0% found this document useful (0 votes)
513 views3 pages

M30 Concrete Mix Design Specifications

The document provides a concrete mix proportion for M30 grade concrete. It specifies the materials used including cement, fly ash, aggregates, and admixtures. It details the material properties, mix design calculations, target strength, water-cement ratio, and the final mix proportions for 1 cubic meter of concrete in both saturated surface dry and dry conditions. The mix meets the stipulated design strength and workability requirements for pumping and placing the concrete.

Uploaded by

abir sengupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
513 views3 pages

M30 Concrete Mix Design Specifications

The document provides a concrete mix proportion for M30 grade concrete. It specifies the materials used including cement, fly ash, aggregates, and admixtures. It details the material properties, mix design calculations, target strength, water-cement ratio, and the final mix proportions for 1 cubic meter of concrete in both saturated surface dry and dry conditions. The mix meets the stipulated design strength and workability requirements for pumping and placing the concrete.

Uploaded by

abir sengupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

PRISM JOHNSON LIMITED

(FORMERLY PRISM CEMENT LIMITED)


RMC India Division
Concrete Mix Proportion - M 30Easycrete
As Per IS 10262 : 2019

Agency :- Shriram Grand City

Site :- Uttarpara

1. Design Stipulation.
a) Grade of Concrete M30Easycrete

b) Type of Cement Ramco OPC 53

c) Type of Fly ash Majia Power Plant - class F

d) Maximum Nominal size of aggregates 10 mm

e) Workability( FLOW) 600x600 mm for Easycrete

f) Method of concrete placing Pumping


Super Plastisizer as per IS 9103
g) Chemical admixture type
(MYK Armix Hyyecrete PC30)

2. Material properties
a) Cement used OPC 53 Grade

b) Specific gravity of cement Source :-Bishnupuram,Telengana 3.13

b) Specific gravity of fly ash Source :-Majia 2.12

c) Specific gravity of coarse aggregate(10 mm) Source :-Rampurhat 2.83

d) Specific gravity of fine aggregate Source :-Bankura 2.62

e) Specific gravity of superplasticizer Source :- BASF,Khargpur 1.10

f) water absorption of Coarse aggregate(10 mm) 0.97 %

g) water absorption of Fine aggregate 1.22 %

h) Sieve analysis of Fine aggregate Conforming to zone II as per IS 383

Target strength for Mix Proportioning = Fck'=Fck+1.65s

Fck'= Target average Compressive Strength at 28 days

fck= Characteristics Compressive Strength at 28 days 30 N/mm 2

s =Standerd Deviation as per IS 456 5

Hence target strength= 30+1.65x5= 38.25 N/mm 2

Page 1
3.Selection of Water-Cement Ratio 0.335

4.Selection of Water Content


Estimated water content for 600x600 mm Flow for Easycrete Concrete = 190.95 kg

5.Calculation of cement
Water cement ratio adopted for mix = 0.335

Cementious content = water /(w/c) = 570 kg

Assumed Cementious content = 570 kg

Cement Content 380 kg

Fly Ash Content 190 kg

Water content = 190.95 kg

6.Mix calculations
a. Volume of concrete (Air :- 1.00%) 0.99 cum

b. Volume of cement (mass of cement / sp.gr. Of cement*1/1000) 0.1214 cum

c. Volume of fly ash (mass of fly ash / sp.gr. Of Fly Ash*1/1000) 0.0896 cum

d. Volume of water (Water content/1000) 0.1910 cum

Dose of water reducing admixture by weight of cementious material in % = 0.60 %

Mass of admixture 570kg x 0.60% 3.42 Kg


mass of admixture / sp.gravity of
e. Volume of super plastisizer 0.0031 Cum
admixture*1/1000
f. Volume of All in aggregates {1- (b+c+d+e)} 0.5849 Cum

Proportion of course aggregate & fine aggregate 49.5:50.5

g. Volume of 10 mm aggregate (0.5849 x 49.5 / 100) 0.2895 Cum

h. Volume of fine aggregates (0.5849 x 50.5 / 100) 0.2954 Cum

Mass of coarse aggregate(10 mm) (0.2895*2.83*1000) 819 Kg

Mass of fine aggregate (0.2954*2.62*1000) 774 Kg

7.Mix Proportion for Trial Mix for one cum of concrete(SSD)


Cement 380 kg

Fly Ash 190 kg

Water 190.95 kg

Fine aggregate 774 kg

10mm C A 819 kg

Chemical Admixture 3.420 kg

Fresh Density 2358 Kg/Cum

Page 2
Mix Proportion for Trial Mix for one cum of concrete(DRY)
Cement 380 kg

Fly Ash 190 kg


[190.95+(819 x 0.97 / 100 + 774
Water 208 kg
x 1.22 / 100)]
Fine aggregate [774 - (774 x 1.22 / 100)] 765 kg

10mm C A [819 - (819 x 0.97 / 100)] 811 kg

Chemical Admixture 3.420 kg

Fresh Density 2358 Kg/Cum

Comment1: The Report is based on the properties of samples received by us , RMC reserves right to make

necessary changes in source/quantity to suit the properties of samples in future.


Comment2 :The Admixture doses will vary inaccordance to atmospheric condition with respect to the

approve doses.

S.N.Chatterjee
Dy.Manager(QC)

Page 3

You might also like