Beam Design ( Known Actual Moment)
* Assumption : Beam is tension controlled
Max Moment Applied = 0 kN.m
beam width , b = 350 mm
overall depth , h = 592.5 mm
concrete cover , cc 40 mm
effective depth, d = 540 mm
Ø = 25 mm
Area of steel is code compliant
n = 5 pcs
f'c (compressive strength of concrete) = 24 mPa
f'y (yield strength of steel) = 340 mPa
B = 0.85
Þmax 0.0244
Þact 0.0130
Þmin 0.0041
w 0.1840
Ru 3.9360
Mcap > > > 361.54 kN.m the beam is adequte
A's provided > > > 2454.369261 mm²
1 way slab design ( Known Actual Moment / Live Load)
* Assumption :
Simplyy supported
Beam is tension controlled
1m linear strip analyzed
Live Load = 4 kPa
f'c (compressive strength of concrete) = 20.7 mPa
f'y (yield strength of steel) = 275 mPa
Clear Span = 3000 mm
hmin = 118.928571428571 mm
Main bar diameter = 12 mm
hmin = 119 mm
concrete cover , cc 20 mm
effective depth, d = 93 mm
Ultimate Load 10721.764 N/m
Maximum Factored Moment: 12061.9845 N.m
Main bars:
Use 12.00 mm-Ø @
Governing Spacing 205 mm spaced @o.c.
Temp bars:
Ø = 10 mm
Use 10.00 mm-Ø @
Governing Spacing 329 mm spaced @o.c.
Design
Moment = 670 kN.m
f'c = 20.7 mPa
f'y = 345 mPa
b = 350 mm
h = 650 mm
top cover = 60 mm
bott cover = 50 mm
ß = 0.85
Þmax = 0.021
w = 0.344
R = 5.676
Mucap = 643.675 kN.m
design as doubly reinforced beam
Moment = 670 kN.m
f'c = 20.7 mPa
f'y = 345 mPa
b = 350 mm
h = 650 mm
top cover (d') = 60 mm
bott cover = 50 mm
As1 = 4335 mm²
a = 242.857142857143 mm
c = 285.714285714286 mm
f's = 474 mPa
compression steel will yield,use A's=As2
As2 = 157.004 mm²
As (tension side) = 4492.004 mm²
As (tension side)prov 4492.004 mm²
A's (compression side) = 157.004 mm²
A's (compression side)prov 226.190 mm²
Tension side
Ø 25 mm
n 9 pcs
Compression side
Ø 12 mm
n 2 pcs