0% found this document useful (0 votes)
228 views20 pages

LV Motors Ie2 Safe Area Catalouge

The document discusses Bharat Bijlee IE2 induction motors that are efficient and suitable for a variety of industrial applications. It notes that Bharat Bijlee is a preferred brand across sectors due to its customized motor solutions, quality assurance processes, and pan-India service network. The document also provides information on Bharat Bijlee's history and milestones in developing efficient motor technologies, references relevant efficiency standards, and includes technical specifications for its IE2 safe area motor range.

Uploaded by

PRABHU SHANKAR M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
228 views20 pages

LV Motors Ie2 Safe Area Catalouge

The document discusses Bharat Bijlee IE2 induction motors that are efficient and suitable for a variety of industrial applications. It notes that Bharat Bijlee is a preferred brand across sectors due to its customized motor solutions, quality assurance processes, and pan-India service network. The document also provides information on Bharat Bijlee's history and milestones in developing efficient motor technologies, references relevant efficiency standards, and includes technical specifications for its IE2 safe area motor range.

Uploaded by

PRABHU SHANKAR M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

LV Motors: IE2 Safe Area

Reliable & Long Las ng

A MOTOR FOR EVERY NEED

July 2022
BHARAT BIJLEE MOTORS: MILESTONES

2018 Ultra Premium Energy Efficient


IE5 Motor:
Winner of CII’s Most Innovative
Energy Saving Product 2018
Super Premium Energy Efficient 2016
IE4 Motor:
Winner of CII’s Most Innovative
Energy Saving Product 2016
2013
MV Plant for
IC411 motors

2010
ToC journey begins

2009
LT range upto
400 frame

Own Sales & Marketing - 1990


Sales organisation
segmented geographically
1958-90
Marketing by Siemens
and its affiliates

Technical
1958
collaboration with
Siemens AG until 1981
1946
Started manufacturing
motors

2
LV Motors IE2: Safe Area

WHY BHARAT BIJLEE?

Preferred brand across mul ple sectors like


Cement, Construc on, Steel, Food & Beverages,
Water & Wastewater, and Sugar & Dis lleries,
to name a few.

Motors suited for all applica ons i.e. Pumps,


Compressors, Fans & Blowers, Conveyors, Li s,
Screen, Vibrators, Centrifuges, Stone Crusher,
and many more.

The most suitable solu ons for extremely harsh


and severe applica ons.

Customized motors designed and manufactured


to suit applica on-specific needs.

Motors conform to relevant IS/IEC standards.

Annual produc on capacity over 4,20,000


motors.

Supply chain based on the concept of ‘Theory of


Constraints’ ensures short lead mes, reliable
deliveries and superior availability.

Rigorous process control and quality assurance.

Pan India dealer and service network.

3
LV Motors IE2: Safe Area

The industrial sector accounts for over half of the total electricity Standards (MEPS) was voluntary. However, as per the recent
consump on, of which 60-70% is u lized by electric motors. mandate by the Government of India, the minimum efficiency
This indicates that electric motors consume more energy than of three phase squirrel cage induc on motors that can be
any other applica on. manufactured and sold in the country needs to be IE2 efficiency

A typical electric motor's average lifespan ranges anywhere level conforming to the IS standards.

between 15 to 20 years depending on the quality of raw material Bharat Bijlee has always advocated the concept of energy saving
and manufacturing process. The opera onal cost of a motor is for a sustainable future. It has always been our persistent endeavour
around 95% of the total life cycle cost. With a steadily increasing to develop a wide range of motors in the premium efficiency series,
installed base of electric motors, our na on has a tremendous thus rendering a choice to customers to select from the wide range
opportunity to save energy. of energy-efficient motors.

The purpose of energy efficiency labelling is to overcome the lack Established in 1946, Bharat Bijlee has evolved over the decades to
of awareness and also help end users in selec ng from a range of provide a wide range of motors suitable even for the most
energy-efficient products. While the developed world has kept severe of applica ons. Having gained the trust of our customers
pace with energy efficiency measures, developing countries over the years, we con nue to be the most preferred brand as
have been slower to implement them for electric motors. a result of our unique offering to the industry.

In the past, adhering to the Minimum Energy Performance

A MOTOR FOR EVERY NEED

4
LV Motors IE2: Safe Area

REFERENCE STANDARDS
IS 15999 Part 1 Three Phase Induc on Motor specifica ons (“Rota ng Electrical Machines - Part 1: Ra ng & Performance”)

IS : 900 Code of prac ce for installa on & maintenance of Induc on Motors

IS: 1231 Dimensions of foot mounted A.C Induc on Motors


IS: 2223 Dimensions of flange mounted A.C Induc on Motors

IS: 4029 Guide for tes ng of Three Phase Induc on Motors (For Standard TEFC SCR Motors)

IS: 4889 Methods of determina on of efficiency of Rota ng Electrical Machines (For Standard TEFC SCR Motors)

IS/IEC 60034-5 Degree of protec on provided by the integral design of Rota ng Electrical Machines (IP Code Classifica on)

IS: 6362/IEC 60034-6 Designa on of method of cooling for Rota ng Electrical Machines / Method of cooling (IC Code)

IS:12065/IEC 60034-9 Permissible limits of noise level for Rota ng Electrical Machines

IS : 12075 Mechanical Vibra on of Rota ng Electrical Machines

IS : 12615 Energy Efficient Induc on Motors Three Phase Squirrel Cage

IEC 60034-30 Rota ng Electrical Machines - Efficiency classes of line operated AC Motors (IE Code)

IEC 60072-1 Dimension & Output ra ng of Rota ng Electrical Machines

IS:15999 (Part 2/Sec 1) Standard Methods for determining losses and efficiency from tests (For IE Series Motors)

Compressor Conveyor

Pump Agitator

Separator Blower/Fan

Mixer Crusher

Screen Centrifuge

5
LV Motors IE2: Safe Area

MOUNTING ARRANGEMENT
Base refers to baseplate, founda on, slide rails, pedestal, etc.
Horizontal Moun ng

Schema c
Symbol Frame Moun ng
Diagram

B3
IMB3 / IM1001 With feet Mounted on base

B5
IMB5 / IM3001 Without feet Mounted on Type B flange with sha extension at flange end

B35
With feet Mounted on base with feet, and on Type B flange with sha extension at flange end
IMB35 / IM2001

B6
With feet Mounted on base to the wall; feet towards the le when viewed from DE side
IMB6 / IM1051

B7
IMB7 / IM1061 With feet Mounted on base to the wall; feet towards the right when viewed from DE side

B8
IMB8 / IM1071 With feet Mounted on base to the ceiling; feet at the top

B14
IMB14 / IM3601 Without feet Mounted on Type C flange with sha extension at flange end

Ver cal Moun ng

Symbol Schema c Moun ng


Frame
Diagram

V5
IMV5 / IM1011 With feet Mounted on base to the wall; sha downwards

V6
IMV6 / IM1031 With feet Mounted on base to the wall; sha upwards

V1
Without feet Mounted on Type B flange with sha extension at flange end; sha downwards
IMV1 / IM3011

V3
Without feet Mounted on Type B flange with sha extension at flange end; sha upwards
IMV3 / IM3031

V18
IMV18 / IM3611 Without feet Mounted on Type C flange with extension at flange end; sha downwards

V19
IMV19 / IM3631 Without feet Mounted on Type C flange with sha extension at flange end; sha upwards

6
LV Motors IE2: Safe Area

GENERAL TECHNICAL SPECIFICATIONS

Range
● Series: 3 Phase Squirrel Cage Induc on,
IE2 Safe Area Motors
● kW Ra ng: 0.12 to 355
● Frame: 56 to 355
● Polarity: 2, 4, 6 & 8

Standard Features Op onal Features


Voltage: 415V Any other voltage on request
Frequency: 50 Hz 60 Hz
IP55 IP56, IP65, IP66
B5, B35
B3 Moun ng
B14 (upto 132 Frame)
Ambient: 500C ; For DCCA motors: 400C Any other on request
Al tude: up to 1000 m above mean sea level Motors for higher al tudes on request
Top TB Any other on request
Aluminium Construc on: 56 to 132 Frame
Cast Iron construc on: 80 to 132 Frame
Cast Iron Construc on: 160 Frame & Above
Insula on: Class F Insula on: Class H
IC410: Natural Ven la on
IC411: Totally Enclosed Fan Cooled
IC416: Forced Cooling for 132 Frame & above
Sealed Bearing: upto 200 Frame
Online Greasing Arrangement: 160 to 200 Frame
Online Greasing Arrangement: 225 Frame & Above
Paint Shade: Acrylic base, RAL5000 Any other shade or material on request
Fan Cover: Steel
Duplex RTD: For DCCA Motors
Simplex & duplex RTD: 250 Frame & Above
Thermal Protec on in DCCA Motors: 3 nos. simplex RTD
BTD: 250 Frame & above
Thermister: 80 Frame & Above
Space Heater for DCCA Motors Space Heater: 90 Frame & Above
Inverter Duty Applica on: 315 Frame & Above Inverter Duty Applica on: Upto 280 Frame
Packing: Thermocol / Corrugated Boxes: Upto 132 Frame Wooden Pallets
Packing: Wooden Packing Boxes: 160 Frame & Above Seaworthy / Export Packing Case
Insulated Bearing / Hybrid Bearing: 132 frame & above
For standard bearings, kindly refer to the bearing chart Cylindrical Roller Bearing with Locking Arrangement on
DE Side : 160 frame & above

Our other op onal features:


● Higher polarity ● SS Hardware, Canopy, non standard paint & paint shade, cable gland
● Motors suitable for inverter duty applica on for all voltages ● Provision for hollow sha encoder moun ng
● Motors suitable for S2 to S9 duty opera on ● High temperature grease
● VPI upto 280 frame ● Reduced & Special grades of vibra on as per IS 12075 can be
● Non standard sha material, diameter & extension provided on request
● Front bearing locking arrangement

7
LV Motors IE2: Safe Area

RE-RATING FACTORS APPLICABLE UNDER DIFFERENT CONDITIONS OF


SUPPLY VOLTAGE, FREQUENCY, AMBIENT & ALTITUDE

I. Varia on in Supply Voltage & Frequency Star ng Current Measurement of Bharat Bijlee
Motors:
Combined Permissible
Voltage Frequency Induc on motor star ng current is generally 6 to 7 mes the
Voltage & Output as % of
Varia on % Varia on %
Frequency % Rated Value rated current of the motor. Star ng current measurement may
+ 10 +5 + 10 100 be carried out at reduced voltage due to capacity constraint and
+ 12.5 +5 + 12.5 95 then extrapolated to the rated voltage. At Bharat Bijlee, the star ng
+ 15 +5 + 15 90 current measurement is done at reduced voltage as per the
table below.

II. Varia on in Ambient


Measurement at % of
Permissible Output as kW Range voltage to rated voltage
Ambient Temperature ( C)
% of Rated Value
0.12kW to 90kW 70%
< 30 107
90kW to 200kW 60%
30 to 45 103
200kW to 355kW 35%
50 100
355kW to 560kW 25%
55 96
560kW and above (with rated
60 92 25%
voltage 690V or higher)

III. Varia on in Al tude


Bearing Chart
Al tude Above Permissible Output
Mean Sea Level (m) as % of Rated Value Bearing Nos.
Frame Size
1000 100 D.E. N.D.E.
1500 97 63 6201 2Z 6201 2Z
2000 94 71 6202 2Z 6202 2Z
2500 90 80 6004 2Z 6004 2Z
3000 86 90S & L 6205 2Z 6205 2Z
3500 82 100L 6206 2Z 6205 2Z
4000 77 112M 6206 2Z 6205 2Z
132S / M 6208 2Z 6208 2Z

Method of Star ng: 160M/L 6309 2Z 6209 2Z


180M/L 6310 2Z 6210 2Z
200L 6312 2Z 6212 2Z
kW Ra ng Method of Star ng No. of Leads
225S/M 6313 6213
Upto & including 1.5kW DOL 6 250M 6315 6215
Above 1.5kW DOL or Star / Delta 6 280S/M (2 Pole) 6316 6316
280S/M (4,6,8 Pole) 6317 6316
Number of Consecu ve Starts: 315S/M & L 6319 6319
For con nuous (S1) duty motors wherein load GD² ≤ Motor GD², the 355L 6322 6322
motors can safely withstand 3 consecu ve starts from cold condi on
& 2 consecu ve starts from hot condi on.

8
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615

Applicable standard for tes ng & efficiency determina on: IS15999


Voltage: 415V +/- 10% Ambient: 50°C Insula on: Class F
Frequency: 50Hz +/- 5% Duty: S1 (Con nuous) Temperature Rise: Class B
Combined Varia on: +/- 10% 3000 rpm (2 Pole) Protec on: IP55

Operating characteristics at rated output With DOL starting Net


Type Starting Starting Pullout Rotor Weight
Rated Output Rated Rated Rated
Reference Power Factor % Efficiency Current to Torque to Torque to GD² B3 constr.
Frame size Speed Current Torque
Rated Rated Rated
B3 Current Torque Torque
kW HP construction RPM Amps. kg- m FL 3/4L 1/2L FL 3/4L 1/2L Ratio kgm² kg
Ratio Ratio
0.18 0.25 63 2H063213AT000 2700 0.58 0.06 0.72 0.65 0.50 60.4 60.4 54.0 3.5 2.3 2.5 0.0005 4.5
0.25 0.35 63 2H063233AT000 2700 0.75 0.09 0.72 0.65 0.50 64.8 64.8 60.0 3.5 2.4 2.6 0.0006 5
0.37 0.50 71 2H0712A3AT000 2800 0.95 0.13 0.78 0.70 0.53 69.5 69.5 64.0 4.0 2.0 3.0 0.0012 6.8
0.55 0.75 71 2H071233AT000 2820 1.36 0.19 0.76 0.64 0.50 74.1 74.1 65.0 5.0 2.5 2.8 0.0016 7.7
0.75 1.0 80 2H080213AT000 2840 1.66 0.26 0.81 0.73 0.60 77.4 77.4 76.4 5.0 2.2 2.5 0.0026 10
1.1 1.5 80 2H080233AT000 2855 2.37 0.38 0.81 0.75 0.61 79.6 79.6 79.6 5.5 2.7 3.0 0.0034 11
1.5 2.0 90S 2H09S243AT000 2835 3.09 0.52 0.83 0.77 0.66 81.3 81.3 80.0 6.0 2.6 2.8 0.0053 15
2.2 3.0 90L 2H09L273AT000 2835 4.33 0.76 0.85 0.80 0.70 83.2 83.2 82.5 6.0 2.8 3.0 0.0066 17
3.7 5.0 100L 2H10L233AT000 2890 6.84 1.25 0.88 0.83 0.73 85.5 85.5 83.0 6.5 2.8 3.1 0.0142 24
5.5 7.5 132S 2H13S2G3AT000 2930 9.88 1.83 0.89 0.86 0.79 87.0 87.0 84.5 6.5 2.5 3.0 0.0515 47
7.5 10 132S 2H13S2N3AT000 2935 13.3 2.49 0.89 0.86 0.80 88.1 87.7 86.0 6.5 2.5 3.0 0.0800 59
9.3 12.5 160M 2H16M233CT000 2940 16.5 3.08 0.88 0.86 0.81 88.9 88.6 86.0 6.0 2.0 2.5 0.142 98
11 15 160M 2H16M253CT000 2940 19.5 3.64 0.88 0.85 0.79 89.4 89.4 87.0 6.5 2.1 2.6 0.160 104
15 20 160M 2H16M263CT000 2940 26.3 4.97 0.88 0.87 0.82 90.3 90.0 88.0 6.5 2.0 2.5 0.191 115
18.5 25 160L 2H16L293CT000 2940 31.5 6.13 0.90 0.89 0.86 90.9 90.9 89.0 6.5 2.0 2.5 0.244 137
22 30 180M 2H18M233CT000 2940 38.5 7.29 0.87 0.84 0.78 91.3 91.3 90.0 6.5 2.4 2.7 0.325 171
30 40 200L 2H20L2A3CT000 2950 51.6 9.91 0.88 0.86 0.80 92.0 92.0 90.5 6.5 2.6 3.0 0.524 259
37 50 200L 2H20L273CT000 2955 64.7 12.2 0.86 0.83 0.75 92.5 92.5 91.0 6.5 2.6 3.0 0.573 272
45 60 225M 2H22M253CT000 2965 77.5 14.8 0.87 0.85 0.80 92.9 92.9 91.5 6.5 2.3 2.4 1.04 365
55 75 250M 2H25M233CT000 2970 92.2 18.0 0.89 0.87 0.81 93.2 92.9 91.0 6.5 2.3 2.7 1.45 487
75 100 280S 2H28S23300000 2970 122 24.6 0.91 0.89 0.86 93.8 93.6 92.0 6.5 2.0 2.8 3.01 669
90 120 280M 2H28M25300000 2970 146 29.5 0.91 0.89 0.86 94.1 93.9 90.9 6.5 2.0 2.8 3.42 750
110 150 315S 2H31S23300000 2982 180 35.9 0.90 0.86 0.80 94.3 94.1 91.5 7.0 2.2 2.5 5.00 940
125 170 315M 2H31M2A300000 2982 207 40.8 0.89 0.85 0.78 94.5 93.5 91.5 7.0 2.2 2.6 5.00 940
132 180 315M 2H31M23300000 2982 216 43.1 0.90 0.86 0.80 94.6 93.6 91.3 7.0 2.0 2.5 5.00 940
150 200 315L 2H31L2A300000 2982 248 49.0 0.89 0.84 0.78 94.7 93.7 92.2 7.0 2.0 2.5 6.20 1100
160 215 315L 2H31L25300000 2985 261 52.2 0.90 0.86 0.80 94.8 94.1 93.0 7.0 2.4 2.5 6.20 1100
180 240 315L 2H31L2B300000 2982 300 58.8 0.88 0.82 0.75 94.9 94.1 93.0 7.0 2.0 2.5 7.70 1390
200 270 355L 2H35L2A300000 2985 325 65.3 0.90 0.87 0.82 95.0 94.2 92.2 7.0 1.6 2.4 12.0 1680
250 335 355L 2H35L21300000 2985 407 81.6 0.90 0.88 0.84 95.0 94.5 92.8 7.0 1.6 2.4 12.0 1680
315 425 355L 2H35L23300000 2985 513 103 0.90 0.88 0.84 95.0 94.5 93.0 7.0 1.6 2.4 14.7 1870

9
Note: All performance values are subject to tolerances as per IS 15999: Part-1
10
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615
Applicable standard for tes ng & efficiency determina on : IS15999
Voltage: 415V +/- 10% Ambient: 50°C Insula on: Class F
Frequency: 50Hz +/- 5% Duty: S1 (Con nuous) Temperature Rise: Class B
Combined Varia on: +/- 10% 1500 rpm (4 Pole) Protec on: IP55

Operating characteristics at rated output With DOL starting Net


Type Starting Starting Pullout Rotor Weight
Rated Output Rated Rated Rated
Reference Power Factor % Efficiency Current to Torque to Torque to GD² B3 constr.
Frame size Speed Current Torque
Rated Rated Rated
B3 Current Torque Torque
kW HP construction RPM Amps. kg- m FL 3/4L 1/2L FL 3/4L 1/2L Ratio kgm² kg
Ratio Ratio
0.12 0.16 63 2H063413AT000 1320 0.39 0.09 0.73 0.62 0.48 59.1 59.1 53.0 2.5 1.7 2.0 0.0010 4.5
0.18 0.25 63 2H063433AT000 1340 0.54 0.13 0.72 0.62 0.50 64.7 64.7 59.0 3.0 1.7 2.0 0.0013 5.5
0.25 0.35 71 2H0714A3AT000 1375 0.72 0.18 0.71 0.61 0.45 68.5 68.5 60.0 3.5 1.7 1.9 0.0022 6.8
0.37 0.50 71 2H071433AT000 1400 1.00 0.26 0.68 0.58 0.47 72.7 72.7 70.0 3.5 2.0 2.2 0.0031 8
0.55 0.75 80 2H080433AT000 1420 1.34 0.38 0.74 0.64 0.50 77.1 77.1 72.0 5.0 2.8 3.0 0.0066 10
0.75 1.0 80 2H080453AT000 1410 1.70 0.52 0.77 0.67 0.55 79.6 79.6 76.0 5.0 2.8 3.0 0.0073 11
1.1 1.5 90S 2H09S423AT000 1425 2.41 0.75 0.78 0.69 0.55 81.4 81.4 79.0 5.5 2.3 2.7 0.0097 14
1.5 2.0 90L 2H09L473AT000 1425 3.23 1.03 0.78 0.68 0.56 82.8 82.8 80.5 5.5 2.5 2.8 0.013 17
2.2 3.0 100L 2H10L473AT000 1425 4.37 1.50 0.83 0.74 0.60 84.3 84.3 82.5 6.0 2.6 3.0 0.021 24
3.7 5.0 112M 2H11M473AT000 1445 7.36 2.49 0.81 0.76 0.64 86.3 86.3 85.0 6.0 2.6 3.0 0.049 32
5.5 7.5 132S 2H13S4K3AT000 1450 10.4 3.69 0.84 0.81 0.67 87.7 87.7 86.0 6.5 2.2 2.8 0.103 48
7.5 10 132M 2H13M4T3AT000 1450 14.0 5.04 0.84 0.76 0.65 88.7 88.7 87.0 6.5 2.3 2.8 0.125 57
9.3 12.5 160M 2H16M4C3CT000 1465 17.6 6.18 0.82 0.76 0.68 89.4 89.4 87.0 6.5 2.4 2.7 0.187 99
11 15 160M 2H16M4K3CT000 1465 20.5 7.31 0.83 0.78 0.68 89.8 89.8 88.5 6.5 2.4 2.7 0.224 109
15 20 160L 2H16L4T3CT000 1465 27.8 10.0 0.83 0.78 0.68 90.6 90.6 89.5 6.5 2.4 2.7 0.293 132
18.5 25 180M 2H18M473CT000 1465 33.6 12.3 0.84 0.80 0.70 91.2 91.2 90.5 6.0 2.6 2.9 0.467 168
22 30 180L 2H18L483CT000 1465 39.3 14.6 0.85 0.82 0.72 91.6 91.6 91.0 6.5 2.6 2.9 0.532 187
30 40 200L 2H20L453CT000 1470 54.5 19.9 0.83 0.79 0.68 92.3 92.3 90.5 7.0 2.6 2.6 1.07 267
37 50 225S 2H22S433CT000 1470 65.3 24.5 0.85 0.82 0.75 92.7 92.7 91.0 6.0 2.3 2.4 1.41 330
45 60 225M 2H22M453CT000 1470 79.1 29.8 0.85 0.82 0.74 93.1 92.8 91.0 6.5 2.4 2.5 1.67 362
55 75 250M 2H25M433CT000 1480 96.3 36.2 0.85 0.82 0.74 93.5 93.5 92.5 6.5 2.5 2.7 2.95 500
75 100 280S 2H28S423CT000 1485 129 49.2 0.86 0.83 0.76 94.0 94.0 93.0 6.5 2.4 2.6 6.00 670
90 120 280M 2H28M453CT000 1485 155 59.0 0.86 0.82 0.76 94.2 94.2 93.5 6.5 2.3 2.8 6.87 725
110 150 315S 2H31S413CT000 1488 191 72.0 0.85 0.82 0.72 94.5 94.5 93.2 6.5 2.5 3.0 9.04 900
125 170 315M 2H31M4A3CT000 1488 216 81.8 0.85 0.80 0.73 94.7 94.4 93.5 6.8 2.25 2.75 10.7 970
132 180 315M 2H31M433CT000 1488 225 86.4 0.86 0.83 0.76 94.7 94.7 94.0 6.5 2.25 2.75 10.7 970
150 200 315L 2H31L4A3CT000 1487 259 98.3 0.85 0.83 0.76 94.9 94.7 94.0 6.8 2.5 3.0 13.3 1165
160 215 315L 2H31L453CT000 1487 273 105 0.86 0.84 0.78 94.9 94.9 94.0 6.5 2.4 3.0 13.3 1165
180 240 315L 2H31L463CT000 1488 307 118 0.86 0.84 0.78 95.0 95.0 94.5 6.5 2.4 3.0 14.9 1230
200 270 315L 2H31L473CT000 1489 336 131 0.87 0.84 0.78 95.1 95.1 94.0 6.5 2.4 3.0 17.0 1320
250 335 355L 2H35L41300000 1488 416 164 0.88 0.85 0.75 95.1 94.9 93.5 6.5 2.2 2.5 23.3 1680
315 425 355L 2H35L43300000 1488 524 206 0.88 0.85 0.75 95.1 94.8 93.5 6.5 2.2 2.5 32.7 1855
355 475 355L 2H35L45300000 1488 590 232 0.88 0.85 0.75 95.1 94.9 93.5 6.5 2.2 2.5 37.9 2186

Note: All performance values are subject to tolerance as per IS 15999: Part-1
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615

Applicable standard for tes ng & efficiency determina on : IS15999


Voltage: 415V +/- 10% Ambient: 50°C Insula on: Class F
Frequency: 50Hz +/- 5% Duty: S1 (Con nuous) Temperature Rise: Class B
Combined Varia on: +/- 10% 1000 rpm (6 Pole) Protec on: IP55

Operating characteristics at rated output With DOL starting Net


Type Starting Starting Pullout Rotor Weight
Rated Output Rated Rated Rated
Reference Power Factor % Efficiency Current to Torque to Torque to GD² B3 constr.
Frame size Speed Current Torque
Rated Rated Rated
B3 Current Torque Torque
kW HP construction RPM Amps. kg- m FL 3/4L 1/2L FL 3/4L 1/2L Ratio kgm² kg
Ratio Ratio
0.18 0.25 71 2H0716A3AT000 880 0.63 0.20 0.70 0.60 0.50 56.6 56.6 56.6 2.4 1.7 1.8 0.0033 7.2
0.25 0.35 71 2H071633AT000 860 0.78 0.28 0.72 0.62 0.50 61.6 61.6 61.6 2.6 1.8 1.9 0.0033 7.2
0.37 0.5 80 2H080613AT000 910 1.06 0.40 0.72 0.62 0.50 67.6 67.6 63.0 3.0 2.0 2.2 0.0054 8
0.55 0.75 80 2H080633AT000 910 1.45 0.59 0.72 0.63 0.50 73.1 73.1 70.0 3.5 2.1 2.3 0.0078 10
0.75 1.0 90S 2H09S633AT000 920 1.90 0.79 0.72 0.61 0.50 75.9 75.9 72.3 4.0 2.0 2.5 0.0105 14
1.1 1.5 90L 2H09L653AT000 920 2.72 1.16 0.72 0.61 0.50 78.1 78.1 74.0 4.0 2.0 2.5 0.0155 17
1.5 2.0 100L 2H10L633AT000 935 3.63 1.56 0.72 0.62 0.52 79.8 79.8 76.0 4.5 2.0 2.5 0.0241 22
2.2 3.0 112M 2H11M653AT000 955 5.00 2.24 0.75 0.65 0.56 81.8 81.8 79.8 5.5 2.1 2.5 0.0609 32
3.7 5.0 132S 2H13S6G3AT000 960 7.83 3.75 0.78 0.73 0.60 84.3 84.3 83.5 5.5 2.0 2.5 0.109 46
5.5 7.5 132M 2H13M6T3AT000 960 11.6 5.58 0.77 0.71 0.60 86.0 86.0 85.0 5.5 2.0 2.5 0.152 59
7.5 10 160M 2H16M633CT000 965 15.3 7.57 0.78 0.73 0.62 87.2 87.2 86.0 5.5 1.9 2.3 0.217 97
9.3 12.5 160L 2H16L663CT000 965 18.6 9.39 0.79 0.74 0.64 88.0 88.0 86.7 5.5 1.9 2.3 0.289 115
11 15 160L 2H16L673CT000 965 22.1 11.1 0.78 0.73 0.62 88.7 88.7 87.0 6.0 2.0 2.5 0.319 120
15 20 180L 2H18L633CT000 975 28.4 15.0 0.82 0.78 0.68 89.7 89.7 89.0 5.5 2.3 2.5 0.740 183
18.5 25 200L 2H20L633CT000 975 34.7 18.5 0.82 0.77 0.69 90.4 90.4 89.5 6.0 2.6 2.7 1.10 242
22 30 200L 2H20L653CT000 975 41.1 22.0 0.82 0.77 0.69 90.9 90.9 89.5 6.0 2.6 2.7 1.30 260
30 40 225M 2H22M643CT000 980 52.3 29.8 0.87 0.84 0.76 91.7 91.7 90.0 6.5 2.5 2.6 2.41 355
37 50 250M 2H25M633CT000 980 63.4 36.8 0.88 0.85 0.78 92.2 92.2 91.8 6.5 2.5 2.7 3.25 500
45 60 280S 2H28S613CT000 983 80.4 44.6 0.84 0.81 0.73 92.7 92.7 92.6 6.0 2.2 2.5 4.68 580
55 75 280M 2H28M633CT000 983 96.7 54.5 0.85 0.82 0.75 93.1 93.1 92.8 6.0 2.2 2.5 6.18 640
75 100 315S 2H31S613CT000 988 133 73.9 0.84 0.80 0.72 93.7 93.7 93.2 6.0 2.2 2.5 9.64 836
90 120 315M 2H31M633CT000 990 159 88.6 0.84 0.80 0.72 94.0 94.0 93.5 6.0 2.2 2.5 11.4 900
110 150 315M 2H31M653CT000 990 193 108 0.84 0.79 0.70 94.3 94.3 93.5 6.0 2.3 2.5 14.8 1021
125 170 315L 2H31L6A3CT000 990 222 123 0.83 0.79 0.70 94.5 94.5 93.5 6.5 2.2 2.5 17.3 1228
132 180 315L 2H31L673CT000 990 231 130 0.84 0.80 0.72 94.6 94.6 94.0 6.0 2.1 2.4 17.3 1228
150 200 315L 2H31L6B3CT000 993 265 147 0.83 0.79 0.70 94.7 94.7 94.4 6.0 2.2 2.5 20.4 1340
160 215 315L 2H31L693CT000 993 280 157 0.84 0.80 0.72 94.8 94.8 94.5 6.0 2.2 2.5 20.4 1340
180 240 355L 2H35L6A300000 990 322 177 0.82 0.77 0.65 94.9 94.6 93.3 6.0 2.0 2.5 28.7 1670
200 270 355L 2H35L61300000 990 349 197 0.84 0.80 0.70 95.0 94.7 93.5 6.0 2.0 2.5 28.7 1670
250 335 355L 2H35L63300000 990 436 246 0.84 0.80 0.70 95.0 94.7 93.4 6.0 2.0 2.5 35.5 1780

11
Note: All performance values are subject to tolerance as per IS 15999: Part-1
12
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615

Applicable standard for tes ng & efficiency determina on : IS15999


Voltage: 415V +/- 10% Ambient: 50°C Insula on: Class F
Frequency: 50Hz +/- 5% Duty: S1 (Con nuous) Temperature Rise: Class B
Combined Varia on: +/- 10% 750 rpm (8 Pole) Protec on: IP55

Operating characteristics at rated output With DOL starting Net


Type Starting Starting Pullout Rotor Weight
Rated Output Rated Rated Rated
Reference Power Factor % Efficiency Current to Torque to Torque to GD² B3 constr.
Frame size Speed Current Torque
Rated Rated Rated
B3 Current Torque Torque
kW HP construction RPM Amps. kg- m FL 3/4L 1/2L FL 3/4L 1/2L Ratio kgm² kg
Ratio Ratio
0.12 0.16 71 2H071833AT000 640 0.76 0.18 0.55 0.50 0.40 39.8 39.8 39.8 2.2 1.7 2.1 0.0033 7
0.18 0.25 80 2H080813AT000 675 0.91 0.26 0.60 0.52 0.42 45.9 45.9 40.0 3.0 1.8 2.2 0.0054 8
0.25 0.35 80 2H080833AT000 675 1.11 0.36 0.62 0.55 0.45 50.6 50.6 45.0 3.0 1.8 2.2 0.0078 10
0.37 0.50 90S 2H09S813AT000 680 1.30 0.53 0.71 0.58 0.46 56.1 56.1 53.0 2.8 1.7 2.1 0.0097 12
0.55 0.75 90L 2H09L853AT000 680 1.82 0.79 0.68 0.60 0.46 61.7 61.7 56.0 2.8 1.7 2.1 0.0129 14
0.75 1.0 100L 2H10L813AT000 685 2.25 1.07 0.70 0.61 0.50 66.2 66.2 66.2 3.0 1.9 2.3 0.0216 18
1.1 1.5 100L 2H10L833AT000 680 3.09 1.58 0.70 0.61 0.50 70.8 70.8 67.0 3.0 1.9 2.3 0.0271 20
1.5 2.0 112M 2H11M813AT000 695 4.00 2.10 0.70 0.61 0.49 74.1 74.1 71.0 3.8 1.7 2.2 0.0500 25
2.2 3.0 132S 2H13S8B3AT000 705 5.33 3.04 0.74 0.66 0.55 77.6 77.6 76.0 3.8 1.7 2.2 0.0911 41
3.7 5.0 160M 2H16M813CT000 715 8.55 5.04 0.74 0.68 0.55 81.4 81.4 80.0 4.4 1.7 2.2 0.202 87
5.5 7.5 160M 2H16M833CT000 715 12.2 7.49 0.75 0.68 0.55 83.8 83.8 82.5 4.4 1.7 2.2 0.291 101
7.5 10 160L 2H16L863CT000 715 16.3 10.2 0.75 0.70 0.58 85.3 85.3 84.0 4.4 1.8 2.3 0.376 119
9.3 12.5 180M 2H18M833CT000 725 19.5 12.5 0.77 0.74 0.64 86.3 86.3 85.0 5.0 1.7 2.1 0.705 170
11 15 180L 2H18L873CT000 725 22.9 14.8 0.77 0.74 0.64 86.9 86.9 86.0 5.0 1.8 2.2 0.813 187
15 20 200L 2H20L843CT000 725 28.9 20.2 0.82 0.77 0.65 88.0 88.0 87.0 5.5 2.3 2.5 1.37 264
18.5 25 225S 2H22S823CT000 725 35.4 24.9 0.82 0.80 0.72 88.6 88.6 87.6 5.5 2.0 2.2 2.11 324
22 30 225M 2H22M833CT000 725 41.9 29.6 0.82 0.80 0.72 89.1 89.1 88.1 5.5 2.0 2.2 2.41 351
30 40 250M 2H25M813CT000 730 56.7 40.0 0.82 0.80 0.72 89.8 89.8 89.0 5.5 2.0 2.2 3.25 498
37 50 280S 2H28S823CT000 730 73.1 49.4 0.78 0.74 0.65 90.3 90.3 90.0 5.5 2.0 2.2 6.18 641
45 60 280M 2H28M853CT000 738 90.8 59.4 0.76 0.72 0.60 90.7 90.7 90.5 5.5 2.0 2.2 7.25 690
55 75 315S 2H31S813CT000 739 112.1 72.5 0.75 0.72 0.62 91.0 91.0 90.5 5.5 1.8 2.0 9.6 836
75 100 315M 2H31M833CT000 739 154 98.8 0.74 0.70 0.62 91.6 91.6 91.0 5.5 1.8 2.0 11.4 900
90 120 315M 2H31M853CT000 741 179 118.3 0.76 0.72 0.64 91.9 91.9 91.5 5.5 1.8 2.0 14.8 1021
110 150 315L 2H31L873CT000 742 224 144.4 0.74 0.69 0.58 92.3 92.3 92.0 5.5 2.0 2.2 17.3 1228
125 170 315L 2H31L8A3CT000 742 247 164.1 0.76 0.70 0.60 92.5 92.5 92.0 5.5 2.0 2.2 21.5 1375
132 180 315L 2H31L893CT000 742 261 173.3 0.76 0.72 0.62 92.6 92.6 92.0 5.5 2.0 2.2 21.5 1375

Note: All performance values are subject to tolerance as per IS 15999: Part-1
LV Motors IE2: Safe Area

DIMENSIONAL DRAWING: IE2 EFFICIENCY SERIES FOR SAFE AREA APPLICATION


FOOT MOUNTED (IM B3/IM 1001) MOTORS AC
L 10 LV
AG
S2

d5 d5

FA
F

DA
B

HD
V
HC
D

A B

HA
H
GA GC
I I1
Sec on A-A BC Sec on B-B
AA K
BA BA1
E C B EA
B1 A
(For FS 280S/M & 315S/M)
BB AB

FIXING GENERAL TERMINAL BOX SHAFT

IEC Fr. AB BB AA BA BA1 BC HA HC HD S2 D* E* F* GA* I


Pole A* B* B1* C* H* K* L LV** AC V AG d5
Size BSC DA* EA* FA* GC* I1

63 2,4 100 80 — 40 63 7 126 100 28 30 — 10 7 125 179 206 30 124 149 40 1x 3/4" 11 23 4 12.5 18 M4
71 2,4,6&8 112 90 — 45 71 7 135 110 31 30 — 10 7 141 195 234 30 140 166 40 1x 3/4" 14 30 5 16 25 M5
80 2,4,6&8 125 100 — 50 80 10 150 124 31 35 — 12 9 159 214 267 30 157 185 40 1x 3/4" 19 40 6 21.5 35 M6
90S 2,4,6&8 100 125 302
140 — 56 90 10 168 34 31.5 — 13 12 177 230 35 174 199 52 2x 3/4" 24 50 8 27 45 M8
90L 2,4,6&8 125 150 327
100L 2,4,6&8 160 140 — 63 100 12 190 174 43.5 36 — 17 12 198 257 366 40 195 225 56 2x 1" 28 60 8 31 55 M10
112M 4,6&8 190 140 — 70 112 12 220 174 47 36 — 17 12 222 282 388 45 220 246 56 2x 1" 28 60 8 31 55 M10
2(7.5kW) 518
132S 2&4 140 180 50 475
6&8 216 — 89 132 12 256 54 — 20 16 262 328 459 50 260 291 63 2x1" 38 80 10 41 70 M12
4 513
132M 178 218 54
6 497
2(15kW) 635
160M 2 210 250 605
4,6&8 254 — 108 160 15 310 58 70 — 20 20 318 383 585 60 316 346 63 2x1" 42 110 12 45 105 M16
2&4 679
160L 254 294
6&8 629
180M 2,4&8 241 281 679
279 — 121 180 15 344 65 70 — 20 26 357 451 70 354 396 97 2x1 1/2" 48 110 14 51.5 100 M16
180L 4,6&8 279 319 717
2 795
200L 318 305 — 133 200 19 398 355 85 85 — 25 32 397 519 80 394 449 155 2x2" 55 110 16 59 100 M20
4,6&8 772
225S 4,8 286 336 827 60 140 18 64 130
2 356 — 149 225 19 436 85 85 — 25 34 450 568 837 90 445 500 155 2x2" 55 110 16 59 100 M20
225M 311 361
4,6&8 855 60 140 18 64 130
2 60 140 18 64 130
250M 406 349 — 168 250 24 506 425 100 115 — 46 42 495 665 914 100 489 578 243 2x2" M20
4,6&8 65 140 18 69 130
2 65 140 18 69 130
280S/M 457 368 419 190 280 24 540 490 100 110 149 37 42 552 725 1010 115 544 638 243 2x 2" M20
4,6&8 75 140 20 79.5 130
2 1175 65 140 18 69 130
315S/M 406 457 540 155 2x2"
4,6&8 1167 80 170 22 85 160 M20
508 216 315 28 625 120 120 43 45 617 834 130 604 728 278
2 1340 65 140 18 69 130
315L 508 — 593 — 2x2 1/2"
4,6&8 1332 90 170 25 95 160 M24
2 1461 75 140 20 79.5 130 M20
355L 4(355kW) 610 630 — 254 355 28 710 770 110 170 — 70 45 703 939 1575 145 695 850 403 2x3"
100 210 28 106 200 M24
4&6 1531

Notes: * This is a mandatory dimension for all standard motors Notes: 1. Eyebolt is not provided in motors of 63 to 90 frame
**Minimum distance for efficient cooling of motor to be maintained by user 2. Sha extension at NDE iden cal to standard sha extension at DE is not
1. All dimensions are in mm unless otherwise specified possible in 4, 6 & 8 pole in frames 315L & 355L
2. Tolerances on mandatory dimensions are as per IS: 1231 3. TB Posi on: To be read as: when viewed from DE side / when viewed parallel
3. For non standard motors, dimensions may change. Please contact our to the sha / cable entry
nearest sales office for details (a) 63 frame, 160 to 225 frame: Top / Center of body / RHS when viewed from
DE side
(b) 71 to 132 frame & 250 to 355 frame: Top / Towards Drive End / RHS when
viewed from DE side

13
LV Motors IE2: Safe Area

DIMENSIONAL DRAWING: IE2 EFFICIENCY SERIES FOR SAFE AREA APPLICATION


FLANGE MOUNTED (IM B5/IM3001) MOTORS

L 10 LV
AG
S2
LA
T

d5

AD
d5

45°

V
F

D1

FA
A B

AC
N
D
P

22.5°
A B M
I I1

45°
GA GC

Sec on A-A Sec on B-B 8- Drilled holes


4- Drilled holes S
for FS 225-FS 355
E EA for FS 63-FS 200

FIXING GENERAL TERMINAL BOX SHAFT


IEC Fr. D* E* F* GA* I
Size Pole P* N* M* S* T* LA* AD L LV** AC V AG S2 BSC d5
DA* EA* FA* GC* I1

63 2,4 140 95 115 23 10 3 9 116 225 30 124 86 40 1x3/4" 11 23 4 12.5 18 M4


71 2,4,6&8 160 110 130 30 10 3.5 9 124 262 30 140 95 40 1x3/4" 14 30 5 16 25 M5
80 2,4,6&8 200 130 165 40 12 3.5 10 134 267 30 157 105 40 1x3/4" 19 40 6 21.5 35 M6
90S 2,4,6&8 302
200 130 165 50 12 3.5 10 140 35 174 109 52 2x3/4" 24 50 8 27 45 M8
90L 2,4,6&8 327
100L 2,4,6&8 250 180 215 60 15 4 11 157 366 40 195 125 56 2x1" 28 60 8 31 55 M10
112M 4,6&8 250 180 215 60 15 4 11 170 388 45 220 134 56 2x1" 28 60 8 31 55 M10
2(7.5kW) 518
132S 2&4 475
6&8 300 230 265 80 15 4 12 196 459 50 260 159 63 2x1" 38 80 10 41 70 M12
4 513
132M
6 497
2(15kW) 635
160M 2 605
4,6&8 350 250 300 110 19 5 13 223 585 60 316 186 63 2x1" 42 110 12 45 105 M16
2&4 679
160L
6&8 629
180M 2,4&8 679
350 250 300 110 19 5 13 271 70 354 216 97 2x1 1/2" 48 110 14 51.5 100 M16
180L 4,6&8 717
2 795
200L 400 300 350 110 19 5 15 319 80 394 249 155 2x2" 55 110 16 59 100 M20
4,6&8 772
225S 4&8 140 827 60 140 18 64 130
2 450 350 400 110 19 5 16 343 837 90 445 275 155 2x2" 55 110 16 59 100 M20
225M
4,6&8 140 855 60 140 18 64 130
2 60 140 18 64 130
250M 550 450 500 140 19 5 18 415 914 100 489 328 243 2x2" M20
4,6&8 65 140 18 69 130
2 65 140 18 69 130
280S/M 550 450 500 140 19 5 18 445 1010 115 544 358 243 2x2" M20
4,6&8 75 140 20 79.5 130
2 140 1175 65 140 18 69 130
315S/M 2x2"
4,6&8 170 1167 80 170 22 85 160 M20
660 550 600 24 6 22 519 130 604 413 278
2 140 1340 65 140 18 69 130
315L 2x2 1/2"
4,6&8 170 1332 90 170 25 95 160 M24
2 140 1461 75 140 20 79.5 130 M20
355L 4(355kW) 800 680 740 24 6 25 584 1575 145 695 495 403 2x3"
210 100 210 28 106 200 M24
4&6 1531

Notes: * This is a mandatory dimension for all standard motors Notes: 1. Eyebolt is not provided in motors of 63 to 90 frame
**Minimum distance for efficient cooling of motor to be maintained by user 2. Sha extension at NDE iden cal to standard sha extension at DE is not
1. All dimensions are in mm unless otherwise specified possible in 4, 6 & 8 pole in frames 315L & 355L
2. Tolerances on mandatory dimensions are as per IS: 2223 3. TB Posi on: To be read as: when viewed parallel to the sha / cable
3. For non standard motors, dimensions may change. Please contact our entry
nearest sales office for details (a) 63 frame, 160 to 225 frame: Center of body / RHS when viewed from
DE side
(b) 71 to 132 frame & 250 to 355 frame: Towards Drive End / RHS when
viewed from DE side

14
LV Motors IE2: Safe Area

DIMENSIONAL DRAWING: IE2 EFFICIENCY SERIES FOR SAFE AREA APPLICATION


FACE MOUNTED (IM B14/IM 3601) MOTORS

L 10 LV
AG
S2

T ENLARGEMENT
OF CIRCLE ‘A’

AD
V
45°
d5 d5
F

DA

FA
A B
N

AC
P

A B M
I

45°
GA I1 GC
Tapped Holes
Sec on A-A ‘A’ Sec on B-B
E EA S

FIXING GENERAL TERMINAL BOX SHAFT


IEC Fr. AD L AC V AG S2 BSC D* E* F* GA* I
Size Pole P* N* M* S* T* LV** d5
DA* EA* FA* GC* I1

63 2,4 90 60 75 23 M5X10 2.5 116 206 30 124 86 40 1x3/4" 11 23 4 12.5 18 M4


71 2,4,6&8 105 70 85 30 M6X10 2.5 124 235 30 140 95 40 1x3/4" 14 30 5 16 25 M5
80 2,4,6&8 120 80 100 40 M6X13 3 134 267 30 157 105 40 1x3/4" 19 40 6 21.5 35 M6
90S 2,4,6&8 302
140 95 115 50 M8X12 3 140 35 174 109 52 2x3/4" 24 50 8 27 45 M8
90L 2,4,6&8 327
100L 2,4,6&8 160 110 130 60 M8X12 3.5 157 366 40 195 125 56 2x1" 28 60 8 31 55 M10
112M 4,6&8 160 110 130 60 M8X12 3.5 170 388 45 220 134 56 2x1" 28 60 8 31 55 M10

Notes: * This is a mandatory dimension for all standard motors Notes: 1. Eyebolt is not provided in motors of 63 to 90 frame
**Minimum distance for efficient cooling of motor to be maintained by user 2. For the dimensional drawing of 132 frame, B14 moun ng kindly contact
1. All dimensions are in mm unless otherwise specified our nearest sales office
2. Tolerances on mandatory dimensions are as per IS: 2223 3. TB Posi on: To be read as: when viewed parallel to the sha / cable entry
3. For non standard motors, dimensions may change. Please contact our (a) 63 frame: Center of body / RHS when viewed from DE side
nearest sales office for details (b) 71 to 112 frame: Towards Drive End / RHS when viewed from DE side

15
LV MOTORS PRODUCT RANGE
Motors conform to relevant Indian Standards IS/IEC 60034 series
Voltage: 415V +/- 10%, Frequency: 50 Hz +/- 5%, Combined Varia on: +/- 10%
Motor Type Frame Power (kW) Polarity Standard Technical Specifica ons

IE2 Motors 56 to 355 0.12 to 355 2, 4, 6, 8


● Ambient: 50° C
● Ambient for DCCA: 40° C
● Inverter Grade Winding: For IE3 and DCCA
IE3 Motors 56 to 355 0.12 to 355 2, 4, 6, 8
● Duty: S1
● RTD & BTD: For DCCA motors
● Moun ng: B3, B5, B35, V1, B14 upto 132 Frame
Large LT Motors (DCCA) 355 to 450 250 to 1250 2, 4, 6, 8

● Ambient: 50° C
● Inverter Duty Winding
IE4 Motors 112 to 225 1.5 to 45 4 ● Duty: S1
● VPI: With Class H solvent less Resin
● Moun ng: B3, B5, B35, V1

Standard Flame Proof Ex'd' Motors 80 to 315 0.37 to 200 2, 4, 6, 8

● Ambient: 45° C
IE2 Flame Proof Ex'd' Motors 80 to 315 0.37 to 200 2, 4, 6, 8 ● Inverter Grade Winding: For IE3 Motors
● Duty: S1
● Moun ng: B3, B5, B35, V1
IE3 Flame Proof Ex'd' Motors 80 to 315 0.37 to 180 2, 4, 6, 8

IE2 Increased Safety Ex ec Motors 63 to 355 0.12 to 355 2, 4, 6, 8


● Ambient: 50° C
● Duty: S1
● Moun ng: B3, B5, B35, V1 (B14 upto 132 Frame)
IE3 Increased Safety Ex ec Motors 63 to 355 0.12 to 355 2, 4, 6, 8

● Ambient: 45° C
● Duty: S4
Crane & Hoist Duty Motors 71 to 355 0.37 to 400 4, 6, 8
● Offered in DOL & Converter Fed Supply
● Moun ng: B3, B5, B35, V1 (B14 upto 132 Frame)

● Ambient: 50° C
Brake Motors ● Duty: S1
71 to 132 0.25 to 9.3 2, 4, 6, 8
(With Integral DC Brake) ● Moun ng: B3, B5, B35
● Integral DC Brake

● Ambient: 50° C
Brake Motors ● Duty: S1
71 to 200 0.37 to 22 2, 4, 6, 8
(With External Mounted Brake) ● Moun ng: B3, B5, B35
● External Mounted DC Brake/Arrangement

● Ambient: 45° C
Slip Ring Motors 100 to 160 1.1 to 10 4, 6 ● Duty: S3, S4, S5
● Moun ng: B3

● Ambient: 50° C
Tex le Motors 100 to 160 1.1 to 15 4, 6, 8 ● Duty: S1
● Moun ng: B3, B5, B35

● Ambient: 45° C
● Start/Stop per Hour: upto 900
● Duty: S5, 50% CDF
Cane Unloader Motors 160 to 225 11 to 30 6 ● Thermostat
● Moun ng: B3, B5, B35
● Forced Cooling
● Sha Material: En24

16 * Subject to confirma on from Bharat Bijlee


Insula on: Class 'F' with temperature rise limited to Class 'B', Rota on: Bi-direc onal
Cooling: IC411, Degree of Protec on: IP55, Al tude: Upto 1000m above MSL
Op onal Features Applica ons

● Non Standard Voltage: upto 690V


● Higher Polarity on request ● High Temperature Grease: Suitable up to 200° C
Pump, Fan, Compressor, Packing Machinery,
● Insula on: Class H ● SS Hardware
Coiler/De-coiler, Agro Equipment,
● Space Heater: 90 Frame onwards ● Non standard sha diameter/extension*
Food Processing Equipment, Paper Machinery,
● RTD & BTD: 250 Frame onwards ● Non Standard Paint
Agitator, Dairy Equipment, Machine Tool,
● PTC Thermistor: 80 to 355L ● Provision for Encoder Moun ng
Air Condi oning, Material Handling,
● Sha Material: EN24* ● Low Vibra on as per IS or IEC
Plas c Machinery, Tex le Machinery,
● Enclosure: IP56 / 65 / 66 ● Insulated Bearing: 132 Frame onwards
Cooling Tower, Crusher, Material Handling
● Forced Cooling: 132 to 450 Frame ● SPM Nipples Provision: Frame 250 onwards
● Roller Bearing: 160 Frame onwards

● Insula on: Class H


● Space Heater: 90 Frame onwards ● Non standard sha diameter/extension*
● PTC Thermistor: 80 to 225 Frame ● Non Standard Paint
Fans, HVAC, Pumps, Tex les, Hydraulic Press
● Sha Material: EN24* ● Provision for Encoder Moun ng
● Enclosure: IP56 / 65 / 66 ● Low Vibra on as per IS or IEC
● Roller Bearing: 160 Frame onwards

● Non Standard Voltage: 220 to 690V ● Insulated Bearing: 132 Frame onwards
● Intermi ent Duty S3, S4: In 4, 6, 8 Pole* ● Non standard sha diameter/extension* Pump, Fan, Compressor,
● Insula on: Class H ● Motors for inverter duty applica on ; offered with Material Handling, Agitator,
● PTC Thermistor: 80 to 315 L ● Combined tes ng of motor and VFD or LPG Bo ling Plant,
● Space Heater: 90 Frame onwards ● Motors fi ed with PTC Thermistor Pharma Machinery,
● Roller Bearing: 160 Frame onwards ● Test facility available for combined Tes ng with VFD Chemical Plant Machinery,
● Sha Material: EN24* ● Non Standard Paint Machinery for Mines
● Enclosure: IP56 / 65 / 66 ● Low Vibra on as per IS or IEC

● Insulated Bearing: 132 Frame onwards


● Non standard sha diameter/extension*
● Insula on: Class H
● Motors for inverter duty applica on with combined tes ng Pump, Fan, Compressor,
● Sha Material: EN24*
of motor and VFD for temperature class cer fica on Material Handling, Agitator,
● Enclosure: IP56 / 65 / 66
● Test facility available for combined tes ng with VFD Pharma Machinery
● Roller Bearing: 160 Frame onwards
● Non Standard Paint
● Low Vibra on as per IS or IEC

● Duty: S2, S3 and S5


● Non Standard Voltage: 380 to 460V
● Insula on: Class H ● Motors for Inverter Duty
Crane, Hoist, Li ,
● Space Heater: 90 Frame onwards ● Insulated Bearing: 132 Frame onwards
Material Handling,
● BTD: 250 Frame and above ● Non standard sha diameter/extension*
Car Stacker,
● PTC Thermistor: 80 to 355 L ● Non Standard Paint
Door Opening
● Roller Bearing: 160 Frame onwards ● Low Vibra on as per IS or IEC
● Sha Material: EN24*
● Enclosure: IP56 / 65 / 66

● Duty: S2 and above


● Non Standard Voltage: upto 460V
● Non standard sha diameter/extension* Crane, Hoist, Material Handling, Tex le,
● Motors for Inverter Duty
● Non Standard Paint Pharma to name a few
● Manual Release Arrangement: For 90 to
132 Frame

● Duty: S2 and above


● Non Standard Voltage: upto 460V ● Double Sha Extension for Brake Arrangement Crane, Hoist, Material Handling,
● Motors for Inverter Duty ● Non Standard Paint Tex le, Pharma to name a few
● Manual Release Arrangement

● Moun ng: B35


● Non Standard Paint Crane, Hoist, Li , Material Handling
● Non standard sha diameter and extension*

● Motors for Inverter Duty


● Non Standard Voltage: upto 500V Ginning, Tex le Machinery
● Non Standard Paint
● Insula on: Class H
● Low Vibra on as per IS

● Insula on: Class H ● Insulated Bearing: 132 Frame onwards


Cane Loading-Unloading Machine
● PTC Thermistor ● Non Standard Paint

17
LV Motors IE2: Safe Area

CERTIFICATIONS

Super Premium Energy Efficient Ultra Premium Energy Efficient


IE4 Motor: IE5 Motor:
Winner of CII’s Most Innovative Winner of CII’s Most Innovative
Energy Saving Product 2016 Energy Saving Product 2018

New Product Upcoming Product

ISO 9001 : 2015 ISO 45001:2018 ISO 14001 : 2015

18
MOTOR, DRIVE AND AUTOMATION SOLUTIONS

Visualisation & HMI

Controls

Drives

Motors

Bharat Bijlee’s Industrial Systems product portfolio caters to a spectrum of applications and
spans the machine automation pyramid.

19
ALL INDIA SERVICE NETWORK
Regional Offices

Works

Authorised Service Centre: Motors


Amritsar
Service Centre: Servo Motors
Ludhiana
Mohali

Saharanpur
Faridabad
Panipat
Rudrapur
Gurugram
New Delhi
Bhiwadi, Alwar
Noida Tinsukia
Jaipur

Ajmer Kanpur
Guwahati
Beawar Patna

Udaipur Rewa

Gandhidham Katni Purba Burdwan


Ahmedabad Bhopal Jabalpur Hooghly
Korba
Jamnagar Mandideep
Baroda Indore Bilaspur
Rajkot Ankleshwar Ramgarh
Bharuch Kolkata
Surat Nagpur Raipur Jamshedpur
Vapi Bhilai
Nashik Rourkela

Mumbai Ahmednagar Bhuvaneshwar

Pune
Visakhapatnam
Kolhapur
Vijaywada
REGIONAL OFFICES
Mumbai +91 22 6145 7200
Secunderabad
Guntur Pune +91 74100 11271 / 72
Goa
Ahmedabad +91 79 6604 9200
Belgaum
New Delhi +91 11 2581 6931 / 6932 / 6933
Hubli
Indore +91 731 2524 474 / 2514 486
Bengaluru Ludhiana +91 161 2775 692 / 93
Chennai
Salem Jaipur +91 141 2377 223
Veppadai Puducherry
Kolkata +91 33 24432383 / 2467 ; +91 33 4062 3076 / 3077
Calicut Erode
Coimbatore Bengaluru +91 80 2559 2646 / 2137 / 2681
Madurai Chennai +91 44 2815 4794 / 4793
Kochi Secunderabad +91 40 2780 1791 / 2781 4512
Coimbatore +91 422 4204314

For any enquiries please write to [email protected]

+91 22 - 2763 7290 | [email protected]


With effect from July 2022

Customer Service Helpdesk for Industrial Systems

REGISTERED OFFICE WORKS


Electric Mansion, 6th Floor, No. 2, MIDC Thane-Belapur Road, Airoli,
Appasaheb Marathe Marg, Navi Mumbai 400 708
Prabhadevi, Mumbai 400 025 T: +91 22 2763 7200 / +91 22 2760 0401
M/C/2SA/3/0722/0000

T: +91 22 2430 6237 / 6375


E: [email protected]
CIN: L31300MH1946PLC005017 www.bharatbijlee.com

Product improvement is a continuous process and technical information herein is subject to change.

You might also like