CONTRIVE DESIGNS
Civil & Structural Engineers
E-mail: [email protected]
Construction of 4- lane Bridge Over Irang River on Imphal — Jiriba
Ni-37_ (Old NH-5S) in the state of Mainpuri on EPC mode
‘Client National Highways and Infrastructure Development Corporation Ltd,
‘Authority Engineer- SA INFRASTRUCTURE CONSULTANTS PVT. LTD,
WoRK:
Staging Load Calculation for PSC Girder
Material used for Shuttering,
1, Bottom Plates — 1250x800 mm.
2, Steel Runner of ISMB ~ 150X75X$ mm.
3, Vertical Column of 12 mtr. Height ,Size (450x450 mm) at the Spacing of 2m using
ng with 16 mm dia steel rod.
angle 50x50x6mm la
Dead Load:
a) Weight of Shuttering Plates ~ 14.76 MT ~ 144.75 kN
b) Weight of Steel runners (ISMB) —
5 MT- 35 KN
¢) Weight of Conerete ~ 50Cum ~ 1180.0 kN
d) Mise, load = 5 Kn
RS0030/2017
Live load: REGISTERED VALUER-A-25372
a) Taken as 2 KN (labor ete)
Total load = 144.75 + 35 + 1180.0 + 5 +2= 1366.75 Kn
Total no. of (BT) Vertical Column = 21 Nos.
Load on one (BT) Vertical Column = 1266.75/21 = 65.08CONTRIVE DESIGNS
Civil & Structural Engineers
E-mail: [email protected]
s STAAD.Pro Report
oe se 24/12/2021 ™* —ca/ Document
09:51:00
Job Information
Engineer Checked Approved
Name: vr. us ms
Date: 24Dee21
Project 10
Project Name
‘Structure Type SPACE FRAME
Number of Noses 1596 Highest Node 11004
[Number of laments 4164 Highest Beam sos
Number of Plazas 14 Highest Pato yi82
Number of Basic Load Cases 2
‘Nomber of Combination Lead Cases
‘netuded in tis printout are data for:
Al Tho Wmele Sucre
AGL
ER. MANINDER SINGH
B.E. (Civil) M.Tech, (STR.)
RS0030/2017
REGISTERED VALUER-A-25372CONTRIVE DESIGNS
Civil & Structural Engineers
E-mail: [email protected]
Fy STAAD.Pro Report
i mm 24/12/2021" cal Document]
09:54:00
Lead
Bl
é MY
ERS AARINDER SINGH
BE. (Givi) MTech. GTR.)
REGISTERED VALUER-A-25372CONTRIVE DESIGNS
Civil & Structural Engineers
E-mail: [email protected]
CALCULATION:
Provide 4 ISA 50x50x6 mm angle section
‘The relevant properties are
A=S68 mm?
Co= Cy = 14.5 mm
= 15.1 mm
Jax = Iyy = 12.9x10¢ mm
Area provided = 4x5680 = 2272 mr
Spacing of angles for allowable compressive stress of 120 mpa and Fy = 250 mpa
Allowable I/r = 64
0.65 x 12 x 10° = 7800 mm
7800/64
21.875 mm.
Moment of inertia of section required, 1 = Ar? = 2272 x 121.875? = 3374.72 x 10¢ mm?
Motnent of inertia of section required = Moment of inertia of section provided
3374.72 x 104 mm? =4 x 12.9.x 108+ 227292
Y= 121mm
Spacing of angles, S = 2 x (121+14.5) = 271 mm
Load carrying capacity = 120 x 2272 = 272 KN > 65.08 KN, Hence Safe
Conclusion:
Steel Column of Avg. 12.0m Height, size (450x450mm) at spacing 2000 mm are
safe for the total load of 1366.75 kN.
At,
ER. MANINDER SINGH
BE. (Civil) M.Tech. (STR.)
Rs0030/2017
REGISTERED VALUER-A-253722LES2V-ANTWA O3YS1SIOTY
LL0z/0g00S4
(as) “wal (ino) 8
HONIS YSQNINVI YA
NOLLVASS LNOWICONTRIVE DESIGNS
CIVIL AND STRUCTURAL ENGINEERS
MEERUT
so —
c= oa FP venticat on
1 HomuzonraL Racin
foo | os Lo |
SIDE ELEVATION
BE. (Givi) MTech. (STR,]
R80030/2017 )
REGISTERED VALUER-A-25372