INSTRUCTION MANUAL

SETTING AND ADJUSTMENTS

Model FMD-3200/FMD-3200-BB/FMD-3300/FCR-2119-BB/
FCR-2129-BB/FCR-2139S-BB/FCR-2819/FCR-2829
FCR-2839S/FCR-2829W/FCR-2839SW

This manual is solely for use by the installer. Under no


circumstances shall this manual be released to the user.

The installer shall remove this manual from the vessel


after installation.

This manual contains no password data. Obtain password


data from FURUNO before beginning the installation.

www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
www.furuno.com

Pub. No. E42-01204-N1


(1910, YOSH ) FMD-3xxx/FCR-2xx9
Printed in Japan
䢲䢲䢲䢳䢻䢶䢺䢷䢺䢳䢴
INTRODUCTION
About this manual
This manual shows how to setup ECDIS and Chart Radar after the installation.

After setting, make a backup copy of configuration data onto a medium (PC, etc.).

Preparation
• PC (for the LAN connection)
• LAN cable (for the LAN connection)

Trademarks
Windows and Internet Explorer are either registered trademarks or trademarks of Microsoft Cor-
poration in the United States and/or other countries.

Silent mode
Use the silent mode when the ECDIS is not required, like in a harbor. This mode deactivates the
audio alarms.

1. Click the [OTHERS] button on the Status bar in the chart mode then click [SILENT].
You are prompted for a password.

2. Enter "3000", then click the [OK] button.


The following pop-up window appears.

Click to return to normal operation.


3. To return to normal operation, click the [Back to Normal Mode] button in the pop-up window
shown above.

i
TABLE OF CONTENTS
1. INITIAL SETTING AND ADJUSTMENT ................................................................1-1
1.1 How to Access the [Common Installation Setting] Menu ........................................... 1-1
1.1.1 Laptop PC (LAN connection) access ............................................................. 1-1
1.1.2 Control Unit RCU-024/025/026 ...................................................................... 1-2
1.1.3 [Common Installation Setting] menu contents................................................ 1-3
1.2 [Basic Setting] Menu .................................................................................................. 1-4
1.2.1 [Basic Setting] window ................................................................................... 1-4
1.2.2 [Peripherals] window ...................................................................................... 1-6
1.2.3 [VDR] window................................................................................................. 1-9
1.2.4 [Route Transfer] window .............................................................................. 1-10
1.2.5 [Application] window..................................................................................... 1-10
1.2.6 [Ship Name] window .................................................................................... 1-11
1.2.7 [ECDIS/Radar] window ................................................................................ 1-11
1.2.8 [Language] window ...................................................................................... 1-12
1.3 [Own Ship Setting] Menu ......................................................................................... 1-13
1.4 [Installation Parameters] Menu ................................................................................ 1-15
1.4.1 Sensor setting .............................................................................................. 1-15
1.4.2 Processor unit configuration......................................................................... 1-17
1.4.3 Activating the connection with the processor unit of the FAR-2uu8 series
radar (ECDIS only)....................................................................................... 1-24
1.4.4 Sensor Adapter configuration....................................................................... 1-26
1.4.5 Antenna unit configuration ........................................................................... 1-30
1.4.6 Radar connection box configuration (ECDIS only)....................................... 1-31
1.4.7 Monitoring of HUB........................................................................................ 1-32
1.4.8 Signal and Port setting for external equipment ............................................ 1-33
1.4.9 Customized sensor setting........................................................................... 1-35
1.4.10 Settings to activate the shuttle ferry mode (Chart Radar only) .................... 1-36
1.5 [CCRS] Menu ........................................................................................................... 1-37
1.5.1 How to select the [Data Source]................................................................... 1-37
1.5.2 How to set [Transmission Group]................................................................. 1-38
1.5.3 [CCRS Setting] window................................................................................ 1-40
1.6 [TCS] Menu .............................................................................................................. 1-41
1.6.1 Preparation................................................................................................... 1-41
1.6.2 How to set the TCS for autopilot .................................................................. 1-43
1.6.3 How to set the Navigation Parameter .......................................................... 1-45
1.6.4 Multiple ECDIS and autopilot control ........................................................... 1-50
1.6.5 Detail settings for the TCS ........................................................................... 1-51
1.6.6 [Filter Setting] window .................................................................................. 1-53
1.6.7 [Other Setting] window ................................................................................. 1-53
1.7 [AMS] Menu ............................................................................................................. 1-54
1.7.1 AMS mode operation ................................................................................... 1-54
1.7.2 Master/Backup AMS setting......................................................................... 1-55
1.7.3 Alert transfer setting ..................................................................................... 1-56
1.7.4 Other setting window.................................................................................... 1-58
1.7.5 How to import and export [AMS] menu settings........................................... 1-59
1.8 [Alert Define List] Menu............................................................................................ 1-60
1.8.1 Alert Group Setting....................................................................................... 1-60
1.8.2 How to add an alert group............................................................................ 1-62
1.8.3 How to edit an alert group ............................................................................ 1-63
1.8.4 How to delete an alert group ........................................................................ 1-63
1.8.5 Alert Definition setting for each equipment .................................................. 1-63
1.8.6 How to add an alert definition....................................................................... 1-65

ii
TABLE OF CONTENTS

1.8.7 How to edit an alert definition .......................................................................1-67


1.8.8 How to delete an alert definition ...................................................................1-67
1.9 [Data Sharing] Menu.................................................................................................1-67
1.10 [Save and Sync] Menu .............................................................................................1-68
1.10.1 Consistency check and save the configuration ............................................1-68
1.10.2 How to save the configuration data to a medium .........................................1-70
1.10.3 How to load the configuration data ..............................................................1-70
1.11 [System Monitor] Menu.............................................................................................1-71
1.12 [Software Update] Menu...........................................................................................1-72
1.13 [Factory Test & Default] Menu..................................................................................1-73
1.14 [Conning] Menu ........................................................................................................1-74
1.14.1 How to select the data source ......................................................................1-76
1.14.2 Advanced settings window ...........................................................................1-77
1.15 Network Transmission Setting Between ECDIS and Radar .....................................1-98
1.16 How to Set the Forwarding Distance ......................................................................1-101
1.17 Synchronization With Ship’s Clock .........................................................................1-102
1.18 How to Change the Color of Data in the Sensor Information Box According to
Integrity...................................................................................................................1-102

2. SETTING FOR SENSOR ADAPTER.....................................................................2-1


2.1 How to Set the Equipment ID .....................................................................................2-1
2.2 How to Save the Log File ...........................................................................................2-2
2.3 How to Update the Firmware (MC-3000S) .................................................................2-2
2.3.1 How to activate the maintenance program .....................................................2-3
2.3.2 How to confirm the firmware program version................................................2-3
2.3.3 How to update the firmware program .............................................................2-4

3. DUAL GYRO SYSTEM (ECDIS Only)...................................................................3-1

4. HUB-3000 IGMP QUERIER SETTING ..................................................................4-1

5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400.................................................5-1


5.1 Installation Parameters...............................................................................................5-1
5.1.1 HCS setting ....................................................................................................5-1
5.1.2 NP-5400 alert and backup navigator setting ..................................................5-2
5.1.3 BNWAS setting...............................................................................................5-2
5.1.4 Serial ports configuration................................................................................5-3
5.2 TCS Port Setting.........................................................................................................5-4
5.3 NP-5400 Alert Port Setting .........................................................................................5-5
5.4 NP-5400 Backup Navigator Port Setting ....................................................................5-5
5.5 Position and Time Ports Settings ...............................................................................5-5
5.6 Speed Port Setting .....................................................................................................5-6
5.7 Backup Navigator Setting ...........................................................................................5-6
5.8 Save and Sync ...........................................................................................................5-6

APPENDIX 1 EQUIPMENT ID List ...........................................................................AP-1


APPENDIX 2 SUBSYSTEM ......................................................................................AP-3
APPENDIX 3 RCB-002 IP ADDRESS SETTING......................................................AP-4

iii
TABLE OF CONTENTS

This page is intentionally left blank.

iv
1. INITIAL SETTING AND
ADJUSTMENT
This chapter shows you how to enter the initial settings for the processor unit (EC-
3000) of ECDIS and Chart Radar after the installation.

Note: Each unit has a default IP address. Enter the initial settings (Equipment ID set-
ting) and change the IP address on the [Basic Setting] menu (see section 1.2.), before
connecting each unit and building the network. After entering the equipment ID(s),
build the network and enter other settings. You can enter the settings of each unit all
at one time by building the network.

1.1 How to Access the [Common Installation


Setting] Menu
The initial settings for the ECDIS and Chart Radar are performed on the [Common In-
stallation Setting] menu. The [Common Installation Setting] menu works with a web
browser.

Access the [Common Installation Setting] menu by either of the two methods shown
below.

• Access on a laptop PC (LAN connection). See section 1.1.1.


• Access with the control unit RCU-024/025/026. See section 1.1.2.
Note 1: Supported browsers are as follows:
• Internet Explorer® 11
• Firefox ESR 60

Note 2: To update the software with the updating file (see section 1.12.), access the
[Common Installation Setting] menu via LAN connection. To update the software with
the DVD, access the [Common Installation Setting] menu with the control unit.

Note 3: When you access the MC-3000S directly from Internet Explorer®, you cannot
adjust the settings on the [Alert Define List] menu. Access either the EC-3000, or use
Firefox to adjust the settings on the [Alert Define List] menu.

1.1.1 Laptop PC (LAN connection) access


1. Set the IP address and subnet mask of the PC according to the LAN port where
the PC is connected.
Note: For the Sensor Adapter, use the LAN2 port (sensor network).
IP address/
LAN port Setting value
Subnet mask
LAN1 IP address 192.168.31.200
(Gateway network) Subnet mask 255.255.255.0
LAN2 IP address 172.31.16.200
(Sensor network) Subnet mask 255.255.0.0

1-1
1. INITIAL SETTING AND ADJUSTMENT

2. Connect the PC to the LAN1 or LAN2 port of the processor unit with a LAN cable.
Note: It is possible to connect to the LAN1 or LAN2 port via a LAN hub. However,
to operate from the [Basic Setting] menu, turn off all units except the unit to be set.
Enter settings to processor units one by one.
3. Activate the web browser on the PC.
4. Enter the IP address on the address bar on the browser referring to the following
table.
Access
Type IP address
point
For the initial setting Gateway ECDIS 192.168.31.1
Network Chart Radar 192.168.31.31
Sensor ECDIS 172.31.16.1
Network Chart Radar 172.31.16.21
For re-setting the unit Gateway ECDIS Enter the IP address of the gateway
Network Chart Radar or sensor network according to the
Equipment ID used in the system.
See the Equipment ID list at the back
of this manual.

When entering the IP address on the address bar, you are asked to enter ID and
password.

5. Enter the ID and password correctly then click the [Login] button.
The [Common Installation Setting] menu appears.

1.1.2 Control Unit RCU-024/025/026

1. Click [ ] on the status bar then select [Settings]. The pop-up message shown
below appears.

2. Click [OK] to show the [Settings] menu.


3. Click [SERVICE MODE] on the status bar, and then select [Service Login].
The password input dialog box appears.

1-2
1. INITIAL SETTING AND ADJUSTMENT

4. Enter the password and click [OK]. [Service Mode] is shown at the bottom left po-
sition of the [Settings] window.
For RCU-024: Use the keyboard on the control unit to enter the password.
For RCU-025/026: Use the software keyboard on the display to enter the pass-
word.
5. Click [SERVICE MODE] on the status bar, and then select [Common Installation
Setting]. The message shown below appears.

6. Click [OK] to activate the web browser and show the dialog box asking for ID and
password.

7. Enter the ID and password correctly then click the [Login] button.
The [Common Installation Setting] menu appears.

1.1.3 [Common Installation Setting] menu contents


Note: Click [Exit] to close and logout from the [Common Installation Setting] menu.
You can close and logout by clicking on the web browser. However the menu can
not be re-accessed for a while.

Click here to close and


Tab bar
logout from the
[Common Installation
Setting] menu.

Menu bar* View area

Info bar
*: Selected item is highlighted in blue.

The selected tab is highlighted in blue on the tab bar. The view area and menu bar
change according to the tab selected.

Click [ (or )] at the tab bar to shift the tab to the left (or right).

Note: If the tab bar does not move when clicking either or , clear the browser
cache.

1-3
1. INITIAL SETTING AND ADJUSTMENT

Basic Setting Own Ship Setting Installation Parameters CCRS TCS AMS

Click .. Click ..

Own Ship Setting Installation Parameters CCRS TCS AMS Alert Define List

Tab name Feature


Basic Setting Sets the Equipment ID, monitor unit, printer, and own ship
information, etc.
Own Ship Setting Enters the ship’s parameter and sensor position.
Installation Parameters Sets the system configuration and input/output data.
CCRS Sets the priority of the sensors and NMEA sentences.
TCS Sets the TCS.
AMS Sets the AMS and relevant settings.
Alert Define List Sets the alerts.
Data Sharing* Sets the interlocking system between units.
Save and Sync Save and synchronize the settings. You can save settings to
a medium.
System Monitor Confirms the system condition.
Software Update Updates the software.
Factory Test and Default Performs the factory test; restores the default settings.
Conning Configures the layout and data to show on the conning dis-
play.

*: Adjustment not required.

1.2 [Basic Setting] Menu

1.2.1 [Basic Setting] window


1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.

2. Select the Equipment ID of the processor unit from the [Equipment ID] pull-down
list.
For the ECDIS: Setting range: [ECD001] to [ECD016]

1-4
1. INITIAL SETTING AND ADJUSTMENT

For the Chart Radar: Setting range: [CRA001] to [CRA004]. Do not select
[CRA005] to [CRA010].
The [Equipment Name], [Equipment Type No.], and [IP Address] are automatically
entered according to the Equipment ID. For details, see the Equipment ID list is at
the back of this manual.
Note 1: For the first ECDIS, set [Equipment ID] to [ECD001]. For the first Chart
Radar, set [Equipment ID] to [CRA001].
Note 2: Assign a different Equipment ID to each processor unit.
Note 3: [Serial No.] is entered before shipment. If you change the SSD or delete
[Serial No.] by mistake, click the box of [Serial No.] to enter the serial number of
the processor unit (example: xxxx-xxxx).
Note 4: The properties of data transmitted under IEC61162-450 protocol are
changed according to the Equipment ID settings.
• The Processor Unit's SFID, Device No. and Channel change as shown in the
following table.
Equipment ID SFID Device No. Channel
CRA001 RA0001 61 1, 2, 3
CRA002 RA0002 62 1, 2, 3
CRA003 RA0003 63 1, 2, 3
CRA004 RA0004 64 1, 2, 3
ECD001 EI0001 21 1, 2, 3
ECD002 EI0002 22 1, 2, 3
ECD003 EI0003 23 1, 2, 3
ECD004 EI0004 24 1, 2, 3
ECD005 EI0005 25 1, 2, 3
ECD006 EI0006 26 1, 2, 3
ECD007 EI0007 27 1, 2, 3
ECD008 EI0008 28 1, 2, 3
ECD009 EI0009 29 1, 2, 3
ECD010 EI0010 30 1, 2, 3
ECD011 EI0011 31 1, 2, 3
ECD012 EI0012 32 1, 2, 3
ECD013 EI0013 33 1, 2, 3
ECD014 EI0014 34 1, 2, 3
ECD015 EI0015 35 1, 2, 3
ECD016 EI0016 36 1, 2, 3

• When this unit has Back-up ECDIS enabled (see subsection 1.4.2) and Back-
up ECDIS mode is active, the SFID changes as shown below.
Back-up ECDIS Back-up ECDIS
is not active is active*
RA0001 EI0021
RA0002 EI0022
RA0003 EI0023
RA0004 EI0024

*: This SFID is applied to all ECDIS-related functions.

3. Select [FMD-3200|3300] or [FCR-2uu9] from the [Equipment Type No.] pull-down


list.
Note: Do not use [FCR-2uu9 ED.1] and [FCR-2uu9 ED.2].

1-5
1. INITIAL SETTING AND ADJUSTMENT

4. For the Chart Radar, select the Equipment ID of the radar processor unit from
the [Equipment ID] pull-down list. Setting range: [RAS001] to [RAS004]. Do not
use [RAS005] to [RAS010]. For the ECDIS, go to step 8.
The [Equipment Name], [Equipment Type No.], and [IP Address] are automatically
entered according to the Equipment ID.
5. Select [RPU-013] from the [Equipment Type No.] pull-down list.
6. Select the antenna position from the [Antenna Position] pull-down list.
Settings: [Fore], [Main Top], [Main 2nd], [Main 3rd], [Aft], [Port], [Starboard].
7. Click the box of [Serial No.] to enter the serial number of the radar processor unit
(example: xxxx-xxxx).
8. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].

1.2.2 [Peripherals] window


1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
2. Click [Peripherals] on the menu bar.

*3

*1

*2

*1䠖Not used.
*2䠖Shown for the ECDIS.
*3䠖Shown when [Connected] is selected in [Connection] of [Service Gateway].
3. Select the monitor type and resolution connected to the DVI1 port from the [Type
Number] pull-down list of DVI1.
The setting options are as follows:
• [MU-190 (SXGA)] • [HD 24T22FUD (FHD)]*4
• [MU-231 (SXGA)] • [HD 24T22FUD (WUXGA)]
• [MU-231 (UXGA)] • [HD 26T21MMD (WUXGA)]
• [MU-270W (WUXGA)]*1 • [HD 26T22MMD (WUXGA)]*2
• [MU-270W-B (WUXGA)]*1 • [HD 26T22FUD (WUXGA)]
• [MU-270W-C (WUXGA)]*1 • [HD 27T22FUD (FHD)]*4
• [MU-201CE (SXGA)] • [HD 27T22FUD (WUXGA)]
• [MU-231CE (SXGA)] • [HD 32T22FUD (FHD)]*4
• [MU-231CE (UXGA)]*3 • [HD 32T22FUD (WUXGA)]

1-6
1. INITIAL SETTING AND ADJUSTMENT

• [JH 19T14FUD (SXGA)] • [HD 55T22FUD (FHD)]*4


• [JH 20T17FUD (UXGA)] • [HD 55T22FUD (WUXGA)]
• [JH 23T12FUD (UXGA)]*2 • [NI WA460-01.MON.01(FHD)]*4
• [JH 23T14FUD (UXGA)] • [NI WA460-01.MON.01(WUXGA)]
• [JH 26T11MMD (WUXGA)]*2 • [NI WA270-01.MON.01-XXFU(FHD)]*4
• [HD 19T21MMD (SXGA)]*2 • [NI WA270-01.MON.01-XXFU(WUXGA)]
• [HD 24T21MMD (FHD)]*2, 4
* • [AHD 119F (SXGA)]*3
• [HD 24T21MMD (WUXGA)]*2 • [AHD 119G (SXGA)]*3
*1: Depending the MU-270W serial number, select one of the following:
- Serial numbers “1000-4610-xxxx” or “10xxxx”: [MU-270W (WUXGA)]
- Serial number “1000-4611-xxxx”: [MU-270W-B (WUXGA)]
- Serial number “1000-4612-xxxx”: [MU-270W-C (WUXGA)]
*2: Do not use for the monitor connected to the DVI1 port. These monitors are avail-
able for the port other than DVI1 port.
*3: Not used.
*4: ECDIS only.

Note 1: The DVI2 port outputs the display data same as the data of DVI1 port.
Note 2: If the MU-201, MU-231CE or the monitor of Hatteland Display is connect-
ed, the optional cable DSUB9P-X2-A-L5M/L10M for brilliance control is required
to connect.
4. Select the monitor type and resolution connected to the DVI3 port from the [Type
Number] pull-down list of DVI3.
When the processor unit is not connected to the VDR or you do not use the dual
display, select [Not Connected (NONE)] and go to the step 8.
5. Select the display data to output from the DVI3 port from the [Output Mode] pull-
down list.
Setting option Remarks
[Clone] DVI1 to DVI3 ports output the same resolution and display data. For the
ECDIS, the DVI1 port can switch ECDIS and Conning display data.
Note 1: When [Clone] is selected, the [Type Number] for DVI1 and
DVI3 port should be same setting option.
Note 2: When the Chart Radar is connected to a VDR, it is required to
set to [Clone].
[Independent] The DVI3 port outputs the conning display data.
Note: Do not set to [Independent] in case of the Chart Radar, when the
CPU board of the EC-3000 is “ADP-555-xx”.

6. When one of the following monitors is selected at step 3, click the [Run] button for
[Monitor Color Calibration] to perform the color calibration. For all other monitors,
go to step 8.
• [HD 19T21MMD (SXGA)] • [HD 26T22FUD (WUXGA)]
• [HD 24T21MMD (FHD)] • [HD 27T22FUD (FHD)]
• [HD 24T21MMD (WUXGA)] • [HD 27T22FUD (WUXGA)]
• [HD 24T22FUD (FHD)] • [HD 32T22FUD (FHD)]
• [HD 24T22FUD (WUXGA)] • [HD 32T22FUD (WUXGA)]
• [HD 26T21MMD (WUXGA)] • [HD 55T22FUD (FHD)]
• [HD 26T22MMD (WUXGA)] • [HD 55T22FUD (WUXGA)]

1-7
1. INITIAL SETTING AND ADJUSTMENT

“Processing” appears at the next to the [Run] button during the color calibration.
After completing the calibration, check result appears ([Succeeded] or [Failed]).
When the check result is [Succeeded], the following confirmation message ap-
pears. Click the [OK] button to reboot the system and apply the calibration setting.
When the check result is [Failed], retry the color calibration. If the error is not rec-
tified, contact your dealer.

Note: Be sure to perform the color calibration. If the calibration is not performed,
you cannot adjust the monitor brilliance.
7. Access the [Common Installation Setting] menu and open the [Peripherals] win-
dow again.
8. Select the type of the printer from the [Printer Mode] pull-down list.
Setting option Remarks
[HP Officejet Pro 8000] Connect the printer to LAN1 port or USB port, and then set
[HP Officejet Pro 8100] the IP address of the printer to "192.168.31.241". For how to
[HP Officejet Pro 8210] set the IP address of the printer, see the operator’s manual
of the printer.
[HP Officejet 100 Mobile] Connect the printer to the USB port of the processor unit.
[HP Officejet 200 Mobile]

Note 1: For no printer, set [Printer Mode] to [HP Officejet 100 Mobile].
Note 2: The printer HP Officejet Pro 8000 Enterprise Printer can not be connected
to the processor unit.
9. Select the port that connects the printer from the [Printer Port] pull-down list.
Printer Printer Port
HP Officejet 100 Mobile/HP Officejet 200 Mobile/ [USB]
Not Connected
HP Officejet Pro 8000/HP Officejet Pro 8100/ [USB], [Network]
HP Officejet Pro 8210

USB: Only the processor unit connected to the printer can print.
Network: EC-3000s in the same network can print. The IP address of the printer
is shown on the [Printer] screen. Do not change the IP address.

10. To automatically print images captured with [Screenshot] function, check the
checkbox for [Auto Print out (SS)].
11. For the ECDIS, select the chart data storage equipment from the [Connection]
pull-down list in the [Chart Service] field. In this case, the IP address appears be-
low the [Connection] item. For the Chart Radar, the [Chart Service] field does not
appear. Go to the next step.
• [Not Connected]: Not connected to chart data storage equipment.
• [FURUNO]: Connected to the FURUNO Gate-1.
• [NAVTOR]: Connected to the NAVTOR NavBox.
• [NeCST]: Not used.

1-8
1. INITIAL SETTING AND ADJUSTMENT

12. To connect a service gateway, select [Connected] at [Service Gateway] then the
IP address and the port number appear below the [Connected] item. Do not
change these settings.
13. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].
Note 1: If the monitor does not display images correctly after system reboot, re-
boot the monitor.
Note 2: When the message shown below appears after system reboot, confirm
the connection and settings of the system.

1.2.3 [VDR] window


1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
2. Click [VDR] on the menu bar.

3. If a VDR is connected, select [Connected] from the [Connection] pull-down list.


Refer to the table below to set the items in the menu.
Menu item/
Description
interactive field
[Monitor] Select the DVI port connected with the VDR.
[Transmit per 15 sec.] Set the number of transmissions in 15 seconds.
[Transmission Rate] Set the transmitting rate.
[Image Format] Set the image format.
[JPEG Quality] Set the quality of JPEG data. Available when [JPEG] is se-
lected for [Image Format].
[Network] Select the network connected with the VDR.
[Transmission Timing] Set the delay timing. The delay is applied regardless of the
Display Mode selected (RADAR or Back-up ECDIS).
[Destination] Set the IP address and port of the destination.

1-9
1. INITIAL SETTING AND ADJUSTMENT

Menu item/
Description
interactive field
[Source] Set the status and information text, max. 16 characters.
[Location] Set the status and information text, max. 32 characters.
[Initial Value of Se- Set the initial value for the binary transmission sequence
quence No.] number (IEC61162-450 compliant) to be used when
transmitting video to a VDR.

4. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].

1.2.4 [Route Transfer] window


1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
2. Click [Route Transfer] on the menu bar.

3. To transfer data to a specified network, select [Connected] from the [Connection]


pull-down list.
Menu item Description
[Connection] Select [Connected] to transfer the data.
[Transmission Rate] Set the transmission rate.
[Network] Select the destination network for route data.
[Destination] Set the IP address and port of the destination.
[Initial Value of Sequence Set the initial value for the binary transmission se-
No.] quence number (IEC61162-450 compliant) to be
used when transferring route data to a device(s)
connected to the LAN.

4. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].

1.2.5 [Application] window


1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
2. Click [Application] on the menu bar.

1-10
1. INITIAL SETTING AND ADJUSTMENT

3. Select the primary display mode from the [Primary] pull-down list.
The primary display mode is displayed when you start the ECDIS. Also, the work-
ing indicator at the upper right changes according to the setting, and the spinner
can be clicked to return to the primary display mode.

: No setting. : [CONNING] is selected.

: [ECDIS] is selected. : [AMS] is selected.

: [RADAR] is selected.

Note: [AMS] is not available for Chart Radar systems.


4. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].

1.2.6 [Ship Name] window


1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
2. Click [Ship Name] on the menu bar.

3. Enter your ship information. The data entered here is included in any printing.
[Ship Name]: Own ship’s name. [Call Sign]: Own ship’s call sign
[IMO No.]: Own ship’s IMO no. [MMSI]: Own ship’s ID

Note: ECDIS and Chart Radar can display own ship’s data input from AIS, on the
[Own Ship] page in the [Nav Status] menu. The data entered here is not reflected
to the AIS data.
4. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].

1.2.7 [ECDIS/Radar] window

Menu item Description


[Calculate CPA/TCPA] Keep the default setting. Confirm that the checkbox has no check
mark. If there is a check mark, remove it.

1-11
1. INITIAL SETTING AND ADJUSTMENT

Menu item Description


[Use Legacy TTM ID] For ECDIS:
Determine the behavior when the TTM sentence contains a “0”
(zero). Refer to the table below and set according to the maker of
radar and the TTM ID range.
Radar TTM ID Recommended
maker range setting
00-99 Checked
FURUNO
01-200 N/A
00-99 Checked
01-99 N/A
Other maker
00-999 Not checked
01-999 N/A

Note 1: N/A means that the setting does not affect the operation
of FMD.
Note 2: When you connect the FURUNO radar, it is recommend-
ed to check the checkbox.

For Chart Radar:


When the checkbox is checked, the TT whose ID is “100” is out-
put with the ID “0”. This checkbox is used only when needed. For
example, the checkbox may be checked when a non-Furuno EC-
DIS is connected.
[RAMDISK Size (ADP- • [1GB (ECDIS)]: Select when the radar function is not used.
555-xx)] • [2GB (Radar/MFD)]: Select when the radar function is used.
Note: This menu item appears only when the CPU board of the
EC-3000 is “ADP-555-xx”. Also, this menu item is not shown for
FCR-2uu9.

1.2.8 [Language] window


The menu language for the everyday operating screens can be set to English or Jap-
anese. The [Common Installation Setting] menu has English menus only.

Note: This language setting is synchronized with all processor units on the network.
Reboot the synchronized processor unit(s) to use the selected menu language.
1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
2. Click [Language] on the menu bar.

3. Select [English] (default) or [Japanese].


4. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].

1-12
1. INITIAL SETTING AND ADJUSTMENT

1.3 [Own Ship Setting] Menu


Enter the information for ship parameters/CCRP, antenna unit, GPS sensor, AIS tran-
sponder, echo sounder (E/S), and SDME sensor. As for the symbol for sensors, there
are six colors to show the priority: white (CCRP), cyan (Radar), green (GPS), magenta
(AIS), orange (E/S) and blue (SDME) in that order.

1. Access the [Common Installation Setting] menu and click [Own Ship Setting] on
the tab bar.
2. Activate each field and enter own ship’s data, using the table below for reference.
Menu item/interactive field Description
[Vessel Type] Own ship type among [Fast/Super Small], [Fast/
Small], [Slow/Big] and [Super Tanker].
[Ship Length (LOA, m)] Own ship’s length, in meters.
[Ship Width (m)] Own ship’s width, in meters.
[Summer Load Line (m)] Distance between own ship’s hull and the summer
load line, in meters.
[MAX ROT (deg/min)] Own ship’s maximum angular velocity (Rate of turn).
[Block Coefficient] Own ship’s block coefficient.
[Min Maneuvering Speed (kn)] Minimum maneuvering speed. This value is used as
the threshold for the alert 159 "Low Speed Alarm".
The TCS is available when the vessel cruise at the set-
ting speed or more.
Note: Keep in mind the performance of the autopilot to
set the own ship’s minimum maneuvering speed.
[Center of Gravity] Own ship’s center of gravity, in meters, set by X, Y and
Z axis.
[Pivot Point] Own ship’s pivot point, in meters, set by X, Y and Z
axis. Approximately 80% of the ship’s length is recom-
mended for the pivot point. For example, the ship’s
length is 350 m, enter "280 m" to [Y (m)]. For TCS, the
XTE is calculated on the value set at here.
[CCRP] Select the [CCRP] you wish to setup by left-clicking the
check box to the left of each CCRP number. You can
set up a maximum of four CCRP positions. Set up of
[CCRP1] is required.

1-13
1. INITIAL SETTING AND ADJUSTMENT

3. Click [Radar Antenna] on the menu bar.

Note: When you set the value for [Antenna Position] on the [Installation Parame-
ters] menu, the setting value is shown at the right of [Equipment ID].
4. According to the number of antenna units connected to the processor unit, check
applicable checkbox to activate the antenna unit(s).
You can enter up to four antenna unit position data. Setting range: [RAS001] to
[RAS004]. Do not select [RAS005] to [RAS010]. Setup the antenna units activated
here on the [Installation Parameters] menu. See subsection 1.4.5 for details.
Note 1: Check all the antenna unit connected to the processor unit.
Note 2: For an FAR-2uu7 and FAR-2uu8 series radar antenna, set the antenna
no. (Equipment ID), taking care not to duplicate the Equipment ID of other radars.
For how to set the antenna no., see the installation manual of the radar.
5. Enter the position data of antenna unit(s) in the boxes [X (m)], [Y (m)], and [Z (m)].
Note: For the Chart Radar, the value of [Z (m)] is reflected in the default setting
on [MENU]o[1 ECHO]o[1 CUSTOMIZE ECHO]o[9 CONDITION]o[2 STC ANT
HEIGHT].
6. Enter the information for the GPS sensor, AIS transponder, echo sounder, and
SDME sensor in a similar manner.
Note 1: For the Chart Radar, [RAS001] (antenna unit), [GPS001] (GPS sensor),
[AIS001] (AIS transponder), and [LOG001] (SDME sensor) are activated by de-
fault. Enter their position data.
Note 2: When using the Radar Connection Box (RCB-002), make sure you input
the location information for the external radar antenna. Also, when multiple RCB-
002s are connected to the same network, change the IP address of the RCB-
002s, referring to "RCB-002 IP ADDRESS SETTING" on page AP-4.

1-14
1. INITIAL SETTING AND ADJUSTMENT

• [RCB00u (Main)] (u: 1 to 4): Input the location information of the external radar
antenna that is connected to the [RADAR SIGNAL IN No.1] port.
• [RCB00u (Sub)] (u: 1 to 4): Input the location information of the external radar
antenna that is connected to the [RADAR SIGNAL IN No.2] port. Set parame-
ters for the [RCB00u (Main)] before setting parameters for the [RCB00u (Sub)].

7. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.4 [Installation Parameters] Menu


The [Installation Parameters] menu sets the signals and input data of the sensors.
First, select the sensor data at the [Sensor Setting] window. Then select the sensor
from which the units (radar sensor (antenna unit), MFD, ECDIS, Radar, Chart Radar,
and Sensor Adapter) obtain the sensor data.

1.4.1 Sensor setting


1. Access the [Common Installation Setting] menu and click [Installation Parame-
ters] on the tab bar.
2. Click [Sensor Setting] on the menu bar, then click [GPS Sensor].

The time to timeout for receiving


data. Keep the default setting.

3. Check applicable check boxes according to the number of GPS receivers con-
nected.
4. Set the following items for the units activated at step 3.
Item Remarks
[SFID] Keep the default setting.
Do not use the "AI" prefix (AIS excluded) or the "II" prefix.
[Data Type] Sets the RX sentence data format.
Setting options: [IEC 61162-1 Ed3], [IEC 61162-1 Ed4], [IEC 61162-
1 Ed5], [ASCII], [BINARY], [MODBUS], [PSU]. Do not select [ASCII],
[BINARY] or [PSU].
[Strict/Loose] Sets the integrity of sentence data.
[Strict]: Confirm the validity of checksum, then receive sentence.
[Loose]: Receive sentence regardless of checksum invalidity.

1-15
1. INITIAL SETTING AND ADJUSTMENT

5. Click the [Details] button to set the following items, referring to the table shown be-
low.

For other units


For [VDR]
For [Other Sensor]

Item Remarks
[Sensor Name] Enter the appropriate sensor name.
[Manufacture] Select the manufacturer of sensor from the pull-down list.
Note: If the required manufacturer does not appear, add it
manually (see section 1.4.9).
[Sensor Type No.] Select the type of sensor from the pull-down list.
Note: If the required type does not appear, add it manually
(see section 1.4.9).
[System Alert ID] The identification number that is assigned in the system is
shown in this field. Do not change the setting.
[X (m)], [Y (m)], [Z (m)] Set the location of X, Y and Z for [Other Sensor] only.
[Alert Information Source] Set the source of alert definition to show on the display
when the alert message is received in an ALF sentence.
• [Alert Definition]: Show the alert definition registered to
the processor unit.
• [Alert Sentence]: Show the alert definition included in the
ALF sentence.
[ALF Text Information] Select the type of the 2/2 packet text information of ALF
sentence.
• [All Alert Name]: Select this item if all alert text is includ-
ed in the 2/2 packet of the ALF sentence. The text infor-
mation on the 2/2 packet of the ALF sentence is shown
as the alert name in the alert list/log.
• [Remaining Alert Name]: Select this item if the alert text
is divided in 1/2 and 2/2 packets of the ALF sentence.
The text information for both the 1/2 and 2/2 packets of
the ALF sentence is shown as the alert name in the alert
list/log.
• [Decision Support]: Select this item if the alert details in-
formation (Decision Support) is included in the 2/2 pack-
et of the ALF sentence. The text information for the 2/2
packet of the ALF sentence is shown as the alert details
in the alert list/log.
[Sensor Network] Set the IP address of sensor network for [VDR] only.
[Gateway Network] Set the IP address of gateway network for [VDR] only.

6. Set [Gyro Sensor], [ROT GYRO Sensor], [AIS Transponder], [Echo Sounder],
[SDME Sensor], [NAVTEX Receiver], [Water Temperature], [Wind Sensor], [Mag-
net Compass Sensor], [Current Sensor], [Rudder Sensor], [HCS], [VDR], [BN-
WAS], and [Other Sensor] in a similar manner.
Note 1: Only sensors connected to the processor unit should be set. For the Chart
Radar, the default sensor unit settings are as follows.

1-16
1. INITIAL SETTING AND ADJUSTMENT

Sensor Equipment ID Sensor Equipment ID


GPS Sensor GPS001 Wind Sensor -----
Gyro Sensor GYO001 Magnet Compass -----
Sensor
ROT GYRO Sensor ----- Current Sensor -----
AIS Transponder AIS001 Rudder Sensor -----
Echo Sounder ----- HCS -----
SDME Sensor LOG001 VDR -----
NAVTEX Receiver ----- BNWAS -----
Water Temperature ----- Other Sensor OTR001

Note 2: [OTR001] to [OTR004] are assigned for the four power supply units for
antenna unit. Only [OTR001] is selected by the default setting. When multiple ra-
dars are used, select Other Sensors all the same as [Equipment ID] of the antenna
units. For example, if the radar sensors [RAS001] and [RAS003] are used, check
the checkboxes of both [OTR001] and [OTR003].
7. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.4.2 Processor unit configuration


1. Select [ECDIS] or [Chart Radar] on the menu bar.

2. Check applicable checkbox to activate the corresponding processor unit. The


Equipment ID checked on this step is shown on the menu bar.
Each processor unit of ECDIS and Chart Radar has eight serial input/output, one
digital input and four digital output ports.
Note: Do not check processor units not used, to prevent trouble. Check only the
processor units to be used. The maximum number of processor units that can be
connected is shown below.

The number of The number of


Combination processor units processor units Total
(ECDIS) (Chart Radar)
Only ECDIS 16 - 16
ECDIS + Chart Radar 8 4 12
Only Chart Radar - 4 4

1-17
1. INITIAL SETTING AND ADJUSTMENT

3. Click the [Details] button and set the items referring to the following table.

For Chart Radar

For ECDIS

Item Remarks
[Subsystem] Set up sharing of sensor data through HUB-3000. For subsystem de-
tails, see page AP-3.
When sharing sensor data: Set the value. Setting range: “A” to “Z”.
To not share the sensor data: Keep the default setting (“---”).
[System Alert ID] The identification number that assigned in the system is shown in
this field. Do not change the setting.
[Alert Information Set the source of alert definition to show on the display when the
Source] alert message is received in an ALF sentence.
• [Alert Definition]: Show the alert definition registered to the proces-
sor unit.
• [Alert Sentence]: Show the alert definition included in the ALF sen-
tence.
[ALF Text Infor- Select the type of the 2/2 packet text information of ALF sentence.
mation] • [All Alert Name]: Select this item if all alert text is included in the 2/
2 packet of the ALF sentence. The text information for the 2/2
packet of the ALF sentence is shown as the alert name in the alert
list/log.
• [Remaining Alert Name]: Select this item if the alert text is divided
in 1/2 and 2/2 packets of the ALF sentence. The text information
for both the 1/2 and 2/2 packets of the ALF sentence is shown as
the alert name in the alert list/log.
• [Decision Support]: Select this item if the alert details information
(Decision Support) is included in the 2/2 packet of the ALF sen-
tence. The text information for the 2/2 packet of the ALF sentence
is shown as the alert details in the alert list/log.
[Planning]* Check the checkbox to assign the planning ECDIS. The planning
ECDIS is a master unit to share the route data. For details of sharing
the route data, see the operator’s manual of the ECDIS and Chart
Radar.
Note: Alerts are not displayed on the planning ECDIS.

1-18
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[VNC Connection No use.
Enable]*
[Sub Display
Mode]*
[Server IP Ad-
dress]*
[Server Port
Number]*
[Server Login
Password]*
[Additional Pa-
rameters]*
[Backup EC- Check the check-box to install the Chart Radar as a Back-up ECDIS.
DIS]**

*: ECDIS only
**: Chart Radar only
4. Click [Serial Input/Output] of [No.1 ECDIS] or [No.1 Chart Radar] on the menu bar.

[Serial 01] to [Serial 04] can input/output at 38,400 bps. For high-speed signal in-
put (such as AIS and Gyro) or TTD sentence output, click [Details] to set the baud
rate as 38,400 bps.
The connector no. on the I/O board of the processor unit EC-3000 and the corre-
sponding serial port no. are shown below.
Connector No. Serial Port No. Connector No. Serial Port No.
J3 Serial 01 J7 Serial 05
J4 Serial 02 J8 Serial 06
J5 Serial 03 J9 Serial 07
J6 Serial 04 J10 Serial 08

5. Check the applicable checkboxes of [Serial No.] according to sensor connection.


6. Set the items referring to the table shown below.
Item Remarks
[Equipment Select the Equipment ID from the pull-down list.
ID] The pull-down list options depend on the setting at [Sensor Setting].

1-19
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[Details] Sets the serial communication format.
• [Baud rate]: Sets the baud rate. For high-speed
signal input (such as AIS and Gyro) or TTD
output, set the baud rate as 38,400 bps The
available serial ports with communication in
38,400 bps are [Serial 01] to [Serial 04].
• [Data bit]: Sets the number of the data bit.
• [Parity bit]: Select [Odd] or [Even] for the parity
bit. The parity bit is used in parity error check-
ing to find errors during data transmission. For
no parity bit, select [None].
• [Stop bit]: Sets the stop bit (last data bit location).
• [Timeout (sec)]*1: When the data is not input during the time set here, tim-
eout alert occurs.
• [First Time]*2: Activate the checkbox to adjust the setting. Adjust the tim-
eout for detecting the first signal.
• [Continuation]*2: Activate the checkbox to adjust the setting. Adjust the
timeout for detecting a lost signal.
• [Slave Address]*2: Sets the slave address for the Modbus communication.
• [Input] button*2: Sets the address and the
signal bit for each alert on the [Modbus In-
put] window. On this window, alerts whose
[Input Type] is set for [MODBUS] when set-
ting alert definition (see section 1.8.6) ap-
pear.
• [Forward sensor data]*3: Check the check-
box to forward data input from the serial port to the sensor adapter. Nor-
mally keep the default setting (unchecked).
1
* : Not shown for the sensors whose [Data Type] is [MODBUS] (see
section 1.4.1), when the ECDIS or Sensor Adapter are set for serial input/
output.
*2: Shown for the sensors whose [Data Type] is [MODBUS] (see
section 1.4.1), when the ECDIS or Sensor Adapter are set for serial input/
output.
*3: Not shown for the sensors whose [Data Type] is [MODBUS] (see
section 1.4.1).
[I/F monitor] Click [Start] to monitor the input sentences from the interface.

1-20
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[Output] Sets the output sentence formats from the se-
rial port.
• [Output sentence whose destination corre-
sponds with this sensor.]: Check the check-
box to activate any of the following items.
• To output the ACK and HBT sentences in
response to the ALR sentence from the
external sensor.
• To output the ACN and HBT sentences in
response to the ALF sentence from the
external sensor.
• [Data Source]: Select the serial source from the pull-down list.
• [Formatter]: Input the formatter for serial output. Up to eight sentences can
be input for one source. For example, input “HDT,ROT” to set the HDT
and ROT sentences.
• [Thin Out]: Check the checkbox to output with a lower transmission rate
when forwarding data.
Note 1: The ECDIS and Chart Radar can send NAV STATUS (ship’s condi-
tion) and messages to an AIS transponder. Output the sentences VSD,
ABM, AIQ and BBM, when an AIS transponder is connected.
Note 2: Output the CRQ sentence to show the NAVTEX receiver mask in-
formation. For details about the NAVTEX receiver mask information, see the
operator’s manual.
Note 3: When the following setting is entered, the ECDIS or Chart Radar
outputs the EVE sentence. In this case, the maximum transmission cycle is
one second.
• [Data Source]: ECD***/ALERT or CRA***/ALERT
• [Formatter]: EVE
***: Changed according to the equipment ID.
[Filter] Activates or deactivates the input sentence filter.
Check the checkbox to use only the specified sen-
tences. For example, to use the HDT sentence
when the HDT and ROT sentences are received,
check the checkbox and enter “HDT” in the [Filter]
column.
Note: If it is not possible to input limit to the Talker,
enter ** (wild card), before sentence name. For ex-
ample, "**HDT".

7. Click [Digital Input] of [No.1 ECDIS] or [No.1 Chart Radar] on the menu bar.

The pin no. of J11 on the I/O board of the processor unit and the corresponding
input/output channel no. are shown below.
Pin No. Direction Channel No. Contact Status
5, 6 Output Channel 01 Normal Close
7, 8 Output Channel 02 Normal Close
9, 10 Output Channel 03 Normal Open
11, 12 Output Channel 04 Normal Open
15, 16 or 14, 15 Input Channel 01 Depended on the configuration.

1-21
1. INITIAL SETTING AND ADJUSTMENT

8. Check the checkbox of [Channel No.].


9. Set the items referring to the table shown below.
Item Remarks
[Data Cate- Sets the data category. Settings: [ALERT], [ACK], [BUZZER STOP], [OP-
gory] ERATOR FITNESS], [OTHER], [GYRO SELECTOR], [MOB].
[+] button This appears when the [Data Category] is set to [ALERT]. Click to show
the configuration of the alert input.

Example: ALR is the alert notification sentence.


• [Equipment ID]: The Equipment ID is shown.
• [Alert ID]: The alert notification sentence* (ALF or ALR) and alert num-
ber are shown. When the alert notification sentence is ALF, the in-
stance ID is shown.
*: According to the connected sensors.
• [ ] button: Opens the [Alert No. Setting] window to select the input
alert. The following example uses the alert notification sentence ALR.
Select the Equipment ID for the connected sensors from the [Equip-
ment ID] pull-down list. Then check the radio button of the desired alert
and click the [OK] button.

㻱㻯㻰㻜㻜㻝

• [Alert Name]: The alert name is shown.


[Equipment Select the Equipment ID from the pull-down list. This appears when the
ID] [Data Category] is set to [ACK] or [BUZZER STOP].
The pull-down list options change according to the setting at [Sensor Set-
ting].
[Details] • [Name]: Enter the appropriate sensor
name.
• [Data Type]: Set the contact input ([Nor-
mally Open] or [Normally Closed]).
• [Input Time (100msec)]: Set the input
time (recommended value: 5).
• [Dead Band (100msec)]: Set the dead
band after input (recommended value:
50).
• [Calibration Active]: Keep the default
setting. (Default: without check)
• [Active Status (1)], [Active Status (0)]: Keep the default setting.

1-22
1. INITIAL SETTING AND ADJUSTMENT

10. Click [Digital Output] of [No.1 ECDIS] or [No.1 Chart Radar] on the menu bar.

For the pin no. of J11 on the I/O board of the processor unit and the corresponding
input/output channel no., see the table on step 7.
11. Check the checkbox for [Channel No.].
12. Set the items referring to the table shown below.
Item Remarks
[Data Cate- Sets the data category. Settings: [ALERT], [ACK], [BUZZER STOP], [OP-
gory] ERATOR FITNESS], [OTHER], [TRANSFER], [BACKUP NAVIGATOR].
[+] button This appears when the [Data Category] is set to [ALERT]. Click to show
the configuration of the alert output.

Example: ALF is the alert notification sentence.


• [Equipment ID]: The Equipment ID is shown.
• [Alert ID]: The alert notification sentence* (ALF or ALR) and alert num-
ber are shown. When the alert notification sentence is ALF, the in-
stance ID is shown.
*: According to setting of [Output Data Type for INS] in the [AMS] menu
(see section 1.7).
• [ ] button: Opens the [Alert No. Setting] window to select the output
alert. The following example uses the alert notification sentence ALF.
Check the radio button of the desired alert and click the [OK] button.

• [Alert Name]: The alert name is shown.


[Equipment Select the Equipment ID from the pull-down list.
ID] The pull-down list options change according to the setting at [Sensor Set-
ting].

1-23
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[Details] • [Name]: Enter the appropriate sensor
name.
• [Data Type]: Set the contact output.
[Normally Open] is for [Channel 01] to
[Channel 02], [Normally Closed] is for
[Channel 03] to [Channel 04].
Note: [Data Type] is not shown for the
Sensor Adapter setting.
• [Output Time (100msec)]: Set the out-
put time (recommended value: 10).
• [Dead Band (100msec)]: Set the dead
band after output (recommended value: 5).
• [Calibration Active]: Keep the default setting. (Default: without check)
• [Active Status (1)], [Active Status (0)]: Keep the default setting.

13. Repeat the procedures from step 4 to enter the settings to another processor unit.
14. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.4.3 Activating the connection with the processor unit of the FAR-
2uu8 series radar (ECDIS only)
1. Click [Radar] on the menu bar.

RAD001 through RAD010 are not used.

2. Check the check box for each FAR-2xx8 series radar processor unit to be con-
nected. Setting range: [RAD111] to [RAD118]
The Equipment ID checked on this step is shown on the menu bar.
Note: Do not use [RAD001] to [RAD010].

1-24
1. INITIAL SETTING AND ADJUSTMENT

3. Click the [Details] button to set the following items, referring to the table shown be-
low.

Item Remarks
[Equipment Name] Enter the name of the equipment.
[Equipment Type Shows the equipment type number.
No.]
[SFID] Keep the default settings.
[System Alert ID] The identification number that is assigned in the system is shown
in this field. Do not change the setting.
[Alert Information Set the source of alert definition to show on the display when the
Source] alert message is received in an ALF sentence.
• [Alert Definition]: Show the alert definition registered to the pro-
cessor unit.
• [Alert Sentence]: Show the alert definition included in the ALF
sentence.
Note: Be sure to set [Alert Sentence]. An FAR-2uu8 alert will not
be displayed in the AMS mode unless [Alert Sentence] is set.
[ALF Text Informa- Select the type of the 2/2 packet text information of ALF sentence.
tion] • [All Alert Name]: Select this item if all alert text is included in the
2/2 packet of the ALF sentence. The text information on the 2/
2 packet of the ALF sentence is shown as the alert name in the
alert list/log.
• [Remaining Alert Name]: Select this item if the alert text is di-
vided in 1/2 and 2/2 packets of the ALF sentence. The text in-
formation for both the 1/2 and 2/2 packets of the ALF sentence
is shown as the alert name in the alert list/log.
• [Decision Support]: Select this item if the alert details informa-
tion (Decision Support) is included in the 2/2 packet of the ALF
sentence. The text information for the 2/2 packet of the ALF
sentence is shown as the alert details in the alert list/log.
[Sensor Network] Shows the IP address of the sensor network. Do not change the
setting.
[Gateway Network] Shows the IP address of the gateway network. Do not change the
setting.
[Radar Sensor] Select the Equipment ID of the antenna unit connected with the
processor unit.

4. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-25
1. INITIAL SETTING AND ADJUSTMENT

1.4.4 Sensor Adapter configuration


A maximum of eight Sensor Adapter MC-3000S can be connected to the sensor net-
work. In case of the redundant configuration, sixteen Sensor Adapters can be con-
nected to the network. The MC-3000S can connect a max. ten additional units (MC-
3010A/3020D/MC-3030D). Note that a maximum of five MC-3010A can be connected
to MC-3000S.

1. Click [Sensor Adapter] on the menu bar.

*: Select the talker ID for sentences output from the Sensor Adapter (II or SI).
Normally, keep the default setting ("II"). Select "SI", only when the talker ID must be
changed.
2. Check the check box of [MCV001] to activate.
3. Click [Details] to display the window as shown below. For the descriptions of the
each items, see step 3 of section 1.4.2.

4. Click [No.1 Sensor Adapter] on the menu bar.


The Sensor Adapter consists of four sub units: [Serial Input/Output], [Digital Input]*,
[Digital Output]*, and [Analog Input]*.
*: Not shown when you access the MC-3000S directly. Access the EC-3000 to ad-
just the setting for digital input, digital output and analog input.

1-26
1. INITIAL SETTING AND ADJUSTMENT

5. Click [Serial Input/Output]. There are eight ports in the Serial Input/Output. [Serial
01] to [Serial 04] can input/output at 38,400 bps for the AIS and Gyro or TTD out-
put.

The connector no. on the MC-3000S board and the corresponding serial port no.
are shown below.

Connector No. Serial Port No. Connector No. Serial Port No.
J4 Serial 01 Serial 05
J8
J5 Serial 02 Serial 06
J6 Serial 03 Serial 07
J9
J7 Serial 04 Serial 08

6. Set the items referring to step 6 of section 1.4.2.


7. Click [Digital Input] on the menu bar.

[Channel 01-01] to [Channel 01-08] are shown on the display. Each Sensor
Adapter MC-3020D has eight input ports. When one Sensor Adapter MC-3020D
is connected to the MC-3000S, [Channel 01-01] to [Channel 01-08] can be used.
When ten Sensor Adapters MC-3020D are connected, [Channel 01-01] to [Chan-
nel 10-08] can be used.
The connector no. on the MC-3020D board and the corresponding channel port
no. are as follows:

1-27
1. INITIAL SETTING AND ADJUSTMENT

No.1 Sensor Adapter MC-3020D


Connector No. Channel No. Connector No. Channel No.
Channel 01-01 Channel 01-05
J3 J5
Channel 01-02 Channel 01-06
Channel 01-03 Channel 01-07
J4 J6
Channel 01-04 Channel 01-08

No.2 Sensor Adapter MC-3020D


Connector No. Channel No. Connector No. Channel No.
Channel 02-01 Channel 02-05
J3 J5
Channel 02-02 Channel 02-06
Channel 02-03 Channel 02-07
J4 J6
Channel 02-04 Channel 02-08

8. Check the checkbox for [Channel No.] to set the items referring to step 9 of
section 1.4.2.
9. Click [Digital Output] on the menu bar.

[Channel 01-01] to [Channel 10-08] are shown on the display. Each Sensor
Adapter MC-3030D has eight input ports. When one Sensor Adapter MC-3030D
is connected to the MC-3000S, [Channel 01-01] to [Channel 01-08] can be used.
When ten Sensor Adapters MC-3030D are connected, [Channel 01-01] to [Chan-
nel 10-08] can be used.

The connector no. on the MC-3030D board and the corresponding serial channel
are shown below.
No.1 Sensor Adapter MC-3030D
Connector No. Channel No. Connector No. Channel No.
Channel 01-01 Channel 01-05
J3 J5
Channel 01-02 Channel 01-06
Channel 01-03 Channel 01-07
J4 J6
Channel 01-04 Channel 01-08

No.2 Sensor Adapter MC-3030D


Connector No. Channel No. Connector No. Channel No.
Channel 02-01 Channel 02-05
J3 J5
Channel 02-02 Channel 02-06
Channel 02-03 Channel 02-07
J4 J6
Channel 02-04 Channel 02-08

1-28
1. INITIAL SETTING AND ADJUSTMENT

10. Check the checkbox for [Channel No.] to set the items referring to step 12 of
section 1.4.2.
11. Click [Analog Input] on the menu bar.

[Channel 01] to [Channel 15] are shown on the display. Each Sensor Adapter MC-
3010A has three input ports. When one Sensor Adapter MC-3010A is connected
to the MC-3000S, [Channel 01] to [Channel 03] can be used. When five Sensor
Adapters MC-3010A are connected, [Channel 01] to [Channel 15] can be used.
The connector no. on the MC-3010A board and corresponding serial port no. are
shown in the following table.
No.1 MC-3010A
Connector No. Channel No.
J3 Channel 01
J4 Channel 02
J5 Channel 03

No.2 MC-3010A
Connector No. Channel No.
J3 Channel 04
J4 Channel 05
J5 Channel 06

12. Check the checkbox for [Channel No.] to set the items referring to the table shown
below.
Item Remarks
[Sensor Name] Enter an appropriate name that indicates sensor’s function.
[Data Type] Sets the input data type. Setting range: -10-10V, 0-10V, 4-20mA.
Note: For [4-20mA], fix the jumper to the connector (J3 to J5). See the
installation manual of ECDIS or Chart Radar.

1-29
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[Details] • [Sensor Type No.]: Enter the sensor
type.
• [Data Name]: Enter the appropriate
data name.
• [Calibration Active]: Check the check
box to display the analog input data
on the conning display and show the
lower columns.
• [Calibration Point1(2)]: Enter input
voltage (or current).
• [Calibration Point Value1(2)]: Enter
the value to show on the conning display. In the example above, the
conning display shows “0” for 0V; “120” for shown for 10V.
Note: For input current, enter the value in ampere units (A).

13. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.4.5 Antenna unit configuration


Do the procedure here to set the antenna unit.

1. Click [Radar Sensor] on the menu bar.


2. Confirm that the Equipment ID checked at the [Own Ship Setting] menu (see
section 1.3) is activated.

3. Click the [Details] button to show the [Details Setting] window.


4. Set the appropriate antenna position from the [Antenna Position] pull-down list.
The interswitch function requires correct input of the antenna position.

Select the appropriate


position.

5. Click the [OK] button.


6. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-30
1. INITIAL SETTING AND ADJUSTMENT

7. For FCR-2uu9 or FAR-2uu7 series antenna unit, perform the self test to confirm
that the SPU program version and DIP switch setting are as shown below.
For FCR-2uu9 series
Open the [System Monitor] menu (see section 1.11), then click the [Self-test] but-
tono[Radar Sensor (FCR-2uu9)]o[Sensor Status].
[SPU Software Version]: 0359204-03.50, or after
[SPU DIP switch (SW16-SW1)]: 0100
For FAR-2uu7 series
Perform the self test, referring the operator’s manual of FAR-2uu7 series radar.
[SPU PROGRAM NO.]: 0359204-03.50, or after
[DIP SW]: 1000 or 1001

1.4.6 Radar connection box configuration (ECDIS only)


You can display echoes from non-Furuno radars by connecting them to the ECDIS
through the Radar Connection Box RCB-002. A maximum of four RCB-002s can be
connected to this system.

Set the location information of the external radar antenna on the [Own Ship Setting]
menu (see page 1-14) before doing the procedure shown below.
Note: When multiple RCB-002s are connected to the same network, change the IP
address of the RCB-002s, referring to "RCB-002 IP ADDRESS
SETTING" on page AP-4.
1. Click [Radar Connection Box] on the menu bar.

2. Click the check box for [RCB00u (Main)] (u: 1 to 4). This box must be checked to
use the radar connection box.
3. When you connect two external radars to the radar connection box, click the
check box for [RCB00u (Sub)] (u: 1 to 4).
4. Click the [Details] button and set the following items.

For “Main” radar For “Sub” radar

1-31
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[SFID] Keep the default setting.
[DATA Type] Sets the RX sentence data format.
Setting options: [IEC 61162-1 Ed3], [IEC 61162-1 Ed4], [IEC 61162-
1 Ed5]
[Strict/Loose] Sets the integrity of sentence data.
[Strict]: Confirm the validity of checksum, then receive sentence.
[Loose]: Receive sentence regardless of checksum invalidity.
[Antenna Posi- Set the location for the antenna units of the external radar that is con-
tion/] [Sub An- nected to the radar connection box.
tenna Position] Setting options: [Fore], [Main Top], [Main 2nd], [Main 3rd], [Aft], [Port],
[Starboard].

5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.4.7 Monitoring of HUB


To monitor the HUB, do as follows.

1. Click [HUB] on the menu bar.

2. Set the items referring to the table shown below.


Item Remarks
[Status polling interval (1~300 sec)] Polling interval for the HUB connection status re-
quest.
[Status polling timeout (1000~10000 Time to wait for the HUB connection status re-
ms)] sponse.
[Status polling retries (1~10 times)] Retry times to request the HUB connection sta-
tus.
[Threshold to alert (1~10 times)] The number of times the HUB link is lost to wait
before generating an alert.
[Monitoring Type] Select the origin point for alerts when there is a
connection error with the HUB-3000.
• [Monitor Ports]: Equipment connected to the
HUB-3000 detects disconnection of other
equipment and releases the alert.
• [Monitor Units]: The disconnected equipment
releases the alert.

3. Check the checkbox for the HUB(s) to activate.

1-32
1. INITIAL SETTING AND ADJUSTMENT

4. Click the [Details] button to open the [Details Setting] window and enter the appro-
priate items.
• [Equipment Name]: Enter the name of the
HUB.
• [IP Address]: Select the network and IP
Address of the HUB from the pull-down list.
• [Community]: Set the parameters for
SNMP protocol. This setting must be the
same as set at the HUB.
5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.4.8 Signal and Port setting for external equipment


This connection setting menu can set the serial I/O for external equipment, the analog
input for Sensor Adapter, and HUB port.

1. Click [Connection Setting] on the menu bar.


2. Click [Serial Input/Output Setting] on the menu bar.
The serial input/output settings are shown. The settings can be changed, referring
to step 6 of section 1.4.2.

3. Click [Analog Input Setting] on the menu bar.


The analog settings are shown. The settings can be changed, referring to step 12
of section 1.4.4.

4. Click [HUB Setting] on the menu bar.


The alert settings of each port of the HUBs are shown. The display is changed ac-
cording to the [Monitoring Type] setting. For details of [Monitoring Type], see
page 1-32.

1-33
1. INITIAL SETTING AND ADJUSTMENT

• Where [HUB Port Setting] ([Monitoring Type] = [Monitor Ports])

Item Remarks
Checkbox Check the checkbox for the port which generates the alert
when the connection is interrupted.
[Port] HUB port number.
[Alert No.] When the alert notification sentence is in ALR format, the
alert number is shown.
When the alert notification sentence is in ALF format, the
alert number and the Instance ID are shown.
Click the [ ] button to open the [Alert No. Setting] win-
dow. Set the output alert on the [Alert No. Setting] window.
Check the radio button for the desired alert and click the
[OK] button.
[Alert Name] Alert name of each HUB port

• Where [HUB Alert Setting] ([Monitoring Type] = [Monitor Units])

Item Remarks
[Alert No.] When the alert notification sentence is in ALR format, the
alert number is shown.
When the alert notification sentence is in ALF format, the
alert number and the Instance ID are shown.
Click the [ ] button to open the [Alert No. Setting] win-
dow. Set the output alert on the [Alert No. Setting] window.
Check the radio button for the desired alert and click the
[OK] button.
[Alert Name] Name of the alert set for each port.
Drop down list Select the equipment ID(s) for the equipment connected
with the HUB-3000.

5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-34
1. INITIAL SETTING AND ADJUSTMENT

1.4.9 Customized sensor setting


Set the sensor types and manufacturers in the [Sensor Setting] menu.

1. Click [User Sensor Model List] on the menu bar.


2. Click the appropriate sensor to edit. The figure below shows an example where
the [GPS Sensor] is selected.

Item Remarks
[Built-in Sensor Displays the sensor types and manufacturers preset already.
Model List] [Manufacture]: Manufacturer of sensor
[Sensor Type No.]: Type of sensor
[User Sensor Click the [New] button to add a new type or manufacturer of sensor.
Model List] Enter the desired manufacturer name and the desired type of sen-
sor, then click the [OK] button.

Click the [Delete] button to delete the added contents. The confirma-
tion message appears, then click the [OK] button.
Note: The contents added or deleted in this setting are applied to the
[Sensor Setting] menu. See section 1.4.1.

3. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-35
1. INITIAL SETTING AND ADJUSTMENT

1.4.10 Settings to activate the shuttle ferry mode (Chart Radar only)
The external switch for the shuttle ferry mode should be registered as "Other Sensor".

Note: When there is a FMD-3u00 with Radar mode activated in the same network, the
shuttle ferry mode is not available.
1. Select [Sensor Setting] o [Other Sensor], then check the appropriate Other Sen-
sor checkbox for the port to be used as the external switch.

2. Open the [Serial Input/Output] setting window of the EC-3000 to be used for the
shuttle ferry mode.
3. Activate the serial port to be connected the external switch for the shuttle ferry
mode, then select the Equipment ID selected at step 1.
In the following example, "Serial 05" is connected to the external switch for the
shuttle ferry mode (OTR005).

4. Click the [Details] button for the serial port


that was activated at step 3, then set the
output sentence as follows:
• [Data Source]: Equipment ID of the EC-
3000 to be used for the shuttle ferry
mode.
• [Formatter]: FEC/cclbk

5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-36
1. INITIAL SETTING AND ADJUSTMENT

1.5 [CCRS] Menu

1.5.1 How to select the [Data Source]


1. Access the [Common Installation Setting] menu and click [CCRS] on the tab bar.
2. Click the [Position] directly item below [Data Source Setting] on the menu bar.

*: Position, Heading, STW, COG/SOG, Rate of Turn: Keep the default


setting (3000). For other than the above settings, set “30000” (30 sec.).
3. Select the data source in order of priority from the [Data Source] pull-down list.
The Equipment IDs checked at [Installation Parameters] menu are shown on the
pull-down list.
When entering the data source, the [Formatter] is automatically entered.
Note: When more than two [Data Source] and [Formatter] are entered, the top-
most entry has the highest priority.
4. Set [Time], [Depth(Bow)], [Depth(Midship)], [Depth(Stern)], [Heading], [Rudder],
[Wind Speed/Direction], [STW(absolute)] (speed through water), [STW(position)]
(speed through ground), [COG/SOG], [Heading Magnetic], [Water Temperature],
[Current], and [Rate of Turn] in a similar manner.
Note: For the processor unit of the Chart Radar, the default data sources are as
follows:
Item Data Source Remarks
Position GPS001
Time GPS001
Depth(Bow) -----
Depth(Midship) -----
Depth(Stern) -----
Heading GYO001
Rudder -----
Wind Speed/Direction -----
STW(absolute) LOG001 Speed through water
STW(position) LOG001 Speed through ground
COG/SOG GPS001
Heading Magnetic -----
Water Temperature -----
Current -----
Rate of Turn -----
Transmission Group Setting See subsection 1.5.2.

5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-37
1. INITIAL SETTING AND ADJUSTMENT

1.5.2 How to set [Transmission Group]


When connecting IEC61162-450 compatible sensors, you may need to adjust [Trans-
mission Group Setting]. Under normal circumstances, you do not need to adjust these
settings. When adjusting items in [Transmission Group Setting] menu, you will need
to configure for all devices in the configuration.

1. Access the [Common Installation Setting] menu, then click [CCRS] on the tab bar.
2. Click [Transmission Group Setting] on the menu bar.

2
3

No. Item Description


[Transmission Group name] Click the Transmission Group name to show the
1
Setting List.
2 [Set Default (All Groups)] Revert all Transmission Groups to default settings.
[Set Default (This Group)] Revert the selected Transmission Group to default
3
settings.

3. Select a Transmission Group from the menu bar.

Example: Transmission Group Settings for MISC.


4. In the [Transmission Group Talker] fields, remove or add entries as appropriate.
5. Select and adjust other Transmission Group settings as appropriate.
6. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-38
1. INITIAL SETTING AND ADJUSTMENT

Default settings for each Transmission Group

Transmission Group Talker Multicast Address Multicast Port


BI
DU
ER
II
NL
RC
SG
SS
UP
U0
U1
MISC 239.192.0.1 60001
U2
U3
U4
U5
U6
U7
U8
U9
VR
YX
SI
AI
TGTD 239.192.0.2 60002
RA
HE
SATD HN 239.192.0.3 60003
TI
AG
AP
DF
EC
EI
GA
GP
GL
GN
NAVD HC 239.192.0.4 60004
HF
IN
LC
SD
SN
VD
VM
VW
WI

1-39
1. INITIAL SETTING AND ADJUSTMENT

Transmission Group Talker Multicast Address Multicast Port


BN
FD
FE
FR
VDRD FS 239.192.0.5 60005
HD
HS
WD
WL
CD
CR
CS
RCOM CT 239.192.0.6 60006
CV
CX
EP
ZA
ZC
TIME 239.192.0.7 60007
ZQ
ZV
PROP - 239.192.0.8 60008
USR1 - 239.192.0.9 60009
USR2 - 239.192.0.10 60010
USR3 - 239.192.0.11 60011
USR4 - 239.192.0.12 60012
USR5 - 239.192.0.13 60013
USR6 - 239.192.0.14 60014
USR7 - 239.192.0.15 60015
USR8 - 239.192.0.16 60016

1.5.3 [CCRS Setting] window


Set if the NSR sentence is output from the CCRS in the [CCRS Setting] window of the
[CCRS] menu. This setting is currently unavailable. Confirm that the box has no check
mark.

Remove the checkmark.

1-40
1. INITIAL SETTING AND ADJUSTMENT

1.6 [TCS] Menu


The [TCS] menu adjust the settings relevant to the TCS (Track Control System). The
TCS is available with the FMD-3200/FMD-3300/FMD-3200-BB only. For Chart Ra-
dars, only the settings on the [Other Setting] window are required (see section 1.6.7).

*
: Shown when [YOKOGAWA] is selected for [Manufacture].
The autopilots shown below are available for the TCS with the FMD-3200/FMD-3300/
FMD-3200-BB.

Manufacture Model
Raytheon Anschutz NP-5400
Yokogawa Electric PT-500A
Corporation PT900
TOKYO KEIKI PR-6000
PR-9000
EMRI FAP-2000
FAP-3000

1.6.1 Preparation
Notice for the sensor data
Connect the sensor data shown below to the serial port of the ECIDS directly.

• Gyro • GPS • LOG • Autopilot

Confirmation of the dongle


Connect the TCS-compliant dongle to use the TCS. For how to confirm if the dongle
is TCS-compliant or not, see the [System] tab of [About] screen or [Self Test] page.

1-41
1. INITIAL SETTING AND ADJUSTMENT

• Confirmation on the [About] screen


1. Click the [ ] button on the status bar.

2. Click [About] to show the [About] screen.


3. Click the [System1] tab.
4. Confirm if "tcs" appears in the [Function] field.

• Confirmation on the [Self Test] page

1. Click [ ] on the status bar then select [Settings].


The message shown below appears.

2. Click [OK] to show the [Settings] menu.


3. Click the [Self Test] tab to show the [Self Test] page.
4. Confirm if "tcs" appears in the [Function] field.

1-42
1. INITIAL SETTING AND ADJUSTMENT

1.6.2 How to set the TCS for autopilot


1. Access the [Common Installation Setting] menu and click [Installation Parame-
ters] on the tab bar.
2. Click [HCS] on the menu bar.
3. Check the checkbox of [HCS001].

4. Open the [Serial Input/Output] setting window of the ECDIS processor unit con-
nected to the autopilot.
Note: Connect the autopilot to the ECDIS processor unit that has the TCS-com-
pliant dongle.
5. Check the checkbox of the [Serial No.] (serial port no.) connected to the autopilot.
6. Select [HCS001] from the [Equipment ID] pull-down list of [Serial No.] checked at
step 5.

Example 䠖 Connect the autopilot to the serial port 5 of the No.1 ECDIS
7. Click [Output] to show the [Serial Output Setting] window.
8. Set [Data Source] to the Equipment ID of the ECDIS processor unit connected to
the autopilot.
9. Enter the sentences to [Formatter] according to the manufacturer and model of
the autopilot.
Manufacturer Model Sentence Display example
Raytheon NP-5400 • APB
Anschutz • HTD
APB
• PANZCRQ HTD

• PANZEST PANZCRQ

• PANZPSR
PANZEST
PANZPSR

• PANZHTD PANZHTD

Yokogawa PT-500A • HTC


Electric • XTE
Corporation • VBW
• FRN

1-43
1. INITIAL SETTING AND ADJUSTMENT

Manufacturer Model Sentence Display example


Yokogawa PT-900 • HTC
Electric • XTE
Corporation • VBW
• VTG

TOKYO KEIKI PR-6000 • HTC


or • XTE
PR-9000 • VBW
• VTG
• HSC
• FRN

EMRI FAP-2000 • ESS


or
FAP-3000

10. Open the [Digital Output Setting] window of the ECDIS connected to the autopilot.
11. Check the channel no. connected to the BNWAS (Bridge Navigation Watch Alarm
System).
12. Set [Data Type] and [Data Category] as shown below.
• [Data Type]: According to the BNWAS, select [NO] (Normal Open) or [NC] (Nor-
mal Close).
• [Data Category]: Select [BACKUP NAVIGATOR].
13. Click [CCRS] on the menu bar.
14. For the sensor data listed below, register the data source and filter, with Priority
of Data Source on the CCRS menu.
The filter must be set to No.1 priority. For example, when No.1 ECDIS connected
to the autopilot, set the filter "ECD001/FILTER (IN0001)" to No.1 priority.
• Position
• STW (absolute)
• STW (position) Set the filter to
• COG/SOG No.1 priority.
• Rate of Turn

Example: For the position data

15. Click [TCS] on the menu bar.

1-44
1. INITIAL SETTING AND ADJUSTMENT

16. Set [Basic Setting] referring to the table shown below.


Setting Option Remarks
Primary Select the Equipment ID of the primary ECDIS.
ECDIS
Secondary Select the Equipment ID of the secondary ECDIS.
Manufacture Enter the manufacturer of the autopilot.
Autopilot
Model Enter the type of the connected autopilot.

17. See section 1.3 to enter the information for ship parameters.
18. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
After saving the configuration, reboot the ECDIS processor unit connected to the
autopilot to enable the [TCS] button in the Voyage navigation mode.

1.6.3 How to set the Navigation Parameter


When you active the TCS, set the Navigation Parameter. After setting the Navigation
Parameter, the configuration can be copied to other processor units connected to the
network.

1. In the chart mode, press Ctrl, Shift and t keys simultaneously on the control unit
or keyboard.
The password input dialog box appears.

2. Enter the password and click [OK].


Note: The service mode remains enabled until you press Ctrl, Shift and t keys
simultaneously or reboot the unit.
3. Click [MENU] to open the menu.
4. Click [Navigation Parameter] to show the [Navigation Parameter] setting window.

5. Enter [SPD kn] (ship speed), [Radius NM] (turning radius) and [FWD DIST NM]
(forwarding distance*).
*: The distance the ship travels straight after the steering control is send to the au-
topilot.

1-45
1. INITIAL SETTING AND ADJUSTMENT

6. When [FWD DIST NM] is different between port and starboard sides, check the
checkbox of [Use different values for Port and Starboard] and then enter each set-
ting value.

7. Confirm the TCS is stopped and click [Save] to save the Navigation Parameter.
Note: When you click [Save] while the TCS is activated, the TCS is force-quitted.

[Service State] button


When the TCS is activated in the service mode, the [Service State] button is enabled
on the [Navigation Parameter] setting window. The gain value is changed to minimum
value and the XTE correction is invalid when you click the [Service State] button. Use
the [Service State] button to adjust [FWD DIST NM].

Note: Use the [Service State] button while the ship is turning. The vessel may go off
the route because the XTE correction is invalid.
[Service State] button

1. Enter the value comparable to the ship’s length to [FWD DIST NM] on the [Navi-
gation Parameter] setting window.
2. Activate the TCS and monitor any route.
3. When the vessel comes up to WOL, click the [Service State] button.

1-46
1. INITIAL SETTING AND ADJUSTMENT

4. After the turn of the vessel, click the [Service State] button again.
When the turn of the vessel goes long, raise the setting value of [FWD DIST NM].
When the turn of the vessel goes sharp, lower the setting value of [FWD DIST
NM].

Own ship
Route When the turn of the vessl goes long

When the turn of the vessl goes sharp

[Check Required] checkbox

For the DNV class boat,


check this checkbox.

When you check the checkbox of [Check Required] on the [Function1] tab of the [Ship
& Route Parameters] setting window, a route that is not checked for safe navigation
can not be monitored. For the DNV class ship, check this checkbox.

Note: The route shown below can not be monitored regardless the setting of this
checkbox.
• The route that have one waypoint or no waypoint.
• The route that have impossible turns.

How to confirm the connection between the ECDIS and autopilot


Confirm the connection between the ECDIS and autopilot by simulating the TCS func-
tion in the service mode. When simulating the TCS function, the vessel can not turn.

1. Click [Interface Test] button on the [Function1] tab of the [Ship & Route Parame-
ters] setting window.

Click [Interface Test] button.

1-47
1. INITIAL SETTING AND ADJUSTMENT

2. Click [System/Local Select] on the menu.


3. Select [Local Sensor], and then click Save button.

4. Click [Local Sensor Setting] on the menu.


5. Open the [SPD] tab to set [Stabilization Mode] to [Water].
6. Set [Data Source] to [Manual] to enter any ship’s speed value.
7. Check the checkbox of [Set Drift] to enter any speed and course of drift.

Select [Manual].
㻼㻾㻵㻹㻦
㻿㻼㻰㻦

Enter ship’ s speed.

Enter speed and


course of drift.

8. Open the [POSN] tab to set [Data Source] to [Manual].


9. Enter any position data on the dialog box shown below.

㻼㻾㻵㻹㻦
㻸㻭㼀㻦
㻸㻻㻺㻦

㻸㻭㼀㻦
㻸㻻㻺㻦
Enter the position data.

1-48
1. INITIAL SETTING AND ADJUSTMENT

10. Click the [Save] button. According to the data that you entered, the information of
the sensor information box is updated.

Example: Sensor information box


Note: For the heading data, use the data input from the heading sensor.
11. Monitor the route that the vessel is in the channel limit.
12. According to the autopilot connected with the ECDIS, do the following procedure.
For FAP-3000, PR-6000 or PR-9000
Click the [TCS], [TCS Setting] button and se-
TCS TCS
lect [Go AW] or [Go SEA] on the InstantAc- TCS
Setting State

cess bar™. Go
AW
Select [Go AW] or
Go [Go SEA].
SEA

For PT-900 or NP-5400


Click the [TCS], [OP] button and select [Go
TCS
AW] or [Go SEA] on the InstantAccess TCS OP
Status

bar™. Go
AW
Select [Go AW] or
Go [Go SEA].
SEA

For FAP-2000 or PT-500A


At the autopilot, push the Go AW or Go SEA button as appropriate.
13. Change the steering mode of the autopilot to NAV mode.
14. Confirm that [Go AW] or [Go SEA] appears at the [TC] column of the route infor-
mation box.
• [Go AW] or [Go SEA] appears:
The connection between the
ECDIS and autopilot is correct.
• [Go AW] or [Go SEA] does not
appear: Check the configuration
XTD Limit:
and connection between the
XTD:
ECDIS and autopilot. Confirm that [Go
AW] or [Go SEA]
2.20 NM appears.

1.00 NM

Example: Route information box

1-49
1. INITIAL SETTING AND ADJUSTMENT

1.6.4 Multiple ECDIS and autopilot control


The ECDIS is connected to the autopilot via a hardware switch to permit manual
switching of the ECDIS units.

HUB-3000

EC-3000 HUB-100 EC-3000


(ECDIS) (ECDIS)

Hardware switch

Autopilot

For example, ECD002 is the primary ECDIS and ECD003 is secondary ECDIS. Then,
to set the primary and secondary ECDIS units, do as follows.

1. See section 1.6.3 to set the HCS for ECD002 and ECD003.
2. Click [TCS] on the tab bar, and then set [Primary] and [Secondary] as shown be-
low.
Setting Option Remarks
Primary ECD002
ECDIS
Secondary ECD003
Manufacturer Enter the manufacturer of the autopilot.
Autopilot
Model Enter the type of the connected autopilot.

3. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
After rebooting the system, the [TCS] button appears on the InstantAccess bar™
of ECD002 and ECD003. The [TCS] button on the ECDIS not selected as primary
ECDIS becomes inoperative (grayed out).
4. To switch the primary and secondary, switch from ECD002 to ECD003 with the
hardware switch and then click the radio button on the [TCS] menu of the ECDIS
menu.
The ECDIS checked at the TCS menu can engage the TCS.
Note: DO NOT switch ECDIS units while the TCS is engaged. Stop the TCS, then
switch the unit.

Off Course Limit
Start: 15.0
Alert Threshold: 30.0
MIN Maneuvering Speed: 4.0 kn

1-50
1. INITIAL SETTING AND ADJUSTMENT

1.6.5 Detail settings for the TCS


You can set the detail settings for the TCS on the [Detail Setting] window of the [TCS]
menu.

Parameter Explanation
Rules Enable Heading Monitor Uncheck this item.
Off Course Limit Start Course difference limit to start the TCS
Alert Threshold Course difference alert threshold
Join Track*1 Min XTE When the XTE value exceed this value, return to
the course.
Min Course Error When the course difference value exceed this val-
ue, return to the course.
Default Approach Angle Preferred angle at which to approach track center-
line
Radius Preferred radius of turns
Advance Coefficient Tuning parameter, must be set greater than "1.0".
Delay Delay between the TCS start and start of the ma-
neuver
Ramp Time Duration of the smoothing of XTE values that are
sent to autopilot at TCS start
Monitoring XTE at Pivot point Check the checkbox to change the reference point
for the XTE from CCRP to pivot point.
Alert Talker ID Keep the default setting.
Track Control Rudder Limit - Line/Turn Rudder limit value sent to autopilot.
XTE Noise - Line/Turn White noise added to XTE values. Normally, set to
“0”. Adjust the value in cases where autopilot tun-
ing is incorrect.
Open Sea - Deadband -
Edge Width
Open Sea - Deadband -
Rate of Change
Keep the default setting.
Open Sea - Course Adjust -
Min XTE
Open Sea - Course Adjust -
Target Distance

1-51
1. INITIAL SETTING AND ADJUSTMENT

Parameter Explanation
Track Control XTE Gain - Open Sea* 2 Adjust the gain for the XTE. To adjust the gain val-
ue manually, activate the checkbox for [Manual]
XTE Gain - All Waters*2 and enter the setting value.
Alert Talker ID Keep the default setting.
Track Pilot Talker ID Select “EI” to use autopilot NP-5400. Select “II” for
all other autopilots.
No Start Period Before The TCS is unavailable when the time to the WOP
Turn*3 (Wheel Over Point) is shorter than the setting val-
ue here.
Use Advance Values from Check the checkbox to use PT-900.
Autopilot • Checked: Use the forwarding distance set at
autopilot.
• Unchecked: Use the forwarding distance set at
ECDIS.
Curved EBL*4 End Tolerance Keep the default setting.
Length Adjust the forwarding distance for the curved EBL.
Program Track*4 Max ROT at Start Starting PT is disabled if ROT exceeds this limit.
Warning Escala- Change to Alarm Check to have the alert priority change from Warn-
tion ing to Alarm when the alert 150 "Early Course
Change Indication" is not acknowledged while the
TCS is not engaged. If not checked the priority re-
mains at Warning and the alert is re-generated.
Interval Sets both the time to wait until the alert priority is
changed from Warning to Alarm and time wait until
the alert is re-generated.
Course Change Early Course Change Threshold value for the alert 150 "Early Course
Alert Timing Change Indication".
Approach Alarm Threshold value for the alert 151 "Actual Course
Change Indication".

*1: Parameters effect correcting the XTE. They are available for GoAW mode of PT-
500A and FAP-2000.
*2: Parameters are available for PT-500, PR-6000 and PR-9000.
*3: Parameters are available for PR-6000, PR-9000 and NP-5400.
*4: Parameters are available for FAP-2000 and FAP-3000.

1-52
1. INITIAL SETTING AND ADJUSTMENT

1.6.6 [Filter Setting] window


The tolerance used for the sensor’s integrity check is set on the [Filter Setting] window.
When the difference between pairs of sensors is higher the tolerance value, integrity
check result becomes [Failed] or [Doubtful]. Normally, it is not required to change the
tolerance. If [Failed] or [Doubtful] appear frequently, adjust the value.

1.6.7 [Other Setting] window


Select the data format for the route data created at the FMD-3u00 on the [Other Set-
ting] window. The route data can be output to the external equipment (GP-170 etc).

Menu item Description


[Input Route Data Select the input method for route data received from other equip-
Setting] ment.
• [None]: Route data from other equipment is not used.
• [File (HTTP)]: Uses data uploaded via the HTTP protocol. The
connected equipment must support the EC-3000's upload func-
tion.
Note 1: After changing this setting, reboot the system to apply the
setting.
Note 2: Do not select [File (HTTP)] when the manufacturer does
not sign the non-disclosure agreement with FURUNO. Detailed
specification depends on the disclosed information between FU-
RUNO and manufacturer.
[Output Route Select the route data format.
Data Setting] • [File and RMB]: Output the route data with the file format and
RMB sentence. The LAN connection with the external equip-
ment is required.
• [RTE and WPL]: Output the route data with the RTE and WPL
sentences. The serial connection with the external equipment is
required.

1-53
1. INITIAL SETTING AND ADJUSTMENT

Menu item Description


[Output Route File Select whether the channel limit is symmetrical or asymmetrical.
Format] This setting is available when [Output Route Data Setting] is set to
[File and RMB].
• [Symmetrical]: The channel limit is symmetrical.
• [Asymmetrical]: The channel limit is asymmetrical.
[Source SFID] Select the additional SFID when CCRS outputs the sentence from
the TCS ([ECDIS SFID] or [TCS SFID]).

1.7 [AMS] Menu


The AMS menu sets up the interface between the AMS (Alert Management System)
and the processor unit, including the AMS operating mode.

Note 1: For Chart Radars, only the settings on the [Operation Mode Setting] window
are required (see section 1.7.1).
Note 2: For how to set the alert definition of AMS, see the FURUNO information.

1.7.1 AMS mode operation


1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Operation Mode Setting] on the menu bar.

item Remarks
[Alert Monitoring In- Set the time to wait before clearing the corresponding alert when
terval] communication with a sensor is interrupted.
[Disable Alert Time- Select the units where the alert is not to be cleared.
out Clear] (01 to 05)
[Output Data Type Select the data type of alert notification, ALR or ALF.
For INS]
[Enable Category A Select if the alert buzzer sounds when the alert of Category A oc-
Buzzer] curs.
[Buzzer Pattern] Sets the buzzer sound pattern to output when an alert occurs.
[INS]:
• Alert priority = “Alarm”: Three short beeps, four seconds mute,
then repeat.
• Alert priority = “Warning”: Two short beeps, four seconds
mute, then repeat.
[Legacy]:
• Alert priority = “Alarm” or “Warning”: Alarm sounds continuous-
ly.

1-54
1. INITIAL SETTING AND ADJUSTMENT

item Remarks
[Transfer Category] Check the checkbox of the appropriate Category (A to C) to
(A~C) transfer the alerts.
[Stop Transfer Cate- Select [YES] to enable stopping of the alert transfer for Category
gory A ACK] A alerts by ACK operation. In this case, the alert is not acknowl-
edged.
[Transfer Alerts to Set the permissions for the alert transmission to BNWAS (Bridge
BNWAS] Navigational Watch Alarm System). The unit(s) checked here are
allowed to output the alert signal to the BNWAS.
• [MFD]: Multifunction Display
• [ECD]: ECDIS
• [RAD]: Radar
• [CRA]: Chart Radar

3. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.7.2 Master/Backup AMS setting


Set the master and backup AMS among the processor units connected to AMS. The
master AMS outputs the alert data to the external AMS. When communication with the
master AMS is lost, the backup AMS outputs the alert data to the external AMS in-
stead of the master AMS.

Follow the procedure below to set master and backup AMS.

1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [AMS Main/Backup Setting] on the menu bar.

3. Select the Equipment ID from the pull-down list for [AMS Main] to assign the mas-
ter AMS.
4. Select the Equipment ID from the pull-down list for [AMS Backup] to assign the
backup AMS.
A maximum of four processor units can be assigned as the backup AMS. The top-
most entry has the highest priority.
5. Select the communication check interval for the master AMS from the pull-down
list for [Alive Check Interval].
6. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-55
1. INITIAL SETTING AND ADJUSTMENT

1.7.3 Alert transfer setting


1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Alert Transfer Setting] o [IAS Setting] on the menu bar.
You can create the alert group and transfer the alert to the navigational equip-
ment. A maximum of ten alert groups ([Group001] to [Group010]) can be created,
and a maximum of 99 alerts can be registered to one alert group.

Alert registration field

3. Select the appropriate alert group number ([Group001] to [Group010]) to transfer,


then set the following items.
Item Remarks
[Event Transmission] Select the alert to be transferred.
• [Change Status Alert]: Transfer the alert whose status is
changed. For example, when alert problem is rectified and
alert status is changed from unrectified to rectified, alert is
transferred.
• [all target Alerts]: All alerts in the group are transferred.
[Fixed Transmission] Select the alert to be transferred periodically.
• [all target Alerts]: All alerts in the group are transferred period-
ically.
• [send “all occurred Alerts” or “ALR <null>, V,V”]: Transfer only
active alert periodically.
[Periodic Interval (1 - Set the interval to transfer the alert data.
60 sec)]
[Sentence] Select the data type of alert notification, ALR or ALF.
[Output 01(02)] Select Equipment ID of the destination equipment to transfer the
alert data. A maximum of two equipments can be assigned to the
destination.

1-56
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[ ] button Opens the [Alert No.Setting] di-
alog box to register the alert to
the group. Select the alert
source equipment from the
[Equipment ID] pull-down list.
Activate the radio button of the
appropriate alert(s), then [OK]
button to register the alert. The
right figure is the example when
alert notification sentence is
ALF. The alert notification sen-
tence is dependent on the specification of the equipment con-
nected to this ECDIS. After clicking the [OK] button, Equipment
ID, alert no. and alert description appear in the alert registration
field.

4. Select [Alert Transfer Setting] and [Backup Navigator Setting] on the menu bar.

5. Set the following items.


Item Remarks
[Transfer Alerts] Select [YES] to transfer the alert to the backup navigator equip-
ment when an alarm is not acknowledged for 30 seconds.
[Output] Select the backup navigator equipment to be used for alert data
transfer.
[Anschutz AP] See section 5.7.
[Alert No.]

6. Select [VDR Setting] on the menu bar.

7. Set the following items.


Item Remarks
[Transfer Alerts] Select [YES] to transfer the alert to VDR.
[Output] Select the VDR to be used for alert data transfer.

8. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-57
1. INITIAL SETTING AND ADJUSTMENT

1.7.4 Other setting window


This section provides a description for the contents of the [Other Setting] window.
Open the [AMS] menu and select [Other Setting] on the menu bar, then select an ap-
propriate setting item.

Item Remarks
[Category C Silence Set the alert silence time for Category C alerts and register
Setting] alerts. A maximum of ten groups ([Group001] to [Group010]) can
be created, and a maximum of six alerts can be registered to one
group. Different alert silence time can be set for each group.

Alert registration field

• [Timer]: Set the time for which the alert is silent. Aural alerts
are not generated during the time set here (setting range: 1 to
300 sec).
• [ ] button: Opens the [Alert No.Setting] dialog box to reg-
ister an alert to a group. For how to register the alert on the
[Alert No.Setting] dialog box, see page 1-57. After registering
the alert, Equipment ID, alert no. and alert name appear on
the alert registration field.
Note: The text in the alert registration field is changed to red
when registered alert is not Category C or the alert is regis-
tered to the other group.
[BR-2000 Connec- Set this item when a FEA-21u7 is replaced with a FMD-3u00 and
tion Setting] the BR-2000 is connected to the FMD-3u00. Set the FMD-3u00
with the same setting selected in [Message Type] in the [Alarm
Inputs+Outputs/AMWSS] dialog box of the FEA-21u7. When a
BR-2000 is not installed, select [Not Connected].
Note: When you use the BR-2000, connect the BR-2000 to the
serial port of the EC-3000 directly. If the BR-2000 is connected
through the Sensor Adapter, the BR-2000 cannot output data.
[ACK Send/Receive Set the options for the alert ACK signal.
Setting] [Send Setting]
• [ACK Type]: Select the sentence to use when transmitting the
alert ACK signal (ACN, ACM, ACN/ACM).
• [Periodic Interval ACK sentence]: Select the transmission in-
terval for the alert ACK signal.
[Receive Setting]
• [Monitoring Interval]: Keep the default setting.
[Silence Time Set- Set the time for which the alert is silent. Aural alerts are not gen-
ting] erated during the time set here.
[Responsibility Keep the default setting.
Transfer Setting]
[Alert Managed Log Keep the default setting.
Setting]
[Change Active Alert Select [YES] to switch to the [ACTIVE ALERT] window automat-
Setting] ically when a new alert occurs.

1-58
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[Enable Silence But- Keep the default setting.
ton Setting]
[Redraw Interval Set- Keep the default setting.
ting]
[Unknown Alert Noti- Keep the default setting.
fy Setting]
[HBT Sentence Set- Set the options for the HBT sentence.
ting] [Send Setting]
• [Periodic Interval]: Set the transmission interval for the HBT
sentence.
• [Broadcast]: Select [YES] to transmit the HBT sentence to all
equipment in the same network.
[Receive Setting]
• [Timeout Count]: Communication lost alert occurs when HBT
sentence is not received after the time set here.
• [Additional Time]: Set a time “gap” from the [Timeout Count]
setting to when the communication lost alert is actually sent.
[FELCOM-18 ACK Select the item according to [Transmission Group Setting] of
Port Setting] FELCOM18. For how to set [Transmission Group Setting] of
FELCOM18, see the installation manual of FELCOM18.
• [MISC (60001)]: Select when [Transmission Group Setting] of
FELCOM18 is set [MISC].
• [Depend on Talker]: Select when [Transmission Group Set-
ting] of FELCOM18 is set [RCOM].

1.7.5 How to import and export [AMS] menu settings


You can import and export the [AMS] menu settings.

Import the [AMS] menu settings


1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Import Alert Configuration] on the menu bar.

3. Click the [Select File] button, then select the setting file to import.
After selecting the setting file, the check result of the setting file appears at [Vali-
dation] field. When the check result is “OK”, the [Import] button is available.
4. Click the [Import] button to import the setting file.
5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-59
1. INITIAL SETTING AND ADJUSTMENT

Export the [AMS] menu settings


1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Export Alert Configuration] on the menu bar.

3. Click the [Export File] button to export the setting file.

1.8 [Alert Define List] Menu


This [Alert Define List] menu sets the alert group and the alert definition.

1.8.1 Alert Group Setting


1. Access the [Common Installation Setting] menu and click [Alert Define List] on the
tab bar.
2. Click [Alert Group Setting] on the menu bar.
The list of the alert groups is shown on the [Alert Group Setting] window.

Item Remarks
1 [Sort by] Select the order to show the alert group.
• [Group No.]: Sorted by the alert group number in ascending or-
der.
• [Priority/Category]: Sorted by the alert priority (Alarm/Warning/
Caution) and category (A to C).
• [Group Text]: Sorted by the [Group Text] column in alphabetical
order.

1-60
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
2 [New Group] Add a new alert group. See section 1.8.2.
button
3 [Delete Delete an alert group. See section 1.8.4.
Group] button
4 All extension Click to open/close the detail setting window for all groups ([+]:
button Open all groups, [-]: Close all groups).
5 [+]/[-] button Click to open/close the detail setting window for the selected
group ([+]: Open, [-]: Close).
6 [Group No.] Group number
7 [Priority] The priority of the alert group (Alarm/Warning/Caution). The prior-
ity of all grouped alerts is the same.
8 [Category] The category of the alert group (A to C). The category of all
grouped alerts is the same.
9 [Group Text] Text shown on the display when an alert in an alert group occurs.
The number in “< >” means the number of alerts.
10 [Details] but- Change the settings for the alert group. See section 1.8.3.
ton
11 [Type No.]* The equipment type which generates the alert.
12 [Data Type]* The alert sentence format (ALF or ALR). This is dependent on the
equipment connected to this system.
13 [Alert No.]* Alert number.
14 [Alert Name]* Alert Name.
15 [+]/[-] button Click to open/close the alert instance data ([+]: Open, [-]: Close).
(ALF) This appears only when the alert sentence is ALF format.
16 Instance Show/Close the instance data.
data* • [Instance ID]: The instance ID of the alert
• [Alert Description]: Contents of the alert instance.
17 [Import] Import the specified group setting.
button
18 [Export] Export the specified group setting.
button

*: The columns are empty or in red for any of the following cases.
• An alert which is preset in another alert group.
• An alert which is not included in the alert definition.
• An ALR sentence is assigned an ALF alert number.
• The Priority or Category of the alert is different from the ones of the group.

3. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-61
1. INITIAL SETTING AND ADJUSTMENT

1.8.2 How to add an alert group


An alert group can be added newly. The maximum number of alert groups is 1,000.

1. Click the [New Group] on the [Alert


Group Setting] window referring to the
figure in step 2 of section 1.8.1. The
[New Group] window is shown.
Note: When 1,000 alert groups have
already been registered, the mes-
sage "Too many groups. Please de-
lete group" is shown. If this occurs,
delete any alert group to make space
for new alert group.

2. Set the options referring to the table shown below.


Item Remarks
[Group No.] Set the alert group number.
[Group Text] Enter the text (max. 64 characters) to show on the display
when an alert included in this alert group occurs.
[Priority] The priority of the alert group (Alarm/Warning/Caution). The
priority of all grouped alerts is the same.
[Category] The category of the alert group (A to C). The category of all
grouped alerts is the same.
[Detailed Information] Set the detail information (max. 1023 characters) for the alert
group.

3. From the [Type No.] pull-down list in the [Alert Setting] window, select the equip-
ment that handles the alert that you want to register in this group.The alert list ap-
pearance depends on the external equipment's sentence format.
For ALR sentence

Checkbox

For ALF sentence [+]/[-] button

Instance
Checkbox data

4. Check the checkbox of the alert to be set in the alert group (multiple selection pos-
sible).
Note: To unregister all alerts from the alert group, click the [Remove All Alert] but-
ton (see the figure in step 1.).
5. Click the [OK] button to close the [New Group] window.

1-62
1. INITIAL SETTING AND ADJUSTMENT

6. To set alerts for other equipment, click the [Details] button of the added alert group
(see the figure in step 2 of section 1.8.1.). The [Group Details] window is shown.
7. Set the alert to the alert group with the same procedure as step 3 to step 5.
8. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.8.3 How to edit an alert group


1. Click the [Details] button of the alert
group to edit on the [Alert Group Set-
ting] window, referring to the figure in
step 2 of section 1.8.1. The [Group
Details] window is shown.

2. Set the appropriate items in the [Group Setting] column referring to the step 2 of
section 1.8.2.
3. Select the alert to add in the alert group referring to the step 3 to step 4of
section 1.8.2.
4. Click the [OK] button to close the [Group Details] window.
5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.8.4 How to delete an alert group


1. Click the [Delete Group] button on the [Alert Group Setting] window, referring to
the figure in step 2 of section 1.8.1. The list of the alert groups is shown in the
[Group Details] window.

Delete All
box

Checkbox

2. Check the checkbox of the alert group to delete. To delete all groups, check the
“Delete All” box.
3. Click the [OK] button.
4. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.8.5 Alert Definition setting for each equipment


You can create alert definitions and activate/deactivate the alert(s) for each external
equipment or sensor.

1. Access the [Common Installation Setting] menu, then select [Alert Define List] on
the tab bar.

1-63
1. INITIAL SETTING AND ADJUSTMENT

2. Select the appropriate equipment type on the menu bar. For example, select [EC-
DIS] o [FMD-3200|3300] to set the alert definitions for FMD-3200/FMD-3300.
Note: The equipment and sensors shown on the menu bar depend on the [Instal-
lation Parameters] menu settings.

3. Set the appropriate options referring to the table shown below.


Item Remarks
1 Equipment type Selected equipment type.
2 [Source] Define the source category to which the alert is assigned for
display in the AMS mode's alert list window ([Navigation],
[Communication] or [External]).
3 [Data Type] Alert sentence format (ALF or ALR). For sensors, select the
alert notification sentence from the pull-down list.
4 [New Alert] button Add a new alert definition. See section 1.8.6.
5 [Delete Alert] but- Delete the alert definition. See section 1.8.8.
ton
6 Alert extension • [+]/[–]: Click to open/close all alerts ([+]: Open, [-]: Close).
button/ This appears when the alert notification sentence is ALF.
All selection • Check the checkbox to select all alert instances. This ap-
checkbox pears when the alert notification sentence is ALF.
7 Separate change • [+]/[–]: Click to open/close the detail window for the alert
button ([+]: Open, [-]: Close).
• Check the checkbox to select the alert, and all instances
are selected for ALF sentence. This only appears when
the alert notification sentence is ALF.
8 Switching check- Show all instances or show only valid state instances. This
box (for alert in- only appears when the alert notification sentence is ALF.
stance) • [ ]: Show the data for all instances.
• [ ]: Show the data for activated instances.
9 Checkbox to acti- Check the checkbox to activate the alert.
vate/deactivate
10 [Alert No.] (ALR) Alert number
[Alert ID] (ALF)
11 [Instance ID] Instance number. This appears when the alert notification
sentence is ALF.
12 [Alert Name] Alert name (editing possible)
(ALR)
[Alert Description]
(ALF)
13 [Priority] The priority of the alert group (Alarm/Warning/Caution), pos-
sible to edit.
14 [Category] The category of the alert group (A to C), possible to edit.
15 [Input Unit] The unit which input the alert.

1-64
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
16 [Details] button Show the detail window for the alert. See section 1.8.7.
17 [Edit] button Edit the alert number. This appears when the alert notifica-
tion sentence is ALF.
18 [Import] button Import the alert definition for currently displayed equipment.
19 [Export] button Export the alert definition for currently displayed equipment.

4. Select the appropriate equipment on the menu bar to activate the alert for each
equipment. For example, the alert number “153” can be activated for No.1 ECDIS
and deactivated for No.2 ECDIS. The following figure is the sample when the No.1
ECDIS is selected. The alerts are listed based on the alert definition of the equip-
ment.

5. Check the checkbox of the alert to activate.


6. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.8.6 How to add an alert definition


An alert definition can be added newly. The maximum number of alert definition is
1,000.

1. Click the [New Alert] button on the alert


definition window referring to the figure
in step 2 of section 1.8.5. The [New
Alert] window is shown.
Note: The 1,000 alert definitions have
been registered, the message "Too
many alert. Please delete any alert." is
shown. If this occurs, delete any alert
definition to make space for the new
alert definition.

2. Set the options referring to the table shown below.


Item Remarks
[Alert Name] (ALR) Enter the alert name (max. 64 characters).
[Alert Description] (ALF)
[Alert ID] (For ALF) Enter the alert number for the ALF sentence.
[Instance ID] (For ALF) Enter the Instance ID.
[Internal Notify No.] Enter the notify number of processor unit. For sensors, this
is automatically numbered.

1-65
1. INITIAL SETTING AND ADJUSTMENT

Item Remarks
[Input Unit] Select the input source for the alert.
• For other than sensors: [Internal], [Digital]
• For sensors: [CCRS], [Digital], [MODBUS]
[Is Active] Activate/Deactivate the alert. [YES]: activated, [NO]: deacti-
vated.
[Priority] The priority of the alert group ([Emergency]/[Alarm]/[Warn-
ing]/[Caution]).
[Category] The category of the alert group (A to C).
[Emergency Icon] Select the icon for the emergency alert. Available only for
alerts with [Priority] set to [Emergency].
[Emergency Buzzer] Select the buzzer sound for the emergency alert. Available
only for alerts with [Priority] set to [Emergency].
[Escalation Mode] Select the priority that escalates the status of an alert,
[Alarm] or [Warning]. Available only for alerts with [Priority]
set to [Warning].
• [Alarm]: When the alert is left unacknowledged, the priority
is changed to [Alarm].
• [Warning]: When the alert is left unacknowledged, the pri-
ority remains as [Warning]. Then, the alert buzzer sounds
again.
[Escalation Time] Set the time to wait before activating the escalation function
against an alert. Available only for alerts with [Priority] set to
[Warning].
[Escalation Transfer] Enable or disable transfer of an Alarm priority alert in the
transfer escalation mode. Available only for alerts with [Es-
calation Mode] set to [Alarm].
[Transfer Time] Set the time to wait before transferring an Alarm priority alert
in the transfer escalation mode. Available only for alerts with
[Escalation Mode] set to [Alarm].
[Integrated Alert] Keep the default setting.
[Send VDR] Select [YES] to transfer the ALR sentence to the VDR.
[Clear Non-Ack Alert Select [YES] to delete the non-acknowledged alerts auto-
when Rectified] matically when they are rectified.
[Detailed Information] Enter the detail information (max. 1023 characters) of the
alert.

3. Click the [OK] button to close the [New Alert] window.


4. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1-66
1. INITIAL SETTING AND ADJUSTMENT

1.8.7 How to edit an alert definition


1. Click the [Details] button on the alert defi-
nition window of equipment type, refer-
ring to the figure in step 2 of
section 1.8.5. The [Alert Details] window
is shown.

2. Edit the options referring to step 2 of section 1.8.6.


3. Click the [OK] button to close the [Alert Details] window.
4. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.8.8 How to delete an alert definition


1. Click the [Delete Alert] button on the alert definition window of equipment type, re-
ferring to the figure in step 2 of section 1.8.5. The [Delete Alert] window is shown.

Select all
checkbox

2. Check the checkbox to delete the alert. If all alerts are deleted, check the “Select
all” checkbox.
3. Click the [OK] button.
4. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.

1.9 [Data Sharing] Menu


The [Data Sharing] menu is has no use.

1-67
1. INITIAL SETTING AND ADJUSTMENT

1.10 [Save and Sync] Menu


After completing the settings on the [Own Ship Setting], [Installation Parameters],
[CCRS], [TCS], [AMS] and [Alert Define List] menus, confirm the consistency of the
configuration and save it on this menu. By saving the configuration, the configuration
data can be copied to other processor units connected to the network. The configura-
tion data can be saved to a medium and loaded to a processor unit.

1.10.1 Consistency check and save the configuration


1. Access the [Common Installation Setting] menu and click [Save and Sync] on the
tab bar.

2. Click [Consistency Check] to confirm the consistency of the setting.


When the consistency check is completed, the result of the check is shown.
If an inconsistency is detected, an error message appears. You can not save the
configuration until the inconsistency is corrected. Check the setting and correct
the inconsistency, then perform the consistency check again.
3. When the message "Check consistency completed, you can save data. Please
push the "Save" button" is shown, click [Save] in the info bar.
The pop-up message shown below appears.

4. Click [OK] to save the configuration.


If other processor units and Sensor Adapters are connected to the network, the
confirmation message shown below appears. The message does not appear if a
unit in the network is not powered. Click [OK] to save the configuration.

Note 1: After saving the configuration, an Equipment ID that could not save the
configuration correctly may appear in the [Synchronous failure] window. In this
case, click the [OK] button, then retry [Save].

1-68
1. INITIAL SETTING AND ADJUSTMENT

Note 2: If you did the consistency check and save after entering settings on [Own
Ship Setting], reboot the unit.
5. After saving the configuration, confirm that the Equipment ID of all units are cor-
rect.
• Processor unit EC-3000
Check the Equipment ID of processor unit as shown below.
1) Click the [?] button on the status bar.

2) Click [About].
3) Check [Equipment ID] on the [System1] tab.

Example: [System 1] tab for ECDIS


• Radar processor unit and Sensor Adapter
If the Equipment ID of the radar processor unit or Sensor Adapter is not correct,
the alert shown below appears.
Radar processor unit: "Radar Processor COM Error"
Sensor Adapter: "Sensor Adapter * COM Timeout" (* = 1 to 16)
If the Equipment ID is not correct, set the Equipment ID on the [Basic Setting]
menu (see section 1.2). At this time, turn off all units except the unit to be set, or
disconnect all LAN cables except the cable for PC.

1-69
1. INITIAL SETTING AND ADJUSTMENT

1.10.2 How to save the configuration data to a medium


You can save the configuration data to a medium (PC, USB memory, etc.). Set the
medium and then do as follows:

1. Click [Export] at the upper right of the [Save and Sync] menu.

Click [Export].

The window shown below appears.

2. Select the configuration data type that you want to save, and then click [OK].
• [Sensor Setting]: Configuration data on the [Own Ship Setting], [Installation Pa-
rameters] and [CCRS] menu.
• [TCS Setting]: Configuration data on the [TCS] menu (ECDIS only).
• [AMS Setting]: Configuration data on the [AMS] menu.
• [Alert Setting]: Configuration data on the [Alert Define List] menu.
3. Select where to save the configuration data.
The file name "SettingFiles.tar" is created.

1.10.3 How to load the configuration data


You can load the configuration data from a medium (PC, USB memory, etc.). Set the
medium and then do as follows:

1. Click [Import] at the upper right of the [Save and Sync] menu.

Click [Import].

2. Select the configuration data file ("SettingFiles.tar").


3. Select the configuration data type that you want to load, and then click [OK].
• [Sensor Setting]: Configuration data on the [Own Ship Setting], [Installation Pa-
rameters] and [CCRS] menu.
• [TCS Setting]: Configuration data on the [TCS] menu (ECDIS only).
• [AMS Setting]: Configuration data on the [AMS] menu.
• [Alert Setting]: Configuration data on the [Alert Define List] menu.
4. After loading the data, perform the consistency check and save the configuration
data on the [Save and Sync] menu.

1-70
1. INITIAL SETTING AND ADJUSTMENT

1.11 [System Monitor] Menu

9876-xxxx

GPS
Sync
0

This menu displays system information of units as shown below.

• Processor unit (EC-3000)


• Monitor (Furuno make only)
• Control unit
• Radar processor unit
• Sensor Adapter
Click [System Log] to save the log data to a medium (PC, USB memory, etc).

1-71
1. INITIAL SETTING AND ADJUSTMENT

1.12 [Software Update] Menu


Update the software of the processor unit EC-3000, radar processor unit RPU-013,
and control unit RCU-024/025/026 on the [Software Update] menu. For the update of
the Sensor Adapter, see section 2.3.

Note: To update the software with the update file, access the [Common Installation
Setting] menu via LAN connection. To update the software with the DVD, access the
[Common Installation Setting] menu with the control unit.

xx.xx.xxxx
xx.xx.xxxx

xx.xx.xxxx
xx.xx.xxxx

xx.xx.xxxx
xx.xx.xxxx

1. For LAN connection, connect the USB memory which has the update file to the
PC connected via LAN. For access with the control unit, insert the update DVD in
the processor unit's DVD drive.
2. Access the [Common Installation Setting] menu and click [Software Update] on
the tab bar.
For the IP address of the unit to update, see the Equipment ID list at the back of
this manual.
3. Select the unit to update from the menu bar.
4. Click [Select File] to select the update, and then click [OK].
The current software version and updated software version are displayed.
5. Check the checkbox for the software to update.
6. Click [Update Software]. A confirmation message appears.

7. Click [OK] to update the software.


The progress bar shows the update progress. After completing the update, the
system is automatically rebooted.
8. If connected to the gateway network, the link is shown on the display after com-
pleting the system reboot. Click the link on the display to access the [Common In-
stallation Setting] menu.
If connected to the sensor network, enter the IP address of the sensor network
to access the [Common Installation Setting] menu after completing the system re-
boot.

1-72
1. INITIAL SETTING AND ADJUSTMENT

1.13 [Factory Test & Default] Menu


The [Factory Test & Default] menu does the factory test to check operation and re-
stores the system default settings.

Factory Test
Click [Start] to perform the factory test. The result of the test is shown on the display.

The result of the test is shown in this area.

If "NG" appears, confirm the state of the unit on the [System Monitor] menu.

Factory Default
The factory default function restores all factory defaults (except the settings on the
[Basic Setting] menu). In the default arrangement all processor units powered in the
network are restored to default condition. To restore only the settings of the processor
unit, disconnect the LAN connector from the LAN1 port of the processor unit before
restoring the factory defaults.

Note: The route and user chart data are not deleted when the factory default function
is performed on the [Factory Test & Default] menu.
1. Click [Reset to Factory Default]. The following message appears on the screen.

2. Click [OK] to restore the system to the default setting.


The progress bar shows update progress. When the restoration is completed, the
system is automatically rebooted.
3. If connected to the gateway network, the link is shown on the display after com-
pleting the system reboot. Click the link on the display to access the [Common In-
stallation Setting] menu.
If connected to the sensor network, enter the IP address of the sensor network
to access the [Common Installation Setting] menu after completing the system re-
boot.

1-73
1. INITIAL SETTING AND ADJUSTMENT

Note: When you restore the Chart Radar default, the initialization of the radar proces-
sor unit needs more time than the processor unit. After completing the system reboot
of the processor unit, wait for about one minute until the system reboot is completed,
and the communication between processor unit and radar processor unit is estab-
lished. If the communication is not established, the alert "Radar Processor COM Error"
appears and the [Antenna] button at the upper left of the display shows "NO RADAR".
Do not use the unit until the alert is resolved and the [Antenna] button shows the cur-
rent antenna selection (example: ANT-1(M)).

1.14 [Conning] Menu


The [Conning] menu configures the layout and data to show on the conning display.

Menu item Explanation


Items on the menu bar
[Conning (3x6)] Consists of 18 blocks (3x6). Six sets of conning layout sheet can
be prepared [Sheet 1] to [Sheet 6].
[Wide Conning (4x6)] Consists of 24 blocks (4x6). Six sets of conning layout sheet can
be prepared [Sheet 1] to [Sheet 6].
Note: The wide conning display is available with the wide moni-
tor.
[Side Conning (1x9)] Consists of 9 blocks (1x9). Four sets of conning layout sheet can
be prepared [Sheet 1] to [Sheet 4].
Note 1: The side conning display is available with the wide mon-
itor in the radar mode.
Note 2: For the FMD-3u00, see "How to display the side conning
display (ECDIS only)" on page 1-75 to use the side conning dis-
play in the radar mode.
[Mini Conning (1x5)] Consists of 5 blocks (1x5).
[Save/Import/Export] You can save the conning display data to a medium and load it
on the network.
[Decoder Define Im- No use.
port/Export]
[Decoder Import/Ex- No use.
port]

1-74
1. INITIAL SETTING AND ADJUSTMENT

Menu item Explanation


Items in the view area
[Name] Enter the name of the sheet displayed on the view area. The
sheet name entered here appears on the status bar of the con-
ning display.
[Show] Check the checkbox to show the sheet name on the status bar
of the conning display.
[Copy From] Copy a conning layout sheet to another sheet.
[Components] Select the components to show on the conning display. The
components are available in three sizes: [Small], [Medium],
[Large]. The [Small] components occupy one block. The [Medi-
um] components occupy two blocks. The [Large] components
occupy three or more blocks. Check the size of the component
to show on the [Components] window. Select the component
and click it to show the component on the [Layout] window.
[Layout] You can configure the layout and data to show on the conning
display. Drag and drop the components to configure the layout.
Click to delete a component from the [Layout] window. To se-
lect the data source for a component, click to display the
advanced settings window. See the procedure on
section 1.14.1.

Conning layout sheet and useable monitor

Layout Sheet Monitor


Conning (3x6) MU-190, MU-231, MU-201 CE, JH 19T14FUD, JH 20T17FUD,
JH 23T12FUD, JH 23T14FUD, HD 19T21MMD
Wide Conning (4x6) MU-270W, JH 26T11MMD, HD 24T21MMD, HD 24T22FUD,
Side Conning (1x9) HD 26T21MMD, HD 26T22MMD, HD 26T22FUD, HD 27T22-
FUD, HD 32T22FUD, HD 55T22FUD, NI WA460-01, NI
WA270-01
Mini Conning (1x5) Available with any monitor.

How to display the side conning display (ECDIS only)


To display the side conning display with the FMD-3u00, do as follows:

1. In the chart mode, press Ctrl, Shift and t keys simultaneously on the control unit
or keyboard.
The password input dialog box appears.

2. Enter the password and click [OK].


Note: The service mode remains enabled until you press Ctrl, Shift and t keys
simultaneously or reboot the unit.
3. Click [MENU] to open the menu.

1-75
1. INITIAL SETTING AND ADJUSTMENT

4. Click [Ship & Route Parameter], then open the [Function2] tab.

5. Check the checkbox of [Show Side Conning at Radar mode].


6. Click the [Save] button.

1.14.1 How to select the data source


Click on the advanced settings window (see section 1.14.2.) to display the [Data
Source Select] window. Select the data source in the [Data Source Select] window to
show the respective data on the conning display.

• [Selected Data Source]: This is automatically generated when [Type], [Source] and
[Decoder] are selected.
• [Type]: Select the data source type.
Setting Description
[Digital] Displays contact input data.
[Analog] Displays analog input data.
[NMEA] Displays data received directly from NMEA device.
[Own Ship] Displays Own Ship data received from own ship management program.

• [Source]: Select the sensor from which the data will be sourced.
• [Decoder]: Select which data from the source sensor to use.

1-76
1. INITIAL SETTING AND ADJUSTMENT

1.14.2 Advanced settings window


Note: Do not use the following components:
• CommonMP • Fore & AFT bridge (Wide) Havyard122
• Fore & AFT bridge (Wide) U10662/ • Fore & AFT bridge (Wide) NB802/818/
10683/10782/1340 830/832/857
• Motion Sensor • Nav. Information For GSI
• Steering Mode for GSI

[Small] components (one block)


• [Alert (Current Only)]

• Compass

[Title]: Enter the title of the component.


[Sensor Name Source]: Enter the sensor name.
[Primary Source]: Select the data source of the upper pointer.
[Secondary Source]: Select the data source of the lower pointer.
[Decimal Place]: Check the checkbox to show the value after decimal point.
• Data And Unit Display

[Layout]: Check the checkbox of [Title] to show the title of the component. Check
the checkbox of [Equal interval] to show only numeric data.
[Label]: Enter the data name of [Object 1] to [Object 4]. Example: "Heading",
"Speed", etc.
[Source]: Select the data source of [Object 1] to [Object 4].

1-77
1. INITIAL SETTING AND ADJUSTMENT

[Decimal Place]: Check the checkbox to show the value after decimal point.
Zero Padding: Set the number of decimal points to show "0" in the [Source] for each
object.
[Unit]: Enter the unit.
[5 lines]: Check the checkbox to show 5 lines data on the component.
• Dual Horizontal Bar

[Title]: Enter the title of the component.


[Primary Source]: Select the data source of the bar.
[Secondary Source]: Select the data source of the triangle below the bar.
[Start Value]: Set the minimum value of the bar.
[End Value]: Set the maximum value of the bar.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
[Mirror Vertically]: Check the box to invert the position of the bar and value.
• Empty

[Title]: Enter the title of the component.


• [Final ETA]

[Title]: Enter the title of the component.


• Generator Engine

[Title]: Enter the title of the component.


[Label]: Enter the data name.
[Actual Source]: Select the data source of the actual engine generating power.
[Rated Source]: Select the data source of the rated engine generating power.

1-78
1. INITIAL SETTING AND ADJUSTMENT

• Graph

[Title]: Enter the title of the component.


[Type]: Set the graph type.
• [(2x)Time/Y-graph]: The [Primary (Y1)] and [Secondary (Y2)] are used as Y-coor-
dinate for two independent graphs. The time is used as the X-coordinate for both
graphs.
• [(1x)X/Y-graph]: The [Primary (Y1)] input is used for the X-coordinate and the
[Secondary (Y2)] for the Y-coordinate.

[Label Source]: No use.


[Mode Source]: No use.
[Label]: Enter the title of [Primary (Y1)] and [Secondary (Y2)] graph.
[Source]: Select the data source of [Primary (Y1)] and [Secondary (Y2)].
[Unit]: Set the unit used in [Primary (Y1)] and [Secondary (Y2)] graphs.
[Smoothing]: Select [Apply] to smooth the graph.
[Scale Ň Range]: Set the display range of the Y-coordinate. Three display ranges
can be entered.
[Time Span]: Set the display range of the X-coordinate.
[Sample Interval]: Set the interval of [Primary (Y1)] and [Secondary (Y2)] graph plot.
[Scale Resolution]: Select the scale resolution of the graph.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Decimal Num]: Select the number of digits after decimal point.
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the Y-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.
• Horizontal Bar

[Title]: Enter the title of the component.


[Left Source]: Select the data source of the value shown at the upper left of the bar.
[Center Source]: Select the data source of the value shown above the bar.
[Right Source]: Select the data source of the value shown at the upper right of the
bar.

1-79
1. INITIAL SETTING AND ADJUSTMENT

[Primary Source]: Select the data source of the green bar.


[Secondary Source]: Select the data source of the triangle below the bar.
[Start Value]: Set the minimum value of the bar.
[End Value]: Set the maximum value of the bar.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
[Mirror Vertically]: Check the checkbox to invert the position of the bar and value.
• Horizontal Ruler

[Title]: Enter the title of the component.


[Top Left]: Select the data source of the value shown at the upper left of the bar.
[Top Center]: Select the data source of the value shown above the bar.
[Top Right]: Select the data source of the value shown at the upper right of the bar.
[Bottom Left]: Enter the text shown at the lower left of the bar.
[Bottom Center]: Enter the text shown below the bar.
[Bottom Right]: Enter the text shown at the lower right of the bar.
[Primary Source]: Select the data source of the indication shown with white triangle.
[Secondary Source]: Select the data source of the indication shown with gray trian-
gle.
[Start Value]: Set the minimum value of the bar.
[End Value]: Set the maximum value of the bar.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
• Numeric Data Display

[Title]: Enter the title of the component.

1-80
1. INITIAL SETTING AND ADJUSTMENT

[Source]: Select the data source same as [Object 1] or [Object 2] to show the ab-
breviated name of the data source unit.
[Label]: Enter the data name of [Object 1 (or 2)].
[Limit]: Set the digit number of the data of [Object 1 (or 2)].
[Source]: Select the data source of [Object 1 (or 2)].
[Zero Padding]: Set the number of decimal points to show "0" in the [Source] for
each object.
[Unit]: Set the unit of data for [Object 1 (or 2)].
• Rudder

[Title]: Enter the title of the component.


[Location]: Select the rudder location from the pull-down list.
[Rudder Title]: Enter the title of the [Rudder 1 (or 2)] indicator.
[Primary Source]: Select the data source of the long pointer of [Rudder 1 (or 2)] in-
dicator.
[Secondary Source]: Select the data source of the long pointer of [Rudder 1 (or 2)]
indicator.
[Max Angle]: Set the maximum rudder angle of [Rudder 1 (or 2)] indicator.
[Scale Resolution]: Select the scale resolution.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
• [Stabilizer Status]

[Title]: Enter the title of the component.


[Object1 (to 4)]
[Label]: Enter the data name of [Object 1 (or 2)].
[Source]: Select the data source of [Object 1 (or 2)].
• [Steering Mode]

• Thruster

1-81
1. INITIAL SETTING AND ADJUSTMENT

[Title]: Enter the title of the component.


[Label]: Enter the data name.
[Actual Source]: Select the data source of the actual thruster generating power.
[Rated Source]: Select the data source of the rated thruster generating power.
• Track Order
Track Order
021.8°
1.0 NM
001.0 °/min
GoSEA Appr. Enabled

[Title]: Enter the title of the component.


• Watch Alarm

[Title]: Enter the title of the component.


[Backup Source]: Select the data source of the backup officer name.
[Stage Source (ALR)]: Select the Stage Source (ALR).
[Stage Source (wtr)]: Select the Stage Source (wtr).
[Maximum Time Source]: Select the data source of the watch time setting.
[Remaining Time Source]: Select the data source of the remaining time.
• [Watch Alarm (Multi)]

[Title]: Enter the title of the component.


[Backup Source]: Cannot be changed. Set automatically.
[Stage Source (ALR)]: Select the Stage Source (ALR).
[Stage Source (wtr)]: Select the Stage Source (wtr).
[Maximum Time Source]: Select the Maximum Time Source.
[Remaining Time Source]: Select the Remaining Time Source.

1-82
1. INITIAL SETTING AND ADJUSTMENT

[Medium] component (two blocks.)


• Azimuth Propulsion

[Title]: Enter the title of the component.


Azimuth
[Label]: Enter the data name shown at the bottom of the indicator.
[Source]: Select the data source of the azimuth propulsion.
[Unit]: Enter the unit for the azimuth propulsion.
[North Angle]: Enter the north angle relative to the screen. Normally, enter "0".
[Value Mapping]: When the checkbox is checked, if the input azimuth angle is other
than 0° to 359°, this equipment calculates the input value so that the azimuth angle
is within 0° to 359°. For example, the input azimuth angle is “-90°”, the displayed
value is “270°”. When the checkbox is not checked, this equipment shows the same
value as the input data.
Object
[Label]: Enter the data name of [Object1 (to 4)].
[Source]: Select the data source of the numeric data for [Object1 (to 4)].
[Unit]: Enter the unit for [Object1 (to 4)].
• [Check ETA]

[Title]: Enter the title of the component.

1-83
1. INITIAL SETTING AND ADJUSTMENT

• Command Matrix

[Title]: Enter the title of the component.


[Control Type]: Set the number of columns for the matrix.
[Thruster Num]: Set the number of rows for the matrix.
[Control Type Label]: Enter the text that appears at the top of the matrix.
[Name]: Enter the text that appears at the left side of the matrix.
[Source1] to [Source8]: Set the source for the thruster data for the matrix.
• Dial Meter

[Title]: Enter the title of the component.


[Dial Title]: Enter the text to show above the indicator.
[Primary Source]: Select the data source of the long pointer of the indicator.
[Secondary Source]: Select the data source of the outer pointer of the indicator.
[Peak Source]: Select the data source of the short pointer of the indicator.
[Unit]: Set the unit of the data.
[Start Value]: Set the minimum value of the indicator.
[End Value]: Set the maximum value of the indicator.
[Angle]: Define the extent of the dial.
[Rotation]: It can be rotate the direction of the indicator. Normally, set to "0".
[Scale Resolution]: Select the scale resolution.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.

1-84
1. INITIAL SETTING AND ADJUSTMENT

• Drift And Radius

[Title]: Enter the title of the component.


• Dual Azimuth Promotion

[Title]: Enter the title of the component.


[Location]: Select the position of thruster ([FORE] or [AFT]).
[Title]: Enter the title to show at the top of the indicator.
[Degree]
[Actual]: Set the source of the angle which the needle of the outer periphery points
to (feedback angle of the thruster).
[Order]: Set the source of the angle which the needle of the inner periphery points
to (actual azimuth of the thruster).
[Unit]: Enter the unit of measurement for the azimuth of the thruster.
[RPM]/[MW]/[Lever]
A maximum of three data can be displayed under the indicator.
[Label]: Enter the name of the data shown beneath the analog indicator,
[Source]: Set the source of the data that appears beneath the analog indicator.
[Unit]: Enter the unit for the data that appears beneath the analog indicator.
• Dual Dial Meter

[Title]: Enter the title of the component.

1-85
1. INITIAL SETTING AND ADJUSTMENT

[Dial Title]: Enter the title to show at the top of [Dial Meter 1 (or 2)] indicator.
[Primary Source]: Select the data source of the long pointer of [Dial Meter 1 (or 2)]
indicator.
[Secondary Source]: Select the data source of the outer pointer of [Dial Meter 1 (or
2)] indicator.
[Peak Source]: Select the data source of the short pointer of [Dial Meter 1 (or 2)]
indicator.
[Unit]: Set the unit of the data.
[Start Value]: Set the minimum value of the [Dial Meter 1 (or 2)] indicator.
[End Value]: Set the maximum value of the [Dial Meter 1 (or 2)] indicator.
[Angle]: Define the extent of the dial.
[Rotation]: It can be rotate the direction of the [Dial Meter 1 (or 2)] indicator. Normal-
ly, set to "0".
[Scale Resolution]: Select the scale resolution of [Dial Meter 1 (or 2)] indicator.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
• Generator Engine

[Title]: Enter the title of the component.


[Label]: Enter the data name.
[Actual Source]: Select the data source of the actual engine generating power.
[Rated Source]: Select the data source of the rated engine generating power.
• Generator Engine Bar

[Title]: Enter the title of the component.


[Number of Show]: Set the number of graphs.
[Label]: Enter the text on the upper of the graphs ([Object 1] to [Object 9]).
[Source]: Enter the source of the graphs ([Object 1] to [Object 9]).

1-86
1. INITIAL SETTING AND ADJUSTMENT

[MAX Generate (kW)]: Enter the maximum values of the graphs ([Object 1] to [Ob-
ject 9]).
[Source State]: Set the source that outputs operating status. The green indication
of the graph means the generator is working, the red indication means the generator
has stopped.
• Graph

[Title]: Enter the title of the component.


[Type]: Set the graph type.
• [(2x)Time/Y-graph]: The [Primary (Y1)] and [Secondary (Y2)] are used as Y-co-
ordinate for two independent graphs. The time is used as the X-coordinate for
both graphs.
• [(1x)X/Y-graph]: The [Primary (Y1)] input is used for the X-coordinate and the
[Secondary (Y2)] for the Y-coordinate.

[Label Source]: No use.


[Mode Source]: No use.
[Label]: Enter the title of [Primary (Y1)] and [Secondary (Y2)] graph.
[Source]: Select the data source of [Primary (Y1)] and [Secondary (Y2)].
[Unit]: Set the unit used in [Primary (Y1)] and [Secondary (Y2)] graphs.
[Smoothing]: Select [Apply] to smooth the graph.
[Scale Ň Range]: Set the display range of the Y-coordinate. Three display ranges
can be entered.
[Time Span]: Set the display range of the X-coordinate.
[Sample Interval]: Set the interval of [Primary (Y1)] and [Secondary (Y2)] graph plot.
[Scale Resolution]: Select the scale resolution of the graph.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Secondary (Y2) Scale]: Check the check box to show the value input from the data
source of [Secondary (Y2)].
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the Y-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.

1-87
1. INITIAL SETTING AND ADJUSTMENT

• Graph (Wind Speed & Direction)

[Title]: Enter the title of the component.


[Label]: Enter the title of [Wind Speed] and [Wind Direction].
[Source]: Select the source of [Wind Speed] and [Wind Direction].
[Unit]: Enter the unit of [Wind Speed] and [Wind Direction].
[Smoothing]: Select [Apply] to smooth the graph.
[Scale Ň Range]: Set the display range of the Y-coordinate. Three display ranges
can be entered.
[Time Span]: Set the display range of the X-coordinate.
[Sample Interval]: Set the interval of [Primary (Y1)] and [Secondary (Y2)] graph plot.
[Scale Resolution]: Select the scale resolution of the graph.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Secondary (Y2) Scale]: Check the check box to show the value input from the data
source of [Secondary (Y2)].
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the Y-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.
• Heading

[Compass Title]: Enter the title shown at the top of the compass meter.
[Location]: Select the location of the heading sensor from the pull-down list.
[Compass Sensor Name Source]: Enter the name of the heading sensor.
[Compass Primary Source]: Select the data source of the upper pointer.
[Compass Secondary Source]: Select the data source of the lower pointer.
[Primary Label]: Enter the title for the primary source.
[Ruler Title]: Enter the title of the ruler.
[Ruler Primary Source]: Select the data source of the white triangle pointer.
[Ruler Secondary Source]: Select the data source of the gray triangle pointer.
[Start Value]: Set the minimum value of the bar.
[End Value]: Set the maximum value of the bar.

1-88
1. INITIAL SETTING AND ADJUSTMENT

[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
• Next Leg

• Pitch And Roll

[Title]: Enter the title of the component.


[Location]: Select the reference point for the pitch and roll from the pull-down list.
[Title (Pitch And Roll 1 / Pitch And Roll 2)]: Enter the text shown at the top of [Pitch
And Roll 1 (or 2)] indicator.
[Type]: Select the object to show in the [Pitch And Roll 1 (or 2)]. Setting range: [Roll],
[Pitch].
[Primary Source]: Select the data source of [Pitch And Roll 1 (or 2)] indicator.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
• Position Local Time

[Title]: Enter the title of the component.


[Latitude Label]: Enter the text to show at the left of the latitude value.
[Longitude Label]: Enter the text to show at the left of the longitude value.
[DATUM Label]: Enter the text that indicates the datum.
[Local Time Label]: Enter the text to show at the left of the time information.

1-89
1. INITIAL SETTING AND ADJUSTMENT

[Latitude Source]: Select the data source of the latitude.


[Longitude Source]: Select the data source of the longitude.
[DATUM Source]: Select the data source of the datum.
[Local Time (Time) Source]: Select the data source of the time information.
[Local Time (Date) Source]: Select the data source of the date information.
[Sensor Name Source]: Select the appropriate sensor name source.
• Track Order

[Title]: Enter the title of the component.

• Two Dimension Plotter

[Title]: Enter the title of the component.


[Source (X)]: Select the data source of the X-coordinate value.
[Source (Y)]: Select the data source of the Y-coordinate value.
[Label (Y)]: Enter the title of the Y-coordinate.
[Unit (Y)]: Set the unit of the Y-coordinate.
[Symbol]: Select the plot mark.
[Time Span]: Enter the time span for the plotter screen.
[Sample Interval]: Enter the sample interval for the plotter screen.
[Max Value (X)]: Enter the maximum value of the X-coordinate.
[Max Value (Y)]: Enter the maximum value of the Y-coordinate.
[Axis Point (X)]: Enter the axis point of X-coordinate.
[Axis Point (Y)]: Enter the axis point of Y-coordinate.
[Axis Type]: Select the axis type. [Under Left]: The axis point is located at the under
left of the screen. [Central]: The axis point is located at the center of the screen.
[Tick Label]: Check the checkbox to show the tick label.

1-90
1. INITIAL SETTING AND ADJUSTMENT

• Vertical Bar

[Title]: Enter the title of the component.


[Top Source]: Select the data source for the data at the top of the vertical bar.
[Bottom Source]: Select the data source for the data at the bottom of the vertical bar.
[Primary Source]: Select the data source of the bar.
[Secondary Source]: Select the data source of the triangle indicator.
[Start Value]: Set the minimum value of the bar.
[End Value]: Set the maximum value of the bar.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
[Mirror Horizontally]: Check the checkbox to invert the position of the bar and value
horizontally.
[Average Value]: Check the checkbox to show the average value.
• Vertical Graph (Middle)

[Title]: Enter the title of the component.


[Label Source]: Enter the source of text shown on the right of the graph. Manual in-
put is available.
[Mode Source]: Enter the source of text shown on the right of the value indication.
Manual input is available.
[Label]: Enter the title of [Primary] and [Secondary].
[Source]: Select the data source of [Primary] and [Secondary].
[Source (sub)]: Set the other data source in the same range as the data of [Primary].
The [Source (sub)] appears only when the source of [Secondary] is not entered.
[Unit]: Set the unit in the [Primary] and [Secondary].
[Scale Ň Range]: Set the display range of the X-coordinate. [Primary] is for the
range of the upper of the graph, [Secondary] is for the range of the lower of the
graph.
[Time Span]: Set the display range of the Y-coordinate.
[Sample Interval]: Set the interval of the graph plot.
[Scale Resolution]: Select the scale resolution of the graph.

1-91
1. INITIAL SETTING AND ADJUSTMENT

[Change button]: Check the checkbox to show the [Change] button. Click the
[Change] button to show the [Vertical Graph (Middle)] hidden behind. Check the
checkbox of [Show] in [Change Button] to show the component hidden behind.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Secondary (Y2) Scale]: Check the check box to show the value input from the data
source of [Secondary].
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the X-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.
• Winch

[Title]: Enter the title of the component.


[Type]: Select [Main only] or [Port and Stbd]. For [Main only], the information of only
the main winch is shown. For [Port and Stbd], the information of each winch on both
the port and starboard is shown.
[Length]: Set the source and unit of length for rope.
[Power]: Set the source and unit for rope winding force.
[Speed]: Set the source and unit for rope winding speed.
[Start Value]: Set the minimum value of the bar.
[End Value]: Set the maximum value of the bar.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
• Winch Information

[Title]: Enter the title of the component.


[Length]: Set the source and unit of length for rope.
[Power]: Set the source and unit for rope winding force.
[Speed]: Set the source and unit for rope winding speed.
[Decimal Place]: Check the checkbox to show the value after decimal point.

1-92
1. INITIAL SETTING AND ADJUSTMENT

[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
• Wind Direction

[Title]: Enter the title of the component.


[Location]: Select the reference point for the wind direction and speed from the pull-
down list.
[Theoretical]
[Label]: Enter the data name for the theoretical wind direction and speed.
[Source]: Select the data source of the theoretical wind direction and speed.
[Apparent]
[Label]: Enter the data name for the apparent wind direction and speed.
[Source]: Select the data source of the apparent wind direction and speed.
[Unit]: Set the unit of the wind direction and wind speed.
[Decimal Place]: Check the checkbox to show the value after decimal point.

[Large] component (three or more blocks)


• Alert

• Doppler Log

[Title]: Enter the title of the component.

1-93
1. INITIAL SETTING AND ADJUSTMENT

[SOG Longitudinal Speed]: Select the data source of the longitudinal SOG.
[STW Longitudinal Speed]: Select the data source of the longitudinal STW.
[Bow Transverse Speed]: Select the data source of the longitudinal speed at the
bow position.
[Stern Transverse Speed]: Select the data source of the longitudinal speed at the
stern position.
[True Wind Direction Source]: Select the source of true wind direction indicated as
the red triangle in the center of the component.
[Relative Wind Direction Source]: Select the source of relative wind direction indi-
cated as the red triangle in the center of the component.
[Speed Type Source]: Select the data source same as [Longitudinal Speed Source]
to show the abbreviated name of the data source unit.
[Sensor Name Source]: Select the appropriate sensor name source.
[Unit]: Set the unit of the ship’s speed.
[Decimal Place]: Check the checkbox to show the value after decimal point
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
[Mirror Vertically]: Check the checkbox to invert the display vertically.
• DP

For the setting, see the description for [Compass], [Horizontal Ruler], [Azimuth Pro-
motion], and [Doppler Log].

1-94
1. INITIAL SETTING AND ADJUSTMENT

• Fore & AFT bridge, Fore & AFT bridge (Wide) to Fore & AFT bridge9 (Wide)
Multiple components are combined on this window.
The contents are same as the single component.

• NAV Information

㼄㼀㻰㻌㻸㼕㼙㼕㼠
㼄㼀㻰

[Title]: Enter the title of the component.


[Component.Height]: Select the size of component.

1-95
1. INITIAL SETTING AND ADJUSTMENT

• Present Leg

㼄㼀㻰㻌㻸㼕㼙㼕㼠
㼄㼀㻰㻌

• Speed And Transverse

[Title]: Enter the title of the component.


[Location]: Select the reference point for the speed from the pull-down list.
[Speed Label]: Enter the title shown at the upper of the longitudinal speed value.
[Transverse Label]: Enter the title shown at the upper of the transverse speed value.
[SOG Longitudinal Speed]: Select the data source of the longitudinal SOG.
[STW Longitudinal Speed]: Select the data source of the longitudinal STW.
[CCRP Transverse Speed]: Select the data source of the longitudinal speed at the
CCRP position.
[Bow Transverse Speed]: Select the data source of the longitudinal speed at the
bow position.
[Stern Transverse Speed]: Select the data source of the longitudinal speed at the
stern position.
[Speed Type Source]: Select the data source same as [Longitudinal Speed Source]
to show the abbreviated name of the data source unit.
[Sensor Name Source]: Select the appropriate sensor name source.
[Unit]: Set the unit of the ship’s speed.
[Decimal Place]: Check the checkbox to show the value after decimal point
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.

1-96
1. INITIAL SETTING AND ADJUSTMENT

• Vertical Graph

[Title]: Enter the title of the component.


[Label]: Enter the title of [Primary] or [Secondary].
[Source]: Select the data source of [Primary] or [Secondary].
[Source (sub)]: Set the other data source in the same range as the data of [Primary].
The [Source (sub)] appears only when the source of [Secondary] is not entered.
[Unit]: Set the unit in the [Primary] or [Secondary].
[Scale Ň Range]: Set the display range of the X-coordinate. [Primary] is for the
range of the upper of the graph, [Secondary] is for the range of the lower of the
graph.
[Time Span]: Set the display range of the Y-coordinate.
[Sample Interval]: Set the interval of the graph plot.
[Scale Resolution]: Select the scale resolution of the graph.
[Change button]: Check the checkbox to show the [Change] button. Click the
[Change] button to show the [Vertical Graph (Middle)] hidden behind. Check the
checkbox of [Show] in [Change Button] of the component hidden behind.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Secondary (Y2) Scale]: Check the check box to show the value input from the data
source of [Secondary].
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the X-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.
• Vertical Heading Graph

[Title]: Enter the title of the component.


[Label]: Enter the title of [Heading] or [Other].

1-97
1. INITIAL SETTING AND ADJUSTMENT

[Source]: Select the data source of [Heading] or [Other].


[Source (sub)]: Set the other data source in the same range as the data of [Head-
ing]. The [Source (sub)] appears only when the source of [Other] is not entered.
[Unit]: Set the unit in the [Heading] and [Other].
[Scale Ň Range]: Set the display range of the X-coordinate. [Heading] is for the
range of the upper of the graph, [Other] is for the range of the lower of the graph.
[Time Span]: Set the display range of the Y-coordinate.
[Sample Interval]: Set the interval of the graph plot.
[Scale Resolution]: Select the scale resolution of the graph.
[Change button]: Check the checkbox to show the [Change] button. Click the
[Change] button to show the [Vertical Heading Graph] hidden behind. Check the
checkbox of [Show] in [Change Button] of the component hidden behind.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Secondary (Y2) Scale]: Check the check box to show the value input from the data
source of [Secondary].
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the X-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.

1.15 Network Transmission Setting Between


ECDIS and Radar
Connect the ECDIS and Radar (FAR-2uu7/FAR-2uu8/FCR-2uu9/FAR-3uu0 series)
with the LAN cable to show the radar echo and TT symbols on the ECDIS chart dis-
play, and show the ECDIS route and user chart symbol on the radar display.

For non-Furuno radar, the ECDIS chart display can not show the radar echo. The TT
symbol can be shown on the ECDIS chart display by connecting the ECDIS and radar
by serial interface.

Note: Confirm that the SPU board program version of the FAR-2uu7/FCR-2uu9 series
is version "03.50" or after.

For FAR-2uu7, FCR-2uu9 series


1. Turn on the DIP SW (S4) on the SPU board of FAR-2uu7 and FCR-2uu9 series.
The IP address of the radar processor unit is changed to "192.168.031.101".
2. To connect two antenna units, change the antenna number of second antenna
unit to "2" and set the IP address and subnet mask as shown below.
IP address: 192.168.031.102
Subnet mask: 255.255.255.0
3. Do one of the two procedures below according to the radar connected.
For FAR-2uu7 series
1) Press the MENU key to open the main menu.
2) Press and hold the 1 HL OFF key, then press the MENU key five times to open
the [INITIALIZE] menu.
3) Open [8. OTHERS] o [5. INS], then select [LAN].
4) Go back to the [INITIALIZE] menu and open [6. TT PRESET] o [2. TT DATA
OUTPUT], then select [TTM], [TRUE] and [4800].

1-98
1. INITIAL SETTING AND ADJUSTMENT

For FCR-2uu9 series


1) Press and hold the 1 HL OFF key, then press the MENU key five times.
2) Select [9 RADAR INSTALLATION]o[4 TT PRESET]o[1 TTM/TTD PREFER-
ENCE] and then select [TRUE].
4. Access the [Common Installation Setting] menu on the ECDIS.
5. Open the [Own Ship Setting] menu, then select [Radar Antenna] on the menu bar.
6. For one antenna unit, check [RAS001]. For two antenna units, check [RAS001]
and [RAS002].

For FAR-3uu0 series


1. Press and hold the 1 HL OFF key, then press the MENU key five times.
2. Select [9 RADAR INSTALLATION]o[4 TT PRESET]o[1 TTM/TTD PREFER-
ENCE] and then select [TRUE].
3. Access the [Common Installation Setting] menu on the ECDIS.
4. Open the [Own Ship Setting] menu, then select [Radar Antenna] on the menu bar.
5. For one antenna unit, check [RAS001]. For two antenna units, check[ RAS001]
and [RAS002].

For FAR-2uu8 series


1. Press and hold the 1 HL OFF key, then press the MENU key five times to open
the [RADAR INSTALLATION] menu.
2. Select [0 NEXT].
3. Select [2 NETWORK SETTINGS], then set [2 LAN1•3 IP ADDRESS] to [CLASS
C].
4. Go back to the first page of the [RADAR INSTALLATION] menu, then select [5 IN-
STALLATION].
5. Set the antenna number ([3 RADAR NO]), taking care not to duplicate the antenna
number of other radars.
6. Go back to the second page of the [RADAR INSTALLATION] menu, then select
[3 OTHER SETTINGS].
7. Set [4 ECDIS] to [LAN].
8. Go back to the first page of the [RADAR INSTALLATION] menu, then select [6 TT
PRESET] o [2 TT DATA OUTPUT].
9. Set [2 SELECT SENTENCE] to [TTM] or [TTD].
10. Set [3 TTM/TTD REFERENCE] to [TRUE].
11. If you want to share the ship’s speed and location data with the ECDIS, select
[ECDIS] on the either of the following menu items:
• Main menu o [7 INFORMATION BOX] o [2 OWN SHIP INFO] o [3 SPEED]
o [2 SHIP SPEED]
• Main menu o [7 IINFORMATION BOX] o [2 OWN SHIP INFO] o [4 OWN
SHIP POSN] o [2 POSITION SOURCE]
Note: The settings for the above two menu items are shared. When either one is
changed, the other is also changed.

1-99
1. INITIAL SETTING AND ADJUSTMENT

12. If you want to show the marks received from the ECDIS on the FAR-2uu8 screen,
open the main menu o [2 MARKS] o [6 ECDIS MARKS DISPLAY], then select
[ON] or [OFF] as appropriate.
13. Access the [Common Installation Setting] menu on the ECDIS.
14. Open the [Own Ship Setting] menu, then select [Radar Antenna] on the menu bar.
15. For one antenna unit, check [RAS001]. For two antenna units, check [RAS001]
and [RAS002].

For non-Furuno radar


1. Open [Installation Parameters]o[Sensor Setting]o[Other Sensor] menu.
2. Check [OTR001] and enter [RA0201] to [SFID]. Do not use other than [RA0201]
to [RA0204].
Note 1: When entering the SFID, do not use the prefix "AI" (AIS excluded) or "II".
Note 2: Do not enter the same SFID as any other equipment in the network.

3. Select [Serial Input/Output] of the processor unit you want to set on the menu bar.
4. Check the serial port to receive the TT symbol data and select [OTR001] from the
[Equipment ID] pull-down list.
The example shown below indicates that the [Serial 08] port of [ECD001] receives
the TT symbol data.

1-100
1. INITIAL SETTING AND ADJUSTMENT

1.16 How to Set the Forwarding Distance


Set the forwarding distance* as follows. The configuration can be copied to other units
connected to the network after saving the configuration.

*: The distance the ship travels straight after the steering control.

1. In the chart mode, press Ctrl, Shift and t keys simultaneously on the control unit
or keyboard.
The password input dialog box appears.

2. Enter the password and click the [OK] button.


Note: The service mode remains enabled until you press Ctrl, Shift and t keys
simultaneously or reboot the unit.
3. Click [Menu] to open the menu.
4. Click [Navigation Parameter] to show the [Navigation Parameter] setting window.

5. Enter [SPD kn] (ship speed), [Radius NM] (turning radius) and [FWD DIST NM]
(forwarding distance*).
6. When [FWD DIST NM] is different between port and starboard sides, check the
checkbox of [Use different values for Port and Starboard] and then enter each set-
ting value.

7. Click [Save] button to save the configuration.

1-101
1. INITIAL SETTING AND ADJUSTMENT

1.17 Synchronization With Ship’s Clock


The time (UTC) received from the GPS is shown. If the ZDA sentence is input from the
ship’s clock, the time synchronized with the ship’s clock can be shown.

Do as follows to activate the synchronization with the ship’s clock.

Note: The local time setting is not available when the synchronization with ship’s clock
is active.
1. In the chart mode, press Ctrl, Shift and t keys simultaneously on the control unit
or keyboard. The password input dialog box appears.
2. Enter the password and click the [OK] button.
Note: The service mode remains enabled until you press Ctrl, Shift and t keys
simultaneously or reboot the unit.
3. Click [MENU] to open the menu.
4. Click [Ship & Route Parameters], then click the [Function1] tab.

5. Click the [OFF] button of [Sync with ship’s clock] to set "ON".
6. Click the [Save] button to save the configuration.

1.18 How to Change the Color of Data in the Sensor


Information Box According to Integrity
The following procedure shows how to change the color of the data in the sensor in-
formation box with the results of the Integrity Check. For the Integrity Check, see the
Operator’s Manual for the Chart Radar.

1. In the chart mode, press Ctrl, Shift and t keys simultaneously on the control unit
or keyboard. The password input dialog box appears.
2. Enter the password and click the [OK] button.
Note: The service mode remains enabled until you press Ctrl, Shift and t keys
simultaneously or reboot the unit.
3. Click [MENU] to open the menu.

1-102
1. INITIAL SETTING AND ADJUSTMENT

4. Click [Ship & Route Parameters], then click the [Function2] tab.

5. Check the checkbox of [Color of own ship’s information (TEXT) will be changed
by result of integrity check].
6. Click the [Save] button to save the configuration.

1-103
1. INITIAL SETTING AND ADJUSTMENT

This page is intentionally left blank.

1-104
2. SETTING FOR SENSOR
ADAPTER
The default Equipment ID of the Sensor Adapter is [MCV016]. Set the individual
Equipment ID before connecting to the network.

Connect the Sensor Adapter to the processor unit after setting the Equipment ID. Then
enter the other settings of the Sensor Adapter from the [Common Installation Setting]
menu on the processor unit.

2.1 How to Set the Equipment ID


1. Set the IP address and subnet mask of the PC as shown below.
IP address: 172.31.16.200
Subnet mask: 255.255.0.0
2. Connect the laptop PC to the Sensor Adapter with the LAN cable.
3. Activate the web browser on the PC and enter the default IP address of the Sensor
Adapter: "172.31.17.108".
4. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.

MCV016
No.16 Sensor Adapter
MC-3000S

31 17 108

5. Select the Equipment ID from the pull-down list. The [Equipment Name], [Equip-
ment Type No.] and [IP Address] are automatically entered according to the
Equipment ID.
Setting range: [MCV001] to [MCV016]
6. After entering the setting, click [Save] on the info bar. Several confirmation mes-
sages appear. Click [OK] to reboot the system.
If you want to discard the entry, click [Discard Changes].

2-1
2. SETTING FOR SENSOR ADAPTER

How to restore the default Equipment ID


When you can not define the Equipment ID of the Sensor Adapter, restore the default
and set the Equipment ID again.

1. Turn on the No. 8 segment of the DIP switch S10 on the board in the MC-3000S.
2. Turn on the Sensor Adapter.
The Equipment ID of the Sensor Adapter turns to default [MCV016], and the IP
address is set to "172.31.17.108".
3. See "How to set the Equipment ID" to set the Equipment ID of the Sensor Adapter.
4. Turn off the No. 8 segment of the DIP switch S10 on the board in the MC-3000S.

2.2 How to Save the Log File


The log file of the Sensor Adapter can be saved to a medium (PC, USB memory, etc.).
The log file is used to check the status of the Sensor Adapter.

1. Connect the PC to the Sensor Adapter with the LAN cable.


2. Activate the web browser and enter the following address in the address bar.
"http://172.31.xx.xxx/cgi-bin/logall.cgi"
"172.31.xx.xxx" is the IP address of the Sensor Adapter where to save the log file.
3. After entering the address, the window to save the log file appears. Save the log
file to the PC.

2.3 How to Update the Firmware (MC-3000S)


This section shows you how to update the firmware program of the Sensor Adapter
MC-3000S.

Preparation
• PC that has a LAN port
Windows XP® is recommended. Disable the firewall and set the IP address and
subnet mask of the PC as shown below.
IP address: 172.31.16.200
Subnet mask: 255.255.0.0
• LAN cable
• Binary file for update
2450080-xxxxxxxx_mc_cs_boot.bin Boot program
2450081-xxxxxxxx_mc_cs_mainpg.bin Main program
2450082-xxxxxxxx_mc_cs_maint.bin Maintenance program
2450084-xxxxxxxx_mc_io_mainpg.bin Main program (analog, digital input,
and digital output board)
(xxxxxxxx: program version)

2-2
2. SETTING FOR SENSOR ADAPTER

2.3.1 How to activate the maintenance program


1. Turn off all Sensor Adapters.
2. Connect the applicable MC-3000S to the PC with the LAN cable.
3. Turn on the No. 6 of the DIP-SW (S10) on the MC-CS board (24P0114).
4. Turn on the Sensor Adapter MC-3000S.
5. The maintenance program activates after about 30 seconds. At this time, the IP
address of MC-3000S is changed to "172.31.17.108".
Confirm that the LED (CR 74) on the MC-CS board lights 3 times and goes off for
a while repeatedly.

2.3.2 How to confirm the firmware program version


1. Activate the maintenance program of the Sensor Adapter MC-3000S.
2. Activate the command prompt of Windows®.
3. Enter "telnet 172.31.17.108" on the command prompt.
4. Enter the user name and password correctly.

㸠㩷㩷Enter the telnet command.

㸠㩷㩷Enter the user name.


㸠㩷㩷Enter the user password.

5. Enter "/usr/sbin/version" on the command prompt to confirm the program version.


The program version is shown on the command prompt.

㸠㩷㩷The command to confirm the program version.

Boot program

Main program
Maintenance program
㸠㩷㩷After the confirmation the program version, enter “exit” .

Note: The image shown above is an example. The program version number may
be different.
6. After confirming the program version, enter "exit" to finish the telnet command.

2-3
2. SETTING FOR SENSOR ADAPTER

2.3.3 How to update the firmware program


1. Delete the version number from the firmware binary file name.

Example 䋺 2450081-01010088_mc_cs_mainpg.bin
Program number Version number

Delete the version number from the file name.

Example 䋺 2450081_mc_cs_mainpg.bin
2. Activate the maintenance program of the Sensor Adapter MC-3000S.
3. Activate the command prompt of Windows®.
4. Change the current directory to the directory where the firmware binary program
is saved.
In the example shown below, binary file is saved at 㪚㪑㩷㪳㫌㫇㪻㪸㫋㪼 .

% 㸠㩷㩷The command to change the current drive


EF>WRFCVG 㸠㩷㩷The command to change the current directory

Note: Change the current directory to the one where the binary file is saved.
5. Enter "ftp 172.31.17.108" on the command prompt.
Confirm that "220-MC3000_CS_MAINTENANCE" is shown.
6. Enter the user name and password.

IWS 䊹㻌㻌Enter the ftp command.


&RQQHFWHGWR
0&B&6B0$,17(1$1&( 䊹㻌㻌Confirm that this massage appears .
0&B&6B0$,17(1$1&()73VHUYHU 9HUVLRQ2SHQ%6'/LQX[IWSG UHDG\
1DPH WDQDNDWRVKLKLVD  䊹㻌㻌Enter the user name.
3DVVZRUGUHTXLUHGIRUURRW
3DVVZRUG㸸 䊹㻌㻌Enter the password.

2-4
2. SETTING FOR SENSOR ADAPTER

7. After the login, enter "dir".


The file names that are saved in the Sensor Adapter are displayed. Confirm that
the file names shown below are shown on the display.

1DPH WDQDNDWRVKLKLVD  䊹㻌㻌Enter the user name.


3DVVZRUGUHTXLUHGIRUURRW
3DVVZRUG㸸 䊹㻌㻌Enter the password.
8VHUURRWORJJHGLQ
5HPRWHV\VWHPW\SHLV81,;
8VLQJELQDU\PRGHWRWUDQVIHUILOHV
IWS!GLU 䊹㻌㻌Enter “dir” .
3257FRPPDQGVXFFHVVIXO
2SHQLQJ$6&,,PRGHGDWDFRQQHFWLRQIRU͂ELQOV̓
FUZUUURRWURRW6HSBPFBFVBERRWELQ
FUZUUURRWURRW6HSBPFBFVBPDLQSJELQ
FUZUUURRWURRW6HSBPFBFVBPDLQWELQ
FUZUUURRWURRW6HSBPFBLRBPDLQSJELQ
GUZU[U[URRWURRW6HSEDFNXS
7UDQVIHUFRPSOHWH Check these file names.
IWS!

8. Enter "bin", and then enter "hash".


9. Enter the command to transfer the firmware program.
Example: put 24500810_mc_cs_mainpg.bin
10. When you transfer other program, enter the command to transfer the program.
11. Enter "bye" to finish updating the firmware program.

IWS!ELQ 䊹㻌㻌Enter necessarily.

7\SHVHWWR,
IWS!KDVK 䊹㻌㻌Enter necessarily.
+DVKPDUNSULQWLQJRQ E\WHVKDVKPDUN 
IWS!SXWBPFBFVBPDLQSJELQ䊹㻌㻌The command to transfer the firmware program.
ORFDOBPFBFVBPDLQSJELQUHPRWHBPFBFVBPDLQSJELQ
3257FRPPDQGVXFFHVVIXO
2SHQLQJ%,1$5<PRGHGDWDFRQQHFWLRQIRU
BPFBFVBPDLQSJELQ


͐

7UDQVIHUFRPSOHWH
E\WHVVHQWLQVHFV N%V
IWS!E\H 䊹㻌㻌The command to finish the ftp command.
*RRGE\H

12. Confirm the firmware program version (see section 2.3.2.).

2-5
2. SETTING FOR SENSOR ADAPTER

This page is intentionally left blank.

2-6
3. DUAL GYRO SYSTEM
(ECDIS Only)
The dual gyro system by Yokogawa Denshikiki is available for the ECDIS. The system
configuration is as shown below. Then, to set the gyro sensors, do as follows.

HUB-3000

Contact signal
Heading switch status

No.3 GYRO
No.1 GYRO
(GYRO selector) No.2 GYRO
No.1 No.1
GPS No.1 GPS
Chart radar ECDIS
LOG No.2 GPS for TCS
LOG
Autopilot

Sensor Sensor
Adapter Adapter

Other sensors Other sensors

How to enable the dual gyro system


1. Open the [Installation Parameters] menu on the [Common Installation Setting]
menu.
2. Open the gyro selector setting window and check the checkbox to activate
[GYO001], [GYO002] and [GYO003].
3. Open the [Serial Input/Output Setting] window of the ECDIS and Chart Radar.
4. Check the checkbox or the serial port connected to the No.1 GYRO, No.2 GYRO,
No.3 GYRO (GYRO selector), and then select the Equipment ID from the pull-
down list.
5. Open the [Digital Input Setting] window of the ECDIS for TCS.
6. Check the checkbox of [Channel 01] and select [GYRO SELECTOR] from the
Data Category pull-down list.

3-1
3. DUAL GYRO SYSTEM (ECDIS Only)

7. Click [TCS] on the tab bar.

*
: Shown when [YOKOGAWA] is selected for [Manufacture].
8. Select the signal format for the gyro selector.
• [Digital]: Use the contact signal for the gyro selector.
• [Serial]: Use the contact signal for the gyro selector.
9. Set [Dual Gyro Setting] as shown below.
• [Gyro Selector]: GYO003
• [Digital In - Open]: GYO001
• [Digital In - Close]: GYO002
For the contact setting of the gyro selector, consult with a Yokogawa engineer.
10. To save the configuration, confirm the consistency of the configuration then save
the configuration data on the [Save and Sync] menu.
11. Confirm that the indication on the sensor information box is changed after switch-
ing the gyro sensor. If the indication on the sensor information box and Gyro sys-
tem is not synchronized, check the connection and configuration.
When the ECDIS for TCS is OFF, "GYRO3" appears in the sensor information
box.

This indication is changed after


switching the gyro sensor.

Example: Sensor information box

3-2
4. HUB-3000 IGMP QUERIER
SETTING
When constructing a network with two or more FAR-2uu7 radars via HUB-3000, set
the IGMP querier of the HUB-3000.

Parts and equipment needed


• PC with the RS-232C serial port (D-SUB 9 pin connector)
• RS-232C cross cable (D-SUB 9 pin)
• Software to control the serial device (Hyper Terminal, Tera Term, Putty, etc.)

RS-232C cross cable

Pin assign (female) Pin no. Signal Connection


1 NC
2 RD 㪈 㪈
3 SD 㪉 㪉
㪊 㪊
㪌 㪈 4 NC
㪋 㪋
5 SG
㪌 㪌
㪐 㪍 6 NC 㪍 㪍
7 NC 㪎 㪎
㪏 㪏
8 NC
㪐 㪐
9 NC
Frame FG

Procedure
This document shows the procedure with the software "Tera Term".

1. Connect the RS-232C cross cable to serial port of PC.


2. Connect the RS-232C cross cable to serial port of HUB-3000.
Note: When disconnecting the RS-232C cross cable, disconnect it from HUB-
3000 and then disconnect from PC.
3. Activate "Tera Term" on PC.
4. Check the radio button of [Serial] and the select the COM port from the pull-down
list.

COM1: Serial port (COM1)

4-1
4. HUB-3000 IGMP QUERIER SETTING

5. Click [OK].
6. Click [Setup], [Serial Port] to show the setting window.

7. Set the options as shown below on the setting window.


• [Baud rate]: 9600 • [Data]: 8 bit • [Parity]: none
• [Stop]: 1 bit • [Flow control]: none

8. Press the Enter key on "Tera Term".


You are asked to enter the user name and password.
9. Enter the user name and password as shown below.

Username: admin
Password: admin
Welcome to HUB-3000 GigabitHUB
Switch>

• [User name]: admin • [Password]: admin

10. Enter the word "enter" and press the Enter key.
11. Press the Enter key again.
12. Enter "show ip igmp-snooping" in the "Switch#" field and press the Enter key.
Confirm the configuration of HUB-3000. When "Disabled" appears in the "Querier"
field, do the following.
Switch>㩷 enter
Switch#Jan 1 20:32:14 User admin enter privilege mode from console 0, level
= 15
Switch#㩷 show ip igmp-snooping

Global IGMP snooping configuration:


-----------------------------------
Globally enable : Enabled
VLAN nodes : 1
Dlf-frames filtering : Enabled
Sensitive : Disabled
Querier : Disabled
Querier address : 10.0.0.200
㩷 Router age : 260 s

13. Enter "config" and press the Enter key.


14. Enter "ip igmp-snooping querier" and press the Enter key.
15. Enter "show ip igmp-snooping" and press the Enter key.
16. Confirm that "Enabled" appears in the "Querier" field.

4-2
4. HUB-3000 IGMP QUERIER SETTING

17. Enter "write" and press the Enter key.


Reboot the HUB-3000 after performing "write" to enable the querier function of
HUB-3000.

Switch# config

Switch_config# ip igmp-snooping querier


Switch_config# show ip igmp-snooping

Global IGMP snooping configuration:


-----------------------------------
Globally enable : Enabled
VLAN nodes : 1
Dlf-frames filtering : Enabled
Sensitive : Disabled
Querier : Enabled
Querier address : 10.0.0.200
Router age : 260 s
Response time : 15 s

Switch_config# write
Saving current configuration...
OK!

18. Reboot the HUB-3000.


19. Refer to steps 6 to 11 to confirm the configuration of the HUB-3000.
Confirm that "Enabled" appears in the "Querier" field. If not, retry the IGMP querier
setting.

4-3
4. HUB-3000 IGMP QUERIER SETTING

This page is intentionally left blank.

4-4
5. RAYTHEON ANSCHUTZ AUTO-
PILOT NP-5400
The Raytheon Anschutz Autopilot NP-5400 is different from other autopilots in many
respects, thus distinctive settings are required at the FMD. This chapter presents the
information necessary to set up the FMD for use with the NP-5400.

All cables from the HCS, Other Sensor 1, Other Sensor 2 and the BNWAS should be
connected to the No.1 ECDIS (ECD001). Set the appropriate sensors and connec-
tions according to your installation configuration (wiring, etc.). The settings for sensors
(GPS, gyro, log, etc.) are omitted from this chapter.

Access the [Common Installation Settings] as shown in section 1.1, then follow the
procedures in this chapter.

5.1 Installation Parameters

5.1.1 HCS setting


1. Open [Sensor Setting]o[HCS], then check [HCS001].

2. Click the [Details] button, then make [System Alert ID] blank (------).

Note: The System Alert ID is set to blank so that the EC-3000 ignores the alert
sentence (ALF sentence, etc.) received from the Equipment ID sensor. However,
with connection of the NP-5400, there is no effect on Alerts handled by the TCS.

5-1
5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400

5.1.2 NP-5400 alert and backup navigator setting


Use “Other Sensor” for the connection between the NP-5400 and the AMS. For exam-
ple, use [Other Sensor 1] for “Alert” as follows.

On the [Other Sensor - OTR001] setting screen, set [Alert Information Source] to [Alert
Sentence], and set [Sensor Name] to [Autopilot] or [NP-5400].

5.1.3 BNWAS setting


The BNWAS sub menu provides the necessary settings when both an AMS and a BN-
WAS are installed. Check [WAS001], then confirm settings.

5-2
5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400

5.1.4 Serial ports configuration


Configure the serial port connected to each port (TCS, alert, speed, position, and time)
on the NP-5400.

Below is a connection example.

z EC-3000 z Sensor Adapter


• Ch2: HCS001 • Ch3: HCS001 (for position and time)
• Ch3: OTR001 • Ch4: HCS001 (for speed)
• Ch4: OTR001
• Ch5: WAS001

Set all baud rates to 4800 bps.

Setting at EC-3000

Setting at Sensor Adapter

5-3
5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400

5.2 TCS Port Setting


Output setting
Communication (input/output sentences) between the FMD and NP-5400 for the TCS
application are as shown in the table below.

FMDoNP-5400 NP-5400oFMD
APB ALF
HTD ALC
PANZCRQ AGHDT
PANZEST AGHSC
PANZPSR AGTHS
PANZHTD HRSA
— PANZRSA
— PANZSRR
— PANZSTA

Set the sentences to be output from the FMD to the NP-5400. Note that if [Source
SFID] ([TCS] tab o[Other Setting]) is set for [TCS SFID], the following setting method
is available:
Data Source: ECD001/TCS(TCS0001), Formatter: ***

TCS SFID setting

Output setting used by TCS SFID


Note: As before, when using Data Source: ECD0xx/ECDIS (EI00xx), fill in all the sen-
tences to be output. (xx is 01 to 16).

Input setting
No setting required.

5-4
5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400

5.3 NP-5400 Alert Port Setting


This setting connects the FMD to the NP-5400’s MOXA LAN-Serial Converter (BAM).
For the output setting, like the normal Alert related setting, check the check box at
"Output sentence name with destination this with sensor.".

5.4 NP-5400 Backup Navigator Port Setting


This setting connects the FMD to the NP-5400’s MOXA LAN-Serial Converter (BN-
WAS). For the output setting, like the Alert setting, check the check box at "Output
sentence whose destination corresponds with this sensor.".

5.5 Position and Time Ports Settings


Position and time must always be transmitted from the FMD to the NP-5400. Set the
position and time ports as shown below.

By using "Position" and "Time", position and time data from the Sensor Adapter are
transmitted even when the EC-3000 is not powered, since data is output from the rep-
resentative sensor.
Note: The GPS sensor should output only the GLL sentence to the NP-5400. This pre-
vents the CCRS from outputting other position sentences (GGA, etc.) which can cause
receiving error at the NP-5400. Therefore, configure the input filter on the port where
the GPS sensor is connected so that it receives only the GLL sentence.

5-5
5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400

5.6 Speed Port Setting


Speed data must always be transmitted
from the FMD to the NP-5400. Set the
speed port as shown to the right.

5.7 Backup Navigator Setting


The backup navigator (ALR sentence) can be output as shown below. Do this when a
BNWAS is connected.

Transfer Alerts: YES


Outport: WAS0001
Anschutz AP: OTR001
Alert No.: 20084

A specific alert is output from the NP-5400 as the “backup navigator alarm.” The alert
is converted to the ALR sentence and output to the FMD.

5.8 Save and Sync


Do save and sync (see section 1.10) after completing the settings in this chapter. (To
be sure the settings are saved, restart all EC-3000 units after completing the save and
sync. The Sensor Adapter is restarted together with the EC-3000 units.)
Confirm that the NP-5400 does not generate an alert for position, speed, etc. Also, ac-
tivate TCS and confirm that the NP-5400 does not generate an alert with the FMD
powered on or off.

5-6
APPENDIX 1 EQUIPMENT ID List
Gateway Sensor
Equipment ID Equipment Name Remarks
Network Network
MFD001 No.1 MFD 192.168.31.51 172.31.16.51
MFD002 No.2 MFD 192.168.31.52 172.31.17.51
MFD003 No.3 MFD 192.168.31.53 172.31.16.52
MFD004 No.4 MFD 192.168.31.54 172.31.17.52
MFD005 No.5 MFD 192.168.31.55 172.31.16.53
MFD006 No.6 MFD 192.168.31.56 172.31.17.53
MFD007 No.7 MFD 192.168.31.57 172.31.16.54
MFD008 No.8 MFD 192.168.31.58 172.31.17.54
MFD009 No.9 MFD 192.168.31.59 172.31.16.55
MFD010 No.10 MFD 192.168.31.60 172.31.17.55
MFD011 No.11 MFD 192.168.31.61 172.31.16.56
MFD012 No.12 MFD 192.168.31.62 172.31.17.56
MFD013 No.13 MFD 192.168.31.63 172.31.16.57
MFD014 No.14 MFD 192.168.31.64 172.31.17.57
MFD015 No.15 MFD 192.168.31.65 172.31.16.58
MFD016 No.16 MFD 192.168.31.66 172.31.17.58
Default setting for pro-
ECD001 No.1 ECDIS 192.168.31.1 172.31.16.1
cessor unit (ECDIS)
ECD002 No.2 ECDIS 192.168.31.2 172.31.17.1
ECD003 No.3 ECDIS 192.168.31.3 172.31.16.2
ECD004 No.4 ECDIS 192.168.31.4 172.31.17.2
ECD005 No.5 ECDIS 192.168.31.5 172.31.16.3
ECD006 No.6 ECDIS 192.168.31.6 172.31.17.3
ECD007 No.7 ECDIS 192.168.31.7 172.31.16.4
ECD008 No.8 ECDIS 192.168.31.8 172.31.17.4
ECD009 No.9 ECDIS 192.168.31.9 172.31.16.5
ECD010 No.10 ECDIS 192.168.31.10 172.31.17.5
ECD011 No.11 ECDIS 192.168.31.11 172.31.16.6
ECD012 No.12 ECDIS 192.168.31.12 172.31.17.6
ECD013 No.13 ECDIS 192.168.31.13 172.31.16.7
ECD014 No.14 ECDIS 192.168.31.14 172.31.17.7
ECD015 No.15 ECDIS 192.168.31.15 172.31.16.8
ECD016 No.16 ECDIS 192.168.31.16 172.31.17.8
RAD001 No.1 Radar 192.168.31.21 172.31.16.11
RAD002 No.2 Radar 192.168.31.22 172.31.17.11
RAD003 No.3 Radar 192.168.31.23 172.31.16.12
RAD004 No.4 Radar 192.168.31.24 172.31.17.12
RAD005 No.5 Radar 192.168.31.25 172.31.16.13
RAD006 No.6 Radar 192.168.31.26 172.31.17.13
RAD007 No.7 Radar 192.168.31.27 172.31.16.14
RAD008 No.8 Radar 192.168.31.28 172.31.17.14
RAD009 No.9 Radar 192.168.31.29 172.31.16.15
RAD010 No.10 Radar 192.168.31.30 172.31.17.15
RAD111 No.1 FAR-2uu8 Radar 192.168.31.21 172.31.16.11

AP-1
APPENDIX 1 EQUIPMENT ID List

Gateway Sensor
Equipment ID Equipment Name Remarks
Network Network
RAD112 No.2 FAR-2uu8 Radar 192.168.31.22 172.31.17.11
RAD113 No.3 FAR-2uu8 Radar 192.168.31.23 172.31.16.12
RAD114 No.4 FAR-2uu8 Radar 192.168.31.24 172.31.17.12
RAD115 No.5 FAR-2uu8 Radar 192.168.31.25 172.31.16.13
RAD116 No.6 FAR-2uu8 Radar 192.168.31.26 172.31.17.13
RAD117 No.7 FAR-2uu8 Radar 192.168.31.27 172.31.16.14
RAD118 No.8 FAR-2uu8 Radar 192.168.31.28 172.31.17.14
Default setting for pro-
CRA001 No.1 Chart Radar 192.168.31.31 172.31.16.21 cessor unit (Chart ra-
dar)
CRA002 No.2 Chart Radar 192.168.31.32 172.31.17.21
CRA003 No.3 Chart Radar 192.168.31.33 172.31.16.22
CRA004 No.4 Chart Radar 192.168.31.34 172.31.17.22
CRA005 No.5 Chart Radar 192.168.31.35 172.31.16.23
CRA006 No.6 Chart Radar 192.168.31.36 172.31.17.23
CRA007 No.7 Chart Radar 192.168.31.37 172.31.16.24 Do not select.
CRA008 No.8 Chart Radar 192.168.31.38 172.31.17.24
CRA009 No.9 Chart Radar 192.168.31.39 172.31.16.25
CRA010 No.10 Chart Radar 192.168.31.40 172.31.17.25
Default setting for ra-
RAS001 No.1 Radar Sensor 192.168.31.101 -
dar processor unit
RAS002 No.2 Radar Sensor 192.168.31.102 -
RAS003 No.3 Radar Sensor 192.168.31.103 -
RAS004 No.4 Radar Sensor 192.168.31.104 -
RAS005 No.5 Radar Sensor 192.168.31.105 -
RAS006 No.6 Radar Sensor 192.168.31.106 -
RAS007 No.7 Radar Sensor 192.168.31.107 -
Do not select.
RAS008 No.8 Radar Sensor 192.168.31.108 -
RAS009 No.9 Radar Sensor 192.168.31.109 -
RAS010 No.10 Radar Sensor 192.168.31.110 -
MCV001 No.1 Sensor Adapter - 172.31.16.101
MCV002 No.2 Sensor Adapter - 172.31.17.101
MCV003 No.3 Sensor Adapter - 172.31.16.102
MCV004 No.4 Sensor Adapter - 172.31.17.102
MCV005 No.5 Sensor Adapter - 172.31.16.103
MCV006 No.6 Sensor Adapter - 172.31.17.103
MCV007 No.7 Sensor Adapter - 172.31.16.104
MCV008 No.8 Sensor Adapter - 172.31.17.104
MCV009 No.9 Sensor Adapter - 172.31.16.105
MCV010 No.10 Sensor Adapter - 172.31.17.105
MCV011 No.11 Sensor Adapter - 172.31.16.106
MCV012 No.12 Sensor Adapter - 172.31.17.106
MCV013 No.13 Sensor Adapter - 172.31.16.107
MCV014 No.14 Sensor Adapter - 172.31.17.107
MCV015 No.15 Sensor Adapter - 172.31.16.108
Default setting for sen-
MCV016 No.16 Sensor Adapter - 172.31.17.108
sor adapter

AP-2
APPENDIX 2 SUBSYSTEM
Where the network configuration requires the use of a HUB-3000, the [Subsystem] settings must
also be configured. For example, in a configuration like the one below, if the Subsystem settings
are not configured, No. 1 ECDIS can only receive data from No. 1 Gyro, and No. 2 ECDIS can
only receive data from No. 2 Gyro.

By configuring the Subsystem settings, the HUB-3000 allows the sharing of sensor data between
No. 1 ECDIS and No. 2 ECDIS.

No. 1 GYRO No.1 No.1 No. 2 Gyro


HUB-3000
ECDIS ECDIS

Sensor Sensor
Adapter Adapter

Other sensors Other sensors


Subsystems A to Z are defined as follows:

• Subsystem A: Configurations which include Sensor Adapters connected to a HUB-100.


• Subsystem B to Z: Configurations where Sensor Adapters are directly connected to the PCU.
Examples of Subsystem settings are:

• Subsystem A: No. 2 Chart Radar, No.2 ECDIS, No. 3 ECDIS


• Subsystem B: No. 1 ECDIS
• Subsystem C: No. 1 Chart Radar

HUB-3000

Subsystem C Subsystem B Subsystem A

GYRO No. 1 GYRO No. 1 GYRO No. 1 GYRO GYRO


No. 1 No. 2 GYRO No.1 No. 2 GYRO No.2 No. 2 GYRO No.3 No. 2
GPS Chart GPS Chart
No. 1 GPS No. 1 GPS No. 1 GPS
LOG No. 2 GPS ECDIS No. 2 GPS ECDIS No. 2 GPS ECDIS LOG
Radar Radar
Contact signal
Heading change
Status
HUB-100

Sensor Sensor Sensor Sensor


Adapter Adapter Adapter Adapter

Other Other Other Other


Sensors Sensors Sensors Sensors

AP-3
APPENDIX 3 RCB-002 IP ADDRESS
SETTING
When multiple Radar Connection Box RCB-002s are connected to the same network, change the
IP address as follows. Assign a different IP address to each RCB-002. IP address setting is not
required for configurations with a single RCB-002.

Preparation
• PC: Used for LAN connection with the RCB-002
• LAN cable: Used for connection between PC and RCB-002
• IP address setting tool (IPSetting.exe): Download from “Tech-Net” and save it on the PC.

Procedure
1. Set the IP address and subnet mask for the PC as follows.
• IP address: 192.168.31.110
• Subnet mask: 255.255.255.0
2. Connect the PC to the RCB-002, using a LAN cable.

RCB-002

PC

LAN cable

3. Turn on the RCB-002 power.


4. Run the IP address setting tool (IPSetting.exe) on the PC.

5. Confirm that “RD031111 (RCB-002)” and “192.168.031.111” appear on the [RCB-002 IP Set-
ting] window.
Note: When the indication on the [RCB-002 IP Setting] window is not correct, confirm the fol-
lowing points.
• Confirm that the IP address and subnet mask setting for the PC is correct.
• Check the connection between the PC and RCB-002. Reconnect as necessary.

AP-4
APPENDIX 3 RCB-002 IP ADDRESS SETTING

6. Enter the IP address as follows, then click the [SET] button.


• No.1 RCB: 192.168.031.111 (Default setting) • No.3 RCB: 192.168.031.113
• No.2 RCB: 192.168.031.112 • No.4 RCB: 192.168.031.114

7. Click the [CLOSE] button.


8. Run the IP address setting tool (IPSetting.exe) on the PC again, then the IP address entered
at step 6 appear in the [RCB-002 IP Setting] window.
Note: If the IP address setting is not applied, reboot the RCB-002 and PC, then retry step 4
to step 8.

AP-5

You might also like