| Lenze Antriebstechnik |26.04.2022|14:48|-001-|


------------------------------------------------------------------------------

Drive: ECSxS Speed&Torque


Software version: 9.2

Software EKZ Basic Unit: 33S93CAI_60000


Inverter description: EnECSSpe_A100.pdb
--------------------------------------------------------------------------------
Compare parameter: Drive parameter value/Factory setting

0002/000 Parameter load


load PS1 / load default
0040/000 controller enable
ctrl inhibit / ctrl enable
0051/000 DIS: actual motor speed
-2 rpm / 0 rpm
0053/000 DIS: actual DC voltage
193 V / 0 V
0055/001 Actual motor phase current Iu
-0.01 A / 0.00 A
0055/002 DIS: Actual motor phase current Iv
-0.01 A / 0.00 A
0055/003 DIS: Actual motor phase current Iw
0.02 A / 0.00 A
0057/000 DIS: max. torque
9.4 Nm / 0.0 Nm
0059/000 DIS: motor pole no.
3 / 1
0060/000 DIS: motor rotor position
1453 / 0
0061/000 DIS: heatsink temperature
24 °C / 0 °C
0062/000 DIS: interior temperature
40 °C / 0 °C
0063/000 DIS: motor temperature
48 °C / 0 °C
0065/000 DIS: U24 external
23.9 V / 0.0 V
0081/000 motor power
3.20 kW / 1.00 kW
0093/000 DIS: drive identification
ECSxA008C4 / invalid power stage
0099/000 DIS: SW version operating system
9.2 / 1.0
0135/000 control word
0200h hex / 0000h hex
0136/001 DIS: control word C135
0200h hex / 0000h hex
0150/000 DIS: status word DCTRL
03C2h hex / 0000h hex
0155/000 DIS: statusword 2
0038h hex / 0000h hex
0168/002 DIS: fail number old1
LU-Message / No Error
0168/003 DIS: fail number old2
H07-TRIP / No Error
0168/004 DIS: fail number old3
LU-Message / No Error
0168/005 DIS: fail number old4
OH3-TRIP / No Error
0168/006 DIS: fail number old5
Sd2-TRIP / No Error
------------------------------------------------------------------------------
| Lenze Antriebstechnik |26.04.2022|14:48|-002-|
------------------------------------------------------------------------------

0168/007 DIS: fail number old6


OH3-TRIP / No Error
0168/008 DIS: fail number old7
Sd2-TRIP / No Error
0169/002 DIS: failtime old1
29431925 s / 0 s
0169/003 DIS: failtime old2
29431907 s / 0 s
0169/004 DIS: failtime old3
29430727 s / 0 s
0169/005 DIS: failtime old4
29427714 s / 0 s
0169/006 DIS: failtime old5
29427713 s / 0 s
0169/007 DIS: failtime old6
29427710 s / 0 s
0169/008 DIS: failtime old7
29427709 s / 0 s
0170/002 DIS: Fail counter old1
1 / 0
0170/003 DIS: Fail counter old2
7 / 0
0170/004 DIS: Fail counter old3
6 / 0
0170/005 DIS: Fail counter old4
1 / 0
0170/006 DIS: Fail counter old5
1 / 0
0170/007 DIS: Fail counter old6
1 / 0
0170/008 DIS: Fail counter old7
1 / 0
0178/000 DIS: operation timer
7286934 s / 0 s
0179/000 DIS: mains on timer
29432125 s / 0 s
0183/000 DIS: drive diagnostic
CINH int 1 / ok
0200/000 DIS: os-software Id
33S93CAI_92000 /
0201/000 DIS: os-software date
May 21 2014 10:20:14 /
0203/000 DIS: komm.-no.
000007557874 /
0204/000 DIS: serial-no.
1 / 0
0205/000 DIS: PLC target ID
15117 / 0
0206/000 DIS: produkt date
05/04/16 /
0207/000 DIS: download info 1
/
0208/000 DIS: download info 2
/
0209/000 DIS: download info 3
/
0349/001 address (DIP-switch)
4 / 0
0349/002 baudrate (DIP-switch)
2 / 0
------------------------------------------------------------------------------
| Lenze Antriebstechnik |26.04.2022|14:48|-003-|
------------------------------------------------------------------------------

0350/000 CAN node address


4 / 1
0351/000 CAN baudrate
125kbit/s / 500kbit/s
0354/001 CAN1 IN Adress (Adr. + 384 = Identifier)
132 / 129
0354/002 CAN1 OUT Adress (Adr. + 384 = Identifier)
4 / 1
0354/003 CAN2 IN Adress (Adr. + 384 = Identifier)
260 / 257
0354/004 CAN2 OUT Adress (Adr. + 384 = Identifier)
261 / 258
0354/005 CAN3 IN Adress (Adr. + 384 = Identifier)
388 / 385
0354/006 CAN3 OUT Adress (Adr. + 384 = Identifier)
389 / 386
0355/001 DIS: CAN1 IN Identifier
516 / 0
0355/002 DIS: CAN1 OUT Identifier
388 / 0
0355/003 DIS: CAN2 IN Identifier
644 / 0
0355/004 DIS: CAN2 OUT Identifier
645 / 0
0355/005 DIS: CAN3 IN Identifier
772 / 0
0355/006 DIS: CAN3 OUT Identifier
773 / 0
0359/000 DIS: CAN bus state
pre-operat. / operational
0360/001 DIS: CAN Number of OUT
2827 / 0
0360/002 DIS: CAN Number of IN
2827 / 0
0360/006 DIS: CAN Number of POUT1
2827 / 0
0360/011 DIS: CAN Number of PIN1
2827 / 0
0361/001 DIS: CAN Busload OUT
13.62 % / 0.00 %
0361/002 DIS: CAN Busload IN
13.62 % / 0.00 %
0361/006 DIS: CAN Busload POUT1
13.62 % / 0.00 %
0361/011 DIS: CAN Busload PIN1
13.62 % / 0.00 %
0362/000 CAN sync cycle
0 ms / 1 ms
0384/000 errorconf. life guarding event
off / trip
0420/000 encoder constant input (X8)
512 incr/rev / 1024 incr/rev
0443/000 DIS: DIGIN
40h / 00h
0506/000 select RAM-block
1 / 0
0577/000 Vp field weak CTRL
0.10 / 1.00
0578/000 Tn field weak CTRL
3.0 ms / 4.0 ms
------------------------------------------------------------------------------
| Lenze Antriebstechnik |26.04.2022|14:48|-004-|
------------------------------------------------------------------------------

0746/001 Oscilloscope
8 / 0
0746/002 Oscilloscope
16384 / 0
0746/003 Oscilloscope
2000 / 0
0746/004 Oscilloscope
65535 / 0
0746/009 Oscilloscope
65535 / 0
0746/017 Oscilloscope
119086 / 0
0878/001 DIS: DCTRL DCTRL-CInh1
1 / 0
0906/003 DIS: MCTRL lower torque limit
-100.00 % / 0.00 %
0906/004 DIS: MCTRL upper torque limit
100.00 % / 0.00 %
0906/005 DIS: MCTRL limit pos. CTRL
100.00 % / 0.00 %
0906/007 DIS: MCTRL field weak
100.00 % / 0.00 %
0906/009 DIS: MCTRL adapt. pos.-CTRL
100.00 % / 0.00 %
0907/001 DIS: MCTRL Position CTRL on/off
1 / 0
1122/000 syncronisation phase
0.460 ms / 0.000 ms
2108/000 PLC program Start/Stop/Reset
PLC stop / no function
2111/000 DIS: SW Id PLC program
03052004140005 / 0.000000
2113/000 DIS: project name
ECSSpe_A100 / 0.000000
2130/000 DIS: add-data filename (Apl.-Flash)
no Add-Data / 0.000000
2131/000 DIS: add-data filetype (Apl.-Flash)
65535 / 0
2356/001 XCAN boot up delay
0 ms / 3000 ms
2357/004 XCAN monitoring time bus-off CE0
3000 ms / 1 ms
2375/002 XCAN2 Tx Mode
no response to sync / response to sync
2375/003 XCAN3 Tx Mode
no response to sync / response to sync
2455/001 DIS: CANaux1 IN Identifier
513 / 0
2455/002 DIS: CANaux1 OUT Identifier
385 / 0
2455/003 DIS: CANaux2 IN Identifier
641 / 0
2455/004 DIS: CANaux2 OUT Identifier
642 / 0
2455/005 DIS: CANaux3 IN Identifier
769 / 0
2455/006 DIS: CANaux3 OUT Identifier
770 / 0
2459/000 DIS: CANaux bus state
warning / operational
------------------------------------------------------------------------------
| Lenze Antriebstechnik |26.04.2022|14:48|-005-|
------------------------------------------------------------------------------

3999/000 Version
10000 / 0
6331/001 DCTRL-AIF1Ctrl
AIF1In-DctrlCtrl / FIXED 0%
6331/002 DCTRL-CAN1Ctrl
CAN1In-DctrlCtrl / FIXED 0%
6371/002 DigOut-Relais
SPEED-BRK.NegOut / FIXED 0 / FALSE
7411/001 SPEED-RLQ.Cw
DigIn-In1 / FIXED 0 / FALSE
7411/002 SPEED-RLQ.CCw
DigIn-In2 / FIXED 0 / FALSE
7411/003 SPEED-NSET.Jog1
DigIn-In3 / FIXED 0 / FALSE
7411/010 SPEED-BRK.SetBrake
DigIn-In4 / FIXED 0 / FALSE
7411/012 SPEED-MCTRL.ILoad
SPEED-BRK.MStore / FIXED 0 / FALSE
7411/017 SPEED-QSPSet1
DCTRL-QspIn / FIXED 0 / FALSE
7411/018 SPEED-QSPSet2
SPEED-BRK.SetQSP / FIXED 0 / FALSE
7431/001 SPEED-NSET.NSet
AIn1-Out / FIXED 0%
7431/003 SPEED-MCTRL.NegLoMLim
FCODE-C0472/3 / FIXED 0%
7431/004 SPEED-MCTRL.HiMLim
FCODE-C0472/3 / FIXED 0%
7431/006 SPEED-MCTRL.FldWeak
FIXED 100% / FIXED 0%
7431/007 SPEED-MCTRL.NAdapt
FIXED 100% / FIXED 0%
7431/008 SPEED-MCTRL.ISet
SPEED-BRK.MSetOut / FIXED 0%
7431/009 SPEED-BRK.SpeedThreshold
FCODE-C0472/10 / FIXED 0%
7431/010 SPEED-BRK.Sign
FCODE-C0472/11 / FIXED 0%