0% found this document useful (0 votes)
701 views1 page

Flat Slab Details A1

The document appears to be a technical drawing showing reinforcement details for a concrete slab. It includes a top view of the slab with measurements and callouts for rebar sizes and spacing. The drawing specifies the type and configuration of rebar mesh and bars to be used under different slab widths.

Uploaded by

Viktoria Yumang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
701 views1 page

Flat Slab Details A1

The document appears to be a technical drawing showing reinforcement details for a concrete slab. It includes a top view of the slab with measurements and callouts for rebar sizes and spacing. The drawing specifies the type and configuration of rebar mesh and bars to be used under different slab widths.

Uploaded by

Viktoria Yumang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A

200
1 200

660

660
1197

537

537
OD

13800
OD

TOP VIEW PLAN FFL


H10-200 0.075L/0.125L PLACED ALTERNATELY
*SLAB TOPPING REINF'T SCALE 1:20 OR 600(MIN)

75
6H16 (TOP BAR) (BY OTHERS AT SITE)

A
600 W (MAX. 600) 600 MESH *SLAB TOPPING REINF'T
0.33L1 OR 600(MIN) MESH (BY OTHERS AT SITE)
SFL FOR TOP BAR: SFL
TA W=400-500: USE 5H25

75
W=300-400: USE 4H25
75

313
W=200-300: USE 3H16

360

360

HCS
W=100-200: USE 2H16 MESH
300
HCS

SLAB SFL

5
150

75
B B B B B B A A A A A A A A
HCS HCS

47

47
40
TA
HCS
6H16 (BOTTOM BAR)

A, B
OD
NIB DETAILS TO
CONSULTANT'S DESIGN
H10-200 40 140 40 140 40 140 40 140 40 140 40 140 40
39 39 NOTE:
60 MAX. BEAM/WALL

FOR BOTTOM BAR: FOR LINKS: A, B 1. L = Length of HCS


NOTE: W=400-500: USE 5H25 W=300-500: USE H13-100 OPEN LINKS 1197
1. TOP & BOTTOM BARS TO BE ANCHORED TO MAIN BEAM. W=300-400: USE 4H25 W=100-300: USE H13-150 OPEN LINKS OD

2. TA = TENSION ANCHORAGE W=200-300: USE 3H25


3. L1 - LENGTH OF SLAB W=100-200: USE 2H25 SECTION A-1 WALL SUPPORTING HCS
SCALE 1:7 SCALE 1:15
POUR STRIP DETAILS NOTE:
BETWEEN HCS & BEAM / WALL 1. TOP & BOTTOM BARS TO BE ANCHORED TO MAIN BEAM.
SCALE 1:30
POUR STRIP DETAILS BETWEEN HCS
Cover 25mm to wire mesh
SCALE 1:30 or topping reinforcement 02 03
07 06
DETAIL "A" 01
02 03 SFL
SMALL OPENING & SERVICES
WITHIN SHADED AREA ONLY 07
(SUBJECT TO ENGINEER'S APPROVAL) 01
SFL
HCS THK.

HCS

PRESTRESSED TENDONS 05
(NO CUTTING) 04 05 04
1200
HCS WIDTH
01 TOPPING 05 JOINT GROUT
NOTE:
DETAIL "A"
TEMPLATE FOR SMALL FLOOR
02 WIRE MESH 06 SLAB TOPPING REINF'T AT SPECIFIED AREAS 1. Use 25 Poker Vibrator to compact concrete properly in joints.
OPENING AND INSTALLATION OF
SERVICES 03 CONCRETE SPACER 07 H10-600 AT EVERY SLAB JOINT (TYPICAL)
2. Jointing & Topping, Topping up to beams and casting of R.C. slabs 3D VIEW
to be done in one operation to avoid any joints in the topping SCALE NTS
SCALE 1:15 between topping & R.C. member. Surface to be power trowelled.
04 PRESTRESSED PRECAST HOLLOW CORE SLAB

TYPICAL JOINT DETAIL OF HOLLOW CORE SLAB


SCALE NTS

IN THE OFFICE OF: SUBJECT: STUDENT: PROJECT OWNER: PROJECT TITLE: REMARKS: SHEET CONTENTS: SHEET NO.:

DRAWN BY: CHECKED BY: APPROVED:


BUILDING TECHNOLOGY 5 VIKTORIA ALLONA M. YUMANG
(C-PCBT 5)
DEPARTMENT: YEAR AND SECTION:
NGOC HUYEN FLAT SLAB DETAILS FLAT SLAB DETAILS V.A.M. YUMANG J.E.D. DELA CRUZ

INSTRUCTOR: ARCHITECTURE DEPARTMENT - CEA BS-ARCH 4A

ARCH. JOSEPH EDWARD D. DELA CRUZ SCHOOL: UNIVERSITY OF THE ASSUMPTION LOCATION: DATE SUBMITTED: AUGUST 22, 2022