ZBL-P8100 Foundation Pile Dynamic Detector
Field of Use
The P8100 Foundation Pile Dynamic Detector is used to assess the integrity of concrete pile and
identify the extent and location of the pile defects by using reflected wave method.
It can be used for testing bored concrete pile and hammer pile and also for testing the structures
with exposed top surface such as pillars.
Basic Principle
Hit the top of pile with testing hammer to produce stress wave,
and the wave may reflect when it meets defect (pile bottom, crack, or
soil middle layer) while it run downward through the concrete. The
probe placed on the top of the pile receives the reflected signal. The
instrument digitally processes the signal in order to judge the quality
of foundation pile. According to the time interval between the arrival
of the direct wave and first reflected wave, or time interval between
the two continuous reflected waves, the depth of foundation pile can
be determined by the following equation: D= VP×TP/2
(D - depth of foundation pile, VP – compression wave speed, TP - compression wave spread time)
Features
Two-channel design can measure reflected wave speed accurately, and it can collect reflected
wave at two places.
True 24 bit A/D data acquisition provides high resolution waveform avoiding the noise and
signal distortion.
1MHz high-speed data acquisition makes the minimum sampling time resolution reach 1us,
providing more useful information and contributing to the discovery of shallow defects.
High Brightness and TFT colorful LCD screen.
Store waveform images for each tested pile.
New wavelet processing method can effectively judge the integrity of foundation pile in
complex situation.
Water-proof; protection class reaches IP65.
Key and touch screen
Technical parameters
Item Specifications
Model ZBL-P8100
Control Mode A8 Embedded platform
Screen 5.7 inch、High brightness, TFT color LCD screen
Data Storage ≥4GB
Operation Mode key+touch screen
Sentinel magnify (time) 1、2、5、10、20、50、100 adjustable
A/D resolution (bit) true 24 bits A/D
Sampling time intervals(μs) 1~64000 adjustable
Max length of sampling 4096
Trigger Signal trigger,
Noise voltage of the system (mV) ≤1
Dynamic range(dB) ≥184
Amplifier frequency range(Hz) 10~10k
Max storage length 4096
Amplitude nonlinear degree ≤10%
Time value error ≤1%
Time resolving power(us) 1
Gain error(dB) ≤1
Continuous working time(h) >5
Number of channels 2
Interference between the channels ≤1%
Transducer/Probe Sensitivity
≥100
(acceleration mode)(mv/g)
Frequency range of Probe
0.5 ~ 9000
(Acceleration probe) (Hz)
Transmission port double USB
Wi-fi yes
Built-in battery
Power
Outside 220V AC/DC
Weight(kg) 1.3(lithium battery included)
Size(mm) 210×149×60
Operational Temperature(℃) -10 ~+50
evvironment Humidity(RH) < 90%