THG1335YGS Compressor Specifications
THG1335YGS Compressor Specifications
A low start torque in the THG1335YGS model implies that it requires less initial power to start, reducing the load on the electric grid and potential surge issues. However, it also means that the compressor might struggle to start under high load conditions or with sudden power demand changes .
The efficiency of the THG1335YGS model varies based on testing conditions. Under the ASHRAE 220V ~ 60HZ condition, the efficiency is 4.16 Btu/Wh, which indicates better performance compared to the CECOMAF 220V ~ 50HZ condition with an efficiency of 2.95 Btu/Wh, and ASHRAE 220V ~ 50HZ condition with an efficiency of 3.84 Btu/Wh .
Securing both IRAM and SGS listings for the THG1335YGS model is crucial for adhering to international quality and safety standards. It ensures the product is reliable, maintains high performance, and is marketable in jurisdictions requiring stringent compliance with regulatory and industrial standards .
The THG1335YGS operates within a voltage range of 180-242V at 50 Hz and 187-242V at 60 Hz. This flexibility allows it to function under varying power conditions, thus affecting its applicability and reliability in different geographic regions with varying power standards .
The THG1335YGS has a specified MCC of 0 amperes, suggesting this parameter is either negligible or tailored for specific conditions, which might lead to challenges in handling continuous high-load scenarios without potential overheating or efficiency losses .
The THG1335YGS shows different performance ratings when tested under AMBIENT TEMP conditions, notably at 55°C and 54°C. For example, changing ambient temperatures necessitate recalibration of conditions like return gas temperature to maintain operational efficiency and prevent overheating issues that could compromise performance .
Key specifications influencing the THG1335YGS model's use in low back pressure applications include its low start torque motor, operating within an evaporating temperature range of -34.4°C to -12.2°C, and using R-134a refrigerant, which is suitable for low temperature conditions .
Using polyolester oil with a viscosity of 10 cSt in the THG1335YGS provides enhanced lubrication efficiency across a broad temperature range. This type of oil offers better thermal stability, reduced friction, and compatibility with R-134a refrigerants, minimizing wear and improving the longevity of mechanical components .
The choice of R-134a refrigerant impacts the THG1335YGS model by defining its temperature ranges for evaporating and influencing efficiency at given conditions. It maintains a suitable performance across a wide application of low back pressure scenarios due to its chemical properties and thermodynamics, affecting operational efficiency differently at set ambient and liquid temperatures .
The main motor component has an electrical resistance of 18.85 Ohm, while the start motor component possesses a higher resistance of 29.8 Ohm. This higher start resistance likely results in a lower initial current draw, aiding in smoother start-ups, particularly crucial in devices with low start torque like the THG1335YGS .