VENTILATION

Residential, Commercial & Light Commercial

VENTILATION
VENTILATION Lineup

228 Energy Recovery Ventilator


232 DX-Kit for Air Handling Application
• for VRF Outdoor Unit
234 DX-Kit for Air Handling Application
• for Single Split Outdoor Unit
236 AIR HANDLING UNIT
Effective heat exchange and simultaneous
fresh air ventilation
High Efficiency and low noise levels are
achieved by using a highly efficient heat
exchange process. A comfortable air
conditioned space is achieved by conveniently
selecting whether to use heat exchange or
normal ventilation setting, according to the
requirements of the conditioned space.

Lineup
Airflow rate (m3/h) 250 350 500 800 1000

VENTILATION
Energy Recovery
Ventilator
UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100C

Connectable capacity class (kW) 5.0 6.3 8.0 10.0 12.5 14.0 20.0 25.0 40.0 50.0

DX-Kit
for Air Handling Applications
for VRF Outdoor Unit
EEV unit Control unit EEV unit Control unit EEV unit Control unit EEV unit Control unit
UTP-VX30A UTY-VDGX UTP-VX60A UTY-VDGX UTP-VX90A UTY-VDGX UTP-VX90A × 2 UTY-VDGX

Connectable capacity class (kW) 3.5 - 22.0

DX-Kit
for Air Handling Applications
for Single Split Outdoor Unit
UTY-XDZXUK

Connectable capacity class (kW) 25 - 96

Air Handling Unit NEW

AHYA / AHYB / AHYC / AHYD / AHYE


VENTILATION

Energy Recovery
Ventilator

Energy recovery ventilator unit offers maximum comfort and


greater energy savings.

Heat exchange ventilation and normal ventilation Outside air


Exhaust air
Heat exchange ventilation
When a room is cooled or heated, the exhausted cooling / heating energy is
recovered by heat-exchange ventilation.
Normal ventilation Supply air
Su
Room air
The operation is used during periods when the room space requires no cooling
or heating effect, i.e. when there is minimal temperature difference between the Heat exchanger
indoor and outdoor environments.

Energy efficiency and ecology


Energy consumption is dramatically reduced by using a counter-flow heat-
exchange element. Air conditioning load is reduced by approximately 20%,
Adopts a highly efficient
resulting in significant energy savings. Recovers up to 77% of the heat in the
counter-flow heat exchange
outgoing air.
element

Features of heat exchange element


With the cross-flow element, air moves in a straight line across the element. With
the counter-flow element, air flows through the element for a longer time (longer
distance), so the heat-exchange effect improved.
Other element Fujitsu element
(Cross-flow element) (Counter-flow element)

Quiet operation Extended range of an external static


Significantly reducing low pressure loss and pressure
noise allows low-noise operation. 25.5dB
(UTZ-BD035C)
An external static pressure is improved by adopting a powerful fan
motor. This allows for application in a wide variety building.

Slim shape and easier Height Height

installation 270 mmm


UTZ-BD025C
388 mm
UTZ-BD080C/BD100C
U
Counter-flow heat exchange element used for
reduced noise and slimmer, more compact Height
body shape.
317 mm
UTZ-BD035C/BD050C

228
Room air Supply air Room air
Inspection
cover
Reverse mountable direct air supply / exhaust system Straight
Reverse
mounted
unit unit
Adoption of straight air supply / exhaust system: Duct design is simplified because Inspection
the air supply / exhaust ducts are straight. hatch
Since each unit can be mounted in reverse position, only one inspection hole is
needed for two units: Two units can share one inspection hole so duct work is
Exhaust air Outside air Exhaust air
easier and more flexible.

Simple remote operation


Easy operation by connecting a liquid crystal switch

• POWER ON/OFF • Air volume High/Low • Heat exchange/Normal Ventilation


• ON/OFF Timer • Clean filter display

Model : UTZ-BD025C / UTZ-BD035C / UTZ-BD050C / UTZ-BD080C / UTZ-BD100C

UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100C

Specifications

250 m3/h 350 m3/h 500 m3/h 800 m3/h 1000 m3/h
Model No. UTZBD025C UTZBD035C UTZBD050C UTZBD080C UTZBD100C
Power source 220 - 240V, 50Hz
Input power (Extra high)/High/Low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
(Extra high)/High/Low
I/s 69 / 69 / 52 97 / 97 / 66 138 / 138 / 122 222 / 222 / 175 277 / 277 / 194
Heat Exchange
Ventilation

External static pressure (Extra high)/High/Low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
Temperature Exchange
(Extra high)/High/Low % 75 / 75 / 77 75 / 75 / 78 75 / 75 / 76 75 / 75 / 76 75 / 75 / 79
Energy Exchange
(Extra high)/High/Low % 63 / 63 / 65 66 / 66 / 71 62 / 62 / 64 65 / 65 / 68 65 / 65 / 70

VENTILATION
Energy Exchange
(Extra high)/High/Low % 70 / 70 / 72 69 / 69 / 73 67 / 67 / 69 71 / 71 / 74 71 / 71 / 76
Sound pressure level (Extra high)/High/Low dB* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 37.5 / 35.5 / 32.5 37.5 / 37 / 34.5 38.5 / 37.5 / 34.5
Input power (Extra high)/High/Low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
Ventilation

m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
Normal

(Extra high)/High/Low
I/s 69 / 69 / 52 97 / 97 / 66 138 / 138 / 122 222 / 222 / 175 277 / 277 / 194
External static pressure (Extra high)/High/Low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
Sound pressure level (Extra high)/High/Low dB* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 38.5 / 38 / 32.5 37.5 / 37 / 34.5 40.5 / 39.5 / 36.5
Dimensions W×D×H mm 882 x 599 x 270 1050 x 804 x 317 1090 x 904 x 317 1322 x 884 x 388 1322 x 1134 x 388
Weight kg 29 49 57 71 83
Outlet duct diameter mm 150 150 200 250 250
Operation range °C -10 to 40 -10 to 40 -10 to 40 -10 to 40 -10 to 40
Maximum humidity % 85 85 85 85 85

* The noise level must be measured 1.5 m below the centre of the unit.

Dimensions
(Unit : mm)

UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100B


A 810 978 1,018 1,250 1,250
B 599 804 904 884 1,134
C 315 580 640 428 678
D 142 112 132 228 228
E 600 600 600 600 600
F 655 860 960 940 1,190
G 19 19 19 19 19
H 270 317 317 388 388
I 135 159 159 194 194
J 159 182 182 218 218
Maintenance opening K 882 1,050 1,090 1,322 1,322
Maintenance space L 414 470 470 612 612
M 95 70 70 85 85
N Ø164 Ø164 Ø210 Ø258 Ø258
O Ø144 Ø144 Ø194 Ø242 Ø242

229
VENTILATION

Energy
Recovery
Ventilator
Options
Energy recovery ventilator unit offers
maximum comfort and greater energy
savings.

ERV RELAY

This accessory will allow an Energy Recovery Ventilator unit to start &
stop in unison with the connected indoor unit
(There will be no control over on / off, fan speed or damper bypass)

Model Name UTY-ERVRELAY1


Power source 208 - 240V, 50Hz, Single Phase
Dimensions (H x W x D) mm
Weight g TBC

230
Hard wired Control Interface
In order to use a Fujitsu hard-wired controller with the ERV units an interface
is required

The UTIERV2 interface provides the following features:-

• UTI-ERV2 interrface is supplied with an outside air intake duct sensor for control of the ERV
bypass damper e.g. heat recovery or "free cooling" bypass mode
• Dry contact terminals for remote on/off e.g. from BMS
• Allows the use of a Fujitsu UTY-RNNYM* hard wired controller which has the following features:
• Allows ERV fan speed selection from the remote controller
• Controller has an integral 7 day programmable time clock
• Controller has temperature selection for auto control of the damper
• Filter clean indicator facility
• Manual or Auto control of the bypass damper

Please refer to the UTI-ERV installation


Please refer to ERV"
manual for the full wiring diagram
DO NOT use the above diagram this is
for illustrative purposes only

VENTILATION
Description of the buttons on UTY-RNNYM remote 1. Start / Stop
2. Set Temperature
3. Master Control
4. Fan Control
5. ERV on/off
6. Timer mode (clock adjust)
7. Day (day off)
8. Set Back
9. Set Time
10. Delete
11. Set
12. N/A
13. N/A
14. Filter Button
15. Operation Lamp
16. Timer & Clock Display
17. Operation Mode Display
18. Fan Speed Display
19. Operation Lock Display
20. Temperature Display
21. Function Display
Delete
Set Button

Model Name UTIERV2 UTYRNNYM


Power source 208 - 240V, 50/60Hz, Single Phase From UTIERV2
Power Consumption W 6.5 -
Dimensions (H x W x D) mm 67 × 288 × 211 120 × 120 × 18
Weight g 1,500 160

*UTYRNNYM to be ordered seperately

231
VENTILATION

DX-Kit
for Air Handling Application
for VRF Outdoor Unit

These kits enable other manufacturers air handling units (AHU) and fan coil units (FCU) to be incorporated into a Fujitsu VRF system or, be
connected to a dedicated Fujitsu VRF outdoor unit as a 1:1 system to control outside air ventilation (AHU) or room temperature (FCU).

Multiple temperature sensors optimally control


Arrangement as part of a VRF system
the air handling unit and fan coil unit.
Transmission line
AHU Thermistor Indoor
unit
When connecting to an air handling unit,
the supply air temperature is controlled
DX-Kit by the discharge sensor. VRF system

Air Handling
Unit
FCU
Control unit
When connecting to a fan coil unit, the
room temperature is controlled by the EEV unit
return air temperature sensor. DX-Kit
DX-Kit Thermistor Wired R.C.
Thermistor

Supports a wide range of capacity classes EEV unit

• 2 EEV units can be connected in parallel and up to 20 HP (50 kW)


Piping
large capacity units. (Separation Tube of UTP-LX180A is required.) EEV unit
AHU or FCU
• Connectable capacity range: 5 kW to 50 kW (40 – 50 kW class)

Wiring Control unit

A variety of controls to match the application


Central control using our VRF controllers or central management Central control from external controllers
controllers

Thermistor
Transmission line
External I/O DDC*
External I/O
Transmission line
Interface Thermistor
(Option) AHU or FCU
DX-Kit DX-Kit
AHU or FCU 3rd party
VRF Modbus External I/O Controller *DDC=Direct Digital Controller
Controller network

232
Functions Summary Inputs Outputs MODBUS® Control
• ON/OFF • ON/OFF indication Possible to control via a
• Setting temperature • Fan ON/OFF indication MODBUS enabled BMS by
• Capacity demand • Thermo ON/OFF indication using optional interface.
• Heating / Cooling operation • Defrost indication
mode • Fault indication
• Fault information

Installation Limitation Connectable capacity


• Connectable VRF Series: All VRF Series • Single connection • Mixed connection
• Connectable DX-Kit system capacity range: 50 to
100% of the outdoor unit capacity
• Connectable DX-Kit system capacity range with DX-Kit DX-Kit
indoor units: 30% or less of the outdoor unit
capacity
• Max. wiring length from control unit: 10 m
Air Handling Unit Air Handling Unit
• Max. piping length between EEV unit and indoor
unit: 5 m 50% – 100% of outdoor unit capacity Within 30% of total capacity
• Outdoor installation: Control unit (IP54 class) and
EEV unit can be installed at an outdoor space. 50% – 100% of outdoor unit capacity

Piping and wiring length


For 2 EEV units connection (option)
Separation Tube: UTP-LX180A Air Handling Unit
EEV unit

Max. piping length 5 m Control unit


Max. wiring length 10 m

Max. wiring length 15 m

VENTILATION
Control unit: UTY-VDGX
EEV unit: UTP-VX30A / UTP-VX60A / UTP-VX90A

EEV unit EEV unit EEV unit Control unit


UTP-VX30A UTP-VX60A UTP-VX90A UTY-VDGX

Specifications
Connectable Capacity class 5.0 kW 6.3 kW 8.0 kW 10.0 kW 12.5 kW 14.0 kW 20.0 kW 25.0 kW 40.0 kW 50.0 kW
Cooling 5.6 6.3 8.0 10.0 12.5 14.0 22.4 25.0 40.0 50.4
Capacity kW
Heating 6.3 7.1 9.0 11.2 14.0 16.0 25.0 28.0 45.0 56.5

Control unit UTY-VDGX


Power source V/Ø/Hz 230/1/50
Dimensions (H × W × D) mm 400 × 400 × 120

EEV unit UTP-VX30A UTP-VX60A UTP-VX90A UTP-VX90A×2


Connection pipe diameter (Liquid) Ø9.53 Ø12.70 Ø12.70 Ø12.70
mm
Dimensions (H × W × D) 160 × 220 × 90
Note: Specifications are based on the following conditions.
Cooling: Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating: Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length: 7.5 m Voltage : 230 [V].

233
VENTILATION

DX-Kit
for Air Handling Application
for Single Split Outdoor Unit

This kit enables other manufacturers air handling units (AHU) and fan coil units
(FCU) to be incorporated into a Fujitsu General Split outdoor unit.

Flexible connectivity Air Handling


Unit
DX-Kit
This kit is a control unit to allow connection to third party
manufacturer equipment. Fujitsu General single split
outdoor units can be used with this control unit, creating
an ideal solution when a unique air handling unit is
Wiring
required.
Thermistor
wiring

Outdoor unit
Piping

Supports a wide range of capacity class


Connectable large capacity range: 3.5 kW ~ 22.0 kW
(Nominal)

3.5 kW 22.0 kW

Operation from anywhere on your


mobile device
Internet
Available to use operation and management from remote
control such as Smartphones and Tablets Tablet

DX-Kit

Smartphone

234
Functions Summary Inputs Outputs Wireless LAN Control
• ON/OFF • Status of Compressor, Wireless LAN control with cloud
• Heating/Cooling operation Defrost, Error (Potential free connectivity enables safe remote
mode relays) monitoring and control from
• Capacity demand (analogue • LED status indication anywhere.
0-10 V)
• Heat exchanger temperature

Easy installation
• Simple installation through compact DIN rail
mountable enclosure
• No need for expansion devise
• No separate external power required

VENTILATION
Model: UTY-XDZXUK

Specifications
BTU 12 14 18 24 30 36 45 54 60 72 90
Cooling 3.5 4.3 5.2 6.8 8.5 9.4 12.1 13.3 15.0 19.0 22.0
Capacity (Nominal) kW
Heating 4.1 5.0 6.0 7.8 10.0 10.8 13.3 15.8 18.0 22.4 27.0

Model No. UTY-XDZXUK


Power source V/Ø/Hz 230/1/50 (fed from outdoor unit)
Dimensions (H × W × D) mm 225 x 155 x 90
Weight Kg 0.855
Note: Specifications are based on the following conditions.
Cooling: Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating: Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length: 5.0 m Voltage : 230 [V].

235
VENTILATION

Light Commercial & Commercial

AIR HANDLING UNIT


238 System Overview
240 AIRSTAGETM Lineup
242 Air Handling Units Overview
244 Features
Structure
Filtration
Thermal Exchange Sections
Fan Section
Humidifier
Heat Recovery Section
250 Dimensions
253 Loose Accessories
254 Total Pressure Drops Calculation
255 Fan Characteristic Curves
258 Specifications
260 Control System
– AHU Controller
– System Controller, System Controller Lite

236
237
VENTILATION
VENTILATION

System Overview
AHU CONTROLLER

The Air handling applications for the AIRSTAGE™ system is the


Fujitsu general solution to the most demanding installations,
where energy efficiency meets with the highest comfort.

The system is composed of AIRSTAGE™ outdoor units from


10 to 54 HP and Air handling unit for civil and industrial
buildings for thermo-ventilation and air conditioning
purposes, covering air flow ranges from 4,300 to 18,100 m3/h
and cooling capacities from 25 to 96 kW. SYSTEM CONTROLLER

Controller line
VRF
Controller line

Transmission line

Transmission line

Piping line

- For AHU control: AHU controller (Only For AHU)


- For mixed connection control: System controller, or 3rd party controller with Modbus convertor

238
The Advantages of the
NEW
System

AHU Full comfort

VENTILATION
The system offers full comfort and air quality in the
buildings providing clean treated air thanks to the
AIR HANDLING UNIT advanced filtration and balanced temperature.

Easy design and installation


The system is simple design and installation. No additional
external kit is required as the Air Handling Unit includes
DX-kit (Expansion valve and control PCB) AHU model
selection is easy by using Selection Software.

Total solution concept


Integrating an Air Handling Unit into the total building
climate system simplifies both design and installation
procedures based on a single common technology. From
project follow-up to installation, commissioning and
maintenance, all procedures are simplified. There is a
requirement for not more than one installer.

239
VENTILATION

AIRSTAGE™ Lineup
Fujitsu General provides multi air conditioning systems
for buildings AIRSTAGE™ Series matched to the size and
application of the property.

Capacity (kW) 28.0 33.5 40.0 45.0 50.4 55.9 61.5 67.0 73.5 78.5 85.0
HP 10 12 14 16 18 20 22 24 26 28 30

J-IVL Series

AJY090 AJY108 AJY126 AJY144 AJY162


LELBH LELBH LELBH LELBH LELBH

Space
Saving
V-III Series Heat Pump

AJY090 AJY108 AJY126 AJY144 AJY162 AJY180 AJY198 AJY216 AJY234 AJY252 AJY270
Set Model LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH

Energy
(IÀFLHQF\

AJY144 AJY162 AJY180 AJY216 AJY234 AJY252 AJY270


Set Model LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH

for Small Office

Fujitsu General provides air conditioning systems


for a wide range of applications from small office
buildings and stores to large houses.

240
90.0 95.0 100.5 107.0 112.0 118.5 123.5 130.0 135.0 140.0 145.0 150.0
32 34 36 38 40 42 44 46 48 50 52 54

AJY288 AJY306 AJY324 AJY342 AJY360 AJY378 AJY396 AJY414 AJY432 AJY450 AJY468 AJY486
LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH

AJY288 AJY306 AJY324 AJY342 AJY360 AJY378 AJY396 AJY414


LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH

VENTILATION

for Large Office

Smart and cutting edge design. Extensive line-up


from 10 HP to 54 HP in 2 HP increments. Connectable
indoor unit capacity ratio up to 100%

241
VENTILATION

Air Handling Units Overview


AHU is the range of Air Handling Units for civil and industrial
buildings for thermo-ventilation and air conditioning
purposes, designed to be connected with AIRSTAGE™ Series
Outdoor units.
Units are available in different models and several additional
modular sections to meet all installation needs, with air flow
ranges varying from 4,300 to 18,100m³/h and covering a
cooling capacity from 25 to 96kW.

AHU is made of extruded aluminium profiles and nylon Fan section


angle bars. The “sandwich-type” double-skin panels (50 mm
thick) with galvanised sheets, externally pre-painted, and
thermal insulation in high density polyurethane foam are
fastened on the units by means of an aluminium snap-in
locking system.

AHU fan section is equipped with EC Inverter Plug-Fans and


is provided with Automatic Regulation Control Systems for
Constant Air Flow and Constant Available Static Pressure. An
electronic device with pressure sensors on the system and
control sensors on EC Plug-Fans adjust the flow rate and the
available static pressure to keep the air flow constant.

Air inlet
sections

5 configurations are
Available
Configuration A
In line with Front Damper
For fresh air operation up to 100% external air

Configuration B
In line with Top Inlet Damper
For fresh air operation up to 100% external air

Configuration C
In line with Inlet Mixing Box
For fresh air operation up to 20% external air

Configuration D
Double Deck with Cross-Flow Heat
Exchanger
Configuration E
Double Deck with Thermal Wheel

Filters section

242
Coil section including built-in
expansion valve with PCB Electrical heating
section
control

Fan section

VENTILATION

3KRWR&RQÀJXUDWLRQ(

+XPLGLÀFDWLRQ
sections

Heat recovery
&URVVÁRZW\SH

Sound attenutor
sections
Heat recoveryy
Thermal wheel type
e

243
VENTILATION

Feature

3KRWR&RQÀJXUDWLRQ&

Structure
Section of extruded profile 62 × 62 mm (SNAP-IN system)

• The Airr Handling Units are manufactured with bearing framework and sandwich paneling.
• The frame
ame is made of extruded anticorodal aluminium alloy profiles of AlMgSi 0,5- UNI 9006/1
9006/ type.

Mechanical characteristics of extruded aluminium alloy


Unitary load
6SHFLÀFZHLJKW Yielding load Stretch Brinell hardness
Denomination of traction break
(kg/dm3) S (0,2) (kg/mm2) (%) (kg/mm2)
R (kg/mm2)

ANTICORODAL
050 UNI 9006/1
2,70 20 ÷ 23 16 ÷ 20 12 ÷ 15 60 ÷ 70
EX UNI 3569 (6060)
ISO = Al Mg Si 0.5

Profile
• The exclusive bearing structure made by Fujitsu General, having actual dimension of 62 x 62 mm, uses
the lock panel system in aluminium (SNAP-IN system). This system permits to reach paneling tightnesses
beyond 2500 Pa (10 in WG), because of the homogeneity of the pressure over the paneling perimeter, not
achievable with the traditional system (selfdrilling screw fastening). This profile doesn’t require the aid of
internal and external screws, providing a more solid and aesthetically pleasing appearance.
• Because of the dimensions of the profile, the used panel has actual dimensions of 50 mm.
• The profile hasn’t got external sharp edges, as foreseen by the safety and accident-prevention rules in force.
• Air Handling Units are certified for the highest performance standards.

E r P LOT6 - 2018
• The EUROVENT certification on Fujitsu General units proves the reliability and correctness of declared
performance data and features.
• Fujitsu General units and all internal components are compliant to ErP EcoDesign 2018 LOT6 Regulation.
• The compliance of Fujitsu General units to UNI EN 1886 European Regulation about structure thermal and
mechanical performance is also certified by Eurovent.

(Unit : mm)
77
62 15
62
77
15

244
Panelling
The panelling is double skin sandwich type made of galvanised
sheet, with polyurethane foam insulation of minimum density 45
kg/m3, actual thickness: -50 mm Cold-rolled steel
Hot galvanising
Panels are made as follows:
Inner skin: Hot dipped galvanised sheet (galvanisation not less Phosphate coating
than 140 g/m2), 5/10 mm thick. Primer or back coat
Insulation: Rigid polyurethane foam minimum density 45 kg/m3, Finishing paint
thermal conductivity 0,018 ÷ 0,024 w/m2 °c.
Outer skin: Hot dipped pre-painted galvanised sheet
(galvanisation not less than 140 g/m2), 6/10 mm thick.

PRE-PAINTED GALVANISED STEEL SHEET

Steel Sheet Features Baseframe

Hot dipped galvanised steel sheet type Fe P02 GZ 140 UNI En The bearing baseframe is made of galvanised steel with pressure
10142 with galvanisation not less than 140 g/m2. The thickness is bent, bolted or welded profile, according to the configuration of

VENTILATION
6/10 mm. the unit.
Pre-painted steel sheet 6/10 mm thick with base support made It is arranged for the sections lifting and suitable for water piping
of hot dipped galvanised steel (galvanisation not less than 140 passage and drain.
g/m2) EURONORM 142-79 and coating, colour white-grey for a Perimeter baseframes heights and profiles are dimensioned as
special resistance to weathering. The protective system consists of follows: H = 100 mm with bolted C profile for all units
a dry film of 25 μm on the exposed skin and of a dry film of 5 μm
The baseframes of all the above solutions are made of galvanised
on the non-exposed skin.
steel sheet with minimum thickness 2.0 mm.
Hardness of film: F on the Koh - i - Noor’s scale.
Other chemical-physical characteristics:
• Resistance beyond 250 h in salty mist (ECCA T8)
• Resistance beyond 1000 h in high humidity conditions (ASTM D
714)
• Film resistance to the cleaving and adhesion after bending
(ECCA T7).
A self-adhesive PVC film is laid on the steel sheet exposed surface
in order to avoid damages during the manufacturing procedures
SECTION VIEW.
and transport. The baseframe is flush with the panelling

Covering Roof (TT - Accessory)


•All units that must be positioned outside or generally speaking are exposed to the weather may be equipped with a hot galvanised steel sheet
roof (galvanisation not less than 140 g/m2) as accessory element.
•The roof overhang with regard to the unit outer dimensions is of about 100 mm.
•All roof corners are equipped with accident prevention corners protections.

245
VENTILATION

Filtration
Plate Filters COARSE 55%

Plate filters filter the air at a low and medium


efficiency.
• Plate filters are commonly used as prefilters in order to keep a longer efficiency of
filters installed downstream.
• Plate filters are installed on guides fastened inside the unit. In this case the air by-
pass is minimum.

Plate filters are highly used because of the following


features
• Easy removal
• Easy availability on spare parts market
• Regenerability (they can be washed with warm water and soap or common
domestic detergents).

Plate filters are made of


• Galvanised steel sheet frame 48 mm th.
• Support containing net made of galvanised electrowelded wire
• Filtering material made of synthetic fiber with filtration efficiency COARSE 55%.

Filtration
Bag Filters ePM1 50%

Bag filters have the characteristic of giving a wide


filtering area thanks to their bag shape and therefore
they highly reduce the crossing air speed.
The bags are installed on galvanised slides for side extraction. This filtering section
includes the access door.

N.B. ePM1 50% bag filters are mandatory Soft bag filter features
for ECODESIGN ErP 2016 compliance
• Efficiency, ePM1 50%
• Depth 287 mm
• Fiberglass filtering stuff
• Galvanised steel sheet frame
• 80% of the material is recyclable
• Limit relative humidity 100%.

246
Thermal Exchange Sections
DX Coil

The section consists of


• DX coil with copper tubes and aluminium fins, specifically designed to guarantee
an high thermal exchange and an excellent ratio between sensible and latent
heat;
• One distributor and one electronic expansion valve for each circuit connected
to its control PCB, which is located in close proximity to avoid every possible
interference, immunity and electromagnetic disturbance problems;
• Temperature probes installed at the front, at the rear and in the middle of the coil
provide the data to the control PCB, which consequently determines the opening of
the electronic expansion valve, depending on the work point and the set point;
On multi-module units the cooling circuits are interlaced to guarantee a full
exploitation of the exchange surface and air treated uniformity also at partial loads.
The section includes the PCB control.

VENTILATION
Thermal Exchange Sections
Electrical Heating

Electrical heating section is used for the execution of


heating and post-heating treatment

They are manufactured as follows


• galvanised steel sheet flanged containing frame
• finned steel tubular heaters on base insulators
• safety fix thermostat with manual reset
• electrical heating is foreseen for 3-Stage 400V/3P/50 up to 36 kW capacity.

247
VENTILATION

Fan Section
EC Inverter Plug-Fan

The fan section is equipped with EC Inverter Plug-Fan.


• The EC Inverter Plug-Fans are managed by an electronic control adjusting fans rotational
speed to adapt air flow and static pressure to the system capacity. They supply a variable air
flow according to the requested thermal load, providing important benefits in terms of energy
consumption and low noise operation especially when the unit is operating at partial load.
• The EC Inverter Plug-Fans can be set to different working conditions, according to the unit
needs, directly on site through the control panel installed on the Electrical Board section.
• Compared to traditional Plug-Fans, thanks to EC Inverter technology the overall efficiency
and acoustic behaviour of the fans has been significantly improved. The blade geometry with
a diagonal trailing edge has positive effects on the aerodynamic performance and on the
running smoothness of the fans. The same is true for the implemented nozzle contour.
• The overall dimension of the section can be kept at minimum thanks to the fan dimension:
the EC motor is integrated directly in the impeller. A belt drive between the motor and the fan,
which is commonly used otherwise, is not necessary. This reduces the required installation
volume and the associated installation effort.
• The EC Plug-Fans significantly exceed the ErP 2015 norm and the requirements of energy
efficiency class A+ stated in German manufacturer’s association RLT Directive 01, “General
Requirements for Ventilation and Air-conditioning Devices”.
• AHU fan section equipped with EC Inverter Plug-Fans is provided with the Automatic
Regulation Control Systems for Constant Air Flow and Constant Available Static Pressure. An
electronic device with pressure sensors on the system and control sensors on EC Plug-Fans
adjust the flow rate and the available static pressure to keep the air flow constant.

Humidifier

Electrode humidifiers specifically designed for installation


inside air handling units.
• The humidifier is constituted by two parts connected together electrically: the hydraulic part
and the control unit based on a microprocessor board. The hydraulic part is completely inserted
into the AHU, lying on the condensate drain tank immediately downstream of the cooling coil.
• The control is fully integrated in the microprocessor installed aboard the AHU.
• The hydraulic boiler is made up of plastic polypropylene “channel” having a section of 33 cm
x 16 cm height, and having a length proportional to the width of the AHU. Inside the boiler
are arranged longitudinally the stainless steel electrodes, connected to the power supply
phases and easily removable The lid is made of plastic sections with slope, so as to allow any
condensation that falls by gravity into the boiler in order to avoid power losses.
• Between the plastic sections is obtained a narrow longitudinal slot which allows the output of
the steam produced, that meets the air for the whole length of the AHU section.
• This solution prevents the formation of condensate in the pipes and also prevents any increase
in steam pressure in the boiler due to blockages in the pipes conveying steam.

On one side of the kettle (the easiest to access once installed)


you have the body of hydraulic management of the system
• Maximum water level sensor
• Draining bloc the draining bloc has been specially designed to empty the tank from water and
limestone pieces without having to block and having to be able to work without pressure.
A electronic rotation sensor, rigidly grafted on the pivot motor, communicating with the
microprocessor which manage the correct operation and shown in the display any faults that
may appear.

248
Heat Recovery Section
Cross Flow Heat Recovery

The recovery unit efficiency has values up to 85%.


• The fixed plates static recovery units are air to air type, without moving parts,
therefore working in a reliable and safe way. The air movement is in a crossed flow
with heat transfer directly from higher temperature flow to the lower temperature
one. The recovery unit efficiency has values up to 85%.
• This type of heat exchanger is made of pressed aluminium sheets, housed in a
variable spacing depending on the use type.
• Sealings are made along the edges in order to prevent contamination on renewal
air from polluting agents contained in exhaust air.

The normal supply foresees


• Recovery units with aluminium fins
• Cell prefilters COARSE 55% type (85% eff.) on fresh air side
• Galvanised steel sheet drain pan to collect possible condensation.

Heat Recovery Section


Thermal Wheel Recovery Units

VENTILATION
The working principle is the following
• The exhaust air crosses half circular rotor sector and gives part of its heat to the
metallic mass. This, slowly wheeling, is invested from cold renewal air crossing
in counterflow the other half of the exchanger, taking the heat given from the
exhaust air. When the rotor is hygroscopic type, also humidity contained into the
exhaust air will be partially transferred to the renewal air.
• The words “warm air” and “cold air” of the above description are valid for winter
working cycle; in summer cycle the functions of transfer and absorption of heat and
humidity are evidently inverted.

Usually these type of recovery units are made as follows


• aluminium rotor
• galvanised steel sheet frame
• constant speed electric gearmotor

249
VENTILATION

Dimensions

Configurations A

Electrical

1
Box

CPS0 PPTSF DX SV

Electrical

2
Box

CPS0 PPTSF DX PEH SV

Electrical
Box

3
CPS0 PPTSF DX PUV SV

Electrical
Box

4
CPS0 PPTSF DX PUV PEH SV

H W L L (with silencer)
Model name Config. kg
(mm) (mm) (mm) (mm)

AHYA025GWAA 1 1,064 1,154 2,619 611 3,529


AHYA025GWAB 2 1,064 1,154 3,109 679 4,019
AHYA025GWAC 3 1,064 1,154 2,619 629 3,529
AHYA025GWAD 4 1,064 1,154 3,109 697 4,019
AHYA040GWAA 1 1,199 1,354 2,749 844 3,659
AHYA040GWAB 2 1,199 1,354 3,319 931 4,229
AHYA040GWAC 3 1,199 1,354 2,749 865 3,659
AHYA040GWAD 4 1,199 1,354 3,319 952 4,229
AHYA048GWAA 1 1,309 1,574 2,749 921 3,659
AHYA048GWAB 2 1,309 1,574 3,319 1,023 4,229
AHYA048GWAC 3 1,309 1,574 2,749 944 3,659
AHYA048GWAD 4 1,309 1,574 3,319 1,046 4,229
AHYA080GWAA 1 1,544 2,074 3,189 1,542 4,099
AHYA080GWAB 2 1,544 2,074 3,839 1,701 4,749
AHYA080GWAC 3 1,544 2,074 3,189 1,570 4,099
AHYA080GWAD 4 1,544 2,074 3,839 1,729 4,749
AHYA096GWAA 1 1,789 2,250 3,189 1,691 4,099
AHYA096GWAB 2 1,789 2,250 3,839 1,869 4,749
AHYA096GWAC 3 1,789 2,250 3,189 1,724 4,099
AHYA096GWAD 4 1,789 2,250 3,839 1,899 4,749

250
Configurations B Configurations C

Electrical
Electrical

1 Box

1 Box

CPS1 PPTSF DX SV CPS2 PPTSF DX SV

Electrical
Electrical

2 2
Box
Box

CPS1 PPTSF DX PEH SV CPS2 PPTSF DX PEH SV

Electrical
Electrical

3 3
Box
Box

CPS1 PPTSF DX PUV SV CPS2 PPTSF DX PUV SV

Electrical
Electrical
Box

4 4
Box

CPS1 PPTSF DX PUV PEH SV CPS2 PPTSF DX PUV PEH SV

VENTILATION
H W L L (with silencer) L (with silencer)
Model name Config. kg Model name Config. H (mm) W (mm) L (mm) kg
(mm) (mm) (mm) (mm) (mm)

AHYB025GWAA 1 1,179 1,154 2,854 628 3,764 AHYC025GWAA 1 1,179 1,154 2,969 650 3,879
AHYB025GWAB 2 1,179 1,154 3,344 696 4,254 AHYC025GWAB 2 1,179 1,154 3,459 718 4,369
AHYB025GWAC 3 1,179 1,154 2,854 646 3,764 AHYC025GWAC 3 1,179 1,154 2,969 668 3,879
AHYB025GWAD 4 1,179 1,154 3,344 714 4,254 AHYC025GWAD 4 1,179 1,154 3,459 736 4,369
AHYB040GWAA 1 1,314 1,354 3,084 873 3,994 AHYC040GWAA 1 1,314 1,354 3,199 899 4,109
AHYB040GWAB 2 1,314 1,354 3,654 960 4,564 AHYC040GWAB 2 1,314 1,354 3,769 986 4,679
AHYB040GWAC 3 1,314 1,354 3,084 894 3,994 AHYC040GWAC 3 1,314 1,354 3,199 920 4,109
AHYB040GWAD 4 1,314 1,354 3,654 981 4,564 AHYC040GWAD 4 1,314 1,354 3,769 1,007 4,679
AHYB048GWAA 1 1,424 1,574 3,084 953 3,994 AHYC048GWAA 1 1,424 1,574 3,199 980 4,109
AHYB048GWAB 2 1,424 1,574 3,654 1,055 4,564 AHYC048GWAB 2 1,424 1,574 3,769 1,082 4,679
AHYB048GWAC 3 1,424 1,574 3,084 976 3,994 AHYC048GWAC 3 1,424 1,574 3,199 1,003 4,109
AHYB048GWAD 4 1,424 1,574 3,654 1,078 4,564 AHYC048GWAD 4 1,424 1,574 3,769 1,105 4,679
AHYB080GWAA 1 1,659 2,074 3,624 1,591 4,534 AHYC080GWAA 1 1,659 2,074 3,739 1,624 4,649
AHYB080GWAB 2 1,659 2,074 4,274 1,749 5,184 AHYC080GWAB 2 1,659 2,074 4,389 1,782 5,299
AHYB080GWAC 3 1,659 2,074 3,624 1,619 4,534 AHYC080GWAC 3 1,659 2,074 3,739 1,652 4,649
AHYB080GWAD 4 1,659 2,074 4,274 1,777 5,184 AHYC080GWAD 4 1,659 2,074 4,389 1,810 5,299
AHYB096GWAA 1 1,904 2,250 3,724 1,760 4,634 AHYC096GWAA 1 1,904 2,250 3,839 1,799 4,749
AHYB096GWAB 2 1,904 2,250 4,374 1,936 5,284 AHYC096GWAB 2 1,904 2,250 4,489 1,975 5,399
AHYB096GWAC 3 1,904 2,250 3,724 1,790 4,634 AHYC096GWAC 3 1,904 2,250 3,839 1,829 4,749
AHYB096GWAD 4 1,904 2,250 4,374 1,966 5,284 AHYC096GWAD 4 1,904 2,250 4,489 2,005 5,399

251
VENTILATION

Configurations D Configurations E

REC-FX SV PP CPS0 CPS0 REC-WH PPTSF

1 Electrical
Box
1 Electrical
Box

PPTSF DX SV CPS0 PPTSF REC-WH DX SV

REC-FX SV PP CPS0 CPS0 REC-WH PPTSF

2 Electrical
Box
2 Electrical
Box

PPTSF DX PEH SV CPS0 PPTSF REC-WH DX PEH SV

REC-FX SV PP CPS0 CPS0 REC-WH PPTSF

3 Electrical
Box
3 Electrical
Box

PPTSF DX PUV SV CPS0 PPTSF REC-WH DX PUV SV

REC-FX SV PP CPS0 CPS0 REC-WH PPTSF

4 Electrical
4 Electrical
Box Box

PPTSF DX PUV PEH SV CPS0 PPTSF REC-WH DX PUV PEH SV

L (with silencer) L (with silencer)


Model name Config. H (mm) W (mm) L (mm) kg Model name Config. H (mm) W (mm) L (mm) kg
(mm) (mm)
AHYD025GWAA 1 2028/1064 1424/1154 4,311 1,259 5,221 AHYE025GWAA 1 2028/1064 1429/1154 3,813 1,150 4,723
AHYD025GWAB 2 2028/1064 1424/1154 4,801 1,327 5,711 AHYE025GWAB 2 2028/1064 1429/1154 4,303 1,226 5,213
AHYD025GWAC 3 2028/1064 1424/1154 4,311 1,277 5,221 AHYE025GWAC 3 2028/1064 1429/1154 3,813 1,168 4,723
AHYD025GWAD 4 2028/1064 1424/1154 4,801 1,345 5,711 AHYE025GWAD 4 2028/1064 1429/1154 4,303 1,244 5,213
AHYD040GWAA 1 2298/1199 1574/1354 4,871 1,750 5,781 AHYE040GWAA 1 2298/1199 1729/1354 4,073 1,571 4,983
AHYD040GWAB 2 2298/1199 1574/1354 5,441 1,837 6,351 AHYE040GWAB 2 2298/1199 1729/1354 4,643 1,658 5,553
AHYD040GWAC 3 2298/1199 1574/1354 4,871 1,771 5,781 AHYE040GWAC 3 2298/1199 1729/1354 4,073 1,592 4,983
AHYD040GWAD 4 2298/1199 1574/1354 5,441 1,858 6,351 AHYE040GWAD 4 2298/1199 1729/1354 4,643 1,679 5,553
AHYD048GWAA 1 2518/1309 1824/1574 4,871 1,978 5,781 AHYE048GWAA 1 2518/1309 1829/1574 4,073 1,696 4,983
AHYD048GWAB 2 2518/1309 1824/1574 5,348 2,080 6,258 AHYE048GWAB 2 2518/1309 1829/1574 4,643 1,798 5,553
AHYD048GWAC 3 2518/1309 1824/1574 4,778 2,001 5,688 AHYE048GWAC 3 2518/1309 1829/1574 4,073 1,719 4,983
AHYD048GWAD 4 2518/1309 1824/1574 5,348 2,103 6,258 AHYE048GWAD 4 2518/1309 1829/1574 4,643 1,821 5,553
AHYD080GWAA 1 2988/1544 2,074 6,161 3,361 7,071 AHYE080GWAA 1 2988/1544 2374/2074 4,953 2,753 5,863
AHYD080GWAB 2 2988/1544 2,074 6,811 3,520 7,721 AHYE080GWAB 2 2988/1544 2374/2074 5,603 2,912 6,513
AHYD080GWAC 3 2988/1544 2,074 6,161 3,389 7,071 AHYE080GWAC 3 2988/1544 2374/2074 4,953 2,781 5,863
AHYD080GWAD 4 2988/1544 2,074 6,811 3,548 7,721 AHYE080GWAD 4 2988/1544 2374/2074 5,603 2,940 6,513
AHYD096GWAA 1 3478/1789 2,250 6,451 3,849 7,361 AHYE096GWAA 1 3478/1789 2582/2250 4,953 3,035 5,863
AHYD096GWAB 2 3478/1789 2,250 7,008 4,025 7,918 AHYE096GWAB 2 3478/1789 2582/2250 5,603 3,211 6,513
AHYD096GWAC 3 3478/1789 2,250 6,451 3,879 7,268 AHYE096GWAC 3 3478/1789 2582/2250 4,953 3,065 5,863
AHYD096GWAD 4 3478/1789 2,250 7,008 4,055 7,918 AHYE096GWAD 4 3478/1789 2582/2250 5,603 3,241 6,513

252
Silencer PI

Loose Accessories

VENTILATION
Galvanised metal sheet roof
All units that must be positioned outside or generally speaking
are exposed to the weather may be equipped with a hot-
galvanised metal sheet roof (galvanisation not less than 140 g/
Connectable AHU model name H (mm) L (mm) W (mm) Kg m2) an accessory element.
The roof overhang with regard to the unit outer dimensions is
AHY* 025GWA* 1064 910 1154 209 of about 100 mm. All roof corners are equipped with accident
AHY* 040GWA* 1199 910 1354 233
prevention protections.

AHY* 048GWA* 1309 910 1574 274

AHY* 080GWA* 1544 910 2074 280


Cold-rolled steel
AHY* 096GWA* 1789 910 2250 444
Hot galvanising
Phosphate coating
Primer or back coat
Finishing paint

253
VENTILATION

Total Pressure Drops Calculation

AHU units, being controlled by EC Inverter Plug-


Fans, can satisfy a high range of required air
flow rate and static pressure.
The EC Inverter Plug-Fans can be set to different working conditions,
according to the unit needs, directly on site through the control panel
installed on the Electrical Board section.

Procedure for selection


• Select the AHU model most suitable according the air volume.
• Check the air flow static pressure operating point on the curve of the
chosen fan by crossing the required air flow rate with the value of the
overall static pressure.
To calculate the total static pressure value refer to the Components
Pressure Drop table and add the net static pressure required for the
plant.

Components Pressure Drop table


PHE + COARSE COARSE COARSE
Inlet Inlet ePM1 50% Exhaust
COARSE dampers PHE + 55% filters Heat 55% filters Heat 55% filters
damper damper ePM1 50% filters damper Electrical
MIN Airflow 55% filters DX coil Silencer + COARSE damper - exhaust wheel - - supply wheel - - exhaust Humidifier
AHU (Config. (Config. filters (Config. (Config. heater
ODU NOM - supply 55% filters- -exhaust (Config. supply (Config. exhaust (Config.
SIZE A-E) B-C) E) E)
MAX supply D) E) E)

m3/h Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa

MIN 4,300 1 12 91 156 55 26 206 120 91 162 93 144 159 84 7 - -

10HP 025 NOM 4,500 1 13 98 158 59 28 210 122 95 167 93 146 165 95 8 - -

MAX 5,000 2 16 99 164 71 36 235 147 96 187 95 150 185 96 10 - -

MIN 5,000 1 4 91 138 37 4 154 70 91 116 89 135 114 91 4 - -

14HP 040 NOM 7,200 2 13 87 149 68 10 240 145 87 172 93 144 169 94 8 - -

MAX 8,000 2 16 96 153 82 12 243 165 96 193 94 147 190 96 9 - -

MIN 8,100 1 12 96 153 50 10 225 139 92 167 94 147 165 92 9 - -

18HP 048 NOM 8,600 1 13 97 156 55 11 241 155 93 178 95 149 176 93 10 - -

MAX 9,100 2 15 98 159 60 13 257 171 93 189 95 152 187 93 11 - -

MIN 11,000 1 8 91 140 30 9 148 62 90 121 90 137 119 90 6 - -


2X
080 NOM 14,500 2 14 94 148 47 16 188 101 93 163 93 143 161 93 10 - -
14HP
MAX 16,100 2 17 96 153 56 19 209 122 94 183 94 147 180 94 13 - -

MIN 16,000 1 10 96 152 37 16 157 74 91 146 92 142 144 91 10 - -


2X
096 NOM 17,300 1 11 97 156 42 19 168 86 92 159 93 145 157 92 11 - -
18HP
MAX 18,100 1 13 98 158 46 21 175 93 92 167 93 146 165 92 13 - -

254
Fan Characteristic Curves

Fan type 400 mm

1,400

1,200

1,000

800

600

400
1,100
1,650
200
2,400

0 1,950
0 2,000 4,000 6,000 8,000 10,000

VENTILATION
Pa n LwAin LwAout
fan type m3/h W
Total static pressure [1/min] [dB] [dB]
400 mm 156 265 124 1100 63 71
400 mm 334 265 134 1100 63 70
400 mm 1002 265 187 1100 62 69
400 mm 1025 265 181 1100 62 69
400 mm 2072 228 234 1100 58 66
400 mm 3275 119 224 1100 62 69
400 mm 3809 16 173 1100 69 74
400 mm 223 622 352 1650 75 82
400 mm 2005 591 642 1650 72 79
400 mm 3564 493 767 1650 68 75
400 mm 4656 321 708 1650 71 77
400 mm 5770 21 487 1650 79 83
400 mm 200 840 509 1950 79 86
400 mm 3163 783 1154 1950 74 81
400 mm 4946 570 1223 1950 74 80
400 mm 5948 316 1027 1950 78 83
400 mm 6750 41 773 1950 83 87
400 mm 245 1276 921 2400 85 92
400 mm 1649 1244 1497 2400 86 92
400 mm 4163 1165 2223 2400 81 87
400 mm 6438 783 2237 2400 81 87
400 mm 7864 296 1738 2400 86 91
400 mm 8510 10 1389 2392 89 93

255
VENTILATION

Fan type 560 mm

1,200

1,000

800

600

400
800

200 1,200
1,400

0 1,550
0 5,000 10,000 15,000 20,000

Pa n LwAin LwAout
fan type m3/h W
Total static pressure [1/min] [dB] [dB]
560 mm 158 276 209 800 65 72
560 mm 1861 270 345 800 65 71
560 mm 3921 236 438 800 61 67
560 mm 5980 130 452 800 62 67
560 mm 7881 4 313 800 69 74
560 mm 158 627 591 1200 77 83
560 mm 3327 596 1164 1200 75 82
560 mm 6139 547 1471 1200 71 77
560 mm 8950 386 1473 1200 72 78
560 mm 10653 190 1212 1200 76 82
560 mm 11921 11 936 1200 80 85
560 mm 238 837 901 1400 80 87
560 mm 3446 824 1743 1400 80 87
560 mm 8000 715 2403 1400 75 81
560 mm 10693 493 2260 1400 76 82
560 mm 12475 243 1859 1400 80 86
560 mm 13861 38 1521 1400 85 89
560 mm 198 1046 1210 1550 84 90
560 mm 2812 995 2086 1550 84 91
560 mm 7485 939 3131 1550 78 84
560 mm 10059 774 3249 1550 77 84
560 mm 13188 453 2901 1550 82 88
560 mm 15564 2 1948 1550 91 94

256
Fan type 710 mm

1,600

1,400

1,200

1,000

800

600

400
700
1,000
200
1,250

0 1,400
0 5,000 10,000 15,000 20.000 25,000 30,000

VENTILATION
Pa n LwAin LwAout
fan type m3/h W
Total static pressure [1/min] [dB] [dB]
710 mm 891 361 744 700 71 77
710 mm 4975 332 1290 700 69 74
710 mm 10025 196 1427 700 69 75
710 mm 13515 6 880 700 77 83
710 mm 1708 788 1693 1000 81 88
710 mm 9876 670 3179 1000 77 83
710 mm 16634 338 3084 1000 80 86
710 mm 20124 24 2177 1000 87 93
710 mm 2228 1179 3015 1250 87 94
710 mm 15297 901 6054 1250 83 89
710 mm 20495 563 5794 1250 86 92
710 mm 25173 12 3857 1250 92 98
710 mm 1821 1421 3716 1400 89 96
710 mm 7500 1380 5851 1400 89 95
710 mm 17996 1110 8301 1400 86 92
710 mm 24855 445 6916 1400 91 98
710 mm 27685 40 5271 1400 95 101

257
VENTILATION

Specifications

Configuration A-B-C

Model FG 025 040 048 080 096 Model FG

AHYA025GWA* AHYA040GWA* AHYA048GWA* AHYA080GWA* AHYA096GWA*


Model name AHYB025GWA* AHYB040GWA* AHYB048GWA* AHYB080GWA* AHYB096GWA* Model name
AHYC025GWA* AHYC040GWA* AHYC048GWA* AHYC080GWA* AHYC096GWA*

Casing Casing
Material Outer skin in 0.6 mm pre-painted galvanised sheet; inner skin in 0.6 mm galvanised sheet Material
Insulation PU foam, 50 mm thickness, 45 kg/m3 Insulation
Performances Performances
Cooling capacity kW 25 40 48 78 96 Cooling capacity kW
Heating capacity kW 31.5 45 50 81.5 100 Heating capacity kW
Available static pressure Pa 200 200 200 200 200 Available static pressure Pa
Power supply V/Ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Power supply V/Ph/Hz
$LUÁRZ $LUÁRZ
Max m³/h 5000 8000 9100 16100 18100 Max m³/h
Rated m³/h 4500 7200 8600 14500 17300 Rated m³/h
Min m³/h 4300 5000 8100 11000 16000 Min m³/h
Cross flow heat recovery Heat recovery
Efficiency (*) % – – – – – Efficiency (*) %
Eurovent Energy Class (**) Eurovent Energy Class (**)
Rated A+ A A A A Rated
DX Coil DX Coil
Rows n° 4 Rows n°
Coil type 25x22 - 3/8" Coil type
Coil duty Cooling - Heating Coil duty
Fluid R410A Fluid
Pipes material Copper Pipes material
Fins material Aluminium Fins material
Electrical heating Electrical heating
Stages n° 3 Stages n°
Heating capacity kW 9 15 18 30 36 Heating capacity kW
+XPLGLÀHU +XPLGLÀHU
Fix steam capacity kg/h 15 25 30 45 60
Fan Fan
Type EC Plug Fan Type
mm 400 560 560 710 710 mm
Motor data Motor data
kW 2.4 3.4 3.4 7.3 7.3 kW

Thermal transmittance of the Thermal transmittance of the


T3 T3 T3 T3 T3
casing(TT) class casing(TT) class
Thermal bridging factor(TBF) class TB3 TB3 TB3 TB3 TB3 Thermal bridging factor(TBF) class
Casing strength(CS) class D2(M) D2(M) D2(M) D2(M) D2(M) Casing strength(CS) class
Casing air leakage(CAL) class@-400Pa L2(M) L2(M) L2(M) L2(M) L2(M) Casing air leakage(CAL) class@-400Pa
Casing air leakage(CAL) class@+700Pa >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) Casing air leakage(CAL) class@+700Pa
Filter bypass leakage (FBL) class F9(M) F9(M) F9(M) F9(M) F9(M) Filter bypass leakage (FBL) class

DWUDWHGDLUÁRZ
(**) configuration 1

258
Configuration D Configuration E

025 040 048 080 096 025 040 048 080 096

AHYD025GWA* AHYD040GWA* AHYD048GWA* AHYD080GWA* AHYD096GWA* AHYE025GWA* AHYE040GWA* AHYE048GWA* AHYE080GWA* AHYE096GWA*

Outer skin in 0,6 mm pre-painted galvanised sheet; inner skin in 0,6 mm galvanised sheet Outer skin in 0,6 mm pre-painted galvanised sheet; inner skin in 0,6 mm galvanised sheet
PU foam, 50 mm thickness, 45 kg/m3 PU foam, 50 mm thickness, 45 kg/m3

25 40 48 78 96 25 40 48 78 96
31.5 45 50 81.5 100 31.5 45 50 81.5 100
200 200 200 200 200 200 200 200 200 200
400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50

5000 8000 9100 16100 18100 5000 8000 9100 16100 18100
4500 7200 8600 14500 17300 4500 7200 8600 14500 17300
4300 5000 8100 11000 16000 4300 5000 8100 11000 16000

73.3 74.4 74.2 73.7 73.6 75.6 74.7 74.2 75.3 75.6

VENTILATION
A+ A+ A+ A+ A A+ A+ A+ A A

4 4
25x22 - 3/8" 25x22 - 3/8"
Cooling - Heating Cooling - Heating
R410A R410A
Copper Copper
Aluminium Aluminium

3 3
9 15 18 30 36 9 15 18 30 36

15 25 30 45 60 15 25 30 45 60

EC Plug Fan EC Plug Fan

2.4 3.4 3.4 7.3 7.3 2.4 3.4 3.4 7.3 7.3

T3 T3 T3 T3 T3 T3 T3 T3 T3 T3

TB3 TB3 TB3 TB3 TB3 TB3 TB3 TB3 TB3 TB3
D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M) D2(M)
L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M) L2(M)
>L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M) >L3(M)
F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M) F9(M)

DWUDWHGDLUÁRZ
(**) configuration 1

259
VENTILATION

Control System

AHU units include built-in electrical panel and


expansion valve with PCB control. Set point is fixed
via standard wired control.
The cooling load is determined by the air return
temperature and set point on the wired control.

AHU Controller
UTY-TXUX

Features
• Easy to install. Control connects to AHU PLC.
• Able to install the control after building decoration.
• Mode lock function: user can lock the running mode of Air Handling Unit.

Easy Opration
The remote controller realised an intuitive operation feeling by touch panel
operation.

Functions
• Schedule setting change
• Set temperature and humidity
• Ambient’s name
• Alarms setting
• Event setting

Specifications
Model name UTY-TXUX
Format mm 120 x 86 x 25
Display Display touch color 3.5” 320 x 240
Power supply 24 Vac - 24 Vac/dc
Analogue inputs 1 x Integrated NTC
Connectivity RS485 - Modbus SL, USB Micro-B (debug and programming)
Operating temperature 0 – +50 °C

260
System Controller System Controller Lite
UTY-APGXZ1 UTY-ALGXZ1 + UTY-PLGXX2

Features Features
System Controller realises the advanced integrated monitoring System Controller Lite has standard functions sufficient for
& control of VRF network system from small scale buildings to air conditioner management in small and medium scale
large scale buildings. buildings.
• Up to a maximum of 4 VRF network systems, 1,600 indoor • Up to a maximum of 1 VRF network system, 400 indoor
units, and 400 outdoor units can be controlled. units, and 100 outdoor units can be controlled.
• In addition to air conditioning precision control function, • In addition to air conditioning precision control function, a
central remote control, electricity charge calculation, schedule variety of management software is available as an option
management, and energy saving functions are strengthened to give customers a wide range of choice.
and building manager and owner needs are met.

Max. Controllable Max. Controllable

4 VRF network systems 1 VRF network systems


Max. Controllable Max. Controllable

400 outdoor units 100 outdoor units


Max. Controllable Max. Controllable

1,600 indoor units 400 indoor units

VENTILATION

It is possible to perform centralised control to VRF


indoor units
stop the operation of lighting and ventilation
equipment in addition to air conditioners.
This is useful in energy saving management over
Facilities
the whole building. Energy Recovery
Lightning Ventilation Ventilator

261
VENTILATION

Functions Summary
System controller System controller lite

Function Type Option Option Option Option Option


UTY- UTY-
APGXZ1 UTY- ALGXZ1 UTY- UTY- UTY- UTY-
PEGXZ1 PLGXR2 PLGXA2 PLGXE2 PLGXX2
Max. VRF networks supported 4 - 1 - - - -
Max. indoor unit / remote controller groups per VRF network 400 - 400 - - - -
System
Max. outdoor units per VRF network 100 - 100 - - - -
specification
Max. indoor units / remote controller groups per System controller 1600 - 400 - - - -
Max. outdoor units per System controller 400 - 100 - - - -
Multi site display 10 - 10 - - - -
Number of building / 1 site 20 - - - - - -
Number of floor per 1 site 200 - - - - - -
Number of floor per 1 building 50 - - - - - -
Site
3D graphical layout view z - - - - - -
supervision
2D graphical layout view z - - - - - -
List display z - z - - - -
Tree display z - z - - - -
Group display z - z - - - -
Error notification z - z - - - -
Error
Audible alarm z - z - - - -
management
Error e-mail notification z - z - - - -
Error history z - z - - - -
History Operation history z - z - - - -
Control history z - z - - - -
On/Off z - z - - - -
Operation mode* z - z - - - -
Room temperature z - z - - - -
Fan speed z - z - - - -
Individual
Air flow direction z - z - - - -
control
Economy mode z - z - - - -

Operation Room temperature set point limitation z - z - - - -


control Antifreeze z - z - - - -
Outdoor unit low noise setting z - z - - - -
Remote control prohibition setting z - z - - - -
Individual
Temperature upper and lower limit setting z - z - - - -
management
Filter sign reset z - z - - - -
Memory operation z - z - - - -
Other
Pattern operation z - z - - - -
Annual Schedule z - z - - - -
Special day setting z - z - - - -
On / off per day 72 - 72 - - - -
Schedule On / off per week 504 - 504 - - - -
Day off z - z - - - -
Min. unit of timer setting (Minutes) 10 - 10 - - - -
Low noise mode Weekly schedule z - z - - - -
Web Operation z - z - - - -

Remote Remote monitoring z - - z - - -


management Remote operation control z - - z - - -
Remote function setting z - - z - - -
Apportionment charge/bill calculation z - - - z - -
Tenant (block) setting z - - - z - -
Electricity Common facilities apportionment setting z - - - z - -
charge
Rated power consumption allotment setting z - - - z - -
apportionment
Individual calculation at cooling and heating - z - - z - -
Electricity meter supported - z - - z - -
Indoor unit rotation - z - - - z -
Peak cut control - z - - - z -

Energy Outdoor unit capacity save - z - - - z -


saving Record of energy saving operation - z - - - z -
management Energy saving information - z - - - z -
Power consumption monitor - z - - - z -
Electricity meter supported z - - z -

External Device Monitor z - - - - - z


Control Control z - - - - - z
Database import/export z - z - - - -
Automatic clock adjustment z - z - - - -
Others Multi language 7 languages - 7 languages - - - -
Refrigerant leakage detection function z - z - - - -
Power shutdown z - z - - - -

zz: Available. - : Not available.

262
Personal Computer System Requirements
The required PC specifications are shown in the following table.

System Controller System Controller Lite


• Microsoft® Windows® 7 Home Premium (32-bit or 64-bit) SP1, Windows® 7 Professional (32-bit or 64-bit) SP1
Operating • Microsoft® Windows® 8.1 (32-bit or 64-bit), Windows® 8.1 Pro (32-bit or 64-bit)
system • Microsoft® Windows® 10 Home (32-bit or 64-bit), Windows® 10 Pro (32-bit or 64-bit)
[Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish
CPU Intel® CoreTM i3 2 GHz or higher
• 2 GB or more (for Windows® 7 [32-bit])
Memory
• 4 GB or more (for Windows® 7 [64-bit], Windows® 8.1, and Windows® 10)
HDD 40 GB or more of free space
Display 1024 x 768 or higher resolution
• Ethernet port (for getting access to the Internet using LAN) or Modem • Ethernet port (for getting access to the Internet using LAN) or Modem
(for getting access to the Internet using Public Telephone Line) (for getting access to the Internet using Public Telephone Line)
• USB ports (Maximum of 6 ports) • USB ports (Maximum of 6 ports)
(Required only for the Server PC that works as VRF Controller) (Required only for the Server PC that works as VRF Controller)
- Maximum of 2 USB ports are required for WHITE-USB-KEY/WibuKey - Maximum of 4 USB ports are required for WHITE-USB-KEY/WibuKey
Interface connection connection
- Maximum of 4 USB ports are required for Echelon® U10 USB Network - 1 USB port is required for Echelon® U10 USB Network Interface
Interface * The maximum number of required USB port depends on the
* Maximum number of required USB port depends on the applicable DSSOLFDEOHV\VWHPFRQÀJXUDWLRQ
V\VWHPFRQÀJXUDWLRQ

Graphic
Microsoft® DirectX® 9.0c compatible
accelerator
Software Adobe® Reader® 9.0 or later
• Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.)

Packing List
For System controller For System controller Lite

VENTILATION
Option Option
Type
System System
Controller Energy Controller Lite Electricity charge
Remote access Energy saving Central Control
manager apportionment
Model name UTY-APGXZ1 UTY-PEGXZ1 UTY-ALGXZ1 UTY-PLGXR2 UTY-PLGXA2 UTY-PLGXE2 UTY-PLGXX2
WHITE-USB-KEY 1 1 1 1 1 1 1
*1: Software protection key to be inserted in a USB slot running System Controller or System Controller Lite.
System Controller or System Controller Lite may only run on a PC with WHITE-USB-KEY. However, WHITE-USB-KEY is not required for remote VRF Explorer software.

263
Notice for specifications

I.U. = Indoor Unit O.U. = Outdoor Unit Qu = Quiet * = Not decided yet
• Specifications and design are subject to change without notice for future improvement.
• For further details, please check with our authorised dealer.
• Cooling/Heating capacities are based on the following conditions.

Indoor temp. : 27°C DB/19°C WB Indoor temp. : 20°C DB


Cooling Heating
Outdoor temp.: 35°C DB/24°C WB Outdoor temp.: 7°C DB/6°C WB

UK Indoor temp. : 23°C DB/16°C WB UK Indoor temp. : 20°C DB


Cooling Heating
Conditions Outdoor temp.: 35°C Conditions Outdoor temp.: 0°C DB/-2°C WB

• Performance test is in accordance with EN14511


• Seasonal efficiency test is on accordance with EN14825
• Sound power test is in accordance with EN12102

Fujitsu General (Thailand) Co., Ltd.

ISO 9001 Certified number: 01 100 075229


ISO 14001 Certified number: 01 104 9245

Fujitsu General (Shanghai) Co., Ltd.

ISO 9001 Certified number: ISO 14001 Certified number:


01 100 79269 CNBJ312244-UK

Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.

ISO 9001 Certified number: ISO 14001 Certified number:


15917Q20073R5M 15918E20021R5M

• The products or equipments in this catalogue contain fluorinated greenhouse gases.


•“ ” is a worldwide trademarks of FUJITSU GENERAL LIMITED and are
registered trademarks in Japan and other countries or areas.
•“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED.
•“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED.
• “DUAL BLASTER & device” is a worldwide trademark of FUJITSU GENERAL LIMITED and
is a registered trademark in Japan and other countries or areas.
• iPhone and iPod touch are trademarks of Apple Inc., registered in the U.S. and other
countries.
• “Microsoft”, “Windows”, “Direct X” are trademarks of Microsoft Corporation in the
United States and certain other countries.
• IntesisHome® is a registered trademark of Intesis Software S.L.
• “BACnet” is a trademark or registered trademark of the American Society of Heating,
Refrigerating and Air-Conditioning Engineers, Inc.
• “MODBUS” is a registered trademark of Schneider Electric.
• “LONWORKS” and Echelon are trademarks of Echelon Corporation registered
in the United states and other countries.
• Adobe® Reader® is either registered trademarks or trademarks of Adobe Systems
Incorporated in the United States and/or other countries.
• Other company and product names mentioned herein may be registered trademarks,
trademarks or trade names of their respective owners.