2
LV Motors IE2: Safe Area
3
LV Motors IE2: Safe Area
The industrial sector accounts for over half of the total electricity Standards (MEPS) was voluntary. However, as per the recent
consump on, of which 60-70% is u lized by electric motors. mandate by the Government of India, the minimum efficiency
This indicates that electric motors consume more energy than of three phase squirrel cage induc on motors that can be
any other applica on. manufactured and sold in the country needs to be IE2 efficiency
A typical electric motor's average lifespan ranges anywhere level conforming to the IS standards.
between 15 to 20 years depending on the quality of raw material Bharat Bijlee has always advocated the concept of energy saving
and manufacturing process. The opera onal cost of a motor is for a sustainable future. It has always been our persistent endeavour
around 95% of the total life cycle cost. With a steadily increasing to develop a wide range of motors in the premium efficiency series,
installed base of electric motors, our na on has a tremendous thus rendering a choice to customers to select from the wide range
opportunity to save energy. of energy-efficient motors.
The purpose of energy efficiency labelling is to overcome the lack Established in 1946, Bharat Bijlee has evolved over the decades to
of awareness and also help end users in selec ng from a range of provide a wide range of motors suitable even for the most
energy-efficient products. While the developed world has kept severe of applica ons. Having gained the trust of our customers
pace with energy efficiency measures, developing countries over the years, we con nue to be the most preferred brand as
have been slower to implement them for electric motors. a result of our unique offering to the industry.
4
LV Motors IE2: Safe Area
REFERENCE STANDARDS
IS 15999 Part 1 Three Phase Induc on Motor specifica ons (“Rota ng Electrical Machines - Part 1: Ra ng & Performance”)
IS: 4029 Guide for tes ng of Three Phase Induc on Motors (For Standard TEFC SCR Motors)
IS: 4889 Methods of determina on of efficiency of Rota ng Electrical Machines (For Standard TEFC SCR Motors)
IS/IEC 60034-5 Degree of protec on provided by the integral design of Rota ng Electrical Machines (IP Code Classifica on)
IS: 6362/IEC 60034-6 Designa on of method of cooling for Rota ng Electrical Machines / Method of cooling (IC Code)
IS:12065/IEC 60034-9 Permissible limits of noise level for Rota ng Electrical Machines
IEC 60034-30 Rota ng Electrical Machines - Efficiency classes of line operated AC Motors (IE Code)
IS:15999 (Part 2/Sec 1) Standard Methods for determining losses and efficiency from tests (For IE Series Motors)
Compressor Conveyor
Pump Agitator
Separator Blower/Fan
Mixer Crusher
Screen Centrifuge
5
LV Motors IE2: Safe Area
MOUNTING ARRANGEMENT
Base refers to baseplate, founda on, slide rails, pedestal, etc.
Horizontal Moun ng
Schema c
Symbol Frame Moun ng
Diagram
B3
IMB3 / IM1001 With feet Mounted on base
B5
IMB5 / IM3001 Without feet Mounted on Type B flange with sha extension at flange end
B35
With feet Mounted on base with feet, and on Type B flange with sha extension at flange end
IMB35 / IM2001
B6
With feet Mounted on base to the wall; feet towards the le when viewed from DE side
IMB6 / IM1051
B7
IMB7 / IM1061 With feet Mounted on base to the wall; feet towards the right when viewed from DE side
B8
IMB8 / IM1071 With feet Mounted on base to the ceiling; feet at the top
B14
IMB14 / IM3601 Without feet Mounted on Type C flange with sha extension at flange end
V5
IMV5 / IM1011 With feet Mounted on base to the wall; sha downwards
V6
IMV6 / IM1031 With feet Mounted on base to the wall; sha upwards
V1
Without feet Mounted on Type B flange with sha extension at flange end; sha downwards
IMV1 / IM3011
V3
Without feet Mounted on Type B flange with sha extension at flange end; sha upwards
IMV3 / IM3031
V18
IMV18 / IM3611 Without feet Mounted on Type C flange with extension at flange end; sha downwards
V19
IMV19 / IM3631 Without feet Mounted on Type C flange with sha extension at flange end; sha upwards
6
LV Motors IE2: Safe Area
Range
● Series: 3 Phase Squirrel Cage Induc on,
IE2 Safe Area Motors
● kW Ra ng: 0.12 to 355
● Frame: 56 to 355
● Polarity: 2, 4, 6 & 8
7
LV Motors IE2: Safe Area
I. Varia on in Supply Voltage & Frequency Star ng Current Measurement of Bharat Bijlee
Motors:
Combined Permissible
Voltage Frequency Induc on motor star ng current is generally 6 to 7 mes the
Voltage & Output as % of
Varia on % Varia on %
Frequency % Rated Value rated current of the motor. Star ng current measurement may
+ 10 +5 + 10 100 be carried out at reduced voltage due to capacity constraint and
+ 12.5 +5 + 12.5 95 then extrapolated to the rated voltage. At Bharat Bijlee, the star ng
+ 15 +5 + 15 90 current measurement is done at reduced voltage as per the
table below.
8
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615
9
Note: All performance values are subject to tolerances as per IS 15999: Part-1
10
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615
Applicable standard for tes ng & efficiency determina on : IS15999
Voltage: 415V +/- 10% Ambient: 50°C Insula on: Class F
Frequency: 50Hz +/- 5% Duty: S1 (Con nuous) Temperature Rise: Class B
Combined Varia on: +/- 10% 1500 rpm (4 Pole) Protec on: IP55
Note: All performance values are subject to tolerance as per IS 15999: Part-1
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615
11
Note: All performance values are subject to tolerance as per IS 15999: Part-1
12
LV MOTORS: IE2 SAFE AREA
Performance Data: Efficiency Values Complying to IE2 Efficiency Class of IS12615
Note: All performance values are subject to tolerance as per IS 15999: Part-1
LV Motors IE2: Safe Area
d5 d5
FA
F
DA
B
HD
V
HC
D
A B
HA
H
GA GC
I I1
Sec on A-A BC Sec on B-B
AA K
BA BA1
E C B EA
B1 A
(For FS 280S/M & 315S/M)
BB AB
63 2,4 100 80 — 40 63 7 126 100 28 30 — 10 7 125 179 206 30 124 149 40 1x 3/4" 11 23 4 12.5 18 M4
71 2,4,6&8 112 90 — 45 71 7 135 110 31 30 — 10 7 141 195 234 30 140 166 40 1x 3/4" 14 30 5 16 25 M5
80 2,4,6&8 125 100 — 50 80 10 150 124 31 35 — 12 9 159 214 267 30 157 185 40 1x 3/4" 19 40 6 21.5 35 M6
90S 2,4,6&8 100 125 302
140 — 56 90 10 168 34 31.5 — 13 12 177 230 35 174 199 52 2x 3/4" 24 50 8 27 45 M8
90L 2,4,6&8 125 150 327
100L 2,4,6&8 160 140 — 63 100 12 190 174 43.5 36 — 17 12 198 257 366 40 195 225 56 2x 1" 28 60 8 31 55 M10
112M 4,6&8 190 140 — 70 112 12 220 174 47 36 — 17 12 222 282 388 45 220 246 56 2x 1" 28 60 8 31 55 M10
2(7.5kW) 518
132S 2&4 140 180 50 475
6&8 216 — 89 132 12 256 54 — 20 16 262 328 459 50 260 291 63 2x1" 38 80 10 41 70 M12
4 513
132M 178 218 54
6 497
2(15kW) 635
160M 2 210 250 605
4,6&8 254 — 108 160 15 310 58 70 — 20 20 318 383 585 60 316 346 63 2x1" 42 110 12 45 105 M16
2&4 679
160L 254 294
6&8 629
180M 2,4&8 241 281 679
279 — 121 180 15 344 65 70 — 20 26 357 451 70 354 396 97 2x1 1/2" 48 110 14 51.5 100 M16
180L 4,6&8 279 319 717
2 795
200L 318 305 — 133 200 19 398 355 85 85 — 25 32 397 519 80 394 449 155 2x2" 55 110 16 59 100 M20
4,6&8 772
225S 4,8 286 336 827 60 140 18 64 130
2 356 — 149 225 19 436 85 85 — 25 34 450 568 837 90 445 500 155 2x2" 55 110 16 59 100 M20
225M 311 361
4,6&8 855 60 140 18 64 130
2 60 140 18 64 130
250M 406 349 — 168 250 24 506 425 100 115 — 46 42 495 665 914 100 489 578 243 2x2" M20
4,6&8 65 140 18 69 130
2 65 140 18 69 130
280S/M 457 368 419 190 280 24 540 490 100 110 149 37 42 552 725 1010 115 544 638 243 2x 2" M20
4,6&8 75 140 20 79.5 130
2 1175 65 140 18 69 130
315S/M 406 457 540 155 2x2"
4,6&8 1167 80 170 22 85 160 M20
508 216 315 28 625 120 120 43 45 617 834 130 604 728 278
2 1340 65 140 18 69 130
315L 508 — 593 — 2x2 1/2"
4,6&8 1332 90 170 25 95 160 M24
2 1461 75 140 20 79.5 130 M20
355L 4(355kW) 610 630 — 254 355 28 710 770 110 170 — 70 45 703 939 1575 145 695 850 403 2x3"
100 210 28 106 200 M24
4&6 1531
Notes: * This is a mandatory dimension for all standard motors Notes: 1. Eyebolt is not provided in motors of 63 to 90 frame
**Minimum distance for efficient cooling of motor to be maintained by user 2. Sha extension at NDE iden cal to standard sha extension at DE is not
1. All dimensions are in mm unless otherwise specified possible in 4, 6 & 8 pole in frames 315L & 355L
2. Tolerances on mandatory dimensions are as per IS: 1231 3. TB Posi on: To be read as: when viewed from DE side / when viewed parallel
3. For non standard motors, dimensions may change. Please contact our to the sha / cable entry
nearest sales office for details (a) 63 frame, 160 to 225 frame: Top / Center of body / RHS when viewed from
DE side
(b) 71 to 132 frame & 250 to 355 frame: Top / Towards Drive End / RHS when
viewed from DE side
13
LV Motors IE2: Safe Area
L 10 LV
AG
S2
LA
T
d5
AD
d5
45°
V
F
D1
FA
A B
AC
N
D
P
22.5°
A B M
I I1
45°
GA GC
Notes: * This is a mandatory dimension for all standard motors Notes: 1. Eyebolt is not provided in motors of 63 to 90 frame
**Minimum distance for efficient cooling of motor to be maintained by user 2. Sha extension at NDE iden cal to standard sha extension at DE is not
1. All dimensions are in mm unless otherwise specified possible in 4, 6 & 8 pole in frames 315L & 355L
2. Tolerances on mandatory dimensions are as per IS: 2223 3. TB Posi on: To be read as: when viewed parallel to the sha / cable
3. For non standard motors, dimensions may change. Please contact our entry
nearest sales office for details (a) 63 frame, 160 to 225 frame: Center of body / RHS when viewed from
DE side
(b) 71 to 132 frame & 250 to 355 frame: Towards Drive End / RHS when
viewed from DE side
14
LV Motors IE2: Safe Area
L 10 LV
AG
S2
T ENLARGEMENT
OF CIRCLE ‘A’
AD
V
45°
d5 d5
F
DA
FA
A B
N
AC
P
A B M
I
45°
GA I1 GC
Tapped Holes
Sec on A-A ‘A’ Sec on B-B
E EA S
Notes: * This is a mandatory dimension for all standard motors Notes: 1. Eyebolt is not provided in motors of 63 to 90 frame
**Minimum distance for efficient cooling of motor to be maintained by user 2. For the dimensional drawing of 132 frame, B14 moun ng kindly contact
1. All dimensions are in mm unless otherwise specified our nearest sales office
2. Tolerances on mandatory dimensions are as per IS: 2223 3. TB Posi on: To be read as: when viewed parallel to the sha / cable entry
3. For non standard motors, dimensions may change. Please contact our (a) 63 frame: Center of body / RHS when viewed from DE side
nearest sales office for details (b) 71 to 112 frame: Towards Drive End / RHS when viewed from DE side
15
LV MOTORS PRODUCT RANGE
Motors conform to relevant Indian Standards IS/IEC 60034 series
Voltage: 415V +/- 10%, Frequency: 50 Hz +/- 5%, Combined Varia on: +/- 10%
Motor Type Frame Power (kW) Polarity Standard Technical Specifica ons
● Ambient: 50° C
● Inverter Duty Winding
IE4 Motors 112 to 225 1.5 to 45 4 ● Duty: S1
● VPI: With Class H solvent less Resin
● Moun ng: B3, B5, B35, V1
● Ambient: 45° C
IE2 Flame Proof Ex'd' Motors 80 to 315 0.37 to 200 2, 4, 6, 8 ● Inverter Grade Winding: For IE3 Motors
● Duty: S1
● Moun ng: B3, B5, B35, V1
IE3 Flame Proof Ex'd' Motors 80 to 315 0.37 to 180 2, 4, 6, 8
● Ambient: 45° C
● Duty: S4
Crane & Hoist Duty Motors 71 to 355 0.37 to 400 4, 6, 8
● Offered in DOL & Converter Fed Supply
● Moun ng: B3, B5, B35, V1 (B14 upto 132 Frame)
● Ambient: 50° C
Brake Motors ● Duty: S1
71 to 132 0.25 to 9.3 2, 4, 6, 8
(With Integral DC Brake) ● Moun ng: B3, B5, B35
● Integral DC Brake
● Ambient: 50° C
Brake Motors ● Duty: S1
71 to 200 0.37 to 22 2, 4, 6, 8
(With External Mounted Brake) ● Moun ng: B3, B5, B35
● External Mounted DC Brake/Arrangement
● Ambient: 45° C
Slip Ring Motors 100 to 160 1.1 to 10 4, 6 ● Duty: S3, S4, S5
● Moun ng: B3
● Ambient: 50° C
Tex le Motors 100 to 160 1.1 to 15 4, 6, 8 ● Duty: S1
● Moun ng: B3, B5, B35
● Ambient: 45° C
● Start/Stop per Hour: upto 900
● Duty: S5, 50% CDF
Cane Unloader Motors 160 to 225 11 to 30 6 ● Thermostat
● Moun ng: B3, B5, B35
● Forced Cooling
● Sha Material: En24
● Non Standard Voltage: 220 to 690V ● Insulated Bearing: 132 Frame onwards
● Intermi ent Duty S3, S4: In 4, 6, 8 Pole* ● Non standard sha diameter/extension* Pump, Fan, Compressor,
● Insula on: Class H ● Motors for inverter duty applica on ; offered with Material Handling, Agitator,
● PTC Thermistor: 80 to 315 L ● Combined tes ng of motor and VFD or LPG Bo ling Plant,
● Space Heater: 90 Frame onwards ● Motors fi ed with PTC Thermistor Pharma Machinery,
● Roller Bearing: 160 Frame onwards ● Test facility available for combined Tes ng with VFD Chemical Plant Machinery,
● Sha Material: EN24* ● Non Standard Paint Machinery for Mines
● Enclosure: IP56 / 65 / 66 ● Low Vibra on as per IS or IEC
17
LV Motors IE2: Safe Area
CERTIFICATIONS
18
MOTOR, DRIVE AND AUTOMATION SOLUTIONS
Controls
Drives
Motors
Bharat Bijlee’s Industrial Systems product portfolio caters to a spectrum of applications and
spans the machine automation pyramid.
19
ALL INDIA SERVICE NETWORK
Regional Offices
Works
Saharanpur
Faridabad
Panipat
Rudrapur
Gurugram
New Delhi
Bhiwadi, Alwar
Noida Tinsukia
Jaipur
Ajmer Kanpur
Guwahati
Beawar Patna
Udaipur Rewa
Pune
Visakhapatnam
Kolhapur
Vijaywada
REGIONAL OFFICES
Mumbai +91 22 6145 7200
Secunderabad
Guntur Pune +91 74100 11271 / 72
Goa
Ahmedabad +91 79 6604 9200
Belgaum
New Delhi +91 11 2581 6931 / 6932 / 6933
Hubli
Indore +91 731 2524 474 / 2514 486
Bengaluru Ludhiana +91 161 2775 692 / 93
Chennai
Salem Jaipur +91 141 2377 223
Veppadai Puducherry
Kolkata +91 33 24432383 / 2467 ; +91 33 4062 3076 / 3077
Calicut Erode
Coimbatore Bengaluru +91 80 2559 2646 / 2137 / 2681
Madurai Chennai +91 44 2815 4794 / 4793
Kochi Secunderabad +91 40 2780 1791 / 2781 4512
Coimbatore +91 422 4204314
Product improvement is a continuous process and technical information herein is subject to change.