SD119 Series Smoke & Heat Alarms

The SD119 series are photoelectric smoke and heat alarms that meet UL 268 and EN 54-7/5 standards. They are available in 2-wire and 4-wire models to provide fast and reliable smoke and heat (135°F) detection on either independent or combined detection circuits. The alarms have features like advanced detection algorithms, easy installation, and durable sensor heads. They are suitable for use in fire alarm signaling systems.

Uploaded by

Percy Manchego
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
185 views3 pages

SD119 Series Smoke & Heat Alarms

The SD119 series are photoelectric smoke and heat alarms that meet UL 268 and EN 54-7/5 standards. They are available in 2-wire and 4-wire models to provide fast and reliable smoke and heat (135°F) detection on either independent or combined detection circuits. The alarms have features like advanced detection algorithms, easy installation, and durable sensor heads. They are suitable for use in fire alarm signaling systems.

Uploaded by

Percy Manchego
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

SD119 series

Conventional Photoelectric Smoke and Heat Alarm


All of the Sentek’s SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for
use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised
zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with
corresponding NFPA 72E standards, local codes, and ordinances.
The SD119 series include 2-wire and 4-wire detectors, which provide fast and reliable
response for photoelectric smoke and heat (135oF) detection. While the smoke and heat detection
P
P

circuits operate independently, their outputs being "OR' connected, The Sentek’s SD119 series
detectors provide the fire detection performance by acting as a smoke sensor and/or a 135oF heatP
P

detector at the same location.

Product Features:
 2 or 4 wire models
 Advanced detection and discrimination algorithms
 Easy installation and maintenance
 Sleek low-profile housing design
 Durable sensor head, no need for replacement
 SMD circuit board design-satisfactory quality and reliability guaranteed
 Integrated heat detector for SD119-2H and SD119-4H models
 N/C (normal/close)-N/O (normal/open)selectable relay output
 AR (Auto Reset) function for security systems (optional for 4 wire models) Sensor base option:
standard and Shottky Diode
 Five-year limited warranty

The range includes:


SD119- 2 2 wire photoelectric smoke alarm
SD119- 2- LED 2 wire photoelectric smoke alarm with remote LED output
SD119- 2H 2 wire photoelectric smoke and heat alarm
SD119- 2H- LED 2 wire photoelectric smoke and heat alarm with remote LED output
SD119- 4 4 wire photoelectric smoke alarm (12/24/48VDC)
SD119- 4B 4 wire photoelectric smoke alarm with Buzzer (12/24/48VDC)
SD119- 4AR 4 wire photoelectric smoke alarm with auto-reset function (12/24/48VDC)
SD119- 4ARB 4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24/48VDC)
SD119- 4H 4 wire photoelectric smoke and heat alarm (12/24/48VDC)
SD119- 4HB 4 wire photoelectric smoke and heat alarm with Buzzer (12/24/48VDC)
SD119- 4HAR 4 wire photoelectric smoke and heat alarm with auto-reset function (12/24/48VDC)

1
SD119 series

Product Specification:

Standby Alarm Surge Star-Up Permissible


2/4 Voltage
Model Thermal Current Current Current Time Current Frequency Alarm contact Base model
wire DC
(Max.) 12/24V (Max.) (Max.) (Max.)

SD119-2 2 10.8〜33V 80μA 22/55mA 160μA 30S 80mA 1〜3 Seconds — P/N852001

SD119-2L 2 10.8〜33V 80μA 22/55mA 160μA 30S 80mA 1〜3 Seconds — P/N854001

SD119-2H 2 57°C 10.8〜33V 80μA 22/55mA 160μA 30S 80mA 1〜3 Seconds — P/N852001

SD119-2HL 2 57°C 10.8〜33V 80μA 22/55mA 160μA 30S 80mA 1〜3 Seconds — P/N854001

SD119-4-12V 4 10~13.8V 80μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4-24V 4 20~27.6V 80μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

S119-4H-12V 4 57°C 10~13.8V 80μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

S119-4H-24V 4 57°C 20~27.6V 80μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4AR-12V 4 10~13.8V 100μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

SD119-4AR-24V 4 20~27.6V 100μA 45mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

SD119-4HAR-12V 4 57°C 10~13.8V 100μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

SD119-4HAR-24V 4 57°C 20~27.6V 100μA 45mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4B-12V 4 10~13.8V 80μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4B-24V 4 20~27.6V 80μA 45mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4HB-12V 4 57°C 10~13.8V 80μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4HB-24V 4 57°C 20~27.6V 80μA 45mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4HARB-12V 4 57°C 10~13.8V 80μA 30mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

SD119-4HARB-24V 4 57°C 20~27.6V 80μA 45mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

SD119-4-48V 4 10.8~60V 80μA 25mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4AR-48V 4 10.8~60V 80μA 25mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

SD119-4H-48V 4 57°C 10.8~60V 80μA 25mA 160μA 30S 80mA 1〜3 Seconds Form A P/N854001

SD119-4HAR-48V 4 57°C 10.8~60V 80μA 25mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

SD119-4HARB48V 4 57°C 10.8~60V 80μA 25mA 160μA 30S 80mA 1〜3 Seconds Form A /Auto Reset P/N854001

2
SD119 series

Product Character:

Smoke Sensitivity: 0.08~0.2db/m(EN standard) or 0.98~4.0%/FT Obscuration (UL standard)

Ceiling Spacing: 50 foot rating for heat sensor

Reset Voltage: less than 1 volt

Reset Time: less than 1 second

Alarm Indicator: LED continuously emitting red light

Remote Output: 25 mA max., diode gate

Temperature Range: -10°C to 55°C, UL268 temperature: 0~37.8°C

Permissible Current: 80mA maximum

Humidity: 0 to 95% RH, no condensation or icing

Alarm Contact: (for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC

Dimensions: 100mm (dia) x 46mm (ht) with base

Weight: 130g/set with base