LaserGas™ II Compact

All Rights Reserved, Copyright © May 2015, NEO Monitors AS


NEO Monitors LaserGas™ is using Tuneable Diode Laser Absorption­­­Spectroscopy­­(TDLAS) i.e a non-contact optical measure-
ment method employing solid-state ­laser sources. The sensor remains unaffected by contaminants and corrosives and does
not require regular maintenance. The absence of extractive conditioning systems f­ urther improves ­availability of the
measurements and eliminates errors related to s­ ample handling. The monitor is mounted directly onto flanges, which include
purge gas c­ onnections and a tilting mechanism for easy alignment. Continuous purge flow ­prevents dust and other contam-
ination from settling on the optical windows. Once power and data lines are connected, measurements are performed in
real-time.

Features Applications Customer benefits

• Response time down to 1 second LaserGasTM II SP is designed for reliable and • In-situ monitoring
• No gas sampling: In-situ measurement fast measurement of all kinds of gases in • Highly reliable real time analyzer
any environment, most typically:
• No interference from background gases • Limited need for maintenance
• No moving parts, no consumables • Low maintenance cost
• Chemical industry
• ATEX and CSA certified • Reduce emission to the environment
• Petrochemical industry
• Can measure through very thin nozzles • Easy to install and operate
• Metal industry
<10 mm diameter • Reduce daily operation costs
• Power plants
• Optimised for very short distance meas- • Optimize process
urements across pipes and along short • Waste incinerators
• Well proven measurement technique
cells • Cement industry
• Requires low purge flow
• Compact design • Automotive industry
• No zero drift • Scrubber technology
• Stable calibration • Glass industry
• PVC production
• Pulp and paper
• and more

NEO Monitors as • A subsidiary of Norsk Elektro Optikk • Prost Stabels vei 22, • N-2019 Skedsmokorset, Norway
Phone +47 67 97 47 00 • www.neomonitors.com
LaserGas™ II Compact
Technical Data

Spesifications Installation and Operation Explosion protection (optional)


Optical path length: Typically 0.1-1m Flange dimension alignment: DN50/PN10 or ATEX zone 2: II 3 G Ex nA nC op is IIC
Response time: 1 – 2 sec ANSI 2’’/150lbs (other T4 Gb
Accuracy: Application depended dimensions on request) II 3 D Ex tD A22 T100°C
Repeatability: 1% of range (gas and Alignment tolerances: Flanges parallel CSA: Class I, Div. 2, Groups A,
application spesific) within 1.5º B, C and D; Temp. Code
Purge flow: Dry and oil-free T4; non-incendive
Environmental conditions
pressurised air or gas
Operating temperature: -20 ºC to +55 ºC
or by fan
Storage temperature: -20 ºC to +55 ºC Dimension and weight
10-50 l/min per flange
Protection classification: IP66 Transmitter unit: 195 (plus 65 for purge
(application dependent)
Inputs / Outputs unit) x270x170 mm,
2-4 l/min per flange 4.8 kg
Analogue output (3): 4 – 20 mA current loop ­
when set up with thin
(concentration,
nozzles (optinal)
transmission) Transmitter unit: 195 (plus 65 for purge
Digital output: TCP/IP, MODBUS, Maintenance (EX ver.) unit) x 270x310 mm,
Optional fibre optic Visual inspection: Recommended every 6.5 kg
Relay output (3): High gas-, Mainte- 6 – 12 months (no
nance, Warning - and consumables needed) Receiver unit: 208 (plus 65 for purge
Fault relays (normally Calibration: Recommended every unit) x 125 x 125 mm,
closed-circuit relays) 12 months 2.6 kg
Input: 4 – 20 mA process ­ Validation: With optional
temperature and ­ flow through cell
Power supply unit: 180 x 85 x 70 mm,
pressure reading
Safety 1.6 kg
Ratings
Laser class: Class 1 according to
Input power supply unit: 100 – 240 VAC,
IEC 60825-1
50/60 Hz, 0.36 – 0.26 A
CE: Certified, conformant
Output power supply unit: 24 VDC,
with LVD 73/23/EEC,
900 – 1000 mA
including 93/68/EEC
Input transmitter unit: 18 – 36 VDC, max. 20 W
EMC: Conformant with
4 – 20 mA output: 500 Ohm max. isolated
directive 2004/108/EC
Relay output: 1 A at 30 V DC/AC

NOTE: Detection limits are specified as the 95% confidence interval


Gas Detection limit (ppm) Max temp (ºC) Max pressure (bar abs)
for 1m optical path and gas temperature / pressure = 25 ºC / 1 bar abs.
NH3 0,15 600 2 Measured in N2.
HCI 0,05 600 2
Other gases might be available on request.
HF 0,015 400 2
H2S 3 300 2 Dual Gas: NH3+H2O, HCI+H2O, CO+CO2, CO+H2O, CO+CH4, O2+temp,
CO+temp and others.
O2 100 600 2
% H2O 50 600 2 Higher pressure may be available on request for certain gases.

ppm H2O 0,1 400 2 Please contact us for details.


% CO 30 600 2
% CO2 30 600 2
ppm CO 0,3 600 2
ppm CO2 0,2 300 2 Your local distributor:
NO 10 300 2
N2O 1 200 2
CH4 0,2 300 2

NEO Monitors as • A subsidiary of Norsk Elektro Optikk


Prost Stabels vei 22, • N-2019 Skedsmokorset, Norway • Phone +47 67 97 47 00 • www.neomonitors.com