Product: RSPE35-24044O7T99-EKKV999HHPE2A07.
1
Configurator: RSPE -Rail Switch Power Enhanced
Configurator Description
The compact and extremely robust RSPE switches comprise a basic device with eight twisted pair ports and four combination ports that support Fast Ethernet
or Gigabit Ethernet. The basic device – optionally available with the HSR (High-Availability Seamless Redundancy) and PRP (Parallel Redundancy Protocol)
uninterruptible redundancy protocols, plus precise time synchronization in accordance with IEEE 1588 v2 - can be extended to provide up to 28 ports by adding
two media modules.
Technical Specifications
Product description
Description Managed Fast/Gigabit Industrial Ethernet Switch, fanless design Enhanced (PRP, Fast MRP, HSR, DLR, NAT, TSN)
Port type and quantity Ports in total up to 28 Base unit: 4 x Fast/Gigbabit Ethernet Combo ports plus 8 x Fast Ethernet TX ports expandable with two slots for media modules with 8 Fast Ethernet ports each
More Interfaces
Power supply/signaling 2 x plug-in terminal block 3-pins, 1x plug-in terminal block 2-pins
contact
V.24 interface 1 x RJ11 socket
SD-card slot 1 x SD card slot to connect the auto configuration adapter ACA31
USB interface 1 x USB to connect auto-configuration adapter ACA22-USB
Network size - length of cable
Twisted pair (TP) 0-100 m
Single mode fiber (SM) see SFP modules
9/125 µm
Single mode fiber (LH)
9/125 µm (long haul see SFP modules
transceiver)
Multimode fiber (MM) see SFP modules
50/125 µm
Multimode fiber (MM) see SFP modules
62.5/125 µm
Network size - cascadibility
Line - / star topology any
Power requirements
Operating Voltage 2 x 60-250 V DC (48-320 V DC) and 110-230 V AC (88-265 V AC)
Power consumption maximum 36W depending on fiber port count
Software
Independent VLAN Learning, Fast Aging, Static Unicast/Multicast Address Entries, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue
Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), VLAN Unaware
Switching Mode, Voice VLAN, IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol
(MMRP), Multiple Registration Protocol (MRP), Password change on first login IP Ingress DiffServ Classification and Policing, Protocol-based VLAN, GARP VLAN Registration Protocol
(GVRP), MAC-based VLAN, IP subnet-based VLAN, GARP Multicast Registration Protocol (GMRP)
Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), RSTP 802.1D-2004 (IEC62439-1), RSTP Guards HIPER-Ring (Ring Switch), HIPER-Ring
Redundancy over Link Aggregation, MRP over Link Aggregation, Redundant Network Coupling, Sub Ring Manager, MSTP (802.1Q) Fast MRP (IEC62439-2), High Availability Seamless
Redundancy Protocol (HSR) (IEC62439-3), Parallel Redundancy Protocol (PRP) (IEC62439-3)
Management Dual Software Image Support, TFTP, SFTP. SCP. LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet DNS Client
Management Address Conflict Detection, MAC Notification, Signal Contact, Device Status Indication, TCPDump, LEDs, Syslog, Persistent Logging on ACA, Port Monitoring with
Auto-Disable, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed and Duplex Monitoring, RMON (1,2,3,9), Port Mirroring 1:1, Port Mirroring 8:1, Port
Diagnostics
Mirroring N:1, System Information, Self-Tests on Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump, Snapshot Configuration Feature Email
Notification, RSPAN, SFLOW, VLAN Mirroring
Automatic Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), BOOTP/DHCP Client with Auto-Configuration, DHCP Server: per Port, DHCP
Configuration Server: Pools per VLAN, AutoConfiguration Adapter ACA21/22 (USB), AutoConfiguration Adapter ACA31 (SD card), HiDiscovery, DHCP Relay with Option 82, Command Line
Interface (CLI), CLI Scripting, Full-featured MIB Support, Web-based Management, Context-sensitive Help
MAC-based Port Security, Port-based Access Control with 802.1X, Guest/unauthenticated VLAN, Integrated Authentication Server (IAS), RADIUS VLAN Assignment, Denial-of-Service
Prevention, VLAN-based ACL, Ingress VLAN-based ACL, Basic ACL, Access to Management restricted by VLAN, Device Security Indication, Audit Trail, CLI Logging, HTTPS
Security Certificate Management, Restricted Management Access, Appropriate Use Banner, Configurable Password Policy, Configurable Number of Login Attempts, SNMP Logging, Multiple
Privilege Levels, Local User Management, Remote Authentication via RADIUS, User Account Locking RADIUS Policy Assignment, Multi-Client Authentication per Port, MAC
Authentication Bypass, DHCP Snooping, Dynamic ARP Inspection, LDAP, Ingress MAC-based ACL, Ingress IPv4-based ACL, Time-based ACL, ACL Flow-based Limiting
Time synchronisation PTPv2 Transparent Clock two-step, PTPv2 Boundary Clock, Buffered Real Time Clock, SNTP Client, SNTP Server
Industrial Profiles EtherNet/IP Protocol, IEC61850 Protocol (MMS Server, Switch Model), ModbusTCP, PROFINET IO Protocol
Miscellaneous Manual Cable Crossing, Port Power Down
Ambient conditions
MTBF (Telecordia 702 592 h
SR-332 Issue 3) @ 25°C
Operating temperature -40-+70 °C
Note IEC 60068-2-2 Dry Heat Test +85°C 16 Hours
Storage/transport -40-+85 °C
temperature
Relative humidity 10-95 %
(non-condensing)
Protective paint on PCB Yes (conformal coating)
Mechanical construction
Dimensions (WxHxD) 217 mm x 164 mm x 120 mm
Weight 2500 g
Mounting DIN rail
Protection class IP20
Mechanical stability
IEC 60068-2-6 vibration 1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks
EMC interference immunity
EN 61000-4-2
electrostatic discharge 8 kV contact discharge, 15 kV air discharge
(ESD)
EN 61000-4-3 35 V/m (80-2700 MHz); 1 kHz, 80% AM
electromagnetic field
EN 61000-4-4 fast 4 kV power line, 4 kV data line
transients (burst)
EN 61000-4-5 surge power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line IEEE1613: power line 5 kV (line/earth)
voltage
EN 61000-4-6 3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
Conducted Immunity
EN 61000-4-16 mains 30 V, 50 Hz continous; 300 V, 50 Hz 1 s
frequency voltage
EMC emitted immunity
EN 55022 EN 55032 Class A
FCC CFR47 Part 15 FCC 47CFR Part 15, Class A
Approvals
Basis Standard CE, FCC, RCM, EN61131
Substation IEC61850-3, IEEE1613
Scope of delivery and accessories
Accessories Rail Power Supply RPS 80/120, Terminal Cable, Network management Industrial HiVision, ACA22, ACA31, SFP
Scope of delivery Device, terminal blocks , General safety instructions
© 2020 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.