(AHU) PDF Fcuk CTLG 2020 Ventilation 01
(AHU) PDF Fcuk CTLG 2020 Ventilation 01
VENTILATION
VENTILATION Lineup
Lineup
Airflow rate (m3/h) 250 350 500 800 1000
VENTILATION
Energy Recovery
Ventilator
UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100C
Connectable capacity class (kW) 5.0 6.3 8.0 10.0 12.5 14.0 20.0 25.0 40.0 50.0
DX-Kit
for Air Handling Applications
for VRF Outdoor Unit
EEV unit Control unit EEV unit Control unit EEV unit Control unit EEV unit Control unit
UTP-VX30A UTY-VDGX UTP-VX60A UTY-VDGX UTP-VX90A UTY-VDGX UTP-VX90A × 2 UTY-VDGX
DX-Kit
for Air Handling Applications
for Single Split Outdoor Unit
UTY-XDZXUK
Energy Recovery
Ventilator
228
Room air Supply air Room air
Inspection
cover
Reverse mountable direct air supply / exhaust system Straight
Reverse
mounted
unit unit
Adoption of straight air supply / exhaust system: Duct design is simplified because Inspection
the air supply / exhaust ducts are straight. hatch
Since each unit can be mounted in reverse position, only one inspection hole is
needed for two units: Two units can share one inspection hole so duct work is
Exhaust air Outside air Exhaust air
easier and more flexible.
Specifications
250 m3/h 350 m3/h 500 m3/h 800 m3/h 1000 m3/h
Model No. UTZBD025C UTZBD035C UTZBD050C UTZBD080C UTZBD100C
Power source 220 - 240V, 50Hz
Input power (Extra high)/High/Low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
(Extra high)/High/Low
I/s 69 / 69 / 52 97 / 97 / 66 138 / 138 / 122 222 / 222 / 175 277 / 277 / 194
Heat Exchange
Ventilation
External static pressure (Extra high)/High/Low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
Temperature Exchange
(Extra high)/High/Low % 75 / 75 / 77 75 / 75 / 78 75 / 75 / 76 75 / 75 / 76 75 / 75 / 79
Energy Exchange
(Extra high)/High/Low % 63 / 63 / 65 66 / 66 / 71 62 / 62 / 64 65 / 65 / 68 65 / 65 / 70
VENTILATION
Energy Exchange
(Extra high)/High/Low % 70 / 70 / 72 69 / 69 / 73 67 / 67 / 69 71 / 71 / 74 71 / 71 / 76
Sound pressure level (Extra high)/High/Low dB* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 37.5 / 35.5 / 32.5 37.5 / 37 / 34.5 38.5 / 37.5 / 34.5
Input power (Extra high)/High/Low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
Ventilation
m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
Normal
(Extra high)/High/Low
I/s 69 / 69 / 52 97 / 97 / 66 138 / 138 / 122 222 / 222 / 175 277 / 277 / 194
External static pressure (Extra high)/High/Low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
Sound pressure level (Extra high)/High/Low dB* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 38.5 / 38 / 32.5 37.5 / 37 / 34.5 40.5 / 39.5 / 36.5
Dimensions W×D×H mm 882 x 599 x 270 1050 x 804 x 317 1090 x 904 x 317 1322 x 884 x 388 1322 x 1134 x 388
Weight kg 29 49 57 71 83
Outlet duct diameter mm 150 150 200 250 250
Operation range °C -10 to 40 -10 to 40 -10 to 40 -10 to 40 -10 to 40
Maximum humidity % 85 85 85 85 85
* The noise level must be measured 1.5 m below the centre of the unit.
Dimensions
(Unit : mm)
229
VENTILATION
Energy
Recovery
Ventilator
Options
Energy recovery ventilator unit offers
maximum comfort and greater energy
savings.
ERV RELAY
This accessory will allow an Energy Recovery Ventilator unit to start &
stop in unison with the connected indoor unit
(There will be no control over on / off, fan speed or damper bypass)
230
Hard wired Control Interface
In order to use a Fujitsu hard-wired controller with the ERV units an interface
is required
• UTI-ERV2 interrface is supplied with an outside air intake duct sensor for control of the ERV
bypass damper e.g. heat recovery or "free cooling" bypass mode
• Dry contact terminals for remote on/off e.g. from BMS
• Allows the use of a Fujitsu UTY-RNNYM* hard wired controller which has the following features:
• Allows ERV fan speed selection from the remote controller
• Controller has an integral 7 day programmable time clock
• Controller has temperature selection for auto control of the damper
• Filter clean indicator facility
• Manual or Auto control of the bypass damper
VENTILATION
Description of the buttons on UTY-RNNYM remote 1. Start / Stop
2. Set Temperature
3. Master Control
4. Fan Control
5. ERV on/off
6. Timer mode (clock adjust)
7. Day (day off)
8. Set Back
9. Set Time
10. Delete
11. Set
12. N/A
13. N/A
14. Filter Button
15. Operation Lamp
16. Timer & Clock Display
17. Operation Mode Display
18. Fan Speed Display
19. Operation Lock Display
20. Temperature Display
21. Function Display
Delete
Set Button
231
VENTILATION
DX-Kit
for Air Handling Application
for VRF Outdoor Unit
These kits enable other manufacturers air handling units (AHU) and fan coil units (FCU) to be incorporated into a Fujitsu VRF system or, be
connected to a dedicated Fujitsu VRF outdoor unit as a 1:1 system to control outside air ventilation (AHU) or room temperature (FCU).
Air Handling
Unit
FCU
Control unit
When connecting to a fan coil unit, the
room temperature is controlled by the EEV unit
return air temperature sensor. DX-Kit
DX-Kit Thermistor Wired R.C.
Thermistor
Thermistor
Transmission line
External I/O DDC*
External I/O
Transmission line
Interface Thermistor
(Option) AHU or FCU
DX-Kit DX-Kit
AHU or FCU 3rd party
VRF Modbus External I/O Controller *DDC=Direct Digital Controller
Controller network
232
Functions Summary Inputs Outputs MODBUS® Control
• ON/OFF • ON/OFF indication Possible to control via a
• Setting temperature • Fan ON/OFF indication MODBUS enabled BMS by
• Capacity demand • Thermo ON/OFF indication using optional interface.
• Heating / Cooling operation • Defrost indication
mode • Fault indication
• Fault information
VENTILATION
Control unit: UTY-VDGX
EEV unit: UTP-VX30A / UTP-VX60A / UTP-VX90A
Specifications
Connectable Capacity class 5.0 kW 6.3 kW 8.0 kW 10.0 kW 12.5 kW 14.0 kW 20.0 kW 25.0 kW 40.0 kW 50.0 kW
Cooling 5.6 6.3 8.0 10.0 12.5 14.0 22.4 25.0 40.0 50.4
Capacity kW
Heating 6.3 7.1 9.0 11.2 14.0 16.0 25.0 28.0 45.0 56.5
233
VENTILATION
DX-Kit
for Air Handling Application
for Single Split Outdoor Unit
This kit enables other manufacturers air handling units (AHU) and fan coil units
(FCU) to be incorporated into a Fujitsu General Split outdoor unit.
Outdoor unit
Piping
3.5 kW 22.0 kW
DX-Kit
Smartphone
234
Functions Summary Inputs Outputs Wireless LAN Control
• ON/OFF • Status of Compressor, Wireless LAN control with cloud
• Heating/Cooling operation Defrost, Error (Potential free connectivity enables safe remote
mode relays) monitoring and control from
• Capacity demand (analogue • LED status indication anywhere.
0-10 V)
• Heat exchanger temperature
Easy installation
• Simple installation through compact DIN rail
mountable enclosure
• No need for expansion devise
• No separate external power required
VENTILATION
Model: UTY-XDZXUK
Specifications
BTU 12 14 18 24 30 36 45 54 60 72 90
Cooling 3.5 4.3 5.2 6.8 8.5 9.4 12.1 13.3 15.0 19.0 22.0
Capacity (Nominal) kW
Heating 4.1 5.0 6.0 7.8 10.0 10.8 13.3 15.8 18.0 22.4 27.0
235
VENTILATION
236
237
VENTILATION
VENTILATION
System Overview
AHU CONTROLLER
Controller line
VRF
Controller line
Transmission line
Transmission line
Piping line
238
The Advantages of the
NEW
System
VENTILATION
The system offers full comfort and air quality in the
buildings providing clean treated air thanks to the
AIR HANDLING UNIT advanced filtration and balanced temperature.
239
VENTILATION
AIRSTAGE™ Lineup
Fujitsu General provides multi air conditioning systems
for buildings AIRSTAGE™ Series matched to the size and
application of the property.
Capacity (kW) 28.0 33.5 40.0 45.0 50.4 55.9 61.5 67.0 73.5 78.5 85.0
HP 10 12 14 16 18 20 22 24 26 28 30
J-IVL Series
Space
Saving
V-III Series Heat Pump
AJY090 AJY108 AJY126 AJY144 AJY162 AJY180 AJY198 AJY216 AJY234 AJY252 AJY270
Set Model LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH
Energy
(IÀFLHQF\
240
90.0 95.0 100.5 107.0 112.0 118.5 123.5 130.0 135.0 140.0 145.0 150.0
32 34 36 38 40 42 44 46 48 50 52 54
AJY288 AJY306 AJY324 AJY342 AJY360 AJY378 AJY396 AJY414 AJY432 AJY450 AJY468 AJY486
LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH
VENTILATION
241
VENTILATION
Air inlet
sections
5 configurations are
Available
Configuration A
In line with Front Damper
For fresh air operation up to 100% external air
Configuration B
In line with Top Inlet Damper
For fresh air operation up to 100% external air
Configuration C
In line with Inlet Mixing Box
For fresh air operation up to 20% external air
Configuration D
Double Deck with Cross-Flow Heat
Exchanger
Configuration E
Double Deck with Thermal Wheel
Filters section
242
Coil section including built-in
expansion valve with PCB Electrical heating
section
control
Fan section
VENTILATION
3KRWR&RQÀJXUDWLRQ(
+XPLGLÀFDWLRQ
sections
Heat recovery
&URVVÁRZW\SH
Sound attenutor
sections
Heat recoveryy
Thermal wheel type
e
243
VENTILATION
Feature
3KRWR&RQÀJXUDWLRQ&
Structure
Section of extruded profile 62 × 62 mm (SNAP-IN system)
• The Airr Handling Units are manufactured with bearing framework and sandwich paneling.
• The frame
ame is made of extruded anticorodal aluminium alloy profiles of AlMgSi 0,5- UNI 9006/1
9006/ type.
ANTICORODAL
050 UNI 9006/1
2,70 20 ÷ 23 16 ÷ 20 12 ÷ 15 60 ÷ 70
EX UNI 3569 (6060)
ISO = Al Mg Si 0.5
Profile
• The exclusive bearing structure made by Fujitsu General, having actual dimension of 62 x 62 mm, uses
the lock panel system in aluminium (SNAP-IN system). This system permits to reach paneling tightnesses
beyond 2500 Pa (10 in WG), because of the homogeneity of the pressure over the paneling perimeter, not
achievable with the traditional system (selfdrilling screw fastening). This profile doesn’t require the aid of
internal and external screws, providing a more solid and aesthetically pleasing appearance.
• Because of the dimensions of the profile, the used panel has actual dimensions of 50 mm.
• The profile hasn’t got external sharp edges, as foreseen by the safety and accident-prevention rules in force.
• Air Handling Units are certified for the highest performance standards.
E r P LOT6 - 2018
• The EUROVENT certification on Fujitsu General units proves the reliability and correctness of declared
performance data and features.
• Fujitsu General units and all internal components are compliant to ErP EcoDesign 2018 LOT6 Regulation.
• The compliance of Fujitsu General units to UNI EN 1886 European Regulation about structure thermal and
mechanical performance is also certified by Eurovent.
(Unit : mm)
77
62 15
62
77
15
244
Panelling
The panelling is double skin sandwich type made of galvanised
sheet, with polyurethane foam insulation of minimum density 45
kg/m3, actual thickness: -50 mm Cold-rolled steel
Hot galvanising
Panels are made as follows:
Inner skin: Hot dipped galvanised sheet (galvanisation not less Phosphate coating
than 140 g/m2), 5/10 mm thick. Primer or back coat
Insulation: Rigid polyurethane foam minimum density 45 kg/m3, Finishing paint
thermal conductivity 0,018 ÷ 0,024 w/m2 °c.
Outer skin: Hot dipped pre-painted galvanised sheet
(galvanisation not less than 140 g/m2), 6/10 mm thick.
Hot dipped galvanised steel sheet type Fe P02 GZ 140 UNI En The bearing baseframe is made of galvanised steel with pressure
10142 with galvanisation not less than 140 g/m2. The thickness is bent, bolted or welded profile, according to the configuration of
VENTILATION
6/10 mm. the unit.
Pre-painted steel sheet 6/10 mm thick with base support made It is arranged for the sections lifting and suitable for water piping
of hot dipped galvanised steel (galvanisation not less than 140 passage and drain.
g/m2) EURONORM 142-79 and coating, colour white-grey for a Perimeter baseframes heights and profiles are dimensioned as
special resistance to weathering. The protective system consists of follows: H = 100 mm with bolted C profile for all units
a dry film of 25 μm on the exposed skin and of a dry film of 5 μm
The baseframes of all the above solutions are made of galvanised
on the non-exposed skin.
steel sheet with minimum thickness 2.0 mm.
Hardness of film: F on the Koh - i - Noor’s scale.
Other chemical-physical characteristics:
• Resistance beyond 250 h in salty mist (ECCA T8)
• Resistance beyond 1000 h in high humidity conditions (ASTM D
714)
• Film resistance to the cleaving and adhesion after bending
(ECCA T7).
A self-adhesive PVC film is laid on the steel sheet exposed surface
in order to avoid damages during the manufacturing procedures
SECTION VIEW.
and transport. The baseframe is flush with the panelling
245
VENTILATION
Filtration
Plate Filters COARSE 55%
Filtration
Bag Filters ePM1 50%
N.B. ePM1 50% bag filters are mandatory Soft bag filter features
for ECODESIGN ErP 2016 compliance
• Efficiency, ePM1 50%
• Depth 287 mm
• Fiberglass filtering stuff
• Galvanised steel sheet frame
• 80% of the material is recyclable
• Limit relative humidity 100%.
246
Thermal Exchange Sections
DX Coil
VENTILATION
Thermal Exchange Sections
Electrical Heating
247
VENTILATION
Fan Section
EC Inverter Plug-Fan
Humidifier
248
Heat Recovery Section
Cross Flow Heat Recovery
VENTILATION
The working principle is the following
• The exhaust air crosses half circular rotor sector and gives part of its heat to the
metallic mass. This, slowly wheeling, is invested from cold renewal air crossing
in counterflow the other half of the exchanger, taking the heat given from the
exhaust air. When the rotor is hygroscopic type, also humidity contained into the
exhaust air will be partially transferred to the renewal air.
• The words “warm air” and “cold air” of the above description are valid for winter
working cycle; in summer cycle the functions of transfer and absorption of heat and
humidity are evidently inverted.
249
VENTILATION
Dimensions
Configurations A
Electrical
1
Box
CPS0 PPTSF DX SV
Electrical
2
Box
Electrical
Box
3
CPS0 PPTSF DX PUV SV
Electrical
Box
4
CPS0 PPTSF DX PUV PEH SV
H W L L (with silencer)
Model name Config. kg
(mm) (mm) (mm) (mm)
250
Configurations B Configurations C
Electrical
Electrical
1 Box
1 Box
Electrical
Electrical
2 2
Box
Box
Electrical
Electrical
3 3
Box
Box
Electrical
Electrical
Box
4 4
Box
VENTILATION
H W L L (with silencer) L (with silencer)
Model name Config. kg Model name Config. H (mm) W (mm) L (mm) kg
(mm) (mm) (mm) (mm) (mm)
AHYB025GWAA 1 1,179 1,154 2,854 628 3,764 AHYC025GWAA 1 1,179 1,154 2,969 650 3,879
AHYB025GWAB 2 1,179 1,154 3,344 696 4,254 AHYC025GWAB 2 1,179 1,154 3,459 718 4,369
AHYB025GWAC 3 1,179 1,154 2,854 646 3,764 AHYC025GWAC 3 1,179 1,154 2,969 668 3,879
AHYB025GWAD 4 1,179 1,154 3,344 714 4,254 AHYC025GWAD 4 1,179 1,154 3,459 736 4,369
AHYB040GWAA 1 1,314 1,354 3,084 873 3,994 AHYC040GWAA 1 1,314 1,354 3,199 899 4,109
AHYB040GWAB 2 1,314 1,354 3,654 960 4,564 AHYC040GWAB 2 1,314 1,354 3,769 986 4,679
AHYB040GWAC 3 1,314 1,354 3,084 894 3,994 AHYC040GWAC 3 1,314 1,354 3,199 920 4,109
AHYB040GWAD 4 1,314 1,354 3,654 981 4,564 AHYC040GWAD 4 1,314 1,354 3,769 1,007 4,679
AHYB048GWAA 1 1,424 1,574 3,084 953 3,994 AHYC048GWAA 1 1,424 1,574 3,199 980 4,109
AHYB048GWAB 2 1,424 1,574 3,654 1,055 4,564 AHYC048GWAB 2 1,424 1,574 3,769 1,082 4,679
AHYB048GWAC 3 1,424 1,574 3,084 976 3,994 AHYC048GWAC 3 1,424 1,574 3,199 1,003 4,109
AHYB048GWAD 4 1,424 1,574 3,654 1,078 4,564 AHYC048GWAD 4 1,424 1,574 3,769 1,105 4,679
AHYB080GWAA 1 1,659 2,074 3,624 1,591 4,534 AHYC080GWAA 1 1,659 2,074 3,739 1,624 4,649
AHYB080GWAB 2 1,659 2,074 4,274 1,749 5,184 AHYC080GWAB 2 1,659 2,074 4,389 1,782 5,299
AHYB080GWAC 3 1,659 2,074 3,624 1,619 4,534 AHYC080GWAC 3 1,659 2,074 3,739 1,652 4,649
AHYB080GWAD 4 1,659 2,074 4,274 1,777 5,184 AHYC080GWAD 4 1,659 2,074 4,389 1,810 5,299
AHYB096GWAA 1 1,904 2,250 3,724 1,760 4,634 AHYC096GWAA 1 1,904 2,250 3,839 1,799 4,749
AHYB096GWAB 2 1,904 2,250 4,374 1,936 5,284 AHYC096GWAB 2 1,904 2,250 4,489 1,975 5,399
AHYB096GWAC 3 1,904 2,250 3,724 1,790 4,634 AHYC096GWAC 3 1,904 2,250 3,839 1,829 4,749
AHYB096GWAD 4 1,904 2,250 4,374 1,966 5,284 AHYC096GWAD 4 1,904 2,250 4,489 2,005 5,399
251
VENTILATION
Configurations D Configurations E
1 Electrical
Box
1 Electrical
Box
2 Electrical
Box
2 Electrical
Box
3 Electrical
Box
3 Electrical
Box
4 Electrical
4 Electrical
Box Box
252
Silencer PI
Loose Accessories
VENTILATION
Galvanised metal sheet roof
All units that must be positioned outside or generally speaking
are exposed to the weather may be equipped with a hot-
galvanised metal sheet roof (galvanisation not less than 140 g/
Connectable AHU model name H (mm) L (mm) W (mm) Kg m2) an accessory element.
The roof overhang with regard to the unit outer dimensions is
AHY* 025GWA* 1064 910 1154 209 of about 100 mm. All roof corners are equipped with accident
AHY* 040GWA* 1199 910 1354 233
prevention protections.
253
VENTILATION
m3/h Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa
10HP 025 NOM 4,500 1 13 98 158 59 28 210 122 95 167 93 146 165 95 8 - -
14HP 040 NOM 7,200 2 13 87 149 68 10 240 145 87 172 93 144 169 94 8 - -
18HP 048 NOM 8,600 1 13 97 156 55 11 241 155 93 178 95 149 176 93 10 - -
254
Fan Characteristic Curves
1,400
1,200
1,000
800
600
400
1,100
1,650
200
2,400
0 1,950
0 2,000 4,000 6,000 8,000 10,000
VENTILATION
Pa n LwAin LwAout
fan type m3/h W
Total static pressure [1/min] [dB] [dB]
400 mm 156 265 124 1100 63 71
400 mm 334 265 134 1100 63 70
400 mm 1002 265 187 1100 62 69
400 mm 1025 265 181 1100 62 69
400 mm 2072 228 234 1100 58 66
400 mm 3275 119 224 1100 62 69
400 mm 3809 16 173 1100 69 74
400 mm 223 622 352 1650 75 82
400 mm 2005 591 642 1650 72 79
400 mm 3564 493 767 1650 68 75
400 mm 4656 321 708 1650 71 77
400 mm 5770 21 487 1650 79 83
400 mm 200 840 509 1950 79 86
400 mm 3163 783 1154 1950 74 81
400 mm 4946 570 1223 1950 74 80
400 mm 5948 316 1027 1950 78 83
400 mm 6750 41 773 1950 83 87
400 mm 245 1276 921 2400 85 92
400 mm 1649 1244 1497 2400 86 92
400 mm 4163 1165 2223 2400 81 87
400 mm 6438 783 2237 2400 81 87
400 mm 7864 296 1738 2400 86 91
400 mm 8510 10 1389 2392 89 93
255
VENTILATION
1,200
1,000
800
600
400
800
200 1,200
1,400
0 1,550
0 5,000 10,000 15,000 20,000
Pa n LwAin LwAout
fan type m3/h W
Total static pressure [1/min] [dB] [dB]
560 mm 158 276 209 800 65 72
560 mm 1861 270 345 800 65 71
560 mm 3921 236 438 800 61 67
560 mm 5980 130 452 800 62 67
560 mm 7881 4 313 800 69 74
560 mm 158 627 591 1200 77 83
560 mm 3327 596 1164 1200 75 82
560 mm 6139 547 1471 1200 71 77
560 mm 8950 386 1473 1200 72 78
560 mm 10653 190 1212 1200 76 82
560 mm 11921 11 936 1200 80 85
560 mm 238 837 901 1400 80 87
560 mm 3446 824 1743 1400 80 87
560 mm 8000 715 2403 1400 75 81
560 mm 10693 493 2260 1400 76 82
560 mm 12475 243 1859 1400 80 86
560 mm 13861 38 1521 1400 85 89
560 mm 198 1046 1210 1550 84 90
560 mm 2812 995 2086 1550 84 91
560 mm 7485 939 3131 1550 78 84
560 mm 10059 774 3249 1550 77 84
560 mm 13188 453 2901 1550 82 88
560 mm 15564 2 1948 1550 91 94
256
Fan type 710 mm
1,600
1,400
1,200
1,000
800
600
400
700
1,000
200
1,250
0 1,400
0 5,000 10,000 15,000 20.000 25,000 30,000
VENTILATION
Pa n LwAin LwAout
fan type m3/h W
Total static pressure [1/min] [dB] [dB]
710 mm 891 361 744 700 71 77
710 mm 4975 332 1290 700 69 74
710 mm 10025 196 1427 700 69 75
710 mm 13515 6 880 700 77 83
710 mm 1708 788 1693 1000 81 88
710 mm 9876 670 3179 1000 77 83
710 mm 16634 338 3084 1000 80 86
710 mm 20124 24 2177 1000 87 93
710 mm 2228 1179 3015 1250 87 94
710 mm 15297 901 6054 1250 83 89
710 mm 20495 563 5794 1250 86 92
710 mm 25173 12 3857 1250 92 98
710 mm 1821 1421 3716 1400 89 96
710 mm 7500 1380 5851 1400 89 95
710 mm 17996 1110 8301 1400 86 92
710 mm 24855 445 6916 1400 91 98
710 mm 27685 40 5271 1400 95 101
257
VENTILATION
Specifications
Configuration A-B-C
Casing Casing
Material Outer skin in 0.6 mm pre-painted galvanised sheet; inner skin in 0.6 mm galvanised sheet Material
Insulation PU foam, 50 mm thickness, 45 kg/m3 Insulation
Performances Performances
Cooling capacity kW 25 40 48 78 96 Cooling capacity kW
Heating capacity kW 31.5 45 50 81.5 100 Heating capacity kW
Available static pressure Pa 200 200 200 200 200 Available static pressure Pa
Power supply V/Ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Power supply V/Ph/Hz
$LUÁRZ $LUÁRZ
Max m³/h 5000 8000 9100 16100 18100 Max m³/h
Rated m³/h 4500 7200 8600 14500 17300 Rated m³/h
Min m³/h 4300 5000 8100 11000 16000 Min m³/h
Cross flow heat recovery Heat recovery
Efficiency (*) % – – – – – Efficiency (*) %
Eurovent Energy Class (**) Eurovent Energy Class (**)
Rated A+ A A A A Rated
DX Coil DX Coil
Rows n° 4 Rows n°
Coil type 25x22 - 3/8" Coil type
Coil duty Cooling - Heating Coil duty
Fluid R410A Fluid
Pipes material Copper Pipes material
Fins material Aluminium Fins material
Electrical heating Electrical heating
Stages n° 3 Stages n°
Heating capacity kW 9 15 18 30 36 Heating capacity kW
+XPLGLÀHU +XPLGLÀHU
Fix steam capacity kg/h 15 25 30 45 60
Fan Fan
Type EC Plug Fan Type
mm 400 560 560 710 710 mm
Motor data Motor data
kW 2.4 3.4 3.4 7.3 7.3 kW
DWUDWHGDLUÁRZ
(**) configuration 1
258
Configuration D Configuration E
025 040 048 080 096 025 040 048 080 096
AHYD025GWA* AHYD040GWA* AHYD048GWA* AHYD080GWA* AHYD096GWA* AHYE025GWA* AHYE040GWA* AHYE048GWA* AHYE080GWA* AHYE096GWA*
Outer skin in 0,6 mm pre-painted galvanised sheet; inner skin in 0,6 mm galvanised sheet Outer skin in 0,6 mm pre-painted galvanised sheet; inner skin in 0,6 mm galvanised sheet
PU foam, 50 mm thickness, 45 kg/m3 PU foam, 50 mm thickness, 45 kg/m3
25 40 48 78 96 25 40 48 78 96
31.5 45 50 81.5 100 31.5 45 50 81.5 100
200 200 200 200 200 200 200 200 200 200
400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
5000 8000 9100 16100 18100 5000 8000 9100 16100 18100
4500 7200 8600 14500 17300 4500 7200 8600 14500 17300
4300 5000 8100 11000 16000 4300 5000 8100 11000 16000
73.3 74.4 74.2 73.7 73.6 75.6 74.7 74.2 75.3 75.6
VENTILATION
A+ A+ A+ A+ A A+ A+ A+ A A
4 4
25x22 - 3/8" 25x22 - 3/8"
Cooling - Heating Cooling - Heating
R410A R410A
Copper Copper
Aluminium Aluminium
3 3
9 15 18 30 36 9 15 18 30 36
15 25 30 45 60 15 25 30 45 60
2.4 3.4 3.4 7.3 7.3 2.4 3.4 3.4 7.3 7.3
T3 T3 T3 T3 T3 T3 T3 T3 T3 T3
TB3 TB3 TB3 TB3 TB3 TB3 TB3 TB3 TB3 TB3
D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M)
L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M)
>L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M)
F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M)
DWUDWHGDLUÁRZ
(**) configuration 1
259
VENTILATION
Control System
AHU Controller
UTY-TXUX
Features
• Easy to install. Control connects to AHU PLC.
• Able to install the control after building decoration.
• Mode lock function: user can lock the running mode of Air Handling Unit.
Easy Opration
The remote controller realised an intuitive operation feeling by touch panel
operation.
Functions
• Schedule setting change
• Set temperature and humidity
• Ambient’s name
• Alarms setting
• Event setting
Specifications
Model name UTY-TXUX
Format mm 120 x 86 x 25
Display Display touch color 3.5” 320 x 240
Power supply 24 Vac - 24 Vac/dc
Analogue inputs 1 x Integrated NTC
Connectivity RS485 - Modbus SL, USB Micro-B (debug and programming)
Operating temperature 0 – +50 °C
260
System Controller System Controller Lite
UTY-APGXZ1 UTY-ALGXZ1 + UTY-PLGXX2
Features Features
System Controller realises the advanced integrated monitoring System Controller Lite has standard functions sufficient for
& control of VRF network system from small scale buildings to air conditioner management in small and medium scale
large scale buildings. buildings.
• Up to a maximum of 4 VRF network systems, 1,600 indoor • Up to a maximum of 1 VRF network system, 400 indoor
units, and 400 outdoor units can be controlled. units, and 100 outdoor units can be controlled.
• In addition to air conditioning precision control function, • In addition to air conditioning precision control function, a
central remote control, electricity charge calculation, schedule variety of management software is available as an option
management, and energy saving functions are strengthened to give customers a wide range of choice.
and building manager and owner needs are met.
VENTILATION
261
VENTILATION
Functions Summary
System controller System controller lite
262
Personal Computer System Requirements
The required PC specifications are shown in the following table.
Graphic
Microsoft® DirectX® 9.0c compatible
accelerator
Software Adobe® Reader® 9.0 or later
• Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.)
Packing List
For System controller For System controller Lite
VENTILATION
Option Option
Type
System System
Controller Energy Controller Lite Electricity charge
Remote access Energy saving Central Control
manager apportionment
Model name UTY-APGXZ1 UTY-PEGXZ1 UTY-ALGXZ1 UTY-PLGXR2 UTY-PLGXA2 UTY-PLGXE2 UTY-PLGXX2
WHITE-USB-KEY 1 1 1 1 1 1 1
*1: Software protection key to be inserted in a USB slot running System Controller or System Controller Lite.
System Controller or System Controller Lite may only run on a PC with WHITE-USB-KEY. However, WHITE-USB-KEY is not required for remote VRF Explorer software.
263
Notice for specifications
I.U. = Indoor Unit O.U. = Outdoor Unit Qu = Quiet * = Not decided yet
• Specifications and design are subject to change without notice for future improvement.
• For further details, please check with our authorised dealer.
• Cooling/Heating capacities are based on the following conditions.
Distributed by: