0% found this document useful (0 votes)
93 views15 pages

Cladding Catalogue + Data Sheet

This document is a certificate of compliance certifying that Tqneyat Al Alwah (Panels Technology Factory) - Technopanel has met the requirements for the Intertek ETL US Mark for Building Panels, Building Materials With Surface Burning Characteristics. Specifically, it has certified their FR B1 Aluminum Composite Panel product with a product specification ID of 41787 after testing and assessment. The certificate is valid until December 31, 2021.

Uploaded by

alaa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views15 pages

Cladding Catalogue + Data Sheet

This document is a certificate of compliance certifying that Tqneyat Al Alwah (Panels Technology Factory) - Technopanel has met the requirements for the Intertek ETL US Mark for Building Panels, Building Materials With Surface Burning Characteristics. Specifically, it has certified their FR B1 Aluminum Composite Panel product with a product specification ID of 41787 after testing and assessment. The certificate is valid until December 31, 2021.

Uploaded by

alaa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Certificate of Compliance

You have been awarded:


Intertek ETL US Mark for Building Panels,
Building Materials With Surface Burning
Characteristics
Standards: ASTM E84 (2016)

Certificate number: WHI17-30486701


This is a certificate of compliance to certify that the
bearer has successfully completed the
requirements of the above scheme which include
the testing of products, the initial assessment, and Organization: Tqneyat Al Alwah (Panels Technology Factory) -
are subject to continuing annual assessments of Technopanel
their compliance and testing of samples of products
taken from production (as applicable to the scheme) P.O. Box 10342, Bldg 214 – 217
and has been registered within the scheme for the Al Madaen Industrial Zone, New Kharj Road
products detailed. Riyadh 11433
Kingdom of Saudi Arabia

Product: Tqneyat Al Alwah (Panels Technology Factory) -


Technopanel - FR B1 Aluminum Composite Panel
Spec ID: 41787
Listing Information: See following page(s)

Certification body: Intertek Testing Services NA, Inc.


Initial registration: July 04, 2017
Date of expiry: December 31, 2021
Issue status: 9

www.intertek.com

The certificate and schedule are held in force by regular annual surveillance visits by Intertek Testing Services NA, Inc. and the reader or user should contact Intertek to validate its status. This certificate
remains the property of Intertek Testing Services NA, Inc. and must be returned to them on demand. This Certificate is for the exclusive use of Intertek's Client and is provided pursuant to the Certification
agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this certificate. Only the Client is authorized to permit copying or distribution of this certificate and then only in its
entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement. Any further use of the Intertek name for the sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the
agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.

Tqneyat Al Alwah (Panels Technology Factory) - Technopanel | 41787 | Rev: Feb 23 2021 12:39PM | Uncontrolled Copy Page 1 of 2
LISTING INFORMATION
Technopanel Fire-Retardant B1 Aluminum composite panel (FR-ACP) is a product consisting of two sheets of
aluminum bonded to each side of a halogen-free fire-retardant polyethylene core. Panels are available in 4mm,
5mm, or 6mm thickness.

FLAME SPREAD RATINGS


Panel tested*
Test Flame Spread Smoke Development
Standard Index Index
ASTM E84 5 20

Core tested**
Test Flame Spread Smoke Development
Standard Index Index
ASTM E84 30 145

*Results based on 6.0mm thick panel. Flame spread rating only valid with exterior skin facing towards the flame.
**Results based on testing with one side of aluminum skin removed and core material facing towards the flame.

Tqneyat Al Alwah (Panels Technology Factory) - Technopanel | 41787 | Rev: Feb 23 2021 12:39PM | Uncontrolled Copy Page 2 of 2
CERT IFIC AT E OF COM PLIANCE
Certificate Number R40168
Report Reference R40168-2020-10-23
Date 2020-November-02

Issued to: TECHNOPANEL


MADAIN INDUSTRIAL 212 TO 217, NEW KHARJ ROAD,
P.O BOX 10342, RIYADH 11433
Riyadh, KSA SA

This is to certify that SHEATHING MATERIALS


representative samples of
“Technopanel – FR A2 Aluminium Composite Panel” 6mm
thick. 6mm thick product to give coverage for 4mm and
5mm thickness.

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL723, Standard for Surface Burning Characteristics for
Building Materials

Additional Information: See the UL Online Certifications Directory at


https://iq.ulprospector.com for additional information

This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.

Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
 
  TECHNOPANEL FRPE‐ACP SPECIFICATION 

I. Product Description 

TECHNOPANEL  Fire‐Retardant  Aluminum  Composite  Panel  (FR‐ACP)  is  a  high  performance 


product  consisting  of  two  sheets  of  aluminum  bonded  to  each  side  of  a  halogen‐free  fire‐
retardant PE core. It is suitable to use for exterior and interior wall cladding applications or for 
buildings  under  renovation  that  are  designed  to  reduce  the  risk  of  structural  fire.  It  has  the 
capability  of  reducing  flame  spread  for  a  specified  intensity  and/or  duration,  low  smoke  and 
delays heat penetration across on it. 

II. Product Composition 

TECHNOPANEL FR‐ACP is basically composed of the following materials: 

 
PVDF Coating

  Aluminum 0.5 mm

Fire Retardant Polyethylene (FRPE) Core


 

  Aluminum 0.5 mm
Polyester Coating
 
 

1.  POLYVINYLIDENE  DIFLUORIDE  (PVDF)  COATING  –  paint    for  the  front  aluminum  sheet  with 
high  non‐reactive  and  pure  flouropolymer  coating  used  in  applications  requiring  the  highest 
purity, strength, resistance to solvents, acids, bases and heat, and low smoke generation during 
a fire event. PVDF is not susceptible to attack by UV light, so the resin does not break down on 
exposure  to  sunlight  which  gives  a  very  high  resistance  to  fading,  chalking  and  long‐term 
retention of gloss and color. 
 
Note: For other test values on coating properties, do refer to page 4. 
 
2. ALUMINUM SHEETS ‐ two sheets of aluminum that is bonded to each side of a fire retardant 
polyethylene core. They have excellent tensile strength, yield strength and elongation rate and 
with high resistance to corrosion. 
 
 
Type of Alloy  3003 
 
  Thickness  0.50 mm 
  
 
 
 
 


 
 
  TECHNOPANEL FRPE‐ACP SPECIFICATION 

 
 
3. HALOGEN‐FREE FIRE‐RETARDANT CORE – the main core of TECHNOPANEL FR‐ACP that it has 
the capability of reducing flame spread for a specified intensity and/or duration, low smoke and 
delays heat penetration across it. It acts as a thermal insulation barrier where the role is to turn 
polymer into a char, which separates the flame from the material. 

There  are  two  important  components  that  can  be  used  as  a  fire  retardant  core  for  polymer 
applications.  These  components  decompose  at  high  temperatures  absorbing  considerable 
amounts of heat in the process. In addition to behaving as a fire retardant, it is very effective as 
a smoke suppressant when applied to polymers such as polyethylene. 

The two components are: 

Mg (OH)2  Magnesium Hydroxide or  AL (OH)3  Aluminum Hydroxide 

In  addition  to  the  performance  of  the  FRPE  core,  it  is  Halogen‐free  that  limits  the  use  of 
hazardous substances on the product. The drive for creating these products is associated with 
the green movement as well as health concerns. When fire breaks out and harmful substances 
contained in plastics are ignited, toxic fumes are released into the surrounding area. Therefore, 
compliance with these directives is important in the preservation of life and the environment. 

4.  POLYESTER  COATING  –  a  seven  micrometer  (7µm)  polyester‐based  coating  for  the  back 
aluminum sheet that serves as an aid in protecting TECHNOPANEL FR‐ACP from risks of exposure 
to corrosion on the back surface of the panel after installation. 
 
 
 
5. PROTECTIVE FILM ‐ The decorative surface is being covered by an 80 micrometer thick self‐
adhesive protective film to protect it from scratch and any possible damages during processing, 
storage  and  installation.  It  is  composed  of  two  layers,  the  White  surface  with  TECHNOPANEL 
logo  on  the  outer  side  to  deflect  ultraviolet  rays  and  the  Black  surface  from  the  inner  side  to 
prevent ultraviolet rays from penetrating the inner surface. 
 
 
 
 
 
 
 
 
 
 
 
 


 
 
  TECHNOPANEL FRPE‐ACP SPECIFICATION 

 
 
III. Product Dimension  
 
1. Thickness  :  4 mm, 5mm and 6 mm 
2. Width  :  1240 mm 
3. Length  :  5800 mm 
      Provision: or under customer’s requirement between 2000 to 6000 mm. 
 
Note: Technopanel’s standard stock is 5800 x 1240 mm (L x W). 
 
4. Tolerances 
 
  Size  Permissible  Tolerance 
  Length ,mm  ±3 
  Width, mm  ±2 
 
Thickness,mm  ±0.2 
 
  Deviation of diagonal, mm  ≤5 
  Out of straight at sides, mm/m ≤5
  Warp, mm/m  ≤5 
   
 
IV. Surface Visual Quality 
 
The  appearance  of  decorative  surface  shall  not  have  any  damages,  irregularities  and 
abnormalities.  It  shall  be  inspected  in  accordance  with  the  appearance  criteria  for  Aluminum 
Composite Panel (Outside and Inside Cladding) with maximum allowable blemishes and defects 
on the criteria. 
 
 
V. Product Properties 
 
1. Panel Weight  Density 
 
 
 
ACP Thickness (mm) Panel Weight (kg/sq.m)
 
4 6.90 ± 0.5
5  8.30 ± 0.5
6  9.70 ± 0.5
 
 
 
 
 
 
 
 
 


 
 
  TECHNOPANEL FRPE‐ACP SPECIFICATION 
 

2. Coating Performance 
 
  National / International  Technopanel Actual and 
Test Item 
  Standard  Test Value 
  Coating Thickness,  
≥25 µm  31 µm 
  ISO 2360/2003 
  If gloss ≥ 70, max permissible 
  deviation ≤ 5 
Gloss Deviation,  
  60 ‐ 64 
ISO 2813/1978  If gloss<70, max permissible 
 
  deviation ≤10 
  Color Deviation,  
< 2.0 dE  0.6 dE 
  ASTM D2244‐07 
  Pencil Hardness,  
≥HB  3H 
  ISO 15184/1998 
  Coating Flexibility,  
≤2T   0T 
  ASTM D4145‐83 
  Adhesion Grade,   in grid way: Grade 0  in grid way: Grade 0 
  ISO 2409/2007  in circle way: Grade 1  in circle way: Grade 1 
  Impact Resistance,   No peel‐off,  
  ISO 6272‐2/2002  No peel‐off, no crack 
no crack at 50 kg.cm 
  Abrasion Resistance,  
  ASTM D968‐05  ≥ 5 L/um  ≥ 5.5 L/um 
 
  Hot Water Resistance,  No color change, crack & peel‐
No color change, no crack &
  ISO 2409/2007  off at 98~100C  
no peel‐off 
  in 120 min 
  Stain Resistance, 
  ASTM D1308 
  Acid Resistance,  
  ASTM D1308‐02 
  Alkali Resistance,  
  ASTM D1308‐02  No Change   No Change 
  Oil Resistance,  
  ASTM D1308‐02 
  Solvent (Cleaner) 
  Resistance,  
  ASTM D1308‐02 
  Brush Resistance, 
  ASTM D1308‐02  ≥10000 times of no change  No change 
  Salt Fog Resistance,  
  ASTM B117‐07  No change  No change 
  Aging and Weather     
  Resistance     
         Color Deviation  ≤ 3.0  0.6 
         Gloss Retention Grad.  ≥ Grade 2  Grade 2 
         Other Aging Performance  Grade 0  Grade 0 
 

 
 
  TECHNOPANEL FRPE‐ACP SPECIFICATION 

 
3. Mechanical Properties  
 
National / International  Technopanel Actual and 
Test Item 
Standard  Test Value 
Bending  (Flexural) 
Strength ,  >100 MPa  102 MPa  
ASTM D790‐10 
Bend Elastic (Flexural) 
Module,  >2.0 x 104 MPa   2.14 x 104 MPa  
ASTM D790‐10 
Shear Strength,  
> 28.0 MPa  28.6 MPa  
ASTM D732‐10 
Tensile Strength,  
40 MPa   42.3 MPa 
ASTM D638‐10 
Elongation Rate, 
<18 %  4.1%  
ASTM B557‐10 
180 Degree Peeling 
Strength,  7 N/mm  9.8 N/mm 
ISO 8510‐2/2006 
 
 
4. Thermal / Sound Properties  
 
National / International  Technopanel Actual and 
Test Item 
Standard  Test Value 
Coefficient of Thermal 
Expansion,   <4.0 x 10 ‐5 0C‐1  2.163 x 10‐5 0C‐1 
ASTM D696‐08 
Heat Deflection 
Temperature,         >105 0C  118.1 0C 
ASTM D648‐07 
Sound Transmission, 
<32dB  28dB 
ASTM E413‐04 
 
 
 
 
 
 
 
 
 
 
 
 


 
 
  TECHNOPANEL FRPE‐ACP SPECIFICATION 

 
 
5. Fire Performance Properties  
 
National / International  Technopanel Actual and 
Test Item 
Standard  Test Value 
BS 476 Part 6: Fire Test on 
Building Materials and 
Class O  Class O 
Structures  
(Fire Propagation) 
BS 476 Part 7: Fire Test on 
Building Materials and 
Class 1  Class 1 
Structures  
(Surface Spread of Flame) 
EN 13823 
Reaction to Fire Tests for 
Building Products. 
Building Products Excluding  For Compliance  Compliant 
Floorings Exposed to the 
Thermal Attack by a Single 
Burning Item 
EN ISO 11925‐2 
Reaction to fire tests ‐ 
Ignitability of Building 
Products Subjected to 
For Compliance  Compliant 
Direct Impingement of 
Flame 
Part 2: Single‐flame Source 
Test 
ASTM E84‐04  ‐ Smoke Develop Index 
Passed 
Surface Burning  (less than 450) 
 
Characteristics of Building  ‐ Flame Spread Index 
Passed 
Materials  (less than 25) 
 
 
 
The data in the technical document are general information and Technopanel has the right to change due to product 
changes, improvements and other factors pertaining to product performances and standard requirement. 
 
 
Please contact us for further information: 
 
TQNEYAT AL‐ALWAH FACTORY (TECHNOPANEL) 
Technical Engineering Department 
Riyadh‐New Kharj Road 
Madaen Industrial Zone Building 212 – 217 
P.O. Box 10342, Riyadh 11433 
Tel: +966‐11‐2447755 
Fax: +966‐11‐2429040 

  6 
 