MEMBER OF 1495
RATING GPM__________FT. HD. __________RPM________CERTIFIED TEST BY____________
&
DF 10" x 10"
PUMP TYPE______SIZE________IMPELLER C-0110
DIA_______PATTERN NO.____________________
7:50 AM
NFPA
BR. H.P.
PERFORMANCE CURVES ARE BASED ON: 1) CLEAR WATER WITH A SPECIFIC GRAVITY OF 1.0
FM
N.P.S.H.FT.
HEADFT.
UL
LISTED APPROVED 2) PROPER N.P.S.H. CONDITIONS
200
15"
16
60%
70%
150 80%
80%
85% 70%
100
85%
80%
70%
200 50
Dia. 18 3/8"
N.P.S.H.R.
15"
0 0
0 1000 2000 3000 4000 5000 6000
GPM
8902RBull504
&
DF 10" x 10"
PUMP TYPE______SIZE________IMPELLER C-0110
DIA_______PATTERN NO.____________________
NFPA
BR. H.P.
PERFORMANCE CURVES ARE BASED ON: 1) CLEAR WATER WITH A SPECIFIC GRAVITY OF 1.0
FM
N.P.S.H.FT.
HEADFT.
UL
2) PROPER N.P.S.H. CONDITIONS
7:50 AM
LISTED APPROVED
UL/FM APPROVAL
FLOW PR. RANGE
(GPM) (PSI)
Page 17
1500 60-158
2000 55-154
2500 55-150
3000 65-142
3500 97-112
400
Dia. 18 3/8" 60% 70%
80%
17
300
16"
80%
14" 70%
200
85%
12"
500 100
60% 70%
Dia. 16 1/2" 80%
80%
70% N.P.S.H.R.
0 0 12"
0 1000 2000 3000 4000 5000 6000
GPM
8902RBull504
MEMBER OF 2100
RATING GPM__________FT. HD. __________RPM________CERTIFIED TEST BY____________
&
DF 10" x 10"
PUMP TYPE______SIZE________IMPELLER C-0110
DIA_______PATTERN NO.____________________
NFPA
7:50 AM
BR. H.P.
PERFORMANCE CURVES ARE BASED ON: 1) CLEAR WATER WITH A SPECIFIC GRAVITY OF 1.0
FM
N.P.S.H.FT.
HEADFT.
UL
LISTED APPROVED 2) PROPER N.P.S.H. CONDITIONS
UL/FM APPROVAL
Page 18
18
15"
300 85%
13 1/2"
90%
80%
12"
200
60%
70%
80%
500 100
0 0 12" N.P.S.H.R.
0 1000 2000 3000 4000 5000 6000 7000
GPM
8902RBull504
MEMBER OF 2300
RATING GPM__________FT. HD. __________RPM________CERTIFIED TEST BY____________
&
DF 10" x 10"
PUMP TYPE______SIZE________IMPELLER C-0110
DIA_______PATTERN NO.____________________
NFPA
BR. H.P.
PERFORMANCE CURVES ARE BASED ON: 1) CLEAR WATER WITH A SPECIFIC GRAVITY OF 1.0
FM
N.P.S.H.FT.
HEADFT.
UL
7:50 AM
(GPM) (PSI)
Dia. 16 1/2" 50% 60%
70% 1500 100-218
500 80% 2000 100-216
2500 100-210
85% 3000 95-203
15" 3500 113-197
400
85%
19
13 1/2" 90%
80%
300
12"
80%
500 100
Dia. 16 1/2"
12" N.P.S.H.R.
0 0
0 1000 2000 3000 4000 5000 6000 7000
GPM
8902RBull504
MEMBER OF 3580
RATING GPM__________FT. HD. __________RPM________CERTIFIED TEST BY____________
&
DF 10" x 10"
PUMP TYPE______SIZE________IMPELLER C-0110
DIA_______PATTERN NO.____________________
7:50 AM
NFPA
BR. H.P.
PERFORMANCE CURVES ARE BASED ON: 1) CLEAR WATER WITH A SPECIFIC GRAVITY OF 1.0
FM
N.P.S.H.FT.
HEADFT.
UL
LISTED APPROVED 2) PROPER N.P.S.H. CONDITIONS
600 50% UL/FM APPROVAL
Page 20
10 1/2"
400
20
50%
60%
300
80%
70%
1000 200
Dia. 12"
500 100
10 1/2"
N.P.S.H.R.
0 0
0 1000 2000 3000 4000 5000 6000
GPM
8902RBull504
BR. H.P.
PERFORMANCE CURVES ARE BASED ON: 1) CLEAR WATER WITH A SPECIFIC GRAVITY OF 1.0
FM
N.P.S.H.FT.
HEADFT.
UL
7:50 AM
1500 46-130
500 2000 42-125
400
21
60% 70%
Dia. 17 1/8"
300 80%
85%
15"
85%
200 13"
80%
70%
11 1/4"
500 100
60%
70%
MEMBER OF 2950
RATING GPM__________FT. HD. __________RPM________CERTIFIED TEST BY____________
&
DF 10" x 10"
PUMP TYPE______SIZE________IMPELLER C-0146
DIA_______PATTERN NO.____________________
7:50 AM
NFPA
BR. H.P.
PERFORMANCE CURVES ARE BASED ON: 1) CLEAR WATER WITH A SPECIFIC GRAVITY OF 1.0
FM
N.P.S.H.FT.
HEADFT.
UL
LISTED APPROVED 2) PROPER N.P.S.H. CONDITIONS
Dia. 15"
600 60% UL/FM APPROVAL
Page 22
12"
400
85%
22
80%
60%
300 70%
70%
200
70%
500 100
Dia. 15"
12"