0% found this document useful (0 votes)
109 views8 pages

UL Compliance Certificate for Festo Valves

This certificate certifies that representative samples of Festo SE & Co. KG's electrically operated valves and components have been tested according to UL's requirements and comply with UL Standard 429. The certificate lists the specific product models that have been evaluated, including solenoid valves, pressure supply modules, manifolds, solenoid coils, and valve terminals. The certificate is subject to conditions of acceptability related to power source, installation location, and intended wiring of connectors.

Uploaded by

Sitanath Das
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views8 pages

UL Compliance Certificate for Festo Valves

This certificate certifies that representative samples of Festo SE & Co. KG's electrically operated valves and components have been tested according to UL's requirements and comply with UL Standard 429. The certificate lists the specific product models that have been evaluated, including solenoid valves, pressure supply modules, manifolds, solenoid coils, and valve terminals. The certificate is subject to conditions of acceptability related to power source, installation location, and intended wiring of connectors.

Uploaded by

Sitanath Das
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

CERTIFICATE OF COMPLIANCE

Certificate Number UL-US-L000667-4


Report Reference MH19482-20160323
Date 28-Jun-2021

Issued to: Festo SE & Co. KG


Ruiter Strasse 82 Esslingen
Germany 73734

This is to certify that YIOZ2 - Valves, Electrically Operated - Component


representative samples of
See Addendum Page for Product Designation(s).

Have been investigated by UL in accordance with the


component requirements in the Standard(s) indicated on
this Certificate. UL Recognized components are incomplete
in certain constructional features or restricted in
performance capabilities and are intended for installation in
complete equipment submitted for investigation to UL LLC.

Standard(s) for Safety: UL 429, 7th Ed., Issue Date: 2013-11-06, Revision Date:
2020-01-16

Additional Information: See the UL Online Certifications Directory at


https://iq.ulprospector.com for additional information

This Certificate of Compliance does not provide authorization to apply the UL Recognized Component Mark.
Only the UL Follow-Up Services Procedure provides authorization to apply the UL Mark.

Only those products bearing the UL Recognized Component Mark should be considered as being UL Certified
and covered under UL’s Follow-Up Services.

Look for the UL Recognized Component Mark on the product.


UL-US-L000667-4
MH19482-20160323

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number UL-US-L000667-4
Report Reference MH19482-20160323
Date 28-Jun-2021

This is to certify that representative samples of the product as specified on this certificate were tested according
to the current UL requirements

Model Category Description


Series VTUS, Cat. Nos VSNC, followed by F, may be Solenoid Valves series
followed by K or T, may be followed by C, followed by
B52, M32C, M52, P53C, P53E or P53U, may be
followed by M, may be followed by D, H or S, followed by
G14, N14, Q6, Q8, Q10, T14, T38 or T516, may be
followed by QN, U1 or U3, followed by F8, may be
followed by 1, 1A, 5 or 5A, may be followed by A1, B2,
C3 or K11, may be followed by S8, may be followed by
EX1, EX2, EX3 or EX4, may be followed by C1, U1 or
U4, may be followed by A, M or N, may be followed by +,
may be followed by G or GS, may be followed by CS or
SA, may be followed by any alphanumeric suffixes.
Series VTUS, Cat. Nos. VABF, followed by any Pressure Supply Module series
alphanumeric suffixes.
Series VTUS, Cat. Nos. VABM, followed by any Manifold series
alphanumeric suffixes
Series VTUS, Cat. Nos. VACS, followed by A, B or C, Solenoid Coil series
followed by A1, B2 or C1, followed by 1, 1A, 5 or 5A,
may be followed by EX2, EX2C or EX3, may be followed
by any alphanumeric suffixes
Series VTUS, Cat. Nos. VTUS, followed by any Valve Terminal
alphanumeric suffixes.
Series VTUS, Cat. Nos. VUVS, followed by L, may be Solenoid Valves series
followed by K or T, may be followed by H, followed by
20, 25 or 30, followed by B52, M32C, M32U, M52, P53C,
P53E, P53U, T32C, T32H or T32U, may be followed by
A, E, M or R, may be followed by Z, may be followed by
D, H or S, followed by M5, M7, U10, G12, G14, G18,
G34, G38, N12, N14, N18, N34, N38, N11, Q4, Q6, Q8,
Q10, Q12, T12, T14, T18, T38, T316, T516 or T532,
may be followed by A, B, or C, may be followed by QN,
U, U1, U3 or U5, may be followed by Q4, Q6, T18 or
T532, may be followed by L, may be followed by F7 or
F8, may be followed by 1, 1A, 5 or 5A, may be followed
by A1, B2, C1, K7, K8 or K9, may be followed by S8,
may be followed by LS, may be followed by EX2, may be
followed by F or W, may be followed by F, may be
followed by S1, S2 or S4, may be followed by C1, C2,
C3, C4, C5, CL1, CL2, CL3, CL4, CL5, G, GL or GS,

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number UL-US-L000667-4
Report Reference MH19482-20160323
Date 28-Jun-2021

may be followed by CS or SA, may be followed by any


alphanumeric suffixes.
Series VTUS, VACF, followed by A, B or C, followed by Solenoid Coil series
A1, B2 or C1, followed by 1, 1A, 5 or 5A, may be
followed by EX2, EX2C or EX3, may be followed by any
alphanumeric suffixes
Series VTUS, VUWS, followed by L, may be followed by Solenoid Valves series
K or T, may be followed by H, followed by 20, 25 or 30,
followed by B52, M32C, M32U, M52, P53C, P53E,
P53U, T32C, T32H or T32U, may be followed by A, E, M
or R, may be followed by Z, may be followed by D, H or
S, followed by M5, M7, U10, G12, G14, G18, G34, G38,
N12, N14, N18, N34, N38, N11, Q4, Q6, Q8, Q10, Q12,
T12, T14, T18, T38, T316, T516 or T532, may be
followed by A, B, or C, may be followed by QN, U, U1,
U3 or U5, may be followed by Q4, Q6, T18 or T532, may
be followed by L, may be followed by F7 or F8, may be
followed by 1, 1A, 5 or 5A, may be followed by A1, B2,
C1, K7, K8 or K9, may be followed by S8, may be
followed by LS, may be followed by EX2, may be
followed by F or W, may be followed by F, may be
followed by S1, S2 or S4, may be followed by C1, C2,
C3, C4, C5, CL1, CL2, CL3, CL4, CL5, G, GL or GS,
may be followed by CS or SA, may be followed by any
alphanumeric suffixes.

CONDITIONS OF ACCEPTABILITY:

In determining the acceptability of these valves in the end-use, the following shall be determined:

1. These valves have been evaluated for connection to an NEC Class 2 source only.

2. These valves are only intended for use in indoor-dry locations only.

3. The valve connectors are intended to be factory-wired only.

4. The suitability of the factory–wiring, including mating connectors, for secureness, and grounding of dead-
metal, shall be determined in the end-product.

5. These valves are intended for use in an ultimate electrical enclosure, and the need for an electrical enclosure
for the valves shall be determined in the end-product application.

6. These valves are intended for use in a suitable enclosure or mounted in a guarded and protected location
where the valve body will be protected against impact.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number UL-US-L000667-4
Report Reference MH19482-20160323
Date 28-Jun-2021

7. The suitability of the grounding/bonding connection shall be evaluated in the end-product application.

8. The suitability of the fluid connections to these valves, with respect to securement and leakage, are to be
determined in the end-product application.

9. These valves are intended to be used in conjunction with air-tubes with the following fittings designation:

Port Air tube diameter Size thread

M3, M5, M7, G1/8, G1/4, G3/8, G1/2,


1, 2, 3, 4, 5,
Diameter 3 mm to 22 mm, G3/4,
12, 14, 82,
Diameter 1/8” to 1” NPT1/8, NPT1/4, NPT3/8, NPT1/2,
84
NPT3/4, UNF5/32, UNF5/16

10. Valve Terminal series VTUS shall be comprised of the following:

Coil Type Coil Marking Solenoid Valve Solenoid Valve


Marking
VACF-A Related to MH19482 VUVS-L30 or VSNC Related to
(series VUVS) MH19482 (series
VACF)
VACF-B Related to MH19482 VUVS-L25 or Related to
(series VUVS or VSNC) VUVS-L30 or MH19482 (series
VSNC VACF)
VACS-C Related to MH19482 VUVS-L20 Related to
(series VUVS) MH19482 (series
VACS)

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number UL-CA-L000265-4
Report Reference MH19482-20160323
Date 28-Jun-2021

Issued to: Festo SE & Co. KG


Ruiter Strasse 82 Esslingen
Germany 73734

This is to certify that YIOZ8 - Valves, Electrically Operated Certified for Canada -
representative samples of Component
See Addendum Page for Product Designation(s).

Have been investigated by UL in accordance with the


component requirements in the Standard(s) indicated on
this Certificate. UL Recognized components are incomplete
in certain constructional features or restricted in
performance capabilities and are intended for installation in
complete equipment submitted for investigation to UL LLC.

Standard(s) for Safety: CSA C22.2 No. 139-2019, 5th Ed., Issued 1 Dec 2019

Additional Information: See the UL Online Certifications Directory at


https://iq.ulprospector.com for additional information

This Certificate of Compliance does not provide authorization to apply the UL Recognized Component Mark.
Only the UL Follow-Up Services Procedure provides authorization to apply the UL Mark.

Only those products bearing the UL Recognized Component Mark should be considered as being UL Certified
and covered under UL’s Follow-Up Services.

Look for the UL Recognized Component Mark on the product.


UL-CA-L000265-4
MH19482-20160323

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number UL-CA-L000265-4
Report Reference MH19482-20160323
Date 28-Jun-2021

This is to certify that representative samples of the product as specified on this certificate were tested according
to the current UL requirements

Model Category Description


Series VTUS, Cat. Nos VSNC, followed by F, may be Solenoid Valves series
followed by K or T, may be followed by C, followed by
B52, M32C, M52, P53C, P53E or P53U, may be
followed by M, may be followed by D, H or S, followed by
G14, N14, Q6, Q8, Q10, T14, T38 or T516, may be
followed by QN, U1 or U3, followed by F8, may be
followed by 1, 1A, 5 or 5A, may be followed by A1, B2,
C3 or K11, may be followed by S8, may be followed by
EX1, EX2, EX3 or EX4, may be followed by C1, U1 or
U4, may be followed by A, M or N, may be followed by +,
may be followed by G or GS, may be followed by CS or
SA, may be followed by any alphanumeric suffixes.
Series VTUS, Cat. Nos. VABF, followed by any Pressure Supply Module series
alphanumeric suffixes.
Series VTUS, Cat. Nos. VABM, followed by any Manifold series
alphanumeric suffixes
Series VTUS, Cat. Nos. VACS, followed by A, B or C, Solenoid Coil series
followed by A1, B2 or C1, followed by 1, 1A, 5 or 5A,
may be followed by EX2, EX2C or EX3, may be followed
by any alphanumeric suffixes
Series VTUS, Cat. Nos. VTUS, followed by any Valve Terminal
alphanumeric suffixes.
Series VTUS, Cat. Nos. VUVS, followed by L, may be Solenoid Valves series
followed by K or T, may be followed by H, followed by
20, 25 or 30, followed by B52, M32C, M32U, M52, P53C,
P53E, P53U, T32C, T32H or T32U, may be followed by
A, E, M or R, may be followed by Z, may be followed by
D, H or S, followed by M5, M7, U10, G12, G14, G18,
G34, G38, N12, N14, N18, N34, N38, N11, Q4, Q6, Q8,
Q10, Q12, T12, T14, T18, T38, T316, T516 or T532,
may be followed by A, B, or C, may be followed by QN,
U, U1, U3 or U5, may be followed by Q4, Q6, T18 or
T532, may be followed by L, may be followed by F7 or
F8, may be followed by 1, 1A, 5 or 5A, may be followed
by A1, B2, C1, K7, K8 or K9, may be followed by S8,
may be followed by LS, may be followed by EX2, may be
followed by F or W, may be followed by F, may be
followed by S1, S2 or S4, may be followed by C1, C2,
C3, C4, C5, CL1, CL2, CL3, CL4, CL5, G, GL or GS,

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number UL-CA-L000265-4
Report Reference MH19482-20160323
Date 28-Jun-2021

may be followed by CS or SA, may be followed by any


alphanumeric suffixes.
Series VTUS, VACF, followed by A, B or C, followed by Solenoid Coil series
A1, B2 or C1, followed by 1, 1A, 5 or 5A, may be
followed by EX2, EX2C or EX3, may be followed by any
alphanumeric suffixes
Series VTUS, VUWS, followed by L, may be followed by Solenoid Valves series
K or T, may be followed by H, followed by 20, 25 or 30,
followed by B52, M32C, M32U, M52, P53C, P53E,
P53U, T32C, T32H or T32U, may be followed by A, E, M
or R, may be followed by Z, may be followed by D, H or
S, followed by M5, M7, U10, G12, G14, G18, G34, G38,
N12, N14, N18, N34, N38, N11, Q4, Q6, Q8, Q10, Q12,
T12, T14, T18, T38, T316, T516 or T532, may be
followed by A, B, or C, may be followed by QN, U, U1,
U3 or U5, may be followed by Q4, Q6, T18 or T532, may
be followed by L, may be followed by F7 or F8, may be
followed by 1, 1A, 5 or 5A, may be followed by A1, B2,
C1, K7, K8 or K9, may be followed by S8, may be
followed by LS, may be followed by EX2, may be
followed by F or W, may be followed by F, may be
followed by S1, S2 or S4, may be followed by C1, C2,
C3, C4, C5, CL1, CL2, CL3, CL4, CL5, G, GL or GS,
may be followed by CS or SA, may be followed by any
alphanumeric suffixes.

CONDITIONS OF ACCEPTABILITY:

In determining the acceptability of these valves in the end-use, the following shall be determined:

1. These valves have been evaluated for connection to an NEC Class 2 source only.

2. These valves are only intended for use in indoor-dry locations only.

3. The valve connectors are intended to be factory-wired only.

4. The suitability of the factory–wiring, including mating connectors, for secureness, and grounding of dead-
metal, shall be determined in the end-product.

5. These valves are intended for use in an ultimate electrical enclosure, and the need for an electrical enclosure
for the valves shall be determined in the end-product application.

6. These valves are intended for use in a suitable enclosure or mounted in a guarded and protected location
where the valve body will be protected against impact.

7. The suitability of the grounding/bonding connection shall be evaluated in the end-product application.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number UL-CA-L000265-4
Report Reference MH19482-20160323
Date 28-Jun-2021

8. The suitability of the fluid connections to these valves, with respect to securement and leakage, are to be
determined in the end-product application.

9. These valves are intended to be used in conjunction with air-tubes with the following fittings designation:

Port Air tube diameter Size thread

M3, M5, M7, G1/8, G1/4, G3/8, G1/2,


1, 2, 3, 4, 5,
Diameter 3 mm to 22 mm, G3/4,
12, 14, 82,
Diameter 1/8” to 1” NPT1/8, NPT1/4, NPT3/8, NPT1/2,
84
NPT3/4, UNF5/32, UNF5/16

10. Valve Terminal series VTUS shall be comprised of the following:

Coil Type Coil Marking Solenoid Valve Solenoid Valve


Marking
VACF-A Related to MH19482 VUVS-L30 or VSNC Related to
(series VUVS) MH19482 (series
VACF)
VACF-B Related to MH19482 VUVS-L25 or Related to
(series VUVS or VSNC) VUVS-L30 or MH19482 (series
VSNC VACF)
VACS-C Related to MH19482 VUVS-L20 Related to
(series VUVS) MH19482 (series
VACS)

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

You might also like