RPM65 digital multifunction power analyser
panel mounting power analyser according IEC 61000-4-30 class S
The network analyzer RPM65 for accurate monitoring of main
electrical parameters in three phase or single phase networks. The
instrument measures continuous voltage and current according to
the norm EN61000-4-30 class S. Thanks to precise measurement
and a high sampling rate. It is also ideal for particular measuring
points in electrical energy monitoring systems. The communication
interface RS485 with Modbus RTU protocol predefine RPM65 can be
used as measure point in SCADA system
► True RMS measurements (512 samples/cycle)
► For single-phase, two-phase, three-phase system
► Measurements:VL-L, VL-N, I, In, Cos∅, Pf, Hz, W, ∑W, Va, ∑Va, Var,
∑Var, import Kwh, export Kwh import Kvarh, export Kvarh, V-THD, I-THD,
1-63th harmonic , system running hours, % voltage unbalance,
% current unbalance, % system load, total frequency, temperature & humidity(option) RS-485 Web
Serial Server
► 3 voltage and 4 current input (Measure or calculate the neutral current)
ETHERNET
► Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
► % system load and system running hours
► Maximum, minimum and demand for U, I, P, Q, S in hours, days, months
► Real time clock with integrated backup rechargeable battery
► Four quadrants energy measurement and Monthly energy calculation
► 2 pulse output and RS485 communication: Modbus RTU
► Waveforms and phase diagram for voltage, current
► Alarm event log
► Micro SD(support 32GB) for data logger
► Data recorded in standard excel file formats for further EN50160 analysis
► English, Chinese (traditional & simplied)
► Moduel function options (only one can be selected)
● 7 digital input +2 relay output(remote or alarm)(Standard)
● 7 digital input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,I1,I2,I3 (option)
● Ethernet (Modbus TCP), Web server+2 digital input +2 relay output(remote or alarm) (option)
● Temperature & humidity Measurement +2 digital input +2 relay output(remote or alarm) (option)
Optional System
_ load 26.7 % Phase diagram
Instantaneous measure
● Four quadrants energy measurement ULn
_ 220. 5 ∑P 224. 7 Instantaneous harmonic
V 1-V 2 120
V 2-V 3 120
o
o
380. 8 ∑Q 39. 6
o
and electric CO2 emissions accumulate ULL Max / min / demand V 3-V 1 120
V 1-I1 15 o
● Monthly energy and electric CO2 emissions Waveform & diagram V 2-I2 15 o
calculation and recording
∑I 400. 6 ∑S 264. 4
_ Energy V 3-I3 15
Cos1 0.966
o
● Leakage current indication Fr. 50. 1 Hz Pf 0. 85 Event Log Cos2 0.966
Cos3 0.966
System setup
● Other language
I: O: 22:30
Wareform: V1 Voltage harmonics: L1 Event log
100
90 09 : 31 : 21 25 / 12 / 2018 DD/MM/YY
Order 80
70
60 Event-type: Un Alarm: 01
50
RPM65-x Standard 40
x=A Analog output 30 Hight value: 245
20
10
x=E Ethernet 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
Low value: 239
x=T Temperature & humidity I: O: 22:30 I: O: 1 22:30
11 Version: 2021.03
RPM65 digital multifunction power analyser
panel mounting power analyser according IEC 61000-4-30 class S
Data logger and software
Power monitoring software (PCMS) is designed for
remote control and management of all Romaz
instruments equipped with communication interface.
Standard excel file formats gives the possibility to have
a quick view and analysis on all stored data without any
special software. PCMS is provided to perform
statistical analysis and generate reports on recorded
data according to EN50160 PQ standard.
romaz
Ethernet RS485/Ethernet
HMI
Technical data
Characteristics Characteristics RPM65
RPM65
Auxiliary supply Ambient condition
Operating voltage (Un) 85···265 VAC/DC Opterating temperature -10···+55°C
Storage temperature -25···+75°C
Power consumption 4VA
Relative humidity 95% max without condensing
Frequency 45···65Hz
Altitude max 2000m AMSL
Voltage measurement input Installation & use Internal
Measurement range 10···690VAC L-L Housing
Measuring mode True RMS
Flush mount 96*96mm
Measuring input impedance 4MΩ Size
The panel cut-size 92*92mm
Method of connection single-phase,two-phase,three-phase
IP40(optional IP54) on front
Degree of protection
Current measurement input IP20 housing and terminals
Reference current 1A or 5A Weight 400g
Measuring range 0,05···5.5A Standard
Measuring mode True RMS IEC 61010-1; IEC61557-1;
Overload capacity 10A (Through the external current transformer) IEC61557-12; IEC61326-1;
IEC62053-21; IEC62053-22;
Self-consumption 0,2VA IEC62053-31; IEC60068-2-1;
Reference standard IEC60068-2-30; IEC60364-5-52;
Accuracy IEC61000-3-2; IEC61000-3-3;
Voltage ± 0, 2 % IEC61000-4-2; IEC61000-4-3;
IEC61000-4-4; IEC61000-4-5;
Current ± 0,2% IEC61000-4-6; IEC61000-4-8;
Power ± 0,5% IEC61000-4-11; IEC61000-4-30
Measures
Power factor ± 0,5%
►Measuring: VL-L, VL-N, I, In, Cos, Pf, Hz, W, ΣW, Va, ΣVa,Var, ΣVar,
Harmonics ± 1% Kwh, Kvarh, THD-U, THD-I, 1-63th harmonics
►Real time clock
Frequency ± 0,02%
►System running hours
Active Energy ± Class 0.5S ►Four quadrants energy measurement and monthly energy calculation
►2 or 7 digital input and 2 relay output(remote or alarm) or analog output
Reactive Energy ± Class 0.5S ►Waveforms and phase diagram for voltage, current
►Alarm event Log(over and under): VL-L, VL-N, I, In, ΣW, ΣVar,
Insulation THD-U, THD-I
► RS485 communication: Modbus RTU
Insulation voltage 3kV for 1min,50Hz ► Ethernet communication: Modbus TCP, Web server (depend on order)
► Micro SD for data log (support 32GB)
Display
Display type 240x160 pix LCD Period 8GB 16GB 32GB
15 Minutes ≥15 Years ≥30 Years ≥60 Years
12