This document provides correction factors for calculating the brake horsepower, capacity, head, and efficiency of a pump when pumping viscous liquids compared to water. It includes a viscosity correction chart and an example calculation for pumping a 50% sodium hydroxide solution that has a specific gravity of 1.53 and a viscosity of 78 centistokes or 120 centipoise. The example shows how to use the correction factors to determine the viscous brake horsepower when pumping at a given flow rate and head.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
570 views
Viscosity Correction Chart
This document provides correction factors for calculating the brake horsepower, capacity, head, and efficiency of a pump when pumping viscous liquids compared to water. It includes a viscosity correction chart and an example calculation for pumping a 50% sodium hydroxide solution that has a specific gravity of 1.53 and a viscosity of 78 centistokes or 120 centipoise. The example shows how to use the correction factors to determine the viscous brake horsepower when pumping at a given flow rate and head.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Back Next
PUMP DATA
CORRECTION FACTORS HEAD IN FEET
CAPACITY GALLONS PER MINUTE (at bep) Fig. 1
VISCOSITY CORRECTION CHART Example - Viscosity WHERE Determine BHPvis when pumping 66 usgpm at 80 ft. of 50% BHPvis = Viscous brake horsepower NaOH with a pump at 48% Eff. with water. S.G. = Specific Gravity *S.G. = 1.53 *Given from other tables 3960 = Constant *Visc = 78cSt = 120 CP/1.53 Qw = Capacity pumping water (USGPM) Qw = 66 usgpm Cq = Capacity correction factor (Fig 1) H.W. = 80 ft. Qvis = Viscous Capacity (USGPM) = Cq X Qw E.W. = 48% = .48 Hw = Head pumping water (ft.) Cq = .84 ) CH = Head correction factor (Fig 1) Ch = 1.00 ) From above chart Hvis = Viscous head (ft) = Ch X Hw Ce = .58 Ew = Efficiency pumping Water Qw x Cq = 66 x .84 = 55.44 Ce = Efficiency correction factor (Fig 1) Hw x Ch = 80 x 1.00 = 80.0 Evis = Viscous Efficiency = Ce X Ew Ew x Ce = .48 x .58 = .2784 BHPvis = (cq X Qs) X (Hw X Ch) X S.G. BHPvis = 55.44 x 80.0 x 1.53 3960 x .2784 = 6.16 H.P. 3960 x (Ce X Evis) 9 ALL TAXES EXTRA • PRICES SUBJECT TO CHANGE WITHOUT NOTICE • F.O.B. STOCKING POINT • MINIMUM BILLING $25.00 • CALL OR WRITE FABCO YOUR SOURCE FOR PLASTIC MATERIALS 9-63