Warman International LTD.: WPA 64A02M Issued JUNE 1985 Gland Sealed Pump

The document provides performance curves for a typical Warman International Ltd. pump, specifically the E4056 model with an open impeller design. It includes specifications such as frame ratings, impeller materials, and performance metrics for clear water, along with notes on potential adjustments for different media. The document also states that Warman reserves the right to change pump performance details without notice.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
128 views1 page

Warman International LTD.: WPA 64A02M Issued JUNE 1985 Gland Sealed Pump

The document provides performance curves for a typical Warman International Ltd. pump, specifically the E4056 model with an open impeller design. It includes specifications such as frame ratings, impeller materials, and performance metrics for clear water, along with notes on potential adjustments for different media. The document also states that Warman reserves the right to change pump performance details without notice.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

WARMAN INTERNATIONAL LTD.

TYPICAL PUMP
PERFORMANCE CURVES

PUMP IMPELLER: E4056


WPA
SIZE FRAME TYPE VANES TYPE IMPELLER MAT'L VANE ø LINER MAT'L
64A02M
D E 4 Open Metal 372 Metal/Polymer

6/4 DD EE AH ISSUED
Q R
GLAND SEALED PUMP JUNE 1985
REVISION:SPHERE NOTE CHANGED & CENTRIFUGAL NOTE DELETED. GENERAL NOTE REVISED

Frame D E DD EE Q R Normal Max. Metal 1600


MIN. PASSAGE SIZE
Rating [kW] 60 120 110 225 150 300 [r/min] Polymer 1325 38
mm SPHERE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER. (To International Test Standard ISO2548 Class C) : For
media other than water, corrections must be made for density, viscosity and/or other effects of solids. WARMAN INTERNATIONAL
LTD. reserve the right to change pump performance and/or delete impellers without notice. Frame suitability must be checked for COPYRIGHT © 1998-2004
each duty and drive arrangement. Not all frame alternatives are necessarily available from each manufacturing centre. WARMAN INTERNATIONAL LTD.

H
(m)

80
LAST ISSUE:JUNE 1982

70
20%

30%

40%

1600
r/min
50%

60

55%

%
56
50 1400

%
55
BSY1156/3

8m
4m

40
6m

1200
NPSH
2m

30
Printed by Warman Performance Curves v1.00.0055 05/out/2004 (3)
REF:TEST 94:A800415:A4-P-344/345