Advanced Safety

Integrity – The best


solution for gas
detection in critical
safety applications.

Detection at every point.


Advanced Safety Integrity – The best solution for gas
detection in critical safety applications.

SensAlert ASI provides enhanced protection and


dependability for critical safety applications where
personnel, processes, and facilities are at risk. The third-
party certified SIL-2 SensAlert ASI offers dependability
and versatility while remaining the easiest to install,
commission, operate, and maintain.

Critical Protection with Global Approval


SensAlert ASI is third-party certified to IEC61508 Level 2 (SIL-2) for both hardware
and software with certification to global hazardous area and performance
standards. The Test-on-Demand feature with on-board gas generator provides
remote functionality checks with generated gas while Predictive Sensor End-of-Life
Indication provides advanced warning of impending sensor failure.

Unmatched Application Versatility


SensAlert ASI is a universal instrument platform for toxic & combustible gas
detection and oxygen monitoring. Intrinsically safe or explosion proof installation
configurations with options for remote sensors and gassing, duct mount, and
sample-draw maximize application versatility. Intrinsically safe or explosion
proof installation configurations for remote sensors and gassing, duct mount,
and sample-draw maximize application versatility. The sensor head accepts all
Plus Series sensor technologies – infrared, catalytic bead, and electro-chemical.
Assignable and configurable relays together with communication options provide
broad flexibility. The SensAlert ASI I.S. sensor head can be remote mounted up
to 100 feet (30m) from the transmitter providing a useful option to position the
transmitter in a personnel-accessible location while positioning the sensor closer
to potential hazards.

Easy to Install, Commission, Operate, and Maintain


SensAlert ASI is engineered to overcome the challenges users face with traditional
gas detectors. The universal instrument platform for all gas and sensor types
provides common installation for each point with vertical or horizontal installation
options and removable plug-type terminal blocks to simplify wiring and
commissioning. Transportable calibration enables sensor calibration and alarm
set-up in a safe location, then installing sensors into the intrinsically safe sensor
head without declassifying the area or removing power from the instrument. Plug-
n-play capability automatically uploads operating parameters and diagnostics from
the sensors upon sensor installation. A Sensor Calibration & Exchange Program
schedules delivery of factory calibrated sensors to the user’s plant or facility for a
savings on maintenance and supply costs.

Detection at every point.


Non-intrusive User Interface
SensAlert ASI transmitters have a non-intrusive menu driven interface designed for
effortless set-up and maintenance. The menu is free from complex icons and symbols
and does not require use of remotes or connectors to interface with the transmitter.
Below are actual menus and system displays.

Main Display Main Menu

Duct Mount

Sensor Data Review System Configuration Menu

Remote Mount

Predictive Sensor Life Test-on-Demand Data Review


SensAlert ASI provides true installation
and application flexibility for local or
remote mount sensors to place the
sensor closer to potential gas sources.

Live Test-on-Demand Sensor Verification Test-on-Demand Adjustment Menu


Technical Specifications
Advanced Safety Integrity – The best solution for gas Sensors
Gas Sensors:.....................Electrochemical, Infrared, Catalytic Bead
detection in critical safety applications. Test-On-Demand Modules:..................................Type C and Type S

Electrical
Voltage/Power:
2-Wire 24 VDC (18-30 VDC):............................................ 20 mA
3-Wire 24 VDC (12-30 VDC): ........................................... 90 mA
Enclosure Options Certified With opt. Relay Card and combustible sensors:............ 300 mA
for most Environments Output and load resistance with 24 VDC
at transmitter terminals:
3 wire 4-20 mA:............................................... 600 Ω maximum
2-wire 4-20 mA:.............................................. 350 Ω maximum
Relay:.....................3-Wire Only - One SPDT Configurable Relay
Optional Card:.....................Three (3) SPDT Configurable Relays
Large Backlit Alphanumeric Contact Ratings:....................................... 5 Amps at 115 VAC or
Display 30 VDC Resistive
(Backlit on 3-wire only) Communication Link................... 4-20mA current, non-isolated
2 or 4-wire options, RS-485 (Modbus), HART

Controls
Magnetic Keypad:..................................... ACK, << (Go Back), ▲, ▼
Intrinsically Safe Sensor Security:...........................Password Protected Configuration Menu
Head
Displays
LEDs:................................. Four (4) Red, corresponding to magnetic
keypad, and Alarm Relays when equipped.
Graphic LCD:............................ 128 by 64 pixel screen (backlight on
. 3-wire transmitters); displays Concentration
Test-On-Demand (ToD)

and Measuring Units, Gas Name or Type,
Gas Generator Sensor Span, Date and Time, Tag Number
(Optional) and System messages or Warnings

Environmental
Temperature (Transmitter):................ -40°F to 158°F /-40°C to 70°C
Humidity (Transmitter).......................... 0-90% RH, non-condensing
Temperature (Sensor):................................. See Sensor Data Sheets
Plus Intelligent Sensor Humidity (Sensor):...................................... See Sensor Data Sheets
Moisture Resistance...................IP54; IP56 with optional rainshield

Enclosure Options
Standard:..................................... Blue, Copper-free Cast Aluminum
Dimensions:....................................... 6.7” W x 12.2” H x 6.5” D
O-ring Seal 170 mm W x 308 mm H x 165 mm D
Weight Range:................................................6-8 lbs /2.7-3.6 kg
Long-dome.................................. Gray, Copper-free Cast Aluminum
Physical: ............................................ 6.3” W x 11.7” H x 7.1” D
160 mm W x 297 mm H x 180 mm D
Weight Range:............................................7-8.7 lbs / 3.2-4.0 kg

Sensor Retainer Approval Ratings


Explosion Proof ...................................... NEC and CEC Class I Div 1,
Grps A, B, C, D;
Class II Grps E, F, G; Class III T4
Flame proof........................................ATEX EEx d[ia] IIC T4 II 2 [1] G
Non-Incendive NEC and CEC Class I Div 2,
(Enclosed Break) Groups A, B, C, D;
Sensor Shield . Class II Grps E, F, G; Class III T4
ATEX EEx nC [ia] IIC T4 II 3 [1] G
Intrinsic Safety................ NEC and CEC Class I Div 1, Grps A, B, C, D;
Class II Grps E, F, G; Class III T4
ATEX EEx ia IIC T4 II 1 G
CE Mark........................................................ATEX Directive 94/9/EC
IECEx................ Zone 0: Display Ex d [ia] IIC T4 / Sensor Ex ia IIC T4;
Baffled Rainshield Zone 1: Ex d [ai] IIC T4; Zone 2: EXnC [ia] IIC T4
(Optional) UL / IEC................................ IEC 60079-0:2006, IEC 60079-11:1999,
IEC 60079-15:2007
SIL-2 Certified.................... IEC 61508 SIL-2 Parts 1,2, & 3 Hardware
& Software. Fit for use in SIL-2 applications.

Calibration Plug

© 2012 Sensidyne, LP — SAasiDS-Rev. B 06.29.12

16333 Bay Vista Drive • Clearwater, Florida 33760 • U.S.A


Tel: 800-451-9444 / +1 727-530-3602 • Fax: +1 727-539-0550
[email protected] • www.SensidyneGasDetection.com