Zenbo Paper Bag 1260S-450C Electrical Diagram
Zenbo Paper Bag 1260S-450C Electrical Diagram
ZB1260S-450
Electrical drawing
B16 B17 B18 A6 A10 A5
B19 B20
B4
B2 B12 B23 A7
B26 B27
S47 B6 A8
B8
B1 B7
B5
B10 B38
A9
B21,B22 B13 B14 B15 A12 B25
B9 A4 A3 A11
S48,S49
S51,S52
B34 B30 B32
B28,B29 B36
B35 B31 B33 S55,S56
1 2 3 4 5 6 7 8 9 10
N
2-46-1
F1
L1
6
03-2
L2
4
03-2
L3
2
03-2
3P/N/PE
40A
QF1
380V
50HZ 10mm^2
T3
L3
Power wire: 10 mm^2 03-1
T2
L2
Short circuit protection: 40A 03-1
T1
L1
03-1
QF6 1 3 5 QF7 1 3 5
14-2
KM1
QF5 1 3 5
4-6.3A 4-6.3A
5.79A
17-23A
16A 5.5A
I I I I I I
I I I
2 4 6 2 4 6
2 4 6
2.5mm^2
QF100 1 3 5
T1 L1 L2 L3 L1 L2 L3
R/L1 S/L2 T/L3
PE KM3 KM4
ATV320U75N4B LC1D12M7C LC1D12M7C
0.63-1A 7.5KW frequency transformer 11-7 11-4
T1 T2 T3 T1 T2 T3
1A
10 65
64
2 4 6 1.5mm^2
65
6
1mm^2 2.5mm^2
27-6
K2
64
65
11
7
31-2
K18
64
12
QF21
8
1 3 5
31-2
K18
25-3
25-3
PE
17-23A
W2
U2
V2
I I I
W3
U3
V3
2 4 6
PE
03-1
PE
W1
U1
V1
PE
PE
U V W PE
M2
U V W PE
KTV3.8
5.79A M M3
2.2KW T4.40 DSK
5.5A M
PE
U V W PE U V W PE
M1 1.85KW
M 15.6A M
7.5KW
02-4
REVISION
main circuit 0
0 2017/4/14 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
02
1 2 3 4 5 6 7 8 9 10
02-9 04-1
02-9 04-1
02-9 04-1
02-6 04-2
02-6 04-2
02-6 04-2
I I I I I I I I I I I I I I I
2 4 6 2 4 6 2 4 6 2 4 6 2 4 6
L1 L2 L3 L1 L2 L3 L1 L2 L3
L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3
KM9 KM10 KM11
LC1D12M7C LC1D12M7C LC1D12M7C
KM5 KM6 KM7 KM8 11-5 11-5 11-6
LC1D12M7C LC1D12M7C LC1D12M7C LC1D12M7C T1 T2 T3 T1 T2 T3 T1 T2 T3
12-6 12-6 12-9 12-8
T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3
W4
W4
W5
W5
V4
V4
V5
V5
W5
U4
U4
U5
U5
1.5mm^2 1.5mm^2 1.5mm^2
V5
U4 U5
1.5mm^2 1.5mm^2
PE
02-9 04-2
W4
U4
V4
W5
U5
V5
PE
W6
PE
PE
PE
U6
V6
W8
W8
U7
U8
V7
V8
PE
U V W PE U V W PE U V W PE U V W PE U V W PE
M4 M5 M6 M7 M8
RV40/75-300-Y03.7-1314-F-VS1
1.12A M RV40/75-300-Y03.7-1314-F-VS1
1.12A M VT4.40
3.4A M T4.40 DSK
5.5A M T4.40 DSK
5.5A M
0.37KW 0.37KW 1.25KW 1.85KW 1.85KW
REVISION
main circuit 0
0 2017/4/14 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
03
1 2 3 4 5 6 7 8 9 10
03-6
03-6
03-6
03-10
03-10
03-10
QF17 1 3 5
2.5-4A 2.5-4A 1 3 I I I
3.4A 2.5A QF18 0.63-1A 17-23A
10mm^2 2 4 6 0.67A 17A
I I I I I I 10A
I I I I I I
2 4 6 2 4 6
2 4 2 4 6 2 4 6
L1 L2 L3
KM16
LC1D18M7C L1 L2 L3
L1 L2 L3 L1 L2 L3 11-7 L1 L2 L3
T1 T2 T3 KM15
KM12 KM13 1.5mm^2 KM14 LC1D12M7C
LC1D12M7C LC1D12M7C T2 LC1D12M7C 11-8
13-6 13-4 0 13-7 T1 T2 T3
T1 T2 T3 T1 T2 T3 0 0 05-1 T1 T2 T3
R16
T16
1
S16
1-A
05-1
2
400 PE 230
1.5mm^2 1.5mm^2
10A
Q1
1mm^2 4mm^2
2-46-1
2-46-1
2-46-1
PE
W10
U10
V10
W9
U9
V9
PE
03-10 05-1
W11
U11
R15
V11
T15
S15
PE
PE
PE
PE
U V W PE U V W PE U V W PE U V W PE
M9 M11 M12 M13
VT4.40
3.4A M DF-08
2.5A M GLW18Y63(I:5)
0.67A M MESA 6 ,4 H/G
17A M
1.25KW 1.1KW 0.2KW 3kw
REVISION
main circuit 0
0 2017/4/15 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
04
1 2 3 4 5 6 7 8 9 10
1-A 2 2
04-6 06-6
4
20A
S45
2 310
14-1
9
K18 DRM570024L
K18
31-2
2 2+
10
12-1
DRM570024L
31-2
2
11-1
1.5mm^2
16A
24V PE
Q2
2 24V 24V
N
06-1
2
0V
0V
06-1
L
SMPS
A1
2-46-9
0
04-6 12-1
PE
04-10 13-1
REVISION
transformer drawing 0
0 2017/5/8 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
05
1 2 3 4 5 6 7 8 9 10
24V
05-10 07-1
0V
05-10 07-1
24V
05-10
0V
6
K24
2 2
24-8
DRM570024L
10
0V
KM23 A1 S33 S34 S39 13 23 33
XPSAF5130
K1
XPS-AF LOGIC K2
3 3
S32 S32
20A 20A
4 4
44
3 3
0V
S33 S33
20A 20A
211
311
4 4
3 3
S40 S40
20A 20A
07-5
07-5
26-4
4 4
3 3
S41 S41
20A 20A
4 4
3 3
S42 S42
K8
1 9 20A 20A
4 4
2 10 3 3
3 11
S43 S43
4 12 20A 20A
4 4
5 9 12-7 3 3
S65 S65
6 10
20A 20A
7 11 4 4
3 3
8 12
S66 S66
S9
20A
S64
20A 20A
K8
4 4
0V
2-56-8
14
13
3
REVISION
E-stop 0
0 2017/5/8 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
06
1 2 3 4 5 6 7 8 9 10
24V
06-10 09-2
0V 0V
06-10 08-1
06-6
06-6
5
K24
0V
24-8
DRM570024L
311
211
9
K1
XPS-AF LOGIC K2
5 5
K35 K36
X40
212
312
23-6 23-6
9 9
08-1
08-1
29-7
REVISION
safety module(door swith) 0
0 2017/8/5 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
07
1 2 3 4 5 6 7 8 9 10
212
07-5
0V
07-10 09-2
206
09-2
15-6
15-6
16-6
16-6
17-6
17-6
312
07-5
212
202 204
光+1
光+2
光+3
光-1
光-2
光-3
206
10
10
10
9
9
202
K1
K1
K1
K2
K2
K2
KM17 KM18 KM19
SG4-00VA000RS SG4-00VA000RS SG4-00VA000RS
201 safety relay 203 safety relay 205 safety relay
4
7
1
1
0V 0V 0V
15
15
15
12
12
12
14
14
14
3
8
2
2
312 301 302 303 304 305 306
09-3
X15
09-2
REVISION
safety module(light guard) 0
0 2017/5/6 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
08
1 2 3 4 5 6 7 8 9 10
206 208
08-10 10-2
0V
08-10 10-2
19-6
19-6
206
光+5
光-5
0V
0V
10
9
K1
K2
KM24
SG4-00VA000RS
207 safety relay
7
1
0V 0V
15
12
X15
08-9
14
8
2
X15
14
2-55-3
K37
24V
07-10 10-2
K37
1 9 28-8
2 10
3 11
4 12
5 9
6 10
7 11
8 12
REVISION
safety module(light guard) 0
0 2017/11/18 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
09
1 2 3 4 5 6 7 8 9 10
24V
09-9 15-1
0V 0V
09-9 15-1
208 2+
09-9 12-1
18-6
18-6
光+4
光-4
2+
0V
10
9
208
K1
K2
KM20
SG4-00VA000RS
209 safety relay
6
1
7
0V
15
12
X41
29-7
14
8
2
REVISION
safety module(light guard) 0
0 2017/8/2 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
10
1 2 3 4 5 6 7 8 9 10
2
05-10
2
2
2
2
5
K14
31-6 A1 A1
DRM570024L KM16 KM15
5
9 K19
32-3
DRM570024L A2 A2
5 5
K1 K4 9
27-5 27-8
DRM570024L DRM570024L
9 9
122
108
160
160
160
112
A1
KM3
A1 A1 A1
KM9 KM10 KM11
A1
108
108
108
A2
KM4
A2 A2 A2
A2
L L L
H1 H2 H3
alarm alarm alarm
N N N
0
0
0
0
0
0
21 22 21 22 21 22 21 22 21 22 21 22 21 22
REVISION
220V controlling electrical drawing 0
0 2017/9/4 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
11
1 2 3 4 5 6 7 8 9 10
2+
10-9 13-1
2+
2+
2+
2+
2+
05-10
1
K2
2+
1 1 1 1
27-6
K6 K7 DRM570024L K10 K11
30-3 30-4 9 30-8 30-8
DRM570024L DRM570024L DRM570024L DRM570024L
9 9 9 9
115
113
119
117
2+
2+
5 5 5 5 5 5
K7 K6 K8 K9 K11 K10
30-4 30-3 06-3 30-7 30-8 30-8
DRM570024L DRM570024L DRM570024L DRM570024L DRM570024L DRM570024L
9 9 9 9 9 9
116
114
120
118
A1 A1 A1 A1
KM6 KM5 KM8 KM7
A2 A2 A2 A2
L L
0
Motor Motor
0
L L
fan fan
M16
180W M M22
180W M
M17
M M18
M
0.14A 0.14A
N N
N N
0
0
0
0
05-10 13-1
KM6 KM5 KM8 KM7
L1 T1 03-3 L1 T1 03-2 L1 T1 03-5 L1 T1 03-4
L2 T2 03-3 L2 T2 03-2 L2 T2 03-5 L2 T2 03-4
L3 T3 03-3 L3 T3 03-2 L3 T3 03-5 L3 T3 03-4
13 14 13 14 13 14 13 14
21 22 21 22 21 22 21 22
REVISION
220V controlling electrical drawing 0
0 2017/4/15 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
12
1 2 3 4 5 6 7 8 9 10
2+
12-10 25-1
2+
2+
2+
2+
5
K22
37-4
DRM570024L
5 5 5
K15 K20 K21 9
31-7 32-4 32-5
DRM570024L DRM570024L DRM570024L
R22
9 9 9
153
124
A1
KM14
J10
A2
A1 A1
KM13 KM12
A2 A2
L
Motor
M10
180W M
N
0
0
12-10 14-1
PE
05-10 15-1
21 22 21 22 21 22
REVISION
220V controlling electrical drawing 0
0 2017/4/15 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
13
1 2 3 4 5 6 7 8 9 10
310 310
05-10
310
310
10-9
A1
KM1 KM2
A2
0
0
13-10 25-1
KM1
L1 T1 02-3
L2 T2 02-3
L3 T3 02-3
13 14
21 22
REVISION
220V controlling electrical drawing 0
0 2017/5/5 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
14
1 2 3 4 5 6 7 8 9 10
Receiver Transmitter
A3
A4 SEMG618
SEMG518
OSSD1
EDM
OSSD2
24V
Signal
RES
0V
E2
E1
PE
24V
0V
PE
光+1
光-1
08-3
08-3
24V
0V
PE
24V
0V
PE
24V 24V
10-9 16-1
0V
10-9 16-1
PE
13-10 16-1
REVISION
light guard 0
0 2017/5/6 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
15
1 2 3 4 5 6 7 8 9 10
Receiver Transmitter
A5
A6 SEMG616
SEMG516
OSSD1
EDM
OSSD2
24V
Signal
RES
0V
E2
E1
PE
24V
PE
0V
光+2
光-2
08-5
08-6
24V
PE
24V
0V
PE
0V
24V
15-10 17-1
0V
15-10 17-1
PE
15-10 17-1
REVISION
light guard 0
0 2017/5/6 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
16
1 2 3 4 5 6 7 8 9 10
Receiver Transmitter
A7
A8 SEMG616
SEMG416
OSSD1
EDM
OSSD2
24V
Signal
RES
0V
E2
E1
PE
24V
0V
PE
光+3
光-3
08-8
08-8
24V
0V
PE
24V
0V
PE
24V
16-10 18-1
0V
16-10 18-1
PE
16-10 18-1
REVISION
light guard 0
0 2017/5/6 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
17
1 2 3 4 5 6 7 8 9 10
Receiver Transmitter
A9
A10 SEMG433.
SEMG433
OSSD1
EDM
24V
OSSD2
Signal
RES
0V
E2
E1
PE
24V
PE
0V
24V
0V
光+4
光-4
24V
0V
10-4
10-4
PE
PE
24V
17-10 19-1
0V
17-10 19-1
PE
17-10 19-1
REVISION
light guard 0
0 2017/8/2 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
18
1 2 3 4 5 6 7 8 9 10
Receiver Transmitter
A11
A12 SEMG618
SEMG518
OSSD1
EDM
OSSD2
24V
Signal
RES
0V
E2
E1
PE
24V
0V
PE
光+5
光-5
09-3
09-4
0V
24V
PE
24V
0V
PE
24V 24V
18-10 20-1
0V
18-10 20-1
PE
18-10 25-1
REVISION
light guard 0
0 2017/11/18 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
19
1 2 3 4 5 6 7 8 9 10
24V
19-10 21-1
24V
24V
24V
24V
5 5 5 5 6
K12 K13 K16 K17 K19
5 5 5 6 31-4 31-4 31-7 31-8 32-3
K2 K3 K5 K5 DRM570024L DRM570024L DRM570024L DRM570024L DRM570024L
27-6 27-8 30-2 30-2
DRM570024L DRM570024L DRM570024L DRM570024L 9 9 9 9 10
9 9 9 10
132
133
609
610
166
616
605
145
143
145
145
145
solenoid valve solenoid valve
143
143
143
0V 0V 0V 0V 0V 0V
X1 X1 X1
X1 X1 X1
S4 S29 S39
S3 S28 S38 24-6 24-6 24-7
X2 X2 X2
24-4
X2 X2 X2
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
19-10 21-1
REVISION
24V controlling electrical drawing 0
0 2017/4/15 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
20
1 2 3 4 5 6 7 8 9 10
24V
20-10 22-1
24V
24V
24V 24V 24V 24V 24V 24V 24V 24V 24V
B9 B2 B4 B12 B13 B14 B15 B16 B17
proximity switch proximity switch photosensor 2000 P/R encoder NPN photosensor NPN photosensor NPN photosensor proximity switch proximity switch
0V OUT 0V 152 OUT 0V OUT OUT A 0V OUT B 0V OUT 0V OUT 0V OUT 0V OUT 0V OUT
75
50
72
72
71
63
60
76
36-6
25-5
25-6
25-6
25-9
26-3
26-7
33-7
33-8
0V
0V
0V
0V
0V
0V
0V
0V
0V
gluing photo sensor
handle gluing on
auto gluing on
0V
20-10 22-1
REVISION
24V controlling electrical drawing 0
0 2017/4/15 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
21
1 2 3 4 5 6 7 8 9 10
24V
21-10 23-1
24V 24V 24V 24V 24V 24V 24V 24V 24V 24V
B18 B19 B20 B21 B22 B23 B24 B25 B26 B27
proximity switch proximity switch proximity switch proximity switch beam photoelectric switch
proximity switch proximity switch proximity switch proximity switch
0V OUT 0V OUT 0V OUT 0V OUT 0V OUT 0V OUT 0V 0V OUT 0V OUT 0V OUT
163
151
61
54
70
55
56
24V 24V
Y7 Y8
26-7
25-6
33-3
29-8
26-6
29-9
33-2
solenoid valve solenoid valve
0V 0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
21-10 23-1
REVISION
24V controlling electrical drawing 0
0 2017/4/16 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
22
1 2 3 4 5 6 7 8 9 10
0V
22-10 24-1
0V 3
4
3
4
3
4
0V
3
4
3
4
3
4
S10
S18
S24
S25
S30
S31
S46
13 13
K35 K36
14 14
24V
22-10 24-1
K35 K36
1 9 1 9
2 10 2 10
3 11 3 11
4 12 4 12
5 9 07-3 5 9 07-4
6 10 6 10
7 11 7 11
8 12 8 12
REVISION
24V controlling electrical drawing 0
0 2017/9/4 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
23
1 2 3 4 5 6 7 8 9 10
0V
23-10 25-1
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
0V
3 3 3 3 3 3 3 3 3 3 3 3 3
S2 S14 S27 S37 S3 S15 S28 S38 S4 S16 S29 S39 S1 S13 S26 S36
42
42
42
43
43
43
43
45
45
45
45
41
41
41
41
machine inch mode
42
43
45
41
13
K24
paper feeding
machine run 14
25-7
25-8
26-2
28-6
warning
24V
23-10 25-1
K24
1 9
2 10
3 11
4 12
5 9 07-3
6 10 06-4
7 11
8 12
REVISION
24V controlling electrical drawing 0
0 2017/4/16 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
24
1 2 3 4 5 6 7 8 9 10
24V
24-9 27-2
0
14-10
PE
19-10
2+
13-10
21-5
21-6
21-7
22-5
24-3
24-4
21-8
72
72
163
50
42
43
71
72
L PE N S/S X0 X1 X2 X3 X4 X5
26-2
N1
Mitsubishi
FX3GA-60MR
Mitsubishi PLC
gluing photosensor
machine run
encoder A phase
0V
24-9 26-1
REVISION
N1-PLC input 0
0 2017/4/21 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
25
1 2 3 4 5 6 7 8 9 10
0V
25-10 28-1
24-6
21-9
06-7
22-8
21-9
22-2
0V
0V
0V
0V
3 1 3
S19 S21 S47 S48
20A
4 3 4
45
63
44
70
60
61
80
81
92
90
X6 X7 X10 X11 X12 X13 X14 X15 X16 X17
25-2 28-2
N1
Mitsubishi
FX3GA-60MR
manual paper pallet down Mitsubishi PLC
auto gluing ON
E-stop
handle gluing ON
auto handle ON
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
26
1 2 3 4 5 6 7 8 9 10
29-2 30-2
13 13 13 13
K1 K2 K3 K4
14 14 14 14
24V
25-10 30-1
0V
29-10 30-1
K1 K2 K3 K4
1 9 1 9 12-7 1 9 1 9
2 10 2 10 2 10 2 10
3 11 3 11 3 11 3 11
4 12 4 12 4 12 4 12
7 11 7 11 7 11 7 11
8 12 8 12 8 12 8 12
REVISION
N1-PLC output 0
0 2017/4/21 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
27
1 2 3 4 5 6 7 8 9 10
0V
26-10 29-1
24-8
0V
0V
0V
0V
0V
0V
1 1 3 1
S49 S50 S23 S17 K37 S23
28-9 09-3 28-4
20A DRM570024L
3 3 4 9
41
101
102
103
91
46
X20 X21 X22 X23 X24 X25 X26 X27 X30 X31
26-2 29-2
N1
Mitsubishi
FX3GA-60MR
Mitsubishi PLC
paper pallet down limited
auto feeder
air pump
warning
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
28
1 2 3 4 5 6 7 8 9 10
0V
28-10 27-2
07-6
10-2
22-6
22-9
0V
0V
0V
0V
0V
0V
1 1 3 3 3
S51 S52 S20 S22 S53 S34
20-9
20A 20A 20A
3 3 4 4 4
X40
54
55
93
94
82
83
95
66
X41
X32 X33 X34 X35 X36 X37 X40 X41 X42 X43
28-2 27-2
N1
Mitsubishi
FX3GA-60MR
Mitsubishi PLC
second paper pallet down manually
up limited
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
29
1 2 3 4 5 6 7 8 9 10
tube gluing
N1
Mitsubishi PLC
Mitsubishi
FX3GA-60MR
27-2 31-2
13 13 13 13 13 13
K5 K6 K7 K9 K10 K11
14 14 14 14 14 14
24V
27-10 31-1
0V 0V
27-10 31-1
K5 K6 K7 K9 K10 K11
1 9 1 9 12-6 1 9 12-6 1 9 1 9 12-8 1 9 12-9
2 10 2 10 2 10 2 10 2 10 2 10
3 11 3 11 3 11 3 11 3 11 3 11
4 12 4 12 4 12 4 12 4 12 4 12
7 11 7 11 7 11 7 11 7 11 7 11
8 12 8 12 8 12 8 12 8 12 8 12
REVISION
N1-PLC output 0
0 2017/4/21 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
30
1 2 3 4 5 6 7 8 9 10
air stripping
counting
N1
Mitsubishi PLC
Mitsubishi
FX3GA-60MR
30-2 32-2
Y14 Y15 Y16 Y17 COM6 Y20 Y21 Y22 Y23 COM7
13 13 13 13 13 13 13
K18 K12 K13 K14 K15 K16 K17
14 14 14 14 14 14 14
24V
30-10 32-1
0V
30-10 32-1
2 10 2 10 2 10 2 10 2 10 2 10 2 10
3 11 3 11 3 11 3 11 3 11 3 11 3 11
4 12 4 12 4 12 4 12 4 12 4 12 4 12
7 11 02-6 7 11 7 11 7 11 7 11 7 11 7 11
8 12 02-6 8 12 8 12 8 12 8 12 8 12 8 12
REVISION
N1-PLC output 0
0 2017/4/21 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
31
1 2 3 4 5 6 7 8 9 10
bottom stripping
bottom gluing
N1
Mitsubishi PLC
Mitsubishi
FX3GA-60MR
31-2
13 13 13
K19 K20 K21
14 14 14
24V
31-10 33-1
0V
31-10 33-1
K19 K20 K21
1 9 1 9 1 9
2 10 2 10 2 10
3 11 3 11 3 11
4 12 4 12 4 12
7 11 7 11 7 11
8 12 8 12 8 12
REVISION
N1-PLC output 0
0 2017/4/21 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
32
1 2 3 4 5 6 7 8 9 10
24V
32-10 34-1
0V
32-10 34-1
22-10
22-6
21-2
21-3
3 3
S35 S35
33-5 33-4
20A 20A
4 4
151
152
56
75
2000
2001
24V X50 X51 X52 X53 X54 X55 X56 X57
N2
Mitsubishi
FX2N-8EX
Mitsubishi PLC
bottom gluing off
door switch
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
33
1 2 3 4 5 6 7 8 9 10
24V
33-9 36-1
0V
33-9 35-1
3 3
S44 S6
35-2
20A 20A
4 4
300
89
24V X60 X61 X62 X63 X64 X65 X66 X67 X70
35-2
N3
Mitsubishi
FX2N-16EX
Mitsubishi PLC
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
34
1 2 3 4 5 6 7 8 9 10
0V
34-10 36-1
3 3 3 3
S6 S7 S7 S8
34-9 35-4 35-3
20A 20A 20A 20A
4 4 4 4
1002
301
400
401
34-1
N3
Mitsubishi
FX2N-16EX
Mitsubishi PLC
auto handle synchronous
REVISION
N3-PLC drawing 0
0 2017/4/22 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
35
1 2 3 4 5 6 7 8 9 10
24V
34-10 37-1
0V
35-10 37-1
0V
21-4
3
S58
20A
4
76
68
37-2
N4
Mitsubishi
FX2N-8ER
Mitsubishi PLC
REVISION
N4-PLC drawing 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
36
1 2 3 4 5 6 7 8 9 10
36-2
COM0 Y0 Y1 Y2 Y3
13
K22
14
0V
36-9
24V
36-9
K22
1 9
2 10
3 11
4 12
5 9 13-7
6 10
7 11
8 12
REVISION
N4-PLC drawing 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
37
1 2 3 4 5 6 7 8 9 10
L1
B2 PR12-4DN proximity switch China Autonics 21 gusset jam proximity switch (not in use)
B20 PR12-4DN proximity switch China Autonics 22 corner waste sucking / blowing
B22 PR12-4DN proximity switch China Autonics 22 feeder stop proximity switch
REVISION
Bill of materials 0
0 2017/5/21 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
38
1 2 3 4 5 6 7 8 9 10
L1
B23 BR4M-TDTD.1 beam photoelectric switch China Autonics 22 bottom gluing photo sensor 1
B24 BR4M-TDTD.2 beam photoelectric switch China Autonics 22 bottom gluing photo sensor 2
B26 PR12-4DN proximity switch China Autonics 22 bottom gluing on proximity switch
B27 PR12-4DN proximity switch China Autonics 22 bottom gluing off proximity switch
B28 PR12-4DN proximity switch China Autonics 49 handle making unit hot melt glue gluing
B32 PR12-4DN proximity switch China Autonics 50 E servo tension down limited
B33 PR12-4DN proximity switch China Autonics 50 E servo tension down limited
20 - 27 - 02
K2 DRM570024L relay Weidmüller machine run
- 12
REVISION
Bill of materials 0
0 2017/5/21 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
39
1 2 3 4 5 6 7 8 9 10
L1
K25 DRM570024L relay Weidmüller 51 - 57 handle making unit hot melt glue gluing
REVISION
Bill of materials 0
0 2017/5/21 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
40
1 2 3 4 5 6 7 8 9 10
L1
M10 51K18GU-CF Motor China Wuma 13 bottom cold glue rotating motor
M12 GLW18Y63(I:5) gear motor China Wuma 04 waste handle belt motor
M13 MESA 6 ,4 H/G hot melt glue machine Nordson 04 side hot melt gluer
M14 SGM7G-13AFC61 servo motor YASKAWA 47 handle maker main servo motor
M15 Problue 15 hot melt glue machine Nordson 46 hot melt gluer for handle maker
M16 6RK200GU-CFT Motor China Maili 12 top folding glue rotating motor
M23 PG-200D-50W230AL web guiding control system China Gangqun 46 web guiding controlle
M24 PG-200D-50W230AL web guiding control system China Gangqun 46 web guiding controlle
M25 SGM7J-08AFC6 servo motor YASKAWA 47 left side handle feeding servo motor
M26 SGM7J-08AFC6 servo motor YASKAWA 47 right side handle feeding servo motor
M27 SMM08-2R75-U1NL5 servo motor China Weichuang 47 left side handle cutting servo motor
M28 SMM08-2R75-U1NL5 servo motor China Weichuang 47 right side handle cutting servo motor
REVISION
Bill of materials 0
0 2017/5/21 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
41
1 2 3 4 5 6 7 8 9 10
L1
25 - 26 - 28
N1 FX3GA-60MR Mitsubishi PLC Mitsubishi - 29 - 27 -
30 - 31 - 32
54 - 55 - 56
N5 DVP32ES200T Taida PLC DELTA
- 57
REVISION
Bill of materials 0
0 2017/5/21 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
42
1 2 3 4 5 6 7 8 9 10
L1
REVISION
Bill of materials 0
0 2017/5/21 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
43
1 2 3 4 5 6 7 8 9 10
L1
S52 LXW5-11G1 micro switch Chengzheng 29 second paper pallet down limited
REVISION
Bill of materials 0
0 2017/9/19 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
44
1 2 3 4 5 6 7 8 9 10
L1
REVISION
Bill of materials 0
0 2017/11/20 lilinquan
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L1 Electrical Cabinet A
User data 1 User data 2
45
1 2 3 4 5 6 7 8 9 10
6mm^2
N N
1-02-9 47-1
4
T16 2
2
1-04-7 47-1
N
S16
1-04-7
2
32A
QF3
R16
1-04-7
N
SMPS
A2
PE 24V 0V
QF2 1 3 5
0.63-1A QF20
0.53A
QF19 1 3 5 10A
I I I
0V
2
24-32A
2 4 6
32A 1mm^2
I I I
2 4 6
L1 L2 L3
KM21
24V
0V
PE
N
N
2
2
LC1D09BDC
48-2
0V
T1 T2 T3
1mm^2 6mm^2
48-1
48-1
1-05-10
47-1
W15
U15
V15
PE
PE
R
T
S
U V W PE R S T PE L N L N L N PE L N PE
M21 M15 fan fan web guiding control system web guiding control system
Y2-631-2P-0.18-B3
0.53A M Problue 15
31A M M19
0.14A M M20
0.14A M M23
M
M24
M
0.18KW 5KW
REVISION
B electrical cabinet circuit 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
46
1 2 3 4 5 6 7 8 9 10
N
46-10 54-1
2
46-10 54-1
1mm^2
2.5mm^2 1mm^2 1mm^2 1mm^2
N
N
2
2
U1 U2 U3
SGD7S-120A00A SGD7S-5R5A00A SGD7S-5R5A00A
U4 U5
SD600A-T2-R75 SD600A-T2-R75
L1C
CN7
L1C
CN7
L1C
CN7 N L2
N L2
-1 -1 -1 P P
CN3 CN3
-2 -2 -2 D D
- - - C C
CN8 CN8 CN8 PE PE
U U U
CN2 CN2 CN2
V V V
W W W
PE PE PE
53-2
53-5
52-7
52-3
52-5
PE
46-9 54-1
U V W U V W U V W U V W U V W
M14
10.7A
M M25
4.4A
M M26
4.4A
M M27
3A
M M28
3A
M
1.3KW 0.75KW 0.75KW 0.75KW 0.75KW
REVISION
B electrical cabinet driver 0
0 2017/4/24 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
47
1 2 3 4 5 6 7 8 9 10
24V
46-9 49-1
5
K23
56-8
9
A1
KM21
A2
0V
0V
46-9 49-1
KM21
L1 T1 46-2
L2 T2 46-2
L3 T3 46-2
13 14
21 22
REVISION
B electrical cabinet controlling circuit 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
48
1 2 3 4 5 6 7 8 9 10
24V
48-9 50-1
24V
172
X4
X6
X12
X13
171
X12
X12
X13
171
X0
X2
B
55-3
55-2
53-2
55-2
53-5
51-2
54-8
51-2
54-7
54-8
0V
0V
0V
0V
0V
0V
0V
0V
0V
handle making hot melt gluing
AB servo paper checking
54-5
52-7
54-6
B servo feeding
0V
48-9 50-1
REVISION
B electrical cabinet controlling circuit 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
49
1 2 3 4 5 6 7 8 9 10
24V
49-10 51-1
24V
24V
24V 24V 24V 24V 24V 24V 24V
B11 B34 B35 B30 B31 B32 B33
2000 P/R encoder proximity switch proximity switch proximity switch proximity switch proximity switch proximity switch
5
OUT A 0V OUT B 0V OUT 0V OUT 0V OUT 0V OUT 0V OUT 0V OUT K26
57-5
DRM570024L
B相
X15
X15
X16
X16
X1
X1
A相
A相
B相
B相
55-3
55-4
55-4
55-4
0V
0V
0V
0V
0V
0V
0V
24V
Y11
53-5
53-2
53-5
54-6
54-6 0V
E servo on
E servo on
0V
49-10 51-1
REVISION
B electrical cabinet controlling circuit 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
50
1 2 3 4 5 6 7 8 9 10
24V
50-10 52-1
24V
5
K25
57-4
DRM570024L
9
+24V
24V
B38
proximity switch
0V OUT
+24V
+24V
+24V
+24V
13 13 5 5
K27 K28
K27 K28
51-2 51-2
14 14 9 9
D101
D102
171
172
0V
24V 24V
Y9 Y10
49-6
49-7
53-3
53-6
solenoid valve solenoid valve
0V 0V
0V
0V
0V
50-10 52-1
K27 K28
1 9 1 9
2 10 2 10
3 11 3 11
4 12 4 12
5 9 51-3 5 9 51-3
6 10 6 10
7 11 7 11
8 12 8 12
REVISION
B electrical cabinet controlling circuit 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
51
1 2 3 4 5 6 7 8 9 10
24V
51-10 53-1
0V
51-10 53-1
55-4
49-2
2K 2K 2K 2K 2K 2K
X17
B
7 8 15 14 7 8 15 14 7 11 8 12 25 26 40 47
Y16
Y17
Y0
Y2
56-5
57-5
56-6
57-6
point No.26=White point No.40=0V KA2 0V
47-4
47-6
47-3 REVISION
B electrical cabinet controlling circuit 0
0 2017/4/24 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
52
1 2 3 4 5 6 7 8 9 10
24V
52-10 54-1
0V
52-10 54-1
50-2
49-5
51-4
50-2
50-3
49-6
51-5
X12
X13
A相
A相
B相
B相
41 37 31 30 14 35 11 41 37 31 30 14 35 11
47-8
47-10
REVISION
B electrical cabinet controlling circuit 0
0 2017/4/24 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
53
1 2 3 4 5 6 7 8 9 10
PE
47-10
2
47-10
N
47-10
24V
53-10 56-1
0V
53-10 56-1
3 1 1 3 3
S5 S55 S56 S11 S12
X7
49-1
50-4
50-4
49-4
49-8
49-6
49-9
X10
X11
X3
171
X0
X2
X4
X6
X1
X1
X7
X1
L N PE NC +24V 24G S/S X0 X1 X2 X3 X4 X5 X6 X7 X10 X11
55-2
N5
DELTA
DVP32ES200T
Taida PLC
limit switch
B servo photosensor
slitter ON
A servo photosensor
rope detect senso
REVISION
N5-PLC input 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
54
CONTRACT:
1
54-1
N5
X12
DELTA
A servo paper feeding single 49-4
X12
2
DVP32ES200T
X13
B servo paper feeding single 49-5
X13
X14
AB servo paper checking photosensor 49-3
X14
3
X15
1-09-2
X15 X15
E servo tension up limited 50-5
X15
X15
50-6
X16 X16
LOCATION:
E servo tension down limited 50-7
X16
4
X16
50-8
L2
X17
E servo point NO.25 52-8
X17
Taida PLC
56-1
5
N5-PLC input
6
Electrical Cabinet B
7
0
REV.
User data 1
DATE
2017/4/23
8
NAME
Administrator
9
User data 2
CHANGES
10
55
SCHEME
REVISION
1 2 3 4 5 6 7 8 9 10
slitter ON
A servo
B servo
N5
Taida PLC
DELTA
DVP32ES200T
55-2 57-2
13
K23
Y0
Y2
14
52-3
52-5
1-06-7
24V
54-10 57-1
0V
54-10
K23
1 9
2 10
3 11
4 12
5 9 48-2
6 10
7 11
8 12
REVISION
N5-PLC output 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
56
handle making unit hot melt glue gluin
56-1
Y12
Y14
Y15
Y16
Y17
13 13 13
K39 K25 K26
52-3
52-5
14 14 14
24V
56-10
K25 K26
1 9 1 9
2 10 2 10
3 11 3 11
4 12 4 12
5 9 51-2 5 9 50-9
6 10 6 10
7 11 7 11
8 12 8 12
REVISION
N5-PLC output 0
0 2017/4/23 Administrator
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
L2 Electrical Cabinet B
User data 1 User data 2
57