Catalogo Regulador Gas Natural
Catalogo Regulador Gas Natural
c o m
GENERAL
CATALOGUE
ESKA VALVE is gas equipment producer (Gas Pressure Regulators, Gas Filters and Valves) in Turkey since 1968. Our
certified products are being used in civic and industrial areas all around the world.
For 50 years, our product portfolio, operations and ESKA VALVE family has grown and still keep growing. Ingenuity,
reliability and hard work led us to be the market leader in Turkey and expanded our international operations in more than
30 countries in global scale. By the time you read this text , probably we will be reaching out another locations and placing
our products into grids.
By examining, following and applying 133 national and international standards from our R&D Department library, and
with our Quality Department’s deep commitment to test each and every product on over 100 inspection-test points have
made us to produce annually more than 1.000.000 accurate and reliable unit products which 52 gas distribution companies
trust worldwide .
Hope to gain your trust and see you in our ever-growing family.
ERG-H7 ERG-H6 ERG-H5
SERIES SERIES SERIES
Page 05 - 09 Page 10 - 14 Page 15 - 19
ERG-SE ERG-SR E R G
SERIES SERIES SERIES
Page 35 - 49 Page 40 - 44 Page 46 - 50
E G F EGF-H E M V
SERIES SERIES SERIES
Page 65 - 69 Page 70 - 72 Page 74 - 78
E G V E A C CABINET
SERIES SERIES SOLUTIONS
Page 80 - 84 Page 85 - 86 Page 87 - 92
DIRECT ACTING
GAS PRESSURE REGULATOR
w w w. e s k a v a l v e . c o m
ERG-H7
SERIES
ERG-H7
SERIES
ERG-H7 Series pressure regulator is used on gas line to reduce inlet pressure to desired outlet pressure.
It is mainly used in Distribution of Natural Gas and also suitable to use with non-corrosive gases. ERG-H7 is a
single stage direct acting regulator with a optional security systems such as relief valve UPSO and OPSO
FEATURES
• For medium and high pressure domestic or industrial second group gas lines.
• Max inlet pressure 0,2 to 16 bar.
• Max outlet pressure 20-4000 mbar.
• Outlet pressure tolerance is ±%5-10 (AC5 & AC10)
• Lock up pressure tolerance is max +%10 (SG30 and SG20 is possible also)
• Can be integrated with UPSO & OPSO
• Temperature class as a standard -20 to +60 Celcius Degree. Low temperature series has ability to
work under as low as -40 Celcius Degree.
• Flow direction inline type.
CONFIGURATIONS
INLINE TYPE
06
ERG-H7
SERIES
DIMENSIONS
C
K
B
A
DN
DN
E
ERG-H7 LP 50 244 428 G 1/2” 380 109 254 559 451 G 1/2”
ERG-H7 HP 50 244 428 G 1/2” 380 109 254 567 459 G 1/2”
ERG-H7 LP 80 289 421 G 1/2” 380 132 298 583 475 G 1/2”
ERG-H7 HP 80 289 421 G 1/2” 380 132 298 592 484 G 1/2”
07
ERG-H7
SERIES
OPSO - UPSO
SAFETY AND ACCESSORIES
Over Pressure Shut-Off System
OPSO system is very useful during major
breakdown situations and keeps
the customer side safe. System works
as a security valve and activates itself
when the outlet pressure passes OPSO
calibration point. OPSO system cuts the
gas off, and manual reset is needed to
activate the regulator again.
08
ERG-H7
SERIES
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60°C (optional : -40… +60°C)
Maximum inlet pressure : 16 bar
Outlet pressure range : 20 mbar to 4 bar
Fail Mode : Fail to Open
DN : 2” (50) - 3" (80)
DESIGN
The ERG-H7 Series pressure regulator body consists of :
• Valve housing
• Set up tool
• Breather consol.
• Over pressure shut off OPSO
• Under pressure shut off UPSO
• Furthermore the truly “top entry design” allows an easy periodical maintenance without removing body from
the line.
• High flow rate coefficient
• High accuracy, even at maximum flow rates
• Reduced response times,
• Periodical maintenance without disassembling the body from the pipework,
MATERIALS
• Body is ductile cast iron
• Rubber components have gas approval according to EN 549
• Head covers is die cast alluminium EN AC-AISI 12
09
w w w. e s k a v a l v e . c o m
ERG-H6
SERIES
ERG-H6
SERIES
ERG-H6 Series pressure regulator is used on gas line to reduce inlet pressure to desired outlet pressure.
It is mainly used in Distribution of Natural Gas and also suitable to use with non-corrosive gases. ERG-H6 is a
single stage direct acting regulator with a optional security systems such as relief valve UPSO and OPSO
FEATURES
• For medium and high pressure domestic or industrial second group gas lines.
• Max inlet pressure 0,3 to 20 bar.
• Max outlet pressure 15-4000 mbar.
• Outlet pressure tolerance is ±%5-10 (AC5 & AC10)
• Lock up pressure tolerance is max +%10 (SG30 and SG20 is possible also)
• Can be integrated with Relief valve & UPSO & OPSO
• Temperature class as a standard -20 to +60 Celcius Degree. Low temperature series has ability to
work under as low as -40 Celcius Degree.
• Flow direction inline type.
CONFIGURATIONS
INLINE TYPE
11
ERG-H6
SERIES
DIMENSIONS
K
B
L
A
DN DN
DN A B C D E F K L
12
ERG-H6
SERIES
13
ERG-H6
SERIES
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60°C (optional : -40… +60°C)
Assembly : Vertical and Horizontal Position
Maximum inlet pressure : 20 bar
Outlet pressure range : 21 mbar to 4 bar
Conforming : 2014/68/EU
Type : IS
Fail Mode : Fail to Open
DN : 1” (25) - 1”1/2 (40) - 2” (50)
DESIGN
The ERG-H6 Series pressure regulator body consists of :
• Valve housing
• Set up tool
• Breather consol.
• Over pressure shut off OPSO
• Under pressure shut off UPSO
• Furthermore the truly “top entry design” allows an easy periodical maintenance without removing body from
the line.
• High flow rate coefficient
• High accuracy, even at maximum flow rates
• Reduced response times,
• Periodical maintenance without disassembling the body from the pipework,
MATERIALS
• Body is ductile cast iron
• Rubber components have gas approval according to EN 549
• Orifice is Brass
• Head covers is die cast alluminium EN AC-AISI 12
CAPACITIES
LP Version MP Version
Norminal Diameter 25 40 50 25 40 50
CG Flow Coffivient 275 665 792 326 704 781
KG Flow Coffivient 290 695 833 343 739 820
K1 Body Shape Factor 98 98 91 101 98 100
Sizing of regulators is usually made on the basis of Cg valve and KG flow rate coeffcients. Flow rates at the fully open position and the various operating
When the Cg and KG values of the regulator are known, as well as Pe and Pa, the flow rate can be calculated as
follows:
1- in non-critical conditions: (Pe < 2 x Pa)
Pe - Pa
Q = 0,52 x Cg x Pe x sen (K1 x ) Q = KG x Pa x (Pe - Pa)
Pe
KG
Q= x Pe
2
Q = 0,52 x Cg x Pe
14
w w w. e s k a v a l v e . c o m
ERG-H5
SERIES
ERG-H5
SERIES
ERG-H5 Series pressure regulator which is used on gas line to reduce inlet pressure to desired outlet pressure.
ERG-H5 series pressure regulators are suitable for commercial usage like Gas Skids where the maximum inlet
pressure up to 20 bar and outlet pressure up to 2,5 bar.
It is mainly used in Distribution of Natural Gas and also suitable to use with non-corrosive gases. ERG-H5 is a single
stage direct acting regulator with a optional security systems such as relief valve UPSO and OPSO
FEATURES
• For medium and high pressure domestic or industrial second group gas lines.
• Max inlet pressure 1 to 20 bar.
• Max outlet pressure LPO : 15 to 100 mbar MPO : 100 to 300 mbar HPO : 300 to 2,5 bar
• Optional filter on inlet.
• Outlet pressure tolerance is ±%5-10 (AC5 & AC10)
• Lock up pressure tolerance is max +%30 (SG30,SG10 and SG20 is possible also)
• Can be integrated with Relief valve & UPSO & OPSO
• Temperature class as a standard -20 to +60 Cantigrade Degree. Low temperature series has ability to work
under as low as -40 Centigrade Degree.
• Flow direction inline
CONFIGURATIONS
INLINE TYPE
16
ERG-H5
SERIES
DIMENSIONS
MODEL A B C D E MODEL A B C D E
ERG-H5 (1” - 1”) 100 249 402 1” 1” ERG-H5 (1”-1 1/2”) 129 254 411 1” 1 1/2”
CONNECTION TYPES
OPSO - UPSO
Over Pressure Shut-Off System
OPSO system is very useful during major
breakdown situations and keeps the
customer side safe. System works as a
security valve and activates itself when the
outlet pressure passes OPSO calibration
point. OPSO system cuts the gas off, and
manual reset is needed to activate the
regulator again.
System has an independent shut-off
mechanism and orifice and it monitors
outlet pressure changes continuously, so
activation time is below 2 seconds.
18
ERG-H5
SERIES
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60°C (optional : -40… +60°C)
Assembly : Vertical and Horizontal Position
Maximum inlet pressure : 6 bar (Optional 10 bar, 20 bar)
Outlet pressure range : 15 mbar to 2,5 bar
Conforming : 2014/68/EU
Filter : As a standard 100 micron pore diameter.
DESIGN
The ERG-H5 Series pressure regulator body consists of :
• Valve housing
• Internal thread
• Filter
• Set up tool
• Breather consol.
• Over pressure shut off OPSO
• Under pressure shut off UPSO
• Integrated bypass
MATERIALS
• Body Steel or Iron
• Rubber components have gas approval according to EN 549
• Brass materials are suitable according to EN12164 - EN12165 Standard.
MODELS / CAPACITIES
1"-1" WITH INTERNAL SENSING LINE ACTIVE 1"-1" WITH INTERNAL AND EXTERNAL SENSING LINE ACTIVE
Outlet Pressure 15-100 mbar Outlet Pressure 100-300 mbar Outlet Pressure 15-100 mbar Outlet Pressure 100-300 mbar
LP Version MP Version LP Version MP Version
Inlet Pressure AC5 AC10 AC20 Inlet Pressure AC5 AC10 AC20 Inlet Pressure AC5 AC10 AC20 Inlet Pressure AC5 AC10 AC20
1"-1 1/2" WITH INTERNAL SENSING LINE ACTIVE 1"-1 1/2" WITH INTERNAL AND EXTERNAL SENSING LINE ACTIVE
Outlet Pressure 15-100 mbar Outlet Pressure 100-300 mbar Outlet Pressure 15-100 mbar Outlet Pressure 100-300 mbar
LP Version MP Version LP Version MP Version
Inlet Pressure AC5 AC10 AC20 Inlet Pressure AC5 AC10 AC20 Inlet Pressure AC5 AC10 AC20 Inlet Pressure AC5 AC10 AC20
Outlet 70 90 100 Outlet 110 140 160 Outlet 65 100 105 Outlet 90 150 170
Pressure+0,5bar Pressure+0,5bar Pressure+0,5bar Pressure+0,5bar
Outlet 150 170 190 Outlet 160 240 270 Outlet 150 160 170 Outlet 150 230 270
Pressure+1bar Pressure+1bar Pressure+1bar Pressure+1bar
Outlet 130 190 190 Outlet 340 370 400 Outlet 280 330 330 Outlet 500 500 500
Pressure+2,5bar Pressure+2,5bar Pressure+2,5bar Pressure+2,5bar
Outlet 120 150 170 Outlet 340 400 450 Outlet 190 235 280 Outlet 500 500 500
Pressure+5bar Pressure+5bar Pressure+5bar Pressure+5bar
19
w w w. e s k a v a l v e . c o m
ERG-H1
SERIES
ERG-H1
SERIES
ERG-H1 Series pressure regulator is used on gasline to reduce inlet pressure to desired outlet pressure.
ERG-H1 series pressure regulators are suitable for commercial usage like Gas Skids where the maximum inlet pres-
sure up to 20 bar and outlet pressure up to 4bar.
It is mainly used in Distribution of Natural Gas and also suitable to use with non-corrosive gases. ERG-H1 is a single
stage regulator with an optional security systems such as relief valve, UPSO and OPSO.
The regulators are manufactured according to Ped Directive 2014/68/EU. The performance of the regulators
complies with EN 334
FEATURES
• For medium and high pressure domestic or industrial second group gas lines.
• Max inlet pressure 1 to 20 bar.
• Max outlet pressure MPO: 100 to 800 and HPO : 800 to 4 bar.
• Optional filter on inlet.
• Outlet pressure tolerance is ±%5-10 (AC5&AC10)
• Lock up pressure tolerance is max +%30 (SG30)
• Can be integrated with Relief valve & UPSO & OPSO
• Flow direction inline and angle type.
DIMENSIONS
21
ERG-H1
SERIES
CONFIGURATIONS
CONNECTION TYPES
23
ERG-H1
SERIES
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60°C (optional : -40… +60°C)
Assembly : Vertical and Horizontal Position
Maximum inlet pressure : 6 bar (Optional 10 bar, 20 bar)
Outlet pressure range : 100 mbar to 4 bar.
Conforming : 2014/68/EU
Filter : As a standard 100 micron pore diameter.
DESIGN
The ERG-H1 Series pressure regulator body consists of :
• Valve housing
• Internal thread
• Filter
• Set up tool
• Breather consol.
• Optional pressure test point.
• Over pressure shut off OPSO
• Under pressure shut off UPSO
• Integrated bypass
MATERIALS
• Body Aluminum
• Rubber components have gas approval according to EN 549
• Brass materials are suitable according to EN12164 - EN12165 Standard.
CAPACITIES
75 Pd + 0,5 bar
100 Pd + 1 bar
Pd = Outlet pressure
24
DOUBLE STAGE
GAS PRESSURE REGULATOR
w w w. e s k a v a l v e . c o m
ERG-SX
SERIES
ERG-SX
SERIES
ERG-SX Series double stage pressure regulator is used on gas line to reduce inlet pressure to desired outlet pressure.
It is suitable for both commercial and domestic usage where can be directly installed to gas meters with high operation-
al reliability and accurate outlet pressure accuracy.
Simple installation procedure.
Due to different inlet and outlet connection range, ERG-SX Series can be used along with pipe diameter from DN15 to
DN50 with different thread standards as well as BSP, BSPT, NPT, NPP.
The modular concept of ERG-SX and wide range availability of inlet and outlet connections allow to match particular
customer requirements.
The regulators are manufactured according to Ped Directive 2014/68/EU. The functional tests are performed
according to EN334.
FEATURES
• For medium pressure domestic or commercial second group gas lines.
23
• Optional metallic mesh filter for easy change and guarantees longer operation life of regulator.
• Outlet pressure tolerance is +%10 (AC10) up +- %5 (AC5)
• Lock-up pressure tolerance is +%20 (SG20) up to 100 mbar outlet pressure, more than 100 mbar
outlet pressure SG20 and SG10 possible.
• Up to 6 bar inlet pressure.
• 18 - 500 mbar outlet pressure range with interchangeable springs
Optional ;
• Incorporated Under Pressure Shut Off Valve.
• Internal Relief Valve
DIMENSIONS
27
ERG-SX
SERIES
28
ERG-SX
SERIES
CONFIGURATIONS
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60°C (optional : -40… +60°C)
Assembly : Vertical and Horizontal Position
Maximum inlet pressure : 5 bar
Minimum inlet pressure : Depending on customer request can start as low as 0,3 bar.
Outlet pressure range : 12 to 35 mbar.
Filter : Included
DESIGN
The ERG-SX Series pressure regulator body may consists of:
• Valve housing
• Connections
• Filter
• Ventilation console
• Outlet pressure test point
• Integrated security valves (UPSO / Relief)
MATERIALS
• Body and covers Aluminum according to EN1706 standard.
• Rubber components are Nitril Rubber comply to EN 549.
• Brass materials are suitable according to EN12164 - EN12165 Standard.
• Filter material is metallic mesh filter.
MODELS
MODEL FLOW RATE UNIT WEIGHT BOX SIZE PACKAGING CARTON SIZE CARTON TOTAL CARTON
LPO MPO HPO (kgs) (LxWxH cm) (pieces/ carton) (LxWxH cm) (weight) (weight)
18-75 75-150 150-500
mbar mbar mbar
29
w w w. e s k a v a l v e . c o m
ERG-S
SERIES
ERG-S
SERIES
ERG-S Series double stage pressure regulator is used on gas line to reduce inlet pressure to desired outlet pressure.
It is suitable for both commercial and domestic usage where can be directly installed to gas meters with high operation-
al reliability and accurate outlet pressure accuracy.
Simple installation procedure.
Due to different inlet and outlet connection range, ERG-S Series can be used along with pipe diameter from DN15 to
DN50 with different thread standards as well as BSP, BSPT, NPT, NPP.
The modular concept of ERG-S and wide range availability of inlet and outlet connections allow to match particular
customer requirements.
The regulators are manufactured according to Ped Directive 2014/68/EU. The functional tests are performed
according to EN334.
FEATURES
• For medium pressure domestic or commercial second group gas lines.
• Optional metallic mesh filter for easy change and guarantees longer operation life of regulator.
• Outlet pressure tolerance is +%10 (AC10) up +- %5 (AC5)
• Lock-up pressure tolerance is +%20 (SG20) up to 100 mbar outlet pressure, more than 100 mbar
outlet pressure SG20 and SG10 possible.
• Up to 6 bar inlet pressure.
• 18 - 500 mbar outlet pressure range with interchangeable springs
Optional ;
• Incorporated Under Pressure Shut Off Valve.
• Internal Relief Valve
DIMENSIONS
31
ERG-S
SERIES
CONNECTION TYPES
BSPP
G 1/4”
G 1/2”
G 3/4”
G 1”
G 1 1/4”
G 1 1/2”
BSPT
R 1/4”
R 1/2”
R 3/4”
R 1”
R 1 1/4”
R 1 1/2”
ANSI B 1.20.1
NPT 1/4”
NPT 1/2”
NPT 3/4”
NPT 1”
NPT 1 1/4”
NPT 1 1/2”
1/2" Tapa 1/2" CF 3/4" SC 3/4" CF 7/8" 1" FC (Female) 1'' CF 1 1/4" CF
3 3 17
3 15.5 3 16.4 16.4
3 16 12.3
INLET
7.3
G1/2"
7/8"
3/4"
G1''
1 1/4"
3/4"
1/2"
3/4" Tapa 1/2" CF 3/4" CF 7/8" 1'' CF 1" FC (Female) 1 1/4" CF 1 1/4" CF
18.5
19.4
C=59.1
17
C=58
C=60
C=59.9
C=60
C=46.6
C=60
19.4
C=73
19.4
32.4
19.4
6
7/8" 1"
3
OUTLET
1/2" G 1''
3/4"
D=26.8 22.4
D=44 18.5 3 19.4 3
3
1/2"
3/4"
G 1''
7/8"
0 17 3 D=45.3
D=46.2 D=49
32
ERG-S
SERIES
CONFIGURATIONS
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60°C (optional : -40… +60°C)
Assembly : Vertical and Horizontal Position
Maximum inlet pressure : 6 bar
Minimum inlet pressure : Depending on customer request can start as low as 0,1 bar.
Outlet pressure range : 18 to 500 mbar.
Filter : Included
DESIGN
The ERG-S Series pressure regulator body may consists of:
• Valve housing
• Connections
• Filter
• Ventilation console
• Outlet pressure test point
• Integrated security valves (UPSO / Relief)
MATERIALS
• Body and covers Aluminum according to EN1706 standard.
• Rubber components are Nitril Rubber comply to EN 549.
• Brass materials are suitable according to EN12164 - EN12165 Standard.
• Filter material is metallic mesh filter.
MODELS
MODEL FLOW RATE UNIT WEIGHT BOX SIZE PACKAGING CARTON SIZE CARTON TOTAL CARTON
LPO MPO HPO (kgs) (LxWxH cm) (pieces/ carton) (LxWxH cm) (weight) (weight)
18-75 75-150 150-500
mbar mbar mbar
BESIDE STANDARD FLOW RATES ABOVE, 1,6 / 2,5 / 15 / 30 / 40 / 60 / 65 SCMH ARE AVAILABLE UPON REQUEST.
34
w w w. e s k a v a l v e . c o m
ERG-SE
SERIES
ERG-SE
SERIES
ERG-SE Series double stage pressure regulator is used on gas line to reduce inlet pressure to desired outlet pressure.
It is suitable for both commercial and domestic usage where can be directly installed to gas meters with high opera-
tional reliability and accurate outlet pressure accuracy.
Simple installation procedure.
Due to different inlet and outlet connection range, ERG-SE Series can be used along with pipe diameter from DN15 to
DN50 with different thread standards as well as BSP, BSPT, NPT, NPP.
The modular concept of ERG-SE and wide range availability of inlet and outlet connections allow to match particular
customer requirements.
The regulators are manufactured according to Ped Directive 2014/68/EU. The functional tests are performed
according to EN334.
FEATURES
• For medium pressure domestic or commercial second group gas lines.
• Optional metallic mesh filter for easy change and guarantees longer operation life of regulator.
• Outlet pressure tolerance is +%10 (AC10) up +- %5 (AC5)
• Lock-up pressure tolerance is +%20 (SG20) up to 100 mbar outlet pressure, more than 100 mbar outlet
pressure SG20 and SG10 possible.
• Up to 6 bar inlet pressure.
• 18 - 500 mbar outlet pressure range with interchangeable springs
Optional ;
• Incorporated Over Pressure Shut Off Valve.
• Incorporated Under Pressure Shut Off Valve.
• Internal Relief Valve
DIMENSIONS
36
ERG-SE
SERIES
CONNECTION TYPES
BSPP
G 1/4”
G 1/2”
G 3/4”
G 1”
G 1 1/4”
G 1 1/2”
BSPT
R 1/4”
R 1/2”
R 3/4”
R 1”
R 1 1/4”
R 1 1/2”
ANSI B 1.20.1
NPT 1/4”
NPT 1/2”
NPT 3/4”
NPT 1”
NPT 1 1/4”
NPT 1 1/2”
1/2" Tapa 1/2" CF 3/4" SC 3/4" CF 7/8" 1" FC (Female) 1'' CF 1 1/4" CF
3 3 17
3 15.5 3 16.4 16.4
3 16 12.3
INLET
7.3
G1/2"
7/8"
3/4"
G1''
1 1/4"
3/4"
1/2"
3/4" Tapa 1/2" CF 3/4" CF 7/8" 1'' CF 1" FC (Female) 1 1/4" CF 1 1/4" CF
18.5
19.4
C=59.1
17
C=58
C=60
C=59.9
C=60
C=46.6
C=60
19.4
C=73
19.4
32.4
19.4
6
7/8" 1"
3
OUTLET
1/2" G 1''
3/4"
D=26.8 22.4
D=44 18.5 3 19.4 3
3
1/2"
3/4"
G 1''
7/8"
0 17 3 D=45.3
D=46.2 D=49
37
ERG-SE
SERIES
CONFIGURATIONS
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60°C (optional : -40… +60°C)
Assembly : Vertical and Horizontal Position
Maximum inlet pressure : 6 bar
Minimum inlet pressure : Depending on customer request can start as low as 0,1 bar.
Outlet pressure range : 18 to 500 mbar.
Filter : Included
DESIGN
The ERG-SE Series pressure regulator body may consists of:
• Valve housing
• Connections
• Filter
• Ventilation console
• Outlet pressure test point
• Integrated security valves (OPSO / UPSO / Relief)
MATERIALS
• Body and covers Aluminum according to EN1706 standard.
• Rubber components are Nitril Rubber comply to EN 549.
• Brass materials are suitable according to EN12164 - EN12165 Standard.
• Filter material is metallic mesh filter.
MODELS
MODEL FLOW RATE UNIT WEIGHT BOX SIZE PACKAGING CARTON SIZE CARTON TOTAL CARTON
LPO MPO HPO (kgs) (LxWxH cm) (pieces/ carton) (LxWxH cm) (weight) (weight)
18-75 75-150 150-500
mbar mbar mbar
BESIDE STANDARD FLOW RATES ABOVE, 1,6 / 2,5 / 15 / 30 / 40 / 60 / 65 SCMH ARE AVAILABLE UPON REQUEST.
39
w w w. e s k a v a l v e . c o m
ERG-SR
SERIES
ERG-SR
SERIES
ERG-SR Series pressure regulator is used on gas line to reduce inlet pressure to desired outlet pressure. It is
suitable for both commercial and residential usage where can be directly installed to gas meters with high
operational reliability and accurate outlet pressure accuracy.
Simple installation procedure. Direction of the line can be inline or angle.
Due to different inlet and outlet connection range, ERG-SR Series can be used along with pipe diameter from
DN20 to DN50 with different thread standards as well as BSP, BSPT, NPT, NPP. (Also, can be added to flange
connection.)
The regulators are manufactured according to Ped Directive 2014/68/EU. The functional tests are performed
according to EN334.
FEATURES
• For medium pressure domestic or commercial second group gas lines.
• Optional metallic mesh filter for easy change and guarantees longer operation life of regulator.
• Outlet pressure tolerance is +%10 (AC10) up +- %5 (AC5)
• Lock-up pressure tolerance is +%20 (SG20) up to 100 mbar outlet pressure, more than 100 mbar outlet
pressure SG20 and SG10 possible.
• Up to 6 bar inlet pressure.
• 15 - 360 mbar outlet pressure range with interchangable springs
• OPSO pressure range 35 - 520 mbar
• UPSO pressure range 8 - 250 mbar
CONFIGURATIONS
41
ERG-SR
SERIES
DIMENSIONS
CONNECTION TYPES
42
ERG-SR
SERIES
SPECIFICATIONS
Medium : Natural Gas, LPG and Non-Corrosive Gases
Operating temperature : -20… + 60 °C (optional : -40… +60 °C)
Assembly : Vertical and Horizontal Position
Maximum inlet pressure : 6 bar
Outlet pressure range : 15 to 360 mbar.
Referring : Ped 2014/68/EU
Filter : Included
DESIGN
The ERG-SR Series pressure regulator body consists of:
• Loose nut or body thread or flanged connection
• Filter
• Ventilation console
• Outlet pressure test point
• Integrated security valves
MATERIALS
• Body and covers Aluminum comply with EN1706 standard.
• Rubber components comply with EN549.
• Brass materials comply with EN12164 Standard.
• Filter material is metallic mesh filter.
MODELS
44
SINGLE STAGE
GAS PRESSURE REGULATOR
w w w. e s k a v a l v e . c o m
E R G
SERIES
E R G
SERIES
INTRODUCTORY
ERG series gas pressure regulators are used in the gas lines in order to reduce maximum 1 bar input pressure to the
desired output pressure between 16 and 150 mbar. The range of the output pressure can be set with the choice of a
different spring.
47
E R G
SERIES
TECHNICAL INFORMATION
ERG 1015
100 ERG 1020
ERG 1025
50 ERG 1032
ERG 1040
ERG 1050
10
P mbar
Convertion Constant
1 Methane : 1,28
LPG : 1,61
0,1
10 50 100 200 300 500 1000
Q (Air) SCMH
48
E R G
SERIES
CONFIGURATIONS
INLINE
INLINE
1/2" 20 m3/h
3/4" 25 m3/h
1" 35 m3/h
11/4" 85 m3/h
FLOW RATE TABLE (FOR NATURAL GAS) AT INLET PRESSURE 300 mbar ACCURACY CLASS AC10
49
E R G
SERIES
DIMENSIONS
MODEL A B C D E F
MODEL A B C D E
50
w w w. e s k a v a l v e . c o m
ERG-E
SERIES
ERG-E
SERIES
INTRODUCTORY
ERG-E series gas pressure regulators are used in the gas lines in order to reduce maximum 1 bar input pressure to
the desired output pressure between 16 and 150 mbar. The range of the output pressure can be set with the choice of a
different spring. The regulator with safety stopping gets automatically active and stops the gas flow in case that the input
pressure gets higher or lower than the adjusted value in order to ensure the safety of the devices used in the system
thanks to the safe stopping system it includes.
52
ERG-E
SERIES
TECHNICAL INFORMATION
ERG-E 1015
100 ERG-E 1020
ERG-E 1025
50 ERG-E 1032
ERG-E 1040
ERG-E 1050
10
P mbar
Convertion Constant
Methane : 1,28
1
LPG : 1,61
0,1
10 50 100 200 300 500 1000
Q (Air) SCMH
53
ERG-E
SERIES
INLINE
1/2" 20 m3/h
3/4" 25 m3/h
1" 35 m3/h
11/4" 85 m3/h
FLOW RATE TABLE (FOR NATURAL GAS) AT INLET PRESSURE 300 mbar ACCURACY CLASS AC10
54
ERG-E
SERIES
DIMENSIONS
MODEL A B C D E F
MODEL A B C D E
55
w w w. e s k a v a l v e . c o m
ERG-H
SERIES
ERG-H
SERIES
INTRODUCTORY
ESKA ERG-H series gas pressure regulators are used in the gas lines in order to reduce maximum 5 bar input pressure to the
desired output pressure between 16 and 500 mbar. The range of the output pressure can be set with the choice of different
springs.
The regulators are manufactured according to Ped Directive 2014/68/EU. The functional tests are performed according to
EN334.
CONFIGURATIONS
57
ERG-H
SERIES
TECHNICAL INFORMATION
• Material Standard : Aluminum-EN 1706 / Brass-EN 12164 and EN 12165 / Rubber-EN 549
• According to Directives : 2014/68/EU
• Capacity : Up to 1000m3/h
58
ERG-H
SERIES
DIMENSIONS
MODEL A B C D E
MODEL A B C D E
ERG-EH
SERIES
ERG-EH
SERIES
INTRODUCTORY
ERG-EH series gas pressure regulators are used in the gas lines in order to reduce maximum 5 bar input pressure to
the desired output pressure between 16 and 500 mbar. The range of the output pressure can be set with the choice of a
different spring. The regulator with safety stopping gets automatically active and stops the gas flow in case that the input
pressure gets higher or lower than the adjusted value in order to ensure the safety of the devices used in the system
thanks to the safe stopping system it includes.
CONFIGURATIONS
INLINE
INLINE
61
ERG-EH
SERIES
TECHNICAL INFORMATION
62
ERG-EH
SERIES
DIMENSIONS
MODEL A B C D E
MODEL A B C D E
E G F
SERIES
E G F
SERIES
INTRODUCTORY
EGF model gas filters are the elements that seperates the dust particles carried by the gas or very small particles
spread within the gas (for example: dust and rust), holds these and protects the burner, gas counter and adjustment
devices which may possibly be damaged. Dust, woodchips, smut and other physical substances and dirt in the gas are held
by the fiber. When the dust tank capacity is exceeded or a very high pressure difference effected, the filter loses its filter
protection function. The filters are resistant against the mechanical and thermal stress that occur under operational
conditions.The device must be kept away from rain and water as much as possible.
66
E G F
SERIES
TECHNICAL INFORMATION
• Filter : Pore dimensions as standard 50
• Usage : City gas networks and gas
micron (10-20 microns on
pipelines in industrial areas
request)
• Fluid Type : Non‐corrosive gases such as
• Ambient
Natural Gas (Methane), LPG, Temperature Range : ‐20°C up to 60°C
Town Gas, Air, etc… • Pressure
• Pressure Class : PN1 Test Connection : 1/4” Threaded (Female)
• Connection or • Material Standard : Aluminum EN 1706,
Port Size : 1/2”, 3/4, 1”, 11/4”, 11/2”, 2” Rubbers EN 549
Threaded (Female) and DN65,
DN80, DN100 Flanged
CONFIGURATION
INLINE
INLINE
INLINE
INLINE
EGF 1080
5 EGF 1100
Convertion Constant
1 Methane : 1,28
LPG : 1,61
0.1
10 50 100 200 300 500 1000
Q (m3/hAir)
67
E G F
SERIES
DIMENSIONS
MODEL DN A B C D E F
MODEL DN A B C D E
68
E G F
SERIES
DIMENSIONS
69
w w w. e s k a v a l v e . c o m
EGF-H
SERIES
EGF-H
SERIES
• Usage : City gas networks and gas • Filter : Pore dimensions as standard
pipelines in industrial areas 50 micron (5-10-20 microns
• Fluid Type : Non‐corrosive gases such as on request)
Natural Gas (Methane), LPG, • Ambient
Temperature Range : ‐20°C up to 60°C
Town Gas, Air, etc…
• Pressure
• Pressure Class : PN6
Test Connection : 1/4” Threaded (Female)
• Connection or
• Material Standard : Aluminum EN 1706,
Port Size : 1/2”, 3/4, 1”, 11/4”, 11/2”, 2”
Threaded (Female) Rubbers EN 549
10
P (mbar)
Convertion Constant
5 Methane : 1,28
LPG : 1,61
0.1
*> 10 50 100 200 300 500 1000
Q (m3/hAir)
71
EGF-H
SERIES
CONFIGURATIONS
INLINE INLINE
DIMENSIONS
MODEL DN A B C D E
MODEL DN A B C D E
72
MECHANICAL
ACTUATED
SEISMIC VALVE SERIES
w w w. e s k a v a l v e . c o m
E M V
SERIES
E M V
SERIES
TECHNICAL INFORMATION
• Usage : City gas networks and gas • Maximum Working
pipelines in industrial areas Pressure : 0,5 bar
• Ambient
• Medium : Non‐corrosive gases such as
Temperature Range : ‐23°C up to 51,5°C
Natural Gas (Methane), LPG,
• Reset : Manually
Town Gas, Air, etc…
• Material Standard : Aluminum-EN 1706 /
• Montage Position : Vertical
Brass-EN12164 and
• Position : Normally Open
EN12165 / Rubber-EN549
• Connection or Port Size: 1”, 11/4”, 11/2”, 2” Threaded
(Female) DN65, DN80, DN100
Flanged
EMV 1025
EMV 1032 - 1040 - 1050
CONFIGURATION INLINE
INLINE
INLINE INLINE
100
DN 25-EMV 1025
10 DN 32-EMV 1032
DN 32-EMV 1032M
P (mbar)
5 DN 40-EMV 1040M
DN 40-EMV 1040
DN 50-EMV 1050
DN 65-EMV 1065
1
DN 80-EMV 1080
DN 100-EMV 1100
0.3
0.2
0.1
1 5 10 50 100 1000 10000
Q m3/hAir (Methane)
76
E M V
SERIES
DIMENSIONS
MODEL DN A B C D E F G
MODEL DN A B C D E F G
77
E M V
SERIES
DIMENSIONS
78
MANUAL RESET
VALVE SERIES
w w w. e s k a v a l v e . c o m
E G V
SERIES
E G V
SERIES
INTRODUCTORY
These are the manually adjusted gas valves used with the safety purposes in the gas lines to automatically stop the gas
flow by the effect of the signals given by the third party equipments such as gas alarm detectors, ventilation equipments
etc.
TECHNICAL INFORMATION
EGV 1100
EGV 1080
100
EGV 1065
50 EGV 1015
EGV 1020
EGV 1032
EGV 1025
10 EGV 1040
P (mbar)
5 EGV 1050
Convertion Constant
1
Methane : 1,28
LPG : 1,61
0,1
*= 10 50 100 200 300 500 1000
Q (m3/hAir)
82
E G V
SERIES
DIMENSIONS
MODEL DN A B C D E F
MODEL DN A B C D E F
83
E G V
SERIES
DIMENSIONS
84
w w w. e s k a v a l v e . c o m
E A C
SERIES
E A C
SERIES
The limit of the concentration level of the gases in the environment at which explosion or sparkling is called Lower Explo-
sion Limit (LEL).the LEL level of the natural gas is 5% and the LEL of the LPG is 2%; the gas alarm device starts audial and
lightened (visual) warning before the gas leak reaches one-fifth of this value. Visual and audible alarm is received between
the 3% LEL volume rate and 20% LEL volume rate of the gas.
The alarm adjustment level of the device for natural gas is %0,5 (five in a thousand) or 5.000 ppm (five thousand in a million) (5%).
The alarm adjustment level of the device for LPG is % 0,2 (two in a thousand) or 2.000 ppm (two thousand in a million) (5%).
The device can’t detect the gases with hazardous effects such as carbon monoxide.
The visual and audible alarms of the gas detection device works within 30 seconds at most after the device is exposed to the
gas volume it needs to detect..
The operation and feeding voltage of the product is 230VAC. The product can perform all its functions with 10% of the operation
voltage.
The device must be kept away from the rain and water.
DIMENSIONS
86
CABINET
S O L U T I O N S
S 3 0 0
CABINET
DIMENSIONS
210
3
2 4
T SE
1 5
528
0 6
bar
300
200 400
T SE
100 500
0 600
mbar
1122
574
535
LEGEND
4 7 8 9 10
3
1
0 6
5
2 S300 Cabinet Standard 1
bar
100 500
12
0 600
88
S2300
CABINET
DIMENSIONS
500
500
30 30
360 185 360 185
89
CES200
CABINET
DIMENSIONS
100
100
30
30
CES 203 3cm Lifting Platform CES 210 10cm Lifting Platform CES 203 3cm Lifting Platform CES 210 10cm Lifting Platform
50
50
CES 205 5cm Lifting Platform CES 205 5cm Lifting Platform
GAZ
GAZ
520
520
90
S 7 0 0
CABINET
DIMENSIONS
660
660
660
91
S2200
CABINET
DIMENSIONS
380
380
92
ESKA VALVE A.Ş.
Sakarya 1. Organize Sanayi Böl. T. +90 (264) 502 54 34-35 [email protected]
11. Cad. No: 6-8 Arifiye / Sakarya F. +90 (264) 502 54 84 www.eskavalve.com