Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
364 views
Firerex Booklet - Compressed FM200
fm200
Uploaded by
Ar Jun
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save Firerex Booklet_ Compressed FM200 For Later
Download
Save
Save Firerex Booklet_ Compressed FM200 For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
0 ratings
0% found this document useful (0 votes)
364 views
Firerex Booklet - Compressed FM200
fm200
Uploaded by
Ar Jun
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save Firerex Booklet_ Compressed FM200 For Later
Carousel Previous
Carousel Next
Save
Save Firerex Booklet_ Compressed FM200 For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
Download now
Download
You are on page 1
/ 8
Search
Fullscreen
- FIREREX FIREREX 227 Fire Suppression System For 25 / 42 BAR HFC-227ea®© FIREREX FIREREX 227 ‘The bes protection for high-value assets requires a product that could meet al the criteria necessary to minimize the risk offre damages. Halon 1301 has been widely used asi proves tobe an effective fire suppression agent, but Halon 1301 has significant environmental consequences due toits potential contribution to depleting the ozone ayer. ‘The quest fora replacement resulted inthe introduction of Clean Agent - HFC-227ea to the marketplace. Ithas been designated asa replacement for FC propellants in pharmaceutical metered dose inhalers in asthma medications. Known as the world most widely accepted replacement for Halon 1301, HC-227ea is considered as peope-riendly and takes up less or space ‘than ather systems. The U.S Environmental Protection Agency named it anon-czone depleting agent for fire extinguishing systems installed in occupied paces. ‘The FIREREX-227 System is ideal for applications where clean-up of other metium presents a problem, where an electrically non-conductive medium is needed and where people compatibility isan overriding factor. Ithas ero Ozone-Depleting Potential, Low Global Warming Potential and Shor Atmospheric lifetime. These characterstis make tsuitable not only fornew installation using total flooding system, but als for Halon 1301 replacement applications Agent Characteristics Firerex-227's agent (HFC-2276a) isan odores, colorless liquefied compressed gas. Its stored a liquid and dispensed into hazard a a colorless, electrically non-conductive vapor that i clear and does not obscure physical vision. I leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. Firetex-227 extinguishes a fire by a combination of chemical and physical mechanisms. Fterex-227's agent doesnot displace and therefore ssfe for use in ocupied spaces without fear of oxygen deprivation Firerex-227's agent (HFC-227ea) i Underwriters Laboratories (UL) Listed approved Clean Agent Fire Suppressant produc. The present understanding ofthe functioning of HC-227ea is that 8056 ofits ite fighting effectiveness achieved through heat absorption and 20% through direct chemical means. Summary of Agent Physical and Chemical Characteristics Chemica Structure CHIC: Chemical Name 1,1, 1,233.3 -Heptafluoropropane Molecular Weight 170 g/mal Boiling Point at 1.013 Bar (2bs) “16 4°C/ 248° Freezing Point Citial Temperature Cita Pressure Cita Density Specitic Heat, Liquid at 25°C “131°C -208*F 1017°C/215.1°F 29.1 Bar (422i) 621 kg/m (38.76 Lit) 1iB4W/kg"C Specific Heat, 25°C Vapor at constant pressure 1 atm and 25°C 0.808 Kika" Heat of Vaporzation at Boiling Point 132610/kg Thermal Conductivity of Liquid @ 25°C 0.069 Wim'C Viscosity, Liquid a Cntipise 25°C 0.184 Relative Dielectric Strength @ 1 atm 2 Solubility of Water in Agent @ 21°C 0.06% by weight Saturated Vapor Density @ 20°C (68°) 31.18kg/n (1.95 bf) ‘zone Depletion (ODP) ° Global Warming Potential (GP) 3,220 ‘Mmospherc Lifetime H2yts No Observed Adverse Effect Level (NOAEL) 1% Lowest Observed Adverse Eect Level LOREL) >105%Advantages © FIREREX ZERO NO + Ozone Depletion Potential «Decomposition products LOW + Fogging when discharged + Residue to clean up after discharge + Global Warming Potential NON Toxic = Corrosive + Hlcticlly Conductive + Colour & Odour + Atmospheric Lifetime System Application Power Generation te itary Healthcare + Power Pant Ng Lambateies *CSan & + Power Transmission Miltary Aviation MRIControl Room + Substation + Control Rooms + Medical Record Room Data Processing {D> Transportation Cultural «Computer Rooms « Light Rapid Transits 5} + Museums + Data Storage Faclities Gess'S| «Mass Transit Vehicles WZ + Libraries + Server Rooms + Commercial Aviation «Archives Telecommunication Commercial Marine Miscellaneous + Cellular Sites Engine Rooms - Bank Vaults + Microwave Relay Towers «Control Rooms + Radio & TV Stations + PBX & IDF Rooms + Storage Rooms + Laboratories Approval & Certificates dS Schadenverhatung Bomba Certificate Certificate Sijil Guna Paka© FIREREX System Design and Operation The Frerex-227 fire suppression systems are designed, installed and maintained according to Nati Standatd On Clean Agent Fie Extinguishing Systems). ional Fire Protection Association (NFPA 2001 Firerex-227 is employed asa total flooding system and should not be used for local application system. Firerex-227 suppresses fire by absorb ing heat energy at its molecular level faster than the heat can be generated, so the fire cannot sust stain itself System temperature limits are 32°F (0°) to 130*F (54.4°C) and system operating pressure is 360 ps (25 Bar) at JO (21.1°C) and 610 psi (42 Bar) at 70°F (21.1°0 1 Piping 6 Alarm Bell 2 HFC-227ea Cylinder 7 Abort Switch 3 Smoke / Heat Detector 8 Twin lashing Light 4 Nozzle 9 Electromagnetic Actuator 5 Control Panel 10 Manual / Pneumatic Actuator’ Protection Efficiency System have an excellent extinguishing efficiency with fies of Class A, B and C. ‘ass of Fire . (NFPA 2001) ‘lass of Fire (Asia) ‘Type of Fire Fire Sources A A Surface Fires ‘Wood, Rubbers, Paper, Fabric etc 8 Flammable Liquid ies Gasoline, Kerosene, ec y C Flammable Gas Fires Methanol, Propane, LPG, etc c E Energized Electrical Fire Energised Electrical Equipment Example of Typical Calculation for System: lass of Fire Classik Class B Class Dimensions of Protected Room 0m (1) x8.7m (W)x4.0m (H) Volume of Protected Room 243.6m Design Temperature 20 Extinguishing Design Concentration NeHeptane Transformer oil {according to NFPA 2001 :2018) 61% 87% 95% 702% Flooding Factor an ss 0765 055 ‘Agent Required = Volume of Room to be Protected x Flooding Factor, 12667 (243.6052) | 168.15 (248.6x0.6944) | 186.35 263.6x0.765) | 133.98 (243.6x0.5) ‘Agent Required in Kg (Round Up) 127g V70kg 187k Tag© FIREREX | Fire Suppression System Components voltorsol | Ta0L to240L waLtoddl ‘ol tao 355M Stel late 37Mtn 30cMo ds Bar at70°C Abarat 11°C 63 Bar (Pneumatic) 90 Bar (Hydraulic) | 150 Bar (Hydrate) Glinders 1 Matin . = eel Eaecc es Som A 25 Bar System (Welded Cylinder) FHC W052 2 N33, 798 324 BE race ie us n as bs rewnn te | omsoms | tne a“ m —_— omens “ ous na a“ m rewima ‘i ue 2a ia 7 Heri nm owe os ma 7 FHC W240 0 ‘DNAS 1644 482. 202 42 Bar System (Seamless Cylinder) resume a owe s 1 7 aiesue “ owe on a 7 @ FHCST80, 180 ‘DNAS 1650 406 202 Valve Assembly BoAE2 Type N33. BO4B1 Type DN4D ratio Mate [Mouse | os | 2 | as | a ([Dutletconnecion = 17/8"-male 20 male BS (2) Gnitoiernsaes os | | sovrnye00s — tourtyeony AES) nn ‘nm a Electromagnetic Release Device Pressure Gauge 0 100Bar sone 2 =r [Body Brass Staines Stee [Bale 0- o8ar | 0- 100807 [tng eset me eemedion fer | Ren woes == 4mm | Momintvatge 100 SS ecomeon || “© FIREREX Boseze221 | Optional Items #O asr20171 aa sno osoze222 anos ox720174 ‘Manual / Pneumatic Release Device 0442000 Brass Stainless Stee Stainless Stee <20Ba 300 ar Maxis ae" 80692024K SyntheticRubber OibResistant maxts 700mm 7mm 4008ar 1600 Bar Discharge Hoses 306920221 Symthetic Rubber 1718. aur 500mm s10mm | s3Bar 1598ar Check Valve RP S3Bar 6mm Pressure Switch 7 z = E z a Bo4s1200K Bo4sT200K Boust220K Bo46T234K o4sr26nK 0451254 Brass 360 or 180 versions 00 Bar 06920222 i Resistant 2M Re 550mm 640mm Rai 80mm nsbar 38bar ‘Soar 0-40 bar o-6obar o-sobar Rear-2wires | Rear-2wites | Rear-2wites 55mm 255mm 255mm Mi0x1 Miox1 miox1© FIREREX | Fire Detection System Components Gas Extinguishing Panel PartNo. br03 Material Back Box (Metal) / id (Past) ‘Main Supply Voltage 2BOVAC, So/6oHe Internal Power Supply 24¥0CNominal Output Current 3A@ 230VAC Max) Battery Requirement 2x T2VOCTAH Sounder Output Rating 21-28 VOC, Fused@200mA per Cut Relay Contact Rating 30VDC, 1A Max ‘Maximum Detectors per Zone IDNs Extinguishant Release Output 21-28 VDC Rated at 1A for Sins Dimension 439 mmx276mmx70 mm ROR & Fixed Temperature Heat Detector PartNo. Voltage D¢ ‘Standby Curent (Max) yA ‘Alarm Current (Max) ‘Temperature Range Material of Body Dimension (mm) Evacuate Sign PartNo, Operating Voltage Operating Caents Dimension (mm) Alarm Bell PartNo. Operating Voltage ‘arm Current Decibel Rating @3m (10ft) Dimension (mim) Manual Abort Station PartNo. Protection Rating (Current Ratings Dimension (mn) 5000-139 NC 91033 sou Samat 24V0C orcto37 770 Palyctbonate 2 00x42 o-110l ravoc 240mA-Bu / 20mAED 8 (Ux 260 (Wx 110) om 2avoc Cory 95db 21x71 -108 Poa Amp @ 240 VAC 2Amps @ 24VDC 88 (L) x88 (0x55 Photoelectric Smoke Detector PartNo. Voltage DC ‘Alarm Current (Max) ‘Temperature Range Material of Body Dimension (mn) Double Flashing Light PartNo. Operating Voltage Operating Current Dimension (mm) Standby Current (Max) yA 5500-326 1MC 90 3006 45yhat24V0C stat 24V0C -20°Cta 60" Polycarbonate © 10x42 D-t04 ravoc ‘WOmA-Bulb /20mA-LED 78(U x210 (0) x 105 (4) Sealed Lead Acid Battery PartNo. Normal Voltage Gapacity Dimension (mm) Manual Key Switch PartNo. Dimension 0-105 (mm) Kp-307 wrnv79 aw TAKmin at 20 Hours Discharging Time 151 (1) x65 (0) x95 (4) -105 KP-307 105 (L) x 100 (0) x 105 (H) 110 (1) x90) x 110%)© FIREREX System Setup rn ronie er een Pee err fet RoI Release Device Pressure Gauge Cg Room Integrity Test ‘According to NFPA 2001 standards, its crucial forthe extinguishing agent to be retained inthe protected room for an extended period of time (minimum 10 minutes) to prevent re-ignition and spread offre. To achieve this goal, Firerex Technology Sdn. Bhd. provides this service using acallbrated door fan test unit without discharging any extinguishing agent. ‘The extinguishment effectiveness of any gaseous system depends largely on achieving the designed concentration in a toom and how lang it can be maintained to prevent re-ignition and spread of the fire. Based on the standards, the agent needs to be maintained for 10 minutes Toachieve this, the door blower fan system suseto check the leaktightnes ofthe room. The ‘values obtained from these tests will be evaluated and compared to known tested values to ‘show thatthe room is sufficiently tight to contain the extinguishing agent for the required petod of time Firerex Technology Sdn. Bhd No. 68, Jalan Gambus 33/4, Seksyen 33, 40400 Shah Alam, Selangor Darul Ehsan, Malaysia. Tel +603 5525 2599 Fax +603 55255529 Email
[email protected]
You might also like
Sffeco 227 Ul-Fm
PDF
No ratings yet
Sffeco 227 Ul-Fm
14 pages
Croker PDF Catalog 2009
PDF
No ratings yet
Croker PDF Catalog 2009
153 pages
Fire Alarm Isolation Permit - Form A
PDF
0% (1)
Fire Alarm Isolation Permit - Form A
1 page
Fire Hydrant Equipment NAFFCO
PDF
No ratings yet
Fire Hydrant Equipment NAFFCO
6 pages
Kidde - Fluoro-K - Fire - Suppression - Clean Agent - K-45-0900
PDF
No ratings yet
Kidde - Fluoro-K - Fire - Suppression - Clean Agent - K-45-0900
2 pages
36571 Product Catalog Fireking CAS FK Extinguishing Systems Product
PDF
No ratings yet
36571 Product Catalog Fireking CAS FK Extinguishing Systems Product
116 pages
Foam Naffco
PDF
No ratings yet
Foam Naffco
1 page
VF1445-XX Elite-H Installation Manual
PDF
No ratings yet
VF1445-XX Elite-H Installation Manual
128 pages
Product Manual DCP Trolley Mounted 25-50-75 KG
PDF
No ratings yet
Product Manual DCP Trolley Mounted 25-50-75 KG
6 pages
FM Global Property Loss Prevention Data Sheets: Foam Extinguishing Systems
PDF
No ratings yet
FM Global Property Loss Prevention Data Sheets: Foam Extinguishing Systems
78 pages
Flow-Switch-Rapidrop
PDF
No ratings yet
Flow-Switch-Rapidrop
4 pages
Duct Smoke Detector Testing
PDF
No ratings yet
Duct Smoke Detector Testing
1 page
FSSA White Paper - Fire Safety Systems Protecting Data Centers
PDF
No ratings yet
FSSA White Paper - Fire Safety Systems Protecting Data Centers
8 pages
Hydraulic Calculations Pressure Drop Calculation For Sprinklers
PDF
No ratings yet
Hydraulic Calculations Pressure Drop Calculation For Sprinklers
12 pages
Spec Pava
PDF
No ratings yet
Spec Pava
10 pages
Where To Start. Knowing The System's Age and Maintenance History
PDF
No ratings yet
Where To Start. Knowing The System's Age and Maintenance History
4 pages
UL Listed 42 Bar HFC-227ea (FM-200) Clean Agent System
PDF
100% (1)
UL Listed 42 Bar HFC-227ea (FM-200) Clean Agent System
6 pages
Fpe Cwsi Wireless Fire Alarm Systems
PDF
No ratings yet
Fpe Cwsi Wireless Fire Alarm Systems
43 pages
003 Diom Manual Ilp Novec 1230
PDF
No ratings yet
003 Diom Manual Ilp Novec 1230
49 pages
Inspection Form - Fire Pump
PDF
No ratings yet
Inspection Form - Fire Pump
2 pages
Guidelines On Inspections and Maintenance of FEs at Mobilty Stations
PDF
100% (1)
Guidelines On Inspections and Maintenance of FEs at Mobilty Stations
28 pages
Co2 Gas Flooding System
PDF
No ratings yet
Co2 Gas Flooding System
6 pages
Heat Detector UL Certificate
PDF
No ratings yet
Heat Detector UL Certificate
1 page
Clarke Diesel Installation Guidelines
PDF
No ratings yet
Clarke Diesel Installation Guidelines
59 pages
NATAAircraft Hangar Fire Protection Guidance
PDF
No ratings yet
NATAAircraft Hangar Fire Protection Guidance
5 pages
QCDD TEST For Fire Alarm Engineers
PDF
No ratings yet
QCDD TEST For Fire Alarm Engineers
1 page
Naf S 125 15 03 07
PDF
No ratings yet
Naf S 125 15 03 07
38 pages
Fire Alarm Systems Plan Review Checklist NFPA 72 2007 Edition
PDF
No ratings yet
Fire Alarm Systems Plan Review Checklist NFPA 72 2007 Edition
6 pages
Shield Water Spray Nozzle
PDF
No ratings yet
Shield Water Spray Nozzle
17 pages
Ul - 4906-9127
PDF
100% (1)
Ul - 4906-9127
2 pages
Automatic Fire Suppression Systems
PDF
No ratings yet
Automatic Fire Suppression Systems
1 page
Gent Catalogue 2010
PDF
100% (2)
Gent Catalogue 2010
202 pages
85001-0239 - Control Relay Modules
PDF
No ratings yet
85001-0239 - Control Relay Modules
6 pages
A3 Mimic Panel
PDF
No ratings yet
A3 Mimic Panel
4 pages
BFE-FM200-EPFS-000-02 - System Datasheet (UL)
PDF
No ratings yet
BFE-FM200-EPFS-000-02 - System Datasheet (UL)
52 pages
Fire Safety Maintenance Checklist: Daily Checks (Not Normally Recorded) Yes No N/A Comments
PDF
No ratings yet
Fire Safety Maintenance Checklist: Daily Checks (Not Normally Recorded) Yes No N/A Comments
3 pages
4098 0018 Ioniz Conv Detec
PDF
100% (1)
4098 0018 Ioniz Conv Detec
4 pages
Wilo Fire Fighting - 2021
PDF
No ratings yet
Wilo Fire Fighting - 2021
16 pages
Fire Pump Field Acceptance Test QCDD Form
PDF
No ratings yet
Fire Pump Field Acceptance Test QCDD Form
6 pages
MX Zonecheck PDF
PDF
No ratings yet
MX Zonecheck PDF
2 pages
FirePro Xtinguish V1.03
PDF
100% (2)
FirePro Xtinguish V1.03
99 pages
Nfpa 17a
PDF
No ratings yet
Nfpa 17a
17 pages
Boq - Fire Alarm System
PDF
No ratings yet
Boq - Fire Alarm System
3 pages
Water Fire Extinguishers
PDF
No ratings yet
Water Fire Extinguishers
4 pages
Wet Riser Specification
PDF
No ratings yet
Wet Riser Specification
4 pages
FDAS System Maintenance Avesco
PDF
No ratings yet
FDAS System Maintenance Avesco
8 pages
Foam-Water Spray Extinguishing System, Powerhouse Diesel Eng
PDF
No ratings yet
Foam-Water Spray Extinguishing System, Powerhouse Diesel Eng
10 pages
DD Electric Driven Fire Pump Specification
PDF
No ratings yet
DD Electric Driven Fire Pump Specification
16 pages
Gas Fire Protection
PDF
No ratings yet
Gas Fire Protection
196 pages
Microsoft Word - Plumbing & Fire Fighting Design & Construction - IPC & NFPA - Online Training Course
PDF
100% (1)
Microsoft Word - Plumbing & Fire Fighting Design & Construction - IPC & NFPA - Online Training Course
4 pages
B713-DAC-BHM-1547-Fire Fightning System Design Basis Report (Alstom)
PDF
No ratings yet
B713-DAC-BHM-1547-Fire Fightning System Design Basis Report (Alstom)
8 pages
Fire Hose Trials
PDF
No ratings yet
Fire Hose Trials
55 pages
Fire Extinguishing System Fireking CAS FK Operating Manual
PDF
No ratings yet
Fire Extinguishing System Fireking CAS FK Operating Manual
100 pages
NAFFCOInert
PDF
100% (1)
NAFFCOInert
18 pages
Inspection Form - Fire Fighting and Fire Alarm
PDF
No ratings yet
Inspection Form - Fire Fighting and Fire Alarm
1 page
Schematic Diagram For Panel-2 (Utility Building) : Addressable Fire Alarm System Drawing Project Name: Ca Knitwear LTD
PDF
No ratings yet
Schematic Diagram For Panel-2 (Utility Building) : Addressable Fire Alarm System Drawing Project Name: Ca Knitwear LTD
1 page
3.1 EX5590WEG Motor
PDF
No ratings yet
3.1 EX5590WEG Motor
3 pages
Chemori_227
PDF
No ratings yet
Chemori_227
12 pages
Ochure
PDF
No ratings yet
Ochure
8 pages
MX 200 Fire Extinguishing Systems
PDF
No ratings yet
MX 200 Fire Extinguishing Systems
4 pages
Model SW-20 and SW-24 - 11.2 K-Factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description
PDF
No ratings yet
Model SW-20 and SW-24 - 11.2 K-Factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description
6 pages
Sprinkler Systems: Code Review in High-Rise Buildings Use: L.T. Wong H.W. Chong and W.K. Chow
PDF
No ratings yet
Sprinkler Systems: Code Review in High-Rise Buildings Use: L.T. Wong H.W. Chong and W.K. Chow
12 pages
AVK Air Release Valves
PDF
No ratings yet
AVK Air Release Valves
12 pages
Uniform Building Negeri Sembilan By-Laws 1986 (2007)
PDF
100% (1)
Uniform Building Negeri Sembilan By-Laws 1986 (2007)
199 pages
GVI-flow Meter
PDF
No ratings yet
GVI-flow Meter
12 pages
Vortex Inhibitor
PDF
No ratings yet
Vortex Inhibitor
1 page
2-Wire Photoelectric Duct Smoke Detector
PDF
No ratings yet
2-Wire Photoelectric Duct Smoke Detector
4 pages
Motorized Smoke Fire Damper
PDF
No ratings yet
Motorized Smoke Fire Damper
5 pages