MANN+HUMMEL
FILTER CALCULATION SYSTEM
CALCULATION RESULTS Date: 2019/01/14 V 5.8
Customer: KPCL Filter Type: EP 800
Project: 0 without secondary element
Dust Concentration: 1.0 [mg/m³] Flow Rate: 31.20 [m³/min]
∆p Air Intake Duct: - [mbar] Initial Restriction: 31.0 [mbar]
∆p Clean Gas Pipe: - [mbar] negative pressure dust port: [mbar]
Ambient Temperature: 20 [°C] Final Restriction: 65.0 [mbar]
Ambient Pressure: 1,013 [mbar] Dust Capacity: 19,089 [g]
Scavenge Flow: - [%] Filter Life: 10,197.3 [h]
Test dust PTI coarse Filter Area: 17.09 [m²]
Initial Separation Efficiency* 99.65 [%]
Total Separation Efficiency* 99.97 [%]
* at nominal flow rate, test dust acc. ISO 12103-1, filtration data acc. ISO 5011
50
FLOW RESTRICTION [mbar]
40
30
20
10
0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0
FLOW RATE [m³/min]
80
70
FLOW RESTRICTION [mbar]
60
50
40
30
20
10
0
0.0 5,000.0 10,000.0 15,000.0 20,000.0 25,000.0
DUST CAPACITY [g]
Source: M+H FilterCalcSystem FCS Page 1 of 2 printed at:14-01-2019
This document is the property of MANN+HUMMEL GmbH - protection notice according to ISO 16016 must be observed.
MANN+HUMMEL
FILTER CALCULATION SYSTEM
CALCULATION RESULTS Date: 2019/01/14 V 5.8
Customer: KPCL Filter Type: EP 800
Project: 0 without secondary element
Dust Concentration: 1.0 [mg/m³] Flow Rate: 31.20 [m³/min]
∆p Air Intake Duct: - [mbar] Initial Restriction: 31.0 [mbar]
∆p Clean Gas Pipe: - [mbar] negative pressure dust port: [mbar]
Ambient Temperature: 20 [°C] Final Restriction: 65.0 [mbar]
Ambient Pressure: 1,013 [mbar] Dust Capacity: 19,089 [g]
Scavenge Flow: - [%] Filter Life: 10,197.3 [h]
Test dust PTI coarse Filter Area: 17.09 [m²]
Initial Separation Efficiency* 99.65 [%]
Total Separation Efficiency* 99.97 [%]
* at nominal flow rate, test dust acc. ISO 12103-1, filtration data acc. ISO 5011
60 35000
30000
50
FLOW RESTRICTION [mbar]
25000
40
FILTER LIFE [hrs]
20000
30
15000
20
10000
10
5000
0 0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0
FLOW RATE [m³/min]
Notes:
This document is the property of MANN+HUMMEL GmbH - protection notice according to ISO 16016 must be observed.
Source: M+H FilterCalcSystem FCS Page 2 of 2 printed at:14-01-2019