indoor Unit(AVA) ........................................................................................ 218
12.1 General Data ............................................................................................................. 218
12.2 Dimensional Data ..................................................................................................... 220
12.3 Selection Data .......................................................................................................... 222
12.4 Component Data ...................................................................................................... 228
12.5 Refrigeration Cycle ................................................................................................... 229
12.6 Electrical Data ........................................................................................................... 231
12.7 Electrical Wiring Diagram ........................................................................................ 232
12.8 Indoor Unit Optional Parts ...................................................................................... 237
12.9 Factory-Supplied Accessories ................................................................................. 238
12. 10 Installation For Model(30~114) ........................................................................... 239
12.11 Refrigerant Piping Work For Model(30~114) ........................................................ 243
12.12 Drain Piping For Model(30~114) ........................................................................... 244
12.13 Electrical Wiring For Model(30~114) ..................................................................... 245
12.14 Common (For Model 30~114) ............................................................................. 247
12.15 Factory-Supplied Accessories(For Model 154~190) ............................................ 247
12.16 Installation (For Model 154~190) ......................................................................... 248
12.17 Refrigerant PipingWork (For Model 154~190) ...................................................... 251
12.18 Drain Piping ............................................................................................................ 253
12.19 Electrical Wiring ...................................................................................................... 254
12.20 Test Run(For Model:154~190)............................................................................... 256
13. 2-Way Cassette Type(AVL) ........................................................................................... 258
13.1 General Data ............................................................................................................. 258
13.2 Dimensional Data ..................................................................................................... 261
13.3 Selection Data .......................................................................................................... 262
13.4 Component Data ...................................................................................................... 271
13.5 Refrigeration Cycle ................................................................................................... 273
13.6 Electrical Data ........................................................................................................... 274
13.7 Electrical Wiring Diagram ........................................................................................ 275
13.8 Indoor Unit Optional Parts ...................................................................................... 276
13.9 Factory-Supplied Accessories ................................................................................. 277
13.10 Installation ............................................................................................................. 278
13.11 Refrigerant Piping Work ......................................................................................... 281
13.12 Drain Piping ............................................................................................................ 282
13.13 Electrical Wiring ...................................................................................................... 283
13.14 Test Run ................................................................................................................ 284
13.15 Common ................................................................................................................ 285
13.16 Setting of Automatic Swing Louver ...................................................................... 286
13.17 Filter Cleaning ........................................................................................................ 286
13.18 Troubleshooting .................................................................................................... 287
14. 1-Way Cassette Type(AVL) ........................................................................................... 288
14.1 General Data ............................................................................................................. 288
14.2 Dimensional Data ..................................................................................................... 290
14.3 Selection Data .......................................................................................................... 291
14.4 Component Data ...................................................................................................... 296
14.5 Refrigeration Cycle ................................................................................................... 297
14.6 Electrical Data ........................................................................................................... 298
14.7 Electrical Wiring Diagram ........................................................................................ 299
14.8 Indoor Unit Optional Parts ...................................................................................... 300
14.9 Factory-Supplied Accessories ................................................................................. 301
14.10 Installation ............................................................................................................. 302
14.11 Refrigerant Piping Work ......................................................................................... 305
14.12 Drain Piping ............................................................................................................ 306
14.13 Electrical Wiring ...................................................................................................... 307
14.14 Test Run ................................................................................................................ 306
14.15 Common ................................................................................................................ 309
14.16 Setting of Automatic Swing Louver ...................................................................... 310
14.17 Filter Cleaning ........................................................................................................ 311
14.18 Troubleshooting .................................................................................................... 311
15. Console Type(AVK) ............. ........................................................................................... 313
15.1 General Data ............................................................................................................. 313
15.2 Dimensional Data ..................................................................................................... 314
15.3 Selection Data .......................................................................................................... 315
15.4 Component Data ...................................................................................................... 320
15.5 Refrigeration Cycle ................................................................................................... 321
15.6 Electrical Data ........................................................................................................... 322
15.7 Electrical Wiring Diagram ........................................................................................ 323
15.8 Indoor Unit Optional Parts ...................................................................................... 324
15.9 Factory-Supplied Accessories ................................................................................. 325
15.10 Installation ............................................................................................................. 326
15.11 Refrigerant Piping Work ......................................................................................... 332
15.12 Drain Piping ............................................................................................................ 333
15.13 Electrical Wiring ...................................................................................................... 334
15.14 Test Run ................................................................................................................ 335
15.15 Common ................................................................................................................ 336
15.16 Filter Cleaning ........................................................................................................ 338
15.17 Troubleshooting ..................................................................................................... 339
Technical Data
1. Connectable Outdoor Units and Working Range

1.1 Connectable Outdoor Units

AVWT-86/96/114U(6/7/9)SR AVWT-76/96UESRX
Hi-Flexi M Series Hi-Flexi X Series
AVWT-136/154U(6/7/9)SS AVWT-114/136/154UESSX
-Heat Pump System
AVWT-182~460U(6/7/9)SZ AVWT-172~460UESZX
AVWT-76/96/114FE(7/9)SR Multi-Function System AFW-38/48/54U4SC
Hi-Flexi R Series AVWT-136/154/170FE(7/9)SS AVW-76/96/114UESR
AVWT-1190~510FE(7/9)SZ Hi-Flexi C Series AVW-76/96/114U7SR
AVWT-76/96TESRX AVW-76/96/114U9SR
Hi-Flexi X Series AVWT-114/136/154TESSX AVWT-76~114UK/8SNA
-Cooling only System
AVWT-172/460TESZX AVWT-136~170UK/8STA
Hi-Flexi G+ Series
Hi-Flexi M Series AVWW-28/38/48/54UC(2)SA AVWT-190~212UK/8S1A
-Water Source AVWW-76~190UE(7)SB AVWT-232~840UK/8SZA
AVW-38/48/54UC(2)SC AVWT-76/96/114UE(7)SRG
Hi-Flexi L Series
AVW-48/54UE(7)SC AVWT-136/154/170UE(7)SSG
Hi-Flexi G Series
AVW-28/34/43UC(2)SB AVWT-190~510UE(7)SZG
Hi-Flexi E Series
AVW-43UE(7)SB

1.2 Working Range

Power Supply
Working Voltage: 90% to 110% of the Rated Voltage
Voltage Imbalance: Within a 3% Deviation from Each Voltage at the Main Terminal of Iutdoor Unit Starting
Voltage: Higher than 85% of the Rated Voltage

Temperature Range
The temperature range are given in the following table (Except for All Fresh Air Indoor Unit).

Cooling Operation Heating Operation


Indoor Temperature: Minimum 21℃ DB/15.0℃ WB 15℃ DB
Maximum 32℃ DB/23.0℃ WB 27℃ DB
Outdoor Temperature: Minimum -20℃ WB *
-5℃ DB *
Maximum 43℃ DB * 15℃ WB *

For All Fresh Air Indoor Unit

Cooling Operation Heating Operation


Outdoor Temperature: Minimum 20℃ DB * -7℃ WB *
Maximum 43℃ DB * 15℃ WB *

*: The temperature may change depending on the outdoor units.

1
Necessary Tools

21 Wrench

R410A

2.5

2
5. Celling ducted type(AVD)

5.1 General Data

Indoor Unit Type Ceiling Ducted Type (Low Static Pressure)


Model AC 1 , 220-240V/50Hz AVD-07UXCSAL AVD-09UXCSAL AVD-12UXCSAL AVD-14UXCSAL AVD-17UXCSBL
Power Supply AC 1 , 220V/60Hz AVD-07UX2SAL AVD-09UXC2AL AVD-12UX2SAL AVD-14UX2SAL AVD-17UX2SBL
Nominal Cooling kW 2.3 2.9 3.8 4.4 5.2
Capacity *1) kcal/h 2,000 2,500 3,300 3,800 4,500
Btu/h 7,800 9,900 13,000 15,000 17,700
Nominal Cooling kW 2.2 2.8 3.6 4.3 5.0
Capacity *2) kcal/h 1,900 2,400 3,100 3,700 4,300
Btu/h 7,500 9,600 12,300 14,700 17,100

Cooling Power Consumption kW 0.11 0.11 0.15 0.15 0.15


Nominal Heating kW 2.8 3.3 4.2 4.9 5.6
Capacity kcal/h 2,400 2,800 3,600 4,200 4,800
Btu/h 9,600 11,300 14,300 16,700 19,100

Heating Power Consumption kW 0.11 0.11 0.15 0.15 0.15


Sound Pressure Level
(Overall A Scale) dB 30-26-24 30-26-24 32-30-28 32-30-28 33-31-29
Outer Dimensions
Height mm 270 270 270 270 270
(in.) (10-5/8) (10-5/8) (10-5/8) (10-5/8) (10-5/8)
Width mm 650+75 650+75 650+75 650+75 900+75
(in.) (25-9/16+2-15/16) (25-9/16+2-15/16) (25-9/16+2-15/16) (25-9/16+2-15/16) (35-7/16+2-15/16)
Depth mm 720 720 720 720 720
(in.) (28-3/8) (28-3/8) (28-3/8) (28-3/8) (28-3/8)
Net Weight kg 25 25 25 25 34
(lbs.) (55) (55) (55) (55) (75)
Refrigerant — R410A(Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 480/420/360 480/420/360 780/660/540 780/660/540 900/780/660
(Hi/Me/Lo) (cfm) (283/247/212) (283/247/212) (459/388/212) (459/388/212) (530/459/358)

External Pressure *3) Pa 30 30 30 30 30


Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35
(in.) (1/4) (1/4) (1/4) (1/4) (1/4)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
(in.) (1/2) (1/2) (1/2) (1/2) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.21 0.21 0.21 0.21 0.27

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

3
Indoor Unit Type Ceiling Ducted Type (Low Static Pressure)
Model AC 1 , 220-240V/50Hz AVD-18UXCSBL AVD-22UXCSBL AVD-24UXCSBL AVD-27UXCSCL AVD-30UXCSCL
Power Supply AC 1 , 220V/60Hz AVD-18UX2SBL AVD-22UX2SBL AVD-24UX2SBL AVD-27UX2SCL AVD-30UX2SCL
Nominal Cooling kW 5.8 6.5 7.3 8.7 9.3
Capacity *1) kcal/h 5,000 5,600 6,300 7,500 8,000
Btu/h 19,800 22,200 24,900 29,700 31,700
Nominal Cooling kW 5.6 6.3 7.1 8.4 9.0
Capacity *2) kcal/h 4,800 5,400 6,100 7,200 7,700
Btu/h 19,100 21,500 24,200 28,700 30,700

Cooling Power Consumption kW 0.15 0.15 0.19 0.30 0.30


Nominal Heating kW 6.5 7.5 8.5 9.6 10.0
Capacity kcal/h 5,600 6,500 7,300 8,300 8,600
Btu/h 22,200 25,600 29,000 32,800 34,100

Heating Power Consumption kW 0.15 0.15 0.19 0.30 0.30


Sound Pressure Level
(Overall A Scale) dB 33-31-29 34-32-30 34-32-30 38-34-30 38-34-30
Outer Dimensions
Height mm 270 270 270 350 350
(in.) (10-5/8) (10-5/8) (10-5/8) (13-3/4) (13-3/4)
Width mm 900+75 900+75 900+75 900+75 900+75
(in.) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16)
Depth mm 720 720 720 800 800
(in.) (28-3/8) (28-3/8) (28-3/8) (31-1/2) (31-1/2)
Net Weight kg 34 34 34 44 44
(lbs.) (75) (75) (75) (97) (97)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 900/780/660 960/840/720 960/840/720 1550/1350/1150 1550/1350/1150
(Hi/Me/Lo) (cfm) (530/459/388) (565/494/424) (565/494/424) (911/794/676) (911/794/676)

External Pressure *3) Pa 30 30 30 60 60


Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ9.53 Φ9.53 Φ9.53 Φ9.53
(in.) (1/4) (3/8) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
(in.) (5/8) (5/8) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.27 0.27 0.27 0.38 0.38
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

4
Indoor Unit Type Ceiling Ducted Type (Low Static Pressure)
Model AC 1 , 220-240V/50Hz AVD-38UXCSCL AVD-48UXCSDL AVD-54UXCSDL AVD-76UX6SEL *4) AVD-96UX6SFL *4)
Power Supply AC 1 , 220V/60Hz AVD-38UX2SCL AVD-48UX2SDL AVD-54UX2SDL AVD-76UX7SEL *5) AVD-96UX7SFL *5)
Nominal Cooling kW 11.6 14.5 16.5 23.2 28.6
Capacity *1) kcal/h 10,000 12,500 14,200 20,000 24,600
Btu/h 39,600 49,500 56,300 79,200 97,600
Nominal Cooling kW 11.2 14.2 16.0 22.4 28.0
Capacity *2) kcal/h 9,600 12,200 13,800 19,300 24,100
Btu/h 38,200 48,500 54,600 76,500 95,600

Cooling Power Consumption kW 0.30 0.43 0.43 0.95 1.12


Nominal Heating kW 13.0 16.3 18.0 25.0 31.5
Capacity kcal/h 11,200 14,000 15,500 21,500 27,100
Btu/h 44,400 55,600 61,400 85,300 107,500

Heating Power Consumption kW 0.30 0.43 0.43 0.95 1.12


Sound Pressure Level
(Overall A Scale) dB 39-35-31 41-38-33 43-39-34 50 52
Outer Dimensions
Height mm 350 350 350 470 470
(in.) (13-3/4) (13-3/4) (13-3/4) (18-1/2) (18-1/2)
Width mm 900+75 1,300+75 1,300+75 1,060 1,250
(in.) (35-7/16+2-15/16) (51-3/16+2-15/16) (51-3/16+2-15/16) (41-3/4) (49-1/4)
Depth mm 800 800 800 1,120 1,120
(in.) (31-1/2) (31-1/2) (31-1/2) (44-1/12) (44-1/12)
Net Weight kg 44 56 56 94 106
(lbs.) (97) (123) (123) (207) (234)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 1550/1350/1150 2150/1800/1500 2200/1900/1500 3480 4320
(Hi/Me/Lo) (cfm) (911/794/676) (1,264/1,058/882) (1,294/1,117/882) (2048) (2542)

External Pressure *3) Pa 60 60 60 100 100


Connections Flare-Nut Connection (with Flare Nuts) Brazing
Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53
(in.) (3/8) (3/8) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
(in.) (5/8) (5/8) (5/8) (3/4) (7/8)
Condensate Drain — VP25 VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.38 0.52 0.52 0.90 1.06
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.
4. *4) AC 3 , 380~415V/50Hz, *5) AC 3 , 380V/60Hz

5
Indoor Unit Type Ceiling Ducted Type (High Static Pressure)
Model AC 1 , 220-240V/50Hz AVD-07UXCSAH AVD-09UXCSAH AVD-12UXCSAH AVD-14UXCSAH AVD-17UXCSBH
Power Supply AC 1 , 220V/60Hz AVD-07UX2SAH AVD-09UXC2AH AVD-12UX2SAH AVD-14UX2SAH AVD-17UX2SBH
Nominal Cooling kW 2.3 2.9 3.8 4.4 5.2
Capacity *1) kcal/h 2,000 2,500 3,300 3,800 4,500
Btu/h 7,800 9,900 13,000 15,000 17,700
Nominal Cooling kW 2.2 2.8 3.6 4.3 5.0
Capacity *2) kcal/h 1,900 2,400 3,100 3,700 4,300
Btu/h 7,500 9,600 12,300 14,700 17,100

Cooling Power Consumption kW 0.11 0.11 0.15 0.15 0.15


Nominal Heating kW 2.8 3.3 4.2 4.9 5.6
Capacity kcal/h 2,400 2,800 3,600 4,200 4,800
Btu/h 9,600 11,300 14,300 16,700 19,100

Heating Power Consumption kW 0.11 0.11 0.15 0.15 0.15


Sound Pressure Level
(Overall A Scale) dB 33-31-29 33-31-29 33-31-29 33-31-29 34-32-30
Outer Dimensions
Height mm 270 270 270 270 270
(in.) (10-5/8) (10-5/8) (10-5/8) (10-5/8) (10-5/8)
Width mm 650+75 650+75 650+75 650+75 900+75
(in.) (25-9/16+2-15/16) (25-9/16+2-15/16) (25-9/16+2-15/16) (25-9/16+2-15/16) (35-7/16+2-15/16)
Depth mm 720 720 720 720 720
(in.) (28-3/8) (28-3/8) (28-3/8) (28-3/8) (28-3/8)
Net Weight kg 25 25 25 25 34
(lbs.) (55) (55) (55) (55) (75)
Refrigerant — R410A(Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 480/420/360 480/420/360 780/660/540 780/660/540 900/780/660
(Hi/Me/Lo) (cfm) (283/247/212) (283/247/212) (459/388/212) (459/388/212) (530/459/358)

External Pressure *3) Pa 50(80) 50(80) 50(80) 50(80) 50(80)


Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35
(in.) (1/4) (1/4) (1/4) (1/4) (1/4)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
(in.) (1/2) (1/2) (1/2) (1/2) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.21 0.21 0.21 0.21 0.27
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

6
Indoor Unit Type Ceiling Ducted Type (High Static Pressure)
Model AC 1 , 220-240V/50Hz AVD-18UXCSBH AVD-22UXCSBH AVD-24UXCSBH AVD-27UXCSCH AVD-30UXCSCH
Power Supply AC 1 , 220V/60Hz AVD-18UX2SBH AVD-22UX2SBH AVD-24UX2SBH AVD-27UX2SCH AVD-30UX2SCH
Nominal Cooling kW 5.8 6.5 7.3 8.7 9.3
Capacity *1) kcal/h 5,000 5,600 6,300 7,500 8,000
Btu/h 19,800 22,200 24,900 29,700 31,700
Nominal Cooling kW 5.6 6.3 7.1 8.4 9.0
Capacity *2) kcal/h 4,800 5,400 6,100 7,200 7,700
Btu/h 19,100 21,500 24,200 28,700 30,700

Cooling Power Consumption kW 0.15 0.15 0.19 0.30 0.30


Nominal Heating kW 6.5 7.5 8.5 9.6 10.0
Capacity kcal/h 5,600 6,500 7,300 8,300 8,600
Btu/h 22,200 25,600 29,000 32,800 34,100

Heating Power Consumption kW 0.15 0.15 0.19 0.30 0.30


Sound Pressure Level
(Overall A Scale) dB 34-32-30 36-34-32 36-34-32 41-39-34 41-39-34
Outer Dimensions
Height mm 270 270 270 350 350
(in.) (10-5/8) (10-5/8) (10-5/8) (13-3/4) (13-3/4)
Width mm 900+75 900+75 900+75 900+75 900+75
(in.) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16)
Depth mm 720 720 720 800 800
(in.) (28-3/8) (28-3/8) (28-3/8) (31-1/2) (31-1/2)
Net Weight kg 34 34 34 44 44
(lbs.) (75) (75) (75) (97) (97)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 900/780/660 960/840/720 960/840/720 1600/1400/1150 1600/1400/1150
(Hi/Me/Lo) (cfm) (530/459/388) (565/494/424) (565/494/424) (941/823/676) (941/823/676)

External Pressure *3) Pa 50(80) 50(80) 50(80) 120(90) 120(90)


Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ9.53 Φ9.53 Φ9.53 Φ9.53
(in.) (1/4) (3/8) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
(in.) (5/8) (5/8) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.27 0.27 0.27 0.38 0.38
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

7
Indoor Unit Type Ceiling Ducted Type (High Static Pressure)
Model AC 1 , 220-240V/50Hz AVD-38UXCSCH AVD-48UXCSDH AVD-54UXCSDH AVD-76UX6SEH *4) AVD-96UX6SFH *4)
Power Supply AC 1 , 220V/60Hz AVD-38UX2SCH AVD-48UX2SDH AVD-54UX2SDH AVD-76UX7SEH *5) AVD-96UX7SFH *5)
Nominal Cooling kW 11.6 14.5 16.5 23.2 28.6
Capacity *1) kcal/h 10,000 12,500 14,200 20,000 24,600
Btu/h 39,600 49,500 56,300 79,200 97,600
Nominal Cooling kW 11.2 14.2 16.0 22.4 28.0
Capacity *2) kcal/h 9,600 12,200 13,800 19,300 24,100
Btu/h 38,200 48,500 54,600 76,500 95,600

Cooling Power Consumption kW 0.30 0.43 0.43 1.08 1.34


Nominal Heating kW 13.0 16.3 18.0 25.0 31.5
Capacity kcal/h 11,200 14,000 15,500 21,500 27,100
Btu/h 44,400 55,600 61,400 85,300 107,500

Heating Power Consumption kW 0.30 0.43 0.43 1.08 1.34


Sound Pressure Level
(Overall A Scale) dB 43-40-36 44-41-36 45-42-48 52 54
Outer Dimensions
Height mm 350 350 350 470 470
(in.) (13-3/4) (13-3/4) (13-3/4) (18-1/2) (18-1/2)
Width mm 900+75 1,300+75 1,300+75 1,060 1,250
(in.) (35-7/16+2-15/16) (51-3/16+2-15/16) (51-3/16+2-15/16) (41-3/4) (49-1/4)
Depth mm 800 800 800 1,120 1,120
(in.) (31-1/2) (31-1/2) (31-1/2) (44-1/12) (44-1/12)
Net Weight kg 44 56 56 94 106
(lbs.) (97) (123) (123) (207) (234)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 1600/1400/1150 2100/1750/1450 2150/1900/1620 3480 4320
(Hi/Me/Lo) (cfm) (941/823/676) (1,235/1,029/853) (1,264/1,117/953) (2048) (2542)

External Pressure *3) Pa 120(90) 120(90) 120(90) 220 220


Connections Flare-Nut Connection (with Flare Nuts) Brazing
Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53
(in.) (3/8) (3/8) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
(in.) (5/8) (5/8) (5/8) (3/4) (7/8)
Condensate Drain — VP25 VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.38 0.52 0.52 0.90 1.06
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.
4. *4) AC 3 , 380~415V/50Hz, *5) AC 3 , 380V/60Hz

8
Indoor Unit Type Ceiling Ducted Type (High Static Pressure)
Model
AC 1 , 208~230V/60Hz AVD-76UX2SFH AVD-96UX2SFH
Power Supply
Nominal Cooling kW 23.2 28.6
Capacity *1) kcal/h 20,000 24,600
Btu/h 79,200 97,600
Nominal Cooling kW 22.4 28.0
Capacity *2) kcal/h 19,300 24,100
Btu/h 76,500 95,600

Cooling Power Consumption kW 1.42 1.46


Nominal Heating kW 25.0 31.5
Capacity kcal/h 21,500 27,100
Btu/h 85,300 107,500

Heating Power Consumption kW 1.42 1.46


Sound Pressure Level
(Overall A Scale) dB 52 54
Outer Dimensions
Height mm 470 470
(in.) (18-1/2) (18-1/2)
Width mm 1,250 1,250
(in.) (49-1/4) (49-1/4)
Depth mm 1,120 1,120
(in.) (44-1/12) (44-1/12)
Net Weight kg 118 118
(lbs.) (259) (259)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 4000 4320
(Hi/Me/Lo) (cfm) (2353) (2541)

External Pressure *3) Pa 240 200


Connections Brazing
Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53
(in.) (3/8) (3/8)
Gas Line mm Φ19.05 Φ22.2
(in.) (3/4) (7/8)
Condensate Drain — VP25 VP25
Approximate
Packing Measurement m3 1.06 1.06
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

9
5.2 Dimensional Data

Models: AVD- 07~54*

l -φ 6
b (Around the Flange)
40 a Unit:mm
e c x 300 = d
300 4 - 40 x 12
20

(for Suspension Bolt)


Air Inlet
30
22

x
m

22
n

Remote Control Switch g


33.5

Viewed from A
22
30

120
20

300 l - φ6
e (Around the Flange) Drain Pipe Connection Drain Pipe Connection
c x 300 = d
(Standard Position) (VP25) (Optional Drain-Up Mechanism)

Refrigerant Gas Pipe Connection


(With φi Flare Nut)
Air Outlet
Refrigerant Liquid Pipe Connection
a u

2xv=w
75(Electrical Control Box) (With φh Flare Nut) 45
2x90=180
220

A
q

90

v
r
97
p

23

35
s
t

48.5 f j (Refrigerant Gas Pipe Connection) 246(Refrigerant Liquid Pipe Connection)


90(Drain Pipe Connection) 321(Refrigerant Gas Pipe Connection)
k (Refrigerant Liquid Pipe Connection) 377
402

Dimension
Model a b c d e f g h i j k l
07~14 650 730 1 300 215 553 583 6.35 12.7 70 92 10
17/18 900 980 2 600 190 803 833 6.35 15.88 77 92 12
22/24 900 980 2 600 190 803 833 9.53 15.88 77 95 12
27/30 900 980 2 600 190 803 833 9.53 15.88 78 95 12
38 900 980 2 600 190 803 833 9.53 15.88 81 95 12
48/54 1300 1380 3 900 240 1203 1233 9.53 15.88 81 95 14

Dimension
Model m n p q r s t u v w x
07~24 676 720 23 270 182 222 43 220 100 200 226
27~54 756 800 103 350 204 244 123 300 140 280 306

10
Models: AVD-76/96*, AVD-76UX 2SFH, AVD-96UX 2SFH

Air Outlet

Unit:mm
(Around the Flange)
Viewed from A
(for Suspension Bolt)

916

Air Outlet

(Around the Flange)


Air Inlet
Refrigerant Liquid Pipe
9.53 Brazing
Drain Piping Refrigerant Gas Pipe
Air Inlet
22.2(19.05)Brazing
470

NOTES: Data in the bracket is for AVD-76* model.

Data of AVD-76UX2SFH ,AVD-96UX2SFH and AVD-96* is the same.

11
5.3 Selection Data
● Operation Space
Models:AVD-07~54*

Electrical Box Service Access


Door (Min. 450)
Service Space
100 Rear Side of False Ceiling 600
In case that the

1000
ceiling board can

Min.
not be detected

400
Rear Side
for servicing,
prepare a service
access door
below the indoor
275

unit for removing


the indoor unit.
Front Side
Front Side (130)
35

1000
Min.
View from Bottom Min.
Min. 600
600
View from Top

Models: AVD-76/96*

Service Space

Min. 20
730

800
0
~20
200 150
~30
0

Min. 20
600 50
50
Service Access Panel Ceiling
Secure the service space
600 of false ceiling for cleaning
the heat exchanger. * Prepare the Service Access Panel for service.
Service Access Panel * In case that the ceiling board is not be detachable
for servicing, prepare a service access panel below
the indoor unit for removing the indoor unit.

12
● Sensible Heat Factor (SHF)
The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.
SHF
Indoor Unit Model
Hi Me Lo
AVD-07* 0.81 0.69 0.68
AVD-09* 0.81 0.69 0.68
AVD-12* 0.73 0.69 0.65
AVD-14* 0.73 0.69 0.65
AVD-17* 0.75 0.71 0.68
AVD-18* 0.74 0.70 0.67
AVD-22* 0.71 0.69 0.67
AVD-24* 0.70 0.68 0.66
AVD-27* 0.70 0.68 0.66
AVD-30* 0.70 0.68 0.66
AVD-38* 0.72 0.69 0.62
AVD-48* 0.71 0.68 0.62
AVD-54* 0.70 0.68 0.63
AVD-76* (76UX2SFH) 0.71 (0.80 ) ─ ─
AVD-96*( 96UX2SFH) 0.70 ( 0.82 ) ─ ─

13
● Fan Performance
Ceiling Ducted Type (Low Static Pressure)

AVD-07UX*AL AVD-09UX*AL
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)


Me Hi Me Hi
Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVD-12UX*AL AVD-14UX*AL
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

Me Hi Me Hi
Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

14
AVD-17UX*BL AVD-18UX*BL

EXTERNAL STATIC PRESSURE (Pa)


EXTERNAL STATIC PRESSURE (Pa)

Me Hi
Me Hi
Lo
Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVD-22UX*BL AVD-24UX*BL
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

Me Hi
Me Hi
Lo
Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

15
AVD-27UX*CL AVD-30UX*CL
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)


Me Hi Me Hi
Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVD-38UX*CL AVD-48UX*DL
EXTERNAL STATIC PRESSURE (Pa)
EXTERNAL STATIC PRESSURE (Pa)

Me Hi Hi
Me
Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

16
AVD-54UX*DL

120

100
EXTERNAL STATIC PRESSURE (Pa)

80

60 Me Hi
Lo

40

20

0
20 26 32 38 44
AIR VOLUME (m3/min)

AVD-76UX6(7)SEL AVD-96UX6(7)SFL

140 140

130 130

120 120
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

110 110

100 100

90 90

80 80

70 70

60 60

50 50
54 56 58 60 62 60 65 70 75 80

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

17
Ceiling Ducted Type (High Static Pressure)

AVD-07UX*AH AVD-09UX*AH
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)


Hi (Optional Hi (Optional
Pressure Setting) Pressure Setting)

Hi (Standard Hi (Standard
Pressure Setting) Pressure Setting)

Me Me

Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVD-12UX*AH AVD-14UX*AH
EXTERNAL STATIC PRESSURE (Pa)
EXTERNAL STATIC PRESSURE (Pa)

Hi (Optional Hi (Optional
Pressure Setting) Pressure Setting)

Hi (Standard Hi (Standard
Pressure Setting) Pressure Setting)

Me Me

Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

18
AVD-17UX*BH AVD-18UX*BH

EXTERNAL STATIC PRESSURE (Pa)


EXTERNAL STATIC PRESSURE (Pa)

Hi (Optional Hi (Optional
Pressure Setting) Pressure Setting)

Hi (Standard Hi (Standard
Pressure Setting) Pressure Setting)

Me Me

Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVD-22UX*BH AVD-24UX*BH
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

Hi (Optional Hi (Optional
Pressure Setting) Pressure Setting)

Hi (Standard Hi (Standard
Pressure Setting) Pressure Setting)

Me Me

Lo Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

19
AVD-27/30UX*CH AVD-38UX*CH
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)


Hi (Standard Hi (Standard
Pressure Setting) Pressure Setting)

Hi (Optional
Pressure Setting) Hi (Optional
Pressure Setting)

Me
Me

Lo
Lo

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVD-48UX*DH AVD-54UX*DH
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

Hi (Standard
Hi (Standard Pressure Setting)
Pressure Setting)

Hi (Optional Hi (Optional
Pressure Setting) Pressure Setting)

Me Me

Lo
Lo

AIR VOLUME (m3/min)

AIR VOLUME (m3/min)

20
AVD-76UX*FH AVD-96UX*FH
320 320

300 300

280 280

EXTERNAL STATIC PRESSURE (Pa)


EXTERNAL STATIC PRESSURE (Pa)

260 260

240 240

220 220

200 200

180 180

160 160

140 140
61 63 65 67 69 71 73 61 63 65 67 69 71 73

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVD-76UX(6/7)SEH AVD-96UX(6/7)SFH
280 280

260 260

240 240
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

220 220

200 200

180 180

160 160

140 140

120 120

100 100
50 55 60 65 70 75 60 65 70 75 80 85
AIR VOLUME (m3/min) AIR VOLUME (m3/min)

21
Sound Data

Ceiling Ducted Type (Low Static Pressure)

Model: AVD-07/09UX*AL Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-12UX*AL Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Hi
Me
Hi
Me
Lo

Approximate Lo Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVD-14UX*AL Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-17UX*BL Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)
Octave Sound Pressure Level(dB: Overall C Scale)

Hi
Hi
Me
Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

22
Model: AVD-18UX*BL Power Supply: 220-240V/50Hz,220V/60Hz Model:AVD-22/24UX*BL Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Hi
Hi
Me Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVD-27/30UX*CL Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-38UX*CL Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

Hi
Hi
Me
Me

Lo
Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

23
Model: AVD-48UX*DL Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-54UX*DL Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve

Octave Sound Pressure Level(dB: Overall C Scale)


Octave Sound Pressure Level(dB: Overall C Scale)

Hi Hi
Me Me

Lo
Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVD-76UX(6/7)SEL Power Supply: 380~415V/50Hz, 380V/60Hz Model: AVD-96UX(6/7)SFL Power Supply: 380~415V/50Hz, 380V/60Hz
Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)
Octave Sound Pressure Level(dB: Overall C Scale)

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

24
Ceiling Ducted Type (High Static Pressure)

Model:AVD-07/09UX*AH Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-12UX*AH Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Hi
Hi
Me
Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVD-14UX*AH Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-17UX*BH Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)
Octave Sound Pressure Level(dB: Overall C Scale)

Hi Hi
Me Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

25
Model: AVD-18UX*BH Power Supply: 220-240V/50Hz,220V/60Hz Model:AVD-22/24UX*BH Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Hi Hi
Me Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model:AVD-27/30UX*CH Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-38UX*CH Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
Octave Sound Pressure Level(dB: Overall C Scale)
Octave Sound Pressure Level(dB: Overall C Scale)

Hi
Hi
Me
Me

Lo
Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

26
Model: AVD-48UX*DH Power Supply: 220-240V/50Hz,220V/60Hz Model: AVD-54UX*DH Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Hi Hi

Me Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVD-76UX(6/7)SEH Power Supply: 380~415V/50Hz, 380V/60Hz Model: AVD-96UX(6/7)SFH Power Supply: 380~415V/50Hz, 380V/60Hz
Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)
Octave Sound Pressure Level(dB: Overall C Scale)

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

27
Model: AVD-76UX*FH Power Supply: 208~230V/60Hz Model: AVD-96UX*FH Power Supply: 208~230V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve

Octave Sound Pressure Level(dB: Overall C Scale)


Octave Sound Pressure Level(dB: Overall C Scale)

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

28
5.4 Component Data

Indoor Heat Exchanger and Fan


Model AVD-07UX*AL AVD-09UX*AL AVD-12UX*AL AVD-14UX*AL AVD-17UX*BL
Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows - 2 2 3 3 2
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.14 0.14 0.14 0.14 0.21
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1 1 2
Outer Diameter mm 186 186 186 186 186
Revolution (220V) rpm 890/755/635 890/755/635 1,050/900/750 1,050/900/750 990/835/700
Nominal Air Flow m /h
3
480/420/360 480/420/360 780/660/540 780/660/540 900/780/660
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 20 20 40 40 45
Quantity - 1 1 1 1 1
Insulation Class - B B B B B

Model AVD-18UX*BL AVD-22UX*BL AVD-24UX*BL AVD-27UX*CL AVD-30UX*CL


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows - 2 3 3 2 2
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.21 0.21 0.21 0.29 0.29
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2 2 2
Outer Diameter mm 186 186 186 204 204
Revolution (220V) rpm 990/835/700 990/835/700 990/835/700 1,170/1,000/8251,170/1,000/825
Nominal Air Flow m3/h 900/780/660 960/840/720 960/840/720 1550/1350/11501550/1350/1150
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 45 45 45 100 100
Quantity - 1 1 1 1 1
Insulation Class - B B B B B

29
Indoor Heat Exchanger and Fan

Model AVD-38UX*CL AVD-48UX*DL AVD-54UX*DL AVD-76UX*EL AVD-96UX*FL


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 9.53 9.53
Rows - 3 3 3 3 3
Fin Material Aluminum
Pitch mm 1.8 1.8 1.6 1.9 1.9
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.29 0.46 0.46 0.51 0.62
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2 2 2
Outer Diameter mm 204 204 204 280 280
Revolution (220V) rpm 1,170/1,000/825 1,190/1,005/835 1,200/980/850 1,250 1,270
Nominal Air Flow m3/h 1550/1350/1150 2150/1800/1500 2200/1900/1500 3480 4320
Indoor Fan Motor Drip-Proof Type Enclosure PSC
Starting Method - (Permanent Split Capacitor)
Nominal Output W 100 140 180 500 630
Quantity - 1 1 1 1 1
Insulation Class - B F F F F

Model AVD-07UX*AH AVD-09UX*AH AVD-12UX*AH AVD-14UX*AH AVD-17UX*BH


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows - 2 2 3 3 2
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.14 0.14 0.14 0.14 0.21
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1 1 2
Outer Diameter mm 186 186 186 186 186
Revolution (220V) rpm 890/755/635 890/755/635 1050/900/750 1050/900/750 990/835/700
Nominal Air Flow m3/h 480/420/360 480/420/360 780/660/540 780/660/540 900/780/660
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 35 35 80 80 75
Quantity - 1 1 1 1 1
Insulation Class - B B B B B

30
Indoor Heat Exchanger and Fan
Model AVD-18UX*BH AVD-22UX*BH AVD-24UX*BH AVD-27UX*CH AVD-30UX*CH
Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows - 2 3 3 2 2
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.21 0.21 0.21 0.29 0.29
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2 2 2
Outer Diameter mm 186 186 186 204 204
Revolution (220V) rpm 990/835/700 990/835/700 990/835/700 1170/1000/825 1170/1000/825
Nominal Air Flow m3 /h 900/780/660 960/840/720 960/840/720 1600/1400/1150 1600/1400/1150
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 75 75 75 120 120
Quantity - 1 1 1 1 1
Insulation Class - B B B F F

Model AVD-38UX*CH AVD-48UX*DH AVD-54UX*DH AVD-76UX*EH AVD-96UX*FH


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 9.53 9.53
Rows - 3 3 3 3 3
Fin Material Aluminum
Pitch mm 1.8 1.8 1.6 1.9 1.9
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.29 0.46 0.46 0.51 0.62
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2 2 2
Outer Diameter mm 204 204 204 280 280
Revolution (220V) rpm 1170/1000/825 1190/1005/835 1200/980/850 1250* 1270*
Nominal Air Flow m3/h 1600/1400/1150 2100/1750/1450 2150/1800/1550 3480 4320
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 120 200 250 650 990
Quantity - 1 1 1 1 1
Insulation Class - F F F F F

*: For 380V

31
Model AVD-76UX2SFH AVD-96UX2SFH
Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 9.53 9.53
Rows - 3 3
Fin Material Aluminum
Pitch mm 1.8 1.9
Maximum Operating Pressure MPa 4.15 4.15
Total Face Area m2 0.56 0.62
Number of Coil/Unit - 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2
Outer Diameter mm 250 250
Revolution (220V) rpm 1320 1320
Nominal Air Flow m3/h 4000 4320
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 530+530 530+530
Quantity - 2 2
Insulation Class - F F

32
5.5 Control System
Refrigeration Cycle

For Ceiling Ducted Type (05~54 Model)

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

33
For Ceiling Ducted Type (76 and 96 Model)

Indoor Unit

: Refrigerant Flow Direction (Cooling)


: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
: Brazing
2

3
1

S
4
b

4
Refrigerant Liquid Pipe Connection
S
3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

34
5.6 Electrical Data

< 50 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVD-07UXCSAL 0.53 0.11
AVD-09UXCSAL 0.53 0.11
AVD-12UXCSAL 0.75 0.15
AVD-14UXCSAL 0.75 0.15
AVD-17UXCSBL 0.77 0.15
AVD-18UXCSBL 0.77 0.15
Ceiling Ducted AVD-22UXCSBL 220~240 1 50 264 198 1 0.77 0.15
Type (Low Static AVD-24UXCSBL 0.96 0.19
Pressure) AVD-27UXCSCL 1.55 0.30
AVD-30UXCSCL 1.55 0.30
AVD-38UXCSCL 1.55 0.30
AVD-48UXCSDL 2.19 0.43
AVD-54UXCSDL 2.19 0.43
AVD-76UXCSEL 1.71 0.95
380~415 3 50 457 342 3
AVD-96UXCSFL 2.03 1.12
AVD-07UXCSAH 0.53 0.11
AVD-09UXCSAH 0.53 0.11
AVD-12UXCSAH 0.75 0.15
AVD-14UXCSAH 0.75 0.15
AVD-17UXCSBH 0.77 0.15
AVD-18UXCSBH 0.77 0.15
Ceiling Ducted AVD-22UXCSBH 220~240 1 50 264 198 1 0.77 0.15
Type (High Static AVD-24UXCSBH 0.96 0.19
Pressure) AVD-27UXCSCH 1.55 0.30
AVD-30UXCSCH 1.55 0.30
AVD-38UXCSCH 1.55 0.30
AVD-48UXCSDH 2.19 0.43
AVD-54UXCSDH 2.19 0.43
AVD-76UXCSEH 1.96 1.03
380~415 3 50 457 342 3
AVD-96UXCSFH 2.43 1.28

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

35
< 60 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVD-07UX2SAL 0.53 0.1
AVD-09UX2SAL 0.53 0.1
AVD-12UX2SAL 0.75 0.14
AVD-14UX2SAL 0.75 0.14
AVD-17UX2SBL 0.77 0.14
AVD-18UX2SBL 0.77 0.14
Ceiling Ducted AVD-22UX2SBL 0.77 0.14
Type (Low Static AVD-24UX2SBL 220 1 60 242 198 1 0.96 0.18
Pressure) AVD-27UX2SCL 1.55 0.29
AVD-30UX2SCL 1.55 0.29
AVD-38UX2SCL 1.55 0.29
AVD-48UX2SDL 2.19 0.41
AVD-54UX2SDL 2.19 0.41
AVD-76UX7SEL 1.71 0.9
380 3 60 418 342 3
AVD-96UX7SFL 2.03 1.07
AVD-07UX2SAH 0.53 0.1
AVD-09UX2SAH 0.53 0.1
AVD-12UX2SAH 0.75 0.14
AVD-14UX2SAH 0.75 0.14
AVD-17UX2SBH 0.77 0.14
AVD-18UX2SBH 0.77 0.14
Ceiling Ducted AVD-22UX2SBH 0.77 0.14
Type (High Static AVD-24UX2SBH 220 1 60 242 198 1 0.96 0.18
Pressure) AVD-27UX2SCH 1.55 0.29
AVD-30UX2SCH 1.55 0.29
AVD-38UX2SCH 1.55 0.29
AVD-48UX2SDH 2.19 0.41
AVD-54UX2SDH 2.19 0.41
AVD-76UX7SEH 1.96 1.03
380 3 60 418 342 3
AVD-96UX7SFH 2.43 1.28
AVD-76UX2SFH 6.62 1.42
208~230 1 60 253 187 1
AVD-96UX2SFH 6.8 1.46

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

36
Safety and Control Device Setting
Indoor Unit

AVD-07~96*
Model

For Evaporator Fan


℃ 130±5
Motor Thermostat Cut-Out
Cut-In ℃ 83±15
For Control Circuit
Fuse Capacity A 5

Freeze Protection
Thermostat ℃ 0
Cut-Out
Cut-In ℃ 14

Thermostat
Differential ℃ 2

37
5.7 Electrical Wiring Diagram Model: AVD-07~54*L

07~24

27~54

38
Electrical Wiring Diagram Model: AVD-76~96*

39
Electrical Wiring Diagram Model: AVD-07~54*H

07~24

07~24
27~54
27~54

40
5.8 Indoor Unit Optional Parts

Optional Parts Applied Indoor Unit Type


Ceiling Ducted Type Ceiling Ducted Type
Type Model
(Low Static Pressure) (High Static Pressure)
HYXE-F01H ● ●
HYXE-G01H ● ●
Wire Remote Control
Switch HYXE-VA011 ● ●
HYXE-J01H ● ●
HYXE-M01H ● ●
HYXE-S01H ● ●
Wireless Remote Control HYE-L01 ● ●
Switch HYE-W01 ● ●
HYRE-V01H ● ●
HYRE-T01H
Wireless Receiver Kit
HYRE-V02H
HYRE-X01H
7 Day Timer HYDE-E01H ● ●
HYJE-H01H ● ●
HYJE-D02H ● ●
HYJ-J01H ● ●
Centrol Station HCCS-H128H2C1YM ● ●
HCCS-H128H2C1NM ● ●
HCCS-H247R4C1E
HCCS-H128H2C2NM ● ●
Interface for Building HC-A64BNP ● ●
Control HCPC-H2M1C ● ●
HPS-162#E ● ●
Drain Pump HPS-132#E ● ●
HPS-151#E ● ●
HF-224L-FE ●8-10HP
Long Life filter HF-280L-FE ●8-10HP
HF-40L-ZFE
HP-DB-NK
3D Air Swing
HP-EB-NK

41
5.9

For Model:AVD-07~54*

For Model:AVD-76~96*

42
5.10 Installation
5.10.1 Initial Check

AVD-07~54*

AVD-76~96*

600
5.10.2
600

43
● AVD-76~96*

below

AVD-07~54*

07 14

17 24

Fig. Suspension Bolts


27 38
AVD-76~96UX2SFH
Model(103 Btu/h) a b c d e f g h

76
1250 1288 1106 1100 20 1000 21 1050
96
48 54
AVD-76~96UX(6/7)S(E/F)(L/H)
Model3(10 Btu/h) a b c d e f g h

76 1060 1098 916 910 16 800 17 850

96 1250 1288 1106 1100 20 1000 21 1050

44

below Fig

45
Fig. Connecting Supply Duct

5.10.3

10A
AVD-07~54*

07 14
17 18
22 24
27 38
48 54

07 14
17 18
An excess or a shortage of refrigerant is the
22 30
main cause of trouble to the units.
Charge the correct refrigerant quantity. 38 54

46
AVD-76~96* AVD-07~54*

B-
C- A- below.

mm(in.)
(10 3 Btu/h) A B C

76 19.05(3/4) 9.53(3/8)
VP 25 ●
96 22.2(7/8) 9.53(3/8)

below.

Flaring Dimension
Perform the flaring work as shown below.

+0
Diameter A -0.4
R410A R407C
6.35 9.1 9.0
9.53 13.2 13.0
12.7 16.6 16.2
15.88 19.7 19.4
19.05 (*) 23.3
A +0
-0.4

(*)It is impossible to perform the flaring work with
1/2H material. In this case, use an accessory
pipe(with a flare).

AVD-76~96*

47
● 5.10.4

below.

07-14 10 3 Btu/h

17-54 10 3 Btu/h

76-96 103Btu/h

48
5.10.5

below.

49

17~24
27~38
07~14 48~54

Cord Clamp

below.

220-240V~ 50Hz
220V~60Hz

AVD-07~54*

Model Static/Pressure(Pa)
AVD-07~24*L 30(*)
AVD-07~54*L 60(*)
50(*)80
AVD-07~24*H
Printed 1(*)/2
120(*)/90
AVD-27~54*H
Printed 1(*)/2
AVD-76~96UX(6/7)SFL 100(*)
AVD-76~96UX(6/7)SFH 220(*)
AVD-76UX2SFH 240(*)
AVD-96UX2SFH 200(*)

50
AVD-76~96UX2SFH

Printed"2"
Fig. Static Pressure of Change

AVD-76~96UX2SFH,AVD-76~96UX6SE/FL/H

Cord Clamp
Cord Clamp

1PH, 208-230 V 60Hz

AVD-76~96UX(6/7)S(E/F)(L/H)

5.10.6

Cord Clamp

380-415V 3N 50Hz 380V 3N~60Hz

51

Current(A) Wire Size(mm2 )


I≤3 2.5
3<l≤ 6 2.5
6<l≤10 2.5
10<I≤16 4
16<l≤25 6
25<l≤32 10
5.10.7 32<l≤50 16
50<l≤63 25
63<l Ć1

Ć1 In the case that current exceeds 63A, do not


connect cables inseries.
Use an ELB (Electric Leakage Breaker).If not used ,it
will cause an electric shock or a fire.

Run through the cables using conduit tube, and
Completely seal the end of conduit tube with sealing
materials.with sealing materials.

AVD-07~54*

MCA EN60 335-1 EN60 335-1


1 1
AVD-07~09* 1.1A

AVD-12~14* 1.5A
5
AVD-17~22* 1.6A

AVD-24* 1.9A
m2
2.5m 0.75mm2
AVD-27~38* 3.0A

AVD-48~54* 4.2A ①

AVD-76~96UX(6/7)* 10A
2
AVD-76~96UX2SFH 11A 4.0mm 2 0.75mm

Ex.) Set at No.16 Unit


Setting Set by inserting DSW6
The wire sizes marked with *1 in the above table are selected Position Slotted screwdriver
into the groove
at the maximum current of the unit according to the European
Standard, EN60 335-1.Use the wires which are not lighter than
Set No.1 Pin ON
the ordinary polyvinyl chloride sheathed flexible cord Before shipment. DSW6 and RSW1 are set to "0".
(code designation H05VV-F). Max.64 units are available to set when all the equipment
RSW1
to be connected are corresponding to Hi-NET.
3 Max.16 units when the units corresponding/
non-corresponding to Hi-NET are combined. Set at "6"

52
② Setting of (DSW3&DSW4)

AVD-07~54*

AVD-76~96*

Capacity 07 09 12 14 17 18 22

Capacity 24 27 30 38 48 54 76

Capacity 96

53
6. Low-Height Celling Ducted Type(AVE)
6.1 General Data

Indoor unit Low-height Celing Ducted Type


AC 1φ,
Model Power supply AVE-05HCFRL AVE-07HCFRL AVE-09HCFRL AVE-12HCFRL AVE-15HCFRL
220~240V/50Hz
kW 1.7 2.2 2.8 3.6 4.5
Nominal Cooling Capacity kcal/h 1500 1900 2400 3100 3900
Btu/h 5800 7500 9600 12300 15300
kW 1.9 2.5 3.2 4.0 5.0
Nominal Heating Capacity kcal/h 1700 2100 2700 3450 4300
Btu/h 6500 8500 11300 13600 17100
Cooling Power Consumption kW 0.05 0.05 0.07 0.07 0.08
Heating Power Consumption kW 0.05 0.05 0.07 0.07 0.08
Cooling Operating Current A 0.25 0.25 0.35 0.35 0.38
Heating Operating Current A 0.25 0.25 0.35 0.35 0.38
Noise Level(Hi/Me/Lo) Sound Pressure-dB(A) 29/24/22 29/24/22 35/25/23 35/25/23 36/25/23
H(mm) 192 192 192 192 192
Outer Dimensions W(mm) 700 700 700 700 910
D(mm) 447 447 447 447 447
Net Weight kg 16 16 17 17 21
Air Flow Rate(Lo/Me/Hi) m3/h 282/330/420 282/330/420 288/342/540 288/342/540 330/378/720
Motor Power W 14 14 29 29 35
Piping Connections Flare-nut Connection(with Flare Nuts)
Liquid Line mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35
Gas Line mm Ø12.7 Ø12.7 Ø12.7 Ø12.7 Ø12.7
Condensate Drain VP25(Outer Diameter Ø32mm)
Approximate Packing
m3 0.15 0.15 0.15 0.15 0.18
Measurement
External Pressure Pa 10(10-30)

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.4 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

4. The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

54
Indoor unit Low-height Celing Ducted Type
AC 1φ,
Model Power supply AVE-17HCFRL AVE-19HCFRL AVE-22HCFRL AVE-24HCFRL
220~240V/50Hz
kW 5.0 5.6 6.3 7.1
Nominal Cooling Capacity kcal/h 4300 4800 5400 6100
Btu/h 17100 19100 21500 24200
kW 5.6 6.3 7.1 8.0
Nominal Heating Capacity kcal/h 4800 5400 6100 6800
Btu/h 19100 21500 24200 27300
Cooling Power Consumption kW 0.08 0.10 0.12 0.12
Heating Power Consumption kW 0.08 0.10 0.12 0.12
Cooling Operating Current A 0.38 0.46 0.57 0.57
Heating Operating Current A 0.38 0.46 0.57 0.57
Noise Level(Hi/Me/Lo) Sound Pressure-dB(A) 36/25/23 35/25/23 39/26/25 39/26/25
H(mm) 192 192 192 192
Outer Dimensions W(mm) 910 1180 1180 1180
D(mm) 447 447 447 447
Net Weight kg 21 25 26 26
Air Flow Rate(Lo/Me/Hi) m3/h 330/378/720 462/480/810 522/558/1080 522/558/1080
Motor Power W 35 40 60 60
Piping Connections Flare-nut Connection(with Flare Nuts)
Liquid Line mm Ø6.35 Ø6.35 Ø9.53 Ø9.53
Gas Line mm Ø12.7 Ø15.88 Ø15.88 Ø15.88
Condensate Drain VP25(Outer Diameter Ø32mm)
Approximate Packing
m3 0.18 0.22 0.22 0.22
Measurement
External Pressure Pa 10(10-30)

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.4 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

4. The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

55
Indoor unit Low-height Celing Ducted Type
DC 1φ,
Model Power supply AVE-05HJFDL AVE-07HJFDL AVE-09HJFDL AVE-12HJFDL AVE-15HJFDL
220~240V/50Hz(60Hz)
kW 1.7 2.2 2.8 3.6 4.5
Nominal Cooling Capacity kcal/h 1500 1900 2400 3100 3900
Btu/h 5800 7500 9600 12300 15300
kW 1.9 2.5 3.2 4.0 5.0
Nominal Heating Capacity kcal/h 1700 2100 2700 3450 4300
Btu/h 6500 8500 11300 13600 17100
Cooling Power Consumption kW 0.03 0.03 0.05 0.05 0.06
Heating Power Consumption kW 0.03 0.03 0.05 0.05 0.06
Cooling Operating Current A 0.32 0.32 0.43 0.43 0.50
Heating Operating Current A 0.32 0.32 0.43 0.43 0.50
28/27/26 28/27/26 35/32/32 35/32/32 35/32/32
Noise Level Sound Pressure-dB(A)
/24/23/21 /24/23/21 /30/26/23 30/26/23 30/26/23
H(mm) 192 192 192 192 192
Outer Dimensions W(mm) 700 700 700 700 910
D(mm) 447 447 447 447 447
Net Weight kg 16 16 17 17 20
288/318/342/ 288/318/342/ 312/354/402/ 312/354/402/ 330/408/486/
Air Flow Rate m3/h
366/390/420 366/390/420 438/486/540 438/486/540 564/648/720
Motor Power W 40 40 40 40 40
Piping Connections Flare-nut Connection(with Flare Nuts)
Liquid Line mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35
Gas Line mm Ø12.7 Ø12.7 Ø12.7 Ø12.7 Ø12.7
Condensate Drain VP25(Outer Diameter Ø32mm)
Approximate Packing
m3 0.15 0.15 0.15 0.15 0.18
Measurement
External Pressure Pa 10(0-10-30)

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.4 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.
4. The above air flow rate and noise level are tested without filter screen.

56
Indoor unit Low-height Celing Ducted Type
DC 1φ,
Model Power supply AVE-17HJFDL AVE-19HJFDL AVE-22HJFDL AVE-24HJFDL
220~240V/50Hz(60Hz)
kW 5.0 5.6 6.3 7.1

Nominal Cooling Capacity kcal/h 4300 4800 5400 6100

Btu/h 17100 19100 21500 24200

kW 5.6 6.3 7.1 8.0

Nominal Heating Capacity kcal/h 4800 5400 6100 6800

Btu/h 19100 21500 24200 27300

Cooling Power Consumption kW 0.06 0.06 0.09 0.09

Heating Power Consumption kW 0.06 0.06 0.09 0.09

Cooling Operating Current A 0.50 0.50 0.75 0.75

Heating Operating Current A 0.50 0.50 0.75 0.75

Noise Level Sound Pressure-dB(A) 35/32/32/30/26/23 35/32/30/28/25/23 38/36/35/33/31/24 38/36/35/33/31/24

H(mm) 192 192 192 192

Outer Dimensions W(mm) 910 1180 1180 1180

D(mm) 447 447 447 447

Net Weight kg 20 24 24 24

330/408/486/ 462/528/600/ 522/630/738/ 522/630/738/


Air Flow Rate m3/h
564/648/720 672/750/810 858/966/1080 858/966/1080

Motor Power W 40 60 60 60

Piping Connections
Flare-nut Connection(with Flare Nuts)
Liquid Line mm Ø6.35 Ø6.35 Ø9.53 Ø9.53

Gas Line mm Ø12.7 Ø15.88 Ø15.88 Ø15.88

Condensate Drain VP25(Outer Diameter Ø32mm)

Approximate Packing
m3 0.18 0.22 0.22 0.22
Measurement

External Pressure Pa 10(0-10-30)

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.4 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

3. The data for external pressure *3) indicates "Standard Pressure Setting values when a filter is not used.

4.The above air flow rate and noise level are tested without filter screen.

57
6.2 Dimensional Data

■ Low-Height Ceiling Ducted Type

Models: AVE-05~24*

(Suspension Bult Size)


Unit:mm
(Suspension Bult Size)

Model

05 12 751 695

15 17 962 906

19 24 1232 1176

Air Outlet

Liquid Pipe Gas Pipe

63
Drain Pipe (for Drain Pump)

58
6.3 Selection Data

Models: AVE-05~24*

59
● Sensible Heat Factor (SHF)
The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.

SHF
Indoor Unit Model
Hi Me Lo
AVE-05HCFRL 0.82 0.72 0.70
AVE-07HCFRL 0.82 0.72 0.70
AVE-09HCFRL 0.81 0.69 0.68
AVE-12HCFRL 0.77 0.72 0.68
AVE-15HCFRL 0.75 0.71 0.67
AVE-17HCFRL 0.75 0.71 0.67
AVE-19HCFRL 0.74 0.70 0.67
AVE-22HCFRL 0.72 0.70 0.68
AVE-24HCFRL 0.70 0.68 0.66

SHF
Indoor Unit Model
SHi Hi Me Lo SLo Night Shift

AVE-05HJFDL 0.72 0.72 0.68 0.65 0.64 0.63


AVE-07HJFDL 0.72 0.72 0.68 0.65 0.64 0.63
AVE-09HJFDL 0.73 0.72 0.67 0.65 0.63 0.61
AVE-12HJFDL 0.72 0.68 0.67 0.65 0.63 0.61
AVE-15HJFDL 0.72 0.67 0.66 0.64 0.62 0.60
AVE-17HJFDL 0.72 0.67 0.65 0.64 0.62 0.60
AVE-19HJFDL 0.71 0.66 0.64 0.63 0.62 0.60
AVE-22HJFDL 0.71 0.65 0.64 0.63 0.62 0.60
AVE-24HJFDL 0.71 0.63 0.62 0.61 0.61 0.59

60
● Fan Performance
AVE-05HCFRL
AVE-07HCFRL

4. 4.

EXTERNAL STATIC PRESSURE (Pa)


EXTERNAL STATIC PRESSURE (Pa)

3. 3.

2. 2.

1. Hi (Optional) 1. Hi (Optional)

Hi (Standard) Hi (Standard)
0. Me (Optional) 0. Me (Optional)

Me (Standard)
Me (Standard)
/. Lo (Optional) /. Lo (Optional)
Lo (Standard) Lo (Standard)

. .
2 3 4 5 6 2 3 4 5 6

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVE-09HCFRL AVE-12HCFRL

4. 4.
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

3. 3.

2. 2.

1. Hi (Optional) 1. Hi (Optional)

Hi (Standard) Hi (Standard)
0. Me (Optional) 0.
Me (Optional)

Lo (Optional) Lo (Optional)
/. Me (Standard) /. Me (Standard)

Lo (Standard) Lo (Standard)

. .
5 6 7 8 9 5 6 7 8 9
AIR VOLUME (m3/min) AIR VOLUME (m3/min)

The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

61
AVE-15HCFRL AVE-17HCFRL

4. 4.

EXTERNAL STATIC PRESSURE (Pa)


EXTERNAL STATIC PRESSURE (Pa)

3. 3.

2. 2.

1. Hi (Optional) 1. Hi (Optional)

Hi (Standard) Hi (Standard)
0. 0.

Lo (Optional) Me (Optional) Me (Optional)


Lo (Optional)
/. Me (Standard) /. Me (Standard)
Lo (Standard) Lo (Standard)

. .
4 6 8 10 12 4 6 8 10 12
AIR VOLUME (m3/min) AIR VOLUME (m3/min)

AVE-19HCFRL AVE-22HCFRL

4. 4.
EXTERNAL STATIC PRESSURE (Pa)
EXTERNAL STATIC PRESSURE (Pa)

3. 3.

2. 2.

Hi (Optional)
1. Hi (Optional) 1.

Hi (Standard)
Hi (Standard)
0. 0. Me (Optional)
Lo (Optional)

Me (Optional)
Lo (Optional)
Me (Standard) /.
/. Lo (Standard) Me (Standard)
Lo (Standard)

. .
5.5 7,3 9,3 /1,3 13.5 6 9 /2 /5 /8

AIR VOLUME (m3/min) AIR VOLUME (m3/min)

The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

62
AVE-24HCFRL

4.
EXTERNAL STATIC PRESSURE (Pa)

3.

2.

Hi (Optional)
1.

Hi (Standard)
Me (Optional)
0.
Lo (Optional)

/. Lo (Standard)
Me (Standard)

.
6 9 /2 /5 /8

AIR VOLUME (m3/min)

The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

63
AVE-05/07HJFDL AVE-09/12HJFDL
50 70

45
60
EXTERNAL STATIC PRESSURE (Pa)

40

EXTERNAL STATIC PRESSURE (Pa)


SHi
SHi 50
35
Hi
Hi
30
40
Me
Me
25
Lo
30 Lo
20 SLo

SLo
15 20
Night Shift

10 Night Shift

10
5

0 0
0.00 2.00 4.00 6.00 8.00 10.00 0.00 2.00 4.00 6.00 8.00 10.00

AIR VOLUME (m3/min)


AIR VOLUME (m3/min)

AVE-15/17HJFDL AVE-19HJFDL

60 70

60
50
SHi
EXTERNAL STATIC PRESSURE (Pa)

EXTERNAL STATIC PRESSURE (Pa)

Hi 50
40
SHi
Me
40
Hi

30 Lo
Me
30
Lo
SLo
SLo
20
20

Night Shift Night Shift

10 10

0
0 0 5 10 15 20
0 5 10 15
AIR VOLUME (m3/min) AIR VOLUME (m3/min)

The above air flow rate and noise level are tested without filter screen.

64
AVE-22/24HJFDL
80

70

60
SHi
EXTERNAL STATIC PRESSURE (Pa)

Hi
50

Me
40
Lo

30
SLo

20
Night Shift

10

0
0 5 10 15 20 25
AIR VOLUME (m3/min)

The above air flow rate and noise level are tested without filter screen.

65
● Sound Data

Low-height Ceiling Duct Type

Model: AVE-05/07HCFRL Power Supply: 220-240V/50Hz Model: AVE-09/12HCFRL Power Supply: 220-240V/50Hz

Measurement Point: 1.4 Meters Beneath the Unit Measurement Point: 1.4 Meters Beneath the Unit
TO
TO
Noise Criteria Curve

Octave Sound Pressure Level(dB: Overall C Scale)


Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

O
O
ZYNN0
ZYNN0
O ZYNNTT
O ZYNNTT
TO ZYNNTO
TO ZYNNTO
ZYNNTT
ZYNNTT
TO ZYNNTO
TO ZYNNTO
ZYNNTT
ZYNNTT

ZYNNTO TO ZYNNTO
TO
ZYNNRT ZYNNRT
Hi Me
Hi
RO ZYNNRO RO ZYNNRO
Me
ZYNNQT ZYNNQT
QO Approximate
ZYNNQO QO Approximate Lo ZYNNQO
Threshold of Threshold of
Hearing for Lo Hearing for
Continuous Noise Continuous Noise
PO PO
TR PQT QTO TOO POOO QOOO TOOO 8OOO TR PQT QTO TOO POOO QOOO TOOO 8OOO

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVE-15/17HCFRL Power Supply: 220-240V/50Hz Model: AVE-19HCFRL Power Supply: 220-240V/50Hz
Measurement Point: 1.4 Meters Beneath the Unit
Measurement Point: 1.4 Meters Beneath the Unit
TO TO
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

O O
ZYNN0 ZYNN0
O O
ZYNNTT ZYNNTT
TO ZYNNTO TO ZYNNTO
ZYNNTT ZYNNTT
TO ZYNNTO TO ZYNNTO
ZYNNTT ZYNNTT

TO ZYNNTO TO ZYNNTO
ZYNNRT ZYNNRT
Hi Me Hi Me
RO ZYNNRO RO ZYNNRO
ZYNNQT ZYNNQT

QO ZYNNQO QO Lo ZYNNQO
Approximate Lo Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

PO PO
TR PQT QTO TOO POOO QOOO TOOO TR 125 250 500 1000 2000 TOOO 8OOO
8OOO
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

66
Model: AVE-22/24HCFRL Power Supply: 220-240V/50Hz

Measurement Point: 1.4 Meters Beneath the Unit


TO
Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

O
ZYNN0
O
ZYNNTT
TO ZYNNTO
ZYNNTT
TO ZYNNTO
ZYNNTT
TO ZYNNTO
Hi
Me
ZYNNRT
RO ZYNNRO

Lo ZYNNQT
QO Approximate ZYNNQO
Threshold of
Hearing for
Continuous Noise
PO
TR PQT QTO TOO POOO QOOO TOOO 8OOO
Central Frequency(Cycle per Second)

The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

67
Model: AVE-05/07HJFDL Power Supply: 220-240V/50Hz(60Hz) Model: AVE-09/12HJFDL Power Supply: 220-240V/50Hz(60Hz)

Measurement Point: 1.4 Meters Beneath the Unit Measurement Point: 1.4 Meters Beneath the Unit
90
90 Noise Criteria Curve
Noise Criteria Curve
80 80
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


70 70
NC-70 NC-70

NC-65 NC-65
60 60
NC-60 NC-60
NC-55 NC-55
50 50
NC-50 NC-50
night shift SLO LO ME HI
NC-45 SHI NC-45
40 40
night shift SLO LO ME HI NC-40 NC-40
SHI
NC-35 NC-35
30 30
NC-30 NC-30

20 NC-25 20 NC-25
NC-20 NC-20

10 NC-15 10 NC-15
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVE-15HJFDL Model: AVE-17/19HJFDL Power Supply: 220-240V/50Hz(60Hz)


Power Supply: 220-240V/50Hz(60Hz)

Measurement Point: 1.4 Meters Beneath the Unit Measurement Point: 1.4 Meters Beneath the Unit

90 90
Noise Criteria Curve Noise Criteria Curve

80 80
Octave Sound Pressure Level(dB: Overall C Scale)
Octave Sound Pressure Level(dB: Overall C Scale)

70 70
NC-70 NC-70
NC-65
NC-65 60
60 NC-60
NC-60
NC-55
NC-55 50
50 NC-50
night shift NC-50 night shift SLO LO ME HI
SLO LO ME HI SHI NC-45
SHI NC-45 40
40 NC-40
NC-40
NC-35
NC-35 30
30 NC-30
NC-30
20 NC-25
20 NC-25
NC-20
NC-20
10 NC-15
10 NC-15 63 125 250 500 1k 2k 4k 8k
63 125 250 500 1k 2k 4k 8k

Central Frequency(Cycle per Second)


Central Frequency(Cycle per Second)

The above air flow rate and noise level are tested without filter screen.

68
Model: AVE-22/24HJFDL Power Supply: 220-240V/50Hz(60Hz)

Measurement Point: 1.4 Meters Beneath the Unit

90
Noise Criteria Curve
80
Octave Sound Pressure Level(dB: Overall C Scale)

70
NC-70
NC-65
60
NC-60
NC-55
50
night shift
NC-50
SLO LO ME HI
SHI NC-45
40
NC-40
NC-35
30
NC-30

20 NC-25
NC-20
10 NC-15
63 125 250 500 1k 2k 4k 8k

Central Frequency(Cycle per Second)

The above air flow rate and noise level are tested without filter screen.

69
6.4 Component Data

Indoor Heat Exchanger and Fan


Model AVE-05HCFRL AVE-07HCFRL AVE-09HCFRL AVE-12HCFRL AVE-15HCFRL
Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows - 2 2 3 3 3
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.14 0.14 0.14 0.14 0.15
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2 2 2
Outer Diameter mm 134 134 134 134 134

Revolution (220V) rpm 910/750/650 910/750/650 1120/765/680 1120/765/680 1180/700/640

Nominal Air Flow m3/min 7/5.5/4.7 7/5.5/4.7 9/5.7/4.8 9/5.7/4.8 12/6.3/5.5

Indoor Fan Motor Drip-Proof Type Enclosure


Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 15 15 28 28 35
Quantity - 1 1 1 1 1
Insulation Class - B B B B B

Model AVE-17HCFRL AVE-19HCFRL AVE-22HCFRL AVE-24HCFRL


Heat Exchanger Type - M ult i- Pa ss C r o ss Fin ne d Tu b e
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 3 3 3 3
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.15 0.20 0.20 0.20
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 3 3 3
Outer Diameter mm 134 134 134 134
Revolution (220V) rpm 1180/700/640 1020/680/640 1290/730/700 1290/730/700
Nominal Air Flow m3/min 12/6.3/5.5 13.5/8/7.7 18/9.3/8.7 18/9.3/8.7
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 35 40 65 65
Quantity - 1 1 1 1
Insulation Class - B B B B

The above air flow rate and noise level are tested with AC 220V power supply and without filter screen.

70
Indoor Heat Exchanger and Fan

Model AVE-05HJFDL AVE-07HJFDL AVE-09HJFDL AVE-12HJFDL AVE-15HJFDL


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows - 2 2 3 3 3
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.14 0.14 0.14 0.14 0.15
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2 2 2
Outer Diameter mm 134 134 134 134 134
867/820/773 867/820/773 1150/1067/984 1150/1067/984 1138/1034/928
Revolution (220V) rpm
725/678/631 725/678/631 /901/818/735 /901/818/735 /822/716/610
7/6.5/6.1 7/6.5/6.1 9/8.1/7.3/6.7 9/8.1/7.3/6.7 12/10.8/9.4
Nominal Air Flow m3/min
5.7/5.3/4.8 5.7/5.3/4.8 /5.9/5.2 /5.9/5.2 /8.1/6.8/5.5
Indoor Fan Motor IP20
Starting Method - Control software
Nominal Output W 40 40 40 40 40
Quantity - 1 1 1 1 1
Insulation Class - E E E E E

Model AVE-17HJFDL AVE-19HJFDL AVE-22HJFDL AVE-24HJFDL


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 3 3 3 3
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.15 0.2 0.2 0.2
Number of Coil/Unit - 1 1 1 1
Indoor Fan Centrifugal Fan
Number/Unit - 2 3 3 3
Outer Diameter mm 134 134 134 130
Revolution
1138/1034/928 991/917/844 1222/1110/1000 1222/1110/1000
rpm
/822/716/610 /771/698/625 890/780/670 890/780/670
Nominal Air Flow 12/10.8/9.4 13.5/12.5/11.2 18/16.1/14.3 18/16.1/14.3
m3/min
/8.1/6.8/5.5 /10/8.8/7.7 12.3/10.5/8.7 12.3/10.5/8.7
Indoor Fan Motor IP20
Starting Method - Control software
Nominal Output W 40 60 60 60
Quantity - 1 1 1 1
Insulation Class - E E E E

The above air flow rate and noise level are tested without filter screen.

71
6.5 Refrigeration Cycle

05~24Model

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

72
6.6 Electrical Data

< 50 Hz >
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum RNC IPT
AVE-05HCFRL 0.25/0.25 0.05/0.05
AVE-07HCFRL 0.25/0.25 0.05/0.05
AVE-09HCFRL 0.35/0.35 0.07/0.07
AVE-12HCFRL 0.35/0.35 0.07/0.07
Low-Height 220~240 1 50 264 198
AVE-15HCFRL 0.38/0.38 0.08/0.08
Ceiling Ducted
AVE-17HCFRL 0.38/0.38 0.08/0.08
Type
AVE-19HCFRL 0.46/0.46 0.10/0.10
AVE-22HCFRL 0.57/0.57 0.12/0.12
AVE-24HCFRL 0.57/0.57 0.12/0.12

< 50 Hz >,< 60 Hz >


Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum RNC IPT
AVE-05HJFDL 0.32/0.32 0.03/0.03
AVE-07HJFDL 0.32/0.32 0.03/0.03
AVE-09HJFDL 0.43/0.43 0.05/0.05
DC Low Height AVE-12HJFDL 0.43/0.43 0.05/0.05
Ducted Type AVE-15HJFDL 220~240 1 50/60 264 198 0.50/0.50 0.06/0.06
AVE-17HJFDL 0.50/0.50 0.06/0.06
AVE-19HJFDL 0.50/0.50 0.06/0.06
AVE-22HJFDL 0.75/0.75 0.09/0.09
AVE-24HJFDL 0.75/0.75 0.09/0.09

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

73
Safety and Control Device Setting

Indoor Unit
Low-Height Ceiling Ducted Type

Indoor Unit Capacity (kBtu/h) 05~24

Temperature
Controller on Fan Cut-out
Motor of Indoor Unit Cut-in

Capacity of Fuse on Indoor


Unit Control Circuit

Freeze Protection Cut-out


Temperature Cut-in
Set Temperature
Difference

DC Low Height Ducted Type

Indoor Unit Capacity (kBtu/h) 05~24

Capacity of Fuse on Indoor


Unit Control Circuit

Freeze Protection Cut-out


Temperature Cut-in

Set Temperature
Difference

74
6.7 Electrical Wiring Diagram
Model: AVE-05~24HCFRL
Signal Receiver

PCB1
CN20 1 2 3 4 5 6 7 8 9 10
TB1

T 5A

L-1

N-1

YX4 YX3 YX2

LO ME HI
4 N

3 2 1
MD

Motor for Drain


Discharge Mechanism
Operation Line
Remote Control
Switch

Name
CA
MV1
CN
EFR1
FS
ITI
MIF
MV
PCB1
PCN2,6,18

TB1,2
Before inspecting the electrical
WARNING THM1,3,5
parts set the Operation Switch
to OFF, and cut OFF the power YH2
supply.
MD

75
Electrical Wiring Diagram

Model: AVE-05~24HJFDL

: Factory Wiring Remote Control


Switch
: Earth Wiring
: Field Wiring Operation Line
DC5V
: Optional Parts Motor for Drain
Discharge Mechanism
: Models Parts

Name
PCB1
CN
DSW, RSW
EFR1,EFS1
WARNING Before inspecting the electrical parts set the
FS Operation Switch to OFF, and cut OFF the power
MIF
MV1
supply.
PCN
TB1,2
MD Note :
THM
YH2
1.
. All the field wiring and equipme
must comply with local codes.
76
6.8 Indoor Unit Optional Parts

Optional Parts Applied Indoor Unit Type


Low-Height Ceiling DC Low Height
Type
Model Ducted Type Ducted Type
HYXE-VA01 Y Y
HYXE-J01H Y Y
HYXE-J01H1 Y Y
HYXE-J01H2 Y Y
Wire Remote Control Switch
HYXE-M01H Y Y
HYXE-S01H Y Y
HYXM-VB01 Y Y
HYXM-VB01#01 Y Y
Wireless Remote Control Switch HYE-W01 Y Y
Wireless Receiver Kit HYRE-V02H Y Y
Hi-motion HCM-S01E Y Y
HYJE-H01H Y Y
HYJM-S01H Y Y
HYJ-J01H Y Y
Centrol Station
HCCS-H128H2C1YM Y Y
HCCS-H128H2C1NM Y Y
HCCS-H247R4C1E Y Y
Connect PAC to Centrol Controller HCPC-H2M1C Y Y
HCHS-N06X Y Y
HCHS-N10X Y Y
HCHM-N04X Y Y
Water Source Switch Box
HCHM-N08X Y Y
HCHM-N12X Y Y
HCHM-N16X Y Y
HP-DB-NA Y Y
3D Air Swing
HP-EB-NA Y Y
Humidity Sensor HCHR-S01E Y Y

Note:
1.If you want to use Hi-motion in the system, the wired Controller you can choose is listed as follows: HYXM-VB01 and
HYXM-VB01#01;
2.When the Air Conditioner and window linkage function is used in the system, the sensor must be connected to the pin2 and
pin3 of CN3, so you can only use the i2 input function;

77
3.When the Air Conditioner and window linkage function is used in the system, the remote controller you can choose is limited to
the range as follow:

6.9

AVE-05~24*

Wire Clamp 2 For Power Cord and Communication Cable


Accessory Bag for Arranged around the Power Cord of Outdoor
Magnetic Ring 1 Unit

78
6.10 Install
6.10.1
Indoor Unit

Section 6.3 Selection Data

Air Filter
Screw

Fig. 6.1 Installation of Filter Screen

6.10.2.2 Maintenance and Servicing of


Filter Screen
Take down the filter screen from the machine during
maintenance, and remove the dust with dust collector or
water. To remove stubborn dirt, please dissolve neutral
detergent in cold water, and clean the screen therein.
Take out the well cleaned filter screen, dry and reinstall it.
Depending on local air quality, please clean the filter
screen every 3 months operation of air conditioner.

6.10.3 Indoor Unit Installation

6.10.3.1 Suspension Bolts

(1) Decide upon appropriate mounting position and


orientation by carefully taking into consideration the piping,
wiring and repair.
(2) Fig. 6.2 shows how to install suspension bolts.

6.10.2 Installation and Repair of Filter Screen

6.10.2.1 Installation of Filter Screen

(1) As shown in the figure below, remove the filter screen


fastening screw;
(2) Draw the filter screen down until the upper rib gets out
of the slot;
(3) Pull out the left and right ribs of filter screen out of the
machine, and take out the filter screen;
(4) Clean and reinstall the filter screen following the Fig. 6.2
reverse steps of its removal.

79
6.10.3.2 Suspension Bolt and Pipe Connection (1) How to Install Suspension Bolt and Nut
Mount nuts to the four bolts as shown in Fig. 6.5.
Points

(1) Indicate the location of suspension bolt, and the


connection points of refrigerant pipe and drain pipe.

(2) Installation dimensions are shown in Fig. 6.3.

Approx. 50mm
Nut
mm
a (Suspension Bolt Size)
375 (Suspension Bolt Size)

192mm
Washer Indoor Unit
Nut

Fig. 6.5 Suspension Bolts and Nuts

Outlet Direction

(2) Installation of Indoor Unit


* Place the left bracket on the nut and washer of
Top View
suspension bolt as shown in the figure below.
* Make sure the left bracket is properly placed on the nut
Size and washer, and put the right bracket of indoor unit on the
nut and washer.
Indoor Unit Capacity (kBtu/h)

05 12 751 695

15 17 962 906 (The suspension bolt can be slightly shifted for the
placement of indoor unit.)
19 24 1232 1176

Fig. 6.3 Suspension Bolt

Suspension Bracket
6.10.3.3 Installation of Indoor Unit Suspension Bolt
Indoor unit is installed as shown in Fig.6.4 Suspension Bracket
Installation of Field-Supplied Parts

Suspension Bolt 4-M10 or W3/8


Nut 8-M10 or W3/8
Washer 8-M10 or W3/8
Nut and Washer Indoor Unit

Suspension Bolt (4-M10 or W3/8)


(Field Supplied)
Nut and Washer
(4-M10 or W3/8)
(Field Supplied) Fig. 6.6 Handling Method

Support Leg

Fig. 6.4 Installation of Indoor Unit

80
6.10.3.4 Leveling of Indoor Unit
(1) Check to ensure the top surface is level, and 6.11. Refrigerant Piping Work
measure the max. top surface inclination degree.


Use refrigerant R410A in the refrigerant cycle. Do not charge
oxygen, acetylene or other flammable and poisonous gases into
the refrigerant cycle when performing a leakage test or an air-
tight test. These types of gases are extremely dangerous and
can cause an explosion. It is recommended that nitrogen be
used for these tests.

6.11.1 Piping Materials


(1) Prepare field-supplied copper pipes.
Fig. 6.7 Top Surface Inclination Degree
(2) Select clean copper pipes. Make sure there is no dust and
(2) As shown in Fig. 6.7, the rear part of indoor unit is slightly moisture inside. Blow the inside of the pipes with nitrogen or dry
lower than its front part (by 0~5mm) so as to facilitate air, to remove any dust or foreign materials before connecting
drainage. pipes.
(3) Tighten the suspension nut upon completion of (3) Select copper pipes based on Fig. 6.10.
adjustment. It's essential to apply thread locking agent to
avoid nut looseness.


Please cover the machine with plastic cloth during installation
so as to keep it clean.
6.10.3.5 Air Duct Connection

●Connection of Air Duct for Indoor Unit without Electric Heating

Air duct is connected to indoor unit via canvas hose to


effectively isolate noise and vibration.

<Example>

Thermal
Insulation Material Flexible Canvas Connection Flexible Canvas Connection

Air Outlet Level


Return Air Inlet
Service Access
(with Filter Screen)
(600mm×600mm)

Fig. 6.8 Air Duct Connection

81
6.11.2 Piping Connection (2) As shown in Fig. 6.12, two spanners shall be used
for tightening the nut.
(1) Piping connection points are shown in Figs. 6.9 and 6.10.

Refrigerant Refrigerant
Liquid Pipe Gas Pipe

Pipe Size (mm) Tightening Torque (N•m)

Drain Pipe (for 63


Drain Pump)

Fig. 6.9 Piping Connection Points


Fig. 6.12 Nut Tightening Torque

Indoor Unit Capacity (kBtu/h) Gas Pipe Liquid Pipe (3) Insulate the refrigeration piping with field-supplied
05~17 ※ insulating pipe upon completion of refrigerant pipe
connection. See Fig. 6.13.
19 ※
22, 24 ※ Wire Tie (Option) Insulating Pipe (Option)

Fig. 6.10 Pipe Size Refrigerant Piping Work


(Field Supplied)

※ Since the nut cap connected at gas pipe is Indoor Unit


designed exclusively for R410A, the piping flaring Side
connected for off-factory installation is adjusted as Insulating Pipe
compared with R22 and R407C. Please perform the (Field Supplied)

processing operation based on the dimensions Thermal Insulation Material (Option)


shown below: (See Fig. 6.11)
Fig. 6.13 Thermal Insulation of Pipes

90°±2° !
45°±2° Unit:
Cap the end of pipe when the pipe is to be inserted
Outside Diameter of
Piping(a) through a hole.
Do not put pipes on the ground directly without a cap or
Outside vinyl tape at the end of the pipe.
Diameter
of
Flaring (D) R410A Do not put pipes on the ground directly
a
D Correct

Fig. 6.11 Flaring

Incorrect
Blocked with tape or plug

(4) Discharging and Charging Refrigerant


Follow the Installation & Maintenance Manual for
outdoor unit.

82
! !
Excessive and inadequate refrigerant is a leading cause Where the relative humidity of air inlet or ambient air
of system anomaly. Please inject the right amount of exceeds 80%, an auxiliary drain pan shall be fabricated at
refrigerant. installation site and placed under the indoor unit, as shown
in Fig. 6.15.

6.11.3 Drain Pipe Indoor Unit


(1) See Fig. 6.14 for connection point of drain pipe.
(2) Find a PVC pipe with an outside diameter of 32mm.
(3) Fix the PVC pipe to drain pipe through adhesive and Auxiliary Drain Pan
factory-supplied clamp. The downward inclination of (Field Supplied)
drain pipe is 1/25~1/100.
(4) Make thermal insulation after the proper connection
of drain pipe. Drain Outlet
Fig. 6.15 Drain Pan
Drain Pipe (PVC Pipe, VP25)
Pipe Support (Field Supplied)
(Field Supplied)
1/25~1/100 downward inclination
90º Bend (VP25)
(Field Supplied) !
Drain Lift Pipe (PVC Pipe, VP25)
(Field Supplied) (1) The drain pipe installed shall slope down; otherwise, the
condensate may flow back and leak into the room when
374~900 (Lift)

Indoor Unit Drain Pipe (L300) the indoor unit is turned off.
(Option)

(2) The drain pipe shall not be connected with sewage pipe
or other drain pipes.
Rubber Stopper
Drain Pan
(Accessory) (3) Where the main drain is connected to other indoor units,
each indoor unit must be higher than the main. Select
Drain Pump
drain pipes in ample size depending on the refrigerating
capacity and quantity of indoor units.

Fig. 6.14 Drain Pipe (4) Check if water flows without obstruction following the
procedure shown below after the proper connection of
wires and drain pipes.

a. Turn on the power


b. Fill the drain pan with 2L or 2.5L of water.
c. Check and ensure the water flows without obstruction
and no leakage exists. Pour 2L of water if no water flows
out of pipe end.

83
6.12 Electrical Wiring 6.12.1 General Check
Make sure that the field-selected electrical components
(main power switches, circuit breakers, wires, conduit
connectors and wire terminals) have been properly
! selected according to the electrical data given in
Turn OFF the main power switch to the indoor unit and "Technical Catalog I". Make sure the components comply
the outdoor unit and wait for at least 3 minutes before with National Electrical Code (NEC).
electrical wiring work or a periodical check is performed. Check to ensure that the power supply voltage is within
Check to ensure that the indoor and outdoor fans have ±10% of the rated voltage.
stopped before electrical wiring or a periodical check. Check the capacity of the electrical wires. If the power
Protect the wires, drain pipe, electrical parts, etc. from source capacity is too low, the system cannot be started
rats or other small animals. If no protection is arranged, due to the voltage drop.
rats may gnaw at unprotected parts and at the worst, a Check to ensure that the ground wire is connected.
fire will arise.
Avoid the contact of wires with the refrigerant piping,
sheet metal edges and electrical components in unit. 6.12.2 Electrical Wiring Connection
Otherwise, the wire may be damaged or even cause fire.
Use ELB with medium sensing rate (earth leakage The electrical wiring connection for the indoor unit is shown
breaker with action time being equal to 0.1 seconds or in Fig.6.18.
less). The failure to do so may result in electric shock or Fix the wire clamp body and its nuts to the wiring hole
fire. of electric box using a torque of 1.0~1.2N.m.
The wires must be firmly secured. External force applied Connect the cable of wired control to the connectors on
to terminals may cause a fire. the printed circuit board in electric box through the wire
Never connect the power terminal block for air clamp and wiring hole.
conditioner to power cord. At the indoor unit side of air Connect power cord and the communication cables of
conditioner, power wiring can be extended through a indoor and outdoor units to corresponding terminals of
power distribution box. Be sure to calculate the wiring electric box in the same way.
capacity carefully, since excessively low wiring capacity Upon completion of electrical wiring, the wire clamp nut
may frequently cause fire. shall be manually tightened to block condensate and
Do not start the system before all check points are insects.
thoroughly checked. The external static pressure of the indoor unit is 10Pa,
while the 10Pa plug (white) of motor is connected to
base board PCBN18 terminal at delivery. To set the
external static pressure to 30Pa, please connect the
! 30Pa plug (red) of motor to the base board PCBN18
terminal. See Figs. 6.16 and 6.17.
Wrap the accessory packing around the wires, and plug White
the wiring connection hole with the seal material to
Indicating the
protect the product from any condensate or insects.
text "10Pa”
Tightly secure the wires with the cord clamp inside the
10Pa

indoor unit.
Red
Secure the cable of wired control using the cord clamp
Indicating the
inside the electric box.
text "30Pa”
Tighten screws to the following torques.
30Pa

M4: 1.0~1.3 N·m


M5: 2.0~2.4 N·m Fig. 6.16 Switching between external static pressures
M6: 4.0~5.0 N·m of 10Pa and 30Pa
M8: 9.0~11.0 N·m
M10: 18.0~23.0 N·m Enlarged view of part in Fig. 6.18

AC Motor

Fig. 6.17 Motor terminal location diagram

84
Wire Clamp

Terminal
Block (TB)

AVE-05~24HCFRL

Enlarged View of P Part

Wired
Remote
Communication Wired Control

Control
Wire
Terminal Block Commu
(TB) Wiring nication
Cable

Power
220-240V~50Hz Cord

AVE-05~24HJFDL

Wired
Remote
Communication Wired Control

Enlarged View of Control


Wire
P Part
Terminal Block Commu
(TB) Wiring nication
Cable

Power
220-240V~50/60Hz Cord

Wire Clamp Body Electric Box

Hand-Operated Nut Wire Clamp Nut


The tightening torque
is recommended to
be 1.0~1.2 N•m.
Wire

Enlarged View of R Part


(Wire Clamp Fixation Method
Diagram)

Fig. 6.18 Wiring Connection

85
6.13

6.14

Use an ELB (Electric Leakage Breaker).If not used ,it will cause an electric shock or a fire.

Run through the cables using conduit tube, and Completely seal the end of conduit tube.with sealing materials.

Power Cord Signal Wire


Indoor Unit Capacity (kBtu/h) Power Supply Max. Current
Specifications Specifications

05~07HCFRL 0.46A
09~12HCFRL 0.65A
15~17HCFRL 220-240V ~50Hz 0.70A
19HCFRL 0.85A
22~24HCFRL 1.05A
2.5mm2

05~07HJFDL 0.40A
09~12HJFDL 0.54A
15~17HJFDL 220-240V~50/ 0.63A
60Hz
19HJFDL 0.63A
22~24HJFDL 0.94A

Total Current (A) Cable for Permanent Wiring

DO NOT connect
wires in series when
the current exceeds
63A.
16

86
Note:
(1) Field wiring shall be in conformity to local laws and regulations, and all wiring operations must be performed by qualified
professionals.
(2) Refer to relevant standards for above-noted power cord size.
(3) Where power cord is connected through junction box, be sure to determine the total current and choose wires based on
the table above.
(4) As a minimum, the chosen power cord shall be compliant with requirements on neoprene sheathed wire #57 as stated
in IEC60245-1, while the power cord shall be made from copper conductor.
(5) The wiring specifications for weak-current communication circuit shall not be lower than that for RVV(S)P shielded wires
or equivalent, and the shielding layer shall be grounded.
(6) A switch that guarantees all-pole disconnection shall be installed between power supply and air conditioning unit. The
contact spacing of such switch shall not be less than 3mm.
(7) Once the power cord is damaged, the dealer or the professionals from designated maintenance department must be
contacted in a timely manner for repair and replacement.
(8) For the installation of power cord, the ground wire must be longer than the current-carrying conductor.

6.15 Setting of DIP Switch


(d) Cooling System Code No. Setting (DSW5)
AVE-05~24HCFRL
The setup is needed. All are set to OFF before delivery.
(1) DIP switch must be set with power sources of the indoor
and outdoor units in OFF state. Otherwise, the settings are
invalid.
(2) The location of DIP switch is shown in the figure below Refrigerant System Setting
DSW5 (Setting 0~63) Ex.) Set system No. 5
Setting Method 1

Note: 8421 coding method

DSW5 is set to "0" before delivery; up to 64


indoor units can be connected with.

(3) The PCB of indoor unit is furnished with 4 DIP switches Note:
that must be set based on the following requirements before
test run. The system must not be started before the Symbol "■" indicates the location of DIP switch.
completion of DIP setup. The position indicated in the diagram is in the factory-set
state.
(a) All indoor units must be numbered (DSW6) as shown
in the figure below. The outdoor unit numbering must
start with "0". !
The power supply shall be turned off before the setup of
DIP switch. Otherwise, the settings will be invalid.
Setting Method 1

DSW6 (Setting 0~63) Ex.) Set machine No. 16

Note: 8421 coding method No. 5 is ON

DSW6 is set to "0" before delivery; up to 64 indoor


units can be connected with.

(b) Capacity Code Setting (DSW3)


No setup is required.
The code is set before delivery. This switch is used to
set the capacity of indoor unit.

(c) Model Code Setting (DSW4)


No setup is required.
For the models that are not installed or set up for DSW4,
the software is set to "1&4 ON" by default.

87
AVE-05~24HJFDL
Refrigerant System Setting
DSW5 (Tens Digit) RSW2 (Units Digit) Ex.) Set system No. 5
Insert a flat head
(1) DIP switch must be set with power sources of the indoor Setting Position screw driver into the
and outdoor units in OFF state. Otherwise, the settings are slot for setup

invalid.
(2) The location of DIP switch is shown in the figure below All set to OFF
DSW5 and RSW2 are set to "0" before delivery.
When Hi-NET is used, up to 64 indoor units can be
connected.
When Hi-NET is not used, up to 16 indoor units can be
connected. Setting 5

(e) Safety Reset (DSW7)


* Factory setting.

(3) The PCB of indoor unit is furnished with 2 rotary


switches and 6 DIP switches that must be set based on the * Once strong current is accidentally
following requirements before test run. The system must not connected to Terminals 1 and 2 of
be started before the completion of DIP setup. TB2, the PCB fuse will be blown.
Then, it's necessary to correct the
(a) All indoor units must be numbered (RSW1&DSW6) wiring and then set switch No. 1 to
as shown in the figure below. The outdoor unit ON.
numbering must start with "0".

Indoor Unit Setting Note:


DSW6 (Tens Digit) RSW1 (Units Digit) Ex.) Set machine No. 16
Symbol "■" indicates the location of DIP switch.
Insert a flat head screw
The position indicated in the diagram is in the factory-set
Setting Position
driver into the slot for setup state.

No.1 is ON

DSW6 and RSW1 are set to "0" before delivery.
When Hi-NET is used, up to 64 indoor units can be
The power supply shall be turned off before the setup of
connected.
When Hi-NET is not used, up to 16 indoor units can be DIP switch. Otherwise, the settings will be invalid.
connected. Setting 6

6.16 Setting of External Static Pressure


(b) Capacity Code Setting (DSW3) Performing external static pressure setup ("C5") on wired
No setup is required. remote control can change the static pressure. Please refer
The code is set before delivery. This switch is used to to the Installation & Maintenance Manual for wired remote
set the capacity of indoor unit. control.
(c) Model Code Setting (DSW4)
No setup is required. The code is set before delivery. Indoor Unit External Static Wired Remote Control
Capacity (kBtu/h) Pressure Setting
(d) Cooling System Code No. Setting (RSW2&DSW5)
The setup is needed. All are set to OFF before delivery. 0Pa 02

05~24HJFDL 10Pa 00 (Factory


Setting)

30Pa 01

88
7. 4-Way Cassette Type
7.1 General Data
Indoor Unit Type 4-Way Cassette Type
Model AC 1 220-240V
AVBC-09HJFKA AVBC-12HJFKA AVBC-15HJFKA AVBC-19HJFKA
Power Supply ~50Hz/60Hz
Nominal Cooling kW 2.8 3.6 4.5 5.6
Capacity *1) kcal/h 2,400 3,100 3,900 4,800
Btu/h 9,600 12,300 15,400 19,100
Nominal Cooling kW 2.9 3.8 4.6 5.8
Capacity *2) kcal/h 2,500 3,300 4,000 5,000
Btu/h 9,900 13,000 15,700 19,800

Cooling Power Consumption kW 0.02 0.03 0.03 0.04


Nominal Heating kW 3.2 4.0 5.0 6.3
Capacity kcal/h 2,800 3,400 4,300 5,400
Btu/h 10,900 13,700 17,100 21,500

Heating Power Consumption kW 0.02 0.03 0.03 0.04


Sound Pressure Level
(Overall A Scale) dB 26/26/27/28/28/30 26/27/28/29/29/32 26/27/29/29/31/33 26/28/28/30/31/34
Outer Dimensions
Height mm 238 238 238 238

Width
mm 840 840 840 840

Depth
mm 840 840 840 840

Net Weight
kg 20 20 21 21

Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)


Indoor Fan
Air Flow Rate 528/600/648/720 546/648/708/768 672/762/816/894 750/816/930/954
m3/h
(Slo/Lo/Me/Hi/HH1/HH2) /804/900 /840/1020 /960/1260 /1050/1320

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
(in.) (1/4) (1/4) (1/4) (1/4)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7
(in.) (1/2) (1/2) (1/2) (1/2)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.27 0.27 0.27 0.27
Adaptable Panel Model — HP-G-NK
Color — Neutral White
Outer Dimensions
Height mm 47 47 47 47

Width mm 950 950 950 950

Depth mm 950 950 950 950

Net Weight kg 5.7 5.7 5.7 5.7

Approximate
Packing Measurement m3 0.11 0.11 0.11 0.11
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

89
Indoor Unit Type 4-Way Cassette Type
Model AC 1 220-240V AVBC-27HJFKA AVBC-30HJFKA
AVBC-22HJFKA AVBC-24HJFKA
Power Supply ~50Hz/60Hz
Nominal Cooling kW 6.3 7.1 8.0 9.0
Capacity *1) kcal/h 5,400 6,100 6,900 7,700
Btu/h 21,500 24,200 27,300 30,700
Nominal Cooling kW 6.5 7.3 8.3 9.3
Capacity *2) kcal/h 5,600 6,300 7,100 8,000
Btu/h 22,200 24,900 28,300 31,700

Cooling Power Consumption kW 0.06 0.07 0.06 0.06


Nominal Heating kW 7.1 8.0 9.0 10.0
Capacity kcal/h 6,100 6,900 7,700 8,600
Btu/h 24,200 27,300 30,700 34,100

Heating Power Consumption kW 0.06 0.07 0.06 0.06


Sound Pressure Level
(Overall A Scale) dB 28/29/31/32/33/36 28/29/31/32/33/36 30/31/33/35/36/37 30/31/33/35/36/37
Outer Dimensions
Height mm 238 238 288 288
(in.)
Width mm
840 840 840 840
(in.)
Depth mm
840 840 840 840
(in.)
Net Weight kg
23 23 26 26
(lbs.)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate 780/906/1020/1098 882/978/1080/1146 924/1008/1122/1218 966/1062/1176/1242
m3/h /1200/1560
(Slo/Lo/Me/Hi/HH1/HH2) /1260/1620 /1320/1620 /1380/1620

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ6.35 Φ9.53 Φ9.53 Φ9.53
(in.) (1/4) (3/8) (3/8) (3/8)
Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88
(in.) (1/2) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.27 0.27 0.31 0.31
Adaptable Panel Model — HP-G-NK
Color — Neutral White
Outer Dimensions
Height mm 47 47 47 47

Width mm 950 950 950 950

Depth mm 950 950 950 950

Net Weight kg 5.7 5.7 5.7 5.7


Approximate
Packing Measurement m3 0.11 0.11 0.11 0.11
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

90
Indoor Unit Type 4-Way Cassette Type
Model AC 1 220-240V AVBC-38HJFKA AVBC-48HJFKA AVBC-54HJFKA
Power Supply ~50Hz/60Hz
Nominal Cooling kW 11.2 14.0 16.0
Capacity *1) kcal/h 9,600 12,000 13,800
Btu/h 38,200 47,800 54,600
Nominal Cooling kW 11.6 14.3 16.5
Capacity *2) kcal/h 10,000 12,300 14,200
Btu/h 39,600 48,800 56,300

Cooling Power Consumption kW 0.13 0.13 0.13


Nominal Heating kW 12.5 16.0 18.0
Capacity kcal/h 10,800 13,800 15,500
Btu/h 42,700 54,600 61,400

Heating Power Consumption kW 0.13 0.13 0.13


Sound Pressure Level
(Overall A Scale) dB 33/34/36/38/40/42 34/36/38/40/44/46 36/38/40/41/44/46
Outer Dimensions
Height mm 288 288 288

Width mm
840 840 840

Depth mm
840 840 840

Net Weight kg
26 26 26

Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)


Indoor Fan
Air Flow Rate 1176/1344/1488/1644 1344/1452/1632/1776 1428/1536/1734/1842
m3/h
(Slo/Lo/Me/Hi/HH1/HH2) /1800/2220 /2010/2220 /2040/2220

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53
(in.) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88
(in.) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25
Approximate
Packing Measurement m3 0.31 0.31 0.31
Adaptable Panel Model — HP-G-NK
Color — Neutral White
Outer Dimensions
Height mm 47 47 47

Width mm 950 950 950

Depth mm 950 950 950

Net Weight kg 5.7 5.7 5.7


Approximate
Packing Measurement m3 0.11 0.11 0.11
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

91
7.2 Dimensional Data

Models: AVBC-09~54HJFKA

Unit:mm

(Opening Hole for Ceiling)


860~910
840 4-12 x 32 Holes Wired Remote Control Switch
760 (for Suspension Bolt)
Field-Supplied
(for Suspension Bolt)

(Opening Hole for Ceiling)


(for Suspension Bolt)

860~910
760

840

Shielded Twist-Pair Cable


(Min. 0.75mm2, Field-Supplied)
Air Inlet
(4) Air Outlet
(4)

(Gas Pipe and Liquid Pipe) (Drain Pipe) Suspension Bolts M10 or W3/8
(Field-Supplied)

Refrigerant Liquid Pipe Connection


(With Φ b Flare Nut)
Refrigerant Gas Pipe Connection
Drain Pipe Connection
(With Φ a Flare Nut)
110
167 (Liquid Pipe)

30
194 (Drain Pipe)

150 (Gas Pipe)

Suspended
Ceiling Affirm the distance between the
bottom of indoor unit and surface
of the suspended ceiling

Model G H I Ceiling

AVBC-09HJFKA 12.7 6.35 260


AVBC-12HJFKA 12.7 6.35 260
AVBC-15HJFKA 12.7 6.35 260
AVBC-19HJFKA 12.7 6.35 260
22

Suspended Ceiling
AVBC-22HJFKA 12.7 6.35 260
Surface of Flange
AVBC-24HJFKA 15.88 9.53 260
Indoor Unit

AVBC-27HJFKA 15.88 9.53 310


AVBC-30HJFKA 15.88 9.53 310
AVBC-38HJFKA 15.88 9.53 310
AVBC-48HJFKA 15.88 9.53 310
AVBC-54HJFKA 15.88 9.53 310

92
7.3 Selection Data

7.3.1 Sensible Heat Factor (SHF)

SHF
Indoor Unit Model
HH2 HH1 HI ME LO SLO
AVBC-09HJFKA 0.80 0.77 0.75 0.73 0.70 0.68
AVBC-12HJFKA 0.78 0.76 0.74 0.73 0.72 0.69
0.77 0.75 0.73 0.70 0.69 0.67
AVBC-15HJFKA
AVBC-19HJFKA 0.78 0.76 0.75 0.69 0.67 0.65
AVBC-22HJFKA 0.74 0.72 0.70 0.67 0.65 0.63
AVBC-24HJFKA 0.73 0.71 0.69 0.67 0.65 0.63
AVBC-27HJFKA 0.79 0.76 0.72 0.69 0.67 0.65
AVBC-30HJFKA 0.79 0.76 0.72 0.68 0.66 0.64
AVBC-38HJFKA 0.78 0.75 0.72 0.67 0.65 0.61
AVBC-48HJFKA 0.74 0.70 0.68 0.65 0.63 0.60
AVBC-54HJFKA 0.73 0.69 0.67 0.63 0.61 0.60

93
7.3.2 Sound Data
Noise Criteria Curve
Measurement Point: 1.5 Meters Beneath the Unit Power Supply: 220-240V~50Hz/60Hz

AVBC-09HJFKA AVBC-12HJFKA
90 90

Octave Sound Pressure Level(dB: Overall C Scale)


Octave Sound Pressure Level(dB: Overall C Scale)

80 80

70 70
NC-70 NC-70

NC-65 NC-65
60 60
NC-60 NC-60
HH2 HH2 NC-55
NC-55
50 HH1 50 HH1
NC-50 Hi NC-50
Hi
NC-45 NC-45
40 Me 40 Me
NC-40 Lo NC-40
Lo
NC-35 NC-35
30 SLo 30 SLo
NC-30 NC-30

20 NC-25 20 NC-25
NC-20 NC-20
10 NC-15 10 NC-15
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

AVBC-15HJFKA AVBC-19HJFKA
90 90
Octave Sound Pressure Level(dB: Overall C Scale)

80 80
Octave Sound Pressure Level(dB: Overall C Scale)

70 70
NC-70 NC-70
NC-65 NC-65
60 60
HH2 NC-60 NC-60
HH1 HH2
Hi NC-55 NC-55
50 50 HH1
Me NC-50 Hi NC-50
Lo NC-45
40 NC-45
40 Me
SLo NC-40
Lo NC-40
NC-35 SLo
30 NC-35
NC-30 30
NC-30
20 NC-25
20 NC-25
NC-20
NC-20
10 NC-15
63 125 250 500 1k 2k 4k 8k 10 NC-15
63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

94
Sound Data
Noise Criteria Curve
Measurement Point: 1.5 Meters Beneath the Unit Power Supply: 220-240V~50Hz/60Hz

AVBC-22HJFKA AVBC-24HJFKA
90 90
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


80 80

70 70
NC-70 NC-70

NC-65 NC-65
60 60
NC-60 NC-60
HH2 HH2 HH1
HH1 NC-55 NC-55
50
50 Hi Hi NC-50
NC-50
Me
Me NC-45
NC-45 40
40 Lo Lo NC-40
SLo NC-40 SLo
NC-35
NC-35 30
30 NC-30
NC-30
20 NC-25
20 NC-25
NC-20
NC-20
10 NC-15
10 NC-15 63 125 250 500 1k 2k 4k 8k
63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

AVBC-27HJFKA AVBC-30HJFKA
90 90
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

80 80

70 70
NC-70 NC-70
NC-65 NC-65
60 HH2 60 HH2
NC-60 HH1 NC-60
HH1 Hi
Hi NC-55 NC-55
50 50 Me
Me NC-50 Lo NC-50
NC-45 NC-45
40 Lo 40 SLo
SLo NC-40 NC-40
NC-35 NC-35
30 30
NC-30 NC-30

20 NC-25 20 NC-25
NC-20 NC-20
10 NC-15 10 NC-15
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

95
Sound Data
Noise Criteria Curve
Measurement Point: 1.5 Meters Beneath the Unit Power Supply: 220-240V~50Hz/60Hz

AVBC-38HJFKA AVBC-48HJFKA
90 90
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


80 80

70 70
NC-70 HH2 NC-70
HH2 HH1
HH1 NC-65 NC-65
60 60 Hi
Hi NC-60 NC-60
Me NC-55 Me NC-55
50 Lo 50 Lo
SLo NC-50 NC-50
SLo
NC-45 NC-45
40 40
NC-40 NC-40
NC-35 NC-35
30 30
NC-30 NC-30

20 NC-25 20 NC-25
NC-20 NC-20
10 NC-15 10 NC-15
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

AVBC-54HJFKA
90
Octave Sound Pressure Level(dB: Overall C Scale)

80

70
HH2 NC-70
HH1 NC-65
60 Hi
Me NC-60
Lo NC-55
50 SLo
NC-50
NC-45
40
NC-40
NC-35
30
NC-30

20 NC-25
NC-20
10 NC-15
63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second)

96
AVBC-09HJFKA,AVBC-12HJFKA
Cooling Heating
Discharge angle: 45° Discharge angle: 45°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.5 1.5 1.5 1.5

0.6 0.6 2m 0.6 0.6 2m

0.4 0.4 0.4 0.4

1m 1m
0.2 0.2 0.2 0.2

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
14 14 36 36

2m 2m
17 17
23 23
29 29
1m 27 27 1m
18 18 24
20 24
20 28 28

19 19 27 27
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

AVBC-15HJFKA
Cooling Heating
Discharge angle: 45° Discharge angle: 45°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.6 1.6 1.6 1.6

0.7 0.7 2m 0.7 0.7 2m

0.4 0.4 0.4 0.4

1m 1m
0.2 0.2 0.2 0.2

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
14 14 36 36

2m 2m
16 16
23 23
29 29
1m 28 28 1m
18 18 24
20 24
20 28 28

19 19 27 27
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

97
AVBC-19HJFKA,AVBC-22HJFKA
Cooling Heating
Discharge angle: 45° Discharge angle: 45°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.8 1.8 1.8 1.8

2m 2m
0.7 0.7 0.7 0.7

0.4 0.4 0.4 0.4


1m 1m

0.2 0.2 0.2 0.2


0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
14 14 36 36

2m 2m

20 17 17 24 24
20 30 30

1m 28 28 1m
18 18

29 29
19 19 28 28
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

AVBC-24HJFKA

Cooling Heating
Discharge angle: 45° Discharge angle: 45°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.0 2.0 2.0 2.0

2m 2m
0.6 0.6 0.6 0.6

0.4 0.4 1m 0.4 0.4 1m

0.2 0.2 0.2 0.2 0.2 0.2


0.2 0.2
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
14 14 36 36

19 19 2m 2m
26 26
17 17 20 24
20 24 30 30
1m 1m
18 18 28 28
29 29
18 18
28 28
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

98
AVBC-27HJFKA
Cooling Heating
Discharge angle: 45° Discharge angle: 45°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.3 2.3 2.3 2.3

2m 2m

0.8 0.8 0.8 0.8

1m 1m
0.4 0.4 0.4 0.4

0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2


0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
14 14 36 36
18
2m 2m
25 25

17 17

1m 1m
19 18 18 19 30 30
29 29
28 28
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

AVBC-30HJFKA,AVBC-38HJFKA
Cooling Heating
Discharge angle: 45° Discharge angle: 45°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.5 2.5 2.5 2.5

1.0 1.0 2m 1.0 1.0 2m

0.6 0.6 0.6 0.6


1m 1m

0.4 0.4 0.4 0.4


0.2 0.2 0.2 0.2
0.2 0.2 0.2 0.2
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
14 14 36 36
18
16 16 2m
2m 25 25
19 19

18 17 17 18 1m 29 29 1m

30 30
28
28
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

99
AVBC-48HJFKA,AVBC-54HJFKA
Cooling Heating
Discharge angle: 45° Discharge angle: 45°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
3.0 3.0 3.0 3.0

2m 2m
1.0 1.0 1.0 1.0

0.6 0.6 1m 0.6 0.6 1m

0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3


0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
14 14 36 36

19 2m 27 27 2m
19 18 16 18
16 32 32

17 1m 30 30 1m
17
17 17 31 31
30 30
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

100
7.3.3 Component Data

Indoor Heat Exchanger and Fan

Model AVBC--09* AVBC--12U* AVBC--15* AVBC--19*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 5.0 5.0 5.0 5.0
Rows - 2 2 2 2
Fin Material Aluminum
Pitch mm 1.3 1.3 1.3 1.3
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.29 0.29 0.41 0.41
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1 1
Outer Diameter mm 490 490 490 490
Revolution (220V-240V) rpm 398/350/328 443/394/351 477/394/368 481/395/370
/305/281/257 /327/297/267 /341/315/288 /344/318/292
Nominal Air Flow m3/h 900/804/720 1020/840/768 1260/960/894 1320/1050/954
/648/600/528 /708/648/546 /816/762/672 /930/816/750
Indoor Fan Motor Drip-Proof Type Enclosure
-
Starting Method DC Driven
Nominal Output W 57 57 57 57
Quantity - 1 1 1 1
Insulation Class - E E E E

Model AVBC--22* AVBC--24* AVBC--27* AVBC--30*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 5.0 5.0 5.0 5.0
Rows - 3 3 3 3
Fin Material Aluminum
Pitch mm 1.3 1.3 1.3 1.3
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.41 0.41 0.53 0.53
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1 1
Outer Diameter mm 490 490 490 490
Revolution (220V-240V) rpm 593/471/438 608/491/459 575/491/458 575/511/472
/405/372/339 426/396/366 /425/392/359 /433/403/373
Nominal Air Flow 1560/1200/1146 1620/1260/1146 1620/1320/1218 1620/1380/1242
m3/h
/1080/978/882 /1080/978/882 /1122/1008/924 /1176/1062/966
Indoor Fan Motor Drip-Proof Type Enclosure
-
Starting Method DC Driven
Nominal Output W 57 57 57 57
Quantity - 1 1 1 1
Insulation Class - E E E E

101
Indoor Heat Exchanger and Fan

Model AVBC--38* AVBC--48* AVBC--54*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 5.0 5.0 5.0
Rows - 3 3 3
Fin Material Aluminum
Pitch mm 1.3 1.3 1.3
Maximum Operating Pressure MPa 4.15 4.15 4.15
Total Face Area m2 0.53 0.53 0.53
Number of Coil/Unit - 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1
Outer Diameter mm 490 490 490
Revolution (220V-240V) rpm 774/651/603 774/711/645 774/732/667
/555/499/443 /579/533/487 /601/564/527
Nominal Air Flow m3/h 2220/1800/1644 2220/2010/1776 2220/2040/1842
/1488/1344/1176 /1632/1452/1344 /1734/1536/1428
Indoor Fan Motor Drip-Proof Type Enclosure
-
Starting Method DC Driven
Nominal Output W 127 127 127
Quantity - 1 1 1
Insulation Class - E E E

102
7.3.4 Electrical Data

Indoor Unit

Unit Main Power Applicable Voltage Indoor Fan Motor


Model
RNC IPT
VOL PH Hz Maximum Minimum
Cooling/Heating Cooling/Heating
AVBC-09HJFKA 0.17/0.17 0.014/0.014
AVBC-12HJFKA 0.27/0.27 0.024/0.024
AVBC-15HJFKA 0.37/0.37 0.024/0.024
4-Way AVBC-19HJFKA 0.37/0.37 0.034/0.034
Cassette AVBC-22HJFKA 0.57/0.57 0.054/0.054
220-240 1 50/60 264 198
Type AVBC-24HJFKA 0.67/0.67 0.064/0.064
AVBC-27HJFKA 0.57/0.57 0.054/0.054
AVBC-30HJFKA 0.57/0.57 0.054/0.054
AVBC-38HJFKA 1.17/1.07 0.124/0.124
AVBC-48HJFKA 1.17/1.07 0.124/0.124
AVBC-54HJFKA 1.17/1.07 0.124/0.124

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

7.3.5 Safety and Control Device Setting

Indoor Unit

Model AVBC-09~54HJFKA

For Control Circuit


A 5
Fuse Capacity
Freeze Protection
Thermostat
Cut-Out ℃ 0
Cut-In ℃ 14
Thermostat
℃ 2
Differential

103
7.4 Electrical Wiring Diagram
Model: AVBC-09~54HJFKA

220-240V ~50/60Hz

104
7.5 Indoor Unit Optional Parts
Optional Parts Applied Indoor Unit Type

Type Model 4-Way Cassette Type

HYXE-VA01 ●

HYXM-VB01 HYXM-VB01#01 ●

Wire Remote Control Switch HYXE-J01H HYXE-J01H1 ●

HYXE-M01H ●

HYXE-J01H2 ●

Wireless Remote Control Switch HYE-W01 ●

Fresh Air Inlet HFL-56CSA ●

Wireless Receiver Kit HYRE-T03H ●

Motion Sensor HCM-01E ●

7 Day Timer HYDE-E01H ●

Humidity sensor HCHR-S01H ●

HYJE-D02H ●

HYJM-S01H ●

Centrol Station HYJ-J01H ●

HCCS-H128H2C1YM ●

HCCS-H128H2C1NM ●

Anion Generator HJK-ELZA ●

Interface for Building Control HCPC-H2M1C ●

HPS-162#E

Drain Pump HPS-132#E

HPS-151#E

HF-224L-FE

Long Life filter HF-280L-FE

HF-40L-ZFE

HP-DB-NK
3D Air Swing
HP-EB-NK

● means optional.

105
7.6

Panel (optional): HP-G-NK

106
7.7 Installtion
7.7.1 ● The figure on the right shows the sensing area of
motion detector when the motion detector in
panel is in service.
below.
Mounting height h of indoor unit (m) Approx.2.7m Approx.3.0m Approx.4.2m

Sensing area Φa of motion detector (m) Approx. 5.4m Approx.6.3m Approx.8.0m


Sensing area Φb of motion detector (m) Approx. 3.0m Approx.3.4m Approx.4.3m

Motion detector

Piping Connection Piping Connection Piping Connection 0.8m above the ground
Service Access Service Access Service Access
Door ≥ 450 Door ≥ 450 Door ≥ 450 Motion detector

Distance from Wall Side

Piping Connection

Service Space b
0.8m above the ground

͓ The indoor unit must be installed at an appropriate


location so that the indoor temperature can be evenly
distributed.
͓ There should be no obstruction of air flow at the vent.
͓ Do not install the indoor unit in a machinery shop
or kitchen where vapor from oil or its mist flows
to the indoor unit.
Once the oil deposits on the heat exchanger, it
may impair the performance of indoor unit and
10~20 mm
cause damage to plastic parts therein.
260 mm (09-24) ͓ Pay attention to the following points when the
310 mm (27-54) indoor unit is installed in a hospital or other
facilities where there are electronic waves from
medical equipment, etc.
Indoor Unit Height in Ceiling
(A) Do not install the indoor unit where the
electromagnetic wave is directly radiated to the
Drain Pipe electrical box, remote control cable or remote
control.
1/25~1/100 Down Slope (B) Install the indoor unit and components as far as
practical or at least 3 meters from the
electromagnetic wave radiator.
(C) Install the remote control switch in an iron box.
Arrange the remote control cable in an iron
tube. Ground the iron box and iron tube.
(D) Install a noise filter when the power supply emits
harmful noises.
͓ To avoid any corrosive action to the heat
exchangers, do not install the indoor unit in
an acid or alkaline environment.

107
7.7.2 Installation 7.7.2.2
7.7.2.1 Opening of False Ceiling and Suspension Bolts
Liquid Pipe
(1) Select appropriate location and direction for installation
of indoor unit, and determine its location. Pay careful (Use the Φb nut cap)
Gas Pipe
attention to the space for the piping, wiring and Drain Pipe
maintenance. (Use the Φa nut cap)

(2) Cut out the area for the indoor unit in the false
ceiling and install suspension bolts, as shown in Fig. below.

167 (Liquid Pipe)


194 (Drain Pipe)

110
860~910 (Dimension of Opening )

150 (Gas Pipe )

30
840(Dimension of Indoor Unit)
Suspension Bolts Surface of Ceiling
760 Suspension Bolts
(Dimension of Suspension Bolts) Confirm the distance between the bottom surface
of indoor unit andt he surface of ceiling.
(Dimension of Suspension Bolts)

840 (Dimension of Indoor Unit)

(Dimension of Opening )
860-910
760

Cooling Pipe Drain Pipe


4 location of Suspension Bolts
(M10 or W3/8)
Fig. Mounting Suspension Bracket

Fig. Opening of False Ceiling and Suspension Bolts

(3) Ensure that the ceiling is horizontally level;


otherwise, proper drainage flow would be impossible.
(4 ) Strengthen the opening parts of the ceiling. 7.7.3 Mounting the Indoor Unit
(5) Mount suspension bolts, as shown in the figure.
(1) Mount nuts and washers to the suspension bolts.
For Concrete Slab For Steel Beam
150 to 160mm Screw in Suspension Bolt (Field Supplied) Approx. 50
mm
(100 to 150kg) Nut (Field Supplied)
Concrete * Insulating Washer
(Accessory)
Suspension Bolt Bracket (for Fixing Indoor Unit)
Fixing Point , Beam Washer (Accessory)
(W3/8 or M10)
Nut (Field Supplied)
Suspension Bolt
Approx. 50
110

(W3/8 or M10) Surface of Ceiling


For Wooden Beam * Mount the washer with its insulating surface
Suspension facing down
Wooden Rib
(60mm to 90mm Fig. Mounting Nuts and Washers
lumber) Nut
Square Washer

(2) Lift the indoor unit by hoist, and do not


Square Washer put any force on the water pan.
Nut
Wooden Beam Suspension Bolt

Fig. Mounting the Suspension Bolts

108
(2) Adjust the indoor unit to the correct position
using the factory-supplied inspection ruler

10~35
Ceiling

10~35 10~35 Indoor Unit

22
Surface of

10~35
Flange Surface Indoor Unit Suspended
(Bottom View) Ceiling

(a) For suspended ceiling with panel installed

Put the inspection ruler Put the inspection ruler at


below the indoor unit surface of suspended ceiling

7.7.4 Opening size of inspection ruler

Check the heights of suspended ceiling and


indoor unit at each corner
Check the size of each side

(b) For ceiling without panel

e Op
Siz eni
g ng
nin Siz
O pe e

Pattern Board for Installation

Suspension Bolt

Indoor Unit
(1) The pattern board for installation is in the
packing carton. Please cut it off.
Bolt (M6)
Surface of Ceiling
Inspection Ruler
Pattern Board for Installation

Installation Details for Air Panel

Package (Corrugated Board) Pattern Board for Installation ͓ The details of installation work for air panel
shall be according to the Installation Manual.
͓ Check to ensure the proper connection of
connectors between the indoor unit and air
Fig. Mounting Indoor Unit
panel.

109
7.8. Refrigeration Piping

'$1*(5 (2) As shown in Fig. two spanners shall be used for


tightening the nut
Use refrigerant R410A in the refrigerant cycle. Do not
charge oxygen, acetylene or other flammable and
poisonous gases into the refrigerant cycle when
performing a leakage test or an air-tight test. These
gases are extremely dangerous and can cause an
explosion. It is recommended nitrogen be used for
those tests.
7.8.1 Piping Materials Pipe Size Tightening Torque (N.m)
(1) Prepare locally-supplied copper pipes. Φ6.35 20
Φ9.53 40
(2) Select copper pipes based on Fig. below.
Φ12.7 60
(3) Select clean copper pipes. Make sure there is Φ15.88 80
nodust and moisture inside. Blow the inside of Φ19.05 100
the pipes with nitrogen or dry air, to remove any
dust or foreign matters before connecting pipes. Fig. Nut tightening torque
Unit: mm (in.) (3) Insulate the refrigeration piping with field-
supplied insulating pipe upon completion of
Capacity of indoor unit(10 3 BTU) Gas Pipe Liquid Pipe
refrigerant pipe connection. See Fig.
09~22 Φ12.7(1/2) Φ6.35(1/4)
Cord Clamp Insulating Pipe
24~54 Φ15.88(5/8) Φ9.53(3/8) (Field-Supplied)
(Factory-Supplied)
Refrigeration Piping

7.8.2 Piping Connection (Field-Supplied)

(1) The connection point and diameter of piping Unit Side

are shown in Figs below.


Insulating Pipe
840 (dimensions of indoor unit) (Field-Supplied)
Insulating Pipe

Connected to Liquid Pipe


160 (Liquid Pipe)

95 (Gas Pipe)
Fig. Insulation on Pipes

● Cap the end of the pipe when the pipe is to


150 (Connected to
167 (Connected to

Connected to Gas Pipe


penetrate a hole.
Liquid Pipe)

Gas Pipe)

● Do not put pipes on the ground directly without a


cap or vinyl tape arranged at the end of the pipe.

Do not put pipes on the ground directly


Correct
Fig. Pipe Connection Points

Since the nut cap connected at gas pipe is


designed exclusively for R410A, the piping flaring
connected for off-factory installation is adjusted as Incorrect
compared with R22 and R407C. Please perform Blocked with Tape or Plug
the processing operation based on the dimensions
shown below: (See Fig. )
(4) Discharging and Charging Refrigerant
90 0 ±2 0 Follow the Installation & Maintenance Manual for
Unit: mm (in.)
45 0 outdoor unit.
±2 0
Outside Diameter of Φ12.7 Φ15.88
Piping (a) (1/2) (5/8)
Outside
R

R22、R407C 16.2 19.4


0.

Diameter
4~
0.

of Flaring
8

(D) R410A 16.6 19.7

a
D 0 -0.4 Fig. Flaring
110
7.9 below.

Connected to Drain Pipe

The drain pipe installed shall slope down; otherwise,


the condensate may flow back and leak into the room

194
units, each indoor unit must be higher than the main.
Select drain pipes in ample size depending on the
refrigerating capacity and quantity of indoor units.
when the indoor unit is turned off.

The drain pipe shall not be connected with sewage


pipe or other drain pipes.

Where the main drain is connected to other indoor

Check if water flows without obstruction following the


procedure shown below after the proper connection of
wires and drain pipes.

A.Turn on the power. (Fastening torque is 3.0-3.5N m)


(Accessory)

B.Fill the water pan with 2L or 2.5L of water.


C.Check and ensure the water flows without
obstruction and no leakage exists. Pour 2L
of water if no water flows out of pipe end.

● Inject water via access opening.

Insert the end of hose between


heat exchanger and water pan.

Access Opening

Water Pump

Water (2L or 2.5L)

● Inject water via air outlet.

Insert the end of hose between


heat exchanger and water pan.

Water Pan
Water Pump

Water (2L or 2.5L)

111
7.10.1 General Check

Where the relative humidity of air inlet or (1) Make sure that the field-selected electrical
ambient air exceeds 80%, an auxiliary water pan components (main power switches, circuit
breakers, wires, conduit connectors and wire
shall be fabricated at installation site and placed terminals) comply with the National Electrical
under the indoor unit, as shown in Fig. below. Code.
(2) Check to ensure that the power supply voltage is
within ±10% of the rated voltage. The system
Indoor Unit can’t be started in the case of excessively low
supply voltage.
(3) Check the power capacity.
Condensate Pan

Field-Supplied (4) Ensure the ground wire is connected.

7.10.2 ElectricalWiring Connection


Water Outlet
Fig. Auxiliary Water Pan The electrical wiring connection for indoor unit is
shown in Fig. below.
7.10 Electrical Wiring (1) Connect transmission wiring to the PBC
in electrical box through the connection hole
on electrical box.
:$51,1* (2) Connect the power wiring and earth wires to
͓ Turn OFF the main power switches to the indoor the terminals in the electrical box.
unit and outdoor unit before electrical wiring or (3) Connect the wires between the indoor unit
periodical check, and wait for at least three and the outdoor unit to the terminals in
minutes. electrical box.

Wire Tie Piping bezel


͓ Check to ensure the indoor and outdoor fans
have stopped before electrical wiring or periodical line plate
Wiring interface
check.
Screw
Electrical Box

͓ Protect the wires, drain pipes, electrical parts,


etc. from rats or other small animals. If not PCBA
protected, rats may gnaw at unprotected parts,
which may lead to a fire.

Electrical Box Cover

Screw
(Electrical Box Cover)

PCB
͓ Wrap the wires with adhesive tape or other materials (Indoor and outdoor ● Indoor) Earth Wiring Screw
and plug the wiring connection hole with seal
material to protect the product from any
condensate water or insects.
Screw
͓ The electrical box entrance hole shall be
designed with wire clamp that must be tightened Fixed clamp
to address tension requirements when penetrated Electrical Box
by wires. line plate
͓ Secure the remote controller wire in electrical box B
with wire tie.
͓ Tighten screws to the following torques. Remote Controller Indoor and Outdoor
Wiring connection Wiring

112
Terminal Row(black)

Terminal Row(black)
light current ● Wiring is connected to the terminal row, be
sure to use wire tie binding, wiring must be
placed in the chute, to prevent the
squeeze, a fire.
Electrical Box
A larger Image

Power cord fastening


method:
1. Clamp the power cord
through the solid thread, as
shown in the figure on the
right.
2. The fixing clamp is
mounted on the piping plate
and the screw is scrim.

B larger Image

Fig. Electrical Wiring Connection for Indoor Unit

To provide the minimum size of the power cord in the field, please follow the relevant national laws.

Maximum Power Cord Size Communication Wire


Capacity of indoor unit(103BTU) power source
Current Size

1.0A
09~30
220V-240V~
2.5mm2 0.75mm2
50/60Hz

38~54 1.8A

Totle Current(A) Power Cord(mm2)

I≤6 2.5 ※1
In the case that
6<I≤10 2.5
current exceeds
10<I≤16 2.5 63A, do not
16<I≤25 4 connect cables in
25<I≤32 6 series.
32<I≤40 10
40<I≤63 16
63<I ※1

113
Note:
(1) Field wiring shall be in conformity to local laws and regulations, and all wiring operations
must be performed by qualified professionals.
(2) Refer to relevant standards for above-noted power cord size.
(3) Where power cord is connected through junction box in series, be sure to determine the
total current and choose wires based on the table above.
(4) As a minimum, the chosen power cord shall be compliant with requirements on
neoprene sheathed wire #57 as stated in IEC60245-1, while the power cord shall be made
from copper conductor.
(5) The wiring specifications for weak-current communication circuit shall not be lower than
that for RVV(S)P shielded wires or equivalent, and the shielding layer shall be
grounded.
(6) A switch that can ensure all-pole disconnection shall be installed between power supply
and air conditioning unit in such a manner that the contact spacing shall not be less than
3mm.
(7) Once the power cord is damaged, the dealer or the professionals from designated
maintenance department must be contacted in a timely manner for repair and
replacement.
(8) For the installation of power cord, the ground wire must be longer than the current-
carrying conductor.

7.11 Test Run


Test run should be performed according to the
Installation & Maintenance Manual.

:$51,1*
͓ Do no operate the system until all the check points ͓ Pay attention to the following items while the system
are cleared. is running.
(A) Check to ensure the electrical resistance between (A) Do not touch any of the parts by hand at the
terminal and ground is more than 1 MΩ. If this is discharge gas side, since the temperatures of
not the case, do not operate the system until the compressor chamber and the pipes at the
electrical leakage is found and repaired. discharge side are higher than 90°C.
(B) Check to ensure the stop valves of outdoor unit are (B) DO NOT PUSH THE BUTTON OF THE AC
fully opened, and then start the system. CONTACTOR. It will cause a serious
(C) Check to ensure the switch on main power source accident.
has been ON for more than 4 hours to
warm the compressor by heater.

114
7.12 Common
7.12.1 Field Operation
7.12.1.1 Setting of Dip Switches (c) Safety reset (DSW7)
(1) DIP switch must be set with power sources of the  Factory settings
indoor and outdoor units in OFF state. Otherwise,
the settings are invalid.
Once strong current is
(2) The DIP switches are located as shown in the
accidentally connected to
figure below. Terminals 1 and 2 of TB2, the
PCB fuse will be blown. In such
a case, it's essential to correct
the wiring and then to set switch
No. 1 to ON position.
(Refrigerant System Settings)

Note:
(Communications
short fuse)
Symbol " " indicates the location of DIP switch.
The position indicated in the diagram is in the
factory-set state.

CAUTION
(Address Settings) (Volume Settings)
(Option Settings)
(Machine Settings)
The power supply shall be turned off before the
setup of DIP switch. Otherwise, the settings will be
(3) 6 dip switches are arranged on the PCB of indoor
invalid.
unit, and must be set based on the following
instructions before test run. The system shall not
be started before the completion of dip switch 7.12.1.2 Setting of Fan Speed
setup. The air volume can be changed by
(a) Address of indoor units (DSW6): All indoor performing external static pressure setup
units must be numbered in sequence based on ("C5") on wired controller. Please refer to the
the diagram below. Outdoor units must be wired controller Installation & Maintenance
numbered from "0". Manual.
Height of Ceiling
DSW6 (Setting 0~63) Ex.) Set address No.16 Setting of Wire
Setting ON
DSW6 09~24 27~54 Controller
ON
Method 1 2 3 4 5 6 OFF
1 2 3 4 5 6 OFF
Note: 8421 coding method No.5 isON 2.7mSG^ 3.2mSG^ C5=00

dS 3.2d6S )#

(b) Refrigeration system cycle No. (DSW5) 3.0~3.5m 3.6~4.2m )#


is required to be set. All are set to OFF
before shipment.

DSW5 (Setting 0~63) Ex.) Set system No.16


DSW5
ON
Setting ON
1 2 3 4 5 6 OFF
Method 1 2 3 4 5 6 OFF
2 Note: 8421 coding method No.5 is ON

115
8. Mini 4-Way Cassette Type
8.1 General Data
Indoor unit Mini 4-Way Cassette Type
AC 1φ,
Model Power supply 220~ AVC-05HJFA AVC-07HJFA AVC-09HJFA
240V/50Hz(60Hz)
kW 1.5 2.2 2.8
Nominal Cooling Capacity kcal/h 1300 1900 2400
Btu/h 5100 7480 9520
kW 2.0 2.5 3.3
Nominal Heating Capacity kcal/h 1700 2100 2800
Btu/h 6800 8500 11220
Cooling Power Consumption kW 0.014 0.014 0.014

Heating Power Consumption kW 0.014 0.014 0.014

Cooling Operating Current A 0.15 0.15 0.15

Heating Operating Current A 0.15 0.15 0.15


Sound Pressure-
Noise Level(Slo/Lo/Me/Hi) 26/28/29/30 26/28/29/30 26/28/30/32
dB(A)
H(mm) 215 215 215
Outer Dimensions W(mm) 570 570 570
D(mm) 570 570 570
Net Weight kg 14.5 14.5 14.8
Air Flow Rate(Slo/Lo/Me/Hi) m3/h 335/370/390/430 335/370/390/430 350/390/430/470
Motor Power W 57 57 57
Piping Connections Flare-nut Connection(with Flare Nuts)
Liquid Line mm φ6.35 φ6.35 φ6.35
Gas Line mm φ12.7 φ12.7 φ12.7
Condensate Drain VP25(Outer Diameter Ø32mm)
Approximate Packing
m3 0.142 0.142 0.142
Measurement
Standard Accessories Suspension Drackets
Panel Model HPE-D-NK
Cabinet Color Neutral White
H(mm) 37 37 37
Outer Dimensions W(mm) 620 620 620
D(mm) 620 620 620
Net Weight kg 2.7 2.7 2.7
Packing Volume m3 0.046 0.046 0.046

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

116
Indoor unit Mini 4-Way Cassette Type
AC 1φ,
Model Power supply 220~ AVC-12HJFA AVC-15HJFA AVC-17HJFA AVC-19HJFA
240V/50Hz(60Hz)
kW 3.6 4.5 5.0 5.6
Nominal Cooling Capacity kcal/h 3100 3800 4300 4800
Btu/h 12240 15300 17000 19040
kW 4.2 5.0 5.6 6.3
Nominal Heating Capacity kcal/h 3600 4300 4800 5400
Btu/h 14280 17000 19040 21420
Cooling Power Consumption kW 0.016 0.022 0.030 0.040

Heating Power Consumption kW 0.016 0.022 0.030 0.040

Cooling Operating Current A 0.16 0.23 0.30 0.39

Heating Operating Current A 0.16 0.23 0.30 0.39


Sound Pressure-
Noise Level(Slo/Lo/Me/Hi) 26/29/32/34 28/31/36/38 31/36/39/42 34/38/42/45
dB(A)
H(mm) 215 215 215 215
Outer Dimensions W(mm) 570 570 570 570
D(mm) 570 570 570 570
Net Weight kg 14.8 15.8 15.8 15.8
Air Flow Rate(Slo/Lo/Me/Hi) m3/h 350/390/430/490 400/424/524/560 424/524/570/660 480/560/650/750
Motor Power W 57 57 57 57
Piping Connections Flare-nut Connection(with Flare Nuts)
Liquid Line mm φ6.35 φ6.35 φ6.35 φ6.35
Gas Line mm φ12.7 φ12.7 φ12.7 φ12.7
Condensate Drain VP25(Outer Diameter Ø32mm)
Approximate Packing
m3 0.142 0.142 0.142 0.142
Measurement
Standard Accessories Suspension Drackets
Panel Model HPE-D-NK
Cabinet Color Neutral White
H(mm) 37 37 37 37
Outer Dimensions W(mm) 620 620 620 620
D(mm) 620 620 620 620
Net Weight kg 2.7 2.7 2.7 2.7
Packing Volume m3 0.046 0.046 0.046 0.046

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

117
8.2 Dimensional Data
Models: AVC-05~19* Unit:mm

570 (Unit Size)


530 (Dimension of Suspension Bolts)

530 (Dimension of Suspension Bolts)


575~595 (Dimension of Opening )
620 (Dimension of Panel )
530 (Dimension of Suspension Bolts)

570 (Unit Size)


570 (Unit Size)

530 (Dimension of Suspension Bolts)


570 (Unit Size)
575~595 (Dimension of Opening )
65

620 (Dimension of Panel )

Drain Pipe

Gas Pipe

Liquid Pipe

Wiring Hole

118
8.3 Selection Data

● Service Space
Models:AVC-05~19*

● Sensible Heat Factor (SHF)


The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.

SHF
Indoor Unit Model
HI ME LO SLO
AVC-05* 0.70 0.68 0.68 0.68
AVC-07* 0.70 0.68 0.68 0.68
AVC-09* 0.64 0.62 0.62 0.62
AVC-12* 0.64 0.62 0.62 0.62
AVC-15* 0.63 0.61 0.61 0.61
AVC-17* 0.63 0.61 0.61 0.61
AVC-19* 0.63 0.61 0.61 0.61

119
● Sound Data
Noise Criteria Curve

Measurement Point: 1.5 Meters Beneath the Unit Power Supply: 220-240V~50Hz/60Hz

Model: AVC-05~07* Model: AVC-09*


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


90 90

80 80

70 70
NC-70 NC-70

NC-65 NC-65
60 60
NC-60 NC-60
NC-55 NC-55
50 50
NC-50 NC-50
NC-45 NV-45
40 40
NC-40 HI NC-40
ME HI NC-35 NC-35
30 30 ME
SLO LO NC-30 NC-30
LO
NC-25 SLO
20 20 NC-25
NC-20 NC-20
10 NC-15 NC-15
10
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVC-12*
Model: AVC-15*
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

90
90

80
80

70 70
NC-70 NC-70
NC-65 NC-65
60 60
NC-60 NC-60
NC-55 NC-55
50 50
NC-50 NC-50
NC-45 HI NC-45
40 HI 40 ME
NC-40 NC-40
ME LO NC-35
NC-35 30 SLO
30 LO NC-30
NC-30
SLO NC-25
NC-25 20
20
NC-20
NC-20
10 NC-15
10 NC-15
63 125 250 500 1k 2k 4k 8k
63 125 250 500 1k 2k 4k 8k

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVC-17* Model: AVC-19*


Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

90 90

80 80

70 70
NC-70 NC-70

NC-65 NC-65
60 60
NC-60 NC-60
NC-55 NC-55
50 50
NC-50 HI NC-50
HI ME
NC-45 NC-45
40 ME 40
NC-40 SLO LO NC-40
LO NC-35 NC-35
30 30
SLO NC-30 NC-30

NC-25 20 NC-25
20
NC-20 NC-20

NC-15 10 NC-15
10
63 125 250 500 1k 2k 4k 8k
63 125 250 500 1k 2k 4k 8k

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)


120
● Temperature Data

AVC-05*

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.4 1.4 1.7 1.7

0.6 0.6 2m 2m

0.3 0.3 0.6 0.6

1m 1m

0.3 0.3

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]


2.7m 2.7m
12 12 40 40

2m 2m

18 18 30 30

1m 28 28 1m
22 20 22
20 26 26

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

AVC-07*

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.4 1.4 1.7 1.7

0.6 0.6 2m 2m

0.3 0.3 0.6 0.6

1m 1m

0.3 0.3

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]


2.7m 2.7m
12 12 40 40

2m 2m

18 18 30 30

1m 28 28 1m
22 20 22
20 26 26

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

121
AVC-09*
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
1.5 1.5 1.9 1.9

2m 2m

0.6 0.6 0.6 0.6

1m 0.3 0.3 1m
0.3 0.3

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
12 12 36 36

2m 2m
18
20 18 20
22 22 30 30
1m 1m
28 28

26 26
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

AVC-12*

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
1.6 1.6 2.0 2.0

2m 2m

0.6 0.6 0.6 0.6

1m 0.3 0.3 1m
0.3 0.3

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]

2.7m 2.7m
12 12 36 36

2m 2m
22 18
20 18 20 22 30
30

1m 1m
28 28

26 26
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

122
AVC-15*

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.8 1.8 2.1 2.1

0.9 2m 2m
0.9 0.9 0.9

0.6 0.6 0.6


0.6
1m 1m
0.3
0.3
0.3 0.3

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]


2.7m 2.7m
12 12 40 40

22 22 2m 2m

18 18 30 30

1m 28 28 1m
20
20
26 26
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

AVC-17*

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.2 2.2 2.3 2.3

2m 2m
0.9 0.9
0.9 0.9

0.6 0.6 0.6


0.6 1m 1m

0.3 0.3
0.3 0.3
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]


2.7m 2.7m
12 12
22 40 40
22
2m 2m
30 30
18 18
1m 1m
20 20
28 28
26 26
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

123
AVC-19*
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.5 2.5 2.5 2.5

0.9 0.9 2m 2m
0.9 0.9

0.6 0.6 0.6 0.6

1m 1m
0.3 0.3
0.3 0.3

0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

Temperature [°C] Temperature [°C]


2.7m 2.7m
12 12 40 40

2m 2m

17 17 30 30

1m 1m
21 19 21
19
26 28 28 26
0m 0m
3m 1.5m 0m 1.5m 3m 3m 1.5m 0m 1.5m 3m

8.4 Component Data

Indoor Heat Exchanger and Fan

Model AVC-05* AVC-07* AVC-09* AVC-12* AVC-15* AVC-17* AVC-19*


Heat Exchanger Type – Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 5.0 5.0 5.0 5.0 5.0 5.0 5.0
Rows – 2 2 2 2 3 3 3
Fin Material Aluminum
Pitch mm 1.3 1.3 1.3 1.3 1.3 1.3 1.3
Maximum Operating Pressure Mpa 4.15 4.15 4.15 4.15 4.15 4.15 4.15
2
Total Face Area m 0.17 0.17 0.20 0.20 0.20 0.20 0.20
Number of Coil/Unit – 1 1 1 1 1 1 1
Indoor Fan Muiti-Blade Centrifugal Fan
Number/Unit – 1 1 1 1 1 1 1
Outer Diameter mm 322 322 322 322 322 322 322
Revolution(220V)
400/435/460/500 400/435/460/500 400/435/480/515 420/450/500/550 480/515/600/650 500/600/650/740 560/650/740/830
(Slo/Lo/Me/Hi) rpm
Nominal Air Flow
3 335/370/390/430 335/370/390/430 350/390/430/470 350/390/430/490 400/424/524/560 424/524/570/660 480/560/650/750
(Slo/Lo/Me/Hi) m /h
Indoor Fan Moter Drip-Proof Type Enclosure
Starting Method – DC Driven
Nominal Output W 57 57 57 57 57 57 57
Quantity – 1 1 1 1 1 1 1
Insulation Class – E E E E E E E

124
8.5 Refrigeration Cycle

Indoor Unit

2
: Refrigerant Flow Direction
(Cooling) : Refrigerant Flow Direction
(Heating) : Field Refrigerant Piping :
3 Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

125
8.6 Electrical Data

Indoor Unit

Unit Main Power Applicable Voltage Indoor Fan Motor


Model
VOL PH HZ Maximum Minimum RNC IPT
AVC-05* 0.25 0.08
AVC-07* 0.25 0.08
Mini AVC-09* 0.25 0.08
4-Way AVC-12* 220~240 1 50/60 264 198 0.25 0.08
Cassette Type AVC-14* 0.25 0.08
AVC-17* 0.25 0.08
AVC-19* 0.25 0.08

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

Safety and Control Device Setting


Indoor Unit

Model AVC-05~19*
For Evaporator Fan
Motor Thermostat Cut-Out ℃ 100±5
Cut-In ℃ 90±15
For Control Circuit
A 5
Fuse Capacity
Freeze Protection
Thermostat
Cut-Out ℃ 0
Cut-In ℃ 14
Thermostat
℃ 2
Differential

126
8.7 Electrical Wiring Diagram
Model: AVC-05~19*

☆ ☆

L
N

:
:
:

☆ :

127
8.8 Indoor Unit Optional Parts
Optional Parts Applied Indoor Unit Type

Type Model mini 4-Way Cassette Type

HYXE-VA01 ●

HYXE-VB01 ●

Wire Remote Control Switch HYXE-J01H ●

HYXE-M01H ●

HYXE-K01H ●

Wireless Remote Control Switch HYE-W01 ●

Duct Adapter HFL-56CSA ●

Wireless Receiver Kit HYRE-Z01H ●

Motion Sensor HPS-MACN ●

7 Day Timer HYDE-E01H ●

HYJE-D01H ●

HYJE-D02H ●

Centrol Station HYJE-H01H ●

HYJ-J01H ●

HYJM-S01H ●

Anion Generator HJK-ELZA ●

Interface for Building Control HCPC-H2M1C ●

HPS-162#E

Drain Pump HPS-132#E

HPS-151#E

HF-224L-FE

Long Life filter HF-280L-FE

HF-40L-ZFE

HP-DB-NK
3D Air Swing
HP-EB-NK

128
8.9

(12ID)

(25ID)

Bolt 2

Sealing Gasket 2

129
8.10 Installtion
8.10.1

2.5
below.
Fan Motor Speed-up
Setting so that uniform air distribution is available.

245mm

130
8.10.2 ●

below.
530 (Dimension of Suspension Bolts)
575~595 (Dimension of Opening )
620 (Dimension of Panel )
570 (Unit Size)

530 (Dimension of Suspension Bolts)


570 (Unit Size)
575~595 (Dimension of Opening )
620 (Dimension of Panel )

below.

50

110

131
(a) For suspended ceiling with panel installed
Put the inspection ruler Put the inspection ruler at
below the indoor unit surface of suspended ceiling

Opening size of inspection ruler


Check the heights of suspended ceiling and
indoor unit at each corner
Check the size of each side

(b) For ceiling without panel


Pattern Board for Installation

e
Siz Ope
ning ning
Ope Size

Suspension Bolt

Indoor Unit

Bolt (M6)
Surface of Ceiling
Pattern Board for Installation

(1) Removing Air Intake Grille from Air Panel


Step 1
Remove the air intake grille. Push the grab of air intake
grille away in the direction of arrow as shown in the figure,
and open the air intake grille until its angle to panel surface
(1) The pattern board for installation is in the is approx. 45°. Panel
packing carton. Please cut it off. Air Intake Grille

Inspection Ruler

Corner Plate (×4)

Pattern Board for Installation Crab


Package (Corrugated Board)
4.9 Mounting Indoor Unit * Slide the knobs toward the allow direction

(2) Adjust the indoor unit to the correct position Fig. Method for Removal of Air Intake Grille
using the factory-supplied inspection ruler
NOTE
5~10

Ceiling * Do not touch the air louver during installation work.


* Do not try to remove the grille while it is at an angle of 90o
5~10 5~10 Indoor Unit from the surface of the air panel.

Step 2
Surface of
Hold the slope while putting up the air intake grille.
Flange Surface Step 3
5~10

Indoor Unit Suspended


(Bottom View) Ceiling Draw the air intake grille out forward.

132
Step 4
(2) Installing Air Panel Make sure the distance between bottom surfaces of indoor
unit and ceiling is 30mm (see Fig 2.4 below).
Step 1
Remove the corner plate. Pull part ① in the direction of
arrow shown in the figure below to remove the corner plate.

Suspension Leg
(Indoor Unit)

30
Indoor Unit

Ceiling
Long Bolt
Corner Plate

Fig. Side View of Panel

Fig. 2.2
● Fasten the long bolts. The inadequate fastening of long
Step 2 bolts for panel may result in the defects shown in the
Please adjust and align the point indicating "Ref. Pipe figure below.
Refrigerant Piping" on panel to the refrigerant piping of indoor
Air Leak
unit.

Step 3
Please fasten the panel to the suspension leg of indoor unit
Dirt
through long screws (M6, cross) delivered as panel
accessories. Condensation

● Please adjust the body height of indoor unit if there is


still a gap between panel and ceiling after the adequate
fastening of long bolts for panel.

Indoor Unit

Hook

Electric Box No Gap Allowable

● The indoor unit body height can be directly adjusted via the
corner hole of properly fastened panel provided that the
indoor unit body levelness and drain pipe, etc. are not
Panel affected.

Long Screw Refrigerant Piping


(×4) Marked with "Ref. Pipe"

Fig. Installation ※ Please note that excessive adjustment of body height may
cause water to run out of water pan.

133
8.10.3 Wiring of Panel 8.10.4 Test Run
Step 1 The installed panel shall be subjected to test run as per the
The panel is designed with the coupling shown in the figure Installation & Maintenance Manual.
below. Tear off the adhesive tape fixing the coupling, lead it
out and connect it to the body coupling as shown in the figure
8.10.5 Louver Adjustment
below.
Step 1
Motor wiring for Please turn on main power supply.
automatic air Step 2
deflector (panel
Please press the " " (ON/OFF) key on remote control
side) (20-pin white
coupling used for to bring the machine into operation.
light-current Step 3
applications)
Press " " or " " key, and select " " (Auto Swing). The
louver begins to swing automatically. Press the key again,
and the louver will stop swinging.
Motor wiring for
automatic air Step 4
deflector (boy side) LCD screen shows the location of louver in real time.
(20-pin white
coupling used for
(Auto Swing)
light-current
applications)

Please turn power off before the connection of coupling,


since the connection of coupling without power supply
Continuous Change of Position
turned off may result in malfunction of auto-turning louver.
Step 2
Install the air intake grille upon completion of wiring. Mount (Louver position fixed)
the strap hook of part ① in panel hole during installation as
described in Section 2.2. The air intake grille can be
installed in any of the 4 directions by rotating it. Where
several indoor units are installed simultaneously, the air Show Location of Louver
intake grille installation direction can be freely selected.

● Appropriate air flow direction is dependent on the


mounting position, room structure, and furnishings, etc.
Please adjust the air flow direction in the case of poor
refrigeration or heating effect.
● The louver location displayed on LCD may be different
from its actual location. The louver location shall be set
based on the location displayed on LCD when the louver
angle is fixed.
● The louver will not stop immediately when auto swing is
stopped by pressing " " or " " key.

Through Hole in Panel


● Refrigeration in a space where the humidity is higher than
Strap 80% may result in condensation on panel and louver.

134
135
136
137
Fig. Electrical Wiring Connection for Indoor Unit

Specifications of Power Cords for Field Connection, Electrical Parameters of Indoor Unit, and Wire Size

(kBtu/h)

05~07 0.20A
09 0.20A
12 0.30A
15 0.35A
17 0.42A
19 0.56A

Note:
(1) Field wiring shall be in conformity to local laws and regulations, and all wiring operations must be
performed by qualified professionals.
(2) Refer to relevant standards for above-noted power cord size.
(3) Where power cord is connected through junction box in series, be sure to determine the total
current and choose wires based on the table above.
(4) 4) As a minimum, the chosen power cord shall be compliant w requirements on neoprene
sheathed wire #57 as stated in IEC60245-1, while the power cord shall be made from copper
conductor.
(5) The wiring specifications for weak-current communication circuit shall not be lower than that for
RVV(S)P shielded wires or equivalent, and the shielding layer shall be grounded.
138
8.14 Test Run
Test 『un should be perfo 『med acco 『ding to the
Installation & Maintenance Manual.

:$51,1*

• Do no operate the system until all the check points • Pay attention to the following items while the system
a 『e clea『ed. is 『unning.
(A) Check to ensure the electrical 『esistance between (A) Do not touch any of the pa门s by hand at the
te 『minal and ground is more than 1 MO. If this is discha 『ge gas side, since the temperatures of
not the case, do not operate the system until the comp『essor chamber and the pipes at the
electrical leakage is found and 『epaired. discha 『ge side a『e higher than 90 。C.
(B) Check to ensure the stop valves of outdoor unit a 陀 (B) DO NOT PUSH THE BUTTON OF THE AC
fully opened, and then start the system CONTACTOR. It will cause a serious
(C) Check to ensu 陀 the switch on main powe『 source accident.
has been ON for mo 『·e than 4 hours to
warm the comp陀sso 『 by heater.
͓ 3URWHFWLRQ &RQWURO'HYLFHV

Indoor Unit

Capacity of Indoor Unit kBtu/h 05~19

Capacity of Fuse on Indoor Unit Control


' 5
Circuit

Cut-out °C 0
Freeze Protection
Temperature Cut-in °C 14
Set Temperature Difference °C 2

139
(3) 6 dip switches are arranged on the PCB of indoor
unit, and must be set based on the following
instructions before test run. The system shall not
be started before the completion of dip switch
setup.
(a) Address of indoor units (DSW6): All indoor
units must be numbered in sequence based on
the diagram below. Outdoor units must be
numbered from "0".
DSW6 (Setting 0~63) Ex.) Set address No.16
DSW6
Setting ON
ON
Method 1 2 3 4 5 6 OFF
1 2 3 4 5 6 OFF
Note: 8421 coding method No.5 isON

(b) Refrigeration system cycle No. (DSW5)


is required to be set. All are set to OFF
before shipment.

DSW5 (Setting 0~63) Ex.) Set system No.16


DSW5
ON
Setting ON
1 2 3 4 5 6 OFF
Method 1 2 3 4 5 6 OFF
2 Note: 8421 coding method No.5 is ON

140
8.16

8.16.2

8.16.1

Step 1
Remove the air intake grille. Push the grab of air intake 8.16.3
grille away in the direction of arrow as shown in the figure,
and open the air intake grille until its angle to panel surface
is approx. 45°.

Panel
Air Intake Grille

Corner Plate (×4)

Grab

Fig. Method for Removal of Air Intake Grille

Please don't attempt to pull out the air intake grille when its
angle to panel surface is 90°.

Step 2
Hold the slope while putting up the air intake grille.
Step 3
Draw the air intake grille out forward.

141
8.17

8.17.1

8.17.2

8.17.3

8.17.4

142
9. Ceiling & Floor Type(AVV)
9.1 General Data
Indoor Unit Type Ceiling & Floor Type
Model AC 1 , 220-240V/50Hz AVV-17URSCA AVV-18URSCA AVV-22URSCA AVV-24URSCA
Power Supply AC 1 , 220V/60Hz AVV-17UR2SA AVV-18UR2SA AVV-22UR2SA AVV-24UR2SA
Nominal Cooling kW 5.2 5.8 6.5 7.3
Capacity *1) kcal/h 4,500 5,000 5,600 6,300
Btu/h 17,700 19,800 22,200 24,900
Nominal Cooling kW 5.0 5.6 6.3 7.1
Capacity *2) kcal/h 4,300 4,800 5,400 6,100
Btu/h 17,100 19,100 21,500 24,200

Cooling Power Consumption kW 0.04 0.04 0.07 0.07


Nominal Heating kW 5.6 6.5 7.5 8.5
Capacity kcal/h 4,800 5,600 6,500 7,300
Btu/h 19,100 22,200 25,600 29,000

Heating Power Consumption kW 0.04 0.04 0.07 0.07


Sound Pressure Level
(Ceiling Type)
(Overall A Scale) dB 39-35-30 39-35-30 45-41-37 45-41-37

Sound Pressure Level


(Floor Type)
(Overall A Scale) dB 43-38-35 43-38-35 48-44-40 48-44-40
Outer Dimensions
Height mm 230 230 230 230
(in.) (9) (9) (9) (9)
Width mm 990 990 990 990
(in.) (39) (39) (39) (39)
Depth mm 680 680 680 680
(in.) (26-3/4) (26-3/4) (26-3/4) (26-3/4)
Net Weight kg 31 31 32 32
(lbs.) (68) (68) (70) (70)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 780/660/540 780/660/540 966/840/678 966/840/678
(Hi/Me/Lo) (cfm) (459/389/318) (459/389/318) (569/495/399) (569/495/399)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ9.53 Φ9.53
(in.) (1/4) (1/4) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88
(in.) (5/8) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.31 0.31 0.31 0.31
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.0 Meter Beneath the Unit. 1.0 Meter from Discharge Grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

143
Indoor Unit Type Ceiling & Floor Type
Model AC 1 , 220-240V/50Hz AVV-27URSCB AVV-30URSCB AVV-38URSCB AVV-48URSCC
Power Supply AC 1 , 220V/60Hz AVV-27UR2SB AVV-30UR2SB AVV-38UR2SB AVV-48UR2SC
Nominal Cooling kW 8.7 9.3 11.6 14.5
Capacity *1) kcal/h 7,500 8,000 10,000 12,500
Btu/h 29,700 31,700 39,600 49,500
Nominal Cooling kW 8.4 9.0 11.2 14.2
Capacity *2) kcal/h 7,200 7,700 9,600 12,200
Btu/h 28,700 30,700 38,200 48,500

Cooling Power Consumption kW 0.07 0.08 0.13 0.16


Nominal Heating kW 9.6 10.0 13.0 16.3
Capacity kcal/h 8,300 8,600 11,200 14,000
Btu/h 32,800 34,100 44,400 55,600

Heating Power Consumption kW 0.07 0.08 0.13 0.16


Sound Pressure Level
(Ceiling Type)
(Overall A Scale) dB 43-39-34 45-40-36 51-46-40 50-46-42

Sound Pressure Level


(Floor Type)
(Overall A Scale) dB 46-41-37 48-43-39 54-49-43 55-50-46

Outer Dimensions
Height mm 230 230 230 230
(in.) (9) (9) (9) (9)
Width mm 1285 1285 1285 1580
(in.) (50-3/5) (50-3/5) (50-3/5) (62-1/5)
Depth mm 680 680 680 680
(in.) (26-3/4) (26-3/4) (26-3/4) (26-3/4)
Net Weight kg 39 40 41 47
(lbs.) (86) (88) (90) (103)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 1092/912/732 1164/978/798 1488/1230/978 1980/1680/1380
(Hi/Me/Lo) (cfm) (643/537/431) (685/576/470) (876/724/576) (1166/989/812)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53
(in.) (3/8) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88
(in.) (5/8) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.40 0.40 0.40 0.48
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.0 Meter Beneath the Unit. 1.0 Meter from Discharge Grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

144
9.2 Dimensional Data

Models: AVV-17~24*

Unit:mm

104
177
91 17

43
230 39 912 39
990

680

680

261
182

174
10 101

66 88 16 88
43

22
184

Models: AVV-27~38*

Unit:mm
41 108
177

95 16

1285 230
680

680

261
182

174
10 101

22

66 88
43

16 88
184

Models: AVV-48*

Unit:mm
44 101
177

92 16

230
1580
680
680

261
182

174
10 101

66 88
22
43

16 88
184

145
9.3 Selection Data
● Service Space
Models: AVV-17~48*

50
100

300 500

● Sensible Heat Factor (SHF)


The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.

SHF
Indoor Unit Model
Hi Me Lo

AVV-17* 0.71 0.68 0.64


AVV-18* 0.71 0.68 0.64
AVV-22* 0.73 0.69 0.66
AVV-24* 0.73 0.69 0.66
AVV-27* 0.74 0.69 0.65
AVV-30* 0.76 0.71 0.68
AVV-38* 0.75 0.70 0.66
AVV-48* 0.76 0.72 0.69

146
● Sound Data

Model: AVV-17* Power Supply: 220-240V/50Hz,220V/60Hz Model: AVV-18* Power Supply: 220-240V/50Hz,220V/60Hz
Measurement Point: 1.0 Meters Beneath the Unit Measurement Point: 1.0 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve

80 80
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


70 NC-70 70 NC-70

60 NC-6 60 NC-6
0 0

50 NC-5
0 50 NC-5
0

Hi Hi

40 Me NC-4
0
40 Me NC-4
0

30 NC-3
0
30 NC-3
0

20 Approximate NC- 20 Approximate NC-


Threshold of 20 Threshold of 20
Lo Lo
Hearing for Hearing for
Continuous Noise Continuous Noise
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVV-22* Power Supply: 220-240V/50Hz,220V/60Hz Model: AVV-24* Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.0 Meters Beneath the Unit Measurement Point: 1.0 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve

80 80
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

70 NC-70 70 NC-70

60 NC-6 60 NC-6
0 0

50 Hi NC-5
0 50 Hi NC-5
0

Me Me
40 NC-4
0
40 NC-4
0

30 NC-3
0
30 NC-3
0

20 Approximate NC- 20 Approximate NC-


Threshold of 20 Threshold of 20

Hearing for Lo Hearing for Lo


Continuous Noise Continuous Noise
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

147
Model: AVV-* Power Supply: 220-240V/50Hz,220V/60Hz Model: AVV-0* Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.0 Meters Beneath the Unit Measurement Point: 1.0 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve

80 80
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


70 NC-70 70 NC-70

60 NC-6 60 NC-6
0 0

Hi
50 Hi NC-5 50 NC-5
0 0

Me Me

40 NC-4
0 40 NC-4
0

30 NC-3
0 30 NC-3
0

Lo
20 Approximate Lo NC- 20 Approximate NC-
Threshold of 20 Threshold of 20
Hearing for Hearing for
Continuous Noise Continuous Noise
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVV-* Power Supply: 220-240V/50Hz,220V/60Hz Model: AVV-* Power Supply: 220-240V/50Hz,220V/60Hz
Measurement Point: 1.0 Meters Beneath the Unit Measurement Point: 1.0 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve

80 80
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

70 NC-70 70 NC-70

60 NC-6 60 NC-6
0 0
Hi
Hi

50 NC-5
0 50 NC-5
0
Me Me

40 NC-4
0 40 NC-4
0

30 NC-3
0
30 NC-3
0
Lo

Lo
20 Approximate NC- 20 Approximate NC-
Threshold of 20 Threshold of 20
Hearing for Hearing for
Continuous Noise Continuous Noise
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

148
9.4 Component Data

Indoor Heat Exchanger and Fan

Model AVV-17* AVV-18* AVV-22* AVV-24*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 3 3 3 3
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.22 0.22 0.22 0.22
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2 2
Outer Diameter mm 161 161 161 161
Revolution (220V) rpm 850/745/630 850/745/630 1035/910/800 1035/910/800
Nominal Air Flow m3/h 780/660/540 780/660/540 966/840/678 966/840/678
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - DC Driven
Nominal Output W 40 40 100 100
Quantity - 1 1 1 1
Insulation Class - E E E E

Indoor Heat Exchanger and Fan

Model AVV-27* AVV-30* AVV-38* AVV-48*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 3 3 3 3
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.30 0.30 0.30 0.39
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 3 3 3 4
Outer Diameter mm 161 161 161 161
Revolution (220V) rpm 920/790/660 980/835/720 1210/1010/835 1200/1045/890
Nominal Air Flow m /h
3
1092/912/732 1164/978/798 1488/1230/978 1980/1680/1380
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - DC Driven
Nominal Output W 140 140 140 181
Quantity - 1 1 1 1
Insulation Class - E E E E

149
9.5 Refrigeration Cycle

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

150
9.6 Electrical Data

< 50 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVV-17URSCA 0.18 0.04
AVV-18URSCA 0.18 0.04
AVV-22URSCA 0.32 0.07
Ceiling & AVV-24URSCA 0.32 0.07
220~240 1 50 264 198 1
Floor Type AVV-27URSCB 0.32 0.07
AVV-30URSCB 0.36 0.08
AVV-38URSCB 0.59 0.13
AVV-48URSCC 0.73 0.16

< 60 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT

AVV-17UR2SA 0.18 0.04


AVV-18UR2SA 0.18 0.04
AVV-22UR2SA 0.32 0.07
Ceiling & AVV-24UR2SA 0.32 0.07
220 1 60 242 198 1
Floor Type AVV-27UR2SB 0.32 0.07
AVV-30UR2SB 0.36 0.08
AVV-38UR2SB 0.59 0.13
AVV-48UR2SC 0.73 0.16

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

Safety and Control Device Setting


Indoor Unit

Model
AVV-17~48*

For Evaporator Fan


Motor Thermostat ℃ 130±5
Cut-Out
Cut-In ℃ 83±15
For Control Circuit
Fuse Capacity
A 5
Freeze Protection
Thermostat ℃ 0
Cut-Out
Cut-In ℃ 14

Thermostat
℃ 2
Differential

151
9.7 Electrical Wiring Diagram
Model: AVV-17~48*
HEAT PUMP

WARNING Before inspecting the electrical parts


PCB2
TB1 MIF set the Operation Switch to OFF,
L EFR1 DM PCN203 and cut OFF the power supply.
Z1 Noise ☆ Air Panel
N Filter
DCL Z2
DSA Supply Name
PCN201 Circuit
CN1~26,39~202
CN201 CN27~38
PCN202 CN202
C
* On y For DSW3,5
48K(5HP) CN38※ DCL
CN36
EF
MIF
PCB1 MS
MV
PCN7 PCN1 CN1 CN19 CN17
PCB1,2
CN11 Alarm
PCN1~203
RSW
H2 TB1,2
TF
YH2

PCB2 DCL Note :
TF
1.All the field wiring and equipment
PCB1 must comply with local codes.
TB2 TB1 2.※Optional,no impact on the performance
Receiver kit of air conditioning.

152
9.8 Indoor Unit Optional Parts

Optional Parts Applied Indoor Unit Type

Type Model Ceiling & Floor Type

HYXE-F01H ●
HYXE-G01H ●
Wire Remote Control Switch HYXE-A01H#01 ●
HYXE-J01H ●
HYXE-M01H ●
Wireless Remote Control Switch HYE-L01
HYE-W01 ● Standard Option
HYRE-V01H
HYRE-T01H
Wireless Receiver Kit
HYRE-V02H
HYRE-X01H
7 Day Timer HYDE-E01H ●
HYJE-H01H ●
HYJE-D02H ●
HYJ-J01H ●
Centrol Station HCCS-H128H2C1YM ●
HCCS-H128H2C1NM
HCCS-H247R4C1E
HCCS-H128H2C2NM ●
HC-A64BNP ●
Interface for Building Control
HCPC-H2M1C ●
HPS-162#E
Drain Pump HPS-132#E
HPS-151#E
HF-224L-FE
Long Life filter HF-280L-FE
HF-40L-ZFE
HP-DB-NK
3D Air Swing
HP-EB-NK

153
9.9 Factory-Supplied Accessories
#N,&19,'/&/1-1:*&%,&%0*&)*('.&+,9*)(;&3*8,)*
4'8%'.:&,)&-,9'.:&%0*&'./,,)&2.'%;&@2%&1&+4,%0&,. Fixing screw

%0*&)*('.&+,9*)(6 of side cover

kfflUWX^
mpno\
kfflUWX
mn[o
Inside of resin side cover
The three hooking parts and one hooking plate
should be mounted when recovering resin side cover

Fig. Removing the air inlet grille


and resin side cover

# Remove the fixing adhesive tape on the fan snail


shell and outer panel befor installation.The tape
is just used for fixing during transportation.

Fig. Side Covers

# Remove the air inlet grille and resin side cover


befor installation.

Remove the air inlet grille


(1) Open the air inlet grille after removing screw covers
and fixing screws as is shown in Fig. below.
(2) Remove fixing screws of air inlet grille .
(3) Carefully push the air inlet grille away from the.
mounting plate of indoor unit. Two tapes on
Each fan snail shell
(4) Remove the air inlet grille .

Remove the resin side cover Two tapes on


Each fan snail shell
(1) Remove fixing screw of side cover.

#N0*&-*+01.'(-&,8&%0*&12%,-1%'+&(I'.:&4,29*)
(2) Carefully push the side cover away from the
indoor unit approximately 10mm forward.
'(&2%'4'>*/6&&?,&.,%&-,9*&%0*&(I'.:&4,29*)&3C
(3) Remove the resin side cover .
01./&,)&,%0*)&,3S*+%(6&&N0'(&+1.&/1-1:*&%0*
-*+01.'(-&,8&%0*&12%,-1%'+&(I'.:&4,29*)6

Push Fixing screw


forward
of side cover
Fixing screws
Push forward
of air inlet grille

Removing the air inlet grille


and resin side cover

154
of Drain Pipe Connection

Drain Pipe Connection

Packing For Covering Clamp


(10T×38×165) of Drain Pipe Connection

Wireless Remote For Controlling the


Control Switch Unit

155
9.10 Installation
9.10.1 Initial Check
679
9 87 789 89
  

7 %$8 "9
  8 
& 
 9
8
around the indoor unit with a proper clearance 879
  9
8 8
  4
working space,as shown below. # 79 879
9 87 789 87

87&
abbc   897  $
  8  89 89
ceiling
  9 9 87 7894
' 8 8 89 7 9 
9 (
7
9"& 87 9 87 789 
7

Z[

7 
& 
7 87 9 9 
 "

WXYZ[200 WXYZ[300 9 
98 
9  9 87 7894
)
&
997987 9 9  87 879 7 9
87 789 8 879
 87
89
 9

8 898  9
  978 
$ 
8
*879 94
+%,# 79 879
9 87 789  9
 9
798 
$ 8 89 & 
8
9 9
WXYZ[_]]

WXYZ[100
WXYZ[\]] 9  98
"( 9 79 
"  
9 79 894
+-,679
9 87 789
7 779



 
98

9 
9 . 9  9
 9
798 
$ 
8
94
+ ,)

9 "(
7 879
9 9
For ceiling installation

WXYZ[200 WXYZ[300 79 89 87 894 )



9 789
9"
7 8 9 9 79 
"  87 894
'7 779 9 7 8 89 9 "(

7 9 9"4
+#,679

78 8 9 7 9   &
89 
 784
'
$8
7& 8$
987 9 9 
9
(
7  79 879
9 87 789 87
7

8 

87 7$87794
WXYZ[150

[
WXYZ[_]]

wall /012345641789:1450;54501479<=1:46>4=1?6@4A8
@A50A74BCD3EF2<DC44G501:@A814A54<;H42;981
WXYZ[\]]

I;7E1:48A59;5A674A>45014:1>:AE1:;754A74501
G95I66:4J7A54?1;384A75645014:66<4@01:1450A8
K7I66:4J7A54A84A785;??1IC
OP65;?4Q1>:AE1:;754R9;75A5H4S1:46714G95I66:4J7A5T
OU6?9<146>45014:66<4@01:1450A8 T VBCD3EF<
floor
WXYZ[150

D
K7I66:4J7A54A84A785;??1IC
For wall mounted installation K74I15;A?L4:1>1:45645014K785;??;5A674M;79;?4>6:
Fig. Operation and Maintenance Space 695I66:497A5C
or wall

 78 9
8 898"987  9 87 789
9 9 
  9 
7  9
89
" 

987  9
9 78
8 9
9 87 9
 
7 " "9
874
# 79 879


"  
9 87 9 $8

  9 87 7894

156
9.10.2 Installtion ●
● Mounting of Suspension Bolts
Step1
Select final location and installation direction of
the indoor unit paying careful attention to the space
(The nut is unnecessary if the unit
for the piping,wiring and mantenance. is installed against the ceiling)
Step2
Mount suspension bolts,as shown in Fig.below.
*For Concrete Slab *For Steel Beam
ceiling or wall
UXV<HE<UYV@@ ;BL>FH
OUVV<HE<UXVZ[W

160

230
IEBCF>H>
JH>>G
ABCDEF<=EGH ;<=>?@ For ceiling installation
OPQRS<EF<TUVW
JKLM>BLNEB<=EGH
OPQRS<EF<TUVW
Fig. Mounting of Suspension Bolts
● Installation Pattern

is in the packing If expansible bolt used


deepen the bolt into
carton of indoor unit. concrete 50--60mm to
Use it to decide an installation location and prevent loose
direction of the unit. Keep distance
between bottom Install the unit
(2) Press the Pattern Board tightly onto the of the unit and floor against the wall
surface , draw out the hole position
for suspension bolts with a pencil. For wall mounted installation
Ceiling Pattern Board Wall Pattern Board

Wall the resin covers.


Floor

For ceiling installation For wall mounted installation

Fig. Pattern Board

9 i 
17-24 912 990

27-38 1207 1285

48 1502 1580

Air outlet side

157
(4) Adjusting of the Unit Level

For ceiling installation

(Min. 10mm)
Keep horizontal

The unit should be installed so that the drain View from front
piping connection side of the unit is slightly
Fig. Inclination of Unit for Drain
(Min. 10mm) lower than the other side ,in order
to avoid the incorrect position of the drain for wall mounted installation
dicharge.

(2)
(Min. 10mm)

completed.
< Lower

hN>f<F̀E@<_N[DH
(Min. 10mm)
<< Lower

drain piping
connection
side

hN>f<F̀E@<bFEBH
Fig. 6 3  39 69 6: 3 6 9633
for ceiling installation

For wall mounted installation


The unit should be installed so that the bottom
of rear side inclines towards the wall slightly.
(Min. 10mm)
The unit should be installed horizontal viewed
from front.

<
Closer
(Min. 10mm)

hN>f<F̀E@<_N[DH

158
9.11 Refrigerant Piping Work 8H9+,-,./0C5:D0I2;JE25?0@,?4
Knock out
hole

686789
68 59  686789
68 64
   8
6
6  6 6 68 68
7 !! "6 #9 $
69  6
86789
68 6%6 6878!9
 6 
6
6 8  98& 9
  6 4'66 67
6 _V`Y aWbcWdY
866 86!6#
68$ #  $6 piping piping

69 4( 986!!6 #6# 


!866# 98 9 8
6 886789
68 "6
$6#78 66 67 6 4 Drain piping Drain Piping Connection
in drain pan

9.11.1 Piping Materials


8I9+,-,./0C5:D0K--450@,?4
809+54-25406:;266<=7>--6,4?0;:--450-,-47* Knock out

829@464;303A40-,-,./07,B40C5:D03A40C:66:E,./ hole

32F64*
Table Piping Size
aWbcWdY
DD08,.*9 piping
1:?46 Ž270+,-,./ ,>,?0+,-,./ _V`Y
0 17-18 ‡0)*ˆˆ 8)‰ˆ9 ‡Š*‹) 80‰Œ9 piping

22-30 ‡0)*ˆˆ 8)‰ˆ9 ‡*)‹ 8‹‰ˆ9


‡0)*ˆˆ 8)‰ˆ9 ‡*)‹ 8‹‰ˆ9
38-48
8L9+,-,./0C5:D0M,/A30@,?40L:N45
8‹9@464;30;642.0;:--450-,-47*0012J407>54 Knock out hole

3A4540,70.:0?>7302.?0D:,73>540,.7,?4*00I6:E
3A40,.7,?40:C03A40-,-470E,3A0.,35:/4.0:50?5<
2,5l03:054D:N402.<0?>730:50C:54,/.0D2345,267
F4C:540;:..4;3,./0-,-47* Right resin
side cover
Knock out
hole for drain piping
9.11.2 Piping Connection
809+:7,3,:.0:C0-,-,./0;:..4;3,:.0,707A:E.0,. 829+,-,./0E:5J07A:>6?0F40-45C:5D4?0C5:D03A4
Fig.
bottom side of the unit.Open the air inlet
_V`Y aWbcWdY grille and remove the resin side cover before
piping piping
the piping work.

P View
Drain Piping

Cut out the knock-out hole along the groove in the


Right Side Cover using saw blade to avoid sharp
edges if piping from right side.
Seal the clearance around pipes with seal material
to prevent ingress of dirt and protect wires from
damage by sharp edge after piping and wiring .

Air inlet grille


P View

Fig. Piping Connection of indoor Unit

159
9.12
(3)
below.

Flaring Dimension
Perform the flaring work as shown below.
+0
Diameter A -0.4
d R410A R407C
6.35 9.1 9.0
9.53 13.2 13.0
12.7 16.6 16.2
15.88 19.7 19.4
19.05 (*) 23.3

O>*(A,71/7'/(/.'*2,.&1(&+(/'7.1(?.?.13(2&11*2,.&1
(*)It is impossible to perform the flaring work with
.A('.3>,(A./*(7A(=.*C*/(+'&<(,>*(/.A2>7'3*(3'.99*A4
1/2H material. In this case, use an accessory
P&C*=*'J(.,(271(B*(?*'+&'<*/(+'&<(,>*(9*+,(A./*
pipe(with a flare).
C>*1(,>*(9*+,(A./*(2&11*2,.&1(.A('*Q:.'*/(/:*(,&
(4)
,>*(B:.9/.13(2&1A,':2,.&14
below. "0$%&'(;.3>,(-./*(0&11*2,.&1
(A ) Insert the Drain Pipe Connection into Drain
Boss with clamp until the connection reaches
the end of the drain pan.
(B ) Insert the Drain Hose and Drain Pipe with
clamps sequently until reaching the end.
"0$O.3>,*1(,>*(A2'*C(+&'(,>*(>&A*(297<?(.1
order to hold the hose around the drain
connection without any leakage of drain
water as shown below.
"6$Fclamp
1A:97,to*(,prevent
>*(/'7.1any
(>&Acondensation
*(7'&:1/(,>*(as>&A*
shown below.
Clamp of Drain
Pipe Connection

Drain Pipe

m`UWdn^Tlo Connection

Drain Hose cYT_XdZ`UU


m`UWdn^Tlo Thermal Insulation
for Clamp

jk t[kWU_hWd_UdX`dXWpWUUTYus
\XUW]Y^lT
TV_`^dX jkWYlT^d\XU]^TV_`X
c_YWpVdVkWdUpYWqd̀rdk`UW
p^Tlod]oqTY[dV̀doYWhWXV
VkWdUpYWqdrY`ldV̀]pk_Xb
VkWdr_^VWYs
cYT_Xda_oW t[kWU_hWd_UdX`dXWpWUUTYus
Bend Drain Pipe inside Side Cover
(5) For Side Cover Connection

Fig. Connecting Drain Piping

160
"#$%&'()*+,(-./*(0&11*2,.&1 /012344567849:;:<=;84:>8?849
cYT_XdZ`UU STXde]XXWY STXdg`V̀Y /@1>=5?;=5:;:?3ABC84BA:6DA3=8E5:/>F:GF:21
7HI5:J87D:;4:3H75=:E8;K575=:3L:0MKKF
(VP25)
cYT_Xda^]b /O1>;B:;77547834:73:7D5:?3P87834:3L:7D5:E=;84
?8?5F::Q55?:7D5:E3J4RPA3?5S:0TM2:73:0T
eWTYdf_[W 0NNF::<3:437:6=5;75:;4:H??5=:PA3?5:3=
=8P5:L3=:7D5:E=;84:?8?849F
/21U5;A:7D5:6344567849:?;=7:3L:7D5:E=;84
STUVWXWY ?8?5:IB:HP849:7D5:J;75=R?=33L:6DA3=8E5
ZTX[ 7B?5:P5;A849:K;75=8;AF
\a^
XU]]b^TV_`X /<1V=;?:7D5:84PHA;7834:K;75=8;A:;=3H4E:7D5
6344567849:?;=7:?5=L567ABF
cYT_Xda^]b /W1X;P754:7D5:E=;84:?8?5:73:7D5:6344567849
?;=7:J87D:7D5:L;673=BRPH??A85E:6A;K?F
hijklmnopq hi jklmnopq
rsttkjjiuvw
Fig. Drain Plug l
Clamp
rsttkjjiuvw r
st tkjjiuvw
Remove the drain plug of the left-side drain boss |}kuponl~zjno€yiz
xuoyzl{ijj rsttkj jiu
vw r‚yknƒ„qqnykw
as indicated in the following procedure
s}kjy†klyj
xuoyzl
hi jk „ktukliŠzŠou
zilzktkjjouv‹ jniqk‹
…inv†yzvn
"D$0:,(,>*(+7A,*1*'4 m}niuykl…yqk
rVP25
"E$;*<&=*(,>*(.1A:97,.&1(<7,*'.794 ‚yknƒ„qqnykw
"0$;*<&=*(,>*(/'7.1(?9:34 s
zil}zkkjtyk†kjjlyojuv‹
"6$F1A*',(,>*(/'7.1(?9:3(.1,&(,>*('.3>,@A./* rsttkjjiuvw
Drain Pipe Connection
|}kuponl~zjno€yiz
drain boss by using a driver as shown rsttkjjiuvw
below.

iX_Vdf_[W ~zjno€yiz
hijklmnopq
r‚ot€iuvƒ„qqnykw
cY_hWY cY
a^]Tb_Xd cYT_XdZ`UU Fig. Wrapping Insulation Material

/X1<3:437:6344567:7D5:E=;84:?8?5P:J87D
Fig. Inserting Drain Plug
P;487;=B:3=:P5J;95:3=:;4B:37D5=:E=;84;95
"I$D+,*'(.1A*',.13(,>*(/'7.1(?9:3(.1,&(,>* ?8?5F
'.3>,@A./*(/'7.1(B&AAJ(A*79(,>*(K&.1,*/(?7', /\1VD54:84P7;AA849:7D5:?8?5S:E3:437:785:7D5
BG(:A.13(7(C7,*'@?'&&+(2>9&'./*(,G?* E=;84:?8?5:;4E:=5L=895=;47:?8?5:73957D5=F
A*79.13(<7,*'.79(71/(A*2:'*(.,(C.,> /]1@L75=:63K?A57849:7D5:E=;84:?8?5:J3=^S
+7A,*1*'4 ?3H=:J;75=:8473:7D5:E=;84:?;4:;4E:6D56^
73:54PH=5:7D;7:J;75=:6;4:LA3J:PK337DABF
fWT^dgTVWY_T^

cYT_Xda^]b

Fig. Sealing Joint Part

"%$M'7?(,>*(.1A:97,.&1(<7,*'.79(7'&:1/(,>*
/'7.1(2&11*2,.&14
"N$0&11*2,(,>*(/'7.1(>&A*(,&(,>*(9*+,@A./*
/'7.1(2&11*2,.&1(7A(,>*(A7<*(7A(,>*
'.3>,(A./*(/'7.1(2&11*2,.&1(?'&2*/:'*4
Fig. Drain Piping

161
9.13 9.13.1

9.13.2

Fig below.

Hole for Power


Draw out the electrical Source
box cover toward the Hole for Transmission
arrow direction Wiring

Fig. Remove electrical box cover

162
The edge of electrical box cover should
be embeded in electrical box.
The edge should not cut Wired Remote Control Switch and Wireless Remote Control
wiring in electrical box.
Switch can not be used simultaneously .If Wired Remote
Electrical box cover
Control Switch is connected ,Disconnect Wireless Receiver
Wiring on the right side as viewed from the discharge grilles
(refrigerant piping connection side ).
Draw in the electrical
box cover toward the
arrow direction

Electrical box

Fig. Recover electrical box cover

Remove the right resin side cover and


DCL
Disconnect Wireless Receiver wiring
TF PCB2 (10-Pole Connector)

Fig. Disconnect Wireless Receiver wiring


PCB1
9.14

Cord clamp
for power
source
wires
Cord clamp
for transmission
wires
TB1

220-240V
50Hz
220V 60Hz

Fig.

Before electrical wiring work, turn OFF the power source.


If the connectors are connected without turning OFF the
power source, the auto-swing louver can not activate.

163
9.15
9.15.2
9.15.1

Use an ELB (Electric Leakage Breaker).If not


used ,it will cause an electric shock or a fire.
Run through the cables using conduit tube,
and Completely seal the end of conduit tube
with sealing materials.

5
Power MCA
Source EN60 335-1 *1 EN60 335-1 *1
17-18 0.75A
22-24 220-240V 1.00A
27 50Hz 1.00A 2.5mm 2 0.75mm2
30 220V 1.10A
38 60Hz 1.98A
48 2.25A

The wire sizes marked with *1 in the above table are selected
Ex.) Set at No.16 Unit
at the maximum current of the unit according to the European Set by inserting
Setting DSW6
Standard, EN60335-1.Use the wires which are not lighter than Position Slotted screwdriver
into the groove
the ordinary polyvinyl chloride sheathed flexible cord
(code designation H05VV-F).
Set No.1 Pin ON
3 Before shipment. DSW6 and RSW1 are set to "0".
RSW1
Max.64 units are available to set when all the equipment
to be connected are corresponding to Hi-net.
Max.16 units when the units corresponding/
non-corresponding to Hi-net are combined. Set at "6"

Current(A) Wire Size(mm2 )


I≤3 2.5
3<l≤ 6 2.5 the indoor unit.
6<l≤10 2.5
10<I≤16 4
16<l≤25 6
25<l≤32 10
32<l≤50 16
50<l≤63 25
63<l Ć1

Ć1 In the case that current exceeds 63A, do not


connect cables inseries.

164
Capacity
× 103 Btu/h 17 18 22 24 27 30

Capacity
48
outlet air angle
3
× 10 Btu/h 38

Ex.) Set at No.5 Cycle


Outlet air angle
Setting Set by inserting DSW5
Position Slotted screwdriver
into the groove

Set All Pins OFF


Before shipment. DSW5 and RSW2 are set to "0".
RSW2
Max.64 cycles are available to set when all the equipment
to be connected are corresponding to Hi-net.
Max.16 cycles when the units corresponding/
non-corresponding to Hi-net are combined. Set at "5"

9.17

9.17.1

9.16

Open the air inlet grille after removing screw


covers and fixing screws.

clips

165
screw covers Screw 9.18.1
and fixing screws

Pull screw cover

9.18.2

Pull screw 9.18.3


cover

Fig.9.17.2 Open the air inlet grille

.9.17.2

9.18.4

9.17.3

9.18

166
10. Wall Mounted Type
10.1 General Data
Indoor Unit Type Wall Mounted Type
Model AC 1 , 220-240V/50Hz AVS-07URCSAB(A/B) AVS-09URCSAB(A/B) AVS-12URCSAB(A/B) AVS-14URCSAB(A/B) AVS-17URCSAB(A/B)
Power Supply AC 1 , 220V/60Hz AVS-07UR2SAB(A/B) AVS-09UR2SAB(A/B) AVS-12UR2SAB(A/B) AVS-14UR2SAB(A/B) AVS-17UR2SAB(A/B)
Nominal Cooling kW 2.3 2.9 3.8 4.2 5.2
Capacity *1) kcal/h 2,000 2,500 3,300 3,600 4,500
Btu/h 7,800 9,900 13,300 14,400 17,700
Nominal Cooling kW 2.2 2.8 3.6 4.0 5.0
Capacity *2) kcal/h 1,900 2,400 3,100 3,400 4,300
Btu/h 7,500 9,600 12,300 13,700 17,100
Cooling Power Consumption
(50Hz/60Hz) kW 0.50/0.55 0.50/0.55 0.60/0.65 0.60/0.65 0.65/0.75
Nominal Heating kW 2.5 3.3 4.0 4.5 5.6
Capacity kcal/h 2,150 2,800 3,400 3,900 4,800
Btu/h 8,500 11,300 13,700 15,300 19,100

Heating Power Consumption 0.60/0.65 0.60/0.65 0.65/0.75


0.50/0.55 0.50/0.55
(50Hz/60Hz) kW
Sound Pressure Level
39-34-32-28 39-34-32-28 43-39-32-28 43-39-32-28 45-40-34-29
(Overall A Scale) dB
Cabinet Color — White
Outer Dimensions
Height mm 315 315 315 315 315
(in.) (12-2/5) (12-2/5) (12-2/5) (12-2/5) (12-2/5)
Width mm 960 960 960 960 960
(in.) (37-4/5) (37-4/5) (37-4/5) (37-4/5) (37-4/5)
Depth mm 230 230 230 230 230
(in.) (9) (9) (9) (9) (9)
Net Weight kg 13.5 13.5 13.5 13.5 13.5
(lbs.) (17) (17) (17) (17) (17)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
660/590/520/460 660/590/520/460 830/660/520/460 830/660/520/460 900/750/590/460
Air Flow Rate m3/h
(388/347/306/271) (388/347/306/271) (488/388/306/271) (488/388/306/271) (529/441/347/271)
(Hi/Me/Lo) (cfm)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm 6.35 6.35 6.35 6.35 6.35
(in.) (1/4) (1/4) (1/4) (1/4) (1/4)
Gas Line mm 12.7 12.7 12.7 12.7 12.7
(in.) (1/2) (1/2) (1/2) (1/2) (1/2)
Condensate Drain — VP16 VP16 VP16 VP16 VP16
Approximate
Packing Measurement m3 0.17 0.17 0.17 0.17 0.17
Standard Accessories — Wall Mounting Bracket

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1 meter beneath the unit and 1 meter from inlet grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

167
Indoor Unit Type Wall Mounted Type
Model AC 1 , 220-240V/50Hz AVS-18URCSBB(A/B) AVS-22URCSBB(A/B) AVS-24URCSBB(A/B)
Power Supply AC 1 , 220V/60Hz AVS-18UR2SBB(A/B) AVS-22UR2SBB(A/B) AVS-24UR2SBB(A/B)
Nominal Cooling kW 5.8 6.5 7.3
Capacity *1) kcal/h 5,000 5,600 6,300
Btu/h 19,800 22,200 24,900
Nominal Cooling kW 5.6 6.3 7.1
Capacity *2) kcal/h 4,800 5,400 6,100
Btu/h 19,100 21,500 24,200
Cooling Power Consumption
(50Hz/60Hz) kW 0.54/0.65 0.62/0.74 0.72/0.83
Nominal Heating kW 6.3 7.1 8.0
Capacity kcal/h 5,400 6,100 6,900
Btu/h 21,500 24,200 27,300
Heating Power Consumption
(50Hz/60Hz) 0.62/0.75 0.72/0.83 0.82/0.91
kW
Sound Pressure Level
41-37-34-30 44-41-36-31 46-43-38-33
(Overall A Scale) dB
Cabinet Color — White
Outer Dimensions
Height mm 315 315 315
(in.) (12-2/5) (12-2/5) (12-2/5)
Width mm 1120 1120 1120
(in.) (44) (44) (44)
Depth mm 230 230 230
(in.) (9) (9) (9)
Net Weight kg 16.0 16.0 16.0
(lbs.) (20) (20) (20)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
893/782/671/582 1006/893/716/621 1122/984/804/649
Air Flow Rate m3/h
525/460/395/342) (592/525/421/365) (660/579/473/382)
(Hi/Me/ Lo /SLo) (cfm)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm 9.53 9.53 9.53
(in.) (3/8) (3/8) (3/8)
Gas Line mm 15.88 15.88 15.88
(in.) (5/8) (5/8) 5/8)
Condensate Drain — VP16 VP16 VP16
Approximate
Packing Measurement m3 0.19 0.19 0.19
Standard Accessories — Wall Mounting Bracket

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1 meter beneath the unit and 1 meter from inlet grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

168
10.2 Dimensional Data
Models:AVS-07~17*

Unit: mm

169
Models:AVS-18~24* Unit: mm

170
10.3 Selection Data
● Service Space
Models:AVS-07~24*

150 (unit:mm)

100 100

1000
Operation and Maintenance Space

● Sensible Heat Factor (SHF)


The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.

SHF
Indoor Unit Model
Hi Me Lo
AVS-07* 0.78 0.74 0.71
AVS-09* 0.78 0.74 0.71
AVS-12* 0.73 0.72 0.70
AVS-14* 0.73 0.72 0.70
AVS-17* 0.69 0.68 0.67
AVS-18* 0.69 0.68 0.67
AVS-22* 0.71 0.69 0.68
AVS-24* 0.73 0.71 0.69

171
● Sound Data
Model: AVS-07* Power Supply: 220~240V/50Hz,220V/60Hz Model: AVS-09* Power Supply: 220~240V/50Hz,220V/60Hz
Measurement Point: 1 Meter Beneath the Unit and Measurement Point: 1 Meter Beneath the Unit and
1 Meter From Discharge Grille 1 Meter From Discharge Grille
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Hi Hi

Me Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise SLo Continuous Noise SLo

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVS-12* Power Supply: 220~240V/50Hz,220V/60Hz Model: AVS-14* Power Supply: 220~240V/50Hz,220V/60Hz
Measurement Point: 1 Meter Beneath the Unit and Measurement Point: 1 Meter Beneath the Unit and
1 Meter From Discharge Grille 1 Meter From Discharge Grille
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

Hi Hi

Me Me

Lo Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise SLo Continuous Noise SLo

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

172
Model: AVS-17* Power Supply: 220~240V/50Hz,220V/60Hz Model: AVS-18* Power Supply: 220~240V/50Hz,220V/60Hz
Measurement Point: 1 Meter Beneath the Unit and Measurement Point: 1 Meter Beneath the Unit and
1 Meter From Discharge Grille 1 Meter From Discharge Grille
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Hi

Me
Hi

Me

Lo
Lo

Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise SLo
SLo

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVS-22* Power Supply: 220~240V/50Hz,220V/60Hz Model: AVS-24* Power Supply: 220~240V/50Hz,220V/60Hz
Measurement Point: 1 Meter Beneath the Unit and Measurement Point: 1 Meter Beneath the Unit and
1 Meter From Discharge Grille 1 Meter From Discharge Grille
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

Hi

Hi
Me
Me

Lo

Lo

Approximate SLo Approximate SLo


Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

173
● Temperature Data
AVS-07URCSAB(A/B)
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2.0 2.0
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
21
26
2m 40 2m
20
12

1m 1m

19 28
32 30
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

AVS-09URCSAB(A/B)
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2.0 2.0
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
21
26
2m 40 2m
20
12

1m 1m

19 28
32 30
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

174
AVS-12URCSAB(A/B)

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2.5 2.5
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
21
26
12
2m 40 2m
20

1m 1m

19 28
32 30
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

AVS-14URCSAB(A/B)

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2.5 2.5
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
21
26
12
2m 40 2m
20

1m 1m

19 28
32 30
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

175
AVS-17URCSAB(A/B)

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

3.0 3.0
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
20
26
12 40
2m 2m

19

1m 1m

18 28
32 30
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

AVS-18URCSAB(A/B)

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2.3 2.3
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
20
26
12 40
2m 2m
28
19

1m 1m

18 30
32
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

176
AVS-22URCSAB(A/B)

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2.5 2.5
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
20
26
12
2m 40 2m
19 28

1m 1m

18
32 30
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

AVS-24URCSAB(A/B)

Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2.5 3.0
2m 2m

1m 1m
0.8

0.5 0.3 0.8 0.5 0.3


0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

Temperature [°C] Temperature [°C]


2.7m 2.7m
20 26
12 19
2m 40 28 2m

1m 1m

19
32 30
0m 0m
0m 1.5m 3m 4.5m 6m 0m 1.5m 3m 4.5m 6m

177
10.4 Component Data

Indoor Heat Exchanger and Fan


Model AVS-07UR*BA(B) AVS-09UR*BA(B) AVS-12UR*BA(B) AVS-14UR*BA(B) AVS-17UR*BA(B)
Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows - 2 2 2 2 2
Fin Material Aluminum
Pitch mm 1.65 1.65 1.65 1.65 1.65
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 0.24 0.24 0.24 0.24 0.24
Number of Coil/Unit - 1 1 1 1 1
Indoor Fan Tubular Fan
Number/Unit - 1 1 1 1 1
Outer Diameter mm 107 107 107 107 107
Revolution (220V) rpm 1000/900/800/700 1000/900/800/700 1160/1000/800/700 1160/1000/800/700 1240/1060/900/700
Nominal Air Flow m3/h 660/590/520/460 660/590/520/460 830/660/520/460 830/660/520/460 900/750/590/460
Indoor Fan Motor Drip-Proof Type Enclosure PSC
-
Starting Method (Permanent Split Capacitor)
Nominal Output W 35 35 35 35 35
Quantity 1 1 1 1 1
Insulation Class
- E E E E E

Indoor Heat Exchanger and Fan

Model AVS--18URC* AVS--22URC* AVS--24URC*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0
Rows - 2 2 2
Fin Material Aluminum
Pitch mm 1.65 1.65 1.65
Maximum Operating Pressure MPa 4.15 4.15 4.15
Total Face Area m2 0.33 0.33 0.33
Number of Coil/Unit - 1 1 1
Indoor Fan Tubular Fan
Number/Unit - 1 1 1
Outer Diameter mm 100 100 100
Revolution (220V) rpm 1000/910/820/750 1100/1000/840/750 1200/1080/920/780
Nominal Air Flow m /h3
893/782/671/582 1006/893/716/621 1122/984/804/649
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 50 50 50
Quantity - 1 1 1
Insulation Class - E E E

178
Indoor Heat Exchanger and Fan

Model AVS--18UR2* AVS--22UR2* AVS--24UR2*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0
Rows - 2 2 2
Fin Material Aluminum
Pitch mm 1.65 1.65 1.65
Maximum Operating Pressure MPa 4.15 4.15 4.15
Total Face Area m2 0.33 0.33 0.33
Number of Coil/Unit - 1 1 1
Indoor Fan Tubular Fan
Number/Unit - 1 1 1
Outer Diameter mm 100 100 100
Revolution (220V) rpm 1000/910/820/750 1100/1000/840/750 1200/1080/920/780
Nominal Air Flow m /h
3
893/782/671/582 1006/893/716/621 1122/984/804/649
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 50 50 50
Quantity - 1 1 1
Insulation Class - E E E

Indoor Heat Exchanger and Fan

179
10.5 Refrigeration Cycle

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

4 b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

180
10.6 Electrical Data

< 50 Hz >
Indoor Unit

Unit Main Power Applicable Voltage Indoor Fan Motor


Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVS-07URCSAB(A/B) 0.4 0.05
Wall Mounted
AVS-09URCSAB(A/B) 0.4 0.05
Type
AVS-12URCSAB(A/B) 0.45 0.06
AVS-14URCSAB(A/B) 0.45 0.06
220~240 1 50 264 198 1
AVS-17URCSAB(A/B) 0.5 0.065
AVS-18URCSBB(A/B) 0.41 0.062
AVS-22URCSBB(A/B) 0.41 0.072
AVS-24URCSBB(A/B) 0.41 0.082

< 60 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVS-07UR2SAB(A/B) 0.4 0.05
Wall Mounted
AVS-09UR2SAB(A/B) 0.4 0.05
Type
AVS-12UR2SAB(A/B) 0.45 0.06
AVS-14UR2SAB(A/B) 0.45 0.06
220 1 60 264 198 1
AVS-17UR2SAB(A/B) 0.5 0.065
AVS-18UR2SBB(A/B) 0.41 0.062
AVS-22UR2SBB(A/B) 0.41 0.072
AVS-24UR2SBB(A/B) 0.41 0.082

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

Safety and Control Device Setting

Model AVS-07~24*

For Evaporator Fan


Motor Thermostat ℃ 130±5
Cut-Out
Cut-In ℃ 83±15
For Control Circuit
Fuse Capacity A 5
Freeze Protection
Thermostat ℃ 0
Cut-Out
Cut-In ℃ 14

Thermostat
℃ 2
Differential

181
10.7 Electrical Wiring Diagram
Model: AVS-09~24*

182
10.8 Indoor Unit Optional Parts
Optional Parts Applied Indoor Unit Type

Type Model Wall Mounted Type

HYXE-F01H ●
HYXE-G01H ●
Wire Remote Control Switch HYXE-A01H#01 ●
HYXE-J01H ●
HYXE-M01H ●
Wireless Remote Control Switch HYE-L01 ●
HYE-W01 ● Standard Option
HYRE-V01H
HYRE-T01H
Wireless Receiver Kit
HYRE-V02H
HYRE-X01H
7 Day Timer HYDE-E01H ●
HYJE-H01H ●
HYJE-D02H ●
HYJ-J01H ●
Centrol Station HCCS-H128H2C1YM ●
HCCS-H128H2C1NM
HCCS-H247R4C1E
HCCS-H128H2C2NM ●
HC-A64BNP ●
Interface for Building Control
HCPC-H2M1C ●
HPS-162#E
Drain Pump HPS-132#E
HPS-151#E
HF-224L-FE
Long Life filter HF-280L-FE
HF-40L-ZFE
HP-DB-NK
3D Air Swing
HP-EB-NK

183
10.9

10.10 Installation
10.10.1

184
10.10.2

below.

185
186
10.10.3 10.10.4

187
10.11

10.11.1
10.10

188
10.11.2

below.

189
10.12
below.

below.

below.

190
10.13

191
10.13.1

10.13.2

Wiring Connection).

192
10.15
10.15.1

10.14

220V~60Hz

193
Current(A) Wire Size(mm2 )
I≤3 2.5
3<l≤ 6 2.5
6<l≤10 2.5
10<I≤16 4
16<l≤25 6
25<l≤32 10
32<l≤50 16
50<l≤63 25
63<l Ć1

Ć1 In the case that current exceeds 63A, do not


connect cables inseries.

10.15.2

194
10.15.3

195
10.15.4

196
197
10.16 10.17

198
10.18 10.19

10.18.1

10.19.1

10.19.2

10.19.3

10.18.2
10.19.4

10.18.3

199
11. Floor Concealed Type(AVH)
11.1 General Data
Indoor Unit Type Floor Concealed Type
Model AC 1 , 220-240V/50Hz AVH-09UXCSAA AVH-14UXCSAA AVH-18UXCSBA AVH-24UXCSBA
Power Supply AC 1 , 220V/60Hz AVH-09UX2SAA AVH-14UX2SAA AVH-18UX2SBA AVH-24UX2SBA
Nominal Cooling kW 2.9 4.1 5.8 7.3
Capacity *1) kcal/h 2,500 3,500 5,000 6,300
Btu/h 9,900 14,000 19,800 24,900
Nominal Cooling kW 2.8 4.3 5.6 7.1
Capacity *2) kcal/h 2,400 3,700 4,800 6,100
Btu/h 9,600 14,700 19,100 24,200

Cooling Power Consumption kW 0.05 0.08 0.09 0.12


Nominal Heating kW 3.3 4.9 6.5 8.5
Capacity kcal/h 2,800 4,200 5,600 7,300
Btu/h 11,300 16,700 22,200 29,000

Heating Power Consumption kW 0.05 0.08 0.09 0.12


Sound Pressure Level
(Overall A Scale) dB 34-31-27 40-36-34 41-36-32 44-40-36
Cabinet Color — --
Outer Dimensions
Height mm 620 620 620 620
(in.) (24-7/16) (24-7/16) (24-7/16) (24-7/16)
Width mm 900 900 1170 1170
(in.) (35-2/5) (35-2/5) (46) (46)
Depth mm 202 202 202 202
(in.) (8) (8) (8) (8)
Net Weight kg 18 22 26 27
(lbs.) (40) (48) (57) (59)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 510/450/380 620/540/480 890/740/630 980/830/710
(Hi/Me/Lo) (cfm) (300/265/223) (365/318/282) (523/435/370) (576/488/417)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm 6.35 6.35 6.35 9.53
(in.) (1/4) (1/4) (1/4) (3/8)
Gas Line mm 12.7 12.7 15.88 15.88
(in.) (1/2) (1/2) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.19 0.19 0.23 0.23
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
*1) 19.5oC WB (67oF WB)
*2) 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1 meter beneath the unit and 1 meter from inlet grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

200
11.2 Dimensional Data
Models: AVH-09~24*

Refrigerant Gas Line


09 and 14 Model: φ 12.7 with Flare Nut
18 and 24 Model: φ 15.88 with Flare Nut

Air Outlet Refrigerant Liquid Line


09 and 18 Model: φ 6.35 with Flare Nut
24 Model: φ 9.53 with Flare Nut

202
a
168

61 72 109
b
Connection Flange 113
c
33
619

397
394
258
157

Fan Motor
Fan
Return Air Inlet
25 d 39 120

99

99
194
120

e f
b b

Fixing Hole on Floor

Screw Hole (2-M10)

(4-M6)

Unit
Dimension
Model
AVH-09*
AVH-14*
AVH-18*
AVH-24*

201
11.3 Selection Data
● Service Space
Models: AVH-09~24*

Ceiling Ceiling

Upward Air Outlet


Short

1000
Front Air Outlet

Min.
Flexible Duct

620
640
Floor Floor
Min. Min. Min. Min.
240 240 240 240

Service Space
● Sensible Heat Factor (SHF)
The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.

SHF
Indoor Unit Model
Hi Me Lo
AVH-09* 0.81 0.69 0.68
AVH-14* 0.75 0.71 0.67
AVH-18* 0.70 0.70 0.67
AVH-24* 0.68 0.68 0.66

202
● Sound Data

Model: AVH-09* Power Supply: 220~240V/50Hz,220V/60Hz Model: AVH-14* Power Supply: 220~240V/50Hz,220V/60Hz
Measurement Point: 1.5 Meter from the Unit Measurement Point: 1.5 Meter from the Unit
1.5 Meter from Floor Level 1.5 Meter from Floor Level
Noise Criteria Curve Noise Criteria Curve

80 80
Octave Sound Pressure Level (dB: Overall C Scale)

Octave Sound Pressure Level (dB: Overall C Scale)


70 70

60
60

50 50

40 40

30 30

20 20
Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Central Frequency (Cycle per Second) Central Frequency (Cycle per Second)

Model: AVH-18* Power Supply: 220~240V/50Hz,220V/60Hz Model: AVH-24* Power Supply: 220~240V/50Hz,220V/60Hz
Measurement Point: 1.5 Meter from the Unit Measurement Point: 1.5 Meter from the Unit
1.5 Meter from Floor Level 1.5 Meter from Floor Level
Noise Criteria Curve Noise Criteria Curve

80 80
Octave Sound Pressure Level (dB: Overall C Scale)

Octave Sound Pressure Level (dB: Overall C Scale)

70 70

60
60

50 50

40 40

30 30

20 20
Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Central Frequency (Cycle per Second) Central Frequency (Cycle per Second)

203
11.4 Component Data
Indoor Heat Exchanger and Fan

Model AVH--09* AVH--14* AVH--18* AVH--24*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 2 3 3 3
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.13 0.13 0.18 0.18
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1 1
Outer Diameter mm 130 130 130 130
Revolution (220V) rpm 475/420/340 585/485/440 630/515/450 640/525/460
Nominal Air Flow m /h
3
510/450/380 620/540/480 890/740/630 980/830/710
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 20 35 40 50
Quantity - 1 1 1 1
Insulation Class - B B B B

204
11.5 Refrigeration Cycle

Floor Concealed Type

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

205
11.6 Electrical Data
< 50 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVH-09UXCSAA 0.25 0.05
Floor
AVH-14UXCSAA 0.40 0.08
Concealed 220~240 1 50 264 198 1
AVH-18UXCSBA 0.43 0.09
Type
AVH-24UXCSBA 0.55 0.12

< 60 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVH-09UX2SAA 0.25 0.05
Floor AVH-14UX2SAA 0.40 0.08
220 1 60 242 198 1
Concealed Type AVH-18UX2SBA 0.43 0.09
AVH-24UX2SBA 0.55 0.11

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

09~24

206
Model: AVH-09~24*
11.7 Electrical Wiring Diagram

207
11.8 Indoor Unit Optional Parts

Optional Parts Applied Indoor Unit Type

Type Model Floor Concealed Type

HYXE-F01H ●
HYXE-G01H ●
Wire Remote Control Switch HYXE-A01H#01 ●
HYXE-J01H ●
HYXE-M01H ●
HYE-L01 ●
Wireless Remote Control Switch
HYE-W01 ●
HYRE-V01H ●
HYRE-T01H
Wireless Receiver Kit
HYRE-V02H
HYRE-X01H
7 Day Timer HYDE-E01H ●
HYJE-H01H ●
HYJE-D02H ●
HYJ-J01H ●
Centrol Station HCCS-H128H2C1YM ●
HCCS-H128H2C1NM
HCCS-H247R4C1E
HCCS-H128H2C2NM ●
HC-A64BNP ●
Interface for Building Control
HCPC-H2M1C ●
HPS-162#E
Drain Pump HPS-132#E
HPS-151#E
HF-224L-FE
Long Life filter HF-280L-FE
HF-40L-ZFE
HP-DB-NK
3D Air Swing
HP-EB-NK

208
11.9

209
11.11
11.10 Installation Check
11.11.1

Ceiling

Outlet

At least 1000
619
At least 250 At least 250

Wall

At least 800
At least 50 (Maintenance space)

Size

09~14

18~24

Fig. Suspension Bolts

210
11.11.2 Hanging the IndoorUnit 11.11.3 Connecting Supply Duct
Prevent the subversion of the machine. The supply duct should be inserted onto the root of
The method for ground installation is shown below. the unit outlet. Thermal insulation should be done
Fix the unit with bolt in the specified location as and the junction with the unit should be sealed
shown below. with aluminum foil tape.
Insulation materials should be attached all around
the outlet preventing the condensation, when there
is no duct connected.
Bolt adjustment hole Anchor bolt fixed position Duct

Insulation materials
Tape Outlet

Size Insulation materials Outlet


Attached all around
09~14 (At least 10mm)

18~24

11.12

Nut
Anchor M10
Washer 1 A
Concrete
Filling Motar

Fig. Installation Method

11.12.1

211
11.12.2
below.

202
168
72 109 58

113 50
33

Gas pipe
Liquid pipe
394

Water tray
397
258

below.

09~14

18

24

Flaring Dimension
Perform the flaring work as shown below.

ΦD
Φa
R 410A R 407C
6.35 9.1 9.0
9.53 13.2 13.0
12.7 16.6 16.2
15.88 19.7 19.4
19.05 ( * ) 23.3

installation
(*)It is impossible to perform the flaring work with
1/2H material. In this case, use an accessory
pipe(with a flare).

212
11.13

below.

11.14

213
11.14.1

11.14.2

below.
As below
220-240V~ 50Hz
220V~60Hz

11.15

214
Current(A) Wire Size(mm2 )
I≤3 2.5
3<l≤ 6 2.5
6<l≤10 2.5
10<I≤16 4
16<l≤25 6
25<l≤32 10
32<l≤50 16
50<l≤63 25
63<l Ć1

Ć1 In the case that current exceeds 63A, do not


connect cables inseries.

11.16 11.16.2

11.16.1

Use an ELB (Electric Leakage Breaker).If not


used ,it will cause an electric shock or a fire.
Run through the cables using conduit tube,
and Completely seal the end of conduit tube
with sealing materials.

5
Model MCA EN 60335-1 EN 60335-1
1 1

09 0.46A

14 0.56A
2.5 0.75 a
18 0.70A

24 0.83A

Ex.) Set at No.16 Unit


Setting Set by inserting DSW6
The wire sizes marked with *1 in the above table are selected Position Slotted screwdriver
into the groove
at the maximum current of the unit according to the European
Standard, EN 60335-1.Use the wires which are not lighter than
Set No.1 Pin ON
the ordinary polyvinyl chloride sheathed flexible cord Before shipment. DSW6 and RSW1 are set to "0".
(code designation H05VV-F). RSW1
Max.64 units are available to set when all the equipment
to be connected are corresponding to Hi-NET.
3 Max.16 units when the units corresponding/
non-corresponding to Hi-NET are combined. Set at "6"

215
Capacity 09 14 18 24

11.16.3 FILTER SIGN RESET

Ex.) Set at No.5 Cycle


Setting Set by inserting DSW5
Position Slotted screwdriver
into the groove

Set All Pins OFF


Before shipment. DSW5 and RSW2 are set to "0".
RSW2
Max.64 cycles are available to set when all the equipment
to be connected are corresponding to Hi-NET.
Max.16 cycles when the units corresponding/
non-corresponding to Hi-NET are combined. Set at "5"

11.17 Troubleshooting

11.17.1

216
11.17.2

11.17.3

11.17.4

217
12. All Fresh Air Indoor Unit(AVA)
12.1 General Data
Indoor Unit Type All Fresh Air Indoor Unit
Model AC 1 , 220-240V/50Hz AVA-30UXCSCH-70 AVA-48UXCSQH-108 AVA-76UXCSRH-168 AVA-96UXCSRH-210
Power Supply AC 1 , 220V/60Hz AVA-30UX2SCH-70 AVA-48UX2SQH-108 AVA-76UX2SRH-168 AVA-96UX2SRH-210
Nominal Cooling kW 9.0 14.0 22.4 28.0
Capacity kcal/h 7,700 12,000 19,300 24,100
Btu/h 30,700 47,800 76,500 95,600

Cooling Power Consumption kW 0.15 0.33 0.49 0.51


Nominal Heating kW 8.6 13.7 21.9 24.5
Capacity kcal/h 7,400 11,800 18,800 21,100
Btu/h 29,400 46,800 74,700 83,600

Heating Power Consumption kW 0.15 0.33 0.49 0.51


Sound Pressure Level
(Overall A Scale) dB 32 43 45 46
Outer Dimensions
Height mm 370 370 486 486
(in.) (14-1/2) (14-1/2) (19-1/7) (19-1/7)
Width mm 920 1,320 1,270 1,270
(in.) (36-1/5) (52) (50) (50)
Depth mm 800 800 1,069 1,069
(in.) (31-1/2) (31-1/2) (42) (42)
Net Weight kg 46 60 97 97
(lbs.) (101) (132) (213) (213)
Refrigerant — R410A(Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 660 1080 1680 2100
(Hi/Me/Lo) (cfm) (388) (635) (988) (1235)
External Pressure Pa 60(120) 200 220 220

Connections Flare-Nut Connection (with Flare Nuts) Brazing


Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53
(in.) (3/8) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ19.05 Φ22.2
(in.) (5/8) (5/8) (3/4) (7/8)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.38 0.52 1.09 1.09
NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Outdoor Air Inlet Temperature: 33oC DB 28oC WB
Heating Operation Conditions
Outdoor Air Inlet Temperature: 0 oC DB -2.9oC WB
Piping Length: 7.5 Meters Piping Lift: 0 Meter
(Heating capacity is tested when defrosting is not available)
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. An air filter with dust collection efficiency more than 50% needs to be attached to the duct system of the suction side at site.
4. When the resistance of the field-supplied duct is small, it may cause abnormal stoppage, malfunction, spraying water, etc. due to excessive air flow.
And the duct, which is to be connected to this unit, shall be insulated for dew protection.
5. All fresh air indoor unit is for processing fresh air load and not for stabilizing the room temperaure. For adjusting the air conditioning load of the room,
the additional air conditioner is required.
6. This unit shall be connected to Hi-Flexi outdoor unit. In case of connecting this unit with other indoor units in the same refrigerant cycle, calculate the
capacity of this unit as 13.5kW(3HP), 21.0kW(5HP), 33.6kW(8HP), 42.0kW(10HP).
7. When outdoor unit is connected only with all fresh air indoor unit, the configuration rate is 100%.
8. Under cooling mode, when outdoor temperature is lower than 20 ℃, the system will automatically shift to ventilation operation;
Under heating mode, when outdoor temperature is higher than 15℃, the system will automatically shift to ventilation operation;
In case inlet temperature is below -5℃, All Fresh Air Indoor Unit will stop.

218
Indoor Unit Type All Fresh Air Indoor Unit
Model AC 3 , 380-415V/50Hz AVA-114UX6SRH-300 AVA-154UX6SSH-400 AVA-190UX6STH-500 AVA-190UX6STH-600
Power Supply AC 3 , 380V/60Hz AVA-114UX7SRH-300 AVA-154UX7SSH-400 AVA-190UX7STH-500 AVA-190UX7STH-600
Nominal Cooling kW 33.5 45.0 56.0 56.0
Capacity kcal/h 28,800 38,700 48,200 48,200
Btu/h 114,300 153,600 191,100 191,100

Cooling Power Consumption kW 0.74 1.12 1.33 1.62


Nominal Heating kW 26.8 36.0 44.8 44.8
Capacity kcal/h 23,000 31,000 38,500 38,500
Btu/h 91,500 122,900 152,900 152,900

Heating Power Consumption kW 0.74 1.12 1.33 1.62


Sound Pressure Level
(Overall A Scale) dB 56 61 64 66
Outer Dimensions
Height mm 486 635 735 735
(in.) (19-1/7) (25) (29) (29)
Width mm 1,270 1,950 1,950 1,950
(in.) (50) (76-4/5) (76-4/5) (76-4/5)
Depth mm 1,069 805 805 805
(in.) (42) (31-7/10) (31-7/10) (31-7/10)
Net Weight kg 97 196 222 222
(lbs.) (213) (431) (488) (488)
Refrigerant — R410A(Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 3000 4000 5000 6000
(Hi/Me/Lo) (cfm) (1764) (635) (2940) (3528)
External Pressure Pa 220 300 300 300

Connections Brazing
Refrigerant Piping
Liquid Line mm Φ12.7 Φ12.7 Φ15.88 Φ15.88
(in.) (1/2) (1/2) (5/8) (5/8)
Gas Line mm Φ25.4 Φ25.4 Φ28.6 Φ28.6
(in.) (1) (1) (1-1/8) (1-1/8)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 1.09 1.84 2.06 2.06
NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Outdoor Air Inlet Temperature: 33oC DB 28oC WB
Heating Operation Conditions
Outdoor Air Inlet Temperature: 0 oC DB -2.9oC WB
Piping Length: 7.5 Meters Piping Lift: 0 Meter
(Heating capacity is tested when defrosting is not available)
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. An air filter with dust collection efficiency more than 50% needs to be attached to the duct system of the suction side at site.
4. When the resistance of the field-supplied duct is small, it may cause abnormal stoppage, malfunction, spraying water, etc. due to excessive air flow.
And the duct, which is to be connected to this unit, shall be insulated for dew protection.
5. All fresh air indoor unit is for processing fresh air load and not for stabilizing the room temperaure. For adjusting the air conditioning load of the room,
the additional air conditioner is required.
6. All fresh air indoor unit (12HP~20HP) only can be connected with Hi-Flexi outdoor unit one to one.
7. Under cooling mode, when outdoor temperature is lower than 20 ℃, the system will automatically shift to ventilation operation;
Under heating mode, when outdoor temperature is higher than 15℃, the system will automatically shift to ventilation operation;
In case inlet temperature is below -5℃, All Fresh Air Indoor Unit will stop.

219
12.2 Dimensional Data
Models: AVA-30~48*

1320(920)
1380(980)

1203(803) 1233(833)

NOTE: Data in bracket is for Model: AVA-30*

Models: AVA-76~114*

220
Models: AVA-154~190*

AVA-154
AVA-190

221
12.3 Selection Data
● Service Space
Models: AVA-30~190*

● Sensible Heat Factor (SHF)


The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.

SHF
Indoor Unit Model
Hi Me Lo
AVA-30* 0.43 ─ ─
AVA-48* 0.42 ─ ─
AVA-76* 0.41 ─ ─
AVA-96* 0.40 ─ ─
AVA-114* 0.40 ─ ─
AVA-154* 0.42 ─ ─
AVA-190*-500 0.41 ─ ─
AVA-190*-600 0.41 ─ ─

222
● Fan Performance

AVA-30UXCSCH-70(60Pa)

100

80

60

40

20
585 693.6 844.3

AVA-30UXCSCH-70(120Pa)

160

140

120

100

80
518 656.4 771

AVA-48UXCSQH-108

223
AVA-76UXCSRH-168

AVA-96UXCSRH-210

AVA-114UX6SRH-300

224
AVA-154UX6SSH-400

AVA-190UX6STH-500

AVA-190UX6STH-600

225
● Sound Data

Model: AVA-30* Power Supply: 220~240V/50Hz,220V~60Hz Model:AVA-48* Power Supply: 220~240V/50Hz,220V~60Hz


Measurement Point: 1.5 Meters Beneath the Unit

Noise Criteria Curve Noise Criteria Curve


Octave Sound Pressure Level(dB: Overall C Scale)

Approximate
Threshold of
Hearing for
Continuous Noise

Central Frequency(Cycle per Second)

Model:AVA-76* Power Supply: 220~240V/50Hz,220V~60Hz Model:AVA-96* Power Supply: 220~240V/50Hz,220V~60Hz

226
Model: AVA-114* Power Supply: 380V~415V 380V~60Hz Model: AVA-154* Power Supply: 380V~415V 380V~60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


Approximate Approximate
Threshold of Threshold of
Hearing for Hearing for
Continuous Noise Continuous Noise

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model: AVA-190-500* Power Supply: 380V~415V 380V~60Hz


Model: AVA-190-600* Power Supply: 380V~415V 380V~60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

Approximate
Threshold of Approximate
Hearing for Threshold of
Continuous Noise Hearing for
Continuous Noise

Central Frequency(Cycle per Second)


Central Frequency(Cycle per Second)

227
12.4 Component Data
Indoor Heat Exchanger and Fan

Model AVA-30* AVA-48* AVA-76* AVA-96*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 9.53 9.53
Rows - 2 3 3 3
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.294 0.46 0.56 0.62
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 2 2
Outer Diameter mm 200.4 200.4 227.4 227.4
Revolution (220V) rpm 800 1,310 1,220 1,270
Nominal Air Flow m3/h 660 1080 1,680 2,100
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 60 180 140 180
Quantity - 1 1 2 2
Insulation Class - F F F F

Model AVA-114* AVA-154* AVA-190*-500 AVA-190*-600


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 9.53 9.53 9.53 9.53
Rows - 3 3 3 3
Fin Material Aluminum
Pitch mm 1.8 1.8 1.8 1.8
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.62 0.94 1.11 1.11
Number of Coil/Unit - 1 1 1 1
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1 1
Outer Diameter mm 254.5 387 387 387
Revolution (380V) rpm 1,200 1,400 1,400 1,420
Nominal Air Flow m3/h 3,000 4,000 5,000 6,000
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 600 1100 1500 2200
Quantity - 1 1 1 1
Insulation Class - F F F F

228
12.5 Refrigeration Cycle

AVA-30~114*

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

229
AVA-154~190*

Refrigerant Gas Pipe


Connection (A)

2
3
Refrigerant Liquid Pipe
Connection (B)

: Refrigerant Flow Direction (Cooling)


: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
: Brazing or Flare-nut Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

230
12.6 Electrical Data

Indoor Unit
< 50 Hz >
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVA-30UXCSCH-70 0.65 0.15
AVA-48UXCSQH-108 1.45 0.33
220~240 1 50 264 198 1
AVA-76UXCSRH-168 2.25 0.49
All Fresh Air AVA-96UXCSRH-210 2.35 0.51
Indoor Unit AVA-114UX6SRH-300 1.47 0.74
AVA-154UX6SSH-400 1.92 1.12
380~415 3 50 456 342 3
AVA-190UX6STH-500 2.45 1.33
AVA-190UX6STH-600 2.96 1.62

Indoor Unit
< 60 Hz >
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT
AVA-30UXCSCH-70 0.14 0.65
AVA-48UXCSQH-108 0.31 1.45
220 1 60 242 198 1
AVA-76UXCSRH-168 0.61 2.79
All Fresh Air AVA-96UXCSRH-210 0.71 3.25
Indoor Unit AVA-114UX6SRH-300 0.70 1.47
AVA-154UX6SSH-400 1.07 1.92
380 3 60 418 342 3
AVA-190UX6STH-500 1.27 2.45
AVA-190UX6STH-600 1.54 2.96

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

AVA-30~96* AVA-114~190*

130±5 145±5
83±15 80±15

5 5

0 0
14 14

2 2

231
12.7 Electrical Wiring Diagram
Model: AVA-30*

232
Electrical Wiring Diagram
Model: AVA-48*

233
Model: AVA-76~96*
Electrical Wiring Diagram

234
Electrical Wiring Diagram Model: AVA-114*

235
Electrical Wiring Diagram Model: AVA-154*~190*

236
12.8 Indoor Unit Optional Parts

Optional Parts Applied Indoor Unit Type

Type Model All Fresh Air Indoor Unit

HYXE-F01H ●
HYXE-G01H
Wire Remote Control Switch HYXE-A01H#01 ●
HYXE-J01H ●
HYXE-M01H ●
HYE-L01 ●
Wireless Remote Control Switch
HYE-W01 ●
HYRE-V01H ●
HYRE-T01H
Wireless Receiver Kit
HYRE-V02H
HYRE-X01H
7 Day Timer HYDE-E01H ●
HYJE-H01H ●
HYJE-D02H ●
HYJ-J01H ●
Centrol Station HCCS-H128H2C1YM ●
HCCS-H128H2C1NM
HCCS-H247R4C1E
HCCS-H128H2C2NM ●
HC-A64BNP ●
Interface for Building Control
HCPC-H2M1C ●
HPS-162#E
Drain Pump HPS-132#E
HPS-151#E
HF-224L-FE
Long Life filter HF-280L-FE
HF-40L-ZFE
HP-DB-NK
3D Air Swing
HP-EB-NK

237
12.9 Factory-Supplied Accessories

Model: AVA-30*~114*

2QO\IRU30~48N%WXK 5
2QO\IRU76~114N%WXK

2QO\IRU30~48N%WXK 5

2QO\IRU76~114N%WXK 6

M 1

2QO\IRU30~48N%WXK
M 16

238
12.10 Installation For Model(30~114)
12.10.1

below.
Model:30~48 unit:mm
Model:76~114

12.10.2

239
● Model:48 unit:mm

32
306
370
1233

30
22
unit:mm
Model:30

800
756
833

22
30
30 1320
1380

58 1203

220
110
(2)

unit:mm
Model:76~114
920
980 1100

34
803

415
486
21×50=1050

Φ3 26
(1)
1021
1069

Φ3
29

4-40×12 20×50=1000
1270
1288 40

1106
110
30
338

(3)

240

below.

below.

241
● ●

242
12.11 Refrigerant Piping Work For Model(30~114) Model:76~114 B-
unit:mm
C- A-

Air inlet Air Outlet

mm(in.)
MODEL A B C

12.11.1 30 15.88(5/8) 9.53(3/8)

48 15.88(5/8) 9.53(3/8)

19.05(3/4) 9.53(3/8) VP 25
76
96 22.2(7/8) 9.53(3/8)

114 25.4(1) 12.7(1/2)

12.11.2

An excess or a shortage of refrigerant is the


main cause of trouble to the units.
Charge the correct refrigerant quantity.

unit:mm
Model:30~48 A-Refrigerant Gas C-Drain Pipe
Pipe Connection Connection
B-Refrigerant Liquid
Pipe Connection
244
202

81

95

243
12.12 Drain Piping For Model(30~114)

below.

below.

244
12.13.1

12.13.2
12.13 Electrical Wiring For Model(30~114)
below.

Model:30~48

Air outlet
Air inlet

Electrical Box Cover


Model:76~114

245
Cord Clamp

Cord Clamp
Operating Wires Power Supply

Cable of Remote Cable of


Control Switch Cord Clamp Remote
Cord Clamp Control
Power Supply Switch

Power Supply Operating Wires


220-240V 220-240V
~ 50Hz
 ̄/50Hz
220V~/60Hz
)
Power Supply Model:76~96
Operating Cable of Remote
220-240V
Wires Control Switch ~ 50Hz

Wiring Connection TerminalBoard(TB)


Enlarged View of P

Model:30~48

Cord Clamp Cable of


Remote
Control
Switch
Power Supply
380-415V Operating Wires
3N~ 50Hz

Model:114

246
12.14 Common (For Model 30~114)
12.14.1

Use an ELB(Electric Leakage Breaker).If not used,


it will cause an electric shock or a fire.

Run through the cables using conduit tube,and


Completely seal the end of conduit tube with
sealing materials.

Model Power MCA


Source EN60335-1 EN60335-1
1 1

30 1.2A 0.75mm2
2.5mm 2

48 220- 240V 2.5A 2.5mm 2 0.75mm2


~ 50Hz
220V~60Hz
76 5.2A 2.5mm 2 0.75mm2

96 6.0A 2.5mm 2 0.75mm2

380-415V
3N~ 50Hz
114 2.7A 2.5mm 2 0.75mm2
380V~60Hz

12.15 Factory-Supplied Accessories(For Model 154~190)

Model: AVA-154*~190*

(In c lu d in g Tw o R em o te Tem p eratu re Sen s o rs)

247
12.16 Installation (For Model 154~190)
12.16.1

below.

unit:mm
800 or more

Working
Keep enough distance between the indoor unit and
Space
800 or more the walls around to avoid contacting each other
Air Inlet Piping
Surface of the ceiling

50 or more
Vent-pipe

Air Passage
50 or more

Air Strainer
500 or more

(Field Supply)
100

Electrical Box
Support Board
Service Access Panel (Field Supply)
(600)
500 or more

The indoor unit is not designed for the places that (B)Install the indoor unit and components as far as
need quiet environment .Install the indoor unit in practical or at least 3meters from the electromagnetic
the places like equipment rooms that do not bring wave radiator.
noise problems.
(C)Prepare a steel box and install the remote control
Avoid bostacles which m ay hamper the air intake switch in it.Prepare a steel conduit tube and wire
or the air discharge flow. the remote control cable in it.Then,connect the
Do not install the indoor unit in a machine shop or ground wire with the box and the tube.
kitchen where vapor from oil or its mist flows to (D) Install a noise filter when the power supply emits
the indoor unit. harmful noises.
The oil will deposit on the heat exchanger,
To avoid any corrosive action to the heat
thereby reducing the indoor unit
exchangers,do not install the indoor unit in an acid or
performance,and may deform and in the worst alkaline environment.
case,break the plasticparts of the indoor unit.
Install the service access panel at the same side with
Pay attention to the following points when the indoor the electrical box in order to maintain and service
unit is installed in a hospital or other facilities where
conveniently.
there are electronic waves from medical equipment.
( A)Do not i nstall the indoo r unit whe re the electromagetic The indoor unit can not control the tempreture.
wave is directly radiated to the electrical box,remote Do not install the indoor Unit in places like the plage or
control cable or remote control switch. hotspring where the environment is saliferous and
corrodent.

248
unit:mm

Air Inlet
12.16.2 1520
1520

● Suspension bolts
(1)Select final location and installation direction of the
indoor unit paying careful attention to the space for

A
the piping, wiring and maintenance.

B
(2)Using suspendion bolts to install the indoor
unit.Check the celing whether is strong enough
to support the indoor unit.Plase reinforce the
ceiling before installation if it is not safe.
160×9=1440
(3)Install the indoor unit 2.5 meters higher from 69
69
the floor level,when exposed outdoor.
(4)Strainer(Field Supply)must be installed in the Ø17
pipeline.Make sure the the outdoor air through
the strainer
805
530

200×4=800
1950
2090
Ceiling

Anchor Bolt Air Outlet


850
Long Nut or Thread Take-up

C
Suspension Bolts
270

Indoor Unit
550

Fig. Sling Bolts

● MODEL A B C

154 520 635 130


190 620 735 230

249
● Hanging Indoor Unit
Install the indoor unit and the support
board using bolts (M12)as shown below.
Adjust the indoor unit installed to the
preconcerted height.
Hook the suspendion bracket to the nut
and washer of rach hanging bolt.
Check to ensure the indoor unit is
horizontally.
If the indoor unit is not horizontal,it may
cause a leakage.
Adjust theangle of the indoor unit using the
gradienter or polyethylene pipe .
Screw down the nuts.
Tighten the bolts of the sling nuts with the
suspension brackets after Adjustment is
completed.
Special plastic paint must be applied to the
bolts in order to prevent them from
loosening.

Setscrew (M12)
(Field Supply) Nut (Field Supply)

Support Board
Polyethylene Pipe
Polyethylene Pipe (Field Supply)
Drain Pipe Sleeve
Washer (Field Supply)

Nut×2 (Field Supply)


Sling Bolt
Bolt: M12
Drain Pipe
Sleeve

A:0~14mm B 0~36mm Fig Hanging Methods

Fig Installation Methods

250
● 12.17 Refrigerant PipingWork
Connect the duct as follows. (For Model 154~190)
<Air Inlet>
Connect the duct with flange inlet
together.
Seal the pontes between the flange inlet
and duct using the aluminous adhesive
tape.
<Air Outlet>
Connect the duct with flange o utlet
together.
Seal the pontes between the flange
outletand duct using the aluminous
adhesive tape. 12.17.1
Connect the flange outlet with the
indoor unit together using screws.

Flange Inlet Flange Outlet


Thermal Insulation
The Wall Thermal Insulation
Outside
The Indoor
(Downward Slop) Unit Air Outlet
Canvas Duct
Air Inlet Canvas Duct (Field Supply)
The Cover (Field Supply) 3
(Field Supply)

Air Inlet
Air Outlet
Refrigerant Gas Pipe
The strainer is not standard,install it in Refrigerant Liquid Pipe
the air inlet piping.
Ensure the air inlet piping downwardto Drain Pipe
avoid a seeper.
Ensure the air outside can be inhaled ,or
the indoor unit will not work.
Perform the heat insulation work over the
duct for dew protection.
When metal lic duct and other wire
netting are used,ensure the duct
insulative from thewalls.
When welding the duct,do not leave
residue on the indoor unit. Gas Pipe Liquid Pipe Drain Pipe

154
R p1
screw thread
190

251
Discharge gas inside
And remove the cap

Gas Pipe Cool by a wet cloth

Liquid
Pipe
Drain P
ipe

12.17.2

An excess or a shortage of refrigerant is


the main cause of trouble to the units.
Charge the correct refrigerant quantity.

252
12.18 Drain Piping

The drain pipe must be installed as the following Do not connect the drain pipe with
figure to avoid bring scales due to the congeal and Sanitary or sewage piping or any other
leakage. drainage piping.
The positon of the drain piping When the comm on drain piping is
connection is shown below. connected with other indoor units
please install as follows .
The drain pipe can be installed at the left or
right side of the exit of the drain pipe.The Pour some water into the drain pan in
plug can be removed to invert into any side. order to test wether the water flows
sm oothly.
Open the cover ,pour about one litre of
The drain pipe should be as short as
water,test the draining status.
possible for the best effect.The pipe must
be performed with a DOWN-SLOP PITCH
to ensure that water flows smoothly.
Make sure the drain pipe thermal
insulated.
Install a trap at the drain outlet,because it below.
will bring splash or smell without it.
Keep the drain pipe flat in order to clean
the sediment.
Seal another drain pipe ,do up it using
thermal insulation .

Indoor Unit

The Bottom

Drain Plug
100 or more

Auxiliary Drain Pan Trap


(Field Supply) Common Drain Pipe
100 or more
100 or more

(1/100 Down-Slop at least)


(Do not lay into the water)

253
12.19
● All the materials and components Don not connect cable of remote control
should comply with local statutes. switch and operating wires with power
supplyand earth wires together.Keep
● Only brass wires are allowed. 50MM away from each other .
● Connect eletrical wires refering to the
Use appointed wires,and ensure the
circuit diagram.
terminal fixed.
● All the connection must be operated by
professionals.
● Install a breaker that can cut off the 12.19.1
wholesysterm.
● Grounded resistance must be less
Than100Ω .
● Connect the ground wire.
● If the fan reverse,adjust the phase.

12.19.2

below.

Cut out the center of the rubber bushing in the


wiring connection hole,as shown below.

Connect the cable of the remote control


switch to the connectors inside the
electrical box through the connecting hole in
the cabinet.

Connect th e power supply and earth wires to


the terminals in the electrical box.

Tightly clamp the sires using the cord clamp


inside the electrical box.
The elecrtrical wires should not contact with
gas pipe or liquid pipe.Make sure the pipe Seal the wiring connection hole after running
systerm insulated completely the cables with the seal meterial to protect
. the unit from condensate water or insects.
Make sure that the electrical wires are not
¡ñnipped into the electrical box or maintance
Connect the wires between the indoor unit
cover.
and outdoor unit to the terminals in the
¡ñ Do not connect the remote control unit electrical box.
wires with the power supply wires
together,or it may cause an abnormity.
¡ñ Do not connect diffent standard wires to
the same terminal.

254
Cut Inside
Rubber Bushing

Eletrical Box
Power Supply
Eletrical Box Cover 380-415V 3N~ 50Hz
ELB

Bolts Cable of Remote


Control Switch
Operating Wires

Cord Clamp

Maximum Power Source Cable Size Transmitting Cable Size


Model
Current EN60 335-1*1 EN60 335-1*1
2 2
AVA-154UX6SSH-400 3.48A 2.5mm 0.75mm
2 2
AVA-190UX6STH-500 4.46A 2.5mm 0.75mm
2 2
AVA-190UX6STH-600 5.46A 2.5mm 0.75mm

255
12.20 Test Run(For Model:154~190)

The wire sizes marked with *1 in the above table are selected
at the maximum current of the unit according to the European
Standard, EN60335-1.Use the wires which are not lighter than
the ordinary polyvinyl chloride sheathed flexible cord
(code designation H05VV-F).
3

Current(A) Wire Size(mm2 )


I≤3 2.5
3<l≤ 6 2.5
6<l≤10 2.5
10<I≤16 4
16<l≤25 6
25<l≤32 10
32<l≤50 16
50<l≤63 25
63<l Ć1

Ć1 In the case that current exceeds 63A, do not


connect cables inseries.

256
12.20.1
c 4
1

3 4

d DSW5&RSW2

2
8

a DSW6&RSW1

e Fuse Recover (DSW7)

f Optional Function Setting (DSW8)

Model 30 48

Model 76、154 96~114、190

257
13. 2-Way Cassette Type(AVL)
13.1 General Data
Indoor Unit Type 2-Way Cassette Type
Model AVL-07UXJSGA AVL-09UXJSGA AVL-12UXJSGA AVL-14UXJSGA
Power Supply AC 1 , 220-240V/50Hz AC 1 , 220V/60Hz
Nominal Cooling kW 2.2 2.8 3.6 4.5
Capacity kcal/h 1,900 2,400 3,100 3,900
Btu/h 7,500 9,600 12,300 15,400

Cooling Power Consumption kW 0.02 0.02 0.02 0.03


Nominal Heating kW 2.8 3.3 4.0 5.0
Capacity kcal/h 2,400 2,800 3,400 4,300
Btu/h 9,600 11,300 13,700 17,100

Heating Power Consumption kW 0.02 0.02 0.02 0.03


Sound Pressure Level
(Overall A Scale) dB 32--30-29-27 33-30-29-28 34-31-30-28 40-37-34-32
Outer Dimensions
Height mm 298 298 298 298
(in.) (11-3/4) (11-3/4) (11-3/4) 11-3/4)
Width mm 860 860 860 860
(in.) (33-7/8) (33-7/8) (33-7/8) (33-7/8)
Depth mm 630 630 630 630
(in.) (24-13/16) (24-13/16) (24-13/16) (24-13/16)
Net Weight kg 22 22 22 24
(lbs.) (48) (48) (48) (53)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 600/510/432/360 660/564/492/396 720/630/534/450 900/792/690/594
(cfm) (353/300/254/212) (388/332/289/233) (424/371/314/265) (530/466/406/350)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
(in.) (1/4) (1/4) (1/4) (1/4)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7
(in.) (1/2) (1/2) (1/2) (1/2)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.27 0.27 0.27 0.27
Adaptable Panel Model — HP-C-NA
Color — Silk White
Outer Dimensions
Height mm 30 30 30 30
(in.) (1-3/16) (1-3/16) (1-3/16) (1-3/16)
Width mm 1100 1100 1100 1100
(in.) (43-5/16) (43-5/16) (43-5/16) (43-5/16)
Depth mm 710 710 710 710
(in.) (27-15/16) (27-15/16) (27-15/16) (27-15/16)
Net Weight kg 7.5 7.5 7.5 7.5
(lbs.) (17) (17) (17) (17)
Approximate
Packing Measurement m3 0.10 0.10 0.10 0.10

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
19.0oC WB (66.2oF WB)

Outdoor Air Inlet Temperature: 35oC DB (95oF DB)


Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

258
Indoor Unit Type 2-Way Cassette Type
Model AVL-18UXJSGA AVL-24UXJSGA AVL-27UXJSGA AVL-30UXJSGA
Power Supply AC 1 , 220-240V/50Hz AC 1 , 220V/60Hz
Nominal Cooling kW 5.6 7.1 8.4 9.0
Capacity kcal/h 4,800 6,100 7,200 7,700
Btu/h 19,100 24,200 28,700 30,700

Cooling Power Consumption kW 0.04 0.05 0.07 0.08


Nominal Heating kW 6.5 8.0 9.0 10.0
Capacity kcal/h 5,600 6,800 7,700 8,600
Btu/h 22,200 27,300 30,700 34,100

Heating Power Consumption kW 0.04 0.05 0.07 0.08


Sound Pressure Level
(Overall A Scale) dB 42-39-36-33 45-42-39-36 47-44-40-36 49-46-42-37
Outer Dimensions
Height mm 298 298 298 298
(in.) (11-3/4) (11-3/4) (11-3/4) 11-3/4)
Width mm 860 860 860 860
(in.) (33-7/8) (33-7/8) (33-7/8) (33-7/8)
Depth mm 630 630 630 630
(in.) (24-13/16) (24-13/16) (24-13/16) (24-13/16)
Net Weight kg 24 24 24 24
(lbs.) (53) (53) (53) (53)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 1020/894/780/672 1140/984/858/738 1260/1104/936/756 1320/1158/978/786
(cfm) (601/526/459/594) (671/579/505/435) (742/650/551/445) (777/682/576/463)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ6.35 Φ9.53 Φ9.53 Φ9.53
(in.) (1/4) (3/8) (3/8) (3/8)
Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88
(in.) (1/2) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.27 0.27 0.27 0.27
Adaptable Panel Model — HP-C-NA
Color — Silk White
Outer Dimensions
Height mm 30 30 30 30
(in.) (1-3/16) (1-3/16) (1-3/16) (1-3/16)
Width mm 1100 1100 1100 1100
(in.) (43-5/16) (43-5/16) (43-5/16) (43-5/16)
Depth mm 710 710 710 710
(in.) (27-15/16) (27-15/16) (27-15/16) (27-15/16)
Net Weight kg 7.5 7.5 7.5 7.5
(lbs.) (17) (17) (17) (17)
Approximate
Packing Measurement m3 0.10 0.10 0.10 0.10

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
19.0oC WB (66.2oF WB)

Outdoor Air Inlet Temperature: 35oC DB (95oF DB)


Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

259
Indoor Unit Type 2-Way Cassette Type
Model AVL-38UXJSHA AVL-48UXJSHA AVL-54UXJSHA
Power Supply AC 1 , 220-240V/50Hz AC 1 , 220V/60Hz
Nominal Cooling kW 11.2 14.0 16.0
Capacity kcal/h 9,600 12,000 13,800
Btu/h 38,000 47,700 54,600

Cooling Power Consumption kW 0.09 0.11 0.12


Nominal Heating kW 13.0 16.0 18.0
Capacity kcal/h 11,200 13,800 15,500
Btu/h 44,000 54,600 61,400

Heating Power Consumption kW 0.09 0.11 0.12


Sound Pressure Level
(Overall A Scale) dB 46-44-40-38 48-45-42-38 49-46-43-40
Outer Dimensions
Height mm 298 298 298
(in.) (11-3/4) (11-3/4) (11-3/4)
Width mm 1420 1420 1420
(in.) (55-7/8) (55-7/8) (55-7/8)
Depth mm 630 630 630
(in.) (24-13/16) (24-13/16) (24-13/16)
Net Weight kg 39 39 39
(lbs.) (86) (86) (86)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 1800/1584/1386/1188 2100/1848/1614/1266 2220/1950/1704/1446
(cfm) (1060/933/816/670) (1237/1088/950/746) (1307/1148/1003/852)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53
(in.) (3/8) (3/8) (3/8)
Gas Line mm Φ15.88 Φ15.88 Φ15.88
(in.) (5/8) (5/8) (5/8)
Condensate Drain — VP25 VP25 VP25
Approximate
Packing Measurement m3 0.41 0.41 0.41
Adaptable Panel Model — HP-F-NA
Color — Silk White
Outer Dimensions
Height mm 30 30 30
(in.) (1-3/16) (1-3/16) (1-3/16)
Width mm 1660 1660 1660
(in.) (65-3/8) (65-3/8) (65-3/8)
Depth mm 710 710 710
(in.) (27-15/16) (27-15/16) (27-15/16)
Net Weight kg 10.5 10.5 10.5
(lbs.) (23) (23) (23)
Approximate
Packing Measurement m3 0.15 0.15 0.15

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
19.0oC WB (66.2oF WB)

Outdoor Air Inlet Temperature: 35oC DB (95oF DB)


Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

260
13.2 Dimensional Data
● AVL07_30*



Unit:mm


 






 
















 



● AVL38_54*





    














 

 

No. Name Remark


1 Turbo Fan
2
3
Motor
Heat exchanger

Model a b
4 Distributor 07 12.7 6.35
5 Filter
09 12.7 6.35
6 EXP. VALVE
12 12.7 6.35
7 Power souce
14 12.7 6.35
8 Refrigerant Gas Pipe Connection with φ a Flare Nut
18 12.7 6.35
9 Refrigerant Liquid Pipe Connection with φ b Flare Nut
10 24 15.88 9.53
Drain Pipe Connection VP25
11 Pump 27 15.88 9.53
12 Float SW 30 15.88 9.53
13 Water conncting plate 38 15.88 9.53
Panel P-AP90DNA with Model 07~30 Optional 48 15.88 9.53
14
P-AP160DNA with Model 38~54 54 15.88 9.53
15 Air Inlet grille
16 Air filter
17 Air Outlet
18 Air Inlet

261
13.3 Selection Data
● Service Space

AVL-07~54* Unit:mm

Min.
Min. 

Min. Min.
Min. Min.  
1 

Min. Piping Min.


 Connection


Min. Min.
Separated Installation  

Min. Piping
Connection
distance from wall side 

10 -20mm Closed Installation


298mm
Unit Hight in
False Celling
Unit Hight in False Celling

Min. Min.

Piping Connection Side

Min. Min.

Min.

Service Space

„ Sensible Heat Factor (SHF)

SHF
Indoor Unit Model
 AVL-07*
Hi

Me

Lo

AVL-09*   

 AVL-12* 
AVL-14* 






AVL-18*   

 AVL-24*
AVL-27*






AVL-30*   

 AVL-38*
AVL-48*






AVL-54*   

262
● Sound Data

Model:AVL-07* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVL-09* Power Supply: 220-240V/50Hz,220V/60Hz


Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


80 80

NC--70 NC--70
70 70
NC--65 NC--65

60 NC--60 60 NC--60
NC--55 NC--55

50 NC--50 NC--50
50

HH NC--45
HH NC--45
40 NC--40 NC--40
Hi 40
Hi
NC--35 NC--35
30 Me NC--30
30 Me NC--30
NC--25 NC--25
20 NC--20 NC--20
20
Lo NC--15 Lo NC--15
10
63 125 250 500 1000 2000 4000 8000 10
63 125 250 500 1000 2000 4000 8000
Central Frequency(Cycle per Second)
Central Frequency(Cycle per Second)

Model:AVL-12* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVL-14* Power Supply: 220-240V/50Hz,220V/60Hz


Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

80 80

NC--70 NC--70
70 70
NC--65 NC--65

60 NC--60 60 NC--60

NC--55 NC--55
HH Hi NC--50
50 NC--50 50
HH NC--45 Me NC--45
Hi NC--40 NC--40
40 40

Me NC--35 NC--35

30 NC--30 30 NC--30

NC--25 Lo NC--25

20 NC--20 20 NC--20
Lo
NC--15 NC--15

10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model:AVL-18* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVL24* Power Supply: 220-240V/50Hz,220V/60Hz


Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

80 80

NC--70 NC--70
70 70
NC--65 NC--65

60 NC--60 60 NC--60

NC--55 HH NC--55
HH Hi Hi
50 NC--50 50 NC--50
Me
Me NC--45 NC--45

40 NC--40 40 NC--40

NC--35 NC--35

NC--30
30 NC--30 30
Lo
Lo NC--25
NC--25

20 NC--20 20 NC--20

NC--15 NC--15

10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

263
Model:AVL-27* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVL-30* Power Supply: 220-240V/50Hz,220V/60Hz
Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
90 90
Noise Criteria Curve Noise Criteria Curve

Octave Sound Pressure Level(dB: Overall C Scale)


Octave Sound Pressure Level(dB: Overall C Scale)

80 80

NC--70 NC--70
70 70
NC--65 NC--65

60 NC--60 60 NC--60
HH HH
Hi NC--55 Hi NC--55
Me Me
50 NC--50 50 NC--50

NC--45 NC--45

40 NC--40 40 NC--40

NC--35 NC--35

30 NC--30 NC--30
Lo 30
Lo
NC--25 NC--25

20 NC--20 20 NC--20

NC--15 NC--15

10 10 8000
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model:AVL-38* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVL-48* Power Supply: 220-240V/50Hz,220V/60Hz

Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
90
90
Noise Criteria Curve Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

80
80
Octave Sound Pressure Level(dB: Overall C Scale)

NC--70
NC--70 70
70
NC--65
NC--65

60 NC--60
60 NC--60 HH Hi
HH NC--55
Hi NC--55 Me
Me 50 NC--50
50 NC--50
NC--45
NC--45
40 NC--40
40 NC--40
NC--35
NC--35

NC--30
30 Lo NC--30
30
Lo NC--25
NC--25
20 NC--20
20 NC--20
NC--15
NC--15
10
10 63 125 250 500 1000 2000 4000 8000
63 125 250 500 1000 2000 4000 8000
Central Frequency(Cycle per Second)
Central Frequency(Cycle per Second)

Model:AVL-54* Power Supply: 220-240V/50Hz,220V/60Hz


Measurement Point: 1.5 Meters Beneath the Unit
90
Noise Criteria Curve
Octave Sound Pressure Level(dB: Overall C Scale)

80

NC--70
70
NC--65
HH
60 NC--60
Hi
NC--55
Me
50 NC--50

NC--45

40 NC--40

NC--35

NC--30
30
Lo
NC--25

20 NC--20

NC--15

10
63 125 250 500 1000 2000 4000 8000

Central Frequency(Cycle per Second)

264
● Temperature Data
AVL-07UXJSGA
Cooling Heating
Discharge angle: 40° Air Flow rate: 600m³/h Discharge angle60° Air Flow rate: 600m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.5 1.5 1.5 1.5

2m 2m
0.9 0.9 0.9 0.9

0.6 0.6 0.6 0.6

1m 1m

0.3 0.3 0.3 0.3

0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m

18 18

1m 30 30 1m
24 24
19 27 27
19
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

AVL-09UXJSGA
Cooling Heating
Discharge angle: 40° Air Flow rate: 660m³/h Discharge angle: 46° Air Flow rate: 660m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.8 1.8 1.8 1.8

2m 2m
1.2 1.2
1.2 1.2

0.8 0.8 0.8 0.8


1m 1m

0.3 0.3
0.3 0.3
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m
16 16
33 33

1m 1m
30 30
18 18
20 20 25 28 28 25

0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

265
AVL-12UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 720m³/h Discharge angle60° Air Flow rate: 720m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.0 2.0 2.0 2.0

2m 2m
1.5 1.5 1.5 1.5

0.9 0.9
0.9 0.9
1m 1m

0.3 0.3
0.3 0.3
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m
16 16

32 32
18 18 1m 1m
25 25
20 28 28
20
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

AVL-14UXJSGA
Cooling Heating
Discharge angle: 40° Air Flow rate: 900m³/h Discharge angle: 60° Air Flow rate: 900m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.6 2.6 2.6 2.6

2m 2m
1.6 1.6
1.6 1.6

0.9 0.9 0.9 0.9


1m 1m

0.3 0.3
0.3 0.3
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36
26 26
2m 2m
15 15
34 34

1m 1m
17 17 31
31
19 19 28 28
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

266
AVL-18UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 1020m³/h Discharge angle:60° Air Flow rate: 1020m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
2.8 2.8 2.8 2.8

2m 2m
1.8 1.8 1.8 1.8

0.9 0.9

1m 0.9 1m
0.9
0.3 0.3
0.3 0.3
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m

17 17

1m 33 33 1m
19 19 27 27
18 29
18 29
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

AVL-24UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 1140m³/h Discharge angle: 60° Air Flow rate: 1140m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
3.2 3.2 3.2 3.2

2m 2m
1.5 1.5
1.5 1.5

0.9 0.9 0.9 0.9


1m 1m

0.3 0.3
0.3 0.3
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m
16 16
33 33
19 19

1m 1m
31 31
18 18 27 27
29 29
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

267
AVL-27UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 1260m³/h Discharge angle60° Air Flow rate: 1260m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
3.6 3.6 3.6 3.6

2m 2m
1.8 1.8

1.8 1.8

1m 1m
0.9 0.9
0.3 0.3
0.9 0.9 0.3
0.3
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m

19 16 16
19

1m 32 32 1m

18 30 30 28
18 28
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

AVL-30UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 1320m³/h Discharge angle: 60° Air Flow rate: 1320m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
3.8 3.8 3.8 3.8

2m 2m
2.0 2.0
2.0 2.0

1.4 1.4 1m 1m

0.3 0.8 0.8 0.3 0.3 0.8 0.8 0.3


0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m
16 16
34 34

1m 1m
19 19 32
32
18 18
28 30 30 28

0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

268
AVL-38UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 1800m³/h Discharge angle60° Air Flow rate: 1800m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
3.0 3.0 3.0 3.0

2m 2m
1.3 1.3
1.3 1.3
0.8 0.8
0.8 0.8
1m 1m

0.3 0.3
0.3 0.3
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m

16 16

1m 33 33 1m
28 28
18 17 18 30 30
17
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

AVL-48UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 2100m³/h Discharge angle: 60° Air Flow rate: 2100m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
3.4 3.4 3.4 3.4

2m 2m

1.5 1.5
1.5 1.5
0.9 0.9 1m 1m
0.9 0.9

0.3 0.3 0.3 0.3

0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m
16 16
34 34

1m 1m
32 32
17 17
18 18 30 31 31 30

0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

269
AVL-54UXJSGA

Cooling Heating
Discharge angle: 40° Air Flow rate: 2220m³/h Discharge angle60° Air Flow rate: 2220m³/h

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
3.6 3.6 3.6 3.6

2m 2m
1.5 1.5
1.5 1.5
0.9 0.9

1m 1m
0.9 0.9
0.3 0.3 0.3 0.3

0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

Temperature [°C] Temperature [°C]


2.7m 2.7m
14 14 36 36

2m 2m

18 18

1m 34 34 1m

17 17
32 32 30
30
0m 0m
5m 2.5m 0m 2.5m 5m 5m 2.5m 0m 2.5m 5m

270
13.4 Component Data

Model AVL-07* AVL-09* AVL-12* AVL-14*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 10 10 10 12
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.30 0.30 0.30 0.36
Number of Coil/Unit - 1 1 1 2
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 1 1 1 1
Outer Diameter mm 360 360 360 360
Revolution rpm 384/342/304/265 419/370/328/286 454/402/356/311 584/522/463/408
Nominal Air Flow m3/h 600/528/432/360 660/576/504/396 720/630/552/450 900/792/690/594
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 57 57 57 57
Quantity - 1 1 1 1
Insulation Class - E E E E

Model AVL-18* AVL-24* AVL-27* AVL-30*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 12 12 12 12
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.36 0.36 0.36 0.36
Number of Coil/Unit - 2 2 2 2
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 1 1 1
Outer Diameter mm 360 360 360 360
Revolution rpm 636/567/505/439 713/633/560/491 792/702/605/501 827/733/629/519
Nominal Air Flow m3/h 1020/870/780/672 1140/984/858/738 1260/1104/936/756 1320/1158/978/786
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 57 57 57 57
Quantity - 1 1 1 1
Insulation Class - E E E E

271
Model AVL-38* AVL-48* AVL-54*
Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0
Rows - 12 12 12
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15
Total Face Area m2 0.61 0.61 0.61
Number of Coil/Unit - 4 4 4
Indoor Fan Multi-Blade Centrifugal Fan
Number/Unit - 2 2 2
Outer Diameter mm 360 360 360
Revolution rpm 675(/607)/ 771(/694)/ 809(/728)/
606(/545)/ 690(/621)/ 723(/651)/
543(/488)/ 615(/554)/ 644(/580)/
479(/431) 504(/454) 562(/506)
Nominal Air Flow m3/h 1800/1584/1386/1188 2100/1848/1614/1266 2220/1950/1704/1446
Indoor Fan Motor Drip-Proof Type Enclosure
Starting Method - PSC (Permanent Split Capacitor)
Nominal Output W 57+57 57+57 57+57
Quantity - 2 2 2
Insulation Class - E E E

272
13.5 Refrigeration Cycle

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

b
Refrigerant Liquid Pipe Connection
S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

273
13.6 Electrical Data

Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT

AVL-07* 0.17/0.17 0.014/0.014


AVL-09* 0.17/0.17 0.014/0.014
AVL-12* 0.17/0.17 0.014/0.014
AVL-14* 0.27/0.27 0.024/0.024
2-Way
AVL-18* 220~ 1 50 264 198 1 0.37/0.37 0.034/0.034
Cassette
AVL-24* 240V 0.47/0.47 0.044/0.044
Type
AVL-27* 0.67/0.67 0.064/0.064
AVL-30* 0.67/0.67 0.074/0.074
AVL-38* 0.77/0.77 0.084/0.084
AVL-48* 0.97/0.97 0.104/0.104
AVL-54* 1.07/1.07 0.114/0.114

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

Safety and Control Device Setting

Model AVL-07~54*

For Control Circuit


Fuse Capacity A 5
Freeze Protection
Thermostat ºC 0
Cut-Out
Cut-In ºC 14

Thermostat
Differential ºC 2

274
13.7 Electrical Wiring Diagram

Models: AVL-07~54*

275
13.8 Indoor Unit Optional Parts

Optional Parts Applied Indoor Unit Type

Type Model 2-Way Cassette Type

HYXE-F01H
HYXE-G01H
Wire Remote Control Switch HYXE-A01H#01
HYXE-J01H
HYXE-M01H ●
Wireless Remote Control Switch HYE-L01
HYE-W01 ●
HYRE-V01H
HYRE-T01H
Wireless Receiver Kit
HYRE-V02H ●
HYRE-X01H
7 Day Timer HYDE-E01H
HYJE-H01H
HYJE-D02H
HYJ-J01H
Centrol Station HCCS-H128H2C1YM
HCCS-H128H2C1NM
HCCS-H247R4C1E
HCCS-H128H2C2NM
HC-A64BNP
Interface for Building Control
HCPC-H2M1C
HPS-162#E
Drain Pump HPS-132#E
HPS-151#E
HF-224L-FE
Long Life filter HF-280L-FE
HF-40L-ZFE
HP-DB-NK
3D Air Swing
HP-EB-NK

276
13.9 Factory-Supplied Accessories

2.3

Air Panel(optional)
Indoor Unit Panel Selected
07~30 HP-C-NA
38~54 HP-F-NA

(small)

(big)

(small)

(big)

(big)

(small)

For Power Wiring and


Cable Clamp
Transmission Wiring

277
13.10 Installation
13.10.1 Instal Check

below.

500mm Min.

500mm
100mm Min.
Min.

Piping
500mm Min. Connection

500mm Min.

100mm 500mm
Min. Min.

3000mm Min.

500mm
100mm Min.
Min.

Piping
500mm Min.
Connection

Distance from Wall Side

100mm Min. 1,500mm Min.

Piping
Connection Side

500mm Min.
1500mm Min.
1,000mm Min.

Service Space

Clearance 10 -20mm
298mm
Unit Hight in False
Ceiling

278
13.10.2 ●

10 Min.
4-Suspension Bolts
M10 or W3/8(Field-Supplied)

347
Nut(Field Supplied)
Washer(Accessory)

115

*47
30
Surface
of Ceiling
below.
*indicates the dimension between lower face of
A(Dimension of Opening)
Optional Panel (mm) indoor unit and surface of ceiling.
B(Dimension of Suspension Bolts)

Gas Pipe Connection 359

Suspension Bolts)
668(Dimension of

291

(Dimension of
Liquid Pipe Connection
211
Opening)

540
Drain Pipe Connection

347
260

50
208
Position of Piping
Suspension Bolts Connection Side
Panel

30
Position of Optical Sensor (if optical
sensor component is selected Air Inlet Grille

Unit: mm
70(Gas Pipe)
Model A B
70(Liquid Pipe)
07~30 1048 910 65 (Drain Pipe)

38~54 1608 1470


115

13.10.3

below.
Approx. 50

(mm)
For Concrete Slab For Steel Beam

Insert
150 to 160mm (100 to150kg)

Concrete
*
Steel
Anchor Bolt l Beam
(W3/8 or M10) Bracket
Suspension Bolt
(W3/8 or M10)
Approx. 65
115

For Wooden Beam

Wooden Rib
(60 to 90mm square timber)
Nut Square Washer

Square Washer
Nut
Wooden Beam Suspension Bolt

279
Drain Pipe
Fixing Bracket of Panel
Adjust four corners of
the system with a
plastic hose filled with
water

Suspension Bolt

Transparent
Plastic Hose

Bottom View

Suspension
Piping
Bracket
Connection Side

Drain Pan

Indoor Unit

Suspension Bolt

Ceiling

47
The fixing bracket is panel

● Connected to Ceiling

Indoor Unit

Connected to Indoor Unit


Ceiling

Dimension
of Opening
32

Adjustment Range
3-4mm

Fixing Bracket of Panel

Bolt M6
(Panel Accessories)

Pattern Board

280
13.11

10A Pipe Diameter (a)

Flaring
Diameter
(D)

13.11.1 below.

12.7mm 60
07 18

24~54

below.

13.11.2

below.

(mm)
Gas Pipe 359
Liquid Pipe 291
Drain Pipe 211
347
260
208

Panel(optional)

70 Gas Pipe
70 Liquid Pipe
65 Drain Pipe

Flaring Dimension
Perform the flaring work as shown below.

281
13.12 P Drain Hose

Horizontal or Upward Slope


Drain pipe must be installed horizontally or in upward slope
to prevent occurrence of air column, or otherwise water will
flow from rear of the equipment to cause leakage or
abnormal noise when the equipment is shut down.

(a) Use the drain pipe and hose clamp provided


by the manufacture.
(b) Do not impose too much force on the pipe
joint to prevent damage to it.
(c) Do not use any bent or twisted pipe, which
may cause leakage.
(d) Complete insert the drain pipe provided by
the manufacturer, or otherwise leakage may
be caused.
Drain Hose(Accessory)
Hose Band(Accessory)
Tightening Torque 2.5~3.4(N.m)
Elbow or Polyvinyl Chloride VP25
Drain Pipe
Connection

1.5or2.5
20+5
Insert Drain Pipe Completely to No Adhesive Agent Polyvinyl Chloride-based
End of The Hose Connection to be Adhesive Agent
(Correct)

1.5or2.5
(Incorrect) Twisted and Incomplete Insertion

section 13.11.2.

Ceiling
1- 1.5m Suspension
Bracket
a c
b

≤ 300) ( ≤50 )
≤ 850

1/25 to 1/100
Down-Slope
P
260

(mm)

Drain Hose
(Accessory)

950mm.

282
13.13
13.13.1

● Turn OFF the main power switch to the indoor


unit and the outdoor unit and wait for at least 3
minutes before electrical wiring work or a
periodical check is performed.
● Check to ensure that the indoor fan and the
outdoor fan have stopped before electrical
wiring work or a periodical check is performed.
● Protect the wires,drain pipe, electrical parts,
etc. from rats or other small animals.
If not protected, rats may gnaw at unprotected
parts and at the worst, a fire will occur.
● Avoid any wire from contacting with
Refrigerant tube, edge of metal plate and
electrical part in the equipment, or otherwise
the wire may be damaged or even thereby
cause fire.
● ELB with intermediate induction rate (with
shorter than 0.1 second or fewer) shall be
used, or otherwise electric shock or fire may
be caused.
● Wire shall be fixed securely, since external
force imposed to the connecting terminal may 13.13.2
make it loose and thereby cause fire.
● Do not use the power terminal strip used for next page.
the air conditioner to sub-connect any power
cable, but use power branch box to sub-
connect power wire at indoor unit side instead,
and be sure to calculate wire capacity, or
otherwise too low capacity may cause fire.
● The system shall not be started until all
inspections have been performed properly.

● Wrap the accessory packing around the wires,


and plug the wiring connection hole with the
seal material to protect the product from any
condensate water or insects.
● Tightly secure the wires with the cord clamp
inside the indoor unit.
● Secure the cable of the remote control switch
using the cord clamp inside the electrical box.
● Tighten screws according to the following
torque.
13.15
M3.5:1.2 N.m
M6:2.0~2.4 N.m

283
(a) Remove electrical box cover (by loosening one
Pipe screw (A)).
Baffle
(b) Loosen two screws (B) on electrical box
Wiring component and pull out the component.
Port (c) Fix the wire harness from connecting port to
electrical box with cord clamp to prevent it from
scratched by edge of container of other
component.
Base Board
(d) Mount a magnetic ring to the communication wire,
Electrical Box
which shall be wound by three circles around the
Screw(for fixing of
electrical box cover)
wire and then fixed with cord clamp provided in the
Electrical Box Cover
accessory bag.
07~30 (e) Upon completion of wiring, mount electrical box,
and take care not to press any wire.

Pipe
Baffle
Wiring •After wire is connected to terminal board, be
Port
sure to fix it with cord clamp and lay the wire in
cable tray to prevent it from being squeezed and
fire caused thereby.
Base Board
Electrical Box
Screw(for fixing of
Electrical
13.14
electrical box cover)
Box Cover Base
Board
Electrical
Box Cover

38~54

Wiring Hole Transmission


Terminal Board

Earth
Transmission Wiring
Screw
Remote Control Switch Cable
Power Source
Wiring

Power Terminal
Board
Wiring Hole

Electrical Box Cover


Fixing Screw

Transmission Terminal
Wiring Hole Board

Transmission Wiring
Remote Control
Switch Cable Cord Clamp

Power Source
Wiring

Wiring Hole
Earth Screw
Electrical Power Terminal
Box Board

Zoom-in View of Part A

284
13.15
13.15.1 13.15.2

Use an ELB (Electric Leakage Breaker).If not


used ,it will cause an electric shock or a fire. DSW5(Refrigerant Cycle No. Setting)
RSW2(Refrigerant Cycle No. Setting)
Run through the cables using conduit tube,
and Completely seal the end of conduit tube DSW3(Capacity Code Setting)
with sealing materials.
DSW7(Fuse Recover)

DSW6(Unit
MCA No. Setting) RSW1(Unit No. Setting)
EN60 335-1 *1 EN60 335-1 *1
DSW9(Optional Function Setting)
DSW4(Unit Mode Code Setting)
07 30 0.9A
2.5mm2 0.75mm2
38 54 1.8A 5

The wire sizes marked with *1 in the above table are selected
at the maximum current of the unit according to the European
Standard, EN60335-1.Use the wires which are not lighter than
the ordinary polyvinyl chloride sheathed flexible cord
(code designation H05VV-F).
3

Ex.) Set at No.16 Unit


Setting Set by inserting DSW6
Position Slotted screwdriver
Current(A) Wire Size(mm2 ) into the groove

I≤3 2.5 Set No.1 Pin ON


3<l≤ 6 2.5 Before shipment. DSW6 and RSW1 are set to "0".
RSW1
Max.64 units are available to set when all the equipment
6<l≤10 2.5 to be connected are corresponding to Hi-NET.
Max.16 units when the units corresponding/
10<I≤16 4 non-corresponding to Hi-NET are combined. Set at "6"

16<l≤25 6
25<l≤32 10
32<l≤50 16
50<l≤63 25
63<l Ć1

Ć1 In the case that current exceeds 63A, do not


connect cables inseries.

285
outlet

Outlet

(6) Optional Function Setting(DSW9)


No setting is required
Setting positions before shipment are all OFF
Setting the model code

13.17

13.17.1

13.16

Step 1
Remove the air returning decorative plate with
both hands,as shown below.
Step 2
Turn the buttons along edges of filter screen to
make them parallel to the slot, and then remove
the screen.

286
13.1

13.18.2

13.18.3

13.17.2

13.18.4

13.17.3

13.18

287
14. 1-Way Cassette Type(AVY)

14.1 General Data


Indoor Unit Type 1-Way Cassette Type
Model AVY-07UXJSJA AVY-09UXJSJA AVY-12UXJSJA AVY-14UXJSJA
Power Supply AC 1 , 220-240V/50Hz AC 1 , 220V/60Hz
Nominal Cooling kW 2.2 2.8 3.6 4.5
Capacity kcal/h 1,900 2,400 3,100 3,900
Btu/h 7,500 9,600 12,300 15,400

Cooling Power Consumption kW 0.02 0.02 0.03 0.03


Nominal Heating kW 2.5 3.2 4.0 5.0
Capacity kcal/h 2,200 2,800 3,400 4,300
Btu/h 8,500 11,000 13,600 17,100

Heating Power Consumption kW 0.02 0.03 0.04 0.04


Sound Pressure Level

Nominal Cooling dB 30/29/28/27/27/26 32/31/30/29/28/27 37/35/34/32/30/28 41/37/34/33/31/30

Nominal Heating dB 33/32/31/30/29/28 35/34/32/31/29/28 40/36/35/33/30/29 43/39/35/33/31/29


Outer Dimensions
Height mm 192 192 192 192
(in.) (7-9/16) (7-9/16) (7-9/16) (7-9/16)
Width mm 910 910 910 910
(in.) (35-13/16) (35-13/16) (35-13/16) (35-13/16)
Depth mm 470 470 470 470
(in.) (18-1/2) (18-1/2) (18-1/2) (18-1/2)
Net Weight kg 19 19 20 20
(lbs.) (42) (42) (44) (44)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 372/354/336/306/288/276 396/372/336/306/288/276 498/438/408/372/336/306 600/498/408/378/342/312
(cfm) (219/208/198/180/170/163) (233/219/198/180/170/163) (293/258/240/219/198/180) (353/293/240/223/201/184)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
(in.) (1/4) (1/4) (1/4) (1/4)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7
(in.) (1/2) (1/2) (1/2) (1/2)
Condensate Drain — VP25 VP25 VP25 VP25
Approximate
Packing Measurement m3 0.19 0.19 0.19 0.19
Adaptable Panel Model — HP-D-NA
Color — Neutral White
Outer Dimensions
Height mm 55 55 55 55
(in.) (2-3/16) (2-3/16) (2-3/16) (2-3/16)
Width mm 1100 1100 1100 1100
(in.) (43-5/16) (43-5/16) (43-5/16) (43-5/16)
Depth mm 550 550 550 550
(in.) (21-5/8) (21-5/8) (21-5/8) (21-5/8)
Net Weight kg 5 5 5 5
(lbs.) (11) (11) (11) (11)
Approximate
Packing Measurement m3 0.10 0.10 0.10 0.10
NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
19.0oC WB (66.2oF WB)

Outdoor Air Inlet Temperature: 35oC DB (95oF DB)


Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
288
Indoor Unit Type 1-Way Cassette Type
Model AVY-18UXJSKA AVY-24UXJSKA
Power Supply AC 1 , 220-240V/50Hz AC 1 , 220V/60Hz
Nominal Cooling kW 5.6 7.1
Capacity kcal/h 4,800 6,100
Btu/h 19,100 24,200

Cooling Power Consumption kW 0.04 0.08


Nominal Heating kW 6.3 8.0
Capacity kcal/h 5,400 6,900
Btu/h 21,500 27,300

Heating Power Consumption kW 0.05 0.10


Sound Pressure Level

Nominal Cooling dB 40/38/35/33/32/31 46/42/40/37/34/32

Nominal Heating dB 41/39/36/35/33/31 48/46/43/40/37/33


Outer Dimensions
Height mm 192 192
(in.) (7-9/16) (7-9/16)
Width mm 1180 1180
(in.) (46-7/16) (46-7/16)
Depth mm 470 470
(in.) (18-1/2) (18-1/2)
Net Weight kg 24 24
(lbs.) (53) (53)
Refrigerant — R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/h 726/594/528/492/468/396 936/756/672/594/504/426
(cfm) (427/350/311/290/275/233) (551/445/396/350/297251)

Connections Flare-Nut Connection (with Flare Nuts)


Refrigerant Piping
Liquid Line mm Φ6.35 Φ9.53
(in.) (1/4) (3/8)
Gas Line mm Φ15.88 Φ15.88
(in.) (5/8) (5/8)
Condensate Drain — VP25 VP25
Approximate
Packing Measurement m3 0.24 0.24
Adaptable Panel Model — HP-E-NA
Color — Neutral White
Outer Dimensions
Height mm 55 55
(in.) (2-3/16) (2-3/16)
Width mm 1370 1370
(in.) (53-15/16) (53-15/16)
Depth mm 550 550
(in.) (21-5/8) (21-5/8)
Net Weight kg 6 6
(lbs.) (13) (13
Approximate
Packing Measurement m3 0.12 0.12

NOTES:
1. The nominal cooling capacity is the combined capacity of the Hisense standard split system.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB)
19.0oC WB (66.2oF WB)

Outdoor Air Inlet Temperature: 35oC DB (95oF DB)


Heating Operation Conditions
Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

289
14.2 Dimensional Data
Model:07~14 10
Unit:mm





   



 




 

5 
     

Model:18~24
80





   












5 
     

No. Name
1 Turbo Fan
Remark

2 Motor
3 Heat Exchanger Model a b
4 Distributor 07 12.7 6.35
5 Filter
09 12.7 6.35
6 EXP. VALVE
12 12.7 6.35
7 Power Souce
14 12.7 6.35
8 Refrigerant Gas Pipe Connection with φ a Flare Nut
18 15.88 6.35
9 Refrigerant Liquid Pipe Connection with φ b Flare Nut
10 24 15.88 9.53
Drain Pipe Connection VP25
11 Pump
12 Float SW
13 Water Conncting Plate
14 Panel P-N45SNKQA with Model 07~14 Optional
P-N71SNKQA with Model 18~24
15 Air Inlet Grille
16 Air Filter
17 Air Outlet
18 Air Inlet

290
14.3 Selection Data

● Service Space

Unit:mm

Min
50

Min Piping
50 Connection
Min
500 Min.230mm

Min
500

Unit Hight in False Celling


distance from wall side

Min
PP
Min
PP
Piping
Connection

Min
PP
Min
PP Min
PP

Service Space

● Sensible Heat Factor (SHF)

SHF
Indoor Unit Model
Hi Me Lo
AVY-07* 0.82 0.72 0.67
AVY-09* 0.81 0.69 0.60
AVY-12* 0.77 0.72 0.68
AVY-14* 0.75 0.71 0.67
AVY-18* 0.74 0.70 0.67
AVY-24* 0.70 0.68 0.68

291
● Sound Data

Model:AVY-07* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVY-09* Power Supply: 220-240V/50Hz,220V/60Hz


Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
Noise Criteria Curve Noise Criteria Curve
90
90

Octave Sound Pressure Level(dB: Overall C Scale)


Octave Sound Pressure Level(dB: Overall C Scale)

80
80

70
NC-70 70
NC-70
NC-65
60 NC-65
NC-60 60
NC-60
NC-55
50 NC-55
NC-50 50
NC-50
HH NC-45 HH
40 Hi NC-45
NC-40 40 Hi
Me Me NC-40
Lo
NC-35 NC-35
30 30 Lo
NC-30 NC-30
20 NC-25 20 NC-25
S-Lo NC-20 S-Lo NC-20
night shift night shift
10 NC-15 10 NC-15
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model:AVY-12* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVY-14* Power Supply: 220-240V/50Hz,220V/60Hz


Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
Noise Criteria Curve Noise Criteria Curve
90 90
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

80 80

70 70
NC-70 NC-70
NC-65 NC-65
60 60
NC-60 NC-60
HH
NC-55 NC-55
50 50
HH NC-50 NC-50
Hi
Hi NC-45 Me
40 Me
NC-45
40 Lo
NC-40 NC-40
Lo
NC-35 NC-35
30 30
NC-30 NC-30
20 NC-25 NC-25
20
S-Lo NC-20 S-Lo NC-20
night shift night shift
10 NC-15 NC-15
10
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

Model:AVY-18* Power Supply: 220-240V/50Hz,220V/60Hz Model:AVY-24* Power Supply: 220-240V/50Hz,220V/60Hz


Measurement Point: 1.5 Meters Beneath the Unit Measurement Point: 1.5 Meters Beneath the Unit
Noise Criteria Curve Noise Criteria Curve
90 90
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

80 80

70 70
NC-70 NC-70
NC-65 NC-65
60 60
NC-60 NC-60
HH
NC-55 NC-55
50 50
HH NC-50 Hi NC-50
Hi NC-45 Me
40 NC-45
Me 40
NC-40 Lo NC-40
Lo NC-35
30 NC-35
30
NC-30 NC-30
20 NC-25 20 NC-25
S-Lo NC-20 S-Lo NC-20
night shift NC-15 night shift
10 10 NC-15
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

292
● Temperature Data
AVY-07UXJSJA
Cooling Heating
Discharge angle: 40° Air Flow rate: 372m³/h Discharge angle: 60° Air Flow rate: 372m³/h

Air velocity [m/s] Air velocity [m/s]

1.0
1.0
2m 2m
0.7
0.5

0.4 1m 1m
0.5
0.3
0.3
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

20 27
14
36
2m 2m
16

32
18
1m 1m
19

30
28 29
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

AVY-09UXJSJA
Cooling Heating
Discharge angle: 40° Air Flow rate: 396m³/h Discharge angle: 60° Air Flow rate: 396m³/h

Air velocity [m/s] Air velocity [m/s]

1.2 1.2
2m 2m

0.7

0.5 1m 0.7 1m

0.5
0.3
0.3
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

19 14 36

2m 2m
16

33
17
1m 1m

18
28
31
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Note: The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m
Fan operating mode is high.

293
AVY-012UXJSJA
Cooling Heating
Discharge angle: 40° Air Flow Rate: 498m³/h Discharge angle: 60° Air Flow Rate: 498m³/h

Air velocity [m/s] Air velocity [m/s]

1.4
1.4
2m 2m

0.8
0.8
0.5 1m 1m

0.3
0.5
0.3
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

19 27
14
36
2m 2m
16

32
17
1m 1m
18

30
28 29
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

AVY-14UXJSJA
Cooling Heating
Discharge angle: 40° Air Flow Rate: 600m³/h Discharge angle: 60° Air Flow Rate: 600m³/h

Air velocity [m/s] Air velocity [m/s]

1.6 1.6
2m 2m
1.2

0.8 1.2
1m 1m

0.5 0.8

0.3
0.3
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

19
14 36

2m 2m
16

33
17
1m 1m

18

29 31
30
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Note: The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m
Fan operating mode is high.

294
AVY-18UXJSJA
Cooling Heating
Discharge angle: 50° Air Flow Rate: 726m³/h Discharge angle: 60° Air Flow Rate: 726m³/h

Air velocity [m/s] Air velocity [m/s]

2.0
2.0
2m 2m

0.9

1m 0.9 1m
0.6
0.3 0.6
0.3

0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

18
14
38
2m 2m

15
36
16
1m 34 1m
17

30
32
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

AVY-24UXJSJA
Cooling Heating
Discharge angle: 40° Air Flow Rate: 936m³/h Discharge angle: 60° Air Flow Rate: 936m³/h

Air velocity [m/s] Air velocity [m/s]

2.7 2.7
2m 2m
1.6

1.2

0.8 1m 1.2 1m

0.8
0.3
0.3

0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

18 14 38

2m 2m
15

35
30
16
1m 1m

17
31
33
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Note: The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m
Fan operating mode is high.

295
14.4 Component Data
Indoor Heat Exchanger and Fan
Model AVY-07* AVY-09* AVY-12* AVY-14*
Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows - 2 2 3 3
Fin Material Aluminum
Pitch mm 1.6 1.6 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 0.15 0.15 0.15 0.15
Number of Coil/Unit - 1 1 1 2
Indoor Fan Centrifugal Fan
Number/Unit - 2 2 2 2
Outer Diameter mm 130 130 130 130
Revolution 705/687/660/ 786/740/687/ 1100/934/887/ 1250/1059/934/
rpm 633/608/586 633/608/586 820/750/687 887/820/750

Nominal Air Flow 372/354/336/ 396/372/336/ 498/438/408/ 600/498/408/


m3/h
306/288/276 306/288/276 372/336/306 378/342/312
Indoor Fan Motor IP20
Starting Method - Control software
Nominal Output W 40 40 40 40
Quantity - 1 1 1 1
Insulation Class - E E E E

Model AVY-18* AVY-24*


Heat Exchanger Type - Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0
Rows - 3 3
Fin Material Aluminum
Pitch mm 1.6 1.6
Maximum Operating Pressure MPa 4.15 4.15
Total Face Area m2 0.2 0.2
Number of Coil/Unit - 1 1
Indoor Fan Centrifugal Fan
Number/Unit - 3 3
Outer Diameter mm 130 130
Revolution 1159/980/890/ 1440/1196/1080/
rpm 843/803/710 980/855/750

Nominal Air Flow 726/594/528/ 936/756/672/


m3/h
492/468/396 594/504/426
Indoor Fan Motor IP20
Starting Method - Control software
Nominal Output W 60 60
Quantity - 1 1
Insulation Class - E E

296
14.5 Refrigeration Cycle

05~24Model

Indoor Unit

2
: Refrigerant Flow Direction (Cooling)
: Refrigerant Flow Direction (Heating)
: Field Refrigerant Piping
3 : Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

297
14.6 Electrical Data

< 50 Hz >
Indoor Unit
Unit Main Power Applicable Voltage Indoor Fan Motor
Model
VOL PH HZ Maximum Minimum PH RNC IPT

AVY-07* 0.17/0.17 0.014/0.014


AVY-09* 0.17/0.27 0.014/0.024
1-Way 220
AVY-12* 1 50/60 264 198 1 0.27/0.37 0.024/0.034
Cassette ~240/
Type AVY-14* 220V 0.37/0.47 0.034/0.044
AVY-18* 0.37/0.47 0.034/0.044
AVY-24* 0.57/0.67 0.074/0.094

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

Safety and Control Device Setting

Model AVY-07~24*

For Control Circuit


A 5
Fuse Capacity
Freeze Protection
Thermostat ºC 0
Cut-Out
Cut-In ºC 14
Thermostat ºC 2
Differential

298
AVY-07~24*

WARNING
14.7 Electrical Wiring Diagram
Before inspecting the electrical parts set the Operation Switch to
OFF, and cut OFF the power supply.

PCB1

TB1

Factory Wiring
Earth Wiring
Field Wiring
Optional Parts
Field Connection

CN19

MD
CN3 PCN12 CN1 MS1~3
FFC

PCB2
Field Connection

Air Panel

Alarm

Note :
1.. All the field wiring and equipme
must comply with local codes.

Operation Line

299
14.8 Indoor Unit Optional Parts

Optional Parts Applied Indoor Unit Type

Type Model 1-Way Cassette Type

HYXE-F01H
HYXE-G01H
Wire Remote Control Switch HYXE-A01H#01
HYXE-J01H
HYXE-M01H ●
Wireless Remote Control Switch HYE-L01
HYE-W01 ●
HYRE-V01H
HYRE-T01H
Wireless Receiver Kit
HYRE-V02H
HYRE-X01H ●
7 Day Timer HYDE-E01H
HYJE-H01H
HYJE-D02H
HYJ-J01H
Centrol Station HCCS-H128H2C1YM
HCCS-H128H2C1NM
HCCS-H247R4C1E
HCCS-H128H2C2NM

HC-A64BNP
Interface for Building Control
HCPC-H2M1C
HPS-162#E
Drain Pump HPS-132#E
HPS-151#E
HF-224L-FE
Long Life filter HF-280L-FE
HF-40L-ZFE
HP-DB-NK
3D Air Swing
HP-EB-NK

300
14.9

Air Panel(optional)
Indoor Unit Panel Selected
07~14 HP-D-NA
18~24 HP-E-NA

Screw 8

Magnet Ring 1

1 For Fixing Magnet Ring

301
14.10 Installation
14.10.1

below.

150mm Min. Service Hole(450Min.)

150mm Min.

500mm
Min.
1500mm Min. Piping
Connection

Distance From Wall Side

1,500mm Min.
150mm Min.
Piping
Connection Side

500mm Min.
150mm Min.
1,000mm Min.

Service Space

230mm Min.

302
14.10.2
● 14.10.3

Approx. 50
(mm)

below.
Bracket

28+3
(mm)

217
Dimension of Panel D
Dimension of Suspension Bolts C
Unit Size B Refrigerant
Outlet Pipe

20
Dimension of Panel 550

Suspension Bolts 450

Air Outlet

Unit Size 470


Dimension of

Dimension of
Opening 500
Indoor Unit

Panel
10

+20
Dimension of Opening A 0

Unit: mm
6L]HV $ % & '
0RGHO
$9<8;-6-$
$9<8;-6-$
   
$9<8;-6-$ (3) Use a gradienter or transparent plastic hose
$9<8;-6-$ filled with water to level the two directions of
$9<8;-6K$ indoor unit, length and width sides.
   
$9<8;-6K$

Suspension Bolt Gradienter

Suspension
Bracket

Piping
Connection
below. Side

For Concrete Slab For Steel Beam

Insert
150 to 160mm (100 to150kg) Transparent
Plastic Hose
Concrete
Steel
Anchor Bolt l Beam
(W3/8 or M10)
Suspension Bolt
(W3/8 or M10)

For Wooden Beam

Wooden Rib
(60 to 90mm square timber)
Nut Square Washer

If indoor unit is installed in a position inclined to


Square Washer
Nut the reverse direction, it may cause false
Wooden Beam Suspension Bolt
operation of float switch and there result in
leakage.

303
(4)
Pattern Board for Installation

Checking Scale 02
Checking Scale 01

● (2) Adjust the distance between indoor unit


and ceiling.
Adjust the indoor unit to a proper position
with the checking scale provided by the
Bottom View factory
(mm)

Ceiling
Air Outlet
Refrigerant Indoor Unit
Indoor Unit Outlet Pipe

Supported by
Dimension of
Opening Surface of Ceiling
Dimension of Opening

Connected to Indoor Unit

Side View
Fig. Adjustment of Distance to Indoor Unit
Suspension Bolt

(3) Cutting the Ceiling

Mount ceiling opening to the indoor unit with


screws (four) by using Pattern Board. Cut
the ceiling based on opening dimension of
the pattern board and mount the panel.

Adjustment Range
3-4mm

Panel Fixing Screw

Pattern Board

Bolt M6
(Panel Accessories)

After installation is completed, remove


the pattern board off the ceiling.

(1) Pattern Board for Installation is


provided in the packing,please cut it
off.

304
14.11

Pipe Diameter (a)


10A

Flaring
Diameter
(D)

below.
14.11.1

12.7mm 60

07 14

18

24

below.

14.11.2

below.
Drain Pipe Connection Liquid Pipe Connection Gas Pipe Connection
(PVC, VP25)

Flaring Dimension
Perform the flaring work as shown below.

305
14.12 P Drain Hose

Horizontal or Upward Slope


Drain pipe must be installed horizontally or in upward slope
to prevent occurrence of air column, or otherwise water will
flow from rear of the equipment to cause leakage or
abnormal noise when the equipment is shut down.

(a) Use the drain pipe and hose clamp provided


by the manufacture.
(b) Do not impose too much force on the pipe
joint to prevent damage to it.
(c) Do not use any bent or twisted pipe, which
may cause leakage.
(d) Complete insert the drain pipe provided by
the manufacturer, or otherwise leakage may
be caused.
Drain Hose(Accessory)
Hose Band(Accessory)
Tightening Torque 2.5~3.4(N.m)
Elbow or Polyvinyl Chloride VP25
Drain Pipe
Connection

2or2.5
20+5
Insert Drain Pipe Completely to No Adhesive Agent Polyvinyl Chloride-based
End of The Hose Connection to be Adhesive Agent
(Correct)

2
(Incorrect) Twisted and Incomplete Insertion

below.

Ceiling
1- 1.5m Suspension
Bracket
a c
b

≤ 300) ( ≤50 )
≤ 850

1/25 to 1/100
Down-Slope
115±4

(mm)

Drain Hose
(Accessory)

950mm.

306
14.13

14.13.1
● Turn OFF the main power switch to the indoor
unit and the outdoor unit and wait for at least 3
minutes before electrical wiring work or a
periodical check is performed.
● Check to ensure that the indoor fan and the
outdoor fan have stopped before electrical
wiring work or a periodical check is performed.
● Protect the wires,drain pipe, electrical parts,
etc. from rats or other small animals.
If not protected, rats may gnaw at unprotected
parts and at the worst, a fire will occur.
● Avoid any wire from contacting with
Refrigerant tube, edge of metal plate and
electrical part in the equipment, or otherwise
the wire may be damaged or even thereby
cause fire.
● ELB with intermediate induction rate (with
shorter than 0.1 second or fewer) shall be
used, or otherwise electric shock or fire may
be caused.
● Wire shall be fixed securely, since external
force imposed to the connecting terminal may
make it loose and thereby cause fire.
● Do not use the power terminal strip used for 14.13.2
the air conditioner to sub-connect any power
cable, but use power branch box to sub- below.
connect power wire at indoor unit side instead,
and be sure to calculate wire capacity, or
otherwise too low capacity may cause fire.
● The system shall not be started until all
inspections have been performed properly.

● Wrap the accessory packing around the wires,


and plug the wiring connection hole with the
seal material to protect the product from any
condensate water or insects.
● Tightly secure the wires with the cord clamp
inside the indoor unit.
● Secure the cable of the remote control switch
using the cord clamp inside the electrical box.
● Tighten screws according to the following
torque.
M4:1.0~1.3 N.m
M5:2.0~2.4 N.m
M6:4.0~5.0 N.m 14.15
M8:9.0~11.0 N.m
M10:18.0~23.0 N.m

307
Screw A (a) Remove electrical box cover (by loosening one
Screw B screw (A)).
Screw B
(b) Loosen two screws (B) on electrical box
component and pull out the component.
(c) Fix the wire harness from connecting port to
electrical box with cable clamp to prevent it
from scratched by edge of container of other
P component.
Cord Clamp
(d) Mount a magnetic ring to the communication wire,
Wire Hole which shall be wound by three circles around the
Base Board(two-layer)
wire and then fixed with cord clamp provided in the
accessory bag.
(e) Upon completion of wiring, mount electrical box,
and take care not to press any wire.

Electrical Box
Component •After wire is connected to terminal board, be
sure to fix it with cord clamp and lay the wire in
Electrical Box cable tray to prevent it from being squeezed and
Cover fire caused thereby.

Transmission Wiring 14.14

Power Source Wiring

Transmission Wiring
(between Indoor
Unit and Outdoor Unit)
R.C.S. Transmission

Remote Control
Switch Cable

Earth Screw

Power Source Wiring

308
14.15
14.15.1 14.15.2

DSW4(Unit Mode Code Setting)

Use an ELB (Electric Leakage Breaker).If not DSW3(Capacity Code Setting)

used ,it will cause an electric shock or a fire. DSW6(Unit No. Setting)

Run through the cables using conduit tube, RSW1(Unit No. Setting)
and Completely seal the end of conduit tube
DSW7(Fuse Recover)
with sealing materials.

MCA
EN60 335-1 *1 EN60 335-1 *1
RSW2(Refrigerant Cycle No. Setting)
07~09 0.3A
DSW5(Refrigerant Cycle No. Setting)

12 14 0.4A
2.5mm2 0.75mm2
18 0.5A 5

24 0.8A

The wire sizes marked with *1 in the above table are selected
at the maximum current of the unit according to the European
Standard, EN60335-1.Use the wires which are not lighter than
the ordinary polyvinyl chloride sheathed flexible cord
(code designation H05VV-F).
3

Ex.) Set at No.16 Unit


Setting Set by inserting DSW6
Position Slotted screwdriver
Current(A) Wire Size(mm2 ) into the groove

I≤3 2.5 Set No.1 Pin ON


3<l≤ 6 2.5 Before shipment. DSW6 and RSW1 are set to "0".
RSW1
Max.64 units are available to set when all the equipment
6<l≤10 2.5 to be connected are corresponding to Hi-NET.
Max.16 units when the units corresponding/
10<I≤16 4 non-corresponding to Hi-NET are combined. Set at "6"

16<l≤25 6
25<l≤32 10
32<l≤50 16 ON
OFF
50<l≤63 25
of the indoor unit.
63<l Ć1

Ć1 In the case that current exceeds 63A, do not


connect cables inseries.

309
Capacity
14.16
×10 Btu/h
3 07 09 12

Capacity
×10 3Btu/h 14 18 24

outlet

Outlet

310
14.17
Left Side

Knobs (two)

14.17.1
Zoom-in
View of Knob
Right side

Remove the other filter screen in the same way.

14.17.2

Left Side
Knob

Right Side

14.17.3

14.18

Note:
There are two grilles on the panel of
HP-E-NA, which should be removed
respectively.

311
14.18.1

14.18.2

14.18.3

14.18.4

312
 &RQVROH7\SH
 *HQHUDO'DWD

Indoor unit Console Type


AC 1φ,
Model Power Supply 220̚240V AVK-05HJFCAA AVK-07HJFCAA AVK-09HJFCAA AVK-12HJFCAA AVK-15HJFCAA AVK-17HJFCAA
/50Hz(60Hz)
kW 1.5 2.2 2.8 3.6 4.5 5.0
Nominal Cooling Capacity kcal/h 1300 1900 2400 3100 3800 4300
Btu/h 5100 7500 9600 12300 15300 17000
kW 2.0 2.5 3.3 4.2 5.0 5.6
Nominal Heating Capacity kcal/h 1700 2100 2800 3600 4300 4800
Btu/h 6800 8500 11200 14300 17000 19100

Cooling Power Consumption kW 0.01 0.011 0.012 0.014 0.018 0.023

Heating Power Consumption kW 0.01 0.011 0.012 0.014 0.018 0.023

Cooling Operating Current A 0.16 0.17 0.18 0.2 0.21 0.24

Heating Operating Current A 0.16 0.17 0.18 0.2 0.21 0.24

Type × Qty Turbo Fan × 1


([WHUQDO6WDWLF
3UHVVXUH3D 0 0 0 0 0 0
Fan
$LU)ORZ5DWH 270/282/306 318/336/360 336/360/384 318/342/372 384/396/432 438/474/510
6/R/R0H
/318/342/360 /384/420/444 /420/444/480 /408/456/492 /468/510/540 /540/582/606
+L++++ PK
1RLVH/HYHO 6OR/R0H+L++++ Sound Pressure-dB(A)      
Type DC DC DC DC DC DC
Motor
Output-W 30 30 30 30 30 30
Cabinet Color ² Pure White
Fuse Rating A 3.15A
Net Weight kg 16.1 16.1 16.1 17.4 17.4 17.4
Net Outer Dimensions WxHxD-mm 700x630x225 700x630x225 700x630x225 700x630x225 700x630x225 700x630x225
Gross weight kg 21.1 21.1 21.1 22.4 22.4 22.4
Packing Dimensions WxHxD-mm 790x725x315 790x725x315 790x725x315 790x725x315 790x725x315 790x725x315
Packing Volume m3 0.18 0.18 0.18 0.18 0.18 0.18
Piping Connections ² Flare-nut Connection(with Flare Nuts)
Liquid Line mm φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35
Gas Line mm φ12.7 φ12.7 φ12.7 φ12.7 φ12.7 φ12.7
Condensate Drain mm Outer Diameter φ18
Air filter ² 3(7/RQJ/LIH)LOWHU 3(7/RQJ/LIH)LOWHU 3(7/RQJ/LIH)LOWHU 3(7/RQJ/LIH)LOWHU 3(7/RQJ/LIH)LOWHU 3(7/RQJ/LIH)LOWHU
Hi-Motion HCM-S01E HCM-S01E HCM-S01E HCM-S01E HCM-S01E HCM-S01E
Optional Accessories
Humidity Sensor HCHR-S01E HCHR-S01E HCHR-S01E HCHR-S01E HCHR-S01E HCHR-S01E

、7KHQRPLQDOFRROLQJFDSDFLW\DQGKHDWLQJFDSDFLW\DUHEDVHGRQIROORZLQJFRQGLWLRQV Notes of console indoor unit connection:

&RROLQJ2SHUDWLRQ&RQGLWLRQV: 1、If the capacity of connected outdoor unit is


,QGRRU$LU,QOHW7HPSHUDWXUH℃'% ℉'% ℃:% ℉:%  not larger than 6HP(AVW-54*), the console
2XWGRRU$LU,QOHW7HPSHUDWXUH℃'% ℉'% indoor unit can run normally.
2、If the capacity of connected outdoor unit is
3LSLQJ/HQJWK0HWHUV3LSLQJ/LIW0HWHU larger than 6HP(AVW-54*). The following
restrictions must be observed.
+HDWLQJ2SHUDWLRQ&RQGLWLRQV:
,QGRRU$LU,QOHW7HPSHUDWXUH℃'% ℉'%
If the console indoor unit is running, the total
2XWGRRU$LU,QOHW7HPSHUDWXUH℃'% ℉'% ℃:% ℉:% capacity of the running indoor unit must be
larger than 1HP(2.8kW or 9kBtu/h).
The requirements must be guaranteed. If not,it
、7KHVRXQGSUHVVXUHOHYHOLVEDVHGRQIROORZLQJFRQGLWLRQV might cause condensation phenomenon on
upper air louvre.
,WLVPHDVXUHGLQDQHFKRLFURRP2SHUDWLRQQRLVHGLIIHUVZLWK
RSHUDWLRQDQGDPELHQWFRQGLWLRQV
/RFDWLRQRI0LFURSKRQH

313
 'LPHQVLRQDO'DWD
Models: AV.-05~17*

unit:PP

(OHFWULFDO
%R[

/LTXLG
SLSH

*DV
SLSH

:DWHU
RXWOHW

314
6HOHFWLRQ'DWD

Ɣ Service Space Models:


AV.-05~17*

≥300mm
≥50mm ≥50mm
3000~4000mm

Wall

Floor

Space for installation and service

● Sensible Heat Factor (SHF)


The sensible heat factor of indoor units at each fan speed (Hi, Me, Lo) is given in the below.

SHF
Indoor Unit Model
++ ++ +, 0( /2 6/2

AV.-05*      


AV.-07*      
AV.-09*      
AV.-12*    0.  
AV.-1*      0.5
AV.-17*      0.

315
Ɣ 6RXQG'DWD

Measurement Point: 1Meters From the Unit Service Cover Surface and 1 Meters From Floor Level.

Power Supply: 220-240V~50Hz/60Hz


Model: AV.-05* 0RGHO$9.*
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)


++
++ ++
++ /R
+L
/R +L
6/R 0H
0H
6/R

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

0RGHO$9.*
0RGHO$9.*
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

++
++
++
++ +L
/R /R
+L 0H
6/R
6/R
0H

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)

0RGHO$9.* 0RGHO$9.*
Octave Sound Pressure Level(dB: Overall C Scale)

Octave Sound Pressure Level(dB: Overall C Scale)

++
++ ++
++ /R +L
/R +L 0H
6/R
0H
6/R

Central Frequency(Cycle per Second) Central Frequency(Cycle per Second)


316
$9.*

%QQNKPI +HDWLQJ
Discharge angle: ° Discharge angle: °

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
     

2m 2m

1m 1m
 


     
0m 0m
m 1.5m m m m m 1.5m m m m

Temperature [°C] Temperature [°C]


2.7m 2.7m
   

 

2m 2m

1m 1m
   
 
 
   
0m 0m
m 1.5m m .5m m m 1.5m m .5m m

$9.*

%QQNKPI +HDWLQJ
Discharge angle: ° Discharge angle: °

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
      

2m 2m

1m 1m
  


     


0m 0m
m 1.5m m m m m 1.5m m m m

Temperature [°C] Temperature [°C]


2.7m 2.7m
   

 2m 2m


1m  1m
   
 
 
  
0m 0m
m 1.5m m .5m m m 1.5m m .5m m

317
$9.*

%QQNKPI +HDWLQJ
Discharge angle: ° Discharge angle: °

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
     

2m 2m

 1m  1m
 

     


0m 0m
m 1.5m m m m m 1.5m m m m

Temperature [°C] Temperature [°C]


2.7m 2.7m
   
 
2m 2m

1m 1m
   
 
  
 
0m 0m
m 1.5m m .5m m m 1.5m m .5m m

$9.*

%QQNKPI +HDWLQJ
Discharge angle: ° Discharge angle: °

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
      

2m 2m

1m  1m
  

     


0m 0m
m 1.5m m m m m 1.5m m m m

Temperature [°C] Temperature [°C]


2.7m 2.7m
   
 
 2m 2m

1m 1m
   
 
 
   
0m 0m
m 1.5m m .5m m m 1.5m m .5m m

318
$9.*

%QQNKPI +HDWLQJ
Discharge angle: ° Discharge angle: °

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
 
   

2m 2m

 1m  1m
 

     


0m 0m
m 1.5m m m m m 1.5m m m m

Temperature [°C] Temperature [°C]


2.7m 2.7m
    

2m 2m



1m 1m
   
 
 

 
0m 0m
m 1.5m m .5m m m 1.5m m .5m m

$9.*

%QQNKPI +HDWLQJ
Discharge angle: ° Discharge angle: °

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
     

2m 2m


1m  1m
 

    
0m 0m
m 1.5m m m m m 1.5m m m m

Temperature [°C] Temperature [°C]


2.7m 2.7m
  
 

 2m 2m


1m 1m
   
 
  
 
0m 0m
m 1.5m m .5m m m 1.5m m .5m m

319
 &RPSRQHQW'DWD

,QGRRU+HDW([FKDQJHUDQG)DQ

Model $9.* $9.* $9.*


Heat Exchanger Type  Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm .0 .0 
Rows    
Fin Material Aluminum
Pitch mm 1. 1. 1.
Maximum Operating Pressure MPa 4.15 4.15 4.15
Total Face Area m2   
Number of Coil/Unit  1 1 1
Indoor Fan 7XUER)DQ
Number/Unit    
Outer Diameter mm   

Nominal Air Flow m3/h   


Indoor Fan Motor '&PRWRU
Starting Method  (6RIWVWDUWLQJ)
Nominal Output W   
Quantity  1 1 1
Insulation Class  B % %

Model $9.* $9.* $9.*


Heat Exchanger Type  Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm .0 .0 
Rows    
Fin Material Aluminum
Pitch mm 1. 1. 1.
Maximum Operating Pressure MPa 4.15 4.15 4.15
Total Face Area m2   
Number of Coil/Unit  1 1 1
Indoor Fan 7XUER)DQ
Number/Unit    
Outer Diameter mm   

Nominal Air Flow m3/h   


Indoor Fan Motor '&PRWRU
Starting Method  (6RIWVWDUWLQJ)
Nominal Output W   
Quantity  1 1 1
Insulation Class  B % %

320
 5HIULJHUDWLRQ&\FOH

Indoor Unit

2
: Refrigerant Flow Direction
(Cooling) : Refrigerant Flow Direction
(Heating) : Field Refrigerant Piping :
3 Flare Connection

4
b

Refrigerant Liquid Pipe Connection


S

3 a

Refrigerant Gas Pipe Connection

Mark Part Name


1 Heat Exchanger
2 Distributor
3 Strainer
4 Micro-Computer Control Expansion Valve

321
 (OHFWULFDO'DWD

Indoor Unit

Unit Main Power Applicable Voltage Indoor Unit


Model
VOL PH Hz Maximum Minimum RNC IPT

AVK-05* 0.16 0.01


AVK-07* 0.17 0.011
AVK-09* 220~240 1 50 264 198 0.18 0.012
Console
Indoor Unit AVK-12* 0.2 0.014
AVK-15* 0.21 0.018
AVK-17* 0.24 0.023

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
PH: Phase (φ) IPT: Input (kW)
HZ: Frequency (Hz)

6DIHW\DQG&RQWURO'HYLFH6HWWLQJ
,QGRRU8QLW

Model AVK-05~17*

For Evaporator Fan


Motor Thermostat Cut-Out ą 110±5

Cut-In ą 92±5
For Control Circuit
Fuse Capacity A 3.15
Freeze Protection
Thermostat Cut-Out ą 0
Cut-In ą 14

Thermostat
Differential ą 2

322
15.7 Electrical Wiring Diagram
Model: AVK-05~17*

323
*OEPPS6OJU0QUJPOBM1BSUT

Optional Parts $SSOLHG,QGRRU8QLW7\SH

Type Model &RQVROH7\SH

HYXE-J01H Ⴠ
HYXE-J01H1 Ⴠ
Wire Remote Control Switch HYXE-J01H2 Ⴠ
HYXE-VA01 Ⴠ
HYXE-M01H Ⴠ
HYXM-VB01 Ⴠ
HYXM-VB01#01 Ⴠ
Wireless Remote Control Switch HYE-W01 Ⴠ VWDQGDUG
+XPLGLW\6HQVRU +&+56( Ⴠ
0RWLRQ'HWHFWRU HCM-S01E Ⴠ
7 Day Timer HYDE-E01H Ⴠ
HYJ-J01H Ⴠ
HYJM-S01H Ⴠ
Centrol Station HCCS-H128H2C1YM Ⴠ
HCCS-H128H2C1NM Ⴠ
+<-(++(+L0,7) Ⴠ $33
Interface for Building Control HCPC-H2M1C Ⴠ
HCH-160D Ⴠ
Switch Box
HCH-280D Ⴠ

324
15

7DEOH)DFWRU\6XSSOLHG$FFHVVRULHV

Installation Template 1 For Unit Hanging


And Adjustment

Pipe Insulation For Refrigerant


1 Piping Connection

electric
:LUH7LH 4

Mounting Plate 1 For Wall Install

Wireless Remote 1 For Controlling the


Control Unit

:LUH7LH 1 For fixing the magnetic ring


Magnetic Ring 1 For resisting EMI

325
15.10 Installtion
15.10.1
gInstall the indoor unit with a proper clearance around it for 15.10.2 ([SRVHG,QVWDOODWLRQ
operation and maintenance working space, as shown in below
Fig. 15.1. g ,nstallation 7emplate
gSelect the suitable areas to install the unit under approval of the  7HPSODWH%RDUGIRULQVWDOODWLRQLVLQWKHSDFNLQJ
user. FDUWRQRI LQGRRUXQLW
g The air passage is not blocked. 8VHLWWRGHFLGHDQLQVWDOODWLRQORFDWLRQDQGGLUHFWL
g Condensate can drain properly. RQRQ WKHXQLW
 3UHVVWKH7HPSODWH%RDUGWLJKWO\RQWRWKHVXUIDFH
gThe wall is strong enough to bear the weight of the indoor unit. GUDZRXWWKHKROHSRVLWLRQIRUVXVSHQVLRQEROWV
If there is a risk that the wall is not strong enough, reinforce the
wall before installing the unit. ZLWKDSHQFLO
 Drill a hole (65mm in diameter) in the spot indicatHG
gSufficient clearance for maintenance and servicing is ensured. by “○" symbol in installation template as below.
gWhen plural indoor units are installed nearby, keep them away  The location of the hole is different depending on
for more than 3-4m. which side of the pipe is taken out.
 Allow space around the pipe for aQ easier indoor unit
pipe connection.
Space for installation and service

Left Back Piping


≥300mm

Left Piping

≥50mm ≥50mm
3000~4000mm

Wall

Right Back Piping Left Bottom Piping


Right Piping

Floor Right Bottom Piping

Position for Mounting Plate


Fig. Space for installation and service

Left Back Piping

Left Bottom Piping Right Back Piping

Right Bottom Piping

Fig.15. Installation Template

326
 Boring a wall hole and installing wall
embedded pipe 3 Tabs

ā For walls containing metal frame or metal board,


be sure to use a wall embedded pipe and wall cover
Front Panel
in the feed-through hole to prevent possible heat,
electrical shock, or fire.
ā Be sure to caulk the gaps arounG the pipes with
caulking material to prevent water leakage.
Front Grille
(1) Bore a feed-through hole of 65mm in the wall
so it has a down slope toward the outside. 2 Tabs (1
(2) Insert a wall pipe into the hole. 7DEon the
(3) Insert a wall cover into wall pipe. Left)
(4) After completing refrigerant piping, wiring,
and drain piping, caulk pipe hole gap with putty.
Remove the Front Panel

Inside Outside

For Moldings
Unit Bottom Caulking Bottom Frame

Wall Hole
Cover (Field Remove the
Supplied) Pillar
Wall Embedded
Pipe (Field
Supplied)

 Installing indoor unit


Preparation
For Side Piping
 Open the front grille, remove the 4 screws and Bottom Frame
dismount the front panel while pulling it forward.

 Follow the procedure below when removing the Remove the Pillar
split portions.
○For0ROdings
 Remove the pillars. (Remove the slit portions on
the bottom frame using nippers.)
○ For iSde Piping
. Remove the slit portions on the bottom frame
using nippers.

CAUTION
. When you choose the left piping,you only need to remove the left pillars.
. When you choose the right piping,you only need to remove the right pillars.

327
 Installing styles +DOI&RQFHDOHG,QVWDOODWLRQ
Floor and wall installation Only items peculiar to this installation method are
given here.
gSecure using 6 screws for floor installations.(Do
not forget to secure to the wallEHKLQG.)

gFor wall installation, secure the mounting plate


using 5 screws and the indoor unit using 4 screws.
Wall 5HFHVV

gThe mounting plate should be installed on a wall gDrill a wall UHFHVV of the size shown in the illustration
which can support the weight of the indoor unit. on the right.
(1) Temporarily secure the mounting plate to the wall,
Open 6ize
make sure that the panel is completely level, 675~685mm
and mark the boring points on the wall.
(2) Secure the mounting plate to the wall with screws.
(3) Once refrigerant piping and drain piping connections
are completeG, fill in the gap of the through hole with

625~635mm
putty. A gap can lead to condensation on the 5HFHVV
refrigerant pipe and drain pipe, and the entry of iQVHFWV
Floor
LQWRWKHXQLW
(4) Attach the front panel and front grille in the original
positionsonce all connections are completeG.

Installation of supplemental plate

Floor Installation
gThe rear of the unit can be fixed with screws at the
points shown in the illustration below.
Be sure to install the supplemental plate in accordance
with the depth of the inner wall.
Unit: mm

644

Fixing 3oint Screw


on the %ack 5HFHVV Hole

150
150

250
230
6 Screws(M4x30mm)

Wall Installation Supplemental Plate


(Field Supplied)

Mounting Plate
73

(Unit: mm)
Supplemental Plate
(Field Supplied)

5 Screws(M4x30mm)
(Field Supplied)
250

200

4 Screws(M4x30mm) Molding

328
CAUTION
gThesupplementalplateforinstallingthemainunitmustbe
used or there will be a gap between the unit and the wall.

Installation RIindoor unit


1) Remove the front panel
(2) Attach the indoor unit to the wall and secure
using screws in 6 locations (M4x30mm).

6 Screws(M4x30mm)

CAUTION

gUse drain pan edge for horizontal projection of the indoor unit.
gInstall the indoor unit SDUDOOHO ZLWK wall.

329
&RQFHDOHG,QVWDOODWLRQ

Only items peculiar to this installation method are given here.

Install the unit according to the instructions below.Failure to do so may cause both cooling and
heating failure and the condensation inside the house.

(1) Allow enough space between the main unit and ceiling not to obstruct the flow of cool/warm air.
(2) Place a partition plate between outlet and inlet sections.
(3) Place a partition plate on the right side.
(4) Change the DQJOHRIXSSHUDLURXWOHWORXYHUWRHQDEOHVXFFHVVIXODLURXWSXW.
(5) Use a movable lattice at the air outlet to allow the adjustment of cool/warm air flow direction.
(6) Lattice size should be 70% or more of open rate.

Right side partition plate


(Unit: mm)

Right side partition plate

300 or more
50 or more 50 or more Upper lattice
must not
Partition plate project
Movable lattice

Partition plate
15~20

70% or more

470
of open rate

Partition plate
120

Movable lattice
40 or less

20~30

330
,QVWDOODWLRQ&KHFN

The levelness of installed machine must be corrected with a level.

CAUTION

gThe machine shall in no case be inclined opposite to the drain opening of water
pan, since this may lead to inefficient drainge.
KRUL]RQWDOPHWHU

 Fresh Air Intake


The unit refreshes your house with a pipe through the Fresh Air Intake.

Fresh Air Intake

331
5HIULJHUDQW3LSLQJ:RUN (2)

686789
68 59  686789
68 64
   8
6
6  6 6 68 68
7 !! "6 #9 $
69  6 12.7
86789
68 6%6 6878!9
 6 
6
6 8  98& 9
  6 4'66 67
6
866 86!6#
68$ #  $6
69 4( 986!!6 #6# 
!866# 98 9 8
6 886789
68 "6
$6#78 66 67 6 4
3LSLQJ0DWHULDOV
809+54-25406:;266<=7>--6,4?0;:--450-,-47*
829@464;303A40-,-,./07,B40C5:D03A40C:66:E,./
32F64*
3LSLQJ6L]H DD08,.*9
1:?46 Ž270+,-,./ ,>,?0+,-,./
05-17 Φ12.7(1/2) Φ6.35(1/4)

8‹9@464;30;642.0;:--450-,-47*0012J407>54 ()
3A4540,70.:0?>7302.?0D:,73>540,.7,?4*00I6:E
3A40,.7,?40:C03A40-,-470E,3A0.,35:/4.0:50?5<
2,5l03:054D:N402.<0?>730:50C:54,/.0D2345,267
F4C:540;:..4;3,./0-,-47*
3LSLQJ&RQQHFWLRQ
(1) The connection positions of the pipe are
shown in WKHILJXUHEHORZ
Left Back Piping )DFWRU\6XSSOLHG
Left Piping ,QVXODWLQJ6OHHYH

:LUH7LHIURP
$FFHVVRU\%DJ
Right Back Piping Left Bottom Piping
Right Piping ,QVXODWLQJ6OHHYH
Right Bottom Piping IURP$FFHVVRDU\
%DJ
Fig. The Connection Positions of the Tube

)LHOG6XSSOLHG
Cut out the knock-out hole along the groove in the ,QVXODWLQJ6OHHYH
Fover using saw blade to avoid sharp edges if
piping from right side.
Seal the clearance around pipes with seal material Fig. Banding Method for Gas Pipe
to prevent ingress of dirt and protect wires from Insulating Sleeve
damage by sharp edge after piping and wiring . The factory-suppliedDQGILHOGVXSSOLHGinsulating
sleeveV must be wrapped with the LQVXODWLQJ
VOHHYHIURPDFFHVVRU\EDJ, which must be then
tied tightly with two wire tiesDVVKRZQLQWKH
ILJXUHDERYH.Failure to do so may cause the
condenstate to damage the floor, which is likely
to result in customer complaints.

332
'UDLQ3LSLQJ
(1) Use commercial rigid polyvinyl chloride pipe
(outer diameter 26mm, inner diameter 20mm)
for drain pipe.
(2) The drain hose (315mm long) are supplied with
the indoor unit.
(3) The drain pipe should be inclined downward at
a gradient at least 1/100 so that water will flow
smoothly without any accumulation. (Should not be
trap.)
(4) Insert the drain hose to this depth (50mm or more)
so it won’t be pulled out of the drain pipe.
(5) Insulate the indoor drain pipe with 10mm or more of
insulation material to prevent condensation.
(6) Remove the air filters and pour some water
(approximately 1000cc) into the drain pan to check
LIthe water flows smoothly.

Must be no trap
INDOOR INDOOR
UNIT UNIT

:DWHUDFFXPXODWLQJLQWKHGUDLQSLSLQJFDQ
FDXVHWKHGUDLQWRFORJ
'RQRWWZLVWRUEHQGWKHGUDLQKRVHVRWKDW
H[FHVVLYHIRUFHLVQRWDSSOLHGWRLW
)DLOXUHWRGRVRPD\FDXVHZDWHUOHDNDJH

333
(OHFWULFDO:LULQJ  *HQHUDO&KHFN

Remove the
fixing screws
for elecrical
box
Draw out the
electrical box
toward the arrow
direction

Electrical Box
Cover

Fig.Remove electrical box

Elecrical box cover


Draw in the electrical
box cover toward the
arrow direction

Transmission Switch

1 2 A B TB2

Power line outlet


Cord clamp for transmission
wiring(between indoor unit
and outdoor unit)

Remove the fixing


screws for elecrical
box cover Power line

The edge of electrical box


cover should be embeded in Main PCB
electrical box. Elecrical box cover

Elecrical box cover


Fig. Remove Electrical Box Cover

334
 (OHFWULFDO:LULQJ&RQQHFWLRQ

WKHILJXUHEHORZ %HIRUHHOHFWULFDOZLULQJZRUNWXUQ2))WKHSRZHUVRXUFH
,IWKHFRQQHFWRUVDUHFRQQHFWHGZLWKRXWWXUQLQJ2))WKH
SRZHUVRXUFHWKHDXWRVZLQJORXYHUFDQQRWDFWLYDWH

7KHSRZHUVXSSO\DQGHDUWKZLUHVKDYHEHHQ Wired Remote Control Switch and Wireless Remote Control


FRQQHFWHGLQWKHIDFWRU\3OHDVHFRQQHFWWR Switch can not be used simultaneously .If Wired Remote
WKHSRZHUFLUFXLWZLWKD(/% WKHILJXUHEHORZ Control Switch is connected ,Disconnect Wireless Receiver
Wiring on the left side as viewed from the discharge grilles

5 Take out magnet ring and wire tie from


accessory bag,put the power line around the Remove the plastic cover
magnetic ring once and tie it tightly and disconnect wireless
receiver wiring

Put the power line


around the magnetic
ring once and tie it
tightly.

Power source
220-240V~
50/60Hz
Fig.Disconnect Wireless Receiver wiring
L:brown
N:blue
GND:green/yellow 7HVW5XQ
Power line

Remote Control Switch Cable

The Transmission Wiring


shall be attached to the
air pipe insulation sleeve
through wire tie and kept
away from the heat
exchanger.

Fig.

335
According to EN 60335-1
Current (A) Wire Size (mm2)
i≤6 2.5
6<i≤10 2.5
10<i≤16 2.5
16<i≤25 4
25<i≤32 6
32<i≤40 10
40<i≤63 16
&RPPRQ 63<i ※1
※1 In the case that current exceeds 63A,
)LHOG0LQLPXP:LUH6L]HVIRU3RZHU6RXUFH
do not connect cables in series.

Use an ELB (Electric Leakage Breaker).If not


used ,it will cause an electric shock or a fire.
Run through the cables using conduit tube,
and Completely seal the end of conduit tube
with sealing materials.

Power Maximum
Source Current EN60 335-1 *1 EN60 335-1 *1

05 0.A

07 A
220-240V
09 A
2.5mm 2 0.75mm2
12 50Hz A

15 A
17 A

The wire sizes marked with *1 in the above table are selected
at the maximum current of the unit according to the European
Standard, EN60335-1.Use the wires which are not lighter than
the ordinary polyvinyl chloride sheathed flexible cord
(code designation H05VV-F).
3

336
6HWWLQJRI'LS6ZLWFKHV

Refrigerant Cycle No. Setting

Unit No. Setting

 ([DPSOHRI0HWKRGIRU',36HWXS
     

0HWKRGIRU',36HWXSUHIHUWR()

the indoor unit.

337


15.16.1 Filter Removal and Installation

3
C
panel.

Removal 3URFHGXUH
Take out the air filter in the following steps.
Step1: Slide until the 2 stoppers click into place as shown.
Step2: Open the front grill and take out the air filter from the front panel.

Step 1 Step 2
Installation 3URFHGXUH
Step1: Insert the filter to the panel and aim the bottom hooks. Make sure the top hooks are
locked .
Step2: Close the front grill and slide until the 2 stoppers click into place as shown.

Step 1
Step 2
338
 