Certificate of Compliance
You have been awarded:
Intertek ETL US Mark for Building Panels,
Building Materials With Surface Burning
Characteristics
Standards: ASTM E84 (2016)
Certificate number: WHI17-30486701
This is a certificate of compliance to certify that the
bearer has successfully completed the
requirements of the above scheme which include
the testing of products, the initial assessment, and Organization: Tqneyat Al Alwah (Panels Technology Factory) -
are subject to continuing annual assessments of Technopanel
their compliance and testing of samples of products
taken from production (as applicable to the scheme) P.O. Box 10342, Bldg 214 – 217
and has been registered within the scheme for the Al Madaen Industrial Zone, New Kharj Road
products detailed. Riyadh 11433
Kingdom of Saudi Arabia
Product: Tqneyat Al Alwah (Panels Technology Factory) -
Technopanel - FR B1 Aluminum Composite Panel
Spec ID: 41787
Listing Information: See following page(s)
Certification body: Intertek Testing Services NA, Inc.
Initial registration: July 04, 2017
Date of expiry: December 31, 2021
Issue status: 9
www.intertek.com
The certificate and schedule are held in force by regular annual surveillance visits by Intertek Testing Services NA, Inc. and the reader or user should contact Intertek to validate its status. This certificate
remains the property of Intertek Testing Services NA, Inc. and must be returned to them on demand. This Certificate is for the exclusive use of Intertek's Client and is provided pursuant to the Certification
agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this certificate. Only the Client is authorized to permit copying or distribution of this certificate and then only in its
entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement. Any further use of the Intertek name for the sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the
agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.
Tqneyat Al Alwah (Panels Technology Factory) - Technopanel | 41787 | Rev: Feb 23 2021 12:39PM | Uncontrolled Copy Page 1 of 2
LISTING INFORMATION
Technopanel Fire-Retardant B1 Aluminum composite panel (FR-ACP) is a product consisting of two sheets of
aluminum bonded to each side of a halogen-free fire-retardant polyethylene core. Panels are available in 4mm,
5mm, or 6mm thickness.
FLAME SPREAD RATINGS
Panel tested*
Test Flame Spread Smoke Development
Standard Index Index
ASTM E84 5 20
Core tested**
Test Flame Spread Smoke Development
Standard Index Index
ASTM E84 30 145
*Results based on 6.0mm thick panel. Flame spread rating only valid with exterior skin facing towards the flame.
**Results based on testing with one side of aluminum skin removed and core material facing towards the flame.
Tqneyat Al Alwah (Panels Technology Factory) - Technopanel | 41787 | Rev: Feb 23 2021 12:39PM | Uncontrolled Copy Page 2 of 2
CERT IFIC AT E OF COM PLIANCE
Certificate Number R40168
Report Reference R40168-2020-10-23
Date 2020-November-02
Issued to: TECHNOPANEL
MADAIN INDUSTRIAL 212 TO 217, NEW KHARJ ROAD,
P.O BOX 10342, RIYADH 11433
Riyadh, KSA SA
This is to certify that SHEATHING MATERIALS
representative samples of
“Technopanel – FR A2 Aluminium Composite Panel” 6mm
thick. 6mm thick product to give coverage for 4mm and
5mm thickness.
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: UL723, Standard for Surface Burning Characteristics for
Building Materials
Additional Information: See the UL Online Certifications Directory at
https://iq.ulprospector.com for additional information
This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.
Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.
Look for the UL Certification Mark on the product.
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
TECHNOPANEL FRPE‐ACP SPECIFICATION
I. Product Description
TECHNOPANEL Fire‐Retardant Aluminum Composite Panel (FR‐ACP) is a high performance
product consisting of two sheets of aluminum bonded to each side of a halogen‐free fire‐
retardant PE core. It is suitable to use for exterior and interior wall cladding applications or for
buildings under renovation that are designed to reduce the risk of structural fire. It has the
capability of reducing flame spread for a specified intensity and/or duration, low smoke and
delays heat penetration across on it.
II. Product Composition
TECHNOPANEL FR‐ACP is basically composed of the following materials:
PVDF Coating
Aluminum 0.5 mm
Fire Retardant Polyethylene (FRPE) Core
Aluminum 0.5 mm
Polyester Coating
1. POLYVINYLIDENE DIFLUORIDE (PVDF) COATING – paint for the front aluminum sheet with
high non‐reactive and pure flouropolymer coating used in applications requiring the highest
purity, strength, resistance to solvents, acids, bases and heat, and low smoke generation during
a fire event. PVDF is not susceptible to attack by UV light, so the resin does not break down on
exposure to sunlight which gives a very high resistance to fading, chalking and long‐term
retention of gloss and color.
Note: For other test values on coating properties, do refer to page 4.
2. ALUMINUM SHEETS ‐ two sheets of aluminum that is bonded to each side of a fire retardant
polyethylene core. They have excellent tensile strength, yield strength and elongation rate and
with high resistance to corrosion.
Type of Alloy 3003
Thickness 0.50 mm
1
TECHNOPANEL FRPE‐ACP SPECIFICATION
3. HALOGEN‐FREE FIRE‐RETARDANT CORE – the main core of TECHNOPANEL FR‐ACP that it has
the capability of reducing flame spread for a specified intensity and/or duration, low smoke and
delays heat penetration across it. It acts as a thermal insulation barrier where the role is to turn
polymer into a char, which separates the flame from the material.
There are two important components that can be used as a fire retardant core for polymer
applications. These components decompose at high temperatures absorbing considerable
amounts of heat in the process. In addition to behaving as a fire retardant, it is very effective as
a smoke suppressant when applied to polymers such as polyethylene.
The two components are:
Mg (OH)2 Magnesium Hydroxide or AL (OH)3 Aluminum Hydroxide
In addition to the performance of the FRPE core, it is Halogen‐free that limits the use of
hazardous substances on the product. The drive for creating these products is associated with
the green movement as well as health concerns. When fire breaks out and harmful substances
contained in plastics are ignited, toxic fumes are released into the surrounding area. Therefore,
compliance with these directives is important in the preservation of life and the environment.
4. POLYESTER COATING – a seven micrometer (7µm) polyester‐based coating for the back
aluminum sheet that serves as an aid in protecting TECHNOPANEL FR‐ACP from risks of exposure
to corrosion on the back surface of the panel after installation.
5. PROTECTIVE FILM ‐ The decorative surface is being covered by an 80 micrometer thick self‐
adhesive protective film to protect it from scratch and any possible damages during processing,
storage and installation. It is composed of two layers, the White surface with TECHNOPANEL
logo on the outer side to deflect ultraviolet rays and the Black surface from the inner side to
prevent ultraviolet rays from penetrating the inner surface.
2
TECHNOPANEL FRPE‐ACP SPECIFICATION
III. Product Dimension
1. Thickness : 4 mm, 5mm and 6 mm
2. Width : 1240 mm
3. Length : 5800 mm
Provision: or under customer’s requirement between 2000 to 6000 mm.
Note: Technopanel’s standard stock is 5800 x 1240 mm (L x W).
4. Tolerances
Size Permissible Tolerance
Length ,mm ±3
Width, mm ±2
Thickness,mm ±0.2
Deviation of diagonal, mm ≤5
Out of straight at sides, mm/m ≤5
Warp, mm/m ≤5
IV. Surface Visual Quality
The appearance of decorative surface shall not have any damages, irregularities and
abnormalities. It shall be inspected in accordance with the appearance criteria for Aluminum
Composite Panel (Outside and Inside Cladding) with maximum allowable blemishes and defects
on the criteria.
V. Product Properties
1. Panel Weight Density
ACP Thickness (mm) Panel Weight (kg/sq.m)
4 6.90 ± 0.5
5 8.30 ± 0.5
6 9.70 ± 0.5
3
TECHNOPANEL FRPE‐ACP SPECIFICATION
2. Coating Performance
National / International Technopanel Actual and
Test Item
Standard Test Value
Coating Thickness,
≥25 µm 31 µm
ISO 2360/2003
If gloss ≥ 70, max permissible
deviation ≤ 5
Gloss Deviation,
60 ‐ 64
ISO 2813/1978 If gloss<70, max permissible
deviation ≤10
Color Deviation,
< 2.0 dE 0.6 dE
ASTM D2244‐07
Pencil Hardness,
≥HB 3H
ISO 15184/1998
Coating Flexibility,
≤2T 0T
ASTM D4145‐83
Adhesion Grade, in grid way: Grade 0 in grid way: Grade 0
ISO 2409/2007 in circle way: Grade 1 in circle way: Grade 1
Impact Resistance, No peel‐off,
ISO 6272‐2/2002 No peel‐off, no crack
no crack at 50 kg.cm
Abrasion Resistance,
ASTM D968‐05 ≥ 5 L/um ≥ 5.5 L/um
Hot Water Resistance, No color change, crack & peel‐
No color change, no crack &
ISO 2409/2007 off at 98~100C
no peel‐off
in 120 min
Stain Resistance,
ASTM D1308
Acid Resistance,
ASTM D1308‐02
Alkali Resistance,
ASTM D1308‐02 No Change No Change
Oil Resistance,
ASTM D1308‐02
Solvent (Cleaner)
Resistance,
ASTM D1308‐02
Brush Resistance,
ASTM D1308‐02 ≥10000 times of no change No change
Salt Fog Resistance,
ASTM B117‐07 No change No change
Aging and Weather
Resistance
Color Deviation ≤ 3.0 0.6
Gloss Retention Grad. ≥ Grade 2 Grade 2
Other Aging Performance Grade 0 Grade 0
4
TECHNOPANEL FRPE‐ACP SPECIFICATION
3. Mechanical Properties
National / International Technopanel Actual and
Test Item
Standard Test Value
Bending (Flexural)
Strength , >100 MPa 102 MPa
ASTM D790‐10
Bend Elastic (Flexural)
Module, >2.0 x 104 MPa 2.14 x 104 MPa
ASTM D790‐10
Shear Strength,
> 28.0 MPa 28.6 MPa
ASTM D732‐10
Tensile Strength,
40 MPa 42.3 MPa
ASTM D638‐10
Elongation Rate,
<18 % 4.1%
ASTM B557‐10
180 Degree Peeling
Strength, 7 N/mm 9.8 N/mm
ISO 8510‐2/2006
4. Thermal / Sound Properties
National / International Technopanel Actual and
Test Item
Standard Test Value
Coefficient of Thermal
Expansion, <4.0 x 10 ‐5 0C‐1 2.163 x 10‐5 0C‐1
ASTM D696‐08
Heat Deflection
Temperature, >105 0C 118.1 0C
ASTM D648‐07
Sound Transmission,
<32dB 28dB
ASTM E413‐04
5
TECHNOPANEL FRPE‐ACP SPECIFICATION
5. Fire Performance Properties
National / International Technopanel Actual and
Test Item
Standard Test Value
BS 476 Part 6: Fire Test on
Building Materials and
Class O Class O
Structures
(Fire Propagation)
BS 476 Part 7: Fire Test on
Building Materials and
Class 1 Class 1
Structures
(Surface Spread of Flame)
EN 13823
Reaction to Fire Tests for
Building Products.
Building Products Excluding For Compliance Compliant
Floorings Exposed to the
Thermal Attack by a Single
Burning Item
EN ISO 11925‐2
Reaction to fire tests ‐
Ignitability of Building
Products Subjected to
For Compliance Compliant
Direct Impingement of
Flame
Part 2: Single‐flame Source
Test
ASTM E84‐04 ‐ Smoke Develop Index
Passed
Surface Burning (less than 450)
Characteristics of Building ‐ Flame Spread Index
Passed
Materials (less than 25)
The data in the technical document are general information and Technopanel has the right to change due to product
changes, improvements and other factors pertaining to product performances and standard requirement.
Please contact us for further information:
TQNEYAT AL‐ALWAH FACTORY (TECHNOPANEL)
Technical Engineering Department
Riyadh‐New Kharj Road
Madaen Industrial Zone Building 212 – 217
P.O. Box 10342, Riyadh 11433
Tel: +966‐11‐2447755
Fax: +966‐11‐2429040
6