PRISM JOHNSON LIMITED
(FORMERLY PRISM CEMENT LIMITED)
RMC India Division
Concrete Mix Proportion - M 30Easycrete
As Per IS 10262 : 2019
Agency :- Shriram Grand City
Site :- Uttarpara
1. Design Stipulation.
a) Grade of Concrete M30Easycrete
b) Type of Cement Ramco OPC 53
c) Type of Fly ash Majia Power Plant - class F
d) Maximum Nominal size of aggregates 10 mm
e) Workability( FLOW) 600x600 mm for Easycrete
f) Method of concrete placing Pumping
Super Plastisizer as per IS 9103
g) Chemical admixture type
(MYK Armix Hyyecrete PC30)
2. Material properties
a) Cement used OPC 53 Grade
b) Specific gravity of cement Source :-Bishnupuram,Telengana 3.13
b) Specific gravity of fly ash Source :-Majia 2.12
c) Specific gravity of coarse aggregate(10 mm) Source :-Rampurhat 2.83
d) Specific gravity of fine aggregate Source :-Bankura 2.62
e) Specific gravity of superplasticizer Source :- BASF,Khargpur 1.10
f) water absorption of Coarse aggregate(10 mm) 0.97 %
g) water absorption of Fine aggregate 1.22 %
h) Sieve analysis of Fine aggregate Conforming to zone II as per IS 383
Target strength for Mix Proportioning = Fck'=Fck+1.65s
Fck'= Target average Compressive Strength at 28 days
fck= Characteristics Compressive Strength at 28 days 30 N/mm 2
s =Standerd Deviation as per IS 456 5
Hence target strength= 30+1.65x5= 38.25 N/mm 2
Page 1
3.Selection of Water-Cement Ratio 0.335
4.Selection of Water Content
Estimated water content for 600x600 mm Flow for Easycrete Concrete = 190.95 kg
5.Calculation of cement
Water cement ratio adopted for mix = 0.335
Cementious content = water /(w/c) = 570 kg
Assumed Cementious content = 570 kg
Cement Content 380 kg
Fly Ash Content 190 kg
Water content = 190.95 kg
6.Mix calculations
a. Volume of concrete (Air :- 1.00%) 0.99 cum
b. Volume of cement (mass of cement / sp.gr. Of cement*1/1000) 0.1214 cum
c. Volume of fly ash (mass of fly ash / sp.gr. Of Fly Ash*1/1000) 0.0896 cum
d. Volume of water (Water content/1000) 0.1910 cum
Dose of water reducing admixture by weight of cementious material in % = 0.60 %
Mass of admixture 570kg x 0.60% 3.42 Kg
mass of admixture / sp.gravity of
e. Volume of super plastisizer 0.0031 Cum
admixture*1/1000
f. Volume of All in aggregates {1- (b+c+d+e)} 0.5849 Cum
Proportion of course aggregate & fine aggregate 49.5:50.5
g. Volume of 10 mm aggregate (0.5849 x 49.5 / 100) 0.2895 Cum
h. Volume of fine aggregates (0.5849 x 50.5 / 100) 0.2954 Cum
Mass of coarse aggregate(10 mm) (0.2895*2.83*1000) 819 Kg
Mass of fine aggregate (0.2954*2.62*1000) 774 Kg
7.Mix Proportion for Trial Mix for one cum of concrete(SSD)
Cement 380 kg
Fly Ash 190 kg
Water 190.95 kg
Fine aggregate 774 kg
10mm C A 819 kg
Chemical Admixture 3.420 kg
Fresh Density 2358 Kg/Cum
Page 2
Mix Proportion for Trial Mix for one cum of concrete(DRY)
Cement 380 kg
Fly Ash 190 kg
[190.95+(819 x 0.97 / 100 + 774
Water 208 kg
x 1.22 / 100)]
Fine aggregate [774 - (774 x 1.22 / 100)] 765 kg
10mm C A [819 - (819 x 0.97 / 100)] 811 kg
Chemical Admixture 3.420 kg
Fresh Density 2358 Kg/Cum
Comment1: The Report is based on the properties of samples received by us , RMC reserves right to make
necessary changes in source/quantity to suit the properties of samples in future.
Comment2 :The Admixture doses will vary inaccordance to atmospheric condition with respect to the
approve doses.
S.N.Chatterjee
Dy.Manager(QC)