Ad Converter Sad-30dc Manual

This document provides information about a gyro interface unit, including: 1) It has an FND display showing bearing from 000.0 to 359.9 degrees and operates from 10-30V DC using 0.1A maximum. 2) It can interface with gyro compasses that use AC synchro or DC step signals at various rotation rates. 3) DIP switches are used to configure the gyro type, rotation rate, voltage levels, and other settings. Proper setup is required for the interface unit to function correctly.

Uploaded by

최다형
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
613 views4 pages

Ad Converter Sad-30dc Manual

This document provides information about a gyro interface unit, including: 1) It has an FND display showing bearing from 000.0 to 359.9 degrees and operates from 10-30V DC using 0.1A maximum. 2) It can interface with gyro compasses that use AC synchro or DC step signals at various rotation rates. 3) DIP switches are used to configure the gyro type, rotation rate, voltage levels, and other settings. Proper setup is required for the interface unit to function correctly.

Uploaded by

최다형
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SAD - 30DC GYRO

GYRO INTERFACE UNIT

GYRO INTERFACE UNIT

SAD - 30DC

OPERATION & TECHNICAL MANUAL ★ Display method : FND

★ Bearing Display : 000.0 to 359.9 degree

★ Power supply
- Input power : DC 10 ~ 30 V
- Current : 0. 1A MAX @ 24 VDC
- Efficiency : 77 % min

★ Environmental condition : 0 ℃ ~ +55 ℃

★ Following speed : 30 °/sec

★ Data out : NMEA0183 & 422 $HEHDT,000.0,T*F

★ Gyro Compass : 1) AC SYNCHRO : 360X, 180X, 90X, 36X


2) DC STEP : 360X, 180X, 90X, 36X

SAMYUNG ENC CO., LTD.


Set up for Main PCB (DIP S/W 1, 2, 3) ◆ DIP SW3 Standard ( DIP SW2 (8P) is Gyro type and Gyro rate Setting. )
Factory set (Default) is Synchro 360°

◆ DIP SW3 1 to 5 Gyro type and Gyro rate


Please select accordance with Gyro type (Step or Synchro : 1 to 2) and Gyro rate (3 to 5)
AC SYNCHRO TYPE
1 2 3 4 5 Gyro rate
OFF OFF ON OFF OFF 36 X
OFF OFF OFF ON OFF 90 X
OFF OFF ON ON OFF 180 X
OFF OFF OFF OFF ON 360 X
DC STEP TYPE
1 2 3 4 5 Gyro rate
OFF ON ON OFF OFF 36 X
OFF ON OFF ON OFF 90 X
OFF ON ON ON OFF 180 X
OFF ON OFF OFF ON 360 X

◆ DIP SW3 6 (Revolving Direction)


ON: REVERSE (CW)
OFF: NORMAL (CCW)

◆ DIP SW1 Standard ( DIP SW1 (10P) is AC Synchro Voltage Setting. )


◆ DIP SW3 7 (Data out Interval)
Factory set (Default) is 2, 4, 6, 8, 10 ON
ON: 1 sec
OFF: 2 times At 1sec

◆ DIP SW3 8 (Frequency Select)


ON: 400Hz & 500Hz
AC Synchro 20V ~ 40V - > 1, 3, 5, 7, 9 ON OFF: 50Hz & 60Hz
AC Synchro 40V ~ 90V - > 2, 4, 6, 8, 10 ON
※ CAUTION
◆ DIP SW2 Standard ( DIP SW2 (9P) is DC Step Voltage Setting. ) 1. Turn and off the Power switch
Factory set (Default) is 2, 5, 8 ON 2. When you change any DIP SW1 (DIP switch), Please Turn and on
3. Otherwise, it dose not work properly.
(DIP SWICH를 설정시 전원을 OFF한 후 설정 하세요.)

※ SPEAR PART
DC Step 20V ~ 40V - > 3, 6, 9 ON 1.. FUSE : 1A (1EA)
DC Step 40V ~ 70V - > 2, 5, 8 ON 2. BOLT : 4*6mm (4EA)
TERMINAL BLOCK SWITCH CONTROL

Not use 20

1) Synchro Type GYRO

◆ DIMMER : Adjustment For brightness Of FND


CW : MAX
CCW : MIN

2) Step Type GYRO ◆ ▲ (Up) & ▼ (Down) Button Control


When you push ▲ (Up) or ▼ (Down) Button, the degrees will increase or decrease
heading values of gyro compass step as follows.
- Push a time (Slow adjust) : 0.1 ° step.
- Keep push (Fast adjust) : 0.1 °, 1 °, 10 ° step.

3) DC IN : DC 10 ~ 30 V

※ In case of gyro type CMZ-300X or CMZ-500, you should be connected line for
GYRO Interface Unit from DC-STEP PORT of MAIN GYRO (Do not connect from
Gyro repeater). If you connect line from Gyro repeater, it will not be work.
(CMZ-300X 또는 CMZ-500 REPEATER는 DC SYNCHRO 이므로 INTERFACE가 작동하지
않으므로 CONTROLLER 내의 DC-STEP PORT로 결선하여주세요.)