Advanced Climate Control Sensor

The EE210 sensor measures relative humidity and temperature for demanding climate control applications. It calculates additional humidity parameters and interfaces with BACnet or Modbus networks. The sensor offers excellent performance in polluted environments thanks to encapsulated electronics and a proprietary coating. It can be wall or duct mounted, and includes an IP65 rated enclosure for outdoor installation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views4 pages

Advanced Climate Control Sensor

The EE210 sensor measures relative humidity and temperature for demanding climate control applications. It calculates additional humidity parameters and interfaces with BACnet or Modbus networks. The sensor offers excellent performance in polluted environments thanks to encapsulated electronics and a proprietary coating. It can be wall or duct mounted, and includes an IP65 rated enclosure for outdoor installation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

EE210 Humidity and Temperature Sensor

for Demanding Climate Control


The EE210 sensor by E+E Elektronik meets the highest requirements in
demanding climate control applications. Besides the accurate measurement
of relative humidity (RH) and temperature (T), EE210 calculates various RH
related parameters such as dew point, temperature, absolute humidity and
mixing ratio. All measured and calculated values are available on the BACnet
MS/TP or Modbus RTU interface, two of them are available on the analogue
voltage or current outputs, while up to three values can be shown simultan-
eously on the optional display.
Excellent performance of EE210 in polluted or aggressive environment is
ensured by the encapsulated measurement electronics inside the sensing
probe and the long-term stable HCT01 sensor with E+E proprietary coating.
EE210 is available as wall or duct mounted version as well as with remote
probe.The IP65 / NEMA 4 enclosure minimizes installation costs and provides
outstanding protection against contamination and condensation.
With an optional USB configuration adapter, the user can set the RS485 interface parameters, the output scaling and perform one
or two point adjustment for RH and T.

Applications
• agriculture • green houses • indoor pools
• stables, incubators, hatchers • storage rooms, cooling chambers • demanding climate control

Features
Appropriate for US mounting
Display
requirements
»» Selectable display layout
»» Knockout for ½” conduit fitting
»» Measurands freely
selectable
»» Backlight optional
External mounting holes
»» Mounting with closed cover
»» Electronics protected against
construction site pollution Smooth cover surface
»» Easy and fast mounting »» No accumulation of dust
in protruding edges

Electronics on the underside of the PCB


»» Optimum protection against mechanical IP65 / NEMA 4
damage during installation Enclosure

Bayonet Screws
Watertight
»» Open/closed with a ¼ rotation
cable outlet

Cast Electronics
»» Mechanical protection
»» Condensation-resistant

E+E Humidity sensor HCT01


»» Long-term stability
»» Protected solder pads
»» Tested according to automotive Inspection certificate
standard AEC-Q200 according DIN EN 10204 – 3.1 BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse,
approve or test products for compliance with ASHRAE standards. Compliance of
listed products to the requirements of ASHRAE Standard 135 is the responsibility
of BACnet International (BI). BTL is a registered trademark of BI.

36 v2.6 / Modification rights reserved EE210


Protective Sensor Coating
The E+E proprietary sensor coating is a hygroscopic layer applied to the
active surface of the HCT01 sensing element. The coating extends substan-
tially the life-time and the measurement performance of the E+E sensor in
corrosive environment (salts, off-shore applications). Additionally, it improves
the sensor’s long term stability in dusty, dirty or oily applications by preventing
stray impedances caused by deposits on the active sensor surface.

Technical Data
Measured Values
Relative Humidity (RH)
Working range 0...100 % RH
RH accuracy1) (incl. hysteresis, non-linearity and repeatability)
Wall & duct version:
-15...40 °C (5...104 °F) ≤90 % RH ±(1.3 + 0.003*measured value) % RH
-15...40 °C (5...104 °F) >90 % RH ± 2.3 % RH
-40...60 °C (-40...140 °F) ±(1.5 + 0.015*measured value) % RH
Remote probe version
at 20 °C (68 °F) ±2.5 % RH
Temperature (T)
Sensor Pt1000 (tolerance class B, DIN EN 60751) integrated in HCT01
T-accuracy wall & duct remote probe
± ∆ °C ± ∆ °C

°C °C

Outputs
Analogue output 0-5 V / 0-10 V -1 mA < IL < 1 mA
4-20 mA (2-wire) RL ≤ 500 Ohm
0-20 mA (3-wire) RL ≤ 500 Ohm
Digital output RS485 (BACnet MS/TP or Modbus RTU), max. 32 EE210 in one bus
General
Power supply (Class III)
for 4-20 mA, 2-wire 10 V + RL x 20 mA < V+ < 30 V DC

for 0-20 mA, 3-wire 15-35 V DC2) or 24V AC ±20 %


for 0-5 V / 0-10 V / RS485
Current consumption at 24 V
Voltage output DC supply max. 12 mA; with display max. 23 mA
AC supply max. 34 mArms; with display max. 49 mArms
Current output
2-wire DC supply max. 40 mA; with display max. 40 mA
3-wire DC supply typ. 33 mA; with display max. 44 mA
AC supply typ. 65 mArms; with display max. 84 mArms
Digital interface DC supply typ. 5 mA; with display max. 20 mA
AC supply typ. 15 mArms; with display max. 35 mArms
1) Traceable to intern. standards, administrated by NIST, PTB, BEV,... The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2
(2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).
2) USA & Canada: class 2 supply required, max. supply voltage 30 V

EE210 v2.6 / Modification rights reserved 37


Display 1, 2 or 3 lines, user configurable, optional with backlight
Electrical connection Screw terminals, max. 1.5 mm2
Housing material Polycarbonate, UL94V-0 (with Display UL94HB) approved
Protection class IP65 / NEMA 4
Cable gland M16 x 1.5
Probe cable (type PC) PVC, Ø 4.3 mm, 4 x 0.25 mm2, Length: 1.5 or 3 m (4.9 or 9.8 ft)
Electromagnetic compatibility EN61326-1 EN61326-2-3
Industrial Environment
Temperature ranges Working: -40...60 °C (-40...140 °F) (-40...80 °C / -40... 176 °F for probe EE210P)
without display Storage: -40...60 °C (-40...140 °F)
Temperature ranges Working: -20...50 °C (-4...122 °F) (-40...80 °C / -40... 176 °F for probe EE210P)
with display Storage: -20...60 °C (-4...140 °F)

Dimensions (mm/inch)

Type PA Type PB
±0.3 mm
90 ±0 .11 “ ±0.3 mm
3.54 90 ±0 .11 “
FOR CONDUIT 3.54
46
m INSTALLATION
1.8 m Ø > 13 mm
1“
Ø > 0.51“
Len
gth
acc
ord
ing m
to o
rde 101 m
3.98“
80.6 mm

ring
guid
3.17“

e
5 mm
0.2“

GASKET

L = filter cap mm (inch)


Membrane 34 (1.4“)
~55 mm
~2.16“

Stainless steel 33 (1.3“)


CABLE GLAND M16x1.5 19 mm
0.75“

Type PC Ø 12 mm
Ø 0.47“ EE210P ±0.3 mm
60 ±0 .11 “
2.36

Ø > 16 mm
Ø > 0.63“
6 mm
m 0.24“
m
6 “
10 .17
4

Mounting flange
in the scope of supply for
Type PA and PC

Accessories
USB configuration adapter HA011066
Product configuration software EE-PCS (free download: www.epluse.com/EE210)
Power supply adapter V03 (see data sheet Accessories)
Protection cap for 12 mm probe HA010783

38 v2.6 / Modification rights reserved EE210


Ordering Guide
MODEL OUTPUT TYPE PROBE LENGTH2) DISPLAY3) FILTER (Type A and B)
humidity + (HT) 0-5 V (2x) wall mount (PA) 50 mm (1.97“) (B) without backlight4) (D) membrane (B)
temperature 0-10 V (3x) duct mount (PB) 200 mm (7.87“) (F) with backlight5) (E) stainless steel sintered (D)
0-20 mA (3-wire) (5x) remote probe (PC)1) Type A and C (x) none (x) for type C (x)
4-20 mA (2-wire) (6x)
RS485 (x3)

EE210-

Analogue outputs (2x, 3x, 5x, 6x) setup


OUTPUT 1 SCALING 17) OUTPUT 2 SCALING 27) UNIT
relative humidity6) (Uw) -40...60 (002) relative humidity6) (Uw) -40...60 (002) metric (M)
temperature (Tx) -10...50 (003) temperature (Tx) -10...50 (003) non-metric (N)
dew point temperature (TD) 0...50 (004) dew point temperature (TD) 0...50 (004)
frost point temperature (TF) 0...100 (005) frost point temperature (TF) 0...100 (005)
water vapour partial pressure6) (Ex) 32...122 (076) water vapour partial pressure6) (Ex) 32...122 (076)
mixing ratio6) (Rx) -40...140 (083) mixing ratio6) (Rx) -40...140 (083)
absolute humidity6) (DV) absolute humidity6) (DV)
specific enthalpy6) (Hx) specific enthalpy6) (Hx)
wet bulb temperature (TW) wet bulb temperature (TW)

Digital output (x3) setup8)


PROTOCOL BAUDRATE PARITY STOPBITS UNIT
Modbus RTU8) (1) 9600 (A) odd (O) 1 stopbit (1) metric (M)
BACnet MS/TP9) (3) 19200 (B) even (E) 2 stopbit (2) non-metric (N)
38400 (C) no parity (N)
5760010) (D)
7680010) (E)
11520010) (F)

Remote probe for EE210 Type PC:


MODEL CABLE LENGTH FILTER
humidity + temperature (HT) 1.5 m (4.9 ft) (C) membrane (B)
3 m (9.8 ft) (E) stainless steel sintered (D)

EE210P-
1) The EE210P probe has to be ordered as seperate position 7) For Tx, TD, TF and TW; see data sheet „Scaling of the outputs“ at www.epluse.com
2) Selectable probe lenght only for duct mount version available; see dimensions 8) Modbus Map and setup instructions:
3) Factory setup: See User Guide and Modbus Application Note at www.epluse.com/EE210
For analogue output versions the display shows the measurands selected for output 1 and output 2. 9) Product Implementation conformance Statement (PICS) availbale at www.epluse.com/EE210
For digital output versions the display shows RH and T 10) Only for BACnet
4) Not with output 5x
5) Not with output 6x
6) Factory Scaling
relative humidity 0...100 % RH
water vapour partial pressure 0...200 mbar 0...3 psi
mixing ratio 0...400 g/kg 0...2800 gr/lb
absolute humidity 0...150 g/m³ 0...60 gr/ft³
specific enthalpy -50...400 kJ/kg -10...190 BTU/lb

Order Examples
Type PA and PB Type PC
Position 1:
EE210-HT3xPAxEB-UwTx005M EE210-HT6xPCxxx-UwTx005M
Model: Humidity+Temperature Model: Humidity+Temperature Basic Device
Output: 0-10 V Output: 4-20 mA
Type: wall mount Type: remote probe (Pos. 2)
Display: with backlight Display: none
Filter: membrane
Output scaling 1: relative humidity
Output scaling 1: relative humidity Scaling 1: 0...100 % RH
Scaling 1: 0...100 % RH Output scaling 2: temperature
Output scaling 2: temperature Scaling 2: 0...100 °C
Scaling 2: 0...100 °C Unit: metric
Unit: metric

Position 2:
EE210P-HTCB
Model: Humidity+Temperature Probe
Cable length: 1.5 m
Filter: membrane
EE210 v2.6 / Modification rights reserved 39