K5 UT+Electric+Control+Manual
K5 UT+Electric+Control+Manual
Safety Instruction
· Please read this manual carefully, also with related manual for the machinery before
use the controller.
· For installing and operating the controller properly and safely, qualified engineers
are required.
· Please stay away from arc welding equipment, in order to avoid electromagnetic
interference and malfunction of the controller.
· Keep room temperature bellow 45°c and above 0°c
· Do not use in humidity below 30% or above 95% or dew and mist places.
· Please turn off the power and unplug the power cord, before install the control box
and other components,
· To prevent interference or electric leakage accidents, please make the ground work;
the power cord ground wire must be securely connected to earth by an effective
way.
· All parts for the repair provided by the Company or approved before use.
· Please turn off the power and unplug the power cord before any maintenance
action. There is dangerous high voltage control box, you must turn the power off
after one minute before opening the control box.
· The symbol in this manual means Safety Precautions, please pay attention to it
and strictly follow it, to avoid any unnecessary damage.
1 Installation Instructions
1.1 Product specifications
:If it is difficult toinserted plug into socket, please check whether them are matching with each other, or the inserting direction
1/8
Fig.1-2 Controller Interface Definition
1.3 Wiring and Grounding
We must prepare the system grounding project, a qualified electrical engineer is requested for the construction.
Product is energized and ready for use; you must ensure that the power outlet the AC input is securely grounded.
The grounding wire is yellow and green lines, it must be connected to the grid and reliable security protection on the
ground to ensure safe use, and prevent abnormal situation.
:All power lines, signal lines, ground lines, wiring not to be pressed into other objects or excessive distortion, to ensure safe
use!
2 Operation Panel Instructions
2.1 Operation Panel Display Instruction
According to the system working state, the LCD module of operation panel will display the current sewing
mode, parameters, start / end back tacking, and presser foot, needle position, trimming, soft start sewing etc.
Function mark of the operation panel is as follows:
2/8
Index mark Description Index Icon Description
Index Icon Description Index Icon Description
⑦ Trimming counter ○
17 88888888 Number/parameter display
⑧ Light level ○
18
⑩ Soft start ○
20
In the boot state, long press key to enter the parameter modes. After modify the
Parameter setting key
parameters, press key to storage. Then long press key to exit this mode.
Under the normal sewing mode, press key, switch between cycle sewing midway parking
Presser foot key
presser foot and sewing after the end of automatic trimming presser foot.
Light level button and Short press Key,light level will change.Long press Key,circular will cut line
Shear line switch switch.
At the time of an error, short press Key, will be submitted to the cause of the
Voice button
The parameter
Parameter value increment key.
increment setting key
The parameter
Parameter value decrement key.
decrement setting key
Parameters selection toward to left key. ( In constant-stitch sewing mode, long press this
The left selection key
key, One-shot-sewing can be turned on or turned off. )
factory reset Long press 3 s touch switch to restore the factory program.
3/8
2.3 Composite keys that
The serial Appearance of the Name Functional description
number combination
1 Trimming shortcuts Quickly into the trimming mode, press the button
+
or , can automatically switch to pin
P99 0~2 1 language selection 0: off, 1: Chinese, 2:English, default language 1 Chinese
P01 200~5000 4000 the maximum speed of free sewing (the global maximum speed)
P08 0~200 0 End encryption stitches number (0 is not encrypted function, if there is a pin number for
encryption seam features)
P09 0/1 0
Soft start switch (0:off; 1: on)
P10 0~4 0
Quantity of meter to adjust
P16 1~3000 50 Adjust the lift foot response time after the sensor has detected the cloth.
4/8
Automatic induction presser foot sensor setting (between the maximum and minimum
P17 0~99 0
value of the 02C parameter display)
P30 0~31 0 Feedforward torque of motor: 0: normal functions 1-31: feedforward torque level
P33 0~100 6 Encryption seam solenoid off time per cycle (ms)
P37 0~100 5 Encryption seam solenoid on time per cycle (ms), means the clamp strength.
P38 1~999 120 Flat seaming shear velocity (under the knife to maintain time) -- -- -- -- -- - under the knife
1~999 Scavenging action time delay -- -- -- -- -- -- -- -- -- -- on the knife (note: this is also flat
P39 160
seaming machine cut line)
1~999 Duration and linear velocity (scan line) -- -- -- -- -- -- -- -- on the knife (note: this is also flat
P40 30
seaming machine cut line)
P43 0~25 2 Sweep line, choice of blowing function (2 for scavenging; 8 for blowing)
P50 1~500 100 Presser foot lifting electromagnet full output time ms
P51 0~100 15 Presser foot lifting electromagnet per cycle opening time (ms)
P52 1~800 150 Running delay time when presser footer comes down (ms)
P60 200~5500 4000 The maximum speed of constant sewing (Automatic test speed)
Special mode:
0: normal Mode
1: simply sewing mode
2: motor initial angle measurement (Do not remove the belt)
P62 0~4 0
3: Automatically setting the pulley ratio by the CPU. (Synchronizer is necessary and the
belt not removed)
4: automatic test modle 1 (It has needle stop position of automatic test, running and
stopping 5S)
P66 0/2 2 Safety switch function set: 0:off 2:on
P71 0~50 0 Slow release lifter level adjustment, the smaller values and the faster quickly (OC open
5/8
time)
011 Counter for sewing pieces 026 The ratio between motor and machine
012 The head of real speed 027 The total used time(hours) of motor
The stitch counter reaches the limit. Press key to cancel the alarm and
Stitch counter alarm
reset the counter.
The trimming counter reaches the limit. Press key to cancel the alarm and
Trimming counter alarm
reset the counter.
6/8
Power is off alarm Please wait for 30 seconds, then turn on the power switch
Please check the trimming cutter is back the original place, after checking
Safety switch alarm still safety alarm, please adjust the sensor holder, if still cannot solved,
Shut down the system power supply, 30 seconds to connect the power
SLEEP Dormancy supply, controller, if still doesn't work, please replace the controller and notify
the manufacturer.
1.Make sure the machine has been connected correctly; 2. Confirm that the control box match with the
7/8
Initial motor electrical angle - Try 2 to 3 more times after power down
Err-12
failure - if it still does not work, please replace the controller and inform the manufacturer.
Turn off the system power, check if the motor sensor plug is loose or dropped off,
Err-13 Motor HALL failure restore it and restart the system. If it still does not work, please replace the controller
and inform the manufacturer.
DSP Read/Write EEPROM
Err-14
failure
Err-15 Motor over-speed protection
Turn off the system power, restart the system after 30 seconds, if it still does not work,
Err-16 Motor reversion
please replace the controller and inform the manufacturer.
HMI Read/Write
Err-17
EEPROM failure
Err-18 Motor overload
8/8