0% found this document useful (0 votes)
67 views3 pages

Spesifikasi Medgyn SD5

The document provides specifications for an ultrasonic table-top Doppler device made by Medgyn in the US. It lists technical details such as environmental requirements, physical dimensions, power supply information, safety standards, and performance specs for fetal heart rate monitoring, recording/playback, and ultrasound output. Battery details are also provided for the main unit and probe.

Uploaded by

RB RSUDMP
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views3 pages

Spesifikasi Medgyn SD5

The document provides specifications for an ultrasonic table-top Doppler device made by Medgyn in the US. It lists technical details such as environmental requirements, physical dimensions, power supply information, safety standards, and performance specs for fetal heart rate monitoring, recording/playback, and ultrasound output. Battery details are also provided for the main unit and probe.

Uploaded by

RB RSUDMP
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

SPESIFIKASI ALAT

NO DESCRIPTION

1 ULTRASONIC TABLE - TOP DOPPLER


MERK : MEDGYN - USA
MODEL : SD 5

Specifications :

1. Environmental

Working
Temperature: : +5 ºC ~+ 40 ºC ( +41 ºF ~ +104 ºF)
Relative Humidity: : 25% ~ 80% (non-condensing)
Atmospheric Pressure: : 860hPa ~ 1060hPa

Transport and Storage


Temperature: : -20 ºC ~ +55 ºC (-4ºF ~ +131 ºF)
Relative Humidity: : 25% ~ 93% (non-condensing)
Atmospheric Pressure: : 700hPa ~ 1060hPa

2. Physical

Dimensions and nett weight


Dimensions: : Main Unit: 265mm x 155mm x 180 mm
Probes: 140mm x 40mm x 32 mm
nett weight: : Main Unit: 1.7 kg (with battery and probe)
Wired Probe: 85 g

Power Supply
Main unit : Operating Voltage : 100V-240V~
Operating Frequency : 50Hz/60Hz
Input Power : 35VA
Battery : 7.2V/2000mAh (Ni-MH Battery)
Probe Battery : 3.7V/700mAh (Lithium Battery)

Standards Compliance : IEC 60601-1:1988+A1+A2, EN 60601-1:1990+A1+A2,


IEC/EN 60601-1-2:2001+A1, IEC/EN 61266, IEC/EN 60601-2-37

Anti-electric Shock Type : Class I equipment with internal power supply


Anti-electric Shock Degree : Type B applied parts

Degree of Protection against Main Unit: Not-protected


Harmful Ingress of Water Probe: IPX4

Degree of Safety in Presence


of Flammable Gases : Equipment not suitable for use in presence
of flammable gases

Disinfection/Sterilizing Method : Refer to this user manual for details

EMC : Group I Class A

Earth Leakage Current (Limit):


N.C. : 500μA

Page 1
NO DESCRIPTION
S.F.C. : 1000μA

Enclosure Leakage Current (Limit):


N.C. : 100μA
S.F.C. : 500μA

Patient Leakage Current (Limit):


N.C. S.F.C.
N.C. : d.c. 10μA a.c. 10μA
S.F.C. : d.c. 50μA a.c. 50μA

Patient Auxiliary Current (Limit):


N.C. : d.c. 10μA a.c. 10μA
S.F.C. : d.c. 50μA a.c. 50μA

Display:
Effective display area: : 62.0 mm (W)x 44.0 mm(H)
Number of characters: : 128*64 Dots
Dot size: : 0.39 mm(W) x 0.55 mm(H)
Dot pitch: : 0.44 mm(W) x 0.60 mm(H)

3. Performance

FHR Performance:
FHR Measurement Range: : 50bpm ~ 210bpm
Resolution: : 1 bpm
Accuracy: : ± 3 bpm

Recording and Playing:


Audio Sampling Frequency: : 4KHz
Recording Length: : 240s

White Back Light:


Two Brightness Adjustable: : OFF, ON

Audio Output Power: : 2W

Auto Shut off: : 1-minute/3-minute no signal and no operation

Ultrasound:
Nominal Frequency: : 2MHz wired Probes : 2MHz
3MHz wired Probes : 3MHz
4MHz wired Probes : 4MHz
5MHz wired Probes : 5MHz
8MHz wired Probes : 8MHz

Working Frequency: : 2MHz wired Probes: (2.0 ± 10%)MHz


3MHz wired Probes: (3.0 ± 10%)MHz
4MHz wired Probes: (4.0 ± 10%)MHz
5MHz wired Probes: (5.0 ± 10%)MHz
8MHz wired Probes: (8.0 ± 10%)MHz

2MHz wired probe: : Iob < 10 mW/cm2


3MHz wired probe: : Iob < 10 mW/cm2
4MHz wired probe: : Iob = 15.8688 mW/cm2
5MHz wired probe: : Iob = 23.15 mW/cm2
8MHz wired probe: : Iob = 21.68 mW/cm2

Page 2
NO DESCRIPTION
p- < 1MPa
Ispta < 100mW/cm2

Working Mode: : Continuous wave Doppler

Effective Radiating Area of Probe:


2MHz /3MHz wired probes : (245±15%)mm2
4MHz /5MHz wired probes : (32±15%)mm2
8MHz wired probes : (14±15%)mm2

4. Battery
For main unit
Type: Ni-MH Battery
Nominal Capacity: 2000mAh
Nominal Voltage: 7.2V
Charge Current (Standard): 757mA
Charge Voltage (Standard): 9V
Necessary Charge Time Approx. 3h
Expected Battery Life: Approx. 10h
Charge Mode: Constant current/Constant voltage
Circle Life: ≥300 times (after 300 circles, only 90% of the capacity
can be restored.)
Storage Temperature: -20°C ~ +60°C (-4 ºF ~ +140 °F) (1 month) or
-20°C ~ +40°C (-4 ºF ~ +104 °F) (3 months)

All specifications are subject to modifications and improvements without prior notice