Certificate of Accreditation
Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:
(Hereinafter called the Organization) and hereby declares that Organization is accredited
in accordance with the recognized International Standard:
ISO/IEC 17025:2017
This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system
(as outlined by the joint ISO-ILAC-IAF Communiqué dated April 2017):
Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this
certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the
Organization hereby covenants with the Accreditation body’s duty to observe and comply with the said rules.
For PJLA:
Page 1 of 19
Certificate of Accreditation: Supplement
Calidad MX, S.A. de C.V.
Av. López Mateos # 1001, Local 203 Altos, Col. 21 de Enero
Guadalupe, Nuevo León, México C.P. 67160
Contact: Alejandro Lujan Phone: (52) 818-379-2710
Dimensional
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND REFERENCE
APPROPRIATE CAPABILITY EXPRESSED STANDARDS USED
AS AN UNCERTAINTY (±)
CaliperFO 0.105 in to 24 in (7.7 + 1.1 x 10-2L) µm Mitutoyo Gage Block,
MicrometerFO 0.105 in to 24 in (5.82 x 10-1 + 6 x 10-6L) µm Grade 0
CENAM Technical Guide
Micrometer HeadsF 2.6 mm to 25.4 mm (5.76 x 10-4 + 6.1 x 10-6L) mm Gage Block Grade 0
DIN-030 CEM
Coating Thickness 20 µm to 2 600 µm (5.78 x 10-2 + 1.84 x 10-1 L) µm Defelsco Certified
GaugeFO ASTM-D7091-13
Thickness Standards
TapeFO 50 m maximum 0.1 cm Standard Tape
NOM-046-SCFI-1999
RuleFO 100 cm maximum 0.006 cm Standard Rule
Glass Microrule
NOM-040-SCFI-1994
SievesF 45 µm to 13 200 µm 0.38 µm Microscope
Glass Microrule
ASTM E11-17
16 mm to 125 mm 0.012 mm Interior Caliper
ASTM E11-17
CMMO Up to 1 000 mm (1.16 + 1 x 10-6L) µm Gage Blocks
ISO-10360-2
Height GaugesFO Up to 609.6 mm (5.51 x 10-3 + 3 x 10-6L) mm Mitutoyo Gage
Height MasterFO Up to 304.8 mm (6.21 x 10-4 + 1 x 10-6L) mm Block Grade 0
DI-008 CEM
Angle MeterFO Up to 90° 0.007° Angle Block
DI-003 CEM
Granite Surface Plates 0.05 mm 1.2 μm Repeat-O-Meter with Micro
Repeat Measurement Indicator
DI-015 CEM
Roughness TesterFO Roughness Specimen
Ra (Fixed point) 2.94 µm 0.08 µm DI-025 CEM
Ry (Fixed point) 9.3 µm 0.12 µm
Dial IndicatorFO Up to 25.4 mm (4.7 + 4 x 10-3L) μm Head Micrometer
JIS B 7503
Optical Comparator Glass Reticules
min div. 0.001 mn DI-001 CEM
LengthO
X Axis Linerity 1 mm to 200 mm (9.87 x 10-4 + 1 x 10-6L) mm
Y Axis linearity 1 mm to 200 mm (9.87 x 10-4 + 1 x 10-6L) mm
Optical Comparator Up to 90° 0.05º Angular Block
AngularityO DI-001 CEM
Dimensional
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND REFERENCE
APPROPRIATE CAPABILITY EXPRESSED STANDARDS USED
AS AN UNCERTAINTY (±)
Microscopes FO Up to 100 mm (1.51 x 10-3 + 4.9 x 10-5L) mm Glass Scale, Reticule
DI-006 CEM
Vision SystemO Up to 200 mm (1.51 x 10-3 + 4.9 x 10-5L) mm Glass Reticules
DI-006 CEM
Pin GaugeF 0.152 mm to 25.4 mm 1.2 µm Master Micrometer
DI-016 CEM
Tread Plugs Pitch 0-40 to 4-12 1.4 µm Wire with Micrometer
DiameterF ASME B1.2
Feeler GaugeF 0.03 mm to 0.9 mm 1.3 µm Micrometer Digital
JIS B 7524
Bore GaugesF 10 mm to 60 mm (6.84 x 10-4 + 8.1 x 10-6L) mm Ring Gauge Master
ASME B89.1.1.6
Optical
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND REFERENCE
APPROPRIATE CAPABILITY EXPRESSED STANDARDS USED
AS AN UNCERTAINTY (±)
ρ (λ) Spectral Color Values: White Standard Tile
ReflectanceFO CENAM Technical Guide
CIE L: 0 to 100 0.36 Units
CIE a*: -28 to 36 0.26 Units
CIE b*:
-26 to 63 0.24 Units
Spectrophotometers τ: 1 % to 95 % 0.27 % of reading Neutral density Filters,
TransmittanceFO λ: 230 nm to 700 nm 0.5 nm Holmium Oxide Glass
CENAM Technical Guide
Gloss/Specular Ceram Research Gloss and
Reflectance Semi-Gloss Standards
Angle of Incline FO 20º to 92.1º 0.5 Gloss Units ASTM D-523-14
60º to 94.9º 0.5 Gloss Units
85º to 99.8º 0.5 Gloss Units
Eν IlluminanceO 100 lux to 6 000 lux 1 % of reading Luxmeter Minolta CL-200
Light Booth NIST SP 250-37
Eν Light ColorO 60 K to 6 500 K 20 K
Light Booth
Eν Light MetersF 100 lux to 6 000 lux 2 % of reading Luxometer Minolta CL-200
CENAM Technical Guide
Chemical
MEASURED INSTRUMENT, RANGE CALIBRATION CALIBRATION
QUANTITY OR GAUGE (AND SPECIFICATION AND MEASUREMENT EQUIPMENT AND REFERENCE
WHERE APPROPRIATE) CAPABILITY EXPRESSED STANDARDS USED
AS AN UNCERTAINTY (±)
pH MetersFO 4 pH to 10 pH 0.02 pH SRM NIST Traceable,
(Buffer, 4.01, 7.01, 10.01)
CENAM Technical Guide
Conductivity Meters 84 µS/cm 1 µS/cm SRM NIST Traceable
Fixed pointsFO 1 413 µS/cm 7 µS/cm CENAM Technical
Guide
TurbidimeterFO 0.1 NTU to 100 NTU 0.5 NTU EPA Method 180.1
100 NTU to 800 NTU 5 NTU HACH Standard
Refractive IndexFO 1 ºBrix to 80 ºBrix 0.55 % of reading Sucrose Standards
OIML R-108
Mechanical
MEASURED INSTRUMENT, RANGE OR NOMINAL DEVICE CALIBRATION CALIBRATION
QUANTITY OR GAUGE SIZE AS APPROPRIATE AND MEASUREMENT EQUIPMENT AND REFERENCE
CAPABILITY EXPRESSED STANDARDS USED
AS AN UNCERTAINTY (±)
BuretteF 10 mL 14 µL Analytical Balance
25 mL 35 µL AND HR200
CENAM Technical Guide
50 mL 50 µL
Volumetric Pipettes and 1 mL 3.3 µL
PipettesF 5 mL 3.3 µL
10 mL 3.3 µL
25 mL 5.3 µL
Micropipettes and 1 µL 0.023 µL Micro Analytical Balance
PipettesF 2 µL 0.023 µL AND AD-4212B-PT
Analytical Balance
5 µL 0.059 µL AND HR200
10 µL 0.051 µL CENAM Technical Guide
20 µL 0.042 µL
50 µL 0.015 µL
100 µL 0.015 µL
200 µL 0.083 µL
500 µL 0.32 µL
1 000 µL 0.32 µL
2 000 µL 0.32 µL
Mechanical
MEASURED INSTRUMENT, RANGE OR NOMINAL DEVICE CALIBRATION CALIBRATION
QUANTITY OR GAUGE SIZE AS APPROPRIATE AND MEASUREMENT EQUIPMENT AND
CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Graduated CylinderF 25 mL 1.2 mL Analytical Balance
50 mL 1.2 mL AND HR200
OHAUS SPX2202
100 mL 1.2 mL CENAM Technical Guide
250 mL 1.2 mL
500 mL 1.2 mL
1 000 mL 1.2 mL
2 000 mL 1.2 mL
Volumetric FlaskF 10 mL 0.02 µL
25 mL 0.02 µL
50 mL 0.02 µL
100 mL 0.03 mL
250 mL 0.07 mL
500 mL 0.08 mL
1 000 mL 0.15 mL
2 000 mL 0.33 mL
ContainersF 10 L 0.34 mL
20 L 0.34 mL
200 L 1.7 mL
Pressure Gauge 1 psi to 1 000 psi 0.6 % of reading Digital Manometer
Pressure TransducerFO Ametek EPC2000
CENAM Technical Guide
1 000 psi to 10 000 psi 0.2 % of reading Digital Manometer
Adittel GP10K
CENAM Technical Guide
0.02 H20 to 280 in H20 0.02 % of reading AMETEC EPC 2000
CENAM Technical Guide
VacuumFO -14 psi to 0 psi 0.02 % of reading
Pressure Gauge
Pressure Transducer
Dynamic Viscosity 0.1 Pa∙s to 30 Pa∙s 0.58 % of reading Cannon Standard OIL
MetersFO NMX-U-038-SCFI
Kinematic Viscosity Ford 121.6 mm²/s 1.4 % of reading Cannon Standard OIL
Cup No.4FO ASTM D4212 − 16
Mechanical
MEASURED INSTRUMENT, RANGE OR NOMINAL DEVICE CALIBRATION CALIBRATION
QUANTITY OR GAUGE SIZE AS APPROPRIATE AND MEASUREMENT EQUIPMENT AND
CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Kinematic Viscosity 48.75 mm²/s 1.1 % of reading Cannon Standard OIL
Zahn Cups No. 2FO ASTM D4212 − 16
Kinematic Viscosity 42.37 mm²/s 1.1 % of reading
Zahn Cups No. 3FO
Kinematic Viscosity 32.57 mm²/s 1.1 % of reading
Zahn Cups No. 4FO
Torque Wrench 2 N∙m to 500 N∙m 1 % of reading Torque Transducer
Torque TransducerF CEDAR Mod.
DIS-IP500 500 N∙m
CENAM Technical Guide
Torque Wrench 0.1 N∙m to 15 N∙m 0.5 % of reading Torque Transducer
Torque TransducerFO CEDAR Mod.
IM-CD150M
Indirect Verifications 20 HRC to 30 HRC 0.42 HRC E18-16 Test Blocks
Hardness Tester 30 HRC to 60 HRC 0.39 HRC CENAM Technical Guide
HRCO
60 HRC to 70 HRC 0.38 HRC
Indirect Verifications 40 HRB to 60 HRB 0.38 HRB
Hardness Tester 60 HRB to 80 HRB 0.36 HRB
HRBO
80 HRB to 100 HRB 0.42 HRB
Indirect Verifications 120 HB to 300 HB 1.8 HB
Hardness Tester at 10/1 500 kgf
HBO 300 HB to 600 HB 6 HB
at 10/3 000 kgf
Direct Verification of ASTM D-2240
Durometer Hardness
TesterF
Types A, B, C, D, E, O, & 2.46 mm to 2.54 mm 3.7 µm Head Micrometer
DO
Extension at zero reading
Durometer Indentor
Spring
Types A, B, E & O 0.55 N to 9.05 N 1.4 N Electronic Balance
Types C, D & DO 0.445 N to 44.45 N 1.4 N
Thermodynamic
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Thermocouple KFO 0 ºC to 500 ºC 0.24 ºC Fluke 724, Dry Well
501 ºC to 1 100 ºC 0.24 ºC NIST 250-35
Thermocouple JFO 0 ºC to 500 ºC 0.24 ºC
501 ºC to 1 100 ºC 0.24 ºC
Thermodynamic
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND REFERENCE
APPROPRIATE CAPABILITY EXPRESSED STANDARDS USED
AS AN UNCERTAINTY (±)
RTD Pt 100 -80 ºC to 420 ºC 0.11 ºC Fluke 724 with
Dry Well, Freezer, Dry Ice
Bath Comparison
CENAM Technical Guide
Bimetallic ThermometerFO -20 ºC to 500 ºC 1.2 ºC Fluke 724, Dry Well
Temperature ControllersFO 0 ºC to 1 100 °C 0.5 ºC NIST 250-35
IR ThermometerFO 50 ºC to 500 ºC 0.64 ºC Fluke 724 Dry Block
Black Body
(Temperature Generator)
CENAM Technical Guide
Temperature Generation: -20 ºC to 0 ºC 1.4 ºC Fluke 724
Ovens, Furnaces, Muffles, 0 ºC to 25 ºC 1.4 ºC NIST 250-35
Freezers and IncubatorsFO
25 ºC to 100 ºC 1.5 ºC
100 ºC to 450 ºC 1.7 ºC
450 ºC to 900 ºC 1.9 ºC
Relative HumidityFO 11.3 % RH 1.5 % RH Saturated Salt Solution
35 % RH 1.5 % RH OIML R-121
95 % RH 1.5 % RH
Electrical
MEASURED INSTRUMENT, RANGE OR NOMINAL DEVICE CALIBRATION CALIBRATION
QUANTITY OR GAUGE SIZE AS APPROPRIATE AND MEASUREMENT EQUIPMENT AND REFERENCE
CAPABILITY EXPRESSED STANDARDS USED
AS AN UNCERTAINTY (±)
Equipment to Measure 0.1 Ω to 1 Ω 0.0026 Ω Process Calibrator
ResistanceFO 1 Ω to 2 Ω 0.002 4 Ω Fluke 743 B
CENAM Technical Guide
2 Ω to 5 Ω 0.002 5 Ω
Electrical
MEASURED INSTRUMENT, RANGE OR NOMINAL DEVICE CALIBRATION CALIBRATION
QUANTITY OR GAUGE SIZE AS APPROPRIATE AND MEASUREMENT EQUIPMENT AND
CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Equipment to Measure 5 Ω to 10 Ω 0.002 4 Ω Process Calibrator
ResistanceFO 10 Ω to 20 Ω 0.004 9 Ω Fluke743 B
CENAM Technical Guide
20 Ω to 50 Ω 0.007 Ω
50 Ω to 100 Ω 0.039 Ω
100 Ω to 200 Ω 0.017 Ω
200 Ω to 500 Ω 0.018 Ω
500 Ω to 1 000 Ω 0.9 Ω
Equipment to Output 100 mV to 1 V 0.001 8 V Fluke 5500A
DC VoltageFO 1 V to 10 V 0.002 V Multimeter
CENAM Technical Guide
10 V to 100 V 0.003 V
100 V to 1 000 V 0.048 V
Equipment to Output 0.001 V to 750 V 0.13 V
AC Voltage
At the listed frequencies
50 Hz to 1 kHzFO
Equipment to Output 0.01 A to 3 A 0.001 3 A
AC Current 3 A to 10 A 0.024 A
At the listed frequencies
10 Hz to 900 HzFO
Equipment to output 0.000 01 mA to 9.999 9 mA 0.001 9 mA
DC CurrentFO 10 mA to 99.999 mA 0.006 8 mA
100 mA to 1 A 0.006 9 mA
1 A to 3 A 0.000 7 A
3 A to 10 A 0.006 8 A
Equipment to Output Up to 100 Ω 0.01 % of reading + 0.004 range Agilent Multimeter
ResistanceFO 100 Ω to 1 kΩ 0.01 % of reading + 0.001 range 34401A
Procedure EL-024
1 kΩ to 10 kΩ 0.01 % of reading + 0.001 range Procedure EL-025
10 kΩ to 100 kΩ 0.01 % of reading + 0.001 range
100 kΩ to 1 MΩ 0.01 % of reading + 0.001 range
1 MΩ to 10 MΩ 0.04 % of reading + 0.001 range
10 MΩ to 100 MΩ 0.8 % of reading + 0.01 range
Electrical
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Equipment to Measure 330 Ω to 1.099 99 kΩ 0.009 % of reading + 0.06 Ω Fluke 5500A
ResistanceFO 1.1 kΩ to 3.299 99 kΩ 0.009 % of reading + 0.06 Ω Multicalibrator
CENAM Technical Guide
3.3 kΩ to 10.999 9 kΩ 0.009 % of reading + 0.6 Ω
11 kΩ to 32.999 9 kΩ 0.009 % of reading + 0.6 Ω
33 kΩ to 109.999 kΩ 0.011 % of reading + 6 Ω
110 kΩ to 329.999 kΩ 0.012 % of reading + 6 Ω
330 kΩ to 1.099 99 MΩ 0.015 % of reading + 55 Ω
1.1 MΩ to 3.299 99 MΩ 0.015 % of reading + 55 Ω
3.3 MΩ to 10.999 9 MΩ 0.06 % of reading + 550 Ω
11 MΩ to 32.999 9 MΩ 0.1 % of reading + 550 Ω
33 MΩ to 109.999 MΩ 0.5 % of reading + 5 500 Ω
110 MΩ to 330 MΩ 0.5 % of reading + 16 500 Ω
Equipment to Measure
AC Voltage
At the listed frequenciesFO
10 Hz to 45 Hz 1 mV to 32.999 mV 0.35 % of reading + 20 μV
45 kHz to 10 kHz 1 mV to 32.999 mV 0.15 % of reading + 20 μV
10 kHz to 20 kHz 1 mV to 32.999 mV 0.2 % of reading + 20 μV
20 kHz to 50 kHz 1 mV to 32.999 mV 0.25 % of reading + 20 μV
50 kHz to 100 kHz 1 mV to 32.999 mV 0.35 % of reading + 33 μV
100 kHz to 500 kHz 1 mV to 32.999 mV 1 % of reading + 60 μV
Equipment to Measure
AC Voltage
At the listed frequenciesFO
10 Hz to 45 Hz 33 mV to 329.999 mV 0.25 % of reading + 50 μV
45 kHz to 10 kHz 33 mV to 329.999 mV 0.05 % of reading + 20 μV
10 kHz to 20 kHz 33 mV to 329.999 mV 0.1 % of reading + 20 μV
20 kHz to 50 kHz 33 mV to 329.999 mV 0.16 % of reading + 40 μV
50 kHz to 100 kHz 33 mV to 329.999 mV 0.24 % of reading + 170 μV
100 kHz to 500 kHz 33 mV to 329.999 mV 0.7 % of reading + 330 μV
Equipment to Measure
AC Voltage
At the listed frequenciesFO
10 Hz to 45 Hz 0.33 V to 3.299 99 V 0.15 % of reading + 250 μV
45 kHz to 10 kHz 0.33 V to 3.299 99 V 0.03 % of reading + 60 μV
Electrical
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Equipment to Measure Fluke 5500A
AC Voltage Multicalibrator
At the listed frequenciesFO CENAM Technical Guide
10 kHz to 20 kHz 0.33 V to 3.299 99 V 0.08 % of reading + 60 μV
20 kHz to 50 kHz 0.33 V to 3.299 99 V 0.14 % of reading + 300 μV
50 kHz to 100 kHz 0.33 V to 3.299 99 V 0.24 % of reading + 1 700 μV
100 kHz to 500 kHz 0.33 V to 3.299 99 V 0.5 % of reading + 3 300 μV
Equipment to Measure
AC Voltage
At the listed frequenciesFO
10 Hz to 45 Hz 3.3 V to 32.999 9 V 0.15 % of reading + 2 500 μV
45 kHz to 10 kHz 3.3 V to 32.999 9 V 0.04 % of reading + 600 μV
10 kHz to 20 kHz 3.3 V to 32.999 9 V 0.08 % of reading + 2 600 μV
20 kHz to 50 kHz 3.3 V to 32.999 9 V 0.19 % of reading + 5 000 μV
50 kHz to 100 kHz 3.3 V to 32.999 9 V 0.24 % of reading + 17 000 μV
Equipment to Measure
AC Voltage
At the listed frequenciesFO
45 Hz to 1 kHz 33 V to 329.999 9 V 0.05 % of reading + 6 600 μV
1 kHz to 10 kHz 33 V to 329.999 9 V 0.08 % of reading + 15 000 μV
10 kHz to 20 kHz 33 V to 329.999 9 V 0.09 % of reading + 33 000 μV
Equipment to Measure
AC Voltage
At the listed frequenciesFO
45 Hz to 1 kHz 330 V to 1 020 V 0.05 % of reading + 80 000 μV
1 kHz to 5 kHz 330 V to 1 020 V 0.2 % of reading + 100 000 μV
5 kHz to 10 kHz 330 V to 1 020 V 0.2 % of reading + 500 000 μV
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz 0.029 mA to 0.329 99 mA 0.25 % of reading + 0.15 μA
20 Hz to 45 Hz 0.029 mA to 0.329 99 mA 0.13 % of reading + 0.15 μA
45 Hz to 1 kHz 0.029 mA to 0.329 99 mA 0.13 % of reading + 0.25 μA
1 kHz to 5 kHz 0.029 mA to 0.329 99 mA 0.4 % of reading + 0.15 μA
5 kHz to 10 kHz 0.029 mA to 0.329 99 mA 1.3 % of reading + 0.15 μa
Electrical
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Equipment to Measure Fluke 5500A
AC Current Multicalibrator
At the listed frequenciesFO CENAM Technical Guide
10 Hz to 20 Hz 0.33 mA to 3.299 9 mA 0.2 % of reading + 0.3 μA
20 Hz to 45 Hz 0.33 mA to 3.299 9 mA 0.1 % of reading + 0.3 μA
45Hz to 1 kHz 0.33 mA to 3.299 9 mA 0.1 % of reading + 0.3 μA
1 kHz to 5 kHz 0.33 mA to 3.299 9 mA 0.2 % of reading + 0.3 μA
5 kHz to 10 kHz 0.33 mA to 3.299 9 mA 0.6 % of reading + 0.3 μa
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz 3.3 mA to 32.999 9 mA 0.2 % of reading + 3 μA
20 Hz to 45 Hz 3.3 mA to 32.999 9 mA 0.1 % of reading + 3 μA
45Hz to 1 kHz 3.3 mA to 32.999 9 mA 0.09 % of reading + 3 μA
1 kHz to 5 kHz 3.3 mA to 32.999 9 mA 0.2 % of reading + 3 μA
5 kHz to 10 kHz 3.3 mA to 32.999 9 mA 0.6 % of reading + 3 μa
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz 33 mA to 329.999 mA 0.2 % of reading + 30 μA
20 Hz to 45 Hz 33 mA to 329.999 mA 0.1 % of reading + 30 μA
45Hz to 1 kHz 33 mA to 329.999 mA 0.09 % of reading + 30 μA
1 kHz to 5 kHz 33 mA to 329.999 mA 0.2 % of reading + 30 μA
5 kHz to 10 kHz 33 mA to 329.999 mA 0.6 % of reading + 30 μa
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 45 Hz 0.33 A to 2.199 99 A 0.2 % of reading + 300 μA
45 Hz to 1 kHz 0.33 A to 2.199 99 A 0.1 % of reading + 300 μA
1 kHz to 5 kHz 0.33 A to 2.199 99 A 0.75 % of reading + 300 μA
Equipment to Measure
AC Current
At the listed frequenciesFO
45 Hz to 65 Hz 2.2 A to 11 A 0.06 % of reading + 2 000 μA
65 Hz to 500 Hz 2.2 A to 11 A 0.1 % of reading + 2 000 μA
500 Hz to 1 kHz 2.2 A to 11 A 0.33 % of reading + 2 000 μA
1. The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of
accreditation represents the smallest measurement uncertainty attainable by the laboratory when performing
a more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is typically
expressed at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual
measurement uncertainty associated with a specific calibration performed by the laboratory will typically
be larger than the CMC for the same calibration since capability and performance of the device being
calibrated and the conditions related to the calibration may reasonably be expected to deviate from ideal to
some degree.