Installation Manual ZVIEW - For HUMAN (ENG)
Installation Manual ZVIEW - For HUMAN (ENG)
DR Console Software
Install Manual
(for HUMAN)
Table of Contents
1. Introduction ................................................................................ 4
2. Purpose ......................................................................................... 4
3. System requirements ............................................................... 5
2
Digital Radiography Console Software ZView
5.Appendix ........................................................................................ 50
3
Digital Radiography Console Software ZView
1. Introduction
Zview is the name of the digital radiography of Atlaim Co. Ltd.
Zview is the DR control software that acquires image from the DR
detector like flat panel, processes rapidly for clinical application, and
provides DICOM services for the integration with PACS system. This
manual explains how to install and operate Zview software.
(Manufacturer: ATLAIM Co., LTD.)
2. Purpose
ZView is the operation console system software integrated with
ATLAIM detectors or X-ray generator, based on FS-MLW (Faster
Specialized Multi Layered Wavelet) technology.
ZView is the product developed for the operator, designed at the
clinical hospital through many years of clinical tests, and finished by
service engineers.
ZView is the embedded software based on feel-TK enable to remove
noise and various artifacts and much clearer body tissue. The
embedded calibration function makes it possible to set the basic
calibration data (offset image and gain image).
It can also process progressive defect by providing defect view.
ZView is distributed and being used at the clinical fields after verifying
4
Digital Radiography Console Software ZView
3. System requirements
3.1. Workstation
Processor : Intel Pentium Intel Duo Core/Core 2 Duo or
compatible AMD Dual Core Processor or later, Win 7 : Intel i5
Second generation 2.0Ghz or above
RAM : 2GB RAM
HDD: At least 40GB hard disk (if possible, over 7,200 RPM). For
data backup and reliability, we recommend two separate
HDDs physically-1st HDD: System and Software, 2 HDD: Image
Data Storage, not separating the partition logically with just
one HDD.
Network Card : 1Gbps Ethernet Network Card
Video graphic adapter: at least over 1280 X 900 pixels, color
resolution-True Color mode(no shard memory), DVI interface
connector
Operating System : Windows 7 32/64 bit(at least SP1),
Windows XP
prof.(at least SP2), Windows 2000 prof.(at least SP4)
Need I/O : 1 Parallel port(synchronize Detector & X-ray
Generator & Software), 1 Serial port(in case Control of X-ray
generator), 1 USB port(Software Lock-Key)
3.2. Monitor
Over 19 inch (23 inch recommended)
Brightness : over 300cd/m2
Contrast Ratio : over DC 8000:1
Response time : over 5 ms
1600X1200 or 1920X1280 recommended (at least over 1280 X 900)
5
Digital Radiography Console Software ZView
6
Digital Radiography Console Software ZView
If you want to install on your new PC or reinstall after removing the old
version, please follow the below procedures.
Do not create a folder with other languages except English or long route
when using after copying the installation CD on your hard disk. It can make
problems when installing the driver.
7
Digital Radiography Console Software ZView
If the .Net Framework 3.5 SP1 is not installed, install the .Net
framework first. If it is installed already, go to the next screen.
After installing the .Net Framework, make sure to reboot your PC. The
installation process continues after rebooting.
When you have installed the .Net Framework, you should reboot PC.
Afterward, the installation is progressing continuously.
8
Digital Radiography Console Software ZView
The list is displayed the fixed drive, not are displayed CD-ROM or
Floppy disk. We recommend Zview to set up to Drive C:
“When you get the above message meaning the memory space is
less than 10GB, you can click “Yes” to continue. You need at least
10GB to install this software. This memory space includes created
data to be added after installation.
“When you get the above message meaning the same folder name
exists in the drive to install, you can not continue. For continuation,
you need to change the folder name in the drive as “_bak” into a
different name.
This is for the case that other software with the same name was
installed and the case that the backup was not done after removing
the previous installation.”
9
Digital Radiography Console Software ZView
Select the route of data to be installed. From the below list, select the
drive and click “Next”.
This is for the case that other software with the same
name was installed and the case that the backup was
not done after removing the previous installation
10
Digital Radiography Console Software ZView
Note
- If you have any other detector to add, please contact our sales staff.
-The available installed detectors are different by DR System Company.
11
Digital Radiography Console Software ZView
Select the type of the generator to use. From the below list, select the
generator and click “Next”. If you do not connect a generator, select
“DO NOT CONNECT GENERATOR” at the bottom of the list.
Note
“If you have any generator to add or connect, please contact our
sales staff.”
“ The contents of installation version is different according to
customers that’s because this version is fixed to applicable model. “
“If the model of generator is empty, please contact service staff”
12
Digital Radiography Console Software ZView
13
Digital Radiography Console Software ZView
You install the drivers to use in this process. It works automatically and
never stops compulsively.
By manual, reboot the system after looking for the path of drive
and finishing the installation
14
Digital Radiography Console Software ZView
15
Digital Radiography Console Software ZView
4.11.1. Detector
Refer to the detector instructor of the respective manufacturer.
16
Digital Radiography Console Software ZView
4.11.2. Generator
(1) GENERATOR
17
Digital Radiography Console Software ZView
(3) ETC
i. 12 bit send
: To send the 12 bit dicom file must be set.
The rest part does not check this Because the raw data value is up to
14 bit. But PACS system is applies to process only 12 bit , always
check it .
ii. Interpolation
: This option is that you can choose ON/OFF of interpolation at the
time of image loading in review mode. When the images load in the
18
Digital Radiography Console Software ZView
review mode, the Zview apply interpolation for all images. So the
loading time needs more time according to image count.
But if you turn off this option, the Zview does interpolation when you
work as using windowing, panning, zooming.
iii. AutoCrop
: This function is available in the only exposure mode.
The image size is automatically modified by adjusting the collimator
size of x-ray tube.
This function is operated only one time automatically.
Also it is possible to use the manual mode after releasing the this
one.
19
Digital Radiography Console Software ZView
v. Reject
: This function applies to cancel the examination or reject the
acquired image after exposure and “Reject” mark is displayed on the
image. The image data is not able to use for diagnostic purpose and
does not delete the image from the saved drive. If the check is
released, the image will be deleted with cancellation.
vi.Analysis
: If you want to know analysis or statistics for the used DR console
station, you can use this function. This function informs you of
Exposure counts, Dicom sending and rejected image counts. And you
can check the rejected analysis that is done by operator.
vii. Sensitivity
: Check this function when you want to display the Exposure Index or
Exposure Indicator on the image.
20
Digital Radiography Console Software ZView
x. Show Wifi UI
When you use wireless detector, do checked this check box.
You can see the status of WIFI sensitivity and Battery.
(4) DAP
i. Use DAP
Check this check box when you use DAP.
ii. Type
Select DAP Type
iii. Comport
When you connect Vacutec and iba directly, setup COM port No.
21
Digital Radiography Console Software ZView
4.11.3. System
22
Digital Radiography Console Software ZView
Note
③ The feelVIEW is special viewer for detail seeing image using Medical
or high resolution monitor.
Pos X : X coordinates for opening feelVIEW windows
Pos Y : Y coordinates for opening feelVIEW windows
Width : Width of feelVIEW Monitor’ resolution
Height : Height of feelVIEW Monitor’ resolution
23
Digital Radiography Console Software ZView
24
Digital Radiography Console Software ZView
25
Digital Radiography Console Software ZView
B. Setup
i. Start -> Control Panel - > Network
ii. After check NIC(detector NIC or PACS NIC), you have to change
select the PACS network and click the right button of mouse after
selecting‘properties‘.
26
Digital Radiography Console Software ZView
iv. Check the box in the red window and click the “OK” to finish.
27
Digital Radiography Console Software ZView
28
Digital Radiography Console Software ZView
Select ‘pacs’ and click the button, and then confirm the changing
connection order and click the ‘OK’ button
29
Digital Radiography Console Software ZView
30
Digital Radiography Console Software ZView
Note
“You don’t need this step on the Windows 7 Operation system”
31
Digital Radiography Console Software ZView
Window XP
This setup is for the stability of management of memory and store
image.
32
Digital Radiography Console Software ZView
33
Digital Radiography Console Software ZView
34
Digital Radiography Console Software ZView
F. Change or setup.
35
Digital Radiography Console Software ZView
Window 7
36
Digital Radiography Console Software ZView
37
Digital Radiography Console Software ZView
38
Digital Radiography Console Software ZView
4.13.4. DEP
DEP Setup in WindowsXP
39
Digital Radiography Console Software ZView
40
Digital Radiography Console Software ZView
41
Digital Radiography Console Software ZView
42
Digital Radiography Console Software ZView
i. System
Control Panel System and Security System
43
Digital Radiography Console Software ZView
ii. Click the Advanced system Setting and then the System Properties
window will be shown. And then move the Advanced Tab and click the
Settings button of Performance
iii. When the Performance Options window show, move the Data
Execution Prevention Tab and then select ‘Turn on DEP for all programs
and services except those I select’
iv. Click the ‘Add…’ button and select two files as like below
Zview.exe
WBMaker.exe
44
Digital Radiography Console Software ZView
45
Digital Radiography Console Software ZView
v. Confirm the ‘Zview’ and ‘WBMaker’ was included in List and then
click ‘Apply’ button
46
Digital Radiography Console Software ZView
47
Digital Radiography Console Software ZView
48
Digital Radiography Console Software ZView
49
Digital Radiography Console Software ZView
5. Appendix
5.1. DICOM MWL interface by Text file
5.1.1. Principles of interfacing
50
Digital Radiography Console Software ZView
51
Digital Radiography Console Software ZView
5.1.4. Sample
52