DVP PLC _ Labeling Machine
Application
2011/03/29
Delta Confidential 1
Labeling Machine Application
Device Operation Structure
Label sensor
Product sensor
Driving axis
for labeling
Product
Product conveyer
Delta Confidential
Labeling Machine Application
Electronic Devices and PLC I/O
Main conveyer Driven by frequency inverter
Driving axis for labeling Driven by stepping drive and stepping motor
PLC Y0 output connected to Pulse input of stepping drive
PLC X0 input connected to Product sensor
PLC X4 output connected to Label sensor
Operation Steps
Step 1 Execute the inverter to move the conveyer for feeding products.
Step 2 Wait for next step until the product sensor X0 is triggered.
Step 3 Y0 outputs to stepping drive and stamps the label on the product.
Step 4 Wait for the triggering of label sensor. When triggered, output specified
number of pulses and stop. Go back to step 2.
Delta Confidential
Labeling Machine Application
Program Example
Enable external interrupt
Set start frequency
Set ramp-up time
Enable ramp-down time setting
Set ramp-down time
Set pulse number for ramp-down
stop when Mark sensor is ON.
Set total output pulses
Set target speed
Enable Mark function on Y0
Auto reset Y0 when output is
completed
Enable Y0 output
When Y0 Mark function is activated,
count the labeling times by D0
Delta Confidential
Labeling Machine Application
Key Techniques:
Conveyer speed affects the target labeling speed. Improper setting will cause
bad stamping quality.
Start frequency and ramp-up time setting of stepping drive affects the label position
on product, e.g. when ramp-up time is 10ms, start freq. should be ≧ 2kHz
otherwise the ramp-up time can not be achieved.
Interval between product sensor ON and PLC output should be accurate and fixed.
Interval between label sensor ON and ramp-down stop should be accurate.
PLC should support ramp-down stop pulses setting. The pulse number will affect
the start position of next label.
PLC Models for This Function
ES2/EX2 V1.5 or above. For V1.5 below, DDRVI should be placed in main program
SX2 V1.1 or above. For V1.1 below, DDRVI should be placed in main program.
SA2 V0.8 or above.
Delta Confidential
EH2/SV V1.8 or above.
Thank You
Delta Confidential