Viscosity Correction Chart

This document provides correction factors for calculating the brake horsepower, capacity, head, and efficiency of a pump when pumping viscous liquids compared to water. It includes a viscosity correction chart and an example calculation for pumping a 50% sodium hydroxide solution that has a specific gravity of 1.53 and a viscosity of 78 centistokes or 120 centipoise. The example shows how to use the correction factors to determine the viscous brake horsepower when pumping at a given flow rate and head.

Uploaded by

Rodolfo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
570 views

Viscosity Correction Chart

This document provides correction factors for calculating the brake horsepower, capacity, head, and efficiency of a pump when pumping viscous liquids compared to water. It includes a viscosity correction chart and an example calculation for pumping a 50% sodium hydroxide solution that has a specific gravity of 1.53 and a viscosity of 78 centistokes or 120 centipoise. The example shows how to use the correction factors to determine the viscous brake horsepower when pumping at a given flow rate and head.

Uploaded by

Rodolfo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Back Next

PUMP DATA

CORRECTION FACTORS
HEAD IN FEET

CAPACITY GALLONS PER MINUTE (at bep) Fig. 1


VISCOSITY CORRECTION CHART
Example - Viscosity WHERE
Determine BHPvis when pumping 66 usgpm at 80 ft. of 50% BHPvis = Viscous brake horsepower
NaOH with a pump at 48% Eff. with water. S.G. = Specific Gravity
*S.G. = 1.53 *Given from other tables 3960 = Constant
*Visc = 78cSt = 120 CP/1.53 Qw = Capacity pumping water (USGPM)
Qw = 66 usgpm Cq = Capacity correction factor (Fig 1)
H.W. = 80 ft. Qvis = Viscous Capacity (USGPM) = Cq X Qw
E.W. = 48% = .48 Hw = Head pumping water (ft.)
Cq = .84 ) CH = Head correction factor (Fig 1)
Ch = 1.00 ) From above chart Hvis = Viscous head (ft) = Ch X Hw
Ce = .58 Ew = Efficiency pumping Water
Qw x Cq = 66 x .84 = 55.44 Ce = Efficiency correction factor (Fig 1)
Hw x Ch = 80 x 1.00 = 80.0 Evis = Viscous Efficiency = Ce X Ew
Ew x Ce = .48 x .58 = .2784 BHPvis = (cq X Qs) X (Hw X Ch) X S.G.
BHPvis = 55.44 x 80.0 x 1.53
3960 x .2784
= 6.16 H.P.
3960 x (Ce X Evis)
9