0% found this document useful (0 votes)
188 views27 pages

F11 Installation Guide V1.0

The document provides installation instructions for the F11 fingerprint access control device. It discusses: 1) Important safety notices for installing the device, such as turning off the power before wiring and using shielded cable. 2) An overview of the device's operation panel, including the power button, fingerprint sensor, and LED indicator. 3) Details on connecting the device to external equipment like an access controller, alarm system, door lock, and power supply. Proper cabling and wiring methods are emphasized.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
188 views27 pages

F11 Installation Guide V1.0

The document provides installation instructions for the F11 fingerprint access control device. It discusses: 1) Important safety notices for installing the device, such as turning off the power before wiring and using shielded cable. 2) An overview of the device's operation panel, including the power button, fingerprint sensor, and LED indicator. 3) Details on connecting the device to external equipment like an access controller, alarm system, door lock, and power supply. Proper cabling and wiring methods are emphasized.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 27

F11 

Installation Guide 

Version: 1.0 
Date: Jul. 2010
Table of Contents 

Table of Contents 
1. Before Installing................................................................................................1 
1.1 Notice About Installing ...........................................................................1 
1.2 Operation Panel: .....................................................................................3 
2. System Configuration ........................................................................................5 
3. Installation ........................................................................................................5 
3.1 Device Installation ..................................................................................5 
3.2 Connect with External Equipment ...........................................................6 
3.2.1 Connect to the Access Controller .................................................7 
3.2.2 Connect to Alarm ........................................................................9 
3.2.3 Door Lock Connection ..............................................................10 
3.2.4 Communication Mode ...............................................................13 
3.2.5 Complementary Communications ..............................................15 
3.2.7 Power Connections....................................................................17 
3.3 Fixed the Device...................................................................................17 
4. Other Functions...............................................................................................19 
4.1 Reset Button .........................................................................................19 
4.2 Tamper Switch......................................................................................19 
4.3 Built­in EM Card Reader (Optional)......................................................20 
4.4 Built­in MIFARE Card Reader (Optional)..............................................21 
5. Trouble Shooting .............................................................................................22


1. Before Installing 

1. Before Installing 

1.1 Notice About Installing 

This  device  is  a  mass­produced  product.  It  strictly  tested  comply 


with the standard of China, U.S.A, and EU. This file contains important 
information. It is better for you to read it carefully prior to use. If you 
ignore  it,  the  incorrect  installation  may  cause  the  unit  damage. 
Although  we  could  do our best to offer  you service, the neglect  to the 
guide could cause unwanted cost for you. 

1.  Before  installation,  please  make  sure  the  power  is  cut  off, 
because  it  is  very  dangerous  if  the  power  is  on.  The  short  circuit  of 
power cable may cause the core parts damage. 

2.  All  exposed  part  of  connection  wire  end  cannot  be  exceeded 
5mm  to  prevent  the  bared  wire  accidental  connection  which  leads  to 
device  break  down.  And  also  suggest  using  different  color  cable  to 
connect. 

3.  In  the  place  where  the  static  is  strong  or  in  winter,  please 
connect the grounding firstly, in order to prevent the instant mass static 
damage the device. 

4.  Connect  power  supply  with  device  in  the  last  for  the  wiring 
connection. If you find any unusual thing occur, please firstly cut off the 
power, then go to examine. Keep in mind: wiring operation under power 
on  will  lead  to  device  sudden  damage;  we  are  not  liable  for  damages 
and troubles due to such operation.


F11 Installation Guide V1.0 

5. The height to mount device is about 1.4­1.5 meter. 

6.  After  installation,  please  take  off  protection  film  on  the  fingerprint 
sensor to get best recognize result. 

7.  After installation  finish, when  go to test the  exit button,  please 


keep a personal in the  outside, because sometimes the accidental issue 
can bring on you that you are not able to go outside. 

8.  It  is  good  to  use  more  than  12V/1.5A  independent  DC  power 
supply  for  this  device.  It  can  reduce  the  electric  interference  between 
the  device  with  controller  or  electric  lock,  current  ripple  wave  is  less 
than 150mV. 

9. In connecting of the Fingerprint reader, 8­shielding cable (RVVP 
8X0.3MM2) is recommended to reduce the interference in the course of 
transmission,  please  read  and  always  follow  "F11  Installation  Guide" 
closely. Because the wrong wiring will cause the core block and sensor 
to burn out, lead to device breaking down, at this cause we are not liable 
for any damages and troubles. 

10.  +12VDC  power  supply  cable  by  two­core  power  cord  (RVV 
2X2.5MM2), If the distance between  power adapters and device is too 
long, please do not use the other type wire for replacement. When you 
select the power wire, you should pay attenuation to the voltage decay 
of long distance transfer. 

11. Please use specialized RS485 cable, 
the internationally popular 
RVVP  (shielded  twisted  pair)  is  recommended,  Model  RVVP 
2x0.5­1.5mm2  (two  core  shielded  twisted  pair)  and  the  active 
RS232/RS485 converter to connect with the  network, the bus structure 
apply to connect with each device. When a long cable is used to transfer


1. Before Installing 

signal, it is need to connect a matching resistance to each terminal, and 
its value is 120Ώ. 

12. Signal cable (such as RS485 cable) and high­power electricity 
cable (such as AC electric, locking cable) can not place in parallel. If it 
is necessary, please put them about 50cm away. 
More details please see to the F11 User Manual, the appendix, the 
other instructions and so on. 

1.2 Operation Panel 

Power Button 

LED Indicator 

Fingerprint Sensor 

Sensor Area 

1.  Power  Button:  Press  and  hold  the  power  button  for  three 
seconds  to  turn  the  power  off,  press  and  hold  the  power  button  one 
second to turn it on. 

2.  Fingerprint  Sensor:Used  to  enroll  or  match  fingerprint  and 


delete user.


F11 Installation Guide V1.0 

3.  LED  Indicator:  The  LED  indicator  is  used  to  display  device 
operation, enrollment, deletion or verification state. 
4.  Card  Sensor  Area:  Used  to  sense  the  administrator  card  for 
management, or the ordinary card for enrollment, matching and deletion.


2. Installation 

2. Installation 

2.1 Standard Connection 

There  are  three  modes  that  the  PC  software  communicate  and 
exchange information with the device: RS232, RS485, TCP/IP. RS485 and 
TCP/IP modes support remote control. 

The standard connection diagram shown below: 

2.2 Device Installation 

This  product  is  designed  for  indoor  installation,  if  it  has  to  be 
installed outdoor, please place the equipment in proper surroundings, you 
must  beware  of  not  exposing  it  to  water  or  harsh  condition  ,  we 
recommend to embed the cable into the wall, if it isn’t capable to do, you 
must obtain the user’s permission before installing.


F11 Installation Guide V1.0 

2.3 Connect with External Equipment 

To  avoid  the  possible  damage  to  the  device,  before  connecting  or 
disconnecting external equipment, you should make sure to disconnect the 
power  cable  first.  Please  follow  the  installation  guide  to  connect  the 
external equipment. 

1. Access Controller. 
2. Alarm. 
3. Various network.. 
4. Auxiliary communication interface.


2. Installation 

5. Power supply. 

Wiring terminal for external equipment shown as below: 

2.3.1 Connect with Access Controller 

As a fingerprint reader, F11 can not work alone until it connect with 
the  access  controller.  It  is  only  a  fingerprint  identification  device  in  the 
system, and provide the controller with a standard or self­define Wiegand 
signal. Such as others card reader we adopt the standard signal (D0, D1, 
GND) connection mode (See Standard Connection Diagram). 

?Notice: Whether the power of F11 supply by the access controller or 
not,  the  two  equipment’s  GND  must  be  in  common  connection.  Do  not 
replace  Weigand  signal  GND  with  power  GND.  To  ensure  the  wiegand 
signal transfer steady, please separately plot wiring.


F11 Installation Guide V1.0 

T HD  T IW  T SD 

WD0  SS

T DW 

WD1  SS 

Specifications: 

TDW pulse: 400 um 
TIW cycle: 2000 ms 
Output drive capability: 200 mA 

Definition terminal connection (7 PIN Cable) : 

Terminals  Function 

1  ALM  Alarm Signal 


2  GLED  Indicator Control 
3  RLED  Indicator Control 
4  BEEP  Beep Control 
5  WD1  Wiegand Output 
6  WD0  Wiegand Input 
7  GND  Power Output


2. Installation 

2.3.2 Connect to Alarm 

F11 can connect a alarm signal (Alarm) to system, which mainly use 
to  remind  that  the  F11  has  been  dismantled.  No  matter  what  condition, 
when  it  is  removed,  F11  will  trigger  alarm  output  in  the  power  on  state, 
otherwise,  the  wire  doesn’t  send  any  signal.  F11  will  link  GND  through 
the  wire  if  the  system  be  triggered,  follow  this  principle  we  can  achieve 
the  remind  function  of  dismantled  alarm.  Connect  the  negative  of  alarm 
power to alarm output, the positive of alarm power connect to the positive 
of  F11  power  (See  the  figure  below),  F11  alarm  output  only  support 
12VDC alarm. 

?Notice: There is a tamper switch in the bottom of F11. For details, see 
3.2 Tamper Switch. 

Alarm connection diagram shown as below:


F11 Installation Guide V1.0 

?Notice: The power output of the alarm is no more than DC12V. 
2.3.3 Door Lock Connection 

The way of installing door lock depends on the type of lock and local 
condition.  Internal  resistor  which  comes  from  long  distance  transfer 
should  be  taken  into  consideration  when  selecting  the  cable  of  electric 
power.  The  door  lock  should  be  installed  reliable  and  stable.  Ensure  the 
wiring is correct. For the strike lock and electromagnetic lock, you should 
pay  attention  to  positive  and  negative  terminal  connection.  The  unused

10 
2. Installation 

bare end of wire should be cut off and use insulating tape to wrap it. The 
delay time of strike lock is adjustable according to different conditions. 

Select electric lock:It is better to use electric drop bolt for the two 
direction opening glass door (Both open to inside or outside direction). For 
the single opening wood door in company internal, we recommend to use 
magnetic lock, the magnetic lock also be called as electric magnetic lock. 
The  magnetic  lock  is  more  reliable  than  the  electric  drop  bolt,  but  the 
electric drop bolt is much safer than the magnetic lock. In the small living 
community, it is better to  use  electric  drop bolt and  magnetic  force  lock. 
The electric control lock gives out higher noise. The electric control lock 
is  commonly  used  to  building  communication.  Now  there  is  a  soundless 
electric control lock which is able to be applied. Please pay attention, the 
lock is made of iron and easy rust, so you must beware of not exposing it 
to water or harsh condition, there are some  other electric locks available, 
we don’t recommend you to use them. 

Connect with electric lock:  The Normal Open lock is open when the 
power  is  off.  The  Normal­Close  lock  is  closed  when  power  is  off.  The 
device supports both of the two kinds of locks at the same time. The way 
of  lock  connection  changes  with  the  type  of  lock.  For  NO  lock,  the  NO 
terminal will be used; for NC lock, the NC terminal will be used. 

When the DC  power electrical lock is connected to the  system,  you 


need  to  parallel  one  FR  107  diode  (Equipped  in  the  package)  to  prevent 
the self­inductance EMF affect the system, do not reverse the polarities 

This  access  control  device  is  powered  by  DC12V  and  the  work 
current is 400mA. If the lock work electric power is DC12V and the work 
current is less than 1000mA, the fingerprint device and lock are able to be 
powered by one adapter together, please refer to the table 1), 2).

11 
F11 Installation Guide V1.0 

In  the  following  three  cases,  we  recommend  that  fingerprint  device 
and lock are powered separately. 

1.  The  working  voltage  of  the  lock  is  DC12V,  but  the  current 
difference of the fingerprint device and the lock doesn’t exceed 1A. 

2. The lock voltage is not DC12V. 

3. The distance between lock and fingerprint device is too far. 

Lock Connection Diagram 

1) NC lock connection 

(The device and lock 

power by one adapter). 

2) NO lock connection 

(The device and lock 

power by one adapter).

12 
2. Installation 

3) NC lock connection 

(The device and lock 

powered by independent 

adapters). 

4) NO lock connection 

(The device and lock 

powered by independent 

adapters). 

2.3.4 Communication Mode 

The communication line should be as far as possible away from  the 
high voltage  wire.  It  should  not  be  parallel  with  the  power  cable,  do not

13 
F11 Installation Guide V1.0 

bundle them together. 

Terminals  Function 

RXD  RS232 Data Receiver 
TXD  RS232 Data Transmit 
GND  Ground 
485­  RS485­ 
485+  RS485+ 
RJ45­6 
RJ45­3 
Ethernet 
RJ45­2 
RJ45­1 

RS485 Communication Mode: 

1. While  using RS485 communication  mode, specified RS485 cable 


and active RS232/485 converter required, bus structure is recommended.

14 
2. Installation 

2.  If  RS485  communication  distance  is  over  300  meters,  add  a 
terminal  matched  resistor  (with  120Ω)  to  RS485  bus.  See  the  diagram 
below, add the resistor to 0# and 7# devices. 

2.3.5 Complementary Communications 

The  complementary  communications  such  as  Ethernet  and  RS232 


Mode, shown below.

15 
F11 Installation Guide V1.0 

1. Ethernet Mode: 

Connect the device with PC through crossover cable. 

2. Ethernet Mode: 

Using  the  straight  cable  to  connect  the  device  and  the  PC  to  the 
Switch/Hub. 

3. RS232 Mode:

16 
2. Installation 

2.3.6 Power Connections 

F11 power supply is 12VDC, standby current about 50mA, operating 
current of about 300mA, please use only approved the power adapter, the 
power  adapter  must  be  rated  for  the  product  and  for  the  voltage  and 
current  marked  on  the  product’s  electrical  rating,  otherwise  it  will  cause 
serious  damage.  (See  standard  connecting  figure).  Power  requirements: 
DC 12V (­ / + 2V) ­ 1A. 

?Note: F11 directly power on through the power supply of the access 
controller, can also be an external sources of power. 

The define of terminal connection: 

Terminals  Function 
GND  Cathode 
+12V  Positive    DC +12V 

2.4 Fixed the Device 
After  be  sure  all  cable  are  inserted  correctly  into,  fix  installed

17 
F11 Installation Guide V1.0 

backplane, and mount F11 on the backplane. 

?Note: Please strictly in accordance with the definition to connect, and 
connect  completed,  All  exposed  part  of  connection  wire  end  cannot  be 
exceeded  5mm  to  prevent  the  bared  wire  accidental  connection  which 
leads to device break  down.  in particular the red cable,  as a 12 V output 
voltage, when there is no an external card reader, in any case ensure to cut 
this cable and use the insulation adhesive plaster to dress it, so as to avoid 
short­circuit.

18 
3. Other Functions 

3. Other Functions 

3.1 Reset Button 

Due to  operation  error or other accidence, which leads the device 


not to work, you can restart device through reset key. 

1. Take a small tool which diameter is no more than 2mm. 

2. Find the “Reset” mark on the left of the small hole at the bottom 
of device, see following figure. 

3. Use the tool stick into the  hole refer to  the  picture below, then 


the device restart. 

Reset Button 

3.2 Tamper Switch 

The  tamper  switch  is  pressed  and  held  down  with  the  rear  cover. 
When the device is dismantled, the tamper switch will be lifted up and 
then it will send an signal to trigger an alarm. 

Clear alarm: The user can clear the alarm by unlocking the door 
upon successful verification.

19 
F11 Installation Guide V1.0 

Restore  factory  defaults:  The  factory  defaults  can  be  restored 


through the tamper switch. 

When  the  system  generates  an  alarm  for  30–60  seconds,  the  user 
can  press  the  tamper  switch  three  times  (Till  the  speaker  sounds)  to 
restore default settings, including the device number, system password, 
IP address, 485 address, and keyboard password. 

@  Tip:  The  user  information  stored  on  device  will  be  cleared 
after the device is restored to factory defaults, please be cautious. 

Tamper Switch 

3.3 Embed EM Card Reader (Optional) 

Embed  a  non­contact  EM  card  reader  module,  the  distance  of 


flashing card is 5­10cm. it completely supports the thick card (1.88mm), 
middle  card  (1.05mm),  and  thin  card  (0.88mm),  whose  operating 
frequency is at 125KHz, the card sensor area as following illustration.

20 
3. Other Functions 

3.4 Embed MIFARE Card Reader (Optional) 

Contain a non­contact MIFARE card reader module , the distance 
to  detect  card  is  5­10cm,  it  completely  supports  MIFARE  cards  that 
provide  operating  frequency  13.56MHZ,  communication  speed 
106KBPS, the card sensor area is as following illustration.

Card Sensor Area 

21 
4. Trouble Shooting 

4. Trouble Shooting 
Trouble  Cause & Measure 
Cause: No power or lack of voltage. 
Measure: 
①Check  and  examine  the  connection  of  PWR, 
Power LED is off 
GND, make sure they contact well. 
②Measure  the  supply  voltage,  ensure  that  it  is 
12VDC. 
Cause: 
①The connection problem. 
②Communication parameters not configure right, 
such  as  IP  address  RS232/  RS485  baud  rate, 
Device is unable  system password, etc. 
to connect with  Measure: 
PC  ①Check  and  examine  the  connection  of 
RS232/RS485 or TCP/IP, whether its connection is 
correct or not. 
②Change  the  communication  mode  to  connect 
with PC, and check the parameters. 
Cause: 
①For long time used, surface of fingerprint sensor 
becomes  dirty,  or  there  are  some  scratches  on  it, 
After the power 
the  device  takes  it  as  a  fingerprint  and  does 
is on, the device 
verification. 
cycles reboot 
②Fingerprint  connection  cable  of  fingerprint 
sensor is loosed. 
③ Chip­on­board is broken.

22 
4. Trouble Shooting 

④Lack of power. 
Measure: 
①Under  such  situation  you  can  use    scotch 
tape to adhere the dirt. 
②, ③Need to contact suppler and apply for repair. 
④Use a multimeter to measure the power voltage. 
Cause: 
①Fingerprint connection cable is broken. 
②Fingerprint sensor broke down. 
The fingerprint 
Measure: 
sensor light is off 
①Please take out the FFC from slot of fingerprint 
sensor, plug it again. 
②Contact suppler, apply for repair. 
Cause : 
①communication  distance  between  fingerprint 
reader and access controller is too long 
Wiegand output  ②Poor communications environment 
problems:  ③Access  Controllers  request  fingerprint  reader 
After correctly  have a stronger signal drive capability 
match fingerprint  ④ Output  circuit  damage, put a  multimeter to  DC 
or swipe card, the  profile  and  measure  WD0,  WD1  pins,  when 
controller can not  verification successful, two pins voltage is subject 
accept the card  to  fluctuations,  without  fluctuations  or  0  V,  the 
number or  circuit has proved damage. 
numbers error.  Measure: 
①Communications  distance  between  fingerprint 
reader  and  access  controller  is  no  more  than  100 
meters,  longer  distance  need  to  connect

23 
conversion circuit 
②Improve  communications    environment,  use  a 
better  shielding  cable  to  reduce  external 
interference. 
③Modify  the  WIEGAND  output  signal  of  the 
fingerprint  reader,  adjust  the  low­pulse  cycle  to 
500us,  adjusted  the  cycle  to  2ms.  Then  add  the 
resistance  to  offset  the  access  controller’s  input 
pull­up resistor. 
④Contact with the vendor for warranty. 
Cause: 
①RS485 communications line connection wrong. 
②Communications  baud  rate  is  too  high  (In  the 
proposed multiple device networking as 9600) 
③Too  long  distance  of  communication  or  poor 
environment 
④  Among  network,  a  RS485  chip  of  the 
fingerprint  reader  damaged,  that  caused  the 
Failed RS485  network  paralysis. 
communication  ⑤Two machines have the same IP address. 
⑥Too  many  devices  over  the  network will  affect 
the communication distance and the RS485 signal 
stability. 
⑦ RS232/485  converters  drive  capability  no 
enough. 
Measure: 
①The theory longest distance between fingerprint 
reader  and  access  controller  is  1,200  meters

24 
4. Trouble Shooting 

(Actual apply is not recommended more than 500 
meters), longer distance than add repeaters. 
②Communication baud rate adjust to 9600. 
③Add  the  terminal  matched  resistance  to  RS485 
bus  in  the  starting  terminal  and  the  end  terminal, 
resistance is about 120  Ω. 
④  Improve  communications  surrounding 
environment,  use  a  good  shielding  cable  and 
smaller  distributed  capacitance  wires  to  reduce 
external interference. 
⑤Cut  off  the  power  of  fingerprint  reader  one  by 
one to position the failure terminal. 
⑥  Reducing  the  number  of  machines,  or 
increasing  RS232/485  converter  or  RS485 
network/ 
⑦Recommend to use active RS232/485 converter.