IPS-MEHTALIA PVT. LTD.
Consulting Engineers . Construction Management . Commissioning & Qualification
B101-109, 1st Floor, Kailash Vaibhav Industrial Estate, Vikhroli (W), Mumbai – 400 079
DOCUMENT NO. IPS-MBD19084-IN-528
DATA SHEET
OF
TANK WEIGHING SYSTEM (LOAD CELL)
KANSAI NEROLAC PAINTS LTD
Project:- Emulsion Resin Production Ltd
Location:- Amritsar , Punjab
0 13-May-20 For Engineering SDH SNS SPK
Rev Date Description Made Chkd by Apd by
Entire Specification SPECIFICATION ISSUED FOR
Issued this Revision In-house Review Purchase
Revised Pages Only Client Approval Construction
Issued this Revision Enquiry Engineering
This document has been prepared for the above project or named part thereof and should not be relied upon or used for any other project without prior written consent from IPS-
Mehtalia Pvt. Ltd. IPS-Mehtalia Pvt. Ltd. accepts no responsibility or liability for the consequence of this document being used for a purpose other than the purposes for which it
was commissioned. Any person using or relying on the document for such other purpose agrees, and will by such use or reliance be taken to confirm his agreement to indemnify
IPS-Mehtalia Pvt. Ltd. for all loss or damage resulting there from. IPS-Mehtalia Pvt. Ltd.accepts no responsibility or liability for this document to any party other than the person
by whom it was commissioned.
COVER PAGE
IPS-MEHTALIA PVT. LTD. Client Kansai Nerolac
Consulting Engineers . Construction Management . Commissioning & Qualification Project No. MBD19084
B101-109, 1st Floor, Kailash Vaibhav Industrial Estate, Vikhroli (W), Mumbai – 400 079 Made/App SDH/SNS/SPK
Document Title: Data sheet of Tank Mounted Weighing system (Load Cell) Rev 0
Document No.: IPS-MBD19084-IN-528 Date 13-May-20
Weighing system (Load Cell)
1 Tag Number RFS
2 P & ID Number RFS
General 3 Service RFS
4 Application Weight Measurement of Tank
5 Make RFS
6 Model No. STS
7 Fluid/ Fluid State RFS
Service Condition
8 Tare Weight (Kg) RFS
9 Gross Weight (Kg) RFS
10 Batch Weight (Kg) RFS
11 Piping - Direct/ Flexible Flexible Hose / Flexible bellow
12 Dynamic Influence Agitaor (RFS)
Hermetically Sealed , Single / Double Shear Beam type / Compression type Load Cell as
13 Type
per RFS (IP 68)
14 Number of Load Cells RFS
15 Load Cell Capacity(Safe / Ultimate) STS
16 Excitation Voltage STS
17 Load Cell Output (mV / V) STS
18 Temp. Coefficient on Output ( % Load / OC ) STS
19 Operating Temp. Range RFS
Load Cell
20 Enclosure Classification IP-68 Hermeticlly sealed
21 Cable Length NOTE 9
22 Shock Overload STS
23 Static Overload STS
24 Safe Overload 150% / STS
25 Ultimate Overload 300% / STS
Complete Mounting Assembly with Integral Jacking Arrangement, In-built Constrainers,
26 Mounting Assembly
Earth kit, Top & Bottom Plates. All in SS 316 Material
27 Manufacturer STS
28 Model Number STS
29 Type 2 Wire Electronic
30 Enclosure Classification RFS
31 Display LED, Indicating weight / Unit Gross & Net Weight
32 Max. Display Resolution STS
33 Character Height STS
34 Display Lens STS
35 Key Pad Required
36 Load Cell Excitation Voltage STS
Transmitter
37 Calibration Range RFS
38 Output Gross Weight , Flow Rate
39 Communication Protocol Profibus Communictaion
40 Self Calibration Required
41 Power Supply 230 V AC -/+ 10% , 50 Hz -/+ 10% , 1 Phase
42 Cable Entry 1/2" NPT
43 Mounting Bracket Required
44 System Accuracy +/- 0.1 % F.S.
45 Manufacturer STS
46 Model Number STS
47 Summing Junction Box Required
48 Enclosure Material- Junction Box Powder Coated MS
1. For Hazardous Area - Intrinsically Safe - Exia, Zone – 1 Gr. IIA / IIB,
49 Enclosure Classification- Junction Box
2. For SAFE Area - Weatherproof IP67.
Options
50 Cable Entry-Junction Box 1/2" NPT (F)
51 Load Cell Mounting Accessories RFS - Shim Pack for LUG / LEG Supported Vessels
52 Constrainer Required
53 Lift Off Protection Required
54 Cable Between Summing JB & Transmitter 12 Metres
1) STS : Supplier to Specify
2) RFS : Refer Follow Sheet
3) Vendor to highlight deviation if any, from the above specification along with technical reason for the same.
4) Vendor to submit the catalogue along with offer.
5) Cables between load cell to summing box to transmitter / indicator shall be in vendor scope of supply.
Notes
6) If required, load cell mounting kits and accessories shall be of SS304.
7) Vendor shall provide foundation plate, adapter plate with required nut,bolt & washer having material as SS304.
8) Vendor to suggest requirement if thermal pad as per specified temperature.
9) Vendor to submit Mat. Test Report, Performance Test Report, Guarantees, ATEX certificate etc. in triplicate along with delivery.
10) Vendor to submit the Instrument installation manual & G.A. Drawings in hard copies 2 set and soft copies 2 set.
IPS-MEHTALIA PVT. LTD. Client Kansai Nerolac
Consulting Engineers . Construction Management . Commissioning & Qualification Project No. MBD19084
B101-109, Kailash Vaibhav Ind. Estate, Vikhroli (W), Mumbai – 400 079 Made/App. SDH/SNS/SPK
Document Title: - Data sheet of Tank Mounted Weighing system (Load Cell) Rev 0
Document No.:- IPS-MBD19084-IN-528 Date 13-May-20
Nature of Fluid Oper.Flow Rate Q (Kg/hr)
Process
(clear Tare Weight Operating Temp of
Equipment / Fluid / material Batch Gross Weight Weighing Range Leg Type / Lug No. of Lug / Leg Liquid - 1 Liquid - 2 Area
Sr. No. Tag number P&ID No. Rev No. / viscous / (Tank Empty Lug / Leg Tank Agitator Remarks
Vessel No. Servise Weight (B) (A+B) (Kg) (Kg) type Leg / Lug Temp. (Max) Material Classification
slurry Weight) (A) (Kg) °C °C
(Kg) Min Nor Max Min Nor Max
/corrosive)
IPS-MBD19084-
1 WIC-R-4210.1 1 R-4210 Process Viscuss 8950 30000 38950 0 - 60000 Lug 4 175 80 SS 304 NA NA NA NA NA NA Yes Zone1, IIA, IIB
PR-4011
IPS-MBD19084-
2 WIC-PET4210.1 1 PET4210 Process Viscuss 6150 25000 31150 0 - 60000 Lug 4 45 25 SS 304 NA NA NA NA NA NA Yes Zone1, IIA, IIB
PR-4012
IPS-MBD19084-
3 WIC-WT4210.1 1 WT4210 Process Viscuss 2900 8000 10900 0- 12000 Lug 4 95 60 SS 304 NA NA NA NA NA NA Yes Zone1, IIA, IIB
PR-4013
IPS-MBD19084- 4
4 WIC-CT4210 1 CT4210 Process Viscuss 1600 3000 4600 0 - 6000 Lug 45 25 MS NA NA NA NA NA NA Yes Zone1, IIA, IIB
PR-4013
IPS-MBD19084-
5 WIC-PET4220.1 1 PET 4220 Process Viscuss 4500 14500 19000 0 - 25000 Lug 4 45 25 SS 304 NA NA NA NA NA NA Yes Zone1, IIA, IIB
PR-4014
IPS-MBD19084-
6 WIC-ST4205.1 1 ST4205 Process Viscuss 700 500 1200 0 - 1500 Lug 3 90 60 MS NA NA NA NA NA NA Yes Zone1, IIA, IIB
PR-4015
IPS-MBD19084-
7 WIC-T4205.1 1 T4205 Process Viscuss 8950 30000 38950 0 - 60000 Lug 4 175 80 SS 304 40000 45000 45000 NA NA NA Yes Zone1, IIA, IIB
PR-4015
IPS-MBD19084-
8 WIC-ST4215.1 1 ST4215 Process Viscuss 700 500 1200 0 - 1500 Lug 3 90 60 MS NA NA NA NA NA NA Yes Zone1, IIA, IIB
PR-4016
IPS-MBD19084-
9 WIC-T4215.1 1 T4215 Process Viscuss 8950 30000 38950 0 - 60000 Lug 4 175 80 SS 304 40000 45000 45000 NA NA NA Yes Zone1, IIA, IIB
PR-4016
IPS-MBD19084-
10 WIC-T3301.1 1 T3301 Process Clear 800 700 1500 0 - 2000 Lug 3 45 Ambeint MS 3000 5000 6000 NA NA NA Yes Zone1, IIA, IIB
PR-4017
IPS-MBD19084-
11 WIC-T3302.1 1 T3302 Process Clear 800 700 1500 0 - 2000 Lug 3 45 Ambeint MS 3000 5000 6000 NA NA NA Yes Zone1, IIA, IIB
PR-4018
IPS-MBD19084-
12 WIC-T3305.1 1 T3305 Process Clear 800 700 1500 0 - 2000 Lug 3 45 Ambeint MS 3000 5000 6000 NA NA NA Yes Zone1, IIA, IIB
PR-4019
IPS-MBD19084-
13 WIC-T3101.1 1 T3101 Process Viscuss 475 1200 1675 0 - 2000 Leg 4 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4031
IPS-MBD19084-
14 WIC-T3102.1 1 T3102 Process Viscuss 900 850 1750 0 - 2000 Leg 3 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4032
IPS-MBD19084-
15 WIC-T3103.1 1 T3103 Process Viscuss 300 300 600 0 - 1000 Leg 3 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4033
IPS-MBD19084-
16 WIC-T3104.1 1 T3104 Process Viscuss 400 700 1100 0 - 1500 Leg 3 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4034
IPS-MBD19084-
17 WIC-T3105.1 1 T3105 Process Clear 900 2400 3300 0 - 5000 Leg 4 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4035
IPS-MBD19084-
18 WIC-T3201.1 1 T3201 Process Clear 400 700 1100 0 - 1500 Leg 3 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4036
IPS-MBD19084-
19 WIC-T3202.1 1 T3202 Process Clear 400 700 1100 0 - 1500 Leg 3 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4037
IPS-MEHTALIA PVT. LTD. Client Kansai Nerolac
Consulting Engineers . Construction Management . Commissioning & Qualification Project No. MBD19084
B101-109, Kailash Vaibhav Ind. Estate, Vikhroli (W), Mumbai – 400 079 Made/App. SDH/SNS/SPK
Document Title: - Data sheet of Tank Mounted Weighing system (Load Cell) Rev 0
Document No.:- IPS-MBD19084-IN-528 Date 13-May-20
Nature of Fluid Oper.Flow Rate Q (Kg/hr)
Process
(clear Tare Weight Operating Temp of
Equipment / Fluid / material Batch Gross Weight Weighing Range Leg Type / Lug No. of Lug / Leg Liquid - 1 Liquid - 2 Area
Sr. No. Tag number P&ID No. Rev No. / viscous / (Tank Empty Lug / Leg Tank Agitator Remarks
Vessel No. Servise Weight (B) (A+B) (Kg) (Kg) type Leg / Lug Temp. (Max) Material Classification
slurry Weight) (A) (Kg) °C °C
(Kg) Min Nor Max Min Nor Max
/corrosive)
IPS-MBD19084-
20 WIC-T3203.1 1 T3203 Process Clear 850 3500 4350 0 - 6500 Leg 4 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4038
IPS-MBD19084-
21 WIC-T3204.1 1 T3204 Process Clear 400 700 1100 0 - 1500 Leg 3 45 Ambeint MS 3000 5000 6000 NA NA NA No Zone1, IIA, IIB
PR-4039
WIC-BT-REC- IPS-MBD19084-
22 1 BT-REC-301A.1 Process Viscuss 1000 1100 2100 0 - 4000 Leg 4 45 Ambeint MS NA NA NA NA NA NA Yes Zone1, IIA, IIB
301A.1 PR-4064
WIC-BT-REC- IPS-MBD19084-
23 1 BT-REC-301B.1 Process Clear 800 700 1500 0 - 2000 Leg 4 45 Ambeint MS NA NA NA NA NA NA Yes Zone1, IIA, IIB
301B.1 PR-4064
WIC-CT-REC- IPS-MBD19084-
24 1 CT-REC-301.1 Process Viscuss 1000 1200 2200 0 - 4000 Leg 4 45 Ambeint MS NA NA NA NA NA NA Yes Zone1, IIA, IIB
301.1 PR-4064